1
|
Souza LFB, Pires TS, Kist PP, Valandro LF, Moraes RR, Özcan M, Pereira GKR. 3D printed, subtractive, and conventional acrylic resins: Evaluation of monotonic versus fatigue behavior and surface characteristics. J Mech Behav Biomed Mater 2024; 155:106556. [PMID: 38676972 DOI: 10.1016/j.jmbbm.2024.106556] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Revised: 04/01/2024] [Accepted: 04/17/2024] [Indexed: 04/29/2024]
Abstract
This study assessed the mechanical properties and surface characteristics of dental prosthetic acrylic resin fabricated by 3D printing, comparing it with subtractive, pressing, and molding techniques. Bar-shaped specimens (N= 90; 65 × 10 × 3.3 mm; ISO:207951) were prepared and assigned into six groups: PRINT (3D printing vis stereolithography with PriZma 3D Bio Denture, Makertech Labs); SUB (subtractive manufacturing with Vipiblock Trilux, Vipi); PRESS Base (pressing using muffle with Thermo Vipi Wave, Vipi for base); PRESS Tooth (pressing with Onda-cryl, Clássico for tooth); MOLD Base (molding using addition silicone with Vipi Flash, Vipi for base); and MOLD Tooth (molding with Dencor, Clássico for tooth). Monotonic flexural strength (FS) and elastic modulus (E) were measured using a three-point bending approach (n= 5) on a universal testing machine at a crosshead speed of 5 mm/min. Fatigue testing (n= 10) followed similar geometry and settings, with a frequency of 2 Hz, initial stress level at 20 MPa, and stress increments of 5 MPa every 2,500 cycles. Surface roughness (n= 10) was assessed through profilometry, and fractographic and topographic analyses were conducted. Statistical analyses included One-Way ANOVA for monotonic FS, roughness, and E, along with Kaplan-Meier with Mantel-Cox post-hoc and Weibull analysis for fatigue strength. PRINT showed lower monotonic FS than the SUB and PRESS Tooth but comparable fatigue strength to these groups and superior to PRESS Base and MOLD (Base and Tooth) groups. All groups had similar Weibull moduli. Surface roughness of the PRINT group was comparable to most techniques but higher than the PRESS Tooth group. Fractographic analysis revealed fractures originating from surface defects under tensile stress, with SEM showing scratch patterns in all groups except PRINT, which had a more uniform surface. Despite its lower monotonic strength, 3D printed resin demonstrated comparable fatigue strength to subtractive and pressing methods and similar surface roughness to most methods, indicating its potential as a viable option for dental prosthesis.
Collapse
Affiliation(s)
- Luiza Freitas Brum Souza
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Center for Development of Advanced Materials, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Telma Souza Pires
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Center for Development of Advanced Materials, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Priscila Pauli Kist
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Center for Development of Advanced Materials, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Luiz Felipe Valandro
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Center for Development of Advanced Materials, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Rafael R Moraes
- Post-Graduate Program in Dentistry, Faculty of Dentistry, Federal University of Pelotas, Pelotas, RS, Brazil.
| | - Mutlu Özcan
- Clinic for Masticatory Disorders and Dental Biomaterials, Center for Dental Medicine, University of Zurich, 8032, Zurich, Switzerland.
| | - Gabriel Kalil Rocha Pereira
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Center for Development of Advanced Materials, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
2
|
Saini RS, Binduhayyim RIH, Gurumurthy V, Alshadidi AAF, Bavabeedu SS, Vyas R, Dermawan D, Naseef PP, Mosaddad SA, Heboyan A. In silico assessment of biocompatibility and toxicity: molecular docking and dynamics simulation of PMMA-based dental materials for interim prosthetic restorations. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2024; 35:28. [PMID: 38833196 DOI: 10.1007/s10856-024-06799-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2024] [Accepted: 05/09/2024] [Indexed: 06/06/2024]
Abstract
AIM This study aimed to comprehensively assess the biocompatibility and toxicity profiles of poly(methyl methacrylate) (PMMA) and its monomeric unit, methyl methacrylate (MMA), crucial components in dental materials for interim prosthetic restorations. METHODOLOGY Molecular docking was employed to predict the binding affinities, energetics, and steric features of MMA and PMMA with selected receptors involved in bone metabolism and tissue development, including RANKL, Fibronectin, BMP9, NOTCH2, and other related receptors. The HADDOCK standalone version was utilized for docking calculations, employing a Lamarckian genetic algorithm to explore the conformational space of ligand-receptor interactions. Furthermore, molecular dynamics (MD) simulations over 100 nanoseconds were conducted using the GROMACS package to evaluate dynamic actions and structural stability. The LigandScout was utilized for pharmacophore modeling, which employs a shape-based screening approach to identify potential ligand binding sites on protein targets. RESULTS The molecular docking studies elucidated promising interactions between PMMA and MMA with key biomolecular targets relevant to dental applications. MD simulation results provided strong evidence supporting the structural stability of PMMA complexes over time. Pharmacophore modeling highlighted the significance of carbonyl and hydroxyl groups as pharmacophoric features, indicating compounds with favorable biocompatibility profiles. CONCLUSION This study underscores the potential of PMMA in dental applications, emphasizing its structural stability, molecular interactions, and safety considerations. These findings lay a foundation for future advancements in dental biomaterials, guiding the design and optimization of materials for enhanced biocompatibility. Future directions include experimental validation of computational findings and the development of PMMA-based dental materials with improved biocompatibility and clinical performance.
Collapse
Affiliation(s)
- Ravinder S Saini
- Department of Dental Technology, COAMS, King Khalid University, Abha, Saudi Arabia
| | | | | | | | - Shashit Shetty Bavabeedu
- Department of Restorative Dentistry, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Rajesh Vyas
- Department of Dental Technology, COAMS, King Khalid University, Abha, Saudi Arabia
| | - Doni Dermawan
- Department of Chemistry, Warsaw University of Technology, Warsaw, Poland
| | | | - Seyed Ali Mosaddad
- Department of Research Analytics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, India.
- Student Research Committee, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran.
| | - Artak Heboyan
- Department of Research Analytics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, India.
- Department of Prosthodontics, Faculty of Stomatology, Yerevan State Medical University after Mkhitar Heratsi, Yerevan, Armenia.
- Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
3
|
Rajeev A, Kansara K, Bhatia D. Navigating the challenges and exploring the perspectives associated with emerging novel biomaterials. Biomater Sci 2024. [PMID: 38832912 DOI: 10.1039/d4bm00376d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/06/2024]
Abstract
The field of biomaterials is a continuously evolving interdisciplinary field encompassing biological sciences, materials sciences, chemical sciences, and physical sciences with a multitude of applications realized every year. However, different biomaterials developed for different applications have unique challenges in the form of biological barriers, and addressing these challenges simultaneously is also a challenge. Nevertheless, immense progress has been made through the development of novel materials with minimal adverse effects such as DNA nanostructures, specific synthesis strategies based on supramolecular chemistry, and modulating the shortcomings of existing biomaterials through effective functionalization techniques. This review discusses all these aspects of biomaterials, including the challenges at each level of their development and application, proposed countermeasures for these challenges, and some future directions that may have potential benefits.
Collapse
Affiliation(s)
- Ashwin Rajeev
- Department of Biosciences and Bioengineering, Indian Institute of Technology Gandhinagar, Palaj, Gandhinagar, Gujarat - 382355, India.
| | - Krupa Kansara
- Department of Biosciences and Bioengineering, Indian Institute of Technology Gandhinagar, Palaj, Gandhinagar, Gujarat - 382355, India.
| | - Dhiraj Bhatia
- Department of Biosciences and Bioengineering, Indian Institute of Technology Gandhinagar, Palaj, Gandhinagar, Gujarat - 382355, India.
| |
Collapse
|
4
|
Hampe T, Liersch J, Wiechens B, Bürgers R, Krohn S. Bisphenol A release from CAD/CAM splint materials. Eur J Oral Sci 2024:e12993. [PMID: 38778467 DOI: 10.1111/eos.12993] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Accepted: 04/26/2024] [Indexed: 05/25/2024]
Abstract
This study aimed to investigate the bisphenol A (BPA) release from four CAD/CAM splint materials: three polycarbonate-based (DD BioSplint C, Splint Plus Biostar, Temp Premium Flexible) and one polymethylmethacrylate-based (Temp Basic) material. From each material, ten cylindrical samples (n = 40) were immersed in high-performance liquid chromatography (HPLC) grade water following ISO 10993-12 and incubated for 24 h in an incubation shaker at 37°C and 112 rpm. Following BPA derivatization, analysis was performed by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). After 24 h of incubation, all investigated materials released significant amounts of BPA compared to water blanks. The material-dependent elution increased in the following order: DD BioSplint C < Splint Plus Biostar < Temp Basic < Temp Premium Flexible. Subtracting extraneous BPA, the concentrations ranged between 2.27 ng/mL and 12.65 ng/mL. After extrapolating the concentrations in relation to the average surface area of occlusal splints, the amount of BPA per mL exceeded the Tolerable Daily Intake (TDI) set by the European Union for a person weighing 70 kg by 1.32-6.16 times. Contrary to the release from previously investigated materials, BPA elution from CAD/CAM splint materials was highly elevated. Considering the increasing adaptation of CAD/CAM techniques, elution from them may represent a relevant BPA source in daily dental practice.
Collapse
Affiliation(s)
- Tristan Hampe
- Department of Prosthodontics, University Medical Center Göttingen, Göttingen, Germany
| | - Julia Liersch
- Department of Prosthodontics, University Medical Center Göttingen, Göttingen, Germany
| | - Bernhard Wiechens
- Department of Prosthodontics, University Medical Center Göttingen, Göttingen, Germany
- Department of Orthodontics, University Medical Center Göttingen, Göttingen, Germany
| | - Ralf Bürgers
- Department of Prosthodontics, University Medical Center Göttingen, Göttingen, Germany
| | - Sebastian Krohn
- Department of Prosthodontics, University Medical Center Göttingen, Göttingen, Germany
- Department of Orthodontics, University Hospital Regensburg, Regensburg, Germany
| |
Collapse
|
5
|
Binaljadm TM. Flexible Denture: A Literature Review. Cureus 2024; 16:e55425. [PMID: 38567238 PMCID: PMC10985649 DOI: 10.7759/cureus.55425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/03/2024] [Indexed: 04/04/2024] Open
Abstract
Careful consideration of material properties used to construct denture base material in removable partial dentures (RPDs) is required for a successful outcome. Because of nylon's flexible nature, nylon denture bases are a widely used alternative material to polymethyl methacrylate (PMMA) in RPDs. Flexible dentures help with retention by creating a seal around the denture's border. In this study, we review current evidence on flexible dentures and provide an overview of their uses, advantages, and disadvantages. We conducted electronic research of English-language articles written between 2018 and 2023 that addressed the different physical and mechanical properties of flexible dentures. Flexible dentures' water sorption did not exceed ISO standards. Other physical properties we investigated, such as color stability and polymerization shrinkage, were lower in flexible dentures than in PMMA. Mechanical properties showed a lower value compared to PMMA, such as surface roughness and hardness, and impact strength. However, flexural strength was controversial. Retention was better in PMMA compared to flexible dentures. Finally, the retention of acrylic teeth compared to flexible dentures was better with the provision of extra mechanical retention means. Therefore, it is important to examine flexible dentures' properties, indications, advantages, and disadvantages when offering patients this solution.
Collapse
Affiliation(s)
- Tahani M Binaljadm
- Substitutive Dental Sciences Department, College of Dentistry, Taibah University, Madinah, SAU
| |
Collapse
|
6
|
Vuksic J, Pilipovic A, Poklepovic Pericic T, Kranjcic J. The Influence of Contemporary Denture Base Fabrication Methods on Residual Monomer Content, Flexural Strength and Microhardness. MATERIALS (BASEL, SWITZERLAND) 2024; 17:1052. [PMID: 38473524 DOI: 10.3390/ma17051052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Revised: 02/19/2024] [Accepted: 02/22/2024] [Indexed: 03/14/2024]
Abstract
(1) Background: Digital technologies are available for denture base fabrication, but there is a lack of scientific data on the mechanical and chemical properties of the materials produced in this way. Therefore, the aim of this study was to investigate the residual monomer content, flexural strength and microhardness of denture base materials as well as correlations between investigated parameters. (2) Methods: Seven denture base materials were used: one conventional heat cured polymethyl methacrylate, one polyamide, three subtractive manufactured materials and two additive manufactured materials. High-performance liquid chromatography was used to determine residual monomer content and the test was carried out in accordance with the specification ISO No. 20795-1:2013. Flexural strength was also determined according to the specification ISO No. 20795-1:2013. The Vickers method was used to investigate microhardness. A one-way ANOVA with a Bonferroni post-hoc test was used for the statistical analysis. The Pearson correlation test was used for the correlation analysis. (3) Results: There was a statistically significant difference between the values of residual monomer content of the different denture base materials (p < 0.05). Anaxdent pink blank showed the highest value of 3.2% mass fraction, while Polident pink CAD-CAM showed the lowest value of 0.05% mass fraction. The difference between the flexural strength values of the different denture base materials was statistically significant (p < 0.05), with values ranging from 62.57 megapascals (MPa) to 103.33 MPa. The difference between the microhardness values for the different denture base materials was statistically significant (p < 0.05), and the values obtained ranged from 10.61 to 22.86 Vickers hardness number (VHN). A correlation was found between some results for the material properties investigated (p < 0.05). (4) Conclusions: The selection of contemporary digital denture base manufacturing techniques may affect residual monomer content, flexural strength and microhardness but is not the only criterion for achieving favourable properties.
Collapse
Affiliation(s)
- Josip Vuksic
- Department of Removable Prosthodontics, University of Zagreb School of Dental Medicine, Gunduliceva 5, 10000 Zagreb, Croatia
- Department of Prosthodontics, University Hospital Dubrava, Av. Gojka Šuška 6, 10000 Zagreb, Croatia
| | - Ana Pilipovic
- University of Zagreb Faculty of Mechanical Engineering and Naval Architecture, Ivana Lučića 5, 10000 Zagreb, Croatia
| | | | - Josip Kranjcic
- Department of Prosthodontics, University Hospital Dubrava, Av. Gojka Šuška 6, 10000 Zagreb, Croatia
- Department of Fixed Prosthodontics, University of Zagreb School of Dental Medicine, Gunduliceva 5, 10000 Zagreb, Croatia
| |
Collapse
|
7
|
Dederichs M, Badr Z, Viebranz S, Schroeter S, Hennig CL, Schmelzer AS, Guentsch A. Effect of Different Primers on Shear Bond Strength of Base Metal Alloys and Zirconia Frameworks. Polymers (Basel) 2024; 16:572. [PMID: 38475255 DOI: 10.3390/polym16050572] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2024] [Revised: 02/16/2024] [Accepted: 02/18/2024] [Indexed: 03/14/2024] Open
Abstract
Ensuring a secure bond between a framework structure and layering composite resin veneer is essential for a long-lasting dental restoration. A variety of primer systems are available to facilitate the adhesive bonding. Nevertheless, the growing preference for efficiency and simplicity in dentistry has made the one-bottle universal primers a desirable option. This study aims to compare the effectiveness of universal primers on the shear bond strength (SBS) of base metal alloy (BMA) and zirconia to layering composite resin. Each 160 BMA and zirconia 20 × 10 × 5 mm test specimen was fabricated. Eight different primers (SunCera Metal Primer, Metal Primer Z, Reliance Metal Primer, Alloy Primer, MKZ Primer, Monobond Plus, ArtPrime Plus, and Clearfil Ceramic Primer Plus) were applied to 20 specimens in each group. Subsequently, a 5 × 2 mm composite resin build-up was applied. SBS tests were performed after 24 h of water storage and after thermocycling (25,000 cycles, 5-55 °C). On BMA, after water storage for 24 h, the bond strength values ranged from 26.53 ± 3.28 MPa (Metal Primer Z) to 29.72 ± 2.00 MPa (MKZ Primer), while after thermocycling, bond strength values ranged from 25.19 ± 1.73 MPa (MKZ Primer) to 27.69 ± 2.37 MPa (Clearfil Ceramic Primer Plus). On a zirconia base, after 24 h, the bond strengths values ranged from 22.63 ± 2.28 MPa (Reliance Primer) to 29.96 ± 2.37 MPa (MKZ Primer) and from 23.77 ± 3.86 MPa (Metal Primer Z) to 28.88 ± 3.09 MPa (Monobond Plus) after thermocycling. While no significant difference in bond strength was found between the primers on the BMA base, five primer combinations differed significantly from each other on zirconia (p = 0.002-0.043). All primers achieved a bond strength greater than 23 MPa on both framework materials after thermocycling. Thus, all primers tested can be applied to both framework materials with comparable results.
Collapse
Affiliation(s)
- Marco Dederichs
- Policlinic of Prosthetic Dentistry and Material Science, Center for Dental Medicine, Jena University Hospital, D-07743 Jena, Germany
| | - Zaid Badr
- Technological Innovation Center, Department of General Dental Sciences, Marquette University School of Dentistry, Milwaukee, WI 53201-1881, USA
| | - Stephanie Viebranz
- Policlinic of Prosthetic Dentistry and Material Science, Center for Dental Medicine, Jena University Hospital, D-07743 Jena, Germany
| | - Steffen Schroeter
- Policlinic of Prosthetic Dentistry and Material Science, Center for Dental Medicine, Jena University Hospital, D-07743 Jena, Germany
| | - Christoph-Ludwig Hennig
- Department of Orthodontics, Center for Dental Medicine, Jena University Hospital, D-07743 Jena, Germany
| | - Anne-Sophie Schmelzer
- Policlinic of Prosthetic Dentistry and Material Science, Center for Dental Medicine, Jena University Hospital, D-07743 Jena, Germany
| | - Arndt Guentsch
- Department of Surgical and Diagnostic Sciences, Marquette University School of Dentistry, Milwaukee, WI 53201-1881, USA
| |
Collapse
|
8
|
Jurado CA, Azpiazu-Flores FX, Fu CC, Rojas-Rueda S, Guzman-Perez G, Floriani F. Expediting the Rehabilitation of Severely Resorbed Ridges Using a Combination of CAD-CAM and Analog Techniques: A Case Report. MEDICINA (KAUNAS, LITHUANIA) 2024; 60:260. [PMID: 38399547 PMCID: PMC10890117 DOI: 10.3390/medicina60020260] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Revised: 01/29/2024] [Accepted: 01/31/2024] [Indexed: 02/25/2024]
Abstract
With the life expectancy increasing, there is a growing need for prosthetic dental treatments to restore the oral health, function, and quality of life of edentulous patients. Presently, only a few articles are available describing the oral rehabilitation of patients with severely resorbed ridges with milled complete dentures. This clinical case report provides a straightforward protocol consisting of a combination of analog and digital techniques for the rehabilitation of edentulous patients with severely resorbed ridges with milled fixed and removable complete dentures. This technique permits the minimization of the number of appointments, improves patient comfort, allows for the digital archiving of important clinical data, and permits the manufacture of prostheses with improved mechanical properties. These favorable outcomes were achieved by using the patient's existing PMMA complete denture as a custom tray for a final impression with light-bodied Polyvinylsiloxane. Subsequently, the resulting models were digitized, and a digital complete denture was designed and manufactured in an expedited manner using CAD-CAM techniques. Therefore, this case report highlights the potential of CAD/CAM technology to predictably restabilize oral functions and improve patients' quality of life.
Collapse
Affiliation(s)
- Carlos A. Jurado
- Department of Prosthodontics, College of Dentistry and Dental Clinics, The University of Iowa, Iowa City, IA 52242, USA
| | - Francisco X. Azpiazu-Flores
- Department of Restorative Dentistry, Gerald Niznick College of Dentistry, University of Manitoba, Winnipeg, MB R3E 3N4, Canada
- Center for Implant, Esthetic, and Innovative Dentistry, Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, IN 46202, USA
| | - Chin-Chuan Fu
- Department of Restorative Dentistry, University of Alabama at Birmingham School of Dentistry, Birmingham, AL 35233, USA
| | | | - Gerardo Guzman-Perez
- Department of Periodontology, Centro Educative Multidisciplinario en Rehabilitation Oral (CEMRO), Morelia 58880, Mexico
- Department of Periodontology, Quetzalcoatl University, Irapuato 36615, Mexico
| | - Franciele Floriani
- Department of Prosthodontics, College of Dentistry and Dental Clinics, The University of Iowa, Iowa City, IA 52242, USA
| |
Collapse
|
9
|
Elhmali HT, Stajcic I, Stajcic A, Pesic I, Jovanovic M, Petrovic M, Radojevic V. Influence of Novel SrTiO 3/MnO 2 Hybrid Nanoparticles on Poly(methyl methacrylate) Thermal and Mechanical Behavior. Polymers (Basel) 2024; 16:278. [PMID: 38276687 PMCID: PMC10820619 DOI: 10.3390/polym16020278] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2023] [Revised: 12/30/2023] [Accepted: 12/30/2023] [Indexed: 01/27/2024] Open
Abstract
While dental poly methyl methacrylate(PMMA) possesses distinctive qualities such as ease of fabrication, cost-effectiveness, and favorable physical and mechanical properties, these attributes alone are inadequate to impart the necessary impact strength and hardness. Consequently, pure PMMA is less suitable for dental applications. This research focused on the incorporation of Strontium titanate (SrTiO3-STO) and hybrid filler STO/Manganese oxide (MnO2) to improve impact resistance and hardness. The potential of STO in reinforcing PMMA is poorly investigated, while hybrid filler STO/MnO2 has not been presented yet. Differential scanning calorimetry is conducted in order to investigate the agglomeration influence on the PMMA glass transition temperature (Tg), as well as the leaching of residual monomer and volatile additives that could pose a threat to human health. It has been determined that agglomeration with 1 wt% loading had no influence on Tg, while the first scan revealed differences in evaporation of small molecules, in favor of composite PMMA-STO/MnO2, which showed the trapping potential of volatiles. Investigations of mechanical properties have revealed the significant influence of hybrid STO/MnO2 filler on microhardness and total absorbed impact energy, which were increased by 89.9% and 145.4%, respectively. Results presented in this study revealed the reinforcing potential of hybrid nanoparticles that could find application in other polymers as well.
Collapse
Affiliation(s)
- Houda Taher Elhmali
- Faculty of Technology and Metallurgy, University of Belgrade, 11000 Belgrade, Serbia; (H.T.E.); (M.J.); (M.P.); (V.R.)
| | - Ivana Stajcic
- Department of Physical Chemistry, “Vinča” Institute of Nuclear Sciences—National Institute of the Republic of Serbia, University of Belgrade, Mike Petrovića Alasa 12-14, P.O. Box 522, 11001 Belgrade, Serbia
| | - Aleksandar Stajcic
- Center for Microelectronic Technologies, Institute of Chemistry, Technology and Metallurgy—National Institute of the Republic of Serbia, University of Belgrade, 11000 Belgrade, Serbia; (A.S.); (I.P.)
| | - Ivan Pesic
- Center for Microelectronic Technologies, Institute of Chemistry, Technology and Metallurgy—National Institute of the Republic of Serbia, University of Belgrade, 11000 Belgrade, Serbia; (A.S.); (I.P.)
| | - Marija Jovanovic
- Faculty of Technology and Metallurgy, University of Belgrade, 11000 Belgrade, Serbia; (H.T.E.); (M.J.); (M.P.); (V.R.)
| | - Milos Petrovic
- Faculty of Technology and Metallurgy, University of Belgrade, 11000 Belgrade, Serbia; (H.T.E.); (M.J.); (M.P.); (V.R.)
| | - Vesna Radojevic
- Faculty of Technology and Metallurgy, University of Belgrade, 11000 Belgrade, Serbia; (H.T.E.); (M.J.); (M.P.); (V.R.)
| |
Collapse
|
10
|
Chander NG, Mahajan A. Comparison of cytotoxicity between 3D printable resins and heat-cure PMMA. J Oral Biol Craniofac Res 2024; 14:107-110. [PMID: 38304040 PMCID: PMC10831252 DOI: 10.1016/j.jobcr.2024.01.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 12/06/2023] [Accepted: 01/10/2024] [Indexed: 02/03/2024] Open
Abstract
Aim The aim of this study was to evaluate and compare the cytotoxicity of polyurethane and polyoxymethylene printable resins with conventional heat cure polymethyl methacrylate denture base resins. Methods The study followed ISO-10993-5 guidelines. It comprised of three groups. Fifteen cuboidal samples measuring 10x10 × 10mm dimension were prepared for each group. The polymethylmethacrylate samples were fabricated using conventional denture processing techniques, while the polyoxymethylene samples were printed using fused deposition modeling and the polyurethane samples using stereolithography technique. Post fabrication the samples were evaluated for cytotoxicity using the MTT assay with the VERO cell line. The percentage of cell viability was calculated to determine the cytotoxic effects. Results Statistical analysis revealed a significant difference in the cell viability of the experimental groups (p ≤ 0.0001). The polyoxymethylene group showed the highest % cell viability (62.78 %), followed by the polymethylmethacrylate group (52.43 %), and the least was observed in the polyurethane-based resin group (46.47 %). The findings indicate polyoxymethylene group displayed least cytotoxicity, followed by polymethylmethacrylate, and polyurethane-based resin. Conclusion Polyoxymethylene resin exhibited the minimum cytotoxic properties among the tested materials, followed by polymethylmethacrylate and polyurethane resin.
Collapse
Affiliation(s)
- N. Gopi Chander
- Department of Prosthodontics, SRM Dental College, Ramapuram, Chennai, 89, India
| | - Aashmika Mahajan
- Department of Prosthodontics, SRM Dental College, Ramapuram, Chennai, 89, India
| |
Collapse
|
11
|
Farghal AE. Fabrication of a Definitive Obturator for a Patient With a Maxillary Defect: A Case Report. Cureus 2023; 15:e50578. [PMID: 38222126 PMCID: PMC10788096 DOI: 10.7759/cureus.50578] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/15/2023] [Indexed: 01/16/2024] Open
Abstract
Maxillectomy defects can lead to oroantral communication, causing difficulties with chewing, swallowing, speech, and facial appearance. Prosthodontists play a crucial role in rehabilitating such defects using obturators. This case report presents the fabrication of a definitive obturator with a cast metal framework for a patient who had an acquired maxillary defect and previously experienced issues with an ill-fitting obturator. In this clinical report, the patient's canine teeth on both sides and the premolars and molars on the left side were used for rest placement. Retention was achieved by utilizing the remaining teeth, employing two embrasure Aker clasps on the left molars and premolars and a C-wrought wire clasp on the right canine. A complete palate was designed as the major connector to ensure optimal load distribution to the surrounding tissues. Additionally, an indirect retainer was planned for the right canine. This definitive prosthesis rehabilitated the patient, improving masticatory efficiency, enhancing speech clarity, and improving quality of life.
Collapse
Affiliation(s)
- Ahmad E Farghal
- Department of Substitutive Dental Sciences, Taibah University, Medina, SAU
| |
Collapse
|