• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4605772)   Today's Articles (0)   Subscriber (49373)
For: Warman JM, De Haas MP, Luthjens LH, Denkova AG, Yao T. A Radio-Fluorogenic Polymer-Gel Makes Fixed Fluorescent Images of Complex Radiation Fields. Polymers (Basel) 2018;10:E685. [PMID: 30966719 PMCID: PMC6404135 DOI: 10.3390/polym10060685] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2018] [Revised: 06/13/2018] [Accepted: 06/16/2018] [Indexed: 11/23/2022]  Open
Number Cited by Other Article(s)
1
Karger CP, Elter A, Dorsch S, Mann P, Pappas E, Oldham M. Validation of complex radiotherapy techniques using polymer gel dosimetry. Phys Med Biol 2024;69:06TR01. [PMID: 38330494 DOI: 10.1088/1361-6560/ad278f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Accepted: 02/08/2024] [Indexed: 02/10/2024]
2
Improvement of light stability of DHR123 radio fluorogenic nano clay gel dosimeter by incorporating a new dispersant. J Photochem Photobiol A Chem 2021. [DOI: 10.1016/j.jphotochem.2021.113423] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
3
Yang T, Wang J, Tu J, Zhou X, Sun J, Chen J, Wen W, Wang Y. Rare-earth doped radioluminescent hydrogel as a potential phantom material for 3D gel dosimeter. E-POLYMERS 2021. [DOI: 10.1515/epoly-2021-0053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
4
Marrale M, d’Errico F. Hydrogels for Three-Dimensional Ionizing-Radiation Dosimetry. Gels 2021;7:74. [PMID: 34205640 PMCID: PMC8293215 DOI: 10.3390/gels7020074] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2021] [Revised: 06/15/2021] [Accepted: 06/16/2021] [Indexed: 11/28/2022]  Open
5
Watanabe Y, Maeyama T, Mochizuki A, Mizukami S, Hayashi SI, Terazaki T, Muraishi H, Takei H, Gomi T, Shimono T. Verification of dose distribution in high-dose-rate brachytherapy using a nanoclay-based radio-fluorogenic gel dosimeter. Phys Med Biol 2020;65:175008. [PMID: 32485693 DOI: 10.1088/1361-6560/ab98d2] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
6
Warman JM, de Haas MP, Luthjens LH, Yao T, Navarro-Campos J, Yuksel S, Aarts J, Thiele S, Houter J, In Het Zandt W. FluoroTome 1: An Apparatus for Tomographic Imaging of Radio-Fluorogenic (RFG) Gels. Polymers (Basel) 2019;11:E1729. [PMID: 31652759 PMCID: PMC6918256 DOI: 10.3390/polym11111729] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2019] [Revised: 10/22/2019] [Accepted: 10/22/2019] [Indexed: 11/16/2022]  Open
7
Luthjens LH, Yao T, Warman JM. A Polymer-Gel Eye-Phantom for 3D Fluorescent Imaging of Millimetre Radiation Beams. Polymers (Basel) 2018;10:E1195. [PMID: 30961120 PMCID: PMC6290594 DOI: 10.3390/polym10111195] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2018] [Revised: 10/18/2018] [Accepted: 10/23/2018] [Indexed: 11/23/2022]  Open
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA