1
|
Saini RS, Bavabeedu SS, Quadri SA, Gurumurthy V, Kanji MA, Okshah A, Binduhayyim RIH, Alarcón-Sánchez MA, Mosaddad SA, Heboyan A. Mapping the research landscape of nanoparticles and their use in denture base resins: a bibliometric analysis. DISCOVER NANO 2024; 19:95. [PMID: 38814562 PMCID: PMC11139848 DOI: 10.1186/s11671-024-04037-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2024] [Accepted: 05/22/2024] [Indexed: 05/31/2024]
Abstract
BACKGROUND Nanoparticles are increasingly used in dentistry for various applications, including enhancing the mechanical properties of denture base resins. This study aimed to comprehensively review and analyze the research landscape of nanoparticles and their effect on the flexural strength of denture base resins to identify key research areas and trends and to highlight the importance of collaboration between authors and institutions. METHODS A Bibliometric Analysis was conducted using the Keywords "Nanoparticle*" AND "Denture*" OR "CAD/CAM." The literature search from the WOS database was restricted to the publication years 2011 to 2022. RESULTS Key findings encompass an increase in research publications but a decline in citations. Saudi Arabia, China, and Iraq led this research, with specific institutions excelling. Notable journals with high impact factors were identified. Authorship patterns show variations in citation impact. Additionally, keyword analysis revealed that current research trends offer insights into influential authors and their networks. CONCLUSIONS The analysis of nanoparticles and denture base resins reveals a dynamic and evolving landscape that emphasizes the importance of collaboration, staying current with research trends, and conducting high-quality research in this ever-evolving domain.
Collapse
Affiliation(s)
- Ravinder S Saini
- Department of Dental Technology, COAMS, King Khalid University, Abha, Saudi Arabia
| | - Shashit Shetty Bavabeedu
- Department of Restorative Dental Sciences, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | | | | | - Masroor Ahmed Kanji
- Department of Dental Technology, COAMS, King Khalid University, Abha, Saudi Arabia
| | - Abdulmajeed Okshah
- Department of Dental Technology, COAMS, King Khalid University, Abha, Saudi Arabia
| | | | - Mario Alberto Alarcón-Sánchez
- Faculty of Chemical-Biological Sciences, Autonomous University of Guerrero, Chilpancingo de los Bravo, Guerrero, Mexico
| | - Seyed Ali Mosaddad
- Department of Research Analytics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, India.
- Student Research Committee, School of Dentistry, Shiraz University of Medical Sciences, Qasr-e-Dasht Street, Shiraz, Iran.
| | - Artak Heboyan
- Department of Research Analytics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, India.
- Department of Prosthodontics, Faculty of Stomatology, Yerevan State Medical University after Mkhitar Heratsi, Str. Koryun 2, 0025, Yerevan, Armenia.
| |
Collapse
|
2
|
Oyar P, Ulusoy M. Effect of milling procedures in CAD-CAM systems on the color changes of CAD-CAM polymethyl methacrylate resin material as interim material. BMC Oral Health 2024; 24:618. [PMID: 38807102 PMCID: PMC11131249 DOI: 10.1186/s12903-024-04350-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2024] [Accepted: 05/08/2024] [Indexed: 05/30/2024] Open
Abstract
PURPOSE This study aimed to investigate the effects of new and used burs on CAD-CAM PMMA resin color changes following thermocycling. MATERIALS AND METHODS Twenty disk-shaped specimens (10 × 2 mm) were made using a single brand of CAD-CAM polymethyl methacrylate resin (Polident) for the color test. Group N consisted of half of the specimens that were machined using the new tungsten carbide bur set, and Group U consisted of the specimens that were milled using the used bur set (500 machining time). A color test was performed on the specimens both before and after thermocycling. For the statistical analysis, the Kruskal-Wallis and Dunn Pairwise Comparison tests were employed. RESULTS The ∆E* value of specimens (2.057) milled with the used bur was higher than those of specimens milled with the new bur (0.340), but this value is within clinically acceptable limits. After thermocycling, specimens milled with the utilized burs had the greatest L* (93.850) and b* (5.000) values. After thermocycling, statistically significant differences were discovered between Group N and Group U as well as between specimens milled with the utilized bur before and after thermocycling. CONCLUSION Thermocycling process have an effect on the mean ∆E values of specimens milled with the used carbide bur, but these ∆E* values were not statistically significant. CLINICAL SIGNIFICANCE The color and clinical performance of CAD-CAM restorations may be affected by variations in CAD-CAM milling bur properties, particularly those related to their frequent use.
Collapse
Affiliation(s)
- Perihan Oyar
- Department of Dental Prostheses Technology, Health Services Vocational High School, Hacettepe University, D Block, 3. Floor, Sihhiye, 06100, Ankara, Turkey.
| | - Mutahhar Ulusoy
- Department of Prosthodontics, Faculty of Dentistry, Near East University, Mersin, 10, Turkey
| |
Collapse
|
3
|
Temizci T, Bozoğulları HN. Effect of thermocycling on the mechanical properties of permanent composite-based CAD-CAM restorative materials produced by additive and subtractive manufacturing techniques. BMC Oral Health 2024; 24:334. [PMID: 38486195 PMCID: PMC10938812 DOI: 10.1186/s12903-024-04016-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Accepted: 02/12/2024] [Indexed: 03/18/2024] Open
Abstract
BACKGROUND The aim of the study was to determine and compare the biaxial flexural strength (BFS) and Vickers hardness (VHN) of additive and subtractive manufactured permanent composite-based restorative materials, before and after thermal aging. METHODS A total of 200 specimens were prepared; 100 disc-shaped specimens (diameter 13 × 1.2 mm) for the BFS test and 100 square specimens (14 × 14 × 2 mm) for the VHN test. The specimens were made from various materials: two subtractive composite-based blocks (Cerasmart 270 [CS], Vita Enamic [VE]), two additive composite-based resins used for two different vat polymerization methods (digital light processing [DLP]; Saremco Print Crowntec [SC] and stereolithography [SLA]; Formlabs Permanent Crown Resin [FP]), and one feldspathic glass-matrix ceramic block (Vita Mark II [VM]) as the control group. Specimens of each material were divided into two subgroups: thermal cycled or non-thermal cycled (n = 10). BFS and VHN tests were performed on all groups. Data were analyzed with two-way ANOVA and post hoc Tukey test (α = 0.05). RESULTS The type of restorative material used for the specimen had a statistically significant influence on both BFS and VHN values. However, thermal cycling did not affect the BFS and VHN values. After thermal cycling, the results of the BFS test were ranked from best to worst as follows: CS, FP, SC, VE, then VM. For the VHN values, the order from best to worst was as follows: VM, VE, CS, FP, then SC. CONCLUSIONS 3D printed and milled composite groups showed higher BFS than feldspathic ceramics. When the VHN results were examined, it was seen that the 3D resin groups had the lowest VHN values. Furthermore, it was observed that the thermal cycle had no effect on BFS or VHN.
Collapse
Affiliation(s)
- Tuğba Temizci
- Department of Prosthodontics, Faculty of Dentistry, Karamanoğlu Mehmetbey University, Karaman, Turkey.
| | - Hatice Nalan Bozoğulları
- Department of Prosthodontics, Faculty of Dentistry, Karamanoğlu Mehmetbey University, Karaman, Turkey
| |
Collapse
|
4
|
Karaokutan I, Ayvaz I. Effect of various surface treatments on relining bond strength of CAD-CAM denture base materials. J Prosthodont 2024. [PMID: 38369895 DOI: 10.1111/jopr.13831] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Accepted: 02/01/2024] [Indexed: 02/20/2024] Open
Abstract
PURPOSE The aim of this study was to analyze the impact of various surface treatments and production methods on the shear bond strength (SBS) between reline material and denture base resins. MATERIALS AND METHODS One-hundred-twenty specimens were produced using conventional heat-polymerization, subtractive, and additive techniques. Each group consisted of 40 specimens. The specimens were divided into four subgroups, each with 10 samples, for surface treatments. These subgroups were: (1) Control-only monomer application, (2) 50 μm airborne-particle abrasion, (3) 110 μm airborne-particle abrasion, and (4) Roughening with tungsten carbide bur. Representative specimens from each subgroup were examined under SEM. Then, auto-polymerized resin was condensed in the center of the specimens. Specimens were subjected to thermal aging (5000 cycles at 5-55°C). The SBS test was conducted and failure loads were recorded. The data were evaluated by two-way ANOVA and Tukey pairwise multiple comparisons method (p < 0.05). RESULTS The additively produced group showed significantly lower SBS than conventional and subtractive groups (p < 0.001), with no significant differences between the subtractive and conventional groups. Specimens that underwent monomer application only showed the lowest SBS among surface treatments, while 50 μm airborne-particle abrasion showed the highest SBS. Based on the partial eta-squared analysis results, the surface treatment mainly impacted SBS. CONCLUSIONS Among the surface treatment methods, treating denture bases with 50 μm airborne-particle abrasion is more effective for maintaining adhesion, especially in the additive technique.
Collapse
Affiliation(s)
- Isil Karaokutan
- Department of Prosthodontics, Faculty of Dentistry, Pamukkale University, Denizli, Turkey
| | - Ilayda Ayvaz
- Department of Prosthodontics, Faculty of Dentistry, Pamukkale University, Denizli, Turkey
| |
Collapse
|
5
|
Sadek HMA, El-Banna A. Biaxial flexural strength of different provisional restorative materials under chemo-mechanical aging: An in vitro study. J Prosthodont 2024; 33:149-156. [PMID: 36738226 DOI: 10.1111/jopr.13662] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2022] [Revised: 01/22/2023] [Accepted: 01/24/2023] [Indexed: 02/05/2023] Open
Abstract
PURPOSE Durability is a critical factor for the success of long-term provisional restorations. This study evaluated the effect of different storage media and cyclic loading on the biaxial flexural strength of different types of provisional materials. MATERIALS AND METHODS Discs (N = 360, 10 × 2 mm) were prepared from different provisional materials; conventional (Protemp 4, Tuff-Temp, Tempron), CAD-CAM milled (VITA CAD-Temp, breCAM.multiCOM), and 3D-printed (Nextdent C&B MFH) (n = 60). Each material group was subdivided into four subgroups according to the storage media (n = 15): nonaged, artificial saliva, mouthwash, and coffee. The specimens in storage media were placed in an incubator at 37°C for 4 weeks followed by 60,000 simulated chewing cycles. Biaxial flexural strength test was done. Data were analyzed using two-way ANOVA. Weibull distribution parameters were estimated. RESULTS Both the material and aging protocol showed a significant effect on the biaxial flexural strength. Both Protemp 4 and Nextdent C&B MFH showed a significantly higher biaxial flexural strength before and after aging compared to all other materials. Protemp 4 and Tuff Temp showed a significant decrease in strength with aging. CAD-CAM materials showed higher Weibull moduli. CONCLUSIONS The 3D-printed polymethylmethacrylate provisional material presents with both greater biaxial flexural strength and increased durability against chemical and mechanical aging compared to conventional and CAD-CAM milled provisional materials tested.
Collapse
Affiliation(s)
- Hoda M Abdel Sadek
- Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
| | - Ahmed El-Banna
- Department of Dental Biomaterials, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
| |
Collapse
|
6
|
Sahrir CD, Ruslin M, Lee SY, Lin WC. Effect of various post-curing light intensities, times, and energy levels on the color of 3D-printed resin crowns. J Dent Sci 2024; 19:357-363. [PMID: 38303871 PMCID: PMC10829711 DOI: 10.1016/j.jds.2023.07.008] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Revised: 07/06/2023] [Indexed: 02/03/2024] Open
Abstract
Background/purpose Current 3D-printing technology has been widely used for creating dental resin restorations. This study aimed to evaluate the effect of light intensity, time, and energy post-curing on the surface color of 3D-printed resin crowns. However, the influences of post-curing parameters on the restoration after printing still need to be explored. Therefore, this project investigates the effect of post-cure conditions on resin color. Materials and methods Specimens from single-crown (SC) and pontic (PO) specimens underwent post-curing at various light intensities (105, 210, 420, 630, and 860 mW/cm2) for 5, 10, and 15 min. Specimens were observed at three predetermined points and measured using a commercial spectrophotometer that utilizes the CIE Lab∗ color space. Subsequently, samples were analyzed for color differences (ΔE). Results ΔE color differences in evaluated samples were influenced by the light intensity, time, and energy post-curing. SC samples showed a significant color difference (P < 0.05), with the lowest value at 5 min of 16 (860 mW/cm2), while 10 and 15 min had a difference of 4 (210 mW/cm2). PO samples exhibited a significant decrease in the color difference (P < 0.05) at 5 and 10 min of 16 (860 mW/cm2), and at 15 min of 12 (630 mW/cm2). Conclusion The results of this study indicate that exposing a resin crown to a high light intensity results in color stability and allows shorter post-curing times.
Collapse
Affiliation(s)
- Citra Dewi Sahrir
- School of Dental Technology, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan
| | - Muhammad Ruslin
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Hasanuddin University, Makassar, Indonesia
| | - Sheng-Yang Lee
- Department of Dentistry, Wan-Fang Hospital, Taipei Medical University, Taipei, Taiwan
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan
- Center for Tooth Bank and Dental Stem Cell Technology, Taipei Medical University, Taipei, Taiwan
| | - Wei-Chun Lin
- School of Dental Technology, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan
- Department of Dentistry, Wan-Fang Hospital, Taipei Medical University, Taipei, Taiwan
- Center for Tooth Bank and Dental Stem Cell Technology, Taipei Medical University, Taipei, Taiwan
| |
Collapse
|
7
|
Fouda SM, Gad MM, Ellakany P, El Zayat M, Farooqi FA, Akhtar S, Salah El-Din M. Influence of denture brushing on the surface properties and color stability of CAD-CAM, thermoformed, and conventionally fabricated denture base resins. J Prosthodont 2023. [PMID: 37953735 DOI: 10.1111/jopr.13801] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Revised: 11/05/2023] [Accepted: 11/09/2023] [Indexed: 11/14/2023] Open
Abstract
PURPOSE To assess the influence of denture brushing on the surface roughness, hardness, and color stability of conventional, thermoformed, and CAD-CAM denture base materials. MATERIALS AND METHODS Seven different denture base materials were included in this study; conventional heat-polymerized acrylic resin (PMMA) served as control, polyamide, acetal, two categories of milled acrylic discs (AvaDent and IvoCad), and two categories of 3D-printed resins (NextDent and FormLabs). The specimens were constructed according to manufacturers' instructions and then subjected to simulated brushing (20,000 cycles). According to the brushing method, the specimens were split into three groups, no brushing, brushing with water, and brushing with toothpaste. Surface roughness, hardness, and color change were evaluated before and after brushing. Collected data were analyzed using ANOVA, and post-hoc Tukey's tests (α = 0.05). RESULTS A significant difference was noted between the surface roughness of the tested materials before and after denture brushing (p < 0.05), and milled resin showed the least Ra values. Denture brushing with water significantly increased the Ra of PMMA (p = 0.004) and IvoCad (p = 0.032), while brushing using toothpaste did not show a significant increase. The brushing protocols did not alter the hardness of tested materials except that of PMMA (p = 0.001). The color stability of the tested materials showed comparable results with both brushing protocols. CONCLUSION The tested properties showed variations between the types of denture base resins. Hardness and color stability of CAD-CAM and thermoformed denture base resins were not altered by denture brushing and showed comparable results with both brushing methods. Surface roughness was the only property that showed alteration after denture brushing.
Collapse
Affiliation(s)
- Shaimaa M Fouda
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Mohammed M Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Passent Ellakany
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Mai El Zayat
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Faraz A Farooqi
- Department of Dental Education, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Sultan Akhtar
- Department of Biophysics, Institute for Research and Medical Consultations (IRMC), Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Mai Salah El-Din
- Prosthodontics Department, Alexandria University Main Hospitals, Alexandria, Egypt
| |
Collapse
|
8
|
Othman A, Sandmair M, Alevizakos V, von See C. The fracture resistance of 3D-printed versus milled provisional crowns: An in vitro study. PLoS One 2023; 18:e0285760. [PMID: 37656728 PMCID: PMC10473469 DOI: 10.1371/journal.pone.0285760] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Accepted: 04/29/2023] [Indexed: 09/03/2023] Open
Abstract
BACKGROUND CAD/CAM has considerably transformed the clinical practice of dentistry. In particular, advanced dental materials produced via digital technologies offer unquestionable benefits, such as ideal mechanical stability, outstanding aesthetics and reliable high precision. Additive manufacturing (AM) technology has promoted new innovations, especially in the field of biomedicine. AIMS The aim of this study is to analyze the fracture resistance of implant-supported 3D-printed temporary crowns relative to milled crowns by compression testing. METHODS The study sample included 32 specimens of temporary crowns, which were divided into 16 specimens per group. Each group consisted of eight maxillary central incisor crowns (tooth 11) and eight maxillary molar crowns (tooth 16). The first group (16 specimens) was 3D printed by a mask printer (Varseo, BEGO, Bremen, Germany) with a temporary material (VarseoSmile Temp A3, BEGO, Bremen, Germany). The second group was milled with a millable temporary material (VitaCAD Temp mono-color, Vita, Bad Säckingen, Germany). The two groups were compression tested until failure to estimate their fracture resistance. The loading forces and travel distance until failure were measured. The statistical analysis was performed using SPSS Version 24.0. We performed multiple t tests and considered a significance level of p <0.05. RESULTS The mean fracture force of the printed molars was 1189.50 N (±250.85) with a deformation of 1.75 mm (±0.25). The milled molars reached a mean fracture force of 1817.50 N (±258.22) with a deformation of 1.750 mm (±0.20). The printed incisors fractured at 321.63 N (±145.90) with a deformation of 1.94 mm (±0.40), while the milled incisors fractured at 443.38 N (±113.63) with a deformation of 2.26 mm (±0.40). The milled molar group revealed significantly higher mechanical fracture strength than the 3D-printed molar group (P<0.001). However, no significant differences between the 3D-printed incisors and the milled incisors were found (p = 0.084). There was no significant difference in the travel distance until fracture for both the molar group (p = 1.000) and the incisor group (p = 0.129). CONCLUSION Within the limits of this in vitro investigation, printed and milled temporary crowns withstood masticatory forces and were safe for clinical use.
Collapse
Affiliation(s)
- Ahmed Othman
- Research Center for Digital Technologies in Dentistry and CAD/CAM, Department of Dentistry, Faculty of Medicine and Dentistry, Danube Private University, Krems, Austria
| | - Maximillian Sandmair
- Research Center for Digital Technologies in Dentistry and CAD/CAM, Department of Dentistry, Faculty of Medicine and Dentistry, Danube Private University, Krems, Austria
| | - Vasilios Alevizakos
- Research Center for Digital Technologies in Dentistry and CAD/CAM, Department of Dentistry, Faculty of Medicine and Dentistry, Danube Private University, Krems, Austria
| | - Constantin von See
- Research Center for Digital Technologies in Dentistry and CAD/CAM, Department of Dentistry, Faculty of Medicine and Dentistry, Danube Private University, Krems, Austria
| |
Collapse
|
9
|
Wada J, Wada K, Garoushi S, Shinya A, Wakabayashi N, Iwamoto T, Vallittu PK, Lassila L. Effect of 3D printing system and post-curing atmosphere on micro- and nano-wear of additive-manufactured occlusal splint materials. J Mech Behav Biomed Mater 2023; 142:105799. [PMID: 37028121 DOI: 10.1016/j.jmbbm.2023.105799] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Revised: 03/10/2023] [Accepted: 03/23/2023] [Indexed: 04/07/2023]
Abstract
Although additive manufacturing has been widely applied for occlusal splint (OS) fabrication, it is still unclear whether 3D printing system and post-curing atmosphere would play a role in the wear resistance of additive-manufactured OS. Therefore, the aim of this study was to evaluate the effect of 3D printing system (liquid crystal display (LCD) and digital light processing (DLP)) and post-curing atmosphere (air and nitrogen gas (N2)) on the wear resistance of hard and soft OS materials for additive-manufactured OSs (KeySplint® Hard and Soft). The evaluated properties were microwear (by two-body wear test) and nano-wear resistances (by nanoindentation wear test) as well as flexural strength and flexural modulus (by three-point bending test), surface microhardness (by Vickers hardness test), and nanoscale elastic modulus (reduced elastic modulus) and nano surface hardness (by nanoindentation test). For the hard material, the surface microhardness, microwear resistance, reduced elastic modulus, nano surface hardness, and nano-wear resistance were significantly affected by the printing system (p < 0.05), while all the evaluated properties except flexural modulus were significantly affected by the post-curing atmosphere (p < 0.05). Meanwhile, both the printing system and post-curing atmosphere significantly affected all the evaluated properties (p < 0.05). The specimens additive-manufactured by DLP printer tended to show higher wear resistance in the hard material groups and lower wear resistance in the soft material groups when compared to those by LCD printer. The post-curing at N2 atmosphere significantly enhanced the microwear resistance of hard material groups additive-manufactured by the DLP printer (p < 0.05) and soft material groups additive-manufactured by the LCD printer (p < 0.01), while it significantly enhanced the nano-wear resistance of both hard and soft material groups regardless of the printing system (p < 0.01). It can be concluded that 3D printing system and post-curing atmosphere affect the micro- and nano-wear resistance of tested additively manufactured OS materials. In addition, it can be also concluded that the optical printing system providing higher wear resistance depends on the material type, and using nitrogen gas as a protection gas during post-curing enhances the wear resistance of tested materials.
Collapse
|
10
|
Celik HK, Koc S, Kustarci A, Caglayan N, Rennie AE. The state of additive manufacturing in dental research - A systematic scoping review of 2012-2022. Heliyon 2023; 9:e17462. [PMID: 37484349 PMCID: PMC10361388 DOI: 10.1016/j.heliyon.2023.e17462] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Revised: 06/08/2023] [Accepted: 06/19/2023] [Indexed: 07/25/2023] Open
Abstract
Background/purpose Additive manufacturing (AM), also known as 3D printing, has the potential to transform the industry. While there have been advancements in using AM for dental restorations, there is still a need for further research to develop functional biomedical and dental materials. It's crucial to understand the current status of AM technology and research trends to advance dental research in this field. The aim of this study is to reveal the current status of international scientific publications in the field of dental research related to AM technologies. Materials and methods In this study, a systematic scoping review was conducted using appropriate keywords within the scope of international scientific publishing databases (PubMed and Web of Science). The review included related clinical and laboratory research, including both human and animal studies, case reports, review articles, and questionnaire studies. A total of 187 research studies were evaluated for quantitative synthesis in this review. Results The findings highlighted a rising trend in research numbers over the years (From 2012 to 2022). The most publications were produced in 2020 and 2021, with annual percentage increases of 25.7% and 26.2%, respectively. The majority of AM-related publications in dentistry research originate from Korea. The pioneer dental sub-fields with the ost publications in its category are prosthodontics and implantology, respectively. Conclusion The final review result clearly stated an expectation for the future that the research in dentistry would concentrate on AM technologies in order to increase the new product and process development in dental materials, tools, implants and new generation modelling strategy related to AM. The results of this work can be used as indicators of trends related to AM research in dentistry and/or as prospects for future publication expectations in this field.
Collapse
Affiliation(s)
- H. Kursat Celik
- Dept. of Agr. Machinery and Technology Engineering, Akdeniz University, Antalya, 07070, Turkey
| | - Simay Koc
- Dept. of Endodontics, Fac. of Dentistry, Akdeniz University, Antalya, Turkey
| | - Alper Kustarci
- Dept. of Endodontics, Fac. of Dentistry, Akdeniz University, Antalya, Turkey
| | - Nuri Caglayan
- Dept. of Mechatronics, Fac. of Engineering, Akdeniz University, Antalya, Turkey
| | | |
Collapse
|
11
|
Alzahrani SJ, Hajjaj MS, Azhari AA, Ahmed WM, Yeslam HE, Carvalho RM. Mechanical Properties of Three-Dimensional Printed Provisional Resin Materials for Crown and Fixed Dental Prosthesis: A Systematic Review. Bioengineering (Basel) 2023; 10:663. [PMID: 37370594 DOI: 10.3390/bioengineering10060663] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Revised: 05/14/2023] [Accepted: 05/29/2023] [Indexed: 06/29/2023] Open
Abstract
The emergence of digital dentistry has led to the introduction of various three-dimensional (3D) printing materials in the market, specifically for provisional fixed restoration. This study aimed to undertake a systematic review of the published literature on the Mechanical Properties of 3D- Printed Provisional Resin Materials for crown and fixed dental prosthesis (FDP). The electronic database on PubMed/Medline was searched for relevant studies. The search retrieved articles that were published from January 2011 to March 2023. The established focus question was: "Do provisional 3D-printed materials have better mechanical properties than conventional or milled provisional materials?". The systematically extracted data included the researcher's name(s), publication year, evaluation method, number of samples, types of materials, and study outcome. A total of 19 studies were included in this systematic review. These studies examined different aspects of the mechanical properties of 3D-printed provisional materials. Flexural Strength and Microhardness were the frequently used mechanical testing. Furthermore, 3D-printed provisional restorations showed higher hardness, smoother surfaces, less wear volume loss, and higher wear resistance compared to either milled or conventional, or both. 3D-printed provisional resin materials appear to be a promising option for fabricating provisional crowns and FDPs.
Collapse
Affiliation(s)
- Saeed J Alzahrani
- Department of Restorative Dentistry, Faculty of Dentistry, King Abdulaziz University, Jeddah 21589, Saudi Arabia
| | - Maher S Hajjaj
- Department of Restorative Dentistry, Faculty of Dentistry, King Abdulaziz University, Jeddah 21589, Saudi Arabia
| | - Amr Ahmed Azhari
- Department of Restorative Dentistry, Faculty of Dentistry, King Abdulaziz University, Jeddah 21589, Saudi Arabia
| | - Walaa Magdy Ahmed
- Department of Restorative Dentistry, Faculty of Dentistry, King Abdulaziz University, Jeddah 21589, Saudi Arabia
| | - Hanin E Yeslam
- Department of Restorative Dentistry, Faculty of Dentistry, King Abdulaziz University, Jeddah 21589, Saudi Arabia
| | - Ricardo Marins Carvalho
- Department of Oral Biological and Medical Science, Faculty of Dentistry, The University of British Columbia, Vancouver, BC V63 1Z3, Canada
| |
Collapse
|
12
|
Ellakany P, Aly NM, Alghamdi MM, Alameer ST, Alshehri T, Akhtar S, Madi M. Effect of Different Scaling Methods on the Surface Topography of Different CAD/CAM Ceramic Compositions. MATERIALS (BASEL, SWITZERLAND) 2023; 16:2974. [PMID: 37109810 PMCID: PMC10143924 DOI: 10.3390/ma16082974] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 03/25/2023] [Accepted: 04/03/2023] [Indexed: 06/19/2023]
Abstract
This study evaluated the effect of ultrasonic and manual scaling using different scaler materials on the surface topography of computer-aided designing and computer-aided manufacturing (CAD/CAM) ceramic compositions. After scaling with manual and ultrasonic scalers, the surface properties of four classes of CAD/CAM ceramic discs: lithium disilicate (IPE), leucite-reinforced (IPS), advanced lithium disilicate (CT), and zirconia-reinforced lithium silicate (CD) of 1.5 mm thickness were evaluated. Surface roughness was measured before and after treatment, and scanning electron microscopy was used to evaluate the surface topography following the performed scaling procedures. Two-way ANOVA was conducted to assess the association of the ceramic material and scaling method with the surface roughness. There was a significant difference in the surface roughness between the ceramic materials subjected to different scaling methods (p < 0.001). Post-hoc analyses revealed significant differences between all groups except for IPE and IPS where no significant differences were detected between them. CD showed the highest surface roughness values, while CT showed the lowest surface roughness values for the control specimens and after exposure to different scaling methods. Moreover, the specimens subjected to ultrasonic scaling displayed the highest roughness values, while the least surface roughness was noted with the plastic scaling method.
Collapse
Affiliation(s)
- Passent Ellakany
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| | - Nourhan M. Aly
- Department of Pediatric Dentistry and Dental Public Health, Faculty of Dentistry, Alexandria University, Alexandria 21527, Egypt
| | - Maram M. Alghamdi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| | - Shahad T. Alameer
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| | - Turki Alshehri
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| | - Sultan Akhtar
- Department of Biophysics, Institute for Research and Medical Consultations (IRMC), Imam Abdulrahman Bin Faisal University, Dammam 31441, Saudi Arabia
| | - Marwa Madi
- Department of Preventive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| |
Collapse
|
13
|
Mert D, Kamnoedboon P, Al-Haj Husain N, Özcan M, Srinivasan M. CAD-CAM complete denture resins: Effect of relining on the shear bond strength. J Dent 2023; 131:104438. [PMID: 36717051 DOI: 10.1016/j.jdent.2023.104438] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Revised: 12/20/2022] [Accepted: 01/26/2023] [Indexed: 01/30/2023] Open
Abstract
OBJECTIVES The aim of this study was to compare the shear bond strength of relined CAD-CAM complete removable dental prosthesis (CRDP) resins with conventional heat-polymerized polymethylmethacrylate (PMMA) resin. METHODS A total of 96 resin specimens in identical dimensions of 10 mm × 10 mm × 11 mm were fabricated for four study groups [#1- Conventional heat-polymerized group: n=24 (ProBase); #2- Milled#1: n=24 (Ivobase); #3- Milled#2: n=24 (Ivotion); #4- 3D-printed: n=24, (NextDent Denture 3D+)]. Twelve specimens in each group were sectioned in the middle to produce a 3 mm defect and then were relined using a conventional denture relining material. All specimens underwent thermocycling (5-55°C) for 10,000 cycles. The shear bond tests were carried out in a universal testing machine. One-way ANOVA and Tukey's test were used for statistical analysis (p<0.05). The two-parameter Weibull distribution values were calculated. RESULTS Relined 3D-printed specimens had a significantly lower shear bond strength when compared with conventional (p=0.0003) and milled groups (Milled#1: p=0.0004; Milled#2: p<0.0001). There were no differences in the shear bond strengths between the milled and conventional groups. Weibull distribution presented the highest shape value for the non-relined Milled#1 (22.83) group and the lowest values for the 3D-printed relined group (4.001). CONCLUSION The findings of this study conclude that the shear bond strength of the conventionally-relined 3D-printed resins used for fabricating CRDPs was inferior to the shear bond strength of conventionally-relined resins employed for manufacturing CRDPs using CAD-CAM milling and conventional heat-polymerization techniques. CLINICAL SIGNIFICANCE When considering 3D-printing for the fabrication of CRDPs, it is recommended to employ it in clinical situations where a frequent need for denture relining is not expected.
Collapse
Affiliation(s)
- Dilvin Mert
- Clinic of General, Special Care and Geriatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland.
| | - Porawit Kamnoedboon
- Clinic of General, Special Care and Geriatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Nadin Al-Haj Husain
- Division of Dental Biomaterials, Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Mutlu Özcan
- Division of Dental Biomaterials, Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Murali Srinivasan
- Clinic of General, Special Care and Geriatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| |
Collapse
|
14
|
Ellakany P, Fouda SM, AlGhamdi MA, Aly NM. Comparison of the color stability and surface roughness of 3-unit provisional fixed partial dentures fabricated by milling, conventional and different 3D printing fabrication techniques. J Dent 2023; 131:104458. [PMID: 36806621 DOI: 10.1016/j.jdent.2023.104458] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Revised: 01/26/2023] [Accepted: 02/15/2023] [Indexed: 02/19/2023] Open
Abstract
OBJECTIVES To compare the color stability and surface roughness of 3-unit provisional fixed partial dentures (FPDs) fabricated by milling, conventional, and different 3D printing fabrication techniques. METHODS A total sample of 160, 3-unit FPDs were subdivided into four groups; subtractive milled resin (SM), two 3D printed resins (Stereolithography; SLA and Digital Light Processing; DLP) and conventional self-cured polymethyl methacrylate resin (CM). Surface roughness (Ra) was assessed twice; at baseline (Ra1) and after artificial tooth brushing (Ra2). Color of the samples was measured after immersion in four different solutions (cola, coffee, black tea and distilled water) at three time intervals (1, 7 and 30 days). Comparisons of the Ra and the color change (∆E00) were done using one-way ANOVA followed by multiple pairwise comparisons using Bonferroni adjusted significance level. Comparisons of the Ra at two stages (Ra1 and Ra2) were done using paired t-test. Univariate linear regression was performed followed by multivariable regression to assess the association between ∆E00 and different factors (materials, solution, and time). Significance was set at P value <0.05. RESULTS The highest change in Ra following artificial tooth brushing was reported in the CM group, while the lowest change was reported in the SM group, with a significant difference between both groups (P<0.001). SM group had significantly lower ∆E00 than the CM group followed by 3D printed SLA and DLP groups (P<0.001). Storage in coffee for 30 days showed the highest ∆E00 values (P<0.001). CONCLUSIONS SM resin showed the least surface roughness and color change followed by 3D printed SLA resin. The difference in printing technology affected the tested properties with improved readings of 3D printed SLA resin. CLINICAL SIGNIFICANCE Milled provisional FPDs showed higher surface smoothness and color stability than those fabricated by SLA printing technology, but with no significant difference between both groups. Therefore, SLA printed resins can be an adequate substitute to milled resins in the fabrication of provisional FPDs to overcome the high expenses of milled provisional FPDs.
Collapse
Affiliation(s)
- Passent Ellakany
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia.
| | - Shaimaa M Fouda
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Maram A AlGhamdi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Nourhan M Aly
- Department of Pediatric Dentistry and Dental Public Health, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| |
Collapse
|
15
|
Alkhateeb RI, Algaoud HS, Aldamanhori RB, Alshubaili RR, Alalawi H, Gad MM. Fracture Load of 3D-Printed Interim Three-Unit Fixed Dental Prostheses: Impact of Printing Orientation and Post-Curing Time. Polymers (Basel) 2023; 15:polym15071737. [PMID: 37050351 PMCID: PMC10097162 DOI: 10.3390/polym15071737] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Revised: 03/28/2023] [Accepted: 03/29/2023] [Indexed: 04/03/2023] Open
Abstract
The fracture resistance of 3-unit interim fixed dental prostheses (IFDPs) fabricated using digital light processing (DLP) additive technology with different printing parameters is neglected. Therefore, this study investigates the effect of different printing orientations and different post-curing times on the fracture resistance of 3-unit IFDPs fabricated from two three-dimensional (3D) printed resins, NextDent, C&B (CB), ASIGA, and DentaTOOTH. A 3-unit dye was scanned, and an IFDP was designed. A total of 300 specimens (150/materials, n = 10) were printed and divided into three groups according to printing orientations (0°, 45°, 90°) per material. Each orientation was subdivided into five groups (n = 10) considering the post-curing time (green state as control, 30, 60, 90, and 120 min). All specimens underwent thermocycling (5000 cycles). Each specimen was fitted onto the die and loaded until fracture using a universal testing machine with a loading rate of 1 m/min. Data were analyzed using ANOVA and post hoc Tukey test (α = 0.05). The result showed that printing orientation had a significant effect on the fracture load for both ASIGA and NextDent materials (p < 0.05). The highest fracture load was recorded with 45° orientation, followed by 0° orientation and 90° orientation showed the lowest values per respective post-curing time. Post-curing time increased the fracture load (p < 0.05). Post-curing time had a positive effect on the fracture load. As the post-curing time increased, the fracture resistance load increased (p < 0.05), with 90 and 120 min showing the highest fracture load. The 0° and 45° printing orientations have a high fracture load for 3D-printed IFDPs, and an increased post-curing time is recommended.
Collapse
Affiliation(s)
- Reem I. Alkhateeb
- College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia
| | - Hadeel S. Algaoud
- College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia
| | - Rand B. Aldamanhori
- College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia
| | - Rand R. Alshubaili
- College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia
| | - Haidar Alalawi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia
| | - Mohammed M. Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia
| |
Collapse
|
16
|
Egan PF. Special Issue Editorial: Applications of 3D Printing for Polymers. Polymers (Basel) 2023; 15:polym15071638. [PMID: 37050252 PMCID: PMC10097040 DOI: 10.3390/polym15071638] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Accepted: 03/21/2023] [Indexed: 03/29/2023] Open
Abstract
Polymer 3D printing is an emerging technology highly relevant in diverse industries, including medicine, electronics, and robotics [...]
Collapse
Affiliation(s)
- Paul F Egan
- Mechanical Engineering, Texas Tech University, Lubbock, TX 79409, USA
| |
Collapse
|
17
|
Sun Q, Tang Y, Dai L, Tang Z, Zhou W, Wu T, Ji G. Serum Bile Acid Metabolites Predict the Therapeutic Effect of Mesalazine in Patients with Ulcerative Colitis. J Proteome Res 2023; 22:1287-1297. [PMID: 36921116 DOI: 10.1021/acs.jproteome.2c00820] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/17/2023]
Abstract
Ulcerative colitis (UC) is a systematic chronic disease characterized by insufficient intestinal absorption, and mesalazine is a common medical treatment. In the present study, 20 normal healthy controls (NC group), 10 unmedicated UC patients (UC group), and 20 mesalazine-responsive and 20 mesalazine-nonresponsive UC patients were recruited. A total of 42 serum BA metabolites, including 8 primary bile acids and 34 secondary bile acids (SBAs), were quantitatively measured. Compared with the NC group, serum SBAs in the UC patients were significantly lower but increased after mesalazine therapy. Differences in the serum TDCA, DCA, GDCA-3S, 12-keto LCA, and GCDCA-3S metabolites were found between the UC and NC groups, with AUC values of 0.777, 0.800, 0.815, 0.775, and 0.740, respectively. Furthermore, we identified 12-keto LCA as a specific BA marker of UC and BA biomarkers of mesalazine responsiveness. It was concluded that serum SBAs were decreased in UC patients, and TDCA, DCA, GDCA-3S, 12-keto LCA, and GCDCA-3S might aid in the diagnosis of UC. The abundance of SBAs increased after the mesalazine therapy, and serum 12-keto LCA was identified as an alternative invasive biomarker associated with UC diagnosis and therapeutic response, thereby providing a new approach for the prediction of response to mesalazine therapy in UC patients.
Collapse
Affiliation(s)
- Qiaoli Sun
- Institute of Digestive Disease, Longhua Hospital, Shanghai University of Traditional Chinese Medicine, South Wanping Road 725, Shanghai 200032, China
| | - Yingjue Tang
- Institute of Digestive Disease, Longhua Hospital, Shanghai University of Traditional Chinese Medicine, South Wanping Road 725, Shanghai 200032, China
| | - Liang Dai
- Institute of Digestive Disease, Longhua Hospital, Shanghai University of Traditional Chinese Medicine, South Wanping Road 725, Shanghai 200032, China.,Clinical Research Institute, Peking University Shenzhen Hospital, Shenzhen 518036, China
| | - Zhipeng Tang
- Institute of Digestive Disease, Longhua Hospital, Shanghai University of Traditional Chinese Medicine, South Wanping Road 725, Shanghai 200032, China
| | - Wenjun Zhou
- Institute of Digestive Disease, Longhua Hospital, Shanghai University of Traditional Chinese Medicine, South Wanping Road 725, Shanghai 200032, China
| | - Tao Wu
- Institute of Interdisciplinary Integrative Medicine Research, Shanghai University of Traditional Chinese Medicine, Cailun Road 1200, Shanghai 201203, China
| | - Guang Ji
- Institute of Digestive Disease, Longhua Hospital, Shanghai University of Traditional Chinese Medicine, South Wanping Road 725, Shanghai 200032, China
| |
Collapse
|
18
|
Son M, Raju K, Lee J, Jung J, Jeong S, Kim JI, Cho J. 3D Printing of CNT- and YSZ-Added Dental Resin-Based Composites by Digital Light Processing and Their Mechanical Properties. MATERIALS (BASEL, SWITZERLAND) 2023; 16:1873. [PMID: 36902988 PMCID: PMC10004184 DOI: 10.3390/ma16051873] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Revised: 02/22/2023] [Accepted: 02/23/2023] [Indexed: 06/18/2023]
Abstract
This study demonstrates the successful 3D printing of dental resin-based composites (DRCs) containing ceramic particles using the digital light processing (DLP) technique. The mechanical properties and oral rinsing stability of the printed composites were evaluated. DRCs have been extensively studied for restorative and prosthetic dentistry due to their clinical performance and aesthetic quality. They are often subjected to periodic environmental stress, and thus can easily undergo undesirable premature failure. Here, we investigated the effects of two different high-strength and biocompatible ceramic additives, carbon nanotube (CNT) and yttria-stabilized zirconia (YSZ), on the mechanical properties and oral rinsing stabilities of DRCs. Dental resin matrices containing different wt.% of CNT or YSZ were printed using the DLP technique after analyzing the rheological behavior of slurries. Mechanical properties such as Rockwell hardness and flexural strength, as well as the oral rinsing stability of the 3D-printed composites, were systematically investigated. The results indicated that a DRC with 0.5 wt.% YSZ exhibits the highest hardness of 19.8 ± 0.6 HRB and a flexural strength flexural strength of 50.6 ± 6 MPa, as well as reasonable oral rinsing steadiness. This study provides a fundamental perspective for designing advanced dental materials containing biocompatible ceramic particles.
Collapse
|
19
|
Cao UMN, Zhang Y, Chen J, Sayson D, Pillai S, Tran SD. Microfluidic Organ-on-A-chip: A Guide to Biomaterial Choice and Fabrication. Int J Mol Sci 2023; 24:3232. [PMID: 36834645 PMCID: PMC9966054 DOI: 10.3390/ijms24043232] [Citation(s) in RCA: 25] [Impact Index Per Article: 25.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Revised: 01/29/2023] [Accepted: 02/01/2023] [Indexed: 02/09/2023] Open
Abstract
Organ-on-A-chip (OoAC) devices are miniaturized, functional, in vitro constructs that aim to recapitulate the in vivo physiology of an organ using different cell types and extracellular matrix, while maintaining the chemical and mechanical properties of the surrounding microenvironments. From an end-point perspective, the success of a microfluidic OoAC relies mainly on the type of biomaterial and the fabrication strategy employed. Certain biomaterials, such as PDMS (polydimethylsiloxane), are preferred over others due to their ease of fabrication and proven success in modelling complex organ systems. However, the inherent nature of human microtissues to respond differently to surrounding stimulations has led to the combination of biomaterials ranging from simple PDMS chips to 3D-printed polymers coated with natural and synthetic materials, including hydrogels. In addition, recent advances in 3D printing and bioprinting techniques have led to the powerful combination of utilizing these materials to develop microfluidic OoAC devices. In this narrative review, we evaluate the different materials used to fabricate microfluidic OoAC devices while outlining their pros and cons in different organ systems. A note on combining the advances made in additive manufacturing (AM) techniques for the microfabrication of these complex systems is also discussed.
Collapse
Affiliation(s)
| | | | | | | | | | - Simon D. Tran
- McGill Craniofacial Tissue Engineering and Stem Cells Laboratory, Faculty of Dental Medicine and Oral Health Sciences, McGill University, 3640 University Street, Montreal, QC H3A 0C7, Canada
| |
Collapse
|
20
|
Wada J, Wada K, Gibreel M, Wakabayashi N, Iwamoto T, Vallittu PK, Lassila L. Effect of Surface Polishing on Physical Properties of an Occlusal Splint Material for Additive Manufacturing under Protection Gas Post-Curing Condition. Polymers (Basel) 2023; 15:polym15030625. [PMID: 36771926 PMCID: PMC9919341 DOI: 10.3390/polym15030625] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Accepted: 01/19/2023] [Indexed: 01/27/2023] Open
Abstract
The aim of this study was to evaluate the effect of surface polishing as well as the post-curing atmospheres (air and nitrogen gas) on the physical properties of an occlusal splint material for additive manufacturing. Flexural strength, flexural modulus, Vickers hardness number (VHN), degree of carbon double bond conversion (DC), water sorption (WSP), and water solubility (WSL) were evaluated. Surface polishing significantly affected the evaluated properties. Regardless of the post-curing atmosphere, flexural strength, flexural modulus, VHN, and DC showed significantly higher values for the polished specimens when compared with the unpolished ones, while WSP and WSL were significantly lower for the polished specimens. Unpolished specimens post-cured at nitrogen gas showed significantly higher VHN and DC values. However, the effect of the post-curing at a nitrogen gas atmosphere was non-significant in polished specimens. The current results suggested that surface polishing plays a role in the physical properties of the evaluated occlusal splint material and can enhance all the evaluated properties regardless of the post-curing atmosphere. Meanwhile, the post-curing at a nitrogen gas atmosphere can enhance the VHN and DC but its effect is confined only to the surface layers, which can be removed during surface polishing.
Collapse
Affiliation(s)
- Junichiro Wada
- Department of Biomaterials Science, Turku Clinical Biomaterials Centre–TCBC, Institute of Dentistry, University of Turku, Itäinen Pitkäkatu 4B, 20520 Turku, Finland
- Department of Advanced Prosthodontics, Tokyo Medical and Dental University–TMDU, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113–8510, Japan
- Correspondence: (J.W.); (L.L.); Tel.: +81-358035515 (J.W.)
| | - Kanae Wada
- Department of Biomaterials Science, Turku Clinical Biomaterials Centre–TCBC, Institute of Dentistry, University of Turku, Itäinen Pitkäkatu 4B, 20520 Turku, Finland
- Department of Pediatric Dentistry/Special Needs Dentistry, Tokyo Medical and Dental University–TMDU, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113–8510, Japan
| | - Mona Gibreel
- Department of Biomaterials Science, Turku Clinical Biomaterials Centre–TCBC, Institute of Dentistry, University of Turku, Itäinen Pitkäkatu 4B, 20520 Turku, Finland
| | - Noriyuki Wakabayashi
- Department of Advanced Prosthodontics, Tokyo Medical and Dental University–TMDU, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113–8510, Japan
| | - Tsutomu Iwamoto
- Department of Pediatric Dentistry/Special Needs Dentistry, Tokyo Medical and Dental University–TMDU, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113–8510, Japan
| | - Pekka K. Vallittu
- Department of Biomaterials Science, Turku Clinical Biomaterials Centre–TCBC, Institute of Dentistry, University of Turku, Itäinen Pitkäkatu 4B, 20520 Turku, Finland
- Wellbeing Services County of South-West Finland, Lemminkäisenkatu 23, 20520 Turku, Finland
| | - Lippo Lassila
- Department of Biomaterials Science, Turku Clinical Biomaterials Centre–TCBC, Institute of Dentistry, University of Turku, Itäinen Pitkäkatu 4B, 20520 Turku, Finland
- Correspondence: (J.W.); (L.L.); Tel.: +81-358035515 (J.W.)
| |
Collapse
|
21
|
Ellakany P, Madi M, Aly NM, Alshehri T, Alameer ST, Al-Harbi FA. Influences of Different CAD/CAM Ceramic Compositions and Thicknesses on the Mechanical Properties of Ceramic Restorations: An In Vitro Study. MATERIALS (BASEL, SWITZERLAND) 2023; 16:ma16020646. [PMID: 36676383 PMCID: PMC9865408 DOI: 10.3390/ma16020646] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Revised: 12/24/2022] [Accepted: 12/26/2022] [Indexed: 05/14/2023]
Abstract
The aim of this study was to assess the influences of different CAD/CAM ceramic compositions and thicknesses on the surface roughness and hardness of ceramic restorations. Four different ceramics were used in the current study: lithium disilicate (LD), leucite reinforced (LE), advanced lithium disilicate (ALD), and zirconia-reinforced lithium silicate (ZLS). Each group included 30 specimens subdivided into three different ceramic thicknesses (0.5, 1 and 1.5 mm thicknesses). The microhardness was measured for all the specimens using a microhardness testing machine, while the surface roughness was measured using a non-contact optical profilometer at three intervals (before toothbrushing and after toothbrushing, with and without toothpaste). Three-way and two-way ANOVA were used to determine the factors influencing the surface roughness and microhardness. There was a significant difference in the surface roughness between the studied groups for all the thicknesses. The findings showed that ALD had the lowest surface roughness, while ZLS showed the highest surface roughness. Moreover, ALD, followed by ZLS, had the highest hardness, while LD and LE had the lowest hardness values. Regarding the thicknesses, both the 0.5 and 1 mm ceramic thicknesses showed a significantly lower surface roughness than the 1.5 mm thickness, while the 1.5 mm thickness showed a significantly higher microhardness than the 0.5 mm thickness. The surface roughness and hardness were significantly affected by the ceramic composition and type of filler. It is recommended to use 1.5 mm-thick ceramic materials for the fabrication of definitive full-coverage ceramic restorations, while veneers require 0.5 mm-thick materials. ALD is a promising CAD/CAM material that can be used for the fabrication of restorations with a proper strength in both anterior and posterior regions.
Collapse
Affiliation(s)
- Passent Ellakany
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
- Correspondence: ; Tel.: +966-547812107
| | - Marwa Madi
- Department of Preventive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| | - Nourhan M. Aly
- Department of Pediatric Dentistry and Dental Public Health, Faculty of Dentistry, Alexandria University, Alexandria 21527, Egypt
| | - Turki Alshehri
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| | - Shahad T. Alameer
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| | - Fahad A. Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| |
Collapse
|