1
|
Monistero V, Vicari N, Prati P, Bragoni R, Gazzola A, Sala L, Maisano A, Moroni P, Bronzo V, Luini MV, Castiglioni B, Cremonesi P. A rapid and reliable method for early Legionella pneumophila identification and characterization in support of the epidemiology study. Front Microbiol 2024; 15:1452861. [PMID: 39439937 PMCID: PMC11495126 DOI: 10.3389/fmicb.2024.1452861] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2024] [Accepted: 09/17/2024] [Indexed: 10/25/2024] Open
Abstract
Introduction Legionnaires' disease is a severe pneumonia predominantly caused by Legionella pneumophila (Lp), whose major reservoirs are artificial water systems. As most human infections are caused by L. pneumophila serogroup 1 (Lp1), a reliable method for Lp distinction can be crucial for bacterial spread prevention. As the ability to withstand in environments and to cause the waterborne disease is strongly related to specific genes, the identification of virulent strains can be of great relevance to implement water environmental monitoring and to contain harmful outbreaks to public health. We aimed to test an assay for Lp identification among different Legionella species, and to determine the serogroups. Additionally, we investigated the carriage of virulence and antimicrobial resistance genes. Methods A total of 90 Legionella spp. isolates identified by phenotypic tests were subjected to the designed quantitative PCR assay targeting specific mip for Lp, wzm for Lp1, pvcA and ahpD for biofilm production. Eleven serogroups were investigated in all our isolates tested positive for mip gene, subsequently analyzed for 12 virulence and 8 antimicrobial resistance genes. Results Only the 70 Lp isolates were positive for mip. Out of 27 Lp isolates belonging to serogroup 1 based on agglutination test, 23 (85.2%) carried wzm. The presence of ahpD and pvcA was found in 94.3 and 98.6% of Lp isolates, respectively. By multiplex PCR, all 23 wzm-positive strains were confirmed as serogroup 1 that was the most predominant (33%). At least one virulence gene was detected in all Lp isolates. The most frequent gene was ispE (100%), followed by issD (96%), icmK and enhC (93%), cpxA (91%), rtxA2 (74%), lvhB8-B9 (61%), and prpA (54%). The other genes were less diffused in Lp strains (rtxA1, 44%; lvhB3-B4, 47%; pvcB, 27%; lvrE, 24%). Of the macrolide resistance genes, the ereA was found in 84% of Lp strains, while only 14 (20%) harbored the lpeAB among the efflux pump genes. Conclusion The assays validated in this study enable the simultaneous Lp and Lp1 detection. The differentiation of Lp strains according to their virulence properties could be useful to predict the bacterial ability to survive and to cause the disease.
Collapse
Affiliation(s)
- Valentina Monistero
- Department of Veterinary Medicine and Animal Sciences - DIVAS, University of Milan, Lodi, Italy
- Laboratorio di Malattie Infettive degli Animali - MiLab, University of Milan, Lodi, Italy
| | - Nadia Vicari
- Diagnostic Section of Pavia, Istituto Zooprofilattico Sperimentale della Lombardia e dell’Emilia-Romagna - IZSLER, Pavia, Italy
| | - Paola Prati
- Diagnostic Section of Pavia, Istituto Zooprofilattico Sperimentale della Lombardia e dell’Emilia-Romagna - IZSLER, Pavia, Italy
| | - Roldano Bragoni
- Diagnostic Section of Pavia, Istituto Zooprofilattico Sperimentale della Lombardia e dell’Emilia-Romagna - IZSLER, Pavia, Italy
| | - Alessandra Gazzola
- Diagnostic Section of Lodi, Istituto Zooprofilattico Sperimentale della Lombardia e dell’Emilia-Romagna - IZSLER, Lodi, Italy
| | - Lorenza Sala
- Diagnostic Section of Lodi, Istituto Zooprofilattico Sperimentale della Lombardia e dell’Emilia-Romagna - IZSLER, Lodi, Italy
| | - Antonio Maisano
- Diagnostic Section of Lodi, Istituto Zooprofilattico Sperimentale della Lombardia e dell’Emilia-Romagna - IZSLER, Lodi, Italy
| | - Paolo Moroni
- Department of Veterinary Medicine and Animal Sciences - DIVAS, University of Milan, Lodi, Italy
- Laboratorio di Malattie Infettive degli Animali - MiLab, University of Milan, Lodi, Italy
| | - Valerio Bronzo
- Department of Veterinary Medicine and Animal Sciences - DIVAS, University of Milan, Lodi, Italy
- Laboratorio di Malattie Infettive degli Animali - MiLab, University of Milan, Lodi, Italy
| | - Mario Vittorio Luini
- Institute of Agricultural Biology and Biotechnology – IBBA-CNR, National Research Council, Lodi, Italy
| | - Bianca Castiglioni
- Institute of Agricultural Biology and Biotechnology – IBBA-CNR, National Research Council, Lodi, Italy
| | - Paola Cremonesi
- Institute of Agricultural Biology and Biotechnology – IBBA-CNR, National Research Council, Lodi, Italy
| |
Collapse
|
2
|
MASSOLO LUCIA, OGLIASTRO MATILDE, POSTMA PETER, FERRANTE ORIANA, AMATO ROSA, MASSARO ELVIRA, BELLINA DOROTEA, ZIFERRO ROBERTO, BORNETO ALBERTO, MORANDO ALESSANDRA, ORSI ANDREA. Environmental Surveillance of Legionella spp. in an Italian University Hospital: results of 7 years of analysis. JOURNAL OF PREVENTIVE MEDICINE AND HYGIENE 2024; 65:E166-E171. [PMID: 39430978 PMCID: PMC11487725 DOI: 10.15167/2421-4248/jpmh2024.65.2.3195] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 10/22/2024]
Abstract
Introduction Nosocomial structures pose a high risk of Legionella spp. contamination due to complex water systems with challenging disinfection; moreover, the risk of severe legionellosis as a consequence of nosocomial exposure is very high in settings characterized by vulnerable patient conditions. Methods In the present work, we described the results of 7 years of environmental surveillance in a reference hospital in Liguria, in which a specific water safety plan (WSP) has been implemented in 2017, including data collected during the COVID-19 pandemic. Results During the study period, 1190 water samples were collected, of which 277 (23.3%) tested positive for Legionella spp. Positive samples with concentration values above 1,000 CFU/l were 184 (66.4%). Based on the new structure categorization contained in the WSP, hospital buildings classified as at "very high" risk resulted the most affected structures over the entire study period; however, the absolute number of positive samples greatly decreased over time, from 61 contaminated water samples in 2017 to only 9 in 2023. Conclusions Our findings prompted the reinforcement of control and prevention measures, affirming the appropriateness of risk-category classification. Indeed, the majority of contamination cases were associated with the water networks of buildings classified as "very high" risk.
Collapse
Affiliation(s)
- LUCIA MASSOLO
- Department of Health Sciences, University of Genoa, Genoa, Italy
| | | | - PETER POSTMA
- Department of Health Sciences, University of Genoa, Genoa, Italy
| | - ORIANA FERRANTE
- Department of Health Sciences, University of Genoa, Genoa, Italy
| | - ROSA AMATO
- Department of Health Sciences, University of Genoa, Genoa, Italy
| | - ELVIRA MASSARO
- Department of Health Sciences, University of Genoa, Genoa, Italy
| | - DOROTEA BELLINA
- Hygiene Unit, IRCCS Policlinico San Martino Hospital, Genoa, Italy
| | - ROBERTO ZIFERRO
- Hygiene Unit, IRCCS Policlinico San Martino Hospital, Genoa, Italy
| | - ALBERTO BORNETO
- Technical Activities Operational Unit, IRCCS Policlinico San Martino Hospital, Genoa, Italy
| | | | - ANDREA ORSI
- Department of Health Sciences, University of Genoa, Genoa, Italy
- Hygiene Unit, IRCCS Policlinico San Martino Hospital, Genoa, Italy
| |
Collapse
|
3
|
Caruso G, Coniglio MA, Laganà P, Fasciana T, Arcoleo G, Arrigo I, Di Carlo P, Palermo M, Giammanco A. Validation of a Loop-Mediated Isothermal Amplification-Based Kit for the Detection of Legionella pneumophila in Environmental Samples According to ISO/TS 12869:2012. Microorganisms 2024; 12:961. [PMID: 38792790 PMCID: PMC11124444 DOI: 10.3390/microorganisms12050961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Revised: 04/20/2024] [Accepted: 04/22/2024] [Indexed: 05/26/2024] Open
Abstract
Legionella pneumophila is a freshwater opportunistic pathogen and the leading cause of severe pneumonia known as Legionnaires' disease. It can be found in all water systems and survives in biofilms, free-living amoebae, and a wide variety of facilities, such as air conditioning and showers in hospitals, hotels and spas. The reference cultural method allows for the isolation and identification in many days, and in addition, it does not detect viable but rather non-culturable bacteria, increasing the risk of infection. In this context, a new LAMP-based (loop-mediated isothermal amplification) kit was developed, allowing for the rapid, sensitive, and labor-saving detection of L. pneumophila. The kit, "Legionella pneumophila Glow", was validated according to ISO/TS 12869:2012, testing sensitivity, inclusivity and exclusivity, and kit robustness. Sensitivity showed that the "Legionella pneumophila Glow" kit can detect up to 28 plasmid copies/µL. Robustness tests showed consistent results, with both contamination levels and the matrices used giving reproducible results. Furthermore, real samples were evaluated to compare the performance of the two methods. The LAMP kit "Legionella pneumophila Glow" proved a useful option for the rapid, efficient, and labor-saving screening of different typologies of water samples, offering significant advantages over the traditional method, as it is characterized by a high sensitivity, ease of use for laboratory testing, and a large reduction in analysis time, making it an asset to official controls.
Collapse
Affiliation(s)
- Giorgia Caruso
- U.O.C. of Microbiology and Virology, ARNAS “Civico Di Cristina and Benfratelli”, 90127 Palermo, Italy
| | - Maria Anna Coniglio
- Legionella Reference Laboratory, Department of Medical, Surgical Sciences and Advanced Technologies “G.F. Ingrassia”, University of Catania, Via Santa Sofia 87, 95123 Catania, Italy;
- Hygiene Complex Operative Unit, A.O.U. Policlinico—Vittorio Emanuele, Via S. Sofia 87, 95123 Catania, Italy
| | - Pasqualina Laganà
- Legionella Reference Laboratory, University of Messina, 98125 Messina, Italy;
- Department of Biomedical and Dental Sciences and Morphofunctional Imaging, University of Messina, 98125 Messina, Italy
| | - Teresa Fasciana
- Legionella Reference Laboratory, University of Palermo, 90127 Palermo, Italy; (I.A.); (A.G.)
- Department of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialties, University of Palermo, 90127 Palermo, Italy;
| | | | - Ignazio Arrigo
- Legionella Reference Laboratory, University of Palermo, 90127 Palermo, Italy; (I.A.); (A.G.)
| | - Paola Di Carlo
- Department of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialties, University of Palermo, 90127 Palermo, Italy;
| | - Mario Palermo
- Sicilian Health Department, Public Health and Environmental Risks Service, 90127 Palermo, Italy;
| | - Anna Giammanco
- Legionella Reference Laboratory, University of Palermo, 90127 Palermo, Italy; (I.A.); (A.G.)
- Department of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialties, University of Palermo, 90127 Palermo, Italy;
| |
Collapse
|
4
|
Kowalczyk B, Petzold M, Kaczyński Z, Szuster-Ciesielska A, Luchowski R, Gruszecki WI, Fuchs B, Galuska CE, Choma A, Tarasiuk J, Palusińska-Szysz M. Lipopolysaccharide of Legionella pneumophila Serogroup 1 Facilitates Interaction with Host Cells. Int J Mol Sci 2023; 24:14602. [PMID: 37834049 PMCID: PMC10572746 DOI: 10.3390/ijms241914602] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 09/22/2023] [Accepted: 09/23/2023] [Indexed: 10/15/2023] Open
Abstract
Legionella pneumophila is the primary causative agent of Legionnaires' disease. The mutant-type strain interrupted in the ORF7 gene region responsible for the lipopolysaccharide biosynthesis of the L. pneumophila strain Heysham-1, lacking the O-acetyl groups attached to the rhamnose of the core part, showed a higher surface polarity compared with the wild-type strain. The measurement of excitation energy transfer between fluorophores located on the surface of bacteria and eukaryotic cells showed that, at an early stage of interaction with host cells, the mutant exhibited weaker interactions with Acanthamoeba castellanii cells and THP-1-derived macrophages. The mutant displayed reduced adherence to macrophages but enhanced adherence to A. castellanii, suggesting that the O-acetyl group of the LPS core region plays a crucial role in facilitating interaction with macrophages. The lack of core rhamnose O-acetyl groups made it easier for the bacteria to multiply in amoebae and macrophages. The mutant induced TNF-α production more strongly compared with the wild-type strain. The mutant synthesized twice as many ceramides Cer(t34:0) and Cer(t38:0) than the wild-type strain. The study showed that the internal sugars of the LPS core region of L. pneumophila sg 1 can interact with eukaryotic cell surface receptors and mediate in contacting and attaching bacteria to host cells as well as modulating the immune response to infection.
Collapse
Affiliation(s)
- Bożena Kowalczyk
- Department of Genetics and Microbiology, Institute of Biological Sciences, Faculty of Biology and Biotechnology, Maria Curie-Sklodowska University, 20-033 Lublin, Poland; (B.K.); (A.C.); (J.T.)
| | - Markus Petzold
- Institute of Medical Microbiology and Virology, University Hospital Carl Gustav Carus, University of Technology Dresden, 01069 Dresden, Germany;
| | - Zbigniew Kaczyński
- Laboratory of Structural Biochemistry, Faculty of Chemistry, University of Gdansk, 80-309 Gdansk, Poland;
| | - Agnieszka Szuster-Ciesielska
- Department of Virology and Immunology, Institute of Biological Sciences, Faculty of Biology and Biotechnology, Maria Curie-Sklodowska University, 20-033 Lublin, Poland;
| | - Rafał Luchowski
- Department of Biophysics, Institute of Physics, Faculty of Mathematics, Physics and Computer Science, Maria Curie-Sklodowska University, 20-031 Lublin, Poland; (R.L.); (W.I.G.)
| | - Wiesław I. Gruszecki
- Department of Biophysics, Institute of Physics, Faculty of Mathematics, Physics and Computer Science, Maria Curie-Sklodowska University, 20-031 Lublin, Poland; (R.L.); (W.I.G.)
| | - Beate Fuchs
- Research Institute for Farm Animal Biology (FBN), Core Facility Metabolomics, 18196 Dummerstorf, Germany; (B.F.); (C.E.G.)
| | - Christina E. Galuska
- Research Institute for Farm Animal Biology (FBN), Core Facility Metabolomics, 18196 Dummerstorf, Germany; (B.F.); (C.E.G.)
| | - Adam Choma
- Department of Genetics and Microbiology, Institute of Biological Sciences, Faculty of Biology and Biotechnology, Maria Curie-Sklodowska University, 20-033 Lublin, Poland; (B.K.); (A.C.); (J.T.)
| | - Jacek Tarasiuk
- Department of Genetics and Microbiology, Institute of Biological Sciences, Faculty of Biology and Biotechnology, Maria Curie-Sklodowska University, 20-033 Lublin, Poland; (B.K.); (A.C.); (J.T.)
| | - Marta Palusińska-Szysz
- Department of Genetics and Microbiology, Institute of Biological Sciences, Faculty of Biology and Biotechnology, Maria Curie-Sklodowska University, 20-033 Lublin, Poland; (B.K.); (A.C.); (J.T.)
| |
Collapse
|
5
|
Fasciana T, Palermo M, Arrigo I, Tricoli MR, Diquattro O, Giammanco A. Editorial: Special Issue: " Legionella pneumophila: A Microorganism with a Thousand Faces". Microorganisms 2023; 11:2392. [PMID: 37894050 PMCID: PMC10609420 DOI: 10.3390/microorganisms11102392] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2023] [Revised: 09/04/2023] [Accepted: 09/06/2023] [Indexed: 10/29/2023] Open
Abstract
Legionella pneumophila is a microorganism that is able to contaminate the freshwater environment and, consequently, human-made water systems [...].
Collapse
Affiliation(s)
- Teresa Fasciana
- Department of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialities, University of Palermo, 90127 Palermo, Italy;
- Legionella Reference Laboratory, University of Palermo, 90127 Palermo, Italy; (I.A.); (M.R.T.)
| | - Mario Palermo
- Sicilian Health Department, Public Health and Environmental Risks Service, 90127 Palermo, Italy;
| | - Ignazio Arrigo
- Legionella Reference Laboratory, University of Palermo, 90127 Palermo, Italy; (I.A.); (M.R.T.)
| | - Maria Rita Tricoli
- Legionella Reference Laboratory, University of Palermo, 90127 Palermo, Italy; (I.A.); (M.R.T.)
| | - Orazia Diquattro
- Laboratory of Microbiology, A. O. Ospedali Riuniti “Villa Sofia-Cervello”, 90100 Palermo, Italy;
| | - Anna Giammanco
- Department of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialities, University of Palermo, 90127 Palermo, Italy;
- Legionella Reference Laboratory, University of Palermo, 90127 Palermo, Italy; (I.A.); (M.R.T.)
| |
Collapse
|
6
|
Gea-Izquierdo E, Gil-Prieto R, Hernández-Barrera V, Rodríguez-Caravaca G, Gil-de-Miguel Á. Legionellosis-Associated Hospitalization in Spain from 2002 to 2021. Microorganisms 2023; 11:1693. [PMID: 37512866 PMCID: PMC10385138 DOI: 10.3390/microorganisms11071693] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Revised: 06/23/2023] [Accepted: 06/27/2023] [Indexed: 07/30/2023] Open
Abstract
Legionellosis is a respiratory disease of bacterial and environmental origin that usually presents two distinct clinical entities, "Legionnaires' disease" (LD) and "Pontiac fever". LD is an important cause of hospital-acquired pneumonia (HAP). The objective of this study is to describe the epidemiology of legionellosis-associated hospitalization (L-AH) in Spain from 2002 to 2021 and the burden of hospitalization due to legionellosis. Discharge reports from the Minimum Basic Data Set (MBDS) were used to retrospectively analyze hospital discharge data with a diagnosis of legionellosis, based on the ICD-9-CM and ICD-10-CM diagnosis codes, from 2002 to 2021. 21,300 L-AH occurred throughout the year during 2002-2021. The incidence of hospitalization associated per 100,000 inhabitants by month showed a similar trend for the 2002-2011, 2012-2021, and 2002-2021 periods. In Spain, during 2002-2021, the hospitalization rate (HR) in the autonomous communities ranged from 4.57 (2002-2011) to 0.24 (2012-2021) cases per 100,000 inhabitants. The HR of legionellosis in Spain has substantially increased across the 2002-2021 period, and the estimate is consistent with available European data. It is considered that in-depth epidemiological surveillance studies of legionellosis and improvements in the prevention and control of the disease are required in Spain.
Collapse
Affiliation(s)
- Enrique Gea-Izquierdo
- Preventive Medicine and Public Health, Rey Juan Carlos University, 28922 Madrid, Spain
- María Zambrano Program, European Union, Spain
| | - Ruth Gil-Prieto
- Preventive Medicine and Public Health, Rey Juan Carlos University, 28922 Madrid, Spain
| | | | - Gil Rodríguez-Caravaca
- Preventive Medicine and Public Health, Rey Juan Carlos University, 28922 Madrid, Spain
- Department of Preventive Medicine, Hospital Universitario Fundación Alcorcón, Rey Juan Carlos University, 28922 Madrid, Spain
| | - Ángel Gil-de-Miguel
- Preventive Medicine and Public Health, Rey Juan Carlos University, 28922 Madrid, Spain
- CIBER of Respiratory Diseases (CIBERES), Instituto de Salud Carlos III, 28029 Madrid, Spain
| |
Collapse
|
7
|
Lombardi A, Borriello T, De Rosa E, Di Duca F, Sorrentino M, Torre I, Montuori P, Trama U, Pennino F. Environmental Monitoring of Legionella in Hospitals in the Campania Region: A 5-Year Study. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:ijerph20085526. [PMID: 37107807 PMCID: PMC10138562 DOI: 10.3390/ijerph20085526] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 04/06/2023] [Accepted: 04/13/2023] [Indexed: 05/11/2023]
Abstract
Legionella is a pathogen that colonizes soils, freshwater, and building water systems. People who are most affected are those with immunodeficiencies, so it is necessary to monitor its presence in hospitals. The purpose of this study was to evaluate the presence of Legionella in water samples collected from hospitals in the Campania region, Southern Italy. A total of 3365 water samples were collected from January 2018 to December 2022 twice a year in hospital wards from taps and showers, tank bottoms, and air-treatment units. Microbiological analysis was conducted in accordance with the UNI EN ISO 11731:2017, and the correlations between the presence of Legionella and water temperature and residual chlorine were investigated. In total, 708 samples (21.0%) tested positive. The most represented species was L. pneumophila 2-14 (70.9%). The serogroups isolated were 1 (27.7%), 6 (24.5%), 8 (23.3%), 3 (18.9%), 5 (3.1%), and 10 (1.1%). Non-pneumophila Legionella spp. represented 1.4% of the total. Regarding temperature, the majority of Legionella positive samples were found in the temperature range of 26.0-40.9 °C. An influence of residual chlorine on the presence of the bacterium was observed, confirming that chlorine disinfection is effective for controlling contamination. The positivity for serogroups other than serogroup 1 suggested the need to continue environmental monitoring of Legionella and to focus on the clinical diagnosis of other serogroups.
Collapse
Affiliation(s)
- Annalisa Lombardi
- Department of Public Health, University “Federico II”, Via Sergio Pansini N° 5, 80131 Naples, Italy
| | - Tonia Borriello
- Department of Public Health, University “Federico II”, Via Sergio Pansini N° 5, 80131 Naples, Italy
| | - Elvira De Rosa
- Department of Public Health, University “Federico II”, Via Sergio Pansini N° 5, 80131 Naples, Italy
| | - Fabiana Di Duca
- Department of Public Health, University “Federico II”, Via Sergio Pansini N° 5, 80131 Naples, Italy
| | - Michele Sorrentino
- Department of Public Health, University “Federico II”, Via Sergio Pansini N° 5, 80131 Naples, Italy
| | - Ida Torre
- Department of Public Health, University “Federico II”, Via Sergio Pansini N° 5, 80131 Naples, Italy
| | - Paolo Montuori
- Department of Public Health, University “Federico II”, Via Sergio Pansini N° 5, 80131 Naples, Italy
| | - Ugo Trama
- General Directorate of Health, Campania Region, Centro Direzionale C3, 80143 Naples, Italy
| | - Francesca Pennino
- Department of Public Health, University “Federico II”, Via Sergio Pansini N° 5, 80131 Naples, Italy
- Correspondence:
| |
Collapse
|
8
|
De Giglio O, D’Ambrosio M, Spagnuolo V, Diella G, Fasano F, Leone CM, Lopuzzo M, Trallo V, Calia C, Oliva M, Pazzani C, Iacumin L, Barigelli S, Petricciuolo M, Federici E, Lisena FP, Minicucci AM, Montagna MT. Legionella anisa or Legionella bozemanii? Traditional and molecular techniques as support in the environmental surveillance of a hospital water network. ENVIRONMENTAL MONITORING AND ASSESSMENT 2023; 195:496. [PMID: 36947259 PMCID: PMC10033568 DOI: 10.1007/s10661-023-11078-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Accepted: 03/02/2023] [Indexed: 06/18/2023]
Abstract
Understanding the actual distribution of different Legionella species in water networks would help prevent outbreaks. Culture investigations followed by serological agglutination tests, with poly/monovalent antisera, still represent the gold standard for isolation and identification of Legionella strains. However, also MALDI-TOF and mip-gene sequencing are currently used. This study was conducted to genetically correlate strains of Legionella non pneumophila (L-np) isolated during environmental surveillance comparing different molecular techniques. Overall, 346 water samples were collected from the water system of four pavilions located in a hospital of the Apulia Region of Italy. Strains isolated from the samples were then identified by serological tests, MALDI-TOF, and mip-gene sequencing. Overall, 24.9% of water samples were positive for Legionella, among which the majority were Legionella pneumophila (Lpn) 1 (52.3%), followed by Lpn2-15 (20.9%), L-np (17.4%), Lpn1 + Lpn2-15 (7.1%), and L-np + Lpn1 (2.3%). Initially, L-np strains were identified as L. bozemanii by monovalent antiserum, while MALDI-TOF and mip-gene sequencing assigned them to L. anisa. More cold water than hot water samples were contaminated by L. anisa (p < 0.001). PFGE, RAPD, Rep-PCR, and SAU-PCR were performed to correlate L. anisa strains. Eleven out of 14 strains identified in all four pavilions showed 100% of similarity upon PFGE analysis. RAPD, Rep-PCR, and SAU-PCR showed greater discriminative power than PFGE.
Collapse
Affiliation(s)
- Osvalda De Giglio
- Interdisciplinary Department of Medicine, Section of Hygiene, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124 Bari, Italy
| | - Marilena D’Ambrosio
- Department of Biomedical Sciences and Human Oncology, Section of Hygiene, Medical School, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124 Bari, Italy
| | - Valentina Spagnuolo
- Department of Biomedical Sciences and Human Oncology, Section of Hygiene, Medical School, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124 Bari, Italy
| | - Giusy Diella
- Interdisciplinary Department of Medicine, Section of Hygiene, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124 Bari, Italy
| | - Fabrizio Fasano
- Interdisciplinary Department of Medicine, Section of Hygiene, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124 Bari, Italy
| | - Carla Maria Leone
- Present Address: Section Hygiene - AOU Policlinico of Bari, Piazza G. Cesare 11, 70124 Bari, Italy
| | - Marco Lopuzzo
- Department of Biomedical Sciences and Human Oncology, Section of Hygiene, Medical School, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124 Bari, Italy
| | - Valeria Trallo
- Present Address: Section Hygiene - AOU Policlinico of Bari, Piazza G. Cesare 11, 70124 Bari, Italy
| | - Carla Calia
- Department of Biology, University of Bari Aldo Moro, Via Orabona 4, 70126 Bari, Italy
| | - Marta Oliva
- Department of Biology, University of Bari Aldo Moro, Via Orabona 4, 70126 Bari, Italy
| | - Carlo Pazzani
- Department of Biology, University of Bari Aldo Moro, Via Orabona 4, 70126 Bari, Italy
| | - Lucilla Iacumin
- Department of Agricultural, Food, Environmental and Animal Science, University of Udine, Via Sondrio 2/a, 33100 Udine, Italy
| | - Sofia Barigelli
- Department of Chemistry, Biology and Biotechnology, University of Perugia, Via del Giochetto, 06122 Perugia, Italy
| | - Maya Petricciuolo
- Department of Chemistry, Biology and Biotechnology, University of Perugia, Via del Giochetto, 06122 Perugia, Italy
| | - Ermanno Federici
- Department of Chemistry, Biology and Biotechnology, University of Perugia, Via del Giochetto, 06122 Perugia, Italy
| | | | - Anna Maria Minicucci
- Health Management, A.O.U. Policlinico of Bari, Piazza G. Cesare 11, 70124 Bari, Italy
| | - Maria Teresa Montagna
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Interdisciplinary Department of Medicine, Section of Hygiene, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124 Bari, Italy
| |
Collapse
|
9
|
Kanarek P, Bogiel T, Breza-Boruta B. Legionellosis risk-an overview of Legionella spp. habitats in Europe. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2022; 29:76532-76542. [PMID: 36161570 PMCID: PMC9511453 DOI: 10.1007/s11356-022-22950-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Accepted: 09/05/2022] [Indexed: 05/28/2023]
Abstract
An increase in the number of reports of legionellosis in the European Union and the European Economic Area have been recorded in recent years. The increase in cases is significant: from 6947 reports in 2015 to 11,298 in 2019. This is alarming as genus Legionella, which comprises a large group of bacteria inhabiting various aquatic systems, poses a serious threat to human health and life, since more than 20 species can cause legionellosis, with L. pneumophila being responsible for the majority of cases. The ability to colonize diverse ecosystems makes the eradication of these microorganisms difficult. A detailed understanding of the Legionella habitat may be helpful in the effective control of this pathogen. This paper provides an overview of Legionella environments in Europe: natural (lakes, groundwater, rivers, compost, soil) and anthropogenic (fountains, air humidifiers, water supply systems), and the role of Legionella spp. in nosocomial infections, which are potentially fatal for children, the elderly and immunocompromised patients.
Collapse
Affiliation(s)
- Piotr Kanarek
- Department of Microbiology and Food Technology, Faculty of Agriculture and Biotechnology, Bydgoszcz University of Science and Technology, 6 Bernardyńska Street, 85-029, Bydgoszcz, Poland
| | - Tomasz Bogiel
- Department of Microbiology, Ludwik Rydygier Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Toruń, 9 Skłodowska-Curie Street, 85-094, Bydgoszcz, Poland
| | - Barbara Breza-Boruta
- Department of Microbiology and Food Technology, Faculty of Agriculture and Biotechnology, Bydgoszcz University of Science and Technology, 6 Bernardyńska Street, 85-029, Bydgoszcz, Poland.
| |
Collapse
|
10
|
Gamage SD, Jinadatha C, Coppin JD, Kralovic SM, Bender A, Ambrose M, Decker BK, DeVries AS, Goto M, Kowalskyj O, Maistros AL, Rizzo V, Simbartl LA, Watson RJ, Roselle GA. Factors That Affect Legionella Positivity in Healthcare Building Water Systems from a Large, National Environmental Surveillance Initiative. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2022; 56:11363-11373. [PMID: 35929739 DOI: 10.1021/acs.est.2c02194] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Legionella growth in healthcare building water systems can result in legionellosis, making water management programs (WMPs) important for patient safety. However, knowledge is limited on Legionella prevalence in healthcare buildings. A dataset of quarterly water testing in Veterans Health Administration (VHA) healthcare buildings was used to examine national environmental Legionella prevalence from 2015 to 2018. Bayesian hierarchical logistic regression modeling assessed factors influencing Legionella positivity. The master dataset included 201,146 water samples from 814 buildings at 168 VHA campuses. Overall Legionella positivity over the 4 years decreased from 7.2 to 5.1%, with the odds of a Legionella-positive sample being 0.94 (0.90-0.97) times the odds of a positive sample in the previous quarter for the 16 quarters of the 4 year period. Positivity varied considerably more at the medical center campus level compared to regional levels or to the building level where controls are typically applied. We found higher odds of Legionella detection in older buildings (OR 0.92 [0.86-0.98] for each more recent decade of construction), in taller buildings (OR 1.20 [1.13-1.27] for each additional floor), in hot water samples (O.R. 1.21 [1.16-1.27]), and in samples with lower residual biocide concentrations. This comprehensive healthcare building review showed reduced Legionella detection in the VHA healthcare system over time. Insights into factors associated with Legionella positivity provide information for healthcare systems implementing WMPs and for organizations setting standards and regulations.
Collapse
Affiliation(s)
- Shantini D Gamage
- National Infectious Diseases Service, Specialty Care Program Office, Veterans Health Administration, Department of Veterans Affairs (VA), Washington, D.C. 20571, United States
- Division of Infectious Diseases, Department of Internal Medicine, University of Cincinnati College of Medicine, Cincinnati, Ohio 45267, United States
| | - Chetan Jinadatha
- Department of Medicine, Central Texas Veterans Health Care System, Temple, Texas 76504, United States
- College of Medicine, Texas A&M University, Bryan, Texas 77807, United States
| | - John D Coppin
- Department of Research, Central Texas Veterans Health Care System, Temple, Texas 76504, United States
| | - Stephen M Kralovic
- National Infectious Diseases Service, Specialty Care Program Office, Veterans Health Administration, Department of Veterans Affairs (VA), Washington, D.C. 20571, United States
- Division of Infectious Diseases, Department of Internal Medicine, University of Cincinnati College of Medicine, Cincinnati, Ohio 45267, United States
- Cincinnati VA Medical Center, Cincinnati, Ohio 45220, United States
| | - Alan Bender
- Booz Allen Hamilton, McLean, Virginia 22102, United States
| | - Meredith Ambrose
- National Infectious Diseases Service, Specialty Care Program Office, Veterans Health Administration, Department of Veterans Affairs (VA), Washington, D.C. 20571, United States
| | - Brooke K Decker
- Division of Infectious Diseases, VA Pittsburgh Healthcare System, Pittsburgh, Pennsylvania 15240, United States
| | - Aaron S DeVries
- Minneapolis VA Healthcare System, Minneapolis, Minnesota 55417, United States
| | - Michihiko Goto
- Iowa City VA Health Care System, Iowa City, Iowa 52246, United States
- University of Iowa Carver College of Medicine, Iowa City, Iowa 52242, United States
| | - Oleh Kowalskyj
- Office of Healthcare Engineering, Healthcare Environment and Facilities Program, Veterans Health Administration, VA, Washington, D.C. 20571, United States
| | - Angela L Maistros
- VA Capitol Health Care Network, Veterans Integrated Service Network (VISN) 5, Linthicum, Maryland 21090, United States
| | - Vincent Rizzo
- Office of Healthcare Engineering, Healthcare Environment and Facilities Program, Veterans Health Administration, VA, Washington, D.C. 20571, United States
| | - Loretta A Simbartl
- National Infectious Diseases Service, Specialty Care Program Office, Veterans Health Administration, Department of Veterans Affairs (VA), Washington, D.C. 20571, United States
| | - Richard J Watson
- Occupational Health and Safety Program Office, Veterans Health Administration, VA, Washington, D.C. 20571, United States
| | - Gary A Roselle
- National Infectious Diseases Service, Specialty Care Program Office, Veterans Health Administration, Department of Veterans Affairs (VA), Washington, D.C. 20571, United States
- Division of Infectious Diseases, Department of Internal Medicine, University of Cincinnati College of Medicine, Cincinnati, Ohio 45267, United States
- Cincinnati VA Medical Center, Cincinnati, Ohio 45220, United States
| |
Collapse
|
11
|
Rakić A, Vukić Lušić D, Jurčev Savičević A. Influence of Metal Concentration and Plumbing Materials on Legionella Contamination. Microorganisms 2022; 10:1051. [PMID: 35630493 PMCID: PMC9147233 DOI: 10.3390/microorganisms10051051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2022] [Revised: 05/15/2022] [Accepted: 05/17/2022] [Indexed: 12/07/2022] Open
Abstract
Legionella colonization of water supply pipes is a significant public health problem. The objective of this work was to evaluate Legionella colonization in hotel hot water systems and to investigate the relationship between metal concentrations, piping materials (galvanized iron pipes and plastic pipes), and Legionella proliferation. Concentrations of calcium and magnesium ions and the presence of Legionella pneumophila were determined in a total of 108 water samples from the hot water systems of four hotels in Split-Dalmatia County over a 12-month period, and additional data on piping materials were collected. L. pneumophila was isolated in 23.1% of all samples-in 28.8% (15/52) of water samples from galvanized iron pipes and in 17.8% (10/56) of samples from plastic pipes. L. pneumophila serogroups 2-14 were isolated from all samples. This study found higher prevalence of L. pneumophila at higher concentrations of Ca and Mg ions (except for Mg and plastic pipes). The metal parts of the water supply may be important factors in Legionella contamination due to the possibility of lime scale or roughness of the pipes. Higher Ca and Mg ion concentrations increased the risk of Legionella colonization.
Collapse
Affiliation(s)
- Anita Rakić
- Public Health Institute of Split-Dalmatia County, Vukovarska 46, 21000 Split, Croatia;
| | - Darija Vukić Lušić
- Department of Environmental Health, Faculty of Medicine, University of Rijeka, Braće Branchetta 20, 51000 Rijeka, Croatia
- Department of Environmental Health, Teaching Institute of Public Health of Primorje-Gorski Kotar County, Krešimirova 52a, 51000 Rijeka, Croatia
- Center for Advanced Computing and Modeling, University of Rijeka, Radmile Matejčić 2, 51000 Rijeka, Croatia
| | - Anamarija Jurčev Savičević
- Public Health Institute of Split-Dalmatia County, Vukovarska 46, 21000 Split, Croatia;
- Department of Health Studies, University of Split, 35 P.P. 464, Ruđera Boškovića Street, 21000 Split, Croatia
| |
Collapse
|