1
|
Bhate M, Nagesh S. Assessment of the Effect of Thermoforming Process and Simulated Aging on the Mechanical Properties of Clear Aligner Material. Cureus 2024; 16:e64933. [PMID: 39156374 PMCID: PMC11330653 DOI: 10.7759/cureus.64933] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2024] [Accepted: 07/19/2024] [Indexed: 08/20/2024] Open
Abstract
Background Choosing the optimal aligner material on the market is crucial to ensure constant forces for tooth displacement. Processes like manufacturing and intraoral usage can result in the degradation of certain properties, which can affect the overall efficacy of treatment. Objective The objective of the study is to compare the surface roughness and flexural modulus of two aligner materials following the processes of thermoforming and aging. Materials and methods Two groups of 12 samples each were tested: Group 1 consisted of polyethylene terephthalate glycol (PET-G) and Group 2 of zendura-polyurethane (PU). The groups were tested at three time points: T0 - pre-thermoformed; T1 - after thermoforming; T2 - after thermoforming and aging. The surface roughness and the flexural modulus were evaluated. One-way ANOVA followed by a Bonferroni post hoc test was conducted to compare the changes within each group across the three times. An independent t-test was done to compare the values between the two groups at each time point. The statistical tests were performed using SPSS software version 26 (IBM Corp., Armonk, NY, USA). P-values >0.05 were considered statistically significant. Results There was a significant change in the surface roughness post-aging in Group 2 (p=0.03) and flexural strength within Group 1 (p=0.031) and Group 2 (p=0.06) across the three time points. Comparing the changes within the three time points in Group 1, significant changes were observed between T0-T1 (p=0.045) and T0-T2 (p=0.07). In Group 2, significant changes were observed between T0-T2 (p=0.012). Comparing the flexural strength between the two groups, significant differences were observed at T0 (p=0.012) and T1 (p=0.001). Conclusion The aging process affected the surface roughness in Zendura (PU). The thermoforming and aging process resulted in reduced flexural strength in both Zendura (PU) and Duran groups (PET-G).
Collapse
Affiliation(s)
- Manjiri Bhate
- Orthodontics and Dentofacial Orthopedics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, IND
| | - Shweta Nagesh
- Orthodontics and Dentofacial Orthopedics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, IND
| |
Collapse
|
2
|
Fouda AM, Bourauel C, Samran A, Kassem AS, Alhotan A. Effect of glazing and thermocycling on the fracture toughness and hardness of a New fully crystallized aluminosilicate CAD/CAM ceramic material. BMC Oral Health 2024; 24:620. [PMID: 38807109 PMCID: PMC11131322 DOI: 10.1186/s12903-024-04398-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2024] [Accepted: 05/22/2024] [Indexed: 05/30/2024] Open
Abstract
BACKGROUND The mechanical properties of fully crystallized lithium aluminosilicate ceramics may be influenced by intraoral temperature variations and postmilling surface treatment. The purpose of this study is to explore the interplay among glazing, thermocycling, and the mechanical characteristics (namely, fracture toughness and hardness) of fully crystallized lithium aluminosilicate ceramics. METHODS Bending bars (n = 40) cut from LisiCAD blocks (GC, Japan) were randomly assigned to glazed or unglazed groups (n = 20) and subjected to the single edge v-notch beam method to create notches. A glazing firing cycle was applied to the glazed group, while the unglazed group was not subjected to glazing. Half of the specimens (n = 10) from both groups underwent thermocycling before fracture toughness testing. The fracture toughness (KIC) was evaluated at 23 ± 1 °C using a universal testing machine configured for three-point bending, and the crack length was measured via light microscopy. Seven specimens per group were selected for the hardness test. Hardness was assessed using a Vickers microhardness tester with a 1 kg load for 20 s, and each specimen underwent five indentations following ISO 14705:2016. The Shapiro-Wilk and Kolmogorov-Smirnov tests were used to evaluate the normality of the data and a two-way ANOVA was utilized for statistical analysis. The significance level was set at (α = 0.05). RESULTS Regardless of the thermocycling conditions, the glazed specimens exhibited significantly greater fracture toughness than did their unglazed counterparts (P < 0.001). Thermocycling had no significant impact on the fracture toughness of either the glazed or unglazed specimens. Furthermore, statistical analysis revealed no significant effects on hardness with thermocycling in either group, and glazing alone did not substantially affect hardness. CONCLUSIONS The impact of glazing on the fracture toughness of LiSiCAD restorations is noteworthy, but it has no significant influence on their hardness. Furthermore, within the parameters of this study, thermocycling was found to exert negligible effects on both fracture toughness and hardness.
Collapse
Affiliation(s)
- Ahmed Mahmoud Fouda
- Department of Oral Technology, Medical Faculty, University Hospital Bonn, Welschnonnenstr. 17, 53111, Bonn, North Rhine-Westphalia, Germany.
- Department of Fixed Prosthodontics, Suez Canal University, Ismailia, Egypt.
| | - Christoph Bourauel
- Department of Oral Technology, Medical Faculty, University Hospital Bonn, Welschnonnenstr. 17, 53111, Bonn, North Rhine-Westphalia, Germany
| | - Abdulaziz Samran
- Department of Restorative and Prosthetic Dental Sciences, College of Dentistry, Dar Al-Uloom University, Riyadh, Saudi Arabia
- Department of Prosthodontics, School of Dentistry, Ibb University, Ibb, Yemen
| | - Amr Shebl Kassem
- Department of Fixed Prosthodontics, Suez Canal University, Ismailia, Egypt
| | - Abdulaziz Alhotan
- Department of Dental Health, College of Applied Medical Sciences, King Saud University, 7 Riyadh 12372, P.O. Box 10219, Riyadh, Saudi Arabia
| |
Collapse
|
3
|
Ikemoto S, Nagamatsu Y, Masaki C, Hosokawa R, Ikeda H. Development of zirconia-based polymer-infiltrated ceramic network for dental restorative material. J Mech Behav Biomed Mater 2024; 150:106320. [PMID: 38134584 DOI: 10.1016/j.jmbbm.2023.106320] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Revised: 12/09/2023] [Accepted: 12/11/2023] [Indexed: 12/24/2023]
Abstract
Polymer-infiltrated ceramic network (PICN) materials have gained considerable attention as tooth restorative materials owing to their mechanical compatibility with human teeth. However, the mechanical strength of contemporary PICN materials is lower than those of conventional resin composites and ceramics. This study aims to develop novel high-strength PICN for use as a dental restorative material. Zirconia-based PICN (EXP) was fabricated using 3 mol% yttria tetragonal polycrystalline zirconia powder and resin monomers via slip casting, followed by sintering and polymer infiltration. Comprehensive analyses of the microstructure, mechanical properties, and physicochemical properties of EXP were performed using scanning electron microscopy with energy-dispersive X-ray spectroscopy, Fourier transform infrared spectroscopy, inorganic content measurements, three-point bending test, Vickers hardness test, two-body wear test, shear bond strength (SBS) test, surface free energy analysis, and water sorption/solubility test. Commercially available computer-aided design/computer-aided manufacturing (CAD/CAM) materials, including resin composite (CERASMART), silicate-based PICN (ENAMIC), and zirconia ceramic (e.max ZirCAD), were used for comparison. The analyses highlight the dual network structure of EXP, which comprised a zirconia skeleton and an infiltrated resin phase. EXP exhibits a flexural strength of 346.0 ± 46.0 MPa, flexural modulus of 44.0 ± 3.7 GPa, and Vickers hardness of 440.1 ± 51.2 VHN. The mechanical properties of EXP are significantly higher than those of CERASMART and ENAMIC but lower than those of ZirCAD. Notably, the EXP hardness closely mimics that of the human enamel. The wear volume, SBS, and water sorption/solubility of EXP are comparable to those of CERASMART and ENAMIC. Therefore, EXP has potential applications as a tooth restorative material.
Collapse
Affiliation(s)
- Soshi Ikemoto
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Kitakyushu, 803-8580, Japan; Division of Oral Reconstruction and Rehabilitation, Department of Oral Functions, Kyushu Dental University, Kitakyushu, 803-8580, Japan
| | - Yuki Nagamatsu
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Kitakyushu, 803-8580, Japan
| | - Chihiro Masaki
- Division of Oral Reconstruction and Rehabilitation, Department of Oral Functions, Kyushu Dental University, Kitakyushu, 803-8580, Japan
| | - Ryuji Hosokawa
- Division of Oral Reconstruction and Rehabilitation, Department of Oral Functions, Kyushu Dental University, Kitakyushu, 803-8580, Japan
| | - Hiroshi Ikeda
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Kitakyushu, 803-8580, Japan.
| |
Collapse
|
4
|
Hajjaj MS, Alamoudi RAA, Babeer WA, Rizg WY, Basalah AA, Alzahrani SJ, Yeslam HE. Flexural strength, flexural modulus and microhardness of milled vs. fused deposition modeling printed Zirconia; effect of conventional vs. speed sintering. BMC Oral Health 2024; 24:38. [PMID: 38185744 PMCID: PMC10771678 DOI: 10.1186/s12903-023-03829-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Accepted: 12/26/2023] [Indexed: 01/09/2024] Open
Abstract
BACKGROUND Various methods can be used for creating zirconia dental restorations, including 3-dimensional (3D) printing and computer-aided design/ computer-aided manufacturing (CAD/CAM) milling. The fused deposition modeling (FDM) printing method for zirconia presents numerous advantages, albeit research on the mechanical properties of these materials and resultant restorations remains scarce. Such developments are undeniably intriguing and warrant further investigation. The objective of the present study was to evaluate the impact of the sintering firing cycle (Conventional vs. Speed sintering) on the flexural strength, flexural modulus, and Vickers Microhardness of milled vs. FDM printed zirconia. METHODS A total of 60 bars (2 × 5 × 27 mm) were fabricated for flexural strength testing, along with 40 discs (12 × 1.5 mm) for Vickers microhardness testing. Half of the specimens underwent conventional sintering, while the other half underwent a speed sintering cycle. The flexural strength and modulus were determined by a three-point bending test in a universal testing machine. The microhardness of the specimens was evaluated using a Vickers microhardness tester. Statistical analysis was performed using a two-way ANOVA test with a post-hoc Tukey test (p < 0.05). RESULTS CAD/CAM milled zirconia had significantly higher flexural strength and modulus than FDM-printed zirconia. The sintering process did not significantly affect the flexural strength or modulus of milled or FDM-printed zirconia. The milled speed sintering group had significantly higher values in the Vickers microhardness test compared to the other groups. CONCLUSIONS The mechanical properties of FDM-printed zirconia specimens were not found to be comparable to those of milled zirconia. Speed sintering cycle may produce milled zirconia restorations with similar flexural strength and modulus to conventional sintering, and even higher Vickers Microhardness values.
Collapse
Affiliation(s)
- Maher S Hajjaj
- Department of Restorative Dentistry, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia.
- Advanced Technology Dental Research Laboratory, King Abdulaziz University, P.O. Box 80209, Jeddah, 21589, Saudi Arabia.
| | - Rana A A Alamoudi
- Prosthodontic Master Student, Department of Oral and Maxillofacial Rehabilitation, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Walaa A Babeer
- Department of Oral and Maxillofacial Rehabilitation, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Waleed Y Rizg
- Department of Pharmaceutics, Faculty of Pharmacy, King Abdulaziz University, Jeddah, 21589, Saudi Arabia
- Center of Innovation in Personalized Medicine (CIPM), 3D Bioprinting Unit, King Abdulaziz University, Jeddah, 21589, Saudi Arabia
| | - Ahmad A Basalah
- Mechanical Engineering Department, College of Engineering and Architecture, Umm Al Qura University, Makkah, Saudi Arabia
| | - Saeed J Alzahrani
- Department of Restorative Dentistry, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Hanin E Yeslam
- Department of Restorative Dentistry, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
| |
Collapse
|