Dadge SD, Yadav S, Rathaur S, Gayen JR. LC-ESI-MS/MS method validation for simultaneous quantification of FDA-approved anticancer agents futibatinib and binimetinib in rat plasma: Insights from preclinical pharmacokinetics. Biomed Chromatogr 2024; 38:e6005. [PMID: 39237854 DOI: 10.1002/bmc.6005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2024] [Revised: 08/14/2024] [Accepted: 08/18/2024] [Indexed: 09/07/2024]
Abstract
This study investigates the combination of FGFR inhibitor futibatinib (FTB) and MEK inhibitor binimetinib (BTB) for KRASmt NSCLC therapy. An analytical method was developed and validated for measuring FTB and BTB concentrations in rat plasma, adhering to USFDA guidelines. Using liquid-liquid extraction on 45-μL plasma samples, a 6.5-min run time was achieved. The linear calibration curve ranged from 2 to 100 ng/mL. Intra-day and inter-day accuracy ranged between 92.06% and 100.08%. Four blank injections post high-concentration samples resolved significant carryover. Extraction recoveries averaged 92.06% to 102.37% across concentrations. No significant endogenous interference was detected in blank plasma. The LLOQ for both drugs was 2.0 ng/mL. Selectivity, matrix effects, stability, and dilution integrity met the acceptance criteria. The method assessed FTB and BTB interaction potential in combination therapy at 5 mg/kg. The findings provide essential pharmacokinetics insights for future clinical trials.
Collapse
Affiliation(s)
- Shailesh D Dadge
- Pharmaceutics & Pharmacokinetics, CSIR-Central Drug Research Institute, Lucknow, 226031, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, 201002, India
| | - Shubhi Yadav
- Pharmaceutics & Pharmacokinetics, CSIR-Central Drug Research Institute, Lucknow, 226031, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, 201002, India
| | - Shivam Rathaur
- Pharmaceutics & Pharmacokinetics, CSIR-Central Drug Research Institute, Lucknow, 226031, India
| | - Jiaur R Gayen
- Pharmaceutics & Pharmacokinetics, CSIR-Central Drug Research Institute, Lucknow, 226031, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, 201002, India
- Pharmacology Division, CSIR-Central Drug Research Institute, Lucknow, 226031, India
| |
Collapse
|
2
|
Bellouard M, Donadieu J, Thiebot P, Giroux Leprieur E, Saiag P, Etting I, Dugues P, Abe E, Alvarez JC, Larabi IA. Validation of Liquid Chromatography Coupled with Tandem Mass Spectrometry for the Determination of 12 Tyrosine Kinase Inhibitors (TKIs) and Their Application to Therapeutic Drug Monitoring in Adult and Pediatric Populations. Pharmaceutics 2023; 16:5. [PMID: 38276485 PMCID: PMC10818921 DOI: 10.3390/pharmaceutics16010005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Revised: 12/12/2023] [Accepted: 12/15/2023] [Indexed: 01/27/2024] Open
Abstract
Tyrosine kinase inhibitors (TKIs) are used as targeted cancer therapies in adults and have an off-label pediatric application for the treatment of Langerhans cell histiocytosis. A multitarget LC-MS/MS method was developed and validated for the determination of alectinib, alectinib-M4, binimetinib, cobimetinib, crizotinib, dabrafenib, encorafenib, imatinib, lorlatinib, osimertinib, AZ5104, and trametinib. A total of 150 µL of internal standard methanolic solution was added to 50 µL of plasma sample to precipitate proteins. After centrifugation, 10 µL of the supernatant was injected into the chromatographic system. The chromatographic separation was conducted on a Kinetex C18 Polar column with a gradient of 2 mM ammonium formate in 0.1% formic acid and acetonitrile over 5 min. Limits of detection and quantification, linearity, accuracy, precision, selectivity, carryover, matrix effect, recovery, and stability were evaluated and satisfied EMA guidelines on bioanalytical methods. This method has been successfully applied to the therapeutic drug monitoring (TDM) of adults with melanoma and lung cancer, as well as children with histiocytosis, to improve the pharmacokinetic data for these drugs, with the aim of enhancing the therapeutic management and follow-up of patients. Blood concentrations of trametinib and binimetinib were different in the two groups, highlighting the age-related inter-individual variability of these molecules and the need for TDM.
Collapse
Affiliation(s)
- Marie Bellouard
- Toxicology Laboratory, Raymond Poincaré Hospital, AP-HP, 92380 Garches, France; (I.E.); (P.D.); (E.A.); (I.-A.L.); (J.-C.A.)
- Pediatric Hemato-Oncology Department, Trousseau Hospital, AP-HP, 75012 Paris, France;
| | - Jean Donadieu
- Pediatric Hemato-Oncology Department, Trousseau Hospital, AP-HP, 75012 Paris, France;
| | - Pauline Thiebot
- Toxicology Laboratory, Lariboisière Hospital, AP-HP, 75010 Paris, France;
| | | | - Philippe Saiag
- Dermatology Department, Ambroise Paré Hospital, AP-HP, 92100 Boulogne-Billancourt, France;
| | - Isabelle Etting
- Toxicology Laboratory, Raymond Poincaré Hospital, AP-HP, 92380 Garches, France; (I.E.); (P.D.); (E.A.); (I.-A.L.); (J.-C.A.)
| | - Pamela Dugues
- Toxicology Laboratory, Raymond Poincaré Hospital, AP-HP, 92380 Garches, France; (I.E.); (P.D.); (E.A.); (I.-A.L.); (J.-C.A.)
- Inserm U-1018, CESP, Team MOODS, Plateform MasSpecLab, Paris-Saclay/Versailles University, 78180 Montigny-le-Bretonneux, France
| | - Emuri Abe
- Toxicology Laboratory, Raymond Poincaré Hospital, AP-HP, 92380 Garches, France; (I.E.); (P.D.); (E.A.); (I.-A.L.); (J.-C.A.)
| | - Jean-Claude Alvarez
- Toxicology Laboratory, Raymond Poincaré Hospital, AP-HP, 92380 Garches, France; (I.E.); (P.D.); (E.A.); (I.-A.L.); (J.-C.A.)
- Inserm U-1018, CESP, Team MOODS, Plateform MasSpecLab, Paris-Saclay/Versailles University, 78180 Montigny-le-Bretonneux, France
| | - Islam-Amine Larabi
- Toxicology Laboratory, Raymond Poincaré Hospital, AP-HP, 92380 Garches, France; (I.E.); (P.D.); (E.A.); (I.-A.L.); (J.-C.A.)
- Inserm U-1018, CESP, Team MOODS, Plateform MasSpecLab, Paris-Saclay/Versailles University, 78180 Montigny-le-Bretonneux, France
| |
Collapse
|
3
|
A Liquid Chromatography Tandem Mass Spectrometry Method for the Simultaneous Estimation of the Dopamine Receptor Antagonist LE300 and Its N-methyl Metabolite in Plasma: Application to a Pharmacokinetic Study. Molecules 2023; 28:molecules28041553. [PMID: 36838539 PMCID: PMC9964957 DOI: 10.3390/molecules28041553] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 01/29/2023] [Accepted: 01/31/2023] [Indexed: 02/08/2023] Open
Abstract
LE300 is a novel dopamine receptor antagonist used to treat cocaine addiction. In the current study, a sensitive and fast liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been established and validated for the simultaneous analysis of LE300 and its N-methyl metabolite, MLE300, in rat plasma with an application in a pharmacokinetic study. The chromatographic elution of LE300, MLE300, and Ponatinib (IS, internal standard), was carried out on a 50 mm C18 analytical column (ID: 2.1 mm and particle size: 1.8 μm) maintained at 22 ± 2 °C. The run time was 5 min at a flow rate of 0.3 mL/min. The mobile phase consisted of 42% aqueous solvent (10 mM ammonium formate, pH: 4.2 with formic acid) and 58% organic solvent (acetonitrile). Plasma samples were pretreated using protein precipitation with acetonitrile. The electrospray ionization (ESI) source was used to generate an ion-utilizing positive mode. A multiple reaction monitoring mass analyzer mode was utilized for the quantification of analytes. The linearity of the calibration curves in rat plasma ranged from 1 to 200 ng/mL (r2 = 0.9997) and from 2 to 200 ng/mL (r2 = 0.9984) for LE300 and MLE300, respectively. The lower limits of detection (LLOD) were 0.3 ng/mL and 0.7 ng/mL in rat plasma for LE300 and MLE300, respectively. Accuracy (RE%) ranged from -1.71% to -0.07% and -4.18% to -1.48% (inter-day), and from -3.3% to -1.47% and -4.89% to -2.15% (intra-day) for LE300 and MLE300, respectively. The precision (RSD%) was less than 2.43% and 1.77% for the inter-day, and 2.77% and 1.73% for intra-day of LE300 and MLE300, respectively. These results are in agreement with FDA guidelines. The developed LC-MS/MS method was applied in a pharmacokinetic study in Wistar rats. Tmax and Cmax were 2 h and 151.12 ± 12.5 ng/mL for LE300, and 3 h and 170.4 ± 23.3 ng/mL for MLE300.
Collapse
|