1
|
Singh M, Anvekar P, Baraskar B, Pallipamu N, Gadam S, Cherukuri ASS, Damani DN, Kulkarni K, Arunachalam SP. Prospective of Pancreatic Cancer Diagnosis Using Cardiac Sensing. J Imaging 2023; 9:149. [PMID: 37623681 PMCID: PMC10455647 DOI: 10.3390/jimaging9080149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 07/14/2023] [Accepted: 07/17/2023] [Indexed: 08/26/2023] Open
Abstract
Pancreatic carcinoma (Ca Pancreas) is the third leading cause of cancer-related deaths in the world. The malignancies of the pancreas can be diagnosed with the help of various imaging modalities. An endoscopic ultrasound with a tissue biopsy is so far considered to be the gold standard in terms of the detection of Ca Pancreas, especially for lesions <2 mm. However, other methods, like computed tomography (CT), ultrasound, and magnetic resonance imaging (MRI), are also conventionally used. Moreover, newer techniques, like proteomics, radiomics, metabolomics, and artificial intelligence (AI), are slowly being introduced for diagnosing pancreatic cancer. Regardless, it is still a challenge to diagnose pancreatic carcinoma non-invasively at an early stage due to its delayed presentation. Similarly, this also makes it difficult to demonstrate an association between Ca Pancreas and other vital organs of the body, such as the heart. A number of studies have proven a correlation between the heart and pancreatic cancer. The tumor of the pancreas affects the heart at the physiological, as well as the molecular, level. An overexpression of the SMAD4 gene; a disruption in biomolecules, such as IGF, MAPK, and ApoE; and increased CA19-9 markers are a few of the many factors that are noted to affect cardiovascular systems with pancreatic malignancies. A comprehensive review of this correlation will aid researchers in conducting studies to help establish a definite relation between the two organs and discover ways to use it for the early detection of Ca Pancreas.
Collapse
Affiliation(s)
- Mansunderbir Singh
- Department of Radiology, Mayo Clinic, Rochester, MN 55905, USA; (M.S.); (B.B.); (N.P.)
| | - Priyanka Anvekar
- Department of Medicine, Division of Infectious Diseases, Mayo Clinic, Rochester, MN 55905, USA;
| | - Bhavana Baraskar
- Department of Radiology, Mayo Clinic, Rochester, MN 55905, USA; (M.S.); (B.B.); (N.P.)
| | - Namratha Pallipamu
- Department of Radiology, Mayo Clinic, Rochester, MN 55905, USA; (M.S.); (B.B.); (N.P.)
| | - Srikanth Gadam
- Department of Radiology, Mayo Clinic, Rochester, MN 55905, USA; (M.S.); (B.B.); (N.P.)
| | - Akhila Sai Sree Cherukuri
- GIH Artificial Intelligence Laboratory (GAIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
- Microwave Engineering and Imaging Laboratory (MEIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
| | - Devanshi N. Damani
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN 55905, USA;
- Department of Internal Medicine, Texas Tech University Health Science Center, El Paso, TX 79995, USA
| | - Kanchan Kulkarni
- Centre de Recherche Cardio-Thoracique de Bordeaux, University of Bordeaux, INSERM, U1045, 33000 Bordeaux, France;
- IHU Liryc, Heart Rhythm Disease Institute, Fondation Bordeaux Université, 33600 Bordeaux, France
| | - Shivaram P. Arunachalam
- Department of Radiology, Mayo Clinic, Rochester, MN 55905, USA; (M.S.); (B.B.); (N.P.)
- GIH Artificial Intelligence Laboratory (GAIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
- Microwave Engineering and Imaging Laboratory (MEIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
- Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
| |
Collapse
|
2
|
Coyle-Asbil HJ, Habegger J, Oliver M, Vallis LA. Enabling the ActiGraph GT9X Link's Idle Sleep Mode and Inertial Measurement Unit Settings Directly Impacts Data Acquisition. SENSORS (BASEL, SWITZERLAND) 2023; 23:5558. [PMID: 37420725 DOI: 10.3390/s23125558] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Revised: 06/02/2023] [Accepted: 06/06/2023] [Indexed: 07/09/2023]
Abstract
The ActiGraph GT9X has been implemented in clinical trials to track physical activity and sleep. Given recent incidental findings from our laboratory, the overall aim of this study was to notify academic and clinical researchers of the idle sleep mode (ISM) and inertial measurement unit (IMU)'s interaction, as well as their subsequent effect on data acquisition. Investigations were undertaken using a hexapod robot to test the X, Y and Z sensing axes of the accelerometers. Seven GT9X were tested at frequencies ranging from 0.5 to 2 Hz. Testing was performed for three sets of setting parameters: Setting Parameter 1 (ISMONIMUON), Setting Parameter 2 (ISMOFFIMUON), Setting Parameter 3 (ISMONIMUOFF). The minimum, maximum and range of outputs were compared between the settings and frequencies. Findings indicated that Setting Parameters 1 and 2 were not significantly different, but both were significantly different from Setting Parameter 3. Upon inspection, it was discovered that the ISM was only active during Setting Parameter 3 testing, despite it being enabled in Setting Parameter 1. Researchers should be aware of this when conducting future research using the GT9X.
Collapse
Affiliation(s)
- Hannah J Coyle-Asbil
- Department of Human Health and Nutritional Sciences, University of Guelph, Guelph, ON N1G 2W1, Canada
| | - Janik Habegger
- School of Engineering, University of Guelph, Guelph, ON N1G 2W1, Canada
| | - Michele Oliver
- School of Engineering, University of Guelph, Guelph, ON N1G 2W1, Canada
| | - Lori Ann Vallis
- Department of Human Health and Nutritional Sciences, University of Guelph, Guelph, ON N1G 2W1, Canada
| |
Collapse
|
3
|
Rinderknecht MD, Zanon M, Boonstra TA, Angelini L, Stanev D, Chan GG, Bunn L, Dondelinger F, Hosking R, Freeman J, Hobart J, Marsden J, Craveiro L. An observational study to assess validity and reliability of smartphone sensor-based gait and balance assessments in multiple sclerosis: Floodlight GaitLab protocol. Digit Health 2023; 9:20552076231205284. [PMID: 37868156 PMCID: PMC10588425 DOI: 10.1177/20552076231205284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Accepted: 09/18/2023] [Indexed: 10/24/2023] Open
Abstract
Background Gait and balance impairments are often present in people with multiple sclerosis (PwMS) and have a significant impact on quality of life and independence. Gold-standard quantitative tools for assessing gait and balance such as motion capture systems and force plates usually require complex technical setups. Wearable sensors, including those integrated into smartphones, offer a more frequent, convenient, and minimally burdensome assessment of functional disability in a home environment. We developed a novel smartphone sensor-based application (Floodlight) that is being used in multiple research and clinical contexts, but a complete validation of this technology is still lacking. Methods This protocol describes an observational study designed to evaluate the analytical and clinical validity of Floodlight gait and balance tests. Approximately 100 PwMS and 35 healthy controls will perform multiple gait and balance tasks in both laboratory-based and real-world environments in order to explore the following properties: (a) concurrent validity of the Floodlight gait and balance tests against gold-standard assessments; (b) reliability of Floodlight digital measures derived under different controlled gait and balance conditions, and different on-body sensor locations; (c) ecological validity of the tests; and (d) construct validity compared with clinician- and patient-reported assessments. Conclusions The Floodlight GaitLab study (ISRCTN15993728) represents a critical step in the technical validation of Floodlight technology to measure gait and balance in PwMS, and will also allow the development of new test designs and algorithms.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Lisa Bunn
- Faculty of Health, University of Plymouth, Plymouth, UK
| | | | | | - Jenny Freeman
- Faculty of Health, University of Plymouth, Plymouth, UK
| | - Jeremy Hobart
- Plymouth University Peninsula Schools of Medicine and Dentistry, Plymouth, UK
| | | | | |
Collapse
|
4
|
Das R, Paul S, Mourya GK, Kumar N, Hussain M. Recent Trends and Practices Toward Assessment and Rehabilitation of Neurodegenerative Disorders: Insights From Human Gait. Front Neurosci 2022; 16:859298. [PMID: 35495059 PMCID: PMC9051393 DOI: 10.3389/fnins.2022.859298] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Accepted: 03/01/2022] [Indexed: 12/06/2022] Open
Abstract
The study of human movement and biomechanics forms an integral part of various clinical assessments and provides valuable information toward diagnosing neurodegenerative disorders where the motor symptoms predominate. Conventional gait and postural balance analysis techniques like force platforms, motion cameras, etc., are complex, expensive equipment requiring specialist operators, thereby posing a significant challenge toward translation to the clinics. The current manuscript presents an overview and relevant literature summarizing the umbrella of factors associated with neurodegenerative disorder management: from the pathogenesis and motor symptoms of commonly occurring disorders to current alternate practices toward its quantification and mitigation. This article reviews recent advances in technologies and methodologies for managing important neurodegenerative gait and balance disorders, emphasizing assessment and rehabilitation/assistance. The review predominantly focuses on the application of inertial sensors toward various facets of gait analysis, including event detection, spatiotemporal gait parameter measurement, estimation of joint kinematics, and postural balance analysis. In addition, the use of other sensing principles such as foot-force interaction measurement, electromyography techniques, electrogoniometers, force-myography, ultrasonic, piezoelectric, and microphone sensors has also been explored. The review also examined the commercially available wearable gait analysis systems. Additionally, a summary of recent progress in therapeutic approaches, viz., wearables, virtual reality (VR), and phytochemical compounds, has also been presented, explicitly targeting the neuro-motor and functional impairments associated with these disorders. Efforts toward therapeutic and functional rehabilitation through VR, wearables, and different phytochemical compounds are presented using recent examples of research across the commonly occurring neurodegenerative conditions [viz., Parkinson's disease (PD), Alzheimer's disease (AD), multiple sclerosis, Huntington's disease (HD), and amyotrophic lateral sclerosis (ALS)]. Studies exploring the potential role of Phyto compounds in mitigating commonly associated neurodegenerative pathologies such as mitochondrial dysfunction, α-synuclein accumulation, imbalance of free radicals, etc., are also discussed in breadth. Parameters such as joint angles, plantar pressure, and muscle force can be measured using portable and wearable sensors like accelerometers, gyroscopes, footswitches, force sensors, etc. Kinetic foot insoles and inertial measurement tools are widely explored for studying kinematic and kinetic parameters associated with gait. With advanced correlation algorithms and extensive RCTs, such measurement techniques can be an effective clinical and home-based monitoring and rehabilitation tool for neuro-impaired gait. As evident from the present literature, although the vast majority of works reported are not clinically and extensively validated to derive a firm conclusion about the effectiveness of such techniques, wearable sensors present a promising impact toward dealing with neurodegenerative motor disorders.
Collapse
Affiliation(s)
- Ratan Das
- Department of Biomedical Engineering, North-Eastern Hill University, Shillong, India
| | - Sudip Paul
- Department of Biomedical Engineering, North-Eastern Hill University, Shillong, India
| | - Gajendra Kumar Mourya
- Department of Biomedical Engineering, North-Eastern Hill University, Shillong, India
| | - Neelesh Kumar
- Biomedical Applications Unit, Central Scientific Instruments Organisation, Chandigarh, India
| | - Masaraf Hussain
- Department of Neurology, North Eastern Indira Gandhi Regional Institute of Health and Medical Sciences, Shillong, India
| |
Collapse
|
5
|
A Perspective Roadmap for IoMT-Based Early Detection and Care of the Neural Disorder, Dementia. JOURNAL OF HEALTHCARE ENGINEERING 2021; 2021:6712424. [PMID: 34880977 PMCID: PMC8648455 DOI: 10.1155/2021/6712424] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Accepted: 11/12/2021] [Indexed: 12/05/2022]
Abstract
The Internet of Medical Things (IoMT) has emerged as one of the most important key applications of IoT. IoMT makes the diagnosis and care more convenient and reliable with proven results. The paper presents the technology, open issues, and challenges of IoMT-based systems. It explores the various types of sensors and smart equipment based on IoMT and used for diagnosis and patient care. A comprehensive survey of early detection and postdetection care of the neural disorder dementia is conducted. The paper also presents a postdiagnosis dementia care model named “Demencare.” This model incorporates eight sensors capable of tracking the daily routine of dementia patient. The patients can be monitored locally by an edge computing device kept at their premises. The medical experts may also monitor the patients' status for any deviation from normal behavior. IoMT enables better postdiagnosis care for neural disorders, like dementia and Alzheimer's. The patient's behavior and vital parameters are always available despite the remote location of the patients. The data of the patients may be classified, and new insights may be obtained to tackle patients in a better manner.
Collapse
|
6
|
Effectiveness of an individually tailored home-based exercise rogramme for pre-frail older adults, driven by a tablet application and mobility monitoring: a pilot study. Eur Rev Aging Phys Act 2021; 18:10. [PMID: 34154524 PMCID: PMC8215778 DOI: 10.1186/s11556-021-00264-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2021] [Accepted: 05/20/2021] [Indexed: 11/11/2022] Open
Abstract
Objectives To gain first insight into the effectiveness of a home-based exercise programme for pre-frail older adults with independent use of novel ICT technology. Methods A pilot study. Forty pre-frail older adults joined a six-month home-based exercise programme using a tablet PC for exercise administration and feedback, and a necklace-worn motion sensor for daily physical activity registration. Participants received weekly telephone supervision during the first 3 months and exercised independently without supervision from a coach during the last 3 months. Functional performance and daily physical activity were assessed at baseline, after three and 6 months. Results Twenty-one participants completed the programme. Overall, functional performance showed positive results varying from (very) small to large effects (Cohen’s d 0.04–0.81), mainly during the supervised part of the intervention. Regarding daily physical activity, a slight improvement with (very) small effects (Cohen’s d 0.07–0.38), was observed for both self-reported and objectively measured physical activity during the supervised period. However, during the unsupervised period this pattern only continued for self-reported physical activity. Conclusion This pilot study showed positive results varying from (very) small to large effects in levels and maintenance of functional performance and daily physical activity, especially during the supervised first 3 months. Remote supervision seems to importantly affect effectiveness of a home-based exercise programme. Effectiveness of the programme and the exact contribution of its components should be further quantified in a randomized controlled trial. Practice implications Home-based exercising using novel technology may be promising for functional performance and physical activity improvement in (pre-frail) older adults. Trial registration Netherlands Trial Register (NTR); trial number NL4049. The study was prospectively registered (registration date 14/11/2013). Supplementary Information The online version contains supplementary material available at 10.1186/s11556-021-00264-y.
Collapse
|
7
|
Hou C, Zhang F, Chen C, Zhang Y, Wu R, Ma L, Lin C, Guo W, Liu XY. Wearable hydration and pH sensor based on protein film for healthcare monitoring. CHEMICAL PAPERS 2021. [DOI: 10.1007/s11696-021-01627-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
|
8
|
Musical improvisation enhances interpersonal coordination in subsequent conversation: Motor and speech evidence. PLoS One 2021; 16:e0250166. [PMID: 33857238 PMCID: PMC8049323 DOI: 10.1371/journal.pone.0250166] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2020] [Accepted: 03/31/2021] [Indexed: 11/19/2022] Open
Abstract
This study explored the effects of musical improvisation between dyads of same-sex strangers on subsequent behavioural alignment. Participants-all non-musicians-conversed before and after either improvising music together (Musical Improvisation-MI-group) or doing a motoric non-rhythmic cooperative task (building a tower together using wooden blocks; the Hands-Busy-HB-group). Conversations were free, but initially guided by an adaptation of the Fast Friends Questionnaire for inducing talk among students who are strangers and meeting for the first time. Throughout, participants' motion was recorded with an optical motion-capture system (Mocap) and analysed in terms of speed cross-correlations. Their conversations were also recorded on separate channels using headset microphones and were analysed in terms of the periodicity displayed by rhythmic peaks in the turn transitions across question and answer pairs (Q+A pairs). Compared with their first conversations, the MI group in the second conversations showed: (a) a very rapid, partially simultaneous anatomical coordination between 0 and 0.4 s; (b) delayed mirror motoric coordination between 0.8 and 1.5 s; and (c) a higher proportion of Periodic Q+A pairs. In contrast, the HB group's motoric coordination changed slightly in timing but not in degree of coordination between the first and second conversations, and there was no significant change in the proportion of periodic Q+A pairs they produced. These results show a convergent effect of prior musical interaction on joint body movement and use of shared periodicity across speech turn-transitions in conversations, suggesting that interaction in music and speech may be mediated by common processes.
Collapse
|
9
|
Lee G, Choi W, Jo H, Park W, Kim J. Analysis of motor control strategy for frontal and sagittal planes of circular tracking movements using visual feedback noise from velocity change and depth information. PLoS One 2020; 15:e0241138. [PMID: 33175910 PMCID: PMC7657550 DOI: 10.1371/journal.pone.0241138] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2020] [Accepted: 10/08/2020] [Indexed: 11/19/2022] Open
Abstract
We aim to investigate a control strategy for the circular tracking movement in a three-dimensional (3D) space based on the accuracy of the visual information. After setting the circular orbits for the frontal and sagittal planes in the 3D virtual space, the subjects track a target moving at a constant velocity. The analysis is applied to two parameters of the polar coordinates, namely, ΔR (the difference in the distance from the center of a circular orbit) and Δω (the difference in the angular velocity). The movement in the sagittal plane provides different depth information depending on the position of the target in orbit, unlike the task of the frontal plane. Therefore, the circular orbit is divided into four quadrants for a statistical analysis of ΔR. In the sagittal plane, the error was two to three times larger in quadrants 1 and 4 than in quadrants 2 and 3 close to the subject. Here, Δω is estimated using a frequency analysis; the lower the accuracy of the visual information, the greater the periodicity. When comparing two different planes, the periodicity in the sagittal plane was approximately 1.7 to 2 times larger than that of the frontal plane. In addition, the average angular velocity of the target and tracer was within 0.6% during a single cycle. We found that if the amount of visual information is reduced, an optimal feedback control strategy can be used to reduce the positional error within a specific area.
Collapse
Affiliation(s)
- Geonhui Lee
- Department of Mechanical and Control Engineering, Handong Global University, Pohang, Republic of Korea
| | - Woong Choi
- Department of Information and Computer Engineering, National Institute of Technology, Gunma College, Maebashi, Japan
- * E-mail: (WC); (JK)
| | - Hanjin Jo
- Department of Mechanical and Control Engineering, Handong Global University, Pohang, Republic of Korea
| | - Wookhyun Park
- Department of Mechanical and Control Engineering, Handong Global University, Pohang, Republic of Korea
| | - Jaehyo Kim
- Department of Mechanical and Control Engineering, Handong Global University, Pohang, Republic of Korea
- * E-mail: (WC); (JK)
| |
Collapse
|
10
|
Graña M, Aguilar-Moreno M, De Lope Asiain J, Araquistain IB, Garmendia X. Improved Activity Recognition Combining Inertial Motion Sensors and Electroencephalogram Signals. Int J Neural Syst 2020; 30:2050053. [DOI: 10.1142/s0129065720500537] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Human activity recognition and neural activity analysis are the basis for human computational neureoethology research dealing with the simultaneous analysis of behavioral ethogram descriptions and neural activity measurements. Wireless electroencephalography (EEG) and wireless inertial measurement units (IMU) allow the realization of experimental data recording with improved ecological validity where the subjects can be carrying out natural activities while data recording is minimally invasive. Specifically, we aim to show that EEG and IMU data fusion allows improved human activity recognition in a natural setting. We have defined an experimental protocol composed of natural sitting, standing and walking activities, and we have recruited subjects in two sites: in-house ([Formula: see text]) and out-house ([Formula: see text]) populations with different demographics. Experimental protocol data capture was carried out with validated commercial systems. Classifier model training and validation were carried out with scikit-learn open source machine learning python package. EEG features consist of the amplitude of the standard EEG frequency bands. Inertial features were the instantaneous position of the body tracked points after a moving average smoothing to remove noise. We carry out three validation processes: a 10-fold cross-validation process per experimental protocol repetition, (b) the inference of the ethograms, and (c) the transfer learning from each experimental protocol repetition to the remaining repetitions. The in-house accuracy results were lower and much more variable than the out-house sessions results. In general, random forest was the best performing classifier model. Best cross-validation results, ethogram accuracy, and transfer learning were achieved from the fusion of EEG and IMUs data. Transfer learning behaved poorly compared to classification on the same protocol repetition, but it has accuracy still greater than 0.75 on average for the out-house data sessions. Transfer leaning accuracy among repetitions of the same subject was above 0.88 on average. Ethogram prediction accuracy was above 0.96 on average. Therefore, we conclude that wireless EEG and IMUs allow for the definition of natural experimental designs with high ecological validity toward human computational neuroethology research. The fusion of both EEG and IMUs signals improves activity and ethogram recognition.
Collapse
Affiliation(s)
- Manuel Graña
- Computational Intelligence Group, University of the Basque Country (UPV/EHU), San Sebastian, Spain
| | - Marina Aguilar-Moreno
- Computational Intelligence Group, University of the Basque Country (UPV/EHU), San Sebastian, Spain
| | - Javier De Lope Asiain
- Department of Artificial Intelligence, Universidad Politécnica de Madrid (UPM), Madrid, Spain
| | | | - Xavier Garmendia
- Computational Intelligence Group, University of the Basque Country (UPV/EHU), San Sebastian, Spain
| |
Collapse
|
11
|
Cuadros Z, Hurtado E, Cornejo C. Measuring Dynamics of Infant-Adult Synchrony Through Mocap. Front Psychol 2019; 10:2839. [PMID: 31920869 PMCID: PMC6930835 DOI: 10.3389/fpsyg.2019.02839] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2019] [Accepted: 12/02/2019] [Indexed: 11/13/2022] Open
Abstract
The temporal dynamics of parent-infant synchrony have been well documented. In recent years, the introduction of more accurate technologies for tracking movements has allowed the distinction of different morphological patterns of dyadic coordination. However, the potential of these technologies to explore infant-adult synchrony has not yet been explored. In the present study, we examined the temporal, spatial, and morphological synchrony patterns of infant-unknown adult pairs participating in a storytime session by a motion capture system (mocap). We find low but significant correlation levels of body synchrony between infants and unknown adults. This synchronized coactivity adopted two differentiated forms: mirror-like and anatomical. While the infants' movements mirrored those of the adults with a lag (0.9 s), the adults' reactions to the infants were anatomical with delay (0.4 s). This evidence could contribute novel insights to rethink synchrony and its measurement.
Collapse
Affiliation(s)
| | | | - Carlos Cornejo
- Laboratorio de Lenguaje Interacción y Fenomenología, Escuela de Psicología, Pontificia Universidad Católica de Chile, Santiago, Chile
| |
Collapse
|
12
|
|
13
|
Development of a gold-standard method for the identification of sedentary, light and moderate physical activities in older adults: Definitions for video annotation. J Sci Med Sport 2018; 22:557-561. [PMID: 30509863 DOI: 10.1016/j.jsams.2018.11.011] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2018] [Revised: 09/24/2018] [Accepted: 11/06/2018] [Indexed: 11/24/2022]
Abstract
OBJECTIVES The development of a reliable method for the identification of sedentary, light and moderate physical activities in older adults. The method consists of a validated set of definitions for the identification of the initiation and termination of physical activities performed by older adult participants, video recorded during free-living and a laboratory setting. DESIGN Inter-rater reliability assessment in a fully crossed design. METHODS An iterative consensus process was used to define the initiation and termination of common activities of daily living. These definitions were then tested using videos recorded in two scenarios (1) by 9 raters who annotated a video recording, of a free-living protocol in a home environment, recorded in a first person view, using a body-worn camera and (2) by 7 raters who annotated a video recording, of older adults performing a semi-structured protocol in a living-lab environment, recorded in a third person view, using wall mounted cameras. RESULTS Inter-rater reliability was excellent for all items, with Krippendorff's alpha and Fleiss' kappa all above 0.84 and a percentage of agreement above 88%. All ICC(C,1) inter-rater values for the activity quantity and duration were all above 0.9. CONCLUSIONS This set of physical activity initiation and termination definitions offers independent researchers a gold standard method to allow for the consistent annotation of high-frequency video footage (25fps), in both a free-living and laboratory setting. When synchronised with body-worn or ambient sensors, this annotation will allow for the development and validation of physical activity classification systems to a higher resolution than before.
Collapse
|
14
|
Fall CL, Quevillon F, Blouin M, Latour S, Campeau-Lecours A, Gosselin C, Gosselin B. A Multimodal Adaptive Wireless Control Interface for People With Upper-Body Disabilities. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2018; 12:564-575. [PMID: 29877820 DOI: 10.1109/tbcas.2018.2810256] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
This paper describes a multimodal body-machine interface (BoMI) to help individuals with upper-limb disabilities using advanced assistive technologies, such as robotic arms. The proposed system uses a wearable and wireless body sensor network (WBSN) supporting up to six sensor nodes to measure the natural upper-body gesture of the users and translate it into control commands. Natural gesture of the head and upper-body parts, as well as muscular activity, are measured using inertial measurement units (IMUs) and surface electromyography (sEMG) using custom-designed multimodal wireless sensor nodes. An IMU sensing node is attached to a headset worn by the user. It has a size of 2.9 cm 2.9 cm, a maximum power consumption of 31 mW, and provides angular precision of 1. Multimodal patch sensor nodes, including both IMU and sEMG sensing modalities are placed over the user able-body parts to measure the motion and muscular activity. These nodes have a size of 2.5 cm 4.0 cm and a maximum power consumption of 11 mW. The proposed BoMI runs on a Raspberry Pi. It can adapt to several types of users through different control scenarios using the head and shoulder motion, as well as muscular activity, and provides a power autonomy of up to 24 h. JACO, a 6-DoF assistive robotic arm, is used as a testbed to evaluate the performance of the proposed BoMI. Ten able-bodied subjects performed ADLs while operating the AT device, using the Test d'Évaluation des Membres Supérieurs de Personnes Âgées to evaluate and compare the proposed BoMI with the conventional joystick controller. It is shown that the users can perform all tasks with the proposed BoMI, almost as fast as with the joystick controller, with only 30% time overhead on average, while being potentially more accessible to the upper-body disabled who cannot use the conventional joystick controller. Tests show that control performance with the proposed BoMI improved by up to 17% on average, after three trials.
Collapse
|
15
|
A Review of Medication Adherence Monitoring Technologies. APPLIED SYSTEM INNOVATION 2018. [DOI: 10.3390/asi1020014] [Citation(s) in RCA: 61] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
16
|
Takahashi D, Hara K, Okano T, Suzuki H. A fluidics-based impact sensor. PLoS One 2018; 13:e0195741. [PMID: 29634750 PMCID: PMC5892937 DOI: 10.1371/journal.pone.0195741] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2017] [Accepted: 03/28/2018] [Indexed: 11/23/2022] Open
Abstract
Microelectromechanical systems (MEMS)-based high-performance accelerometers are ubiquitously used in various electronic devices. However, there is an existing need to detect physical impacts using low-cost devices with no electronic circuits or a battery. We designed and fabricated an impact sensor prototype using a commercial stereolithography apparatus that only consists of a plastic housing and working fluids. The sensor device responds to the instantaneous acceleration (impact) by deformation and pinch off of a water droplet that is suspended in oil in a sensor cavity. We tested the various geometrical and physical parameters of the impact sensor to identify their relations to threshold acceleration values. We show that the state diagram that is plotted against the dimensionless Archimedes and Bond numbers adequately describes the response of the proposed sensor.
Collapse
Affiliation(s)
- Daigo Takahashi
- Faculty of Science and Engineering, Chuo University, Tokyo, Japan
| | - Keisuke Hara
- Faculty of Science and Engineering, Chuo University, Tokyo, Japan
| | - Taiji Okano
- Faculty of Science and Engineering, Chuo University, Tokyo, Japan
| | - Hiroaki Suzuki
- Faculty of Science and Engineering, Chuo University, Tokyo, Japan
- * E-mail:
| |
Collapse
|
17
|
Fox JL, Scanlan AT, Stanton R. A Review of Player Monitoring Approaches in Basketball: Current Trends and Future Directions. J Strength Cond Res 2017; 31:2021-2029. [PMID: 28445227 DOI: 10.1519/jsc.0000000000001964] [Citation(s) in RCA: 91] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Fox, JL, Scanlan, AT, and Stanton, R. A review of player monitoring approaches in basketball: current trends and future directions. J Strength Cond Res 31(7): 2021-2029, 2017-Effective monitoring of players in team sports such as basketball requires an understanding of the external demands and internal responses, as they relate to training phases and competition. Monitoring of external demands and internal responses allows coaching staff to determine the dose-response associated with the imposed training load (TL), and subsequently, if players are adequately prepared for competition. This review discusses measures reported in the literature for monitoring the external demands and internal responses of basketball players during training and competition. The external demands of training and competition were primarily monitored using time-motion analysis, with limited use of microtechnology being reported. Internal responses during training were typically measured using hematological markers, heart rate, various TL models, and perceptual responses such as rating of perceived exertion (RPE). Heart rate was the most commonly reported indicator of internal responses during competition with limited reporting of hematological markers or RPE. These findings show a large discrepancy between the reporting of external and internal measures and training and competition demands. Microsensors, however, may be a practical and convenient method of player monitoring in basketball to overcome the limitations associated with current approaches while allowing for external demands and internal responses to be recorded simultaneously. The triaxial accelerometers of microsensors seem well suited for basketball and warrant validation to definitively determine their place in the monitoring of basketball players. Coaching staff should make use of this technology by tracking individual player responses across the annual plan and using real-time monitoring to minimize factors such as fatigue and injury risk.
Collapse
Affiliation(s)
- Jordan L Fox
- 1School of Health, Medical, and Applied Sciences, Central Queensland University, Rockhampton, Australia; and 2Human Exercise and Training Laboratory, Central Queensland University, Rockhampton, Australia
| | | | | |
Collapse
|
18
|
Penteridis L, D'Onofrio G, Sancarlo D, Giuliani F, Ricciardi F, Cavallo F, Greco A, Trochidis I, Gkiokas A. Robotic and Sensor Technologies for Mobility in Older People. Rejuvenation Res 2017; 20:401-410. [DOI: 10.1089/rej.2017.1965] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Affiliation(s)
- Lazaros Penteridis
- Ortelio Ltd., Coventry University Technology Park, Puma Way, Coventry, United Kingdom
| | - Grazia D'Onofrio
- Complex Unit of Geriatrics, Department of Medical Sciences, IRCCS “Casa Sollievo della Sofferenza,” San Giovanni Rotondo, Foggia, Italy
- The BioRobotics Institute, Scuola Superiore Sant'Anna, Pontedera, Italy
| | - Daniele Sancarlo
- Complex Unit of Geriatrics, Department of Medical Sciences, IRCCS “Casa Sollievo della Sofferenza,” San Giovanni Rotondo, Foggia, Italy
| | - Francesco Giuliani
- ICT, Innovation & Research Unit, IRCCS “Casa Sollievo della Sofferenza,” San Giovanni Rotondo, Foggia, Italy
| | - Francesco Ricciardi
- ICT, Innovation & Research Unit, IRCCS “Casa Sollievo della Sofferenza,” San Giovanni Rotondo, Foggia, Italy
| | - Filippo Cavallo
- The BioRobotics Institute, Scuola Superiore Sant'Anna, Pontedera, Italy
| | - Antonio Greco
- Complex Unit of Geriatrics, Department of Medical Sciences, IRCCS “Casa Sollievo della Sofferenza,” San Giovanni Rotondo, Foggia, Italy
| | - Ilias Trochidis
- Ortelio Ltd., Coventry University Technology Park, Puma Way, Coventry, United Kingdom
| | - Alexander Gkiokas
- Ortelio Ltd., Coventry University Technology Park, Puma Way, Coventry, United Kingdom
| |
Collapse
|
19
|
|
20
|
An Explicit Method for Analysis of Three-Dimensional Linear and Angular Velocity of a Joint, with Specific Application to the Knee Joint. J Med Biol Eng 2017. [DOI: 10.1007/s40846-017-0298-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
21
|
Actogram analysis of free-flying migratory birds: new perspectives based on acceleration logging. J Comp Physiol A Neuroethol Sens Neural Behav Physiol 2017; 203:543-564. [PMID: 28343237 PMCID: PMC5522517 DOI: 10.1007/s00359-017-1165-9] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2016] [Revised: 03/06/2017] [Accepted: 03/07/2017] [Indexed: 11/24/2022]
Abstract
The use of accelerometers has become an important part of biologging techniques for large-sized birds with accelerometer data providing information about flight mode, wing-beat pattern, behaviour and energy expenditure. Such data show that birds using much energy-saving soaring/gliding flight like frigatebirds and swifts can stay airborne without landing for several months. Successful accelerometer studies have recently been conducted also for free-flying small songbirds during their entire annual cycle. Here we review the principles and possibilities for accelerometer studies in bird migration. We use the first annual actograms (for red-backed shrike Lanius collurio) to explore new analyses and insights that become possible with accelerometer data. Actogram data allow precise estimates of numbers of flights, flight durations as well as departure/landing times during the annual cycle. Annual and diurnal rhythms of migratory flights, as well as prolonged nocturnal flights across desert barriers are illustrated. The shifting balance between flight, rest and different intensities of activity throughout the year as revealed by actogram data can be used to analyse exertion levels during different phases of the life cycle. Accelerometer recording of the annual activity patterns of individual birds will open up a new dimension in bird migration research.
Collapse
|
22
|
A Physical Activity Reference Data-Set Recorded from Older Adults Using Body-Worn Inertial Sensors and Video Technology-The ADAPT Study Data-Set. SENSORS 2017; 17:s17030559. [PMID: 28287449 PMCID: PMC5375845 DOI: 10.3390/s17030559] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/27/2017] [Revised: 02/24/2017] [Accepted: 03/08/2017] [Indexed: 01/23/2023]
Abstract
Physical activity monitoring algorithms are often developed using conditions that do not represent real-life activities, not developed using the target population, or not labelled to a high enough resolution to capture the true detail of human movement. We have designed a semi-structured supervised laboratory-based activity protocol and an unsupervised free-living activity protocol and recorded 20 older adults performing both protocols while wearing up to 12 body-worn sensors. Subjects’ movements were recorded using synchronised cameras (≥25 fps), both deployed in a laboratory environment to capture the in-lab portion of the protocol and a body-worn camera for out-of-lab activities. Video labelling of the subjects’ movements was performed by five raters using 11 different category labels. The overall level of agreement was high (percentage of agreement >90.05%, and Cohen’s Kappa, corrected kappa, Krippendorff’s alpha and Fleiss’ kappa >0.86). A total of 43.92 h of activities were recorded, including 9.52 h of in-lab and 34.41 h of out-of-lab activities. A total of 88.37% and 152.01% of planned transitions were recorded during the in-lab and out-of-lab scenarios, respectively. This study has produced the most detailed dataset to date of inertial sensor data, synchronised with high frame-rate (≥25 fps) video labelled data recorded in a free-living environment from older adults living independently. This dataset is suitable for validation of existing activity classification systems and development of new activity classification algorithms.
Collapse
|
23
|
Stanton R, Guertler D, Duncan MJ, Vandelanotte C. Agreement between activPAL3c accelerometers placed at different thigh positions. Gait Posture 2016; 48:230-236. [PMID: 27367936 DOI: 10.1016/j.gaitpost.2016.06.013] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/17/2015] [Revised: 06/02/2016] [Accepted: 06/10/2016] [Indexed: 02/02/2023]
Abstract
ActivPAL3c triaxial accelerometers are increasingly used to assess physical activity and sedentary behaviours. However, little is known how attachment site (left vs. right or upper vs. lower thigh) affects activPAL3c accelerometer outcomes. Twenty-eight adults wore four activPAL3c accelerometers attached 2cm above and below the midpoint of the left and right thigh during five minutes of laboratory-based walking at a self-selected pace, treadmill walking at 0.89 and 1.56m/s, and treadmill running at 2.22m/s, and during approximately seven hours of free-living conditions. One-way ANOVA revealed no statistically significant differences in accelerometer output between ActivPAL3c accelerometers at these locations during both laboratory-based, and free-living conditions. Intraclass correlation coefficients showed a high level of agreement between activPAL3c accelerometers during laboratory and free living activities (ICC(2,1) 0.76-1.00). The attachment sites used in this study do not appear to significantly influence outcomes for step count, sitting or walking time, or number of postural transitions from triaxial activPAL3c accelerometers during laboratory-based walking or free-living conditions. Therefore if necessary, to enhance participant compliance during monitoring periods, these sites could be used interchangeably. Studies of longer duration incorporating additional laboratory and recreational activities are needed to confirm these findings.
Collapse
Affiliation(s)
- Robert Stanton
- School of Medical and Applied Sciences, Central Queensland University, Bruce Highway, Rockhampton QLD 4702, Australia.
| | - Diana Guertler
- Centre for Physical Activity Studies, School of Human, Health and Social Sciences, Central Queensland University, Bruce Highway, Rockhampton QLD 4702, Australia; Institute for Social Medicine and Prevention, Faculty of Medicine, University of Greifswald, 17475 Greifswald, Germany
| | - Mitch J Duncan
- Centre for Physical Activity Studies, School of Human, Health and Social Sciences, Central Queensland University, Bruce Highway, Rockhampton QLD 4702, Australia; School of Medicine & Public Health, Priority Research Centre for Physical Activity and Nutrition, Faculty of Health and Medicine, The University of Newcastle, University Drive, Callaghan NSW 2308, Australia
| | - Corneel Vandelanotte
- Centre for Physical Activity Studies, School of Human, Health and Social Sciences, Central Queensland University, Bruce Highway, Rockhampton QLD 4702, Australia
| |
Collapse
|
24
|
Validation and User Evaluation of a Sensor-Based Method for Detecting Mobility-Related Activities in Older Adults. PLoS One 2015; 10:e0137668. [PMID: 26361009 PMCID: PMC4567066 DOI: 10.1371/journal.pone.0137668] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2015] [Accepted: 08/20/2015] [Indexed: 11/19/2022] Open
Abstract
Regular physical activity is essential for older adults to stay healthy and independent. However, daily physical activity is generally low among older adults and mainly consists of activities such as standing and shuffling around indoors. Accurate measurement of this low-energy expenditure daily physical activity is crucial for stimulation of activity. The objective of this study was to assess the validity of a necklace-worn sensor-based method for detecting time-on-legs and daily life mobility related postures in older adults. In addition user opinion about the practical use of the sensor was evaluated. Twenty frail and non-frail older adults performed a standardized and free movement protocol in their own home. Results of the sensor-based method were compared to video observation. Sensitivity, specificity and overall agreement of sensor outcomes compared to video observation were calculated. Mobility was assessed based on time-on-legs. Further assessment included the categories standing, sitting, walking and lying. Time-on-legs based sensitivity, specificity and percentage agreement were good to excellent and comparable to laboratory outcomes in other studies. Category-based sensitivity, specificity and overall agreement were moderate to excellent. The necklace-worn sensor is considered an acceptable valid instrument for assessing home-based physical activity based upon time-on-legs in frail and non-frail older adults, but category-based assessment of gait and postures could be further developed.
Collapse
|
25
|
Jarning JM, Mok KM, Hansen BH, Bahr R. Application of a tri-axial accelerometer to estimate jump frequency in volleyball. Sports Biomech 2015; 14:95-105. [PMID: 25902964 DOI: 10.1080/14763141.2015.1027950] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
Patellar tendinopathy is prevalent among athletes, and most likely associated with a high jumping load. If methods for estimating jump frequency were available, this could potentially assist in understanding and preventing this condition. The objective of this study was to explore the possibility of using peak vertical acceleration (PVA) or peak resultant acceleration (PRA) measured by an accelerometer to estimate jump frequency. Twelve male elite volleyball players (22.5 ± 1.6 yrs) performed a training protocol consisting of seven typical motion patterns, including jumping and non-jumping movements. Accelerometer data from the trial were obtained using a tri-axial accelerometer. In addition, we collected video data from the trial. Jump-float serving and spike jumping could not be distinguished from non-jumping movements using differences in PVA or PRA. Furthermore, there were substantial inter-participant differences in both the PVA and the PRA within and across movement types (p < 0.05). These findings suggest that neither PVA nor PRA measured by a tri-axial accelerometer is an applicable method for estimating jump frequency in volleyball. A method for acquiring real-time estimates of jump frequency remains to be verified. However, there are several alternative approaches, and further investigations are needed.
Collapse
Affiliation(s)
- Jon M Jarning
- a Faculty of Medicine and Dentistry , University of Bergen , Bergen , Norway
| | | | | | | |
Collapse
|
26
|
Improving the precision and speed of Euler angles computation from low-cost rotation sensor data. SENSORS 2015; 15:7016-39. [PMID: 25806874 PMCID: PMC4435132 DOI: 10.3390/s150307016] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/05/2015] [Revised: 02/19/2015] [Accepted: 03/17/2015] [Indexed: 11/22/2022]
Abstract
This article compares three different algorithms used to compute Euler angles from data obtained by the angular rate sensor (e.g., MEMS gyroscope)—the algorithms based on a rotational matrix, on transforming angular velocity to time derivations of the Euler angles and on unit quaternion expressing rotation. Algorithms are compared by their computational efficiency and accuracy of Euler angles estimation. If attitude of the object is computed only from data obtained by the gyroscope, the quaternion-based algorithm seems to be most suitable (having similar accuracy as the matrix-based algorithm, but taking approx. 30% less clock cycles on the 8-bit microcomputer). Integration of the Euler angles’ time derivations has a singularity, therefore is not accurate at full range of object’s attitude. Since the error in every real gyroscope system tends to increase with time due to its offset and thermal drift, we also propose some measures based on compensation by additional sensors (a magnetic compass and accelerometer). Vector data of mentioned secondary sensors has to be transformed into the inertial frame of reference. While transformation of the vector by the matrix is slightly faster than doing the same by quaternion, the compensated sensor system utilizing a matrix-based algorithm can be approximately 10% faster than the system utilizing quaternions (depending on implementation and hardware).
Collapse
|
27
|
Eckardt F, Münz A, Witte K. Application of a Full Body Inertial Measurement System in Dressage Riding. J Equine Vet Sci 2014. [DOI: 10.1016/j.jevs.2014.09.009] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
28
|
Andreou CM, Pahitas Y, Georgiou J. Bio-inspired micro-fluidic angular-rate sensor for vestibular prostheses. SENSORS 2014; 14:13173-85. [PMID: 25054631 PMCID: PMC4168436 DOI: 10.3390/s140713173] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/16/2014] [Revised: 07/01/2014] [Accepted: 07/09/2014] [Indexed: 11/16/2022]
Abstract
This paper presents an alternative approach for angular-rate sensing based on the way that the natural vestibular semicircular canals operate, whereby the inertial mass of a fluid is used to deform a sensing structure upon rotation. The presented gyro has been fabricated in a commercially available MEMS process, which allows for microfluidic channels to be implemented in etched glass layers, which sandwich a bulk-micromachined silicon substrate, containing the sensing structures. Measured results obtained from a proof-of-concept device indicate an angular rate sensitivity of less than 1 °/s, which is similar to that of the natural vestibular system. By avoiding the use of a continually-excited vibrating mass, as is practiced in today's state-of-the-art gyroscopes, an ultra-low power consumption of 300 μW is obtained, thus making it suitable for implantation.
Collapse
Affiliation(s)
- Charalambos M Andreou
- Department of Electrical and Computer Engineering, University of Cyprus, Nicosia 1678, Cyprus.
| | - Yiannis Pahitas
- Department of Electrical and Computer Engineering, University of Cyprus, Nicosia 1678, Cyprus.
| | - Julius Georgiou
- Department of Electrical and Computer Engineering, University of Cyprus, Nicosia 1678, Cyprus.
| |
Collapse
|
29
|
Gait and foot clearance parameters obtained using shoe-worn inertial sensors in a large-population sample of older adults. SENSORS 2013; 14:443-57. [PMID: 24379049 PMCID: PMC3926567 DOI: 10.3390/s140100443] [Citation(s) in RCA: 89] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/29/2013] [Revised: 12/17/2013] [Accepted: 12/18/2013] [Indexed: 11/16/2022]
Abstract
In order to distinguish dysfunctional gait, clinicians require a measure of reference gait parameters for each population. This study provided normative values for widely used parameters in more than 1,400 able-bodied adults over the age of 65. We also measured the foot clearance parameters (i.e., height of the foot above ground during swing phase) that are crucial to understand the complex relationship between gait and falls as well as obstacle negotiation strategies. We used a shoe-worn inertial sensor on each foot and previously validated algorithms to extract the gait parameters during 20 m walking trials in a corridor at a self-selected pace. We investigated the difference of the gait parameters between male and female participants by considering the effect of age and height factors. Besides; we examined the inter-relation of the clearance parameters with the gait speed. The sample size and breadth of gait parameters provided in this study offer a unique reference resource for the researchers.
Collapse
|
30
|
Stanton R, Vandelanotte C, Duncan MJ. Interdevice baseline signal magnitude variability of the ActivPAL3 activity monitor. Gait Posture 2013; 39:618-20. [PMID: 23859721 DOI: 10.1016/j.gaitpost.2013.06.013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2013] [Revised: 06/09/2013] [Accepted: 06/16/2013] [Indexed: 02/02/2023]
Abstract
The aim of this study was to evaluate the interdevice variability in baseline signal magnitude of the ActivPAL3 (PALTechnologies, Glasgow, UK) activity monitor. Twenty consecutively numbered ActivPAL3 triaxial physical activity monitors were assessed for baseline signal magnitudes oriented in the X (vertical standing), Y (side lying), and Z (lying flat) planes. Data was recorded for 60s in each orientation and the three orthogonal axes were analysed for baseline signal magnitude each orientation. Our batch of devices demonstrated approximately 6.6% difference in raw acceleration calibration values compared to manufacturer specifications. Analysis of interdevice variability revealed three devices which exhibited baseline signal variability greater than 1.96 SD of the group mean. The impact of interdevice variability in baseline signal magnitude on data collection is unknown, however, supports the argument in the literature for the systematic checking of interdevice variability as routine maintenance.
Collapse
Affiliation(s)
- Robert Stanton
- Centre for Mental Health Nursing Innovation, Institute for Health and Social Science Research, Central Queensland University, Bruce Highway, Rockhampton, QLD 4702, Australia.
| | | | | |
Collapse
|
31
|
Guarnieri A, Pirotti F, Vettore A. Low-Cost MEMS sensors and vision system for motion and position estimation of a scooter. SENSORS 2013; 13:1510-22. [PMID: 23348036 PMCID: PMC3649400 DOI: 10.3390/s130201510] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/07/2012] [Revised: 01/18/2013] [Accepted: 01/21/2013] [Indexed: 11/16/2022]
Abstract
The possibility to identify with significant accuracy the position of a vehicle in a mapping reference frame for driving directions and best-route analysis is a topic which is attracting a lot of interest from the research and development sector. To reach the objective of accurate vehicle positioning and integrate response events, it is necessary to estimate position, orientation and velocity of the system with high measurement rates. In this work we test a system which uses low-cost sensors, based on Micro Electro-Mechanical Systems (MEMS) technology, coupled with information derived from a video camera placed on a two-wheel motor vehicle (scooter). In comparison to a four-wheel vehicle; the dynamics of a two-wheel vehicle feature a higher level of complexity given that more degrees of freedom must be taken into account. For example a motorcycle can twist sideways; thus generating a roll angle. A slight pitch angle has to be considered as well; since wheel suspensions have a higher degree of motion compared to four-wheel motor vehicles. In this paper we present a method for the accurate reconstruction of the trajectory of a "Vespa" scooter; which can be used as alternative to the "classical" approach based on GPS/INS sensor integration. Position and orientation of the scooter are obtained by integrating MEMS-based orientation sensor data with digital images through a cascade of a Kalman filter and a Bayesian particle filter.
Collapse
Affiliation(s)
- Alberto Guarnieri
- CIRGEO, Interdepartment Research Center for Geomatics, University of Padova, Padova, Italy.
| | | | | |
Collapse
|
32
|
Human behavior cognition using smartphone sensors. SENSORS 2013; 13:1402-24. [PMID: 23348030 PMCID: PMC3649388 DOI: 10.3390/s130201402] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/28/2012] [Revised: 12/26/2012] [Accepted: 01/15/2013] [Indexed: 01/23/2023]
Abstract
This research focuses on sensing context, modeling human behavior and developing a new architecture for a cognitive phone platform. We combine the latest positioning technologies and phone sensors to capture human movements in natural environments and use the movements to study human behavior. Contexts in this research are abstracted as a Context Pyramid which includes six levels: Raw Sensor Data, Physical Parameter, Features/Patterns, Simple Contextual Descriptors, Activity-Level Descriptors, and Rich Context. To achieve implementation of the Context Pyramid on a cognitive phone, three key technologies are utilized: ubiquitous positioning, motion recognition, and human behavior modeling. Preliminary tests indicate that we have successfully achieved the Activity-Level Descriptors level with our LoMoCo (Location-Motion-Context) model. Location accuracy of the proposed solution is up to 1.9 meters in corridor environments and 3.5 meters in open spaces. Test results also indicate that the motion states are recognized with an accuracy rate up to 92.9% using a Least Square-Support Vector Machine (LS-SVM) classifier.
Collapse
|
33
|
Felisberto F, Costa N, Fdez-Riverola F, Pereira A. Unobstructive Body Area Networks (BAN) for efficient movement monitoring. SENSORS 2012; 12:12473-88. [PMID: 23112726 PMCID: PMC3478853 DOI: 10.3390/s120912473] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/16/2012] [Revised: 09/05/2012] [Accepted: 09/10/2012] [Indexed: 11/21/2022]
Abstract
The technological advances in medical sensors, low-power microelectronics and miniaturization, wireless communications and networks have enabled the appearance of a new generation of wireless sensor networks: the so-called wireless body area networks (WBAN). These networks can be used for continuous monitoring of vital parameters, movement, and the surrounding environment. The data gathered by these networks contributes to improve users' quality of life and allows the creation of a knowledge database by using learning techniques, useful to infer abnormal behaviour. In this paper we present a wireless body area network architecture to recognize human movement, identify human postures and detect harmful activities in order to prevent risk situations. The WBAN was created using tiny, cheap and low-power nodes with inertial and physiological sensors, strategically placed on the human body. Doing so, in an as ubiquitous as possible way, ensures that its impact on the users' daily actions is minimum. The information collected by these sensors is transmitted to a central server capable of analysing and processing their data. The proposed system creates movement profiles based on the data sent by the WBAN's nodes, and is able to detect in real time any abnormal movement and allows for a monitored rehabilitation of the user.
Collapse
Affiliation(s)
- Filipe Felisberto
- Higher Technical School of Computer Engineering, University of Vigo, Polytechnic Building, Campus Universitario As Lagoas s/n, 32004 Ourense, Spain; E-Mail:
- INOV INESC INNOVATION, Institute of New Technologies of Leiria, P-2411-901, Leiria, Portugal; E-Mails: (N.C.); (A.P.)
| | - Nuno Costa
- INOV INESC INNOVATION, Institute of New Technologies of Leiria, P-2411-901, Leiria, Portugal; E-Mails: (N.C.); (A.P.)
- Computer Science and Communications Research Centre, School of Technology and Management, Polytechnic Institute of Leiria, P-2411-901, Leiria, Portugal
| | - Florentino Fdez-Riverola
- Higher Technical School of Computer Engineering, University of Vigo, Polytechnic Building, Campus Universitario As Lagoas s/n, 32004 Ourense, Spain; E-Mail:
- Author to whom correspondence should be addressed; E-Mail: ; Tel.: +34-988-387-015; Fax: +34-988-387-001
| | - António Pereira
- INOV INESC INNOVATION, Institute of New Technologies of Leiria, P-2411-901, Leiria, Portugal; E-Mails: (N.C.); (A.P.)
- Computer Science and Communications Research Centre, School of Technology and Management, Polytechnic Institute of Leiria, P-2411-901, Leiria, Portugal
| |
Collapse
|
34
|
Pei L, Liu J, Guinness R, Chen Y, Kuusniemi H, Chen R. Using LS-SVM based motion recognition for smartphone indoor wireless positioning. SENSORS 2012; 12:6155-75. [PMID: 22778635 PMCID: PMC3386734 DOI: 10.3390/s120506155] [Citation(s) in RCA: 101] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/20/2012] [Revised: 04/17/2012] [Accepted: 04/28/2012] [Indexed: 01/23/2023]
Abstract
The paper presents an indoor navigation solution by combining physical motion recognition with wireless positioning. Twenty-seven simple features are extracted from the built-in accelerometers and magnetometers in a smartphone. Eight common motion states used during indoor navigation are detected by a Least Square-Support Vector Machines (LS-SVM) classification algorithm, e.g., static, standing with hand swinging, normal walking while holding the phone in hand, normal walking with hand swinging, fast walking, U-turning, going up stairs, and going down stairs. The results indicate that the motion states are recognized with an accuracy of up to 95.53% for the test cases employed in this study. A motion recognition assisted wireless positioning approach is applied to determine the position of a mobile user. Field tests show a 1.22 m mean error in “Static Tests” and a 3.53 m in “Stop-Go Tests”.
Collapse
Affiliation(s)
- Ling Pei
- Department of Navigation and Positioning, Finnish Geodetic Institute, FIN-02431 Masala, Finland.
| | | | | | | | | | | |
Collapse
|
35
|
Tao W, Liu T, Zheng R, Feng H. Gait analysis using wearable sensors. SENSORS 2012; 12:2255-83. [PMID: 22438763 PMCID: PMC3304165 DOI: 10.3390/s120202255] [Citation(s) in RCA: 414] [Impact Index Per Article: 34.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/18/2012] [Revised: 02/10/2012] [Accepted: 02/13/2012] [Indexed: 01/17/2023]
Abstract
Gait analysis using wearable sensors is an inexpensive, convenient, and efficient manner of providing useful information for multiple health-related applications. As a clinical tool applied in the rehabilitation and diagnosis of medical conditions and sport activities, gait analysis using wearable sensors shows great prospects. The current paper reviews available wearable sensors and ambulatory gait analysis methods based on the various wearable sensors. After an introduction of the gait phases, the principles and features of wearable sensors used in gait analysis are provided. The gait analysis methods based on wearable sensors is divided into gait kinematics, gait kinetics, and electromyography. Studies on the current methods are reviewed, and applications in sports, rehabilitation, and clinical diagnosis are summarized separately. With the development of sensor technology and the analysis method, gait analysis using wearable sensors is expected to play an increasingly important role in clinical applications.
Collapse
Affiliation(s)
- Weijun Tao
- School of Mechanical Engineering, Nanjing University of Science and Technology, 200 Xiaolingwei Street, Nanjing 210094, China; E-Mails: (W.T.); (H.F.)
| | - Tao Liu
- Department of Intelligent Mechanical Systems Engineering, Kochi University of Technology, 185 MIyanokuchi, Tosayamada-Cho, Kami-City, Kochi 782-8502, Japan
- Author to whom correspondence should be addressed; E-Mail: ; Tel.: +81-887-57-2177; Fax: +81-887-57-2170
| | - Rencheng Zheng
- Nakano Lab, Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8505, Japan; E-Mail:
| | - Hutian Feng
- School of Mechanical Engineering, Nanjing University of Science and Technology, 200 Xiaolingwei Street, Nanjing 210094, China; E-Mails: (W.T.); (H.F.)
| |
Collapse
|
36
|
Hannan MA, Abbas SM, Samad SA, Hussain A. Modulation techniques for biomedical implanted devices and their challenges. SENSORS 2011; 12:297-319. [PMID: 22368470 PMCID: PMC3279214 DOI: 10.3390/s120100297] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/22/2011] [Revised: 12/15/2011] [Accepted: 12/15/2011] [Indexed: 11/16/2022]
Abstract
Implanted medical devices are very important electronic devices because of their usefulness in monitoring and diagnosis, safety and comfort for patients. Since 1950s, remarkable efforts have been undertaken for the development of bio-medical implanted and wireless telemetry bio-devices. Issues such as design of suitable modulation methods, use of power and monitoring devices, transfer energy from external to internal parts with high efficiency and high data rates and low power consumption all play an important role in the development of implantable devices. This paper provides a comprehensive survey on various modulation and demodulation techniques such as amplitude shift keying (ASK), frequency shift keying (FSK) and phase shift keying (PSK) of the existing wireless implanted devices. The details of specifications, including carrier frequency, CMOS size, data rate, power consumption and supply, chip area and application of the various modulation schemes of the implanted devices are investigated and summarized in the tables along with the corresponding key references. Current challenges and problems of the typical modulation applications of these technologies are illustrated with a brief suggestions and discussion for the progress of implanted device research in the future. It is observed that the prime requisites for the good quality of the implanted devices and their reliability are the energy transformation, data rate, CMOS size, power consumption and operation frequency. This review will hopefully lead to increasing efforts towards the development of low powered, high efficient, high data rate and reliable implanted devices.
Collapse
Affiliation(s)
- Mahammad A Hannan
- Department of Electrical, Electronic & Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600 UKM Bangi Selangor, Malaysia.
| | | | | | | |
Collapse
|