1
|
Gowda RB, Sharan P, Saara K, Braim M, Alodhayb AN. An FBG-based optical pressure sensor for the measurement of radial artery pulse pressure. JOURNAL OF BIOPHOTONICS 2024; 17:e202400083. [PMID: 38695386 DOI: 10.1002/jbio.202400083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2024] [Revised: 04/15/2024] [Accepted: 04/17/2024] [Indexed: 07/13/2024]
Abstract
One of the diagnostic tool for clinical evaluation and disease diagnosis is a pulse waveform analysis. High fidelity radial artery pulse waveforms have been investigated in clinical research to compute central aortic pressure, which has been demonstrated to be predictive of cardiovascular diseases. The radial artery must be inspected from several angles in order to obtain the best pulse waveform for estimate and diagnosis. In this study, we present the design and experimental testing of an optical sensor based on Fiber Bragg Gratings (FBG). A 3D printed device along with the FBG is used to measure the radial artery pulses. The proposed sensor is used for the purpose of quantifying the radial artery pulse waveform across major pulse position point. The suggested optical sensing system can measure the pulse signal with good accuracy. The main characteristic parameters of the pulse can then be retrieved from the processed signal for their use in clinical applications. By conducting experiments under the direction of medical experts, the pulse signals are measured. In order to experimentally validate the sensor, we used it to detect the pulse waveforms at Guan position of the wrist's radial artery in accordance with the diagnostic standards. The findings show that combining optical technologies for physiological monitoring and radial artery pulse waveform monitoring using FBG in clinical applications are highly feasible.
Collapse
Affiliation(s)
- Ranjith B Gowda
- Department of Electronics & Communication Engineering, SOE, Dayananda Sagar University, Bangalore, India
- Department of Electronics & Communication Engineering, Government Polytechnic Sorab, Shimoga, India
| | - Preeta Sharan
- Department of Electronics & Communication Engineering, The Oxford College of Engineering, Bangalore, India
| | - Saara K
- Department of Electronics & Communication Engineering, SOE, Dayananda Sagar University, Bangalore, India
| | - Mona Braim
- Department of Physics and Astronomy, College of Science, King Saud University, Riyadh, Saudi Arabia
| | - Abdullah N Alodhayb
- Department of Physics and Astronomy, College of Science, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
2
|
Xu J, Pan J, Cui T, Zhang S, Yang Y, Ren TL. Recent Progress of Tactile and Force Sensors for Human-Machine Interaction. SENSORS (BASEL, SWITZERLAND) 2023; 23:1868. [PMID: 36850470 PMCID: PMC9961639 DOI: 10.3390/s23041868] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/29/2022] [Revised: 01/23/2023] [Accepted: 02/01/2023] [Indexed: 06/18/2023]
Abstract
Human-Machine Interface (HMI) plays a key role in the interaction between people and machines, which allows people to easily and intuitively control the machine and immersively experience the virtual world of the meta-universe by virtual reality/augmented reality (VR/AR) technology. Currently, wearable skin-integrated tactile and force sensors are widely used in immersive human-machine interactions due to their ultra-thin, ultra-soft, conformal characteristics. In this paper, the recent progress of tactile and force sensors used in HMI are reviewed, including piezoresistive, capacitive, piezoelectric, triboelectric, and other sensors. Then, this paper discusses how to improve the performance of tactile and force sensors for HMI. Next, this paper summarizes the HMI for dexterous robotic manipulation and VR/AR applications. Finally, this paper summarizes and proposes the future development trend of HMI.
Collapse
Affiliation(s)
- Jiandong Xu
- School of Integrated Circuits and Beijing National Research Center for Information Science and Technology (BNRist), Tsinghua University, Beijing 100084, China
| | - Jiong Pan
- School of Integrated Circuits and Beijing National Research Center for Information Science and Technology (BNRist), Tsinghua University, Beijing 100084, China
| | - Tianrui Cui
- School of Integrated Circuits and Beijing National Research Center for Information Science and Technology (BNRist), Tsinghua University, Beijing 100084, China
| | - Sheng Zhang
- Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China
| | - Yi Yang
- School of Integrated Circuits and Beijing National Research Center for Information Science and Technology (BNRist), Tsinghua University, Beijing 100084, China
| | - Tian-Ling Ren
- School of Integrated Circuits and Beijing National Research Center for Information Science and Technology (BNRist), Tsinghua University, Beijing 100084, China
- Center for Flexible Electronics Technology, Tsinghua University, Beijing 100084, China
| |
Collapse
|
3
|
Shen Z, Liu F, Huang S, Wang H, Yang C, Hang T, Tao J, Xia W, Xie X. Progress of flexible strain sensors for physiological signal monitoring. Biosens Bioelectron 2022; 211:114298. [DOI: 10.1016/j.bios.2022.114298] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Revised: 04/15/2022] [Accepted: 04/19/2022] [Indexed: 11/27/2022]
|
4
|
Kargar SM, Hao G. A Drifter-Based Self-Powered Piezoelectric Sensor for Ocean Wave Measurements. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22135050. [PMID: 35808544 PMCID: PMC9269729 DOI: 10.3390/s22135050] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Revised: 06/30/2022] [Accepted: 07/01/2022] [Indexed: 05/08/2023]
Abstract
Recently, piezoelectric materials have received remarkable attention in marine applications for energy harvesting from the ocean, which is a harsh environment with powerful and impactful waves and currents. However, to the best of the authors' knowledge, although there are various designs of piezoelectric energy harvesters for marine applications, piezoelectric materials have not been employed for sensory and measurement applications in marine environment. In the present research, a drifter-based piezoelectric sensor is proposed to measure ocean waves' height and period. To analyze the motion principle and the working performance of the proposed drifter-based piezoelectric sensor, a dynamic model was developed. The developed dynamic model investigated the system's response to an input of ocean waves and provides design insights into the geometrical and material parameters. Next, finite element analysis (FEA) simulations using the commercial software COMSOL-Multiphysics were carried out with the help of a coupled physics analysis of Solid Mechanics and Electrostatics Modules to achieve the output voltages. An experimental prototype was fabricated and tested to validate the results of the dynamic model and the FEA simulation. A slider-crank mechanism was used to mimic ocean waves throughout the experiment, and the results showed a close match between the proposed dynamic modeling, FEA simulations, and experimental testing. In the end, a short discussion is devoted to interpreting the output results, comparing the results of the simulations with those of the experimental testing, sensor's resolution, and the self-powering functionality of the proposed drifter-based piezoelectric sensor.
Collapse
|
5
|
Contact Pattern Recognition of a Flexible Tactile Sensor Based on the CNN-LSTM Fusion Algorithm. MICROMACHINES 2022; 13:mi13071053. [PMID: 35888868 PMCID: PMC9317185 DOI: 10.3390/mi13071053] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/04/2022] [Revised: 06/22/2022] [Accepted: 06/28/2022] [Indexed: 11/17/2022]
Abstract
Recognizing different contact patterns imposed on tactile sensors plays a very important role in human–machine interaction. In this paper, a flexible tactile sensor with great dynamic response characteristics is designed and manufactured based on polyvinylidene fluoride (PVDF) material. Four contact patterns (stroking, patting, kneading, and scratching) are applied to the tactile sensor, and time sequence data of the four contact patterns are collected. After that, a fusion model based on the convolutional neural network (CNN) and the long-short term memory (LSTM) neural network named CNN-LSTM is constructed. It is used to classify and recognize the four contact patterns loaded on the tactile sensor, and the recognition accuracies of the four patterns are 99.60%, 99.67%, 99.07%, and 99.40%, respectively. At last, a CNN model and a random forest (RF) algorithm model are constructed to recognize the four contact patterns based on the same dataset as those for the CNN-LSTM model. The average accuracies of the four contact patterns based on the CNN-LSTM, the CNN, and the RF algorithm are 99.43%, 96.67%, and 91.39%, respectively. All of the experimental results indicate that the CNN-LSTM constructed in this paper has very efficient performance in recognizing and classifying the contact patterns for the flexible tactile sensor.
Collapse
|
6
|
Saxena P, Shukla P. A comparative analysis of the basic properties and applications of poly (vinylidene fluoride) (PVDF) and poly (methyl methacrylate) (PMMA). Polym Bull (Berl) 2021. [DOI: 10.1007/s00289-021-03790-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
|
7
|
Zhu C, Guo D, Ye D, Jiang S, Huang Y. Flexible PZT-Integrated, Bilateral Sensors via Transfer-Free Laser Lift-Off for Multimodal Measurements. ACS APPLIED MATERIALS & INTERFACES 2020; 12:37354-37362. [PMID: 32814403 DOI: 10.1021/acsami.0c10083] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Fabrication of functional devices that require a high-temperature annealing process on a thin, temperature-sensitive substrate is a long-standing, crucial issue in flexible electronics. Herein, we propose a transfer-free laser lift-off method to directly fabricate lead zirconate titanate (PZT) piezoelectric sensors that commonly undergo a high-temperature annealing (∼650 °C) on ubiquitous flexible substrates, including polyimide (∼300 °C), polyethylene terephthalate (∼120 °C), and polydimethylsiloxane (∼150 °C). The method includes the steps of fabricating sensors, encapsulating a flexible substrate, and peeling off the device by melting the sacrificial PZT layer at the interface with a sapphire glass. The appropriate fluence of laser energy has been figured out to avoid inadequate stripping or damage of the device. In addition, a process window for reliable stripping of the device has been established among the laser fluence and the thickness of the sacrificial layer and the supporting substrate. Furthermore, the capability of the newly proposed technique has been verified and expanded by successfully integrating several sensors that need skillful low-temperature heating treatment on top of a flexible supporting substrate accordingly before stripping. Finally, a PZT-integrated, bilateral multimodal sensor on a PI substrate has been fabricated, and the device demonstrates excellent performance and stability toward perceiving distributed dynamic pressure and temperature stimuli, revealing its high potential for the fabrication of high-performance devices for multimodal sensing applications.
Collapse
Affiliation(s)
- Chen Zhu
- State Key Laboratory of Digital Manufacturing Equipment and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
- Flexible Electronics Research Center, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Dongliang Guo
- State Key Laboratory of Digital Manufacturing Equipment and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
- Flexible Electronics Research Center, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Dong Ye
- State Key Laboratory of Digital Manufacturing Equipment and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
- Flexible Electronics Research Center, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Shan Jiang
- State Key Laboratory of Digital Manufacturing Equipment and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
- Flexible Electronics Research Center, Huazhong University of Science and Technology, Wuhan 430074, China
| | - YongAn Huang
- State Key Laboratory of Digital Manufacturing Equipment and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
- Flexible Electronics Research Center, Huazhong University of Science and Technology, Wuhan 430074, China
| |
Collapse
|
8
|
Integrated Piezoelectric AlN Thin Film with SU-8/PDMS Supporting Layer for Flexible Sensor Array. SENSORS 2020; 20:s20010315. [PMID: 31935913 PMCID: PMC6982933 DOI: 10.3390/s20010315] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/15/2019] [Revised: 12/18/2019] [Accepted: 12/30/2019] [Indexed: 01/27/2023]
Abstract
This research focuses on the development of a flexible tactile sensor array consisting of aluminum nitride (AlN) based on micro-electro-mechanical system (MEMS) technology. A total of 2304 tactile sensors were integrated into a small area of 2.5 × 2.5 cm2. Five hundred nm thick AlN film with strong c-axis texture was sputtered on Cr/Au/Cr (50/50/5 nm) layers as the sacrificial layer coated on a Si wafer. To achieve device flexibility, polydimethylsiloxane (PDMS) polymer and SU-8 photoresist layer were used as the supporting layers after etching away a release layer. Twenty-five mM (3-mercaptopropyl) trimethoxysilane (MPTMS) improves the adhesion between metal and polymers due to formation of a self-assembled monolayer (SAM) on the surface of the top electrode. The flexible tactile sensor has 8 × 8 channels and each channel has 36 sensor elements with nine SU-8 bump blocks. The tactile sensor array was demonstrated to be flexible by bending 90 degrees. The tactile sensor array was demonstrated to show clear spatial resolution through detecting the distinct electrical response of each channel under local mechanical stimulus.
Collapse
|
9
|
Electrical extraction of piezoelectric constants. Heliyon 2018; 4:e00910. [PMID: 30450438 PMCID: PMC6226591 DOI: 10.1016/j.heliyon.2018.e00910] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2018] [Revised: 08/08/2018] [Accepted: 10/29/2018] [Indexed: 11/24/2022] Open
Abstract
The piezoelectric materials are incorporated in smart structure to exhibit specific functionality. The activity of piezoelectric material dimension and electrical properties can be changed with an applied stress. These variations are translated to a change in the capacitance of the structure. This work takes a close outlook on the use of the capacitance-voltage measurements for the extraction of double piezoelectric thin film material deposited at the two faces of a flexible steel sheet. The piezoelectric thin film materials have been deposited using RF sputtering techniques. Gamry analyzer references 3000 was used to collect the capacitance-voltage measurements from both layers. The developed algorithm extracts directly the piezoelectric coefficients knowing the film thickness, the applied voltage, and the capacitance ratio. The capacitance ratio is the ratio between the capacitances of the film when the applied field in antiparallel and parallel to the polling field direction, respectively. The method has been calibrated using a piezoelectric bulk ceramic and validated by comparing the result with the reported values in the literature. The extracted values using the current approach match well the values extracted by other existing methods.
Collapse
|
10
|
Debonding Detection in Hidden Frame Supported Glass Curtain Walls Using the Nonlinear Ultrasonic Modulation Method with Piezoceramic Transducers. SENSORS 2018; 18:s18072094. [PMID: 29966292 PMCID: PMC6068805 DOI: 10.3390/s18072094] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/18/2018] [Revised: 06/26/2018] [Accepted: 06/26/2018] [Indexed: 11/17/2022]
Abstract
Debonding defects are common and they are the main reason for the failure of hidden frame supported glass curtain walls, which are widely used as an external enclosure and decorative structure. In this paper, a debonding detection method for hidden frame supported glass curtain walls is developed based on nonlinear ultrasonic modulation and piezoceramic transducers. First, the excitation frequency was determined according to the response characteristics. Then, empirical mode decomposition (EMD) was applied to extract the feature components. After discrete Fourier transform (DFT), the nonlinear coefficients were calculated to evaluate the debonding defect. Finally, the experimental setup was established and a series of experiments were carried out to verify the feasibility and effectiveness of the nonlinear ultrasonic modulation method. The nonlinear harmonics detection method was also investigated and it was compared with the nonlinear ultrasonic modulation method. The detection effect at different temperatures and impact were studied. The results showed that the nonlinear coefficient increases with the debonding length. The mean squared error (MSE) of the nonlinear ultrasonic modulation method was improved by 41% compared with the nonlinear harmonics method. The nonlinear ultrasonic modulation method can successfully detect debonding defects in hidden frame supported glass curtain walls at different temperatures and impact.
Collapse
|
11
|
Han W, Zhang L, He H, Liu H, Xing L, Xue X. Self-powered vision electronic-skin basing on piezo-photodetecting Ppy/PVDF pixel-patterned matrix for mimicking vision. NANOTECHNOLOGY 2018; 29:255501. [PMID: 29624184 DOI: 10.1088/1361-6528/aabc28] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
The development of multifunctional electronic-skin that establishes human-machine interfaces, enhances perception abilities or has other distinct biomedical applications is the key to the realization of artificial intelligence. In this paper, a new self-powered (battery-free) flexible vision electronic-skin has been realized from pixel-patterned matrix of piezo-photodetecting PVDF/Ppy film. The electronic-skin under applied deformation can actively output piezoelectric voltage, and the outputting signal can be significantly influenced by UV illumination. The piezoelectric output can act as both the photodetecting signal and electricity power. The reliability is demonstrated over 200 light on-off cycles. The sensing unit matrix of 6 × 6 pixels on the electronic-skin can realize image recognition through mapping multi-point UV stimuli. This self-powered vision electronic-skin that simply mimics human retina may have potential application in vision substitution.
Collapse
Affiliation(s)
- Wuxiao Han
- College of Sciences, Northeastern University, Shenyang, 110004, People's Republic of China
| | | | | | | | | | | |
Collapse
|
12
|
Jia D, Chao J, Li S, Zhang H, Yan Y, Liu T, Sun Y. A Fiber Bragg Grating Sensor for Radial Artery Pulse Waveform Measurement. IEEE Trans Biomed Eng 2018; 65:839-846. [DOI: 10.1109/tbme.2017.2722008] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
13
|
Jiang J, Bitla Y, Huang CW, Do TH, Liu HJ, Hsieh YH, Ma CH, Jang CY, Lai YH, Chiu PW, Wu WW, Chen YC, Zhou YC, Chu YH. Flexible ferroelectric element based on van der Waals heteroepitaxy. SCIENCE ADVANCES 2017; 3:e1700121. [PMID: 28630922 PMCID: PMC5466366 DOI: 10.1126/sciadv.1700121] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
We present a promising technology for nonvolatile flexible electronic devices: A direct fabrication of epitaxial lead zirconium titanate (PZT) on flexible mica substrate via van der Waals epitaxy. These single-crystalline flexible ferroelectric PZT films not only retain their performance, reliability, and thermal stability comparable to those on rigid counterparts in tests of nonvolatile memory elements but also exhibit remarkable mechanical properties with robust operation in bent states (bending radii down to 2.5 mm) and cycling tests (1000 times). This study marks the technological advancement toward realizing much-awaited flexible yet single-crystalline nonvolatile electronic devices for the design and development of flexible, lightweight, and next-generation smart devices with potential applications in electronics, robotics, automotive, health care, industrial, and military systems.
Collapse
Affiliation(s)
- Jie Jiang
- Key Laboratory of Low Dimensional Materials and Application Technology of Ministry of Education, Xiangtan University, Hunan 411105, China
| | - Yugandhar Bitla
- Department of Materials Science and Engineering, National Chiao Tung University, Hsinchu 30010, Taiwan
| | - Chun-Wei Huang
- Department of Materials Science and Engineering, National Chiao Tung University, Hsinchu 30010, Taiwan
| | - Thi Hien Do
- Institute of Physics, Academia Sinica, Taipei 11529, Taiwan
| | - Heng-Jui Liu
- Department of Materials Science and Engineering, National Chung Hsing University, Taichung 40227, Taiwan
| | - Ying-Hui Hsieh
- Department of Materials Science and Engineering, National Chiao Tung University, Hsinchu 30010, Taiwan
| | - Chun-Hao Ma
- Institute of Electronics Engineering, National Tsing Hua University, Hsinchu 30013, Taiwan
| | - Chi-Yuan Jang
- Department of Physics, National Cheng Kung University, Tainan, Taiwan
| | - Yu-Hong Lai
- Department of Materials Science and Engineering, National Chiao Tung University, Hsinchu 30010, Taiwan
| | - Po-Wen Chiu
- Institute of Electronics Engineering, National Tsing Hua University, Hsinchu 30013, Taiwan
| | - Wen-Wei Wu
- Department of Materials Science and Engineering, National Chiao Tung University, Hsinchu 30010, Taiwan
| | - Yi-Chun Chen
- Department of Physics, National Cheng Kung University, Tainan, Taiwan
| | - Yi-Chun Zhou
- Key Laboratory of Low Dimensional Materials and Application Technology of Ministry of Education, Xiangtan University, Hunan 411105, China
- Corresponding author. (Y.-C.Z.); (Y.-H.C.)
| | - Ying-Hao Chu
- Department of Materials Science and Engineering, National Chiao Tung University, Hsinchu 30010, Taiwan
- Institute of Physics, Academia Sinica, Taipei 11529, Taiwan
- Material and Chemical Research Laboratories, Industrial Technology Research Institute, Hsinchu 31040, Taiwan
- Corresponding author. (Y.-C.Z.); (Y.-H.C.)
| |
Collapse
|
14
|
Pullano SA, Mahbub I, Islam SK, Fiorillo AS. PVDF Sensor Stimulated by Infrared Radiation for Temperature Monitoring in Microfluidic Devices. SENSORS 2017; 17:s17040850. [PMID: 28406447 PMCID: PMC5424727 DOI: 10.3390/s17040850] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/05/2017] [Revised: 03/27/2017] [Accepted: 04/11/2017] [Indexed: 11/16/2022]
Abstract
This paper presents a ferroelectric polymer-based temperature sensor designed for microfluidic devices. The integration of the sensor into a system-on-a-chip platform facilitates quick monitoring of localized temperature of a biological fluid, avoiding errors in the evaluation of thermal evolution of the fluid during analysis. The contact temperature sensor is fabricated by combining a thin pyroelectric film together with an infrared source, which stimulates the active element located on the top of the microfluidic channel. An experimental setup was assembled to validate the analytical model and to characterize the response rate of the device. The evaluation procedure and the operating range of the temperature also make this device suitable for applications where the localized temperature monitoring of biological samples is necessary. Additionally, ease of integration with standard microfluidic devices makes the proposed sensor an attractive option for in situ analysis of biological fluids.
Collapse
Affiliation(s)
- Salvatore A Pullano
- Department of Health Sciences, University Magna Græcia of Catanzaro, Viale Europa, 88100 Catanzaro, Italy.
- Department of Electrical Engineering and Computer Science, University of Tennessee, 1520 Middle Drive, Knoxville, TN 37996, USA.
| | - Ifana Mahbub
- Department of Electrical Engineering and Computer Science, University of Tennessee, 1520 Middle Drive, Knoxville, TN 37996, USA.
| | - Syed K Islam
- Department of Electrical Engineering and Computer Science, University of Tennessee, 1520 Middle Drive, Knoxville, TN 37996, USA.
| | - Antonino S Fiorillo
- Department of Health Sciences, University Magna Græcia of Catanzaro, Viale Europa, 88100 Catanzaro, Italy.
| |
Collapse
|
15
|
Rad MA, Tijjani AS, Ahmad MR, Auwal SM. Finite Element Analysis of Single Cell Stiffness Measurements Using PZT-Integrated Buckling Nanoneedles. SENSORS 2016; 17:s17010014. [PMID: 28025571 PMCID: PMC5298587 DOI: 10.3390/s17010014] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/03/2016] [Revised: 10/26/2016] [Accepted: 11/15/2016] [Indexed: 11/30/2022]
Abstract
This paper proposes a new technique for real-time single cell stiffness measurement using lead zirconate titanate (PZT)-integrated buckling nanoneedles. The PZT and the buckling part of the nanoneedle have been modelled and validated using the ABAQUS software. The two parts are integrated together to function as a single unit. After calibration, the stiffness, Young’s modulus, Poisson’s ratio and sensitivity of the PZT-integrated buckling nanoneedle have been determined to be 0.7100 N·m−1, 123.4700 GPa, 0.3000 and 0.0693 V·m·N−1, respectively. Three Saccharomyces cerevisiae cells have been modelled and validated based on compression tests. The average global stiffness and Young’s modulus of the cells are determined to be 10.8867 ± 0.0094 N·m−1 and 110.7033 ± 0.0081 MPa, respectively. The nanoneedle and the cell have been assembled to measure the local stiffness of the single Saccharomyces cerevisiae cells The local stiffness, Young’s modulus and PZT output voltage of the three different size Saccharomyces cerevisiae have been determined at different environmental conditions. We investigated that, at low temperature the stiffness value is low to adapt to the change in the environmental condition. As a result, Saccharomyces cerevisiae becomes vulnerable to viral and bacterial attacks. Therefore, the proposed technique will serve as a quick and accurate process to diagnose diseases at early stage in a cell for effective treatment.
Collapse
Affiliation(s)
- Maryam Alsadat Rad
- Department of Control and Mechatronics Engineering, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, 81310 Skudai, Johor, Malaysia.
| | - Auwal Shehu Tijjani
- Department of Control and Mechatronics Engineering, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, 81310 Skudai, Johor, Malaysia.
| | - Mohd Ridzuan Ahmad
- Department of Control and Mechatronics Engineering, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, 81310 Skudai, Johor, Malaysia.
| | - Shehu Muhammad Auwal
- Department of Control and Mechatronics Engineering, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, 81310 Skudai, Johor, Malaysia.
| |
Collapse
|
16
|
Yoon S, Sim JK, Cho YH. A Flexible and Wearable Human Stress Monitoring Patch. Sci Rep 2016; 6:23468. [PMID: 27004608 PMCID: PMC4804278 DOI: 10.1038/srep23468] [Citation(s) in RCA: 60] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2015] [Accepted: 03/08/2016] [Indexed: 11/18/2022] Open
Abstract
A human stress monitoring patch integrates three sensors of skin temperature, skin conductance, and pulsewave in the size of stamp (25 mm × 15 mm × 72 μm) in order to enhance wearing comfort with small skin contact area and high flexibility. The skin contact area is minimized through the invention of an integrated multi-layer structure and the associated microfabrication process; thus being reduced to 1/125 of that of the conventional single-layer multiple sensors. The patch flexibility is increased mainly by the development of flexible pulsewave sensor, made of a flexible piezoelectric membrane supported by a perforated polyimide membrane. In the human physiological range, the fabricated stress patch measures skin temperature with the sensitivity of 0.31 Ω/°C, skin conductance with the sensitivity of 0.28 μV/0.02 μS, and pulse wave with the response time of 70 msec. The skin-attachable stress patch, capable to detect multimodal bio-signals, shows potential for application to wearable emotion monitoring.
Collapse
Affiliation(s)
- Sunghyun Yoon
- NanoSentuating Systems Laboratory, Cell Bench Research Center Korea Advanced Institute of Science and Technology (KAIST), 271 Daehak-ro, Yuseong-gu, Daejeon 305-701, Republic of Korea
| | - Jai Kyoung Sim
- NanoSentuating Systems Laboratory, Cell Bench Research Center Korea Advanced Institute of Science and Technology (KAIST), 271 Daehak-ro, Yuseong-gu, Daejeon 305-701, Republic of Korea
| | - Young-Ho Cho
- NanoSentuating Systems Laboratory, Cell Bench Research Center Korea Advanced Institute of Science and Technology (KAIST), 271 Daehak-ro, Yuseong-gu, Daejeon 305-701, Republic of Korea
| |
Collapse
|
17
|
Abstract
Chronic nonhealing wounds are a major source of morbidity and mortality in bed-ridden and diabetic patients. Monitoring of physical and chemical parameters important in wound healing and remodeling process can be of immense benefit for optimum management of such lesions. Low-cost flexible polymeric and paper-based substrates are attractive platforms for fabrication of such sensors. In this review, we discuss recent advances in flexible physiochemical sensors for chronic wound monitoring. After a brief introduction to wound healing process and commercial wound dressings, we describe various flexible biocompatible substrates that can be used as the base platform for integration of wound monitoring sensors. We will then discuss several fabrication methods that can be utilized to integrate physical and chemical sensors onto such substrates. Finally, we will present physical and chemical sensors developed for monitoring wound microenvironment and outline future development venues.
Collapse
|
18
|
P(VDF-TrFE) polymer-based thin films deposited on stainless steel substrates treated using water dissociation for flexible tactile sensor development. SENSORS 2013; 13:14777-96. [PMID: 24177729 PMCID: PMC3871078 DOI: 10.3390/s131114777] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/15/2013] [Revised: 10/11/2013] [Accepted: 10/23/2013] [Indexed: 11/16/2022]
Abstract
In this work, deionized (DI) water dissociation was used to treat and change the contact angle of the surface of stainless steel substrates followed by the spin coating of P(VDF-TrFE) material for the fabrication of tactile sensors. The contact angle of the stainless steel surface decreased 14° at −30 V treatment; thus, the adhesion strength between the P(VDF-TrFE) thin film and the stainless steel substrate increased by 90%. Although the adhesion strength was increased at negative voltage treatment, it is observed that the crystallinity value of the P(VDF-TrFE) thin film declined to 37% at −60 V. In addition, the remanent polarization value of the P(VDF-TrFE) thin film declined from 5.6 μC/cm2 to 4.61 μC/cm2 for treatment voltages between −5 V and −60 V. A maximum value of approximately 1000 KV/cm of the coercive field value was obtained with the treatment at −15 V. The d33 value was approximately −10.7 pC/N for the substrate treated at 0 V and reached a minimum of −5 pC/N for treatment at −60 V. By using the P(VDF-TrFE) thin-film as the sensing material for tactile sensors, human pulse measurements were obtained from areas including the carotid, brachial, ankle, radial artery, and apical regions. In addition, the tactile sensor is suitable for monitoring the Cun, Guan, and Chi acupoints located at the radial artery region in Traditional Chinese Medicine (TCM). Waveform measurements of the Cun, Guan, and Chi acupoints are crucial because, in TCM, the various waveforms provided information regarding the health conditions of organs.
Collapse
|