1
|
Rajagopalan V, Venkataraman S, Rajendran DS, Vinoth Kumar V, Kumar VV, Rangasamy G. Acetylcholinesterase biosensors for electrochemical detection of neurotoxic pesticides and acetylcholine neurotransmitter: A literature review. ENVIRONMENTAL RESEARCH 2023; 227:115724. [PMID: 36948285 DOI: 10.1016/j.envres.2023.115724] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Revised: 03/14/2023] [Accepted: 03/18/2023] [Indexed: 05/08/2023]
Abstract
Neurotoxic pesticides are a group of chemicals that pose a severe threat to both human health and the environment. These molecules are also known to accumulate in the food chain and persist in the environment, which can lead to long-term exposure and adverse effects on non-target organisms. The detrimental effects of these pesticides on neurotransmitter levels and function can lead to a range of neurological and behavioral symptoms, which are closely associated with neurodegenerative diseases. Hence, the accurate and reliable detection of these neurotoxic pesticides and associated neurotransmitters is essential for clinical applications, such as diagnosis and treatment. Over the past few decades, acetylcholinesterase (AchE) biosensors have emerged as a sensitive and reliable tool for the electrochemical detection of neurotoxic pesticides and acetylcholine. These biosensors can be tailored to utilize the high specificity and sensitivity of AchE, enabling the detection of these chemicals. Additionally, enzyme immobilization and the incorporation of nanoparticles have further improved the detection capabilities of these biosensors. AchE biosensors have shown tremendous potential in various fields, including environmental monitoring, clinical diagnosis, and pesticide residue analysis. This review summarizes the advancements in AchE biosensors for electrochemical detection of neurotoxic pesticides and acetylcholine over the past two decades.
Collapse
Affiliation(s)
- Vahulabaranan Rajagopalan
- Integrated Bioprocess Laboratory, Department of Biotechnology, School of Bioengineering, SRM Institute of Science and Technology, Kattankulathur, Chennai, 603203, India
| | - Swethaa Venkataraman
- Integrated Bioprocess Laboratory, Department of Biotechnology, School of Bioengineering, SRM Institute of Science and Technology, Kattankulathur, Chennai, 603203, India
| | - Devi Sri Rajendran
- Integrated Bioprocess Laboratory, Department of Biotechnology, School of Bioengineering, SRM Institute of Science and Technology, Kattankulathur, Chennai, 603203, India
| | - Vaidyanathan Vinoth Kumar
- Integrated Bioprocess Laboratory, Department of Biotechnology, School of Bioengineering, SRM Institute of Science and Technology, Kattankulathur, Chennai, 603203, India.
| | - Vaithyanathan Vasanth Kumar
- Department of Electronics and Communication Engineering, Hindustan Institute of Technology and Science, Chennai, India.
| | - Gayathri Rangasamy
- School of Engineering, Lebanese American University, Byblos, Lebanon; University Centre for Research and Development & Department of Civil Engineering, Chandigarh University, Gharuan, Mohali, Punjab, 140413, India.
| |
Collapse
|
2
|
Shamagsumova RV, Vasyk AV, Shurpik DN, Evtugin VG, Stoikov II, Evtugin GA. An Acetylcholinesterase Sensor Based on a Pillar[6]arene–Silver Nanoparticle Composite for the Determination of Drugs for the Treatment of Alzheimer’s Disease. JOURNAL OF ANALYTICAL CHEMISTRY 2022. [DOI: 10.1134/s1061934822040128] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
3
|
Evtyugin GA, Porfir’eva AV. Determination of Organic Compounds in Aqueous–Organic and Dispersed Media Using Electrochemical Methods of Analysis. JOURNAL OF ANALYTICAL CHEMISTRY 2021. [DOI: 10.1134/s1061934821100051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
4
|
Murti BT, Putri AD, Huang YJ, Wei SM, Peng CW, Yang PK. Clinically oriented Alzheimer's biosensors: expanding the horizons towards point-of-care diagnostics and beyond. RSC Adv 2021; 11:20403-20422. [PMID: 35479927 PMCID: PMC9033966 DOI: 10.1039/d1ra01553b] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Accepted: 05/28/2021] [Indexed: 12/30/2022] Open
Abstract
The development of minimally invasive and easy-to-use sensor devices is of current interest for ultrasensitive detection and signal recognition of Alzheimer's disease (AD) biomarkers. Over the years, tremendous effort has been made on diagnostic platforms specifically targeting neurological markers for AD in order to replace the conventional, laborious, and invasive sampling-based approaches. However, the sophistication of analytical outcomes, marker inaccessibility, and material validity strongly limit the current strategies towards effectively predicting AD. Recently, with the promising progress in biosensor technology, the realization of a clinically applicable sensing platform has become a potential option to enable early diagnosis of AD and other neurodegenerative diseases. In this review, various types of biosensors, which include electrochemical, fluorescent, plasmonic, photoelectrochemical, and field-effect transistor (FET)-based sensor configurations, with better clinical applicability and analytical performance towards AD are highlighted. Moreover, the feasibility of these sensors to achieve point-of-care (POC) diagnosis is also discussed. Furthermore, by grafting nanoscale materials into biosensor architecture, the remarkable enhancement in durability, functionality, and analytical outcome of sensor devices is presented. Finally, future perspectives on further translational and commercialization pathways of clinically driven biosensor devices for AD are discussed and summarized.
Collapse
Affiliation(s)
- Bayu Tri Murti
- Graduate Institute of Biomedical Materials and Tissue Engineering, College of Biomedical Engineering, Taipei Medical University Taipei Taiwan
- Semarang College of Pharmaceutical Sciences (STIFAR) Semarang City Indonesia
| | - Athika Darumas Putri
- Semarang College of Pharmaceutical Sciences (STIFAR) Semarang City Indonesia
- Department of Pharmaceutical Sciences, School of Pharmacy, College of Pharmacy, Taipei Medical University Taipei Taiwan
| | - Yi-June Huang
- Graduate Institute of Nanomedicine and Medical Engineering, College of Biomedical Engineering, Taipei Medical University Taipei Taiwan
- International Ph.D. Program in Biomedical Engineering, College of Biomedical Engineering, Taipei Medical University Taipei Taiwan
| | - Shih-Min Wei
- Graduate Institute of Nanomedicine and Medical Engineering, College of Biomedical Engineering, Taipei Medical University Taipei Taiwan
- International Ph.D. Program in Biomedical Engineering, College of Biomedical Engineering, Taipei Medical University Taipei Taiwan
| | - Chih-Wei Peng
- International Ph.D. Program in Biomedical Engineering, College of Biomedical Engineering, Taipei Medical University Taipei Taiwan
- School of Biomedical Engineering, College of Biomedical Engineering, Taipei Medical University Taipei Taiwan
| | - Po-Kang Yang
- Graduate Institute of Nanomedicine and Medical Engineering, College of Biomedical Engineering, Taipei Medical University Taipei Taiwan
- International Ph.D. Program in Biomedical Engineering, College of Biomedical Engineering, Taipei Medical University Taipei Taiwan
- Department of Biomedical Sciences and Engineering, National Central University Chung-li Taiwan
| |
Collapse
|
5
|
A dual-channel optical chemical sensing system for selective detection of nerve agent simulant DFP. Anal Bioanal Chem 2021; 413:4501-4509. [PMID: 34041577 DOI: 10.1007/s00216-021-03413-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Revised: 05/10/2021] [Accepted: 05/17/2021] [Indexed: 10/21/2022]
Abstract
This paper reports a novel optical chemical sensing system for selective detection of diisopropylfluorophosphate (DFP), a simulant of fluorine-containing nerve agents (Sarin and Soman). Contrary to the reported methods involving only single sensing probe, this sensing system is comprised of two molecular sensing probes (1 and 2) having intrinsic affinities for reactive subunits of DFP (electrophilic phosphorus and fluoride ion). On exposure to DFP, two molecular probes react in tandem with electrophilic phosphorus and fluoride ion (by-product of the initial phosphorylation reaction) to induce a unique modulation in the optical properties of the sensing system which leads to selective detection of DFP in solution as interferents like phosphorus-containing compounds, acids, and anions were unable to induce similar optical modulation due to lack of both electrophilic phosphorus and fluorine in the same molecule. Calibration curve between the amount of DFP added and the absorption intensity revealed the colorimetric detection limit of the system to be 4.50 μM which was further lowered to 2.22 μM by making use of a self-immolative fluoride sensing probe 5.
Collapse
|
6
|
Dey N. Use of biocompatible natural product ‘quinine’ for naked-eye sensing of Sarin-surrogate both in solution-state and vapor phase. J Mol Liq 2021. [DOI: 10.1016/j.molliq.2020.114799] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
7
|
Abdelrahman MS, Khattab TA, Kamel S. Hydrazone‐Based Supramolecular Organogel for Selective Chromogenic Detection of Organophosphorus Nerve Agent Mimic. ChemistrySelect 2021. [DOI: 10.1002/slct.202004850] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Affiliation(s)
- Meram S. Abdelrahman
- Dyeing Printing and Auxiliaries Department National Research Centre Cairo 12622 Egypt
| | - Tawfik A. Khattab
- Dyeing Printing and Auxiliaries Department National Research Centre Cairo 12622 Egypt
| | - Samir Kamel
- Chemical Industries Research Division National Research Centre Cairo 12622 Egypt
| |
Collapse
|
8
|
Bu L, Guo L, Xie J. An in situ assay of nerve agents enabled by a self-assembled bienzymatic electrochemical biosensor. NEW J CHEM 2020. [DOI: 10.1039/d0nj00929f] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
A new self-assembled bienzymatic electrochemical biosensor is proposed to in situ detect NAs and readily investigate the inhibition processes of NAs using a single step protocol.
Collapse
Affiliation(s)
- Lijuan Bu
- State Key Laboratory of Toxicology and Medical Countermeasures, and Laboratory of Toxicant Analysis
- Institute of Pharmacology and Toxicology
- Academy of Military Medical Sciences
- Beijing 100850
- P. R. China
| | - Lei Guo
- State Key Laboratory of Toxicology and Medical Countermeasures, and Laboratory of Toxicant Analysis
- Institute of Pharmacology and Toxicology
- Academy of Military Medical Sciences
- Beijing 100850
- P. R. China
| | - Jianwei Xie
- State Key Laboratory of Toxicology and Medical Countermeasures, and Laboratory of Toxicant Analysis
- Institute of Pharmacology and Toxicology
- Academy of Military Medical Sciences
- Beijing 100850
- P. R. China
| |
Collapse
|
9
|
Nabavi SM, Uriarte E, Rastrelli L, Sobarzo-Sánchez E. Aporphines and Alzheimer's Disease: Towards a Medical Approach Facing the Future. Curr Med Chem 2019; 26:3253-3259. [PMID: 29756568 DOI: 10.2174/0929867325666180514102933] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2016] [Revised: 05/26/2017] [Accepted: 06/06/2017] [Indexed: 11/22/2022]
Abstract
Alzheimer's disease (AD) is a neurodegenerative disease that reduces progressively the part cognitive inside the Central Nervous System (CNS) and that affects the memories and emotions of the patients who endure this disease. Many drugs have been assessed in patients with different evolutionary grades of the disease, having diverse results, depending on the used compound. Some of them afford dependence and many others with side effects that affect the emotional part and the economic cost of the treatment. The natural products have diversified their therapeutic uses, and have been used in the treatment of AD in accordance with its easy medical administration and bioavailability. In this review, the use of aporphines in nature for treating Alzheimer's disease, alkaloids isolated from natural and/or synthetic sources have been used principally as cholinesterase inhibitors (acetyl- and butyrylcholinesterase) as galantamine, for instance, though its use has been questioned for being slightly effective or marginal. The use of aporphines give the possibility of generating new treatments with nitrogenous chemical structures of diverse complexity and that are focused in this review comparatively and with real therapeutic scopes.
Collapse
Affiliation(s)
- Seyed Mohammad Nabavi
- Applied Biotechnology Research Center, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Eugenio Uriarte
- Department of Organic Chemistry, Faculty of Pharmacy, University of Santiago de Compostela, 15782 Santiago de Compostela, Spain
| | - Luca Rastrelli
- Dipartimento di Farmacia, Universita degli Studi di Salerno, Via Giovanni Paolo II, 132 - 84084 Fisciano, Italy
| | - Eduardo Sobarzo-Sánchez
- Laboratory of Pharmaceutical Chemistry, Department of Organic Chemistry, Faculty of Pharmacy, University of Santiago de Compostela, 15782 Santiago de Compostela, Spain.,Instituto de Investigación e Innovación en Salud, Facultad de Ciencias de la Salud, Universidad Central de Chile, Santiago, Chile
| |
Collapse
|
10
|
Kostelnik A, Pohanka M. Superficially Bound Acetylcholinesterase Based on a Chitosan Matrix for Neurotoxic Compound Assay by a Photographic Technique. ANAL LETT 2018. [DOI: 10.1080/00032719.2017.1381846] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Affiliation(s)
- Adam Kostelnik
- Faculty of Chemical Technology, University of Pardubice, Pardubice, Czech Republic
- Faculty of Military Health Sciences, University of Defence, Hradec Kralove, Czech Republic
| | - Miroslav Pohanka
- Faculty of Military Health Sciences, University of Defence, Hradec Kralove, Czech Republic
| |
Collapse
|
11
|
Stine KJ. Enzyme Immobilization on Nanoporous Gold: A Review. BIOCHEMISTRY INSIGHTS 2017; 10:1178626417748607. [PMID: 29308011 PMCID: PMC5751899 DOI: 10.1177/1178626417748607] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/25/2017] [Accepted: 11/24/2017] [Indexed: 11/21/2022]
Abstract
Nanoporous gold (referred to as np-Au or NPG) has emerged over the past 10 years as a new support for enzyme immobilization. The material has appealing features of ease of preparation, tunability of pore size, high surface to volume ratio, and compatibility with multiple strategies for enzyme immobilization. The np-Au material is especially of interest for immobilization of redox enzymes for biosensor and biofuel cell applications given the ability to construct electrodes of high surface area and stability. Adjustment of the pore size of np-Au can yield enhancements in enzyme thermal stability. Glucose oxidase immobilization on np-Au has been a focus for development of glucose sensors. Immobilization of laccase and related enzymes has demonstrated the utility of np-Au for construction of biofuel cells. Np-Au has been used to immobilize other redox enzymes, enzyme conjugates for use in bioassays, and enzymes of interest for industrial processes.
Collapse
Affiliation(s)
- Keith J Stine
- Department of Chemistry and Biochemistry, Center for Nanoscience, University of Missouri–St. Louis, St. Louis, MO, USA
| |
Collapse
|
12
|
Construction of an Acetylcholinesterase Sensor Based on Synthesized Paramagnetic Nanoparticles, a Simple Tool for Neurotoxic Compounds Assay. SENSORS 2017; 17:s17040676. [PMID: 28338634 PMCID: PMC5419789 DOI: 10.3390/s17040676] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/01/2017] [Revised: 03/20/2017] [Accepted: 03/22/2017] [Indexed: 12/27/2022]
Abstract
Magnetic particles (MPs) have been widely used in biological applications in recent years as a carrier for various molecules. Their big advantage is in repeated use of immobilized molecules including enzymes. Acetylcholinesterase (AChE) is an enzyme playing crucial role in neurotransmission and the enzyme is targeted by various molecules like Alzheimer's drugs, pesticides and warfare agents. In this work, an electrochemical biosensor having AChE immobilized onto MPs and stabilized through glutaraldehyde (GA) molecule was proposed for assay of the neurotoxic compounds. The prepared nanoparticles were modified by pure AChE and they were used for the measurement anti-Alzheimer's drug galantamine and carbamate pesticide carbofuran with limit of detection 1.5 µM and 20 nM, respectively. All measurements were carried out using screen-printed sensor with carbon working, silver reference, and carbon auxiliary electrode. Standard Ellman's assay was used for validation measurement of both inhibitors. Part of this work was the elimination of reversible inhibitors represented by galantamine from the active site of AChE. For this purpose, we used a lower pH to get the original activity of AChE after inhibition by galantamine. We also observed decarbamylation of the AChE-carbofuran adduct. Influence of organic solvents to AChE as well as repeatability of measurement with MPs with AChE was also established.
Collapse
|
13
|
Affiliation(s)
- Šárka Štěpánková
- Faculty of Chemical Technology, Department of Biological and Biochemical Sciences, University of Pardubice, Pardubice, Czech Republic
| | - Katarína Vorčáková
- Faculty of Chemical Technology, Department of Biological and Biochemical Sciences, University of Pardubice, Pardubice, Czech Republic
| |
Collapse
|
14
|
Ganina TA, Chertkov VA. Dynamic structure of organic compounds in solution according to NMR data and quantum mechanical calculations: I. Soman. RUSSIAN JOURNAL OF ORGANIC CHEMISTRY 2016. [DOI: 10.1134/s1070428016040023] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
15
|
Alkanaimsh S, Karuppanan K, Guerrero A, Tu AM, Hashimoto B, Hwang MS, Phu ML, Arzola L, Lebrilla CB, Dandekar AM, Falk BW, Nandi S, Rodriguez RL, McDonald KA. Transient Expression of Tetrameric Recombinant Human Butyrylcholinesterase in Nicotiana benthamiana. FRONTIERS IN PLANT SCIENCE 2016; 7:743. [PMID: 27379103 PMCID: PMC4909763 DOI: 10.3389/fpls.2016.00743] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2015] [Accepted: 05/17/2016] [Indexed: 05/08/2023]
Abstract
To optimize the expression, extraction and purification of plant-derived tetrameric recombinant human butyrylcholinesterase (prBChE), we describe the development and use of plant viral amplicon-based gene expression system; Tobacco Mosaic Virus (TMV) RNA-based overexpression vector (TRBO) to express enzymatically active FLAG-tagged plant made recombinant butyrylcholinesterase (rBChE) in Nicotiana benthamiana leaves using transient agroinfiltration. Two gene expression cassettes were designed to express the recombinant protein in either the ER or to the apoplastic compartment. Leaf homogenization was used to isolate ER-retained recombinant butyrylcholinesterase (prBChE-ER) while apoplast-targeted rBChE was isolated by either leaf homogenization (prBChE) or vacuum-extraction of apoplastic wash fluid (prBChE-AWF). rBChE from apoplast wash fluid had a higher specific activity but lower enzyme yield than leaf homogenate. To optimize the isolation and purification of total recombinant protein from leaf homogenates, an acidic extraction buffer was used. The acidic extraction buffer yielded >95% enzymatically active tetrameric rBChE as verified by Coomassie stained and native gel electrophoresis. Furthermore, when compared to human butyrylcholinesterase, the prBChE was found to be similar in terms of tetramerization and enzyme kinetics. The N-linked glycan profile of purified prBChE-ER was found to be mostly high mannose structures while the N-linked glycans on prBChE-AWF were primarily complex. The glycan profile of the prBChE leaf homogenates showed a mixture of high mannose, complex and paucimannose type N-glycans. These findings demonstrate the ability of plants to produce rBChE that is enzymatically active and whose oligomeric state is comparable to mammalian butyrylcholinesterase. The process of plant made rBChE tetramerization and strategies for improving its pharmacokinetics properties are also discussed.
Collapse
Affiliation(s)
- Salem Alkanaimsh
- Department of Chemical Engineering, University of California, DavisDavis, CA, USA
| | - Kalimuthu Karuppanan
- Department of Chemical Engineering, University of California, DavisDavis, CA, USA
| | - Andrés Guerrero
- Department of Chemistry, University of California, DavisDavis, CA, USA
| | - Aye M. Tu
- Department of Plant Science, University of California, DavisDavis, CA, USA
| | - Bryce Hashimoto
- Department of Chemical Engineering, University of California, DavisDavis, CA, USA
| | - Min Sook Hwang
- Department of Plant Pathology, University of California, DavisDavis, CA, USA
| | - My L. Phu
- Department of Plant Science, University of California, DavisDavis, CA, USA
| | - Lucas Arzola
- Department of Chemical Engineering, University of California, DavisDavis, CA, USA
| | | | - Abhaya M. Dandekar
- Department of Plant Science, University of California, DavisDavis, CA, USA
| | - Bryce W. Falk
- Department of Plant Pathology, University of California, DavisDavis, CA, USA
| | - Somen Nandi
- Department of Molecular and Cellular Biology, University of California, DavisDavis, CA, USA
- Department of Global HealthShare Initiative, University of California, DavisDavis, CA, USA
| | - Raymond L. Rodriguez
- Department of Molecular and Cellular Biology, University of California, DavisDavis, CA, USA
- Department of Global HealthShare Initiative, University of California, DavisDavis, CA, USA
| | - Karen A. McDonald
- Department of Chemical Engineering, University of California, DavisDavis, CA, USA
- Department of Global HealthShare Initiative, University of California, DavisDavis, CA, USA
- *Correspondence: Karen A. McDonald,
| |
Collapse
|
16
|
Mulyasuryani A, Prasetyawan S. Organophosphate Hydrolase in Conductometric Biosensor for the Detection of Organophosphate Pesticides. ANALYTICAL CHEMISTRY INSIGHTS 2015; 10:23-7. [PMID: 26483607 PMCID: PMC4599581 DOI: 10.4137/aci.s30656] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/15/2015] [Revised: 08/20/2015] [Accepted: 09/01/2015] [Indexed: 01/14/2023]
Abstract
The research has developed an enzyme biosensor for the detection organophosphate pesticide residues. The biosensor consists of a pair of screen-printed carbon electrode (SPCEs). One of electrodes contains immobilized organophosphate hydrolase (OPH) on a chitosan membrane by cross-linking it with glutaraldehyde. The area of the electrodes was optimized to 3, 5, and 7 mm(2). The OPH was isolated from Pseudomonas putida, and was purified by the ammonium sulfate precipitation method, with 6444 ppm (A) and 7865 ppm (B). The organophosphate pesticide samples were 0-100 ppb in tris-acetate buffer 0.05 M, pH 8.5. The results showed that the best performance of the biosensor was achieved by the enzyme A with an electrode area of 5 mm(2). The sensitivity of the biosensor was between 3 and 32 µS/ppb, and the detection limit for the organophosphate pesticides was 40 ppb (diazinon), 30 ppb (malathion), 20 ppb (chlorpyrifos), and 40 ppm (profenofos).
Collapse
Affiliation(s)
- Ani Mulyasuryani
- Chemistry Department, Faculty of Mathematics and Natural Sciences, Brawijaya University, Malang, Indonesia
| | - Sasangka Prasetyawan
- Chemistry Department, Faculty of Mathematics and Natural Sciences, Brawijaya University, Malang, Indonesia
| |
Collapse
|
17
|
Amine A, Arduini F, Moscone D, Palleschi G. Recent advances in biosensors based on enzyme inhibition. Biosens Bioelectron 2015; 76:180-94. [PMID: 26227311 DOI: 10.1016/j.bios.2015.07.010] [Citation(s) in RCA: 114] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2015] [Revised: 06/28/2015] [Accepted: 07/05/2015] [Indexed: 02/07/2023]
Abstract
Enzyme inhibitors like drugs and pollutants are closely correlated to human and environmental health, thus their monitoring is of paramount importance in analytical chemistry. Enzymatic biosensors represent cost-effective, miniaturized and easy to use devices; particularly biosensors based on enzyme inhibition are useful analytical tools for fast screening and monitoring of inhibitors. The present review will highlight the research carried out in the last 9 years (2006-2014) on biosensors based on enzyme inhibition. We underpin the recent advances focused on the investigation in new theoretical approachs and in the evaluation of biosensor performances for reversible and irreversible inhibitors. The use of nanomaterials and microfluidic systems as well as the applications of the various biosensors in real samples is critically reviewed, demonstrating that such biosensors allow the development of useful devices for a fast and reliable alarm system.
Collapse
Affiliation(s)
- A Amine
- Faculty of Sciences and Techniques, University Hassan II of Casablanca, Morocco.
| | - F Arduini
- Dipartimento di Scienze e Tecnologie Chimiche, Università di Roma Tor Vergata, Via della Ricerca Scientifica, 00133 Rome, Italy; Consorzio Interuniversitario Biostrutture e Biosistemi "INBB", Viale Medaglie d'Oro 305, 00136 Rome, Italy
| | - D Moscone
- Dipartimento di Scienze e Tecnologie Chimiche, Università di Roma Tor Vergata, Via della Ricerca Scientifica, 00133 Rome, Italy; Consorzio Interuniversitario Biostrutture e Biosistemi "INBB", Viale Medaglie d'Oro 305, 00136 Rome, Italy
| | - G Palleschi
- Dipartimento di Scienze e Tecnologie Chimiche, Università di Roma Tor Vergata, Via della Ricerca Scientifica, 00133 Rome, Italy; Consorzio Interuniversitario Biostrutture e Biosistemi "INBB", Viale Medaglie d'Oro 305, 00136 Rome, Italy
| |
Collapse
|
18
|
Gainullina ET, Gulikova DK, Korneev DO, Oreshkin DV, Ryzhikov SB, Fateenkov VN. Biosensors as tools of environmental monitoring for organophosphorus nerve agents. JOURNAL OF ANALYTICAL CHEMISTRY 2015. [DOI: 10.1134/s1061934815070047] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
19
|
Ligand immobilization on polydiacetylene-coated and surface-enhanced Raman scattering-encoded beads for label-free detection. J IND ENG CHEM 2015. [DOI: 10.1016/j.jiec.2014.06.010] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
|
20
|
Cifuentes Castro VH, López Valenzuela CL, Salazar Sánchez JC, Peña KP, López Pérez SJ, Ibarra JO, Villagrán AM. An update of the classical and novel methods used for measuring fast neurotransmitters during normal and brain altered function. Curr Neuropharmacol 2014; 12:490-508. [PMID: 25977677 PMCID: PMC4428024 DOI: 10.2174/1570159x13666141223223657] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2014] [Revised: 11/22/2014] [Accepted: 12/19/2014] [Indexed: 11/22/2022] Open
Abstract
To understand better the cerebral functions, several methods have been developed to study the brain activity, they could be related with morphological, electrophysiological, molecular and neurochemical techniques. Monitoring neurotransmitter concentration is a key role to know better how the brain works during normal or pathological conditions, as well as for studying the changes in neurotransmitter concentration with the use of several drugs that could affect or reestablish the normal brain activity. Immediate response of the brain to environmental conditions is related with the release of the fast acting neurotransmission by glutamate (Glu), γ-aminobutyric acid (GABA) and acetylcholine (ACh) through the opening of ligand-operated ion channels. Neurotransmitter release is mainly determined by the classical microdialysis technique, this is generally coupled to high performance liquid chromatography (HPLC). Detection of neurotransmitters can be done by fluorescence, optical density, electrochemistry or other detection systems more sophisticated. Although the microdialysis method is the golden technique to monitor the brain neurotransmitters, it has a poor temporal resolution. Recently, with the use of biosensor the drawback of temporal resolution has been improved considerably, however other inconveniences have merged, such as stability, reproducibility and the lack of reliable biosensors mainly for GABA. The aim of this review is to show the important advances in the different ways to measure neurotransmitter concentrations; both with the use of classic techniques as well as with the novel methods and alternant approaches to improve the temporal resolution.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Alberto Morales Villagrán
- Department of Molecular and Cellular Biology, Camino Ramón Padilla Sánchez 2100, Nextipac, Zapopan,
Jalisco, México, Zip code: 45110, Mexico
| |
Collapse
|
21
|
|
22
|
Yáñez-Sedeño P, Agüí L, Villalonga R, Pingarrón JM. Biosensors in forensic analysis. A review. Anal Chim Acta 2014; 823:1-19. [PMID: 24746348 DOI: 10.1016/j.aca.2014.03.011] [Citation(s) in RCA: 60] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2013] [Revised: 03/09/2014] [Accepted: 03/11/2014] [Indexed: 02/04/2023]
Abstract
Forensic analysis is an important branch of modern Analytical Chemistry with many legal and socially relevant implications. Biosensors can play an important role as efficient tools in this field considering their well known advantages of sensitivity, selectivity, easy functioning, affordability and capability of miniaturization and automation. This article reviews the latest advances in the use of biosensors for forensic analysis. The different methodologies for the transduction of the produced biological events are considered and the applications to forensic toxicological analysis, classified by the nature of the target analytes, as well as those related with chemical and biological weapons critically commented. The article provides several Tables where the more relevant analytical characteristics of the selected reported methods are gathered.
Collapse
Affiliation(s)
- P Yáñez-Sedeño
- University Complutense, Department of Analytical Chemistry, Faculty of Chemistry, Ciudad Universitaria, Madrid 28040, Spain.
| | - L Agüí
- University Complutense, Department of Analytical Chemistry, Faculty of Chemistry, Ciudad Universitaria, Madrid 28040, Spain
| | - R Villalonga
- University Complutense, Department of Analytical Chemistry, Faculty of Chemistry, Ciudad Universitaria, Madrid 28040, Spain
| | - J M Pingarrón
- University Complutense, Department of Analytical Chemistry, Faculty of Chemistry, Ciudad Universitaria, Madrid 28040, Spain
| |
Collapse
|