1
|
Regalado-Méndez A, Zavaleta-Avendaño J, Peralta-Reyes E, Natividad R. Convex optimization for maximizing the degradation efficiency of chloroquine in a flow-by electrochemical reactor. J Solid State Electrochem 2023:1-14. [PMID: 37363394 PMCID: PMC10088624 DOI: 10.1007/s10008-023-05452-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Revised: 02/09/2023] [Accepted: 03/03/2023] [Indexed: 06/28/2023]
Abstract
The degradation efficiency of chloroquine phosphate (CQ), an anti-COVID-19 drug, was investigated in a flow-by electrochemical reactor (FBER) provided with two boron-doped diamond (BDD) electrodes (as cathode and anode) under batch recirculation mode. A central composite rotatable design (CCRD) was run down to model and assess the influence of initial pH in an interval of 3.71 to 11.28, the current density in an interval of 34.32 to 185.68 mA cm-2, and liquid volumetric flow rate in an interval of 0.58 to 1.42 L min-1, and conduct the convex optimization to obtain the maximum degradation efficiency. Experimental results were modeled through a second-order polynomial equation having a determination coefficient (R2) of 0.9705 with a variance coefficient of 1.1%. Optimal operating conditions found (initial pH of 5.38, current density (j) of 34.4 mA cm-2, and liquid flow rate (Q) of 1.42 L min-1) led to a global maximum degradation efficiency, COD removal efficiency, and mineralization efficiency of 89.3, 51.6 and 53.1%, respectively, with an energy consumption of 0.041 kWh L-1 within 9 h of treatment. Additionally, a pseudo-zero-order kinetic model was demonstrated to fit the experimental data and the calculated pseudo-zero-order kinetic constant (kapp) was 13.14 mg L-1 h-1 (2.54 × 10-5 mol dm-3 h-1). Furthermore, the total operating cost was of 0.47 US$ L-1. Finally, this research could be helpful for the treatment of wastewater containing an anti-COVID-19 drug such as CQ. Supplementary Information The online version contains supplementary material available at 10.1007/s10008-023-05452-7.
Collapse
Affiliation(s)
| | | | - Ever Peralta-Reyes
- Investigation Laboratories, Universidad del Mar, Puerto Ángel, 70902 Oaxaca, México
| | - Reyna Natividad
- Chemical Engineering Laboratory, Centro Conjunto de Investigación en Química Sustentable, UAEMex-UNAM, Universidad Autónoma del Estado de México, Estado de México, Toluca, 50200 México
| |
Collapse
|
3
|
Electrochemical Technologies to Decrease the Chemical Risk of Hospital Wastewater and Urine. Molecules 2021; 26:molecules26226813. [PMID: 34833906 PMCID: PMC8621562 DOI: 10.3390/molecules26226813] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2021] [Revised: 11/01/2021] [Accepted: 11/09/2021] [Indexed: 11/24/2022] Open
Abstract
The inefficiency of conventional biological processes to remove pharmaceutical compounds (PhCs) in wastewater is leading to their accumulation in aquatic environments. These compounds are characterized by high toxicity, high antibiotic activity and low biodegradability, and their presence is causing serious environmental risks. Because much of the PhCs consumed by humans are excreted in the urine, hospital effluents have been considered one of the main routes of entry of PhCs into the environment. In this work, a critical review of the technologies employed for the removal of PhCs in hospital wastewater was carried out. This review provides an overview of the current state of the developed technologies for decreasing the chemical risks associated with the presence of PhCs in hospital wastewater or urine in the last years, including conventional treatments (filtration, adsorption, or biological processes), advanced oxidation processes (AOPs) and electrochemical advanced oxidation processes (EAOPs).
Collapse
|
4
|
Torres NH, Santos GDOS, Romanholo Ferreira LF, Américo-Pinheiro JHP, Eguiluz KIB, Salazar-Banda GR. Environmental aspects of hormones estriol, 17β-estradiol and 17α-ethinylestradiol: Electrochemical processes as next-generation technologies for their removal in water matrices. CHEMOSPHERE 2021; 267:128888. [PMID: 33190907 DOI: 10.1016/j.chemosphere.2020.128888] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Revised: 11/02/2020] [Accepted: 11/04/2020] [Indexed: 06/11/2023]
Abstract
Hormones as a group of emerging contaminants have been increasingly used worldwide, which has increased their concern at the environmental level in various matrices, as they reach the water bodies through effluents due to the ineffectiveness of conventional treatments. Here we review the environmental scenario of hormones estriol (E3), 17β-estradiol (E2), and 17α-ethinylestradiol (EE2), explicitly their origins, their characteristics, interactions, how they reach the environment, and, above all, the severe pathological and toxicological damage to animals and humans they produce. Furthermore, studies for the treatment of these endocrine disruptors (EDCs) are deepened using electrochemical processes as the remediation methods of the respective hormones. In the reported studies, these micropollutants were detected in samples of surface water, underground, soil, and sediment at concentrations that varied from ng L-1 to μg L-1 and are capable of causing changes in the endocrine system of various organisms. However, although there are studies on the ecotoxicological effects concerning E3, E2, and EE2 hormones, little is known about their environmental dispersion and damage in quantitative terms. Moreover, biodegradation becomes the primary mechanism of removal of steroid estrogens removal by sewage treatment plants, but it is still inefficient, which shows the importance of studying electrochemically-driven processes such as the Electrochemical Advanced Oxidation Processes (EAOP) and electrocoagulation for the removal of emerging micropollutants. Thus, this review covers information on the occurrence of these hormones in various environmental matrices, their respective treatment, and effects on exposed organisms for ecotoxicology purposes.
Collapse
Affiliation(s)
- Nádia Hortense Torres
- Institute of Technology and Research (ITP), Tiradentes University (UNIT), Av. Murilo Dantas, 300, Farolândia, 49032-490, Aracaju, Sergipe, Brazil; Graduate Program in Process Engineering, Tiradentes University (UNIT), Av. Murilo Dantas, 300, Farolândia, 49032-490, Aracaju, Sergipe, Brazil.
| | - Géssica de Oliveira Santiago Santos
- Institute of Technology and Research (ITP), Tiradentes University (UNIT), Av. Murilo Dantas, 300, Farolândia, 49032-490, Aracaju, Sergipe, Brazil; Graduate Program in Process Engineering, Tiradentes University (UNIT), Av. Murilo Dantas, 300, Farolândia, 49032-490, Aracaju, Sergipe, Brazil
| | - Luiz Fernando Romanholo Ferreira
- Institute of Technology and Research (ITP), Tiradentes University (UNIT), Av. Murilo Dantas, 300, Farolândia, 49032-490, Aracaju, Sergipe, Brazil; Graduate Program in Process Engineering, Tiradentes University (UNIT), Av. Murilo Dantas, 300, Farolândia, 49032-490, Aracaju, Sergipe, Brazil
| | | | - Katlin Ivon Barrios Eguiluz
- Institute of Technology and Research (ITP), Tiradentes University (UNIT), Av. Murilo Dantas, 300, Farolândia, 49032-490, Aracaju, Sergipe, Brazil; Graduate Program in Process Engineering, Tiradentes University (UNIT), Av. Murilo Dantas, 300, Farolândia, 49032-490, Aracaju, Sergipe, Brazil
| | - Giancarlo Richard Salazar-Banda
- Institute of Technology and Research (ITP), Tiradentes University (UNIT), Av. Murilo Dantas, 300, Farolândia, 49032-490, Aracaju, Sergipe, Brazil; Graduate Program in Process Engineering, Tiradentes University (UNIT), Av. Murilo Dantas, 300, Farolândia, 49032-490, Aracaju, Sergipe, Brazil
| |
Collapse
|
5
|
Electrochemical Mineralization of Ibuprofen on BDD Electrodes in an Electrochemical Flow Reactor: Numerical Optimization Approach. Processes (Basel) 2020. [DOI: 10.3390/pr8121666] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
Statistical analysis was applied to optimize the electrochemical mineralization of ibuprofen with two boron-doped diamond (BDD) electrodes in a continuous electrochemical flow reactor under recirculation batch mode. A central composite rotatable (CCR) experimental design was used to analyze the effect of initial pH (2.95–13.04), current intensity (2.66–4.34 A), and volumetric flow rate (0.16–1.84 L/min) and further optimized by response surface methodology (RSM) to obtain the maximum mineralization efficiency and the minimum specific energy consumption. A 91.6% mineralization efficiency (EM) of ibuprofen with a specific energy consumption (EC) of 4.36 KW h/g TOC within 7 h of treatment was achieved using the optimized operating parameters (pH0 = 12.29, I = 3.26 A, and Q of 1 L/min). Experimental results of RSM were fitted via a third-degree polynomial regression equation having the performance index determination coefficients (R2) of 0.8658 and 0.8468 for the EM and EC, respectively. The reduced root-mean-square error (RMSE) was 0.1038 and 0.1918 for EM and EC, respectively. This indicates an efficient predictive performance to optimize the operating parameters of the electrochemical flow reactor with desirability of 0.9999993. Besides, it was concluded that the optimized conditions allow to achieve a high percentage of ibuprofen mineralization (91.6%) and a cost of 0.002 USD $/L. Therefore, the assessed process is efficient for wastewater remediation.”
Collapse
|