1
|
Tang H, Sun G, Xu Y, Men S, Jiang W, Wang C. Simultaneous determination of inflammatory factors SAA and LTF based on stable element labeling and inductively coupled plasma mass spectrometry to aid in the diagnosis of infection. J Immunol Methods 2024; 528:113666. [PMID: 38574805 DOI: 10.1016/j.jim.2024.113666] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2023] [Revised: 03/31/2024] [Accepted: 04/01/2024] [Indexed: 04/06/2024]
Abstract
OBJECTIVE The clinical value of Serum amyloid A (SAA) and Lactoferrin (LTF) has received significant attention, but their detection methods are inadequate, which limits their application. This study aims to develop a dual detection method based on stable element labeling strategies and inductively coupled plasma mass spectrometry (ICP-MS) for SAA/LTF and to assess whether it can be widely used in clinical practice. METHODS A duplex immunoassay system based on sandwich method was constructed. After optimization, methodological evaluation was performed with the guidelines of Clinical Laboratory Standards Institute (CLSI). Finally, 131 plasma samples were collected to analyze whether the new method is suitable for clinical detection. RESULTS The LoB, LLoQ, ULoQ, and linear range of the assay were 1.09 ng/mL, 3 ng/mL, 1500 ng/mL, 3-1500 ng/mL for SAA and 0.85 ng/mL, 2 ng/mL, 1200 ng/mL, 2-1200 ng/mL for LTF respectively. The recovery rates were 95.01% to 106.26%, the intra-batch precision of low, intermediate, and high-level samples was <8%, and the inter-batch of them was <11%, the deviation of interference test results was less than±10%. The Area Under the Curve (AUC) was 0.9809 for SAA, 0.8599 for LTF, and 0.9986 for combination. CONCLUSION The quantitative duplex immunoassay for SAA/LTF has high accuracy, good precision, and high specificity, which meets the clinical testing requirements and can be widely used in clinical practice.
Collapse
Affiliation(s)
- Hairong Tang
- Department of Laboratory Medicine, the first Medical Center, Chinese PLA General Hospital, Fuxing Road 28, Haidian District, Beijing 100853, China
| | - Gongwei Sun
- Beijing Key Laboratory for Microanalytical Methods and Instrumentation, Department of Chemistry, Tsinghua University, Shuangqing Road 30, Haidian District, Beijing 100084, China
| | - Ying Xu
- Department of Laboratory Medicine, the first Medical Center, Chinese PLA General Hospital, Fuxing Road 28, Haidian District, Beijing 100853, China
| | - Shasha Men
- Department of Laboratory Medicine, the first Medical Center, Chinese PLA General Hospital, Fuxing Road 28, Haidian District, Beijing 100853, China
| | - Wencan Jiang
- Department of Clinical Diagnosis, Laboratory of Beijing Tiantan Hospital and Capital Medical University, South Fourth Ring West Road 119, Fengtai District, Beijing 100070, China.
| | - Chengbin Wang
- Department of Laboratory Medicine, the first Medical Center, Chinese PLA General Hospital, Fuxing Road 28, Haidian District, Beijing 100853, China.
| |
Collapse
|
2
|
Cao D, Wu W, Huang X, Liu L, Wei Q, Cao W. Dual-signal ratiometric electrochemical immunosensor constructed with snowflake-like FeSe 2-AuNPs and PAA-ZIF@TB for sensitive detection of CYFRA21-1. Talanta 2023; 260:124632. [PMID: 37149935 DOI: 10.1016/j.talanta.2023.124632] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Revised: 04/28/2023] [Accepted: 05/02/2023] [Indexed: 05/09/2023]
Abstract
In this study, a ratiometric electrochemical immunosensor has been developed to detect the cytokeratin 19 fragment 21-1 (CYFRA21-1) biomarker in a highly sensitive manner through a dual-signal output model. As one of signal indicators, snowflake-like FeSe2 loaded with AuNPs (FeSe2-AuNPs) as sensing substrate with good conductivity and large active sites provides a differential pulse voltammetry (DPV) signal at +0.4 V. Another signal indicator, toluidine blue (TB) with the water-solubility property is an excellent redox probe that can generate DPV signal at -0.3 V. To solve the water-solubility problem, the TB is absorbed with polyacrylic acid (PAA) functionalized ZIF-67 (PAA-ZIF-67), which retains the properties of ZIF-67 that are large specific surface area and strong adsorption properties. The ratio of signals, stemmed from PAA-ZIF@TB and FeSe2-AuNPs (IPAA-ZIF@TB/IFeSe2-AuNPs), increases with the CYFRA21-1 concentration. Under optimal experimental conditions, CYFRA21-1 was detected in a wide dynamic range from 0.1 pg/mL to 100 ng/mL, with a lower limit of detection of 0.02 pg/mL. Looking ahead, this ratio based strategy provides prospective clinical applications for detecting other biomarkers.
Collapse
Affiliation(s)
- Dongmei Cao
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Wenrui Wu
- Qilu Pharmaceutical Co., LTD, Jinan 250105, PR China
| | - Xinyi Huang
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Lei Liu
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China.
| | - Qin Wei
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Wei Cao
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China.
| |
Collapse
|
3
|
Xu S, Liu H, Bai Y. Highly sensitive and multiplexed mass spectrometric immunoassay techniques and clinical applications. Anal Bioanal Chem 2022; 414:5121-5138. [PMID: 35165779 DOI: 10.1007/s00216-022-03945-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Revised: 01/17/2022] [Accepted: 01/31/2022] [Indexed: 11/29/2022]
Abstract
Immunoassay is one of the most important clinical techniques for disease/pathological diagnosis. Mass spectrometry (MS) has been a popular and powerful readout technique for immunoassays, generating the mass spectrometric immunoassays (MSIAs) with unbeatable channels for multiplexed detection. The sensitivity of MSIAs has been greatly improved with the development of mass labels from element labels to small-molecular labels. MSIAs are also expended from the representative element MS-based methods to the laser-based organic MS and latest ambient MS, improving in both technology and methodology. Various MSIAs present high potential for clinical applications, including the biomarker screening, the immunohistochemistry, and the advanced single-cell analysis. Here, we give an overall review of the development of MSIAs in recent years, highlighting the latest improvement of mass labels and MS techniques for clinical immunoassays.
Collapse
Affiliation(s)
- Shuting Xu
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, 214122, Jiangsu, China.,Beijing National Laboratory for Molecular Sciences, Key Laboratory of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, College of Chemistry and Molecular Engineering, Peking University, Beijing, 100871, China.,Institute of Analytical Food Safety, School of Food Science and Technology, Jiangnan University, Wuxi, 214122, Jiangsu, China
| | - Huwei Liu
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, College of Chemistry and Molecular Engineering, Peking University, Beijing, 100871, China
| | - Yu Bai
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, College of Chemistry and Molecular Engineering, Peking University, Beijing, 100871, China.
| |
Collapse
|
4
|
Xu Y, Zhang P, Zhang K, Huang C. The application of CA72-4 in the diagnosis, prognosis, and treatment of gastric cancer. Biochim Biophys Acta Rev Cancer 2021; 1876:188634. [PMID: 34656687 DOI: 10.1016/j.bbcan.2021.188634] [Citation(s) in RCA: 36] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2021] [Revised: 10/09/2021] [Accepted: 10/10/2021] [Indexed: 02/07/2023]
Abstract
The role of conventional serum tumor marker, carbohydrate antigen 72-4 (CA72-4), in assisting diagnosis, monitoring dynamic progression, and evaluating the prognosis of gastric cancer (GC) should not be ignored, especially in the Chinese population. Even though CA72-4 has been used in clinical practice for decades, its modest positivity rate, sensitivity, and specificity did not meet the high demand of the clinical application. However, over the years, some progress in the functions of CA72-4 has been achieved, suggesting that CA72-4 can still be considered a promising marker in oncology. As a biomarker, CA72-4 can achieve improved sensitivity (SEN) and specificity (SPE) when combined with other biomarkers, selecting suitable reference values, improving detection techniques, and identifying the risk threshold. As a predictor, elevated serum CA72-4 levels were found to be significantly associated with prognostic risk factors, further assessing therapeutic validity and resectability. Recently, an effective method to reduce the toxicity of CA72-4 targeted therapy has been developed. Moreover, CA72-4 could induce novel aptamers to react with tumor cells and enhance the efficacy of trastuzumab in HER2-positive GC. Therefore, in this review, we discuss the most recent application of CA72-4 in the diagnosis, prognosis, and treatment of GC.
Collapse
Affiliation(s)
- Yitian Xu
- Department of Gastrointestinal Surgery, Shanghai General Hospital Affiliated to Shanghai Jiaotong University, Shanghai 200080, PR China
| | - Pengshan Zhang
- Department of Gastrointestinal Surgery, Shanghai General Hospital Affiliated to Shanghai Jiaotong University, Shanghai 200080, PR China
| | - Kundong Zhang
- Department of Gastrointestinal Surgery, Shanghai General Hospital Affiliated to Shanghai Jiaotong University, Shanghai 200080, PR China
| | - Chen Huang
- Department of Gastrointestinal Surgery, Shanghai General Hospital Affiliated to Shanghai Jiaotong University, Shanghai 200080, PR China.
| |
Collapse
|
5
|
Tan X, Liu M, He K. Study of Long-Term Determination Accuracy for REEs in Geological Samples by Inductively Coupled Plasma Quadrupole Mass Spectrometry. Molecules 2021; 26:molecules26020290. [PMID: 33430078 PMCID: PMC7827012 DOI: 10.3390/molecules26020290] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Revised: 01/06/2021] [Accepted: 01/06/2021] [Indexed: 11/19/2022] Open
Abstract
This work presents the long-term determination accuracy study of ICP-QMS for rare earth elements (REEs) in geological matrices. Following high-pressure closed acidic decomposition, REEs are measured repetitively across seven months by ICP-QMS. Under optimum experimental conditions (including spray chamber temperature, gas flow rate, sampling depth, etc.), the REE contents in geological standard materials from basic (basalt BCR-2 and BE-N) to intermediate (andesite AGV-2) and up to acidic (granite GSR-1) show good agreement with the certified values, giving relative errors below 10%. Here, the influence of two storage materials (perfluoroalkoxy PFA and polypropylene PP) on the long-term determination accuracy of REEs has also been monitored. It is found that the relative errors of REEs using a PFA container range from −6.6 to 6.3% (RSDs < 6.0%), while that using a PP container are within −4.0 to 3.9% (RSDs < 4.6%). By using PP material as a solution storage container, the accuracy of REEs quantification in a series of real geological samples are checked, showing the RSDs of less than 5.0%. This work first clarifies the long-term stability of REEs quantification by ICP-QMS covering two types of storage materials, confirming the reasonability of PP material as a daily storage container in terms of higher data precision and lower cost.
Collapse
Affiliation(s)
- Xijuan Tan
- Laboratory of Mineralization and Dynamics, Chang’an University, 126 Yanta Road, Xi’an 710054, China; (M.L.); (K.H.)
- College of Earth Sciences and Land Resources, Chang’an University, 126 Yanta Road, Xi’an 710054, China
- Correspondence: ; Tel.: +86-029-8233-9067
| | - Minwu Liu
- Laboratory of Mineralization and Dynamics, Chang’an University, 126 Yanta Road, Xi’an 710054, China; (M.L.); (K.H.)
- College of Earth Sciences and Land Resources, Chang’an University, 126 Yanta Road, Xi’an 710054, China
| | - Ke He
- Laboratory of Mineralization and Dynamics, Chang’an University, 126 Yanta Road, Xi’an 710054, China; (M.L.); (K.H.)
- College of Earth Sciences and Land Resources, Chang’an University, 126 Yanta Road, Xi’an 710054, China
| |
Collapse
|