1
|
Manikandan R, Yoon JH, Chang SC. Emerging Trends in nanostructured materials-coated screen printed electrodes for the electrochemical detection of hazardous heavy metals in environmental matrices. CHEMOSPHERE 2023; 344:140231. [PMID: 37775053 DOI: 10.1016/j.chemosphere.2023.140231] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Revised: 07/18/2023] [Accepted: 09/18/2023] [Indexed: 10/01/2023]
Abstract
Heavy metal ions (HMIs) have become a significant contaminant in recent years. The increase in heavy metal pollution is a serious situation, requiring progressively robust, fast sensing, highly sensitive, and suitable techniques for heavy metal detection. Compared to other classical analytical methods, electroanalytical techniques, especially stripping voltammetric techniques with modified screen-printed electrodes (SPEs), have several advantages, such as fast sensing, great sensitivity, specificity, and long-time stability. Therefore, these techniques are more suitable for HMI detection. In this review, the nanostructured materials used to coat SPEs for the electrochemical determination of HMI are summarized. Additionally, the electrode fabrication method, modification steps, and electroanalytical study of these materials are systematically discussed. Hence, this review will support the researchers in precisely evaluating the electrochemical HMIs detection through highly sensitive stripping voltammetric techniques using SPE modified with nanostructured carbon and their allotropes, metal, metal oxides and their nanocomposites as sensor materials. Moreover, modified electrodes real time detection of HMIs in different food and environmental samples were briefly discussed.
Collapse
Affiliation(s)
- Ramalingam Manikandan
- Department of Cogno-Mechatronics Engineering, College of Nanoscience and Nanotechnology, Pusan National University, Busan, 46241, Republic of Korea
| | - Jang-Hee Yoon
- Busan Centre, Korea Basic Science Institute, Busan, 46742, Republic of Korea
| | - Seung-Cheol Chang
- Department of Cogno-Mechatronics Engineering, College of Nanoscience and Nanotechnology, Pusan National University, Busan, 46241, Republic of Korea.
| |
Collapse
|
2
|
du Plooy J, Jahed N, Iwuoha E, Pokpas K. Advances in paper-based electrochemical immunosensors: review of fabrication strategies and biomedical applications. ROYAL SOCIETY OPEN SCIENCE 2023; 10:230940. [PMID: 38034121 PMCID: PMC10685120 DOI: 10.1098/rsos.230940] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Accepted: 11/03/2023] [Indexed: 12/02/2023]
Abstract
Cellulose paper-based sensing devices have shown promise in addressing the accuracy, sensitivity, selectivity, analysis time and cost of current disease diagnostic tools owing to their excellent physical and physiochemical properties, high surface-area-to-volume ratio, strong adsorption capabilities, ease of chemical functionalization for immobilization, biodegradability, biocompatibility and liquid transport by simple capillary action. This review provides a comprehensive overview of recent advancements in the field of electrochemical immunosensing for various diseases, particularly in underdeveloped regions and globally. It highlights the significant progress in fabrication techniques, fluid control, signal transduction and paper substrates, shedding light on their respective advantages and disadvantages. The primary objective of this review article is to compile recent advances in the field of electrochemical immunosensing for the early detection of diseases prevalent in underdeveloped regions and globally, including cancer biomarkers, bacteria, proteins and viruses. Herein, the critical need for new, simplistic early detection strategies to combat future disease outbreaks and prevent global pandemics is addressed. Moreover, recent advancements in fabrication techniques, including lithography, printing and electrodeposition as well as device orientation, substrate type and electrode modification, have highlighted their potential for enhancing sensitivity and accuracy.
Collapse
Affiliation(s)
- Jarid du Plooy
- SensorLab, Department of Chemistry, University of the Western Cape, Robert Sobukwe Road, Bellville 7535, South Africa
| | - Nazeem Jahed
- SensorLab, Department of Chemistry, University of the Western Cape, Robert Sobukwe Road, Bellville 7535, South Africa
| | - Emmanuel Iwuoha
- SensorLab, Department of Chemistry, University of the Western Cape, Robert Sobukwe Road, Bellville 7535, South Africa
| | - Keagan Pokpas
- SensorLab, Department of Chemistry, University of the Western Cape, Robert Sobukwe Road, Bellville 7535, South Africa
| |
Collapse
|
3
|
Rubino A, Queirós R. Electrochemical determination of heavy metal ions applying screen-printed electrodes based sensors. A review on water and environmental samples analysis. TALANTA OPEN 2023. [DOI: 10.1016/j.talo.2023.100203] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/17/2023] Open
|
4
|
Dabhade AH, Verma RP, Paramasivan B, Kumawat A, Saha B. Development of silver nanoparticles and aptamer conjugated biosensor for rapid detection of E. coli in a water sample. 3 Biotech 2023; 13:244. [PMID: 37346389 PMCID: PMC10279593 DOI: 10.1007/s13205-023-03663-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2023] [Accepted: 06/05/2023] [Indexed: 06/23/2023] Open
Abstract
A simple, rapid, and sensitive electrochemical biosensor based on a screen-printed carbon electrode (SPCE) was developed for onsite detection of E. coli in real time. This work analyzed the effect of aptamer conjugation and PBS buffer solution on the colloidal stability of the silver nanoparticles (AgNPs). Aggregations of the AgNPs after aptamer conjugation in PBS buffer were observed from the particle size distribution analysis. The AgNP-aptamer conjugation and its affinity towards E. coli (DH5α) were confirmed by UV-visible spectrophotometry, which showed a linear increment in the absorption with increasing E.coli concentration. The screen-printed carbon electrodes were modified by drop-casting of AgNPs, which were used as an effective immobilization platform for E. coli-specific aptamers. The modified electrode's surface modification and redox behavior were characterized using cyclic voltammetry. Finally, E. coli was detected using differential pulse voltammetry with an optimized incubation time of 15 min. The developed biosensors showed a linear decrease in current intensity with an increase in the concentration of E. coli. The biosensor had a relative standard deviation (RSD) of 6.91% (n = 3), which showed good reproducibility. The developed biosensors are highly sensitive and have a limit of detection (LOD) as low as 150 CFU/ml. The biosensor showed good selectivity for E.coli coli when comparing the signal response obtained for bacteria other than E.coli. Also, the biosensor was found stable for four weeks at room temperature and showed high recoveries from 95.27% to 107% during the tap water sensitivity validation.
Collapse
Affiliation(s)
- Ajinkya Hariram Dabhade
- Department of Chemical Engineering, National Institute of Technology Rourkela, Rourkela, Odisha 769008 India
| | - Ravi Prakash Verma
- Department of Chemical Engineering, National Institute of Technology Rourkela, Rourkela, Odisha 769008 India
| | - Balasubramanian Paramasivan
- Department of Biotechnology and Medical Engineering, National Institute of Technology Rourkela, Rourkela, Odisha 769008 India
| | - Adhidesh Kumawat
- Department of Chemical Engineering, National Institute of Technology Rourkela, Rourkela, Odisha 769008 India
| | - Biswajit Saha
- Department of Chemical Engineering, Indian Institute of Technology Gandhinagar, Palaj, Gujarat 382355 India
| |
Collapse
|
5
|
Goldoni R, Thomaz DV, Strambini L, Tumedei M, Dongiovanni P, Isola G, Tartaglia G. Quality-by-Design R&D of a Novel Nanozyme-Based Sensor for Saliva Antioxidant Capacity Evaluation. Antioxidants (Basel) 2023; 12:antiox12051120. [PMID: 37237985 DOI: 10.3390/antiox12051120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Revised: 05/14/2023] [Accepted: 05/17/2023] [Indexed: 05/28/2023] Open
Abstract
Oxidative stress is one of the main causes of cell damage, leading to the onset of several diseases, and antioxidants represent a barrier against the production of reactive species. Saliva is receiving increasing interest as a promising biofluid to study the onset of diseases and assess the overall health status of an individual. The antioxidant capacity of saliva can be a useful indicator of the health status of the oral cavity, and it is nowadays evaluated mainly through spectroscopic methods that rely on benchtop machines and liquid reagents. We developed a low-cost screen-printed sensor based on cerium oxide nanoparticles that can be used to assess the antioxidant capacity of biofluids as an alternative to traditional methods. The sensor development process was investigated via a quality-by-design approach to identify the most critical parameters of the process for further optimization. The sensor was tested in the detection of ascorbic acid, which is used as an equivalent in the assessment of overall antioxidant capacity. The LoDs ranged from 0.1147 to 0.3528 mM, while the recoveries varied from 80% to 121.1%, being therefore comparable with those of the golden standard SAT test, whose recovery value was 96.3%. Therefore, the sensor achieved a satisfactory sensitivity and linearity in the range of clinical interest for saliva and was validated against the state-of-the-art equipment for antioxidant capacity evaluation.
Collapse
Affiliation(s)
- Riccardo Goldoni
- Department of Electronics, Information and Bioengineering (DEIB), Politecnico Di Milano, 20133 Milan, Italy
- CNR-Istituto di Elettronica e di Ingegneria dell'Informazione e delle Telecomunicazioni, 56122 Pisa, Italy
| | - Douglas Vieira Thomaz
- National Enterprise for NanoScience and NanoTechnology (NEST), Istituto Nanoscienze-CNR and Scuola Normale Superiore, Piazza San Silvestro 12, 56127 Pisa, Italy
| | - Lucanos Strambini
- CNR-Istituto di Elettronica e di Ingegneria dell'Informazione e delle Telecomunicazioni, 56122 Pisa, Italy
| | - Margherita Tumedei
- Department of Biomedical, Surgical and Dental Sciences, School of Dentistry, University of Milan, 20100 Milan, Italy
- UOC Maxillo-Facial Surgery and Dentistry Fondazione IRCCS Cà Granda, Ospedale Maggiore Policlinico, 20122 Milan, Italy
| | - Paola Dongiovanni
- Medicine and Metabolic Diseases Fondazione IRCCS Cà Granda, Ospedale Maggiore Policlinico, 20122 Milan, Italy
| | - Gaetano Isola
- Department of General Surgery and Surgical-Medical Specialties, School of Dentistry, University of Catania, 95124 Catania, Italy
| | - Gianluca Tartaglia
- Department of Biomedical, Surgical and Dental Sciences, School of Dentistry, University of Milan, 20100 Milan, Italy
- UOC Maxillo-Facial Surgery and Dentistry Fondazione IRCCS Cà Granda, Ospedale Maggiore Policlinico, 20122 Milan, Italy
| |
Collapse
|
6
|
Ivanišević I. The Role of Silver Nanoparticles in Electrochemical Sensors for Aquatic Environmental Analysis. SENSORS (BASEL, SWITZERLAND) 2023; 23:3692. [PMID: 37050752 PMCID: PMC10099384 DOI: 10.3390/s23073692] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 03/30/2023] [Accepted: 03/31/2023] [Indexed: 06/19/2023]
Abstract
With rapidly increasing environmental pollution, there is an urgent need for the development of fast, low-cost, and effective sensing devices for the detection of various organic and inorganic substances. Silver nanoparticles (AgNPs) are well known for their superior optoelectronic and physicochemical properties, and have, therefore, attracted a great deal of interest in the sensor arena. The introduction of AgNPs onto the surface of two-dimensional (2D) structures, incorporation into conductive polymers, or within three-dimensional (3D) nanohybrid architectures is a common strategy to fabricate novel platforms with improved chemical and physical properties for analyte sensing. In the first section of this review, the main wet chemical reduction approaches for the successful synthesis of functional AgNPs for electrochemical sensing applications are discussed. Then, a brief section on the sensing principles of voltammetric and amperometric sensors is given. The current utilization of silver nanoparticles and silver-based composite nanomaterials for the fabrication of voltammetric and amperometric sensors as novel platforms for the detection of environmental pollutants in water matrices is summarized. Finally, the current challenges and future directions for the nanosilver-based electrochemical sensing of environmental pollutants are outlined.
Collapse
Affiliation(s)
- Irena Ivanišević
- Department of General and Inorganic Chemistry, Faculty of Chemical Engineering and Technology, University of Zagreb, Marulićev trg 19, 10000 Zagreb, Croatia
| |
Collapse
|
7
|
Thoeny V, Melnik E, Maier T, Kurzhals S, Derntl C, Pulverer W, Mutinati GC, Asadi M, Mehrabi P, Huetter M, Schalkhammer T, Lieberzeit P, Hainberger R. Comparison of different noble metal-based screen-printed sensors for detection of PIK3CA point-mutations as biomarker for circulating tumor DNA. Electrochim Acta 2023. [DOI: 10.1016/j.electacta.2023.142336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/05/2023]
|
8
|
Torres-Rivero K, Florido A, Martí V, Bastos-Arrieta J. Functionalization of Screen-Printed Electrodes with Grape Stalk Waste Extract-Assisted Synthesized Silver and Gold Nanoparticles: Perspectives of Electrocatalytically Enhanced Determination of Uranyl Ion and Other Heavy Metals Ions. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:1055. [PMID: 36985948 PMCID: PMC10059588 DOI: 10.3390/nano13061055] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 03/10/2023] [Accepted: 03/13/2023] [Indexed: 06/18/2023]
Abstract
Recently, nanotechnology and nanoparticles (NPs) such as AgNPs and AuNPs have become important in analytical chemistry due to their great potential to improve the performance of electrochemical sensors. In this work, Ag and Au nanoparticles have been synthesized using a green route in which a grape stalk waste extract is used as a reducing agent to obtain metallic nanoparticles. These NPs were used to customize the surface of commercial screen-printed electrodes (SPCNFEs). The spin-coating method was used to modify commercial SPCNFEs under a nitrogen atmosphere. The resulting electrodes were used in a determination study of Cd(II), Pb(II), and U(VI) with differential pulse anodic stripping voltammetry (DPASV). The customized green AgNPs and AuNPs electrodes presented higher sensitivity and electroanalytical performance than the non-modified SPCNFE. The results showed that the best analytical parameters were obtained with the green, silver nanoparticle SPCNFEs, with a LOD of 0.12 μg L-1 for Pb(II), which is a lower value compared to the most restrictive regulation guidelines. Additionally, the U(VI) ion was successfully determined using the developed G-AgNPs-SPCNFE in spiked tap water, showing comparable results with the ICP-MS technique.
Collapse
Affiliation(s)
- Karina Torres-Rivero
- Departament d’Enginyeria Química, Escola d’Enginyeria de Barcelona Est (EEBE), Universitat Politècnica de Catalunya, BarcelontaTEch (UPC), Av. Eduard Maristany 16, 08019 Barcelona, Spain
- Barcelona Research Center for Multiscale Science and Engineering, Av. Eduard Maristany 16, 08019 Barcelona, Spain
| | - Antonio Florido
- Departament d’Enginyeria Química, Escola d’Enginyeria de Barcelona Est (EEBE), Universitat Politècnica de Catalunya, BarcelontaTEch (UPC), Av. Eduard Maristany 16, 08019 Barcelona, Spain
- Barcelona Research Center for Multiscale Science and Engineering, Av. Eduard Maristany 16, 08019 Barcelona, Spain
| | - Vicenç Martí
- Departament d’Enginyeria Química, Escola d’Enginyeria de Barcelona Est (EEBE), Universitat Politècnica de Catalunya, BarcelontaTEch (UPC), Av. Eduard Maristany 16, 08019 Barcelona, Spain
- Barcelona Research Center for Multiscale Science and Engineering, Av. Eduard Maristany 16, 08019 Barcelona, Spain
| | - Julio Bastos-Arrieta
- Departament d’Enginyeria Química i Química Analítica, Facultat de Química, Universitat de Barcelona, Martí i Franquès 1-11, 08028 Barcelona, Spain
- Institut de Recerca de l’Aigua (IdRA), Universitat de Barcelona (UB), 08028 Barcelona, Spain
| |
Collapse
|
9
|
Determination of Heavy Metal Ions in Infant Milk Powder Using a Nanoporous Carbon Modified Disposable Sensor. Foods 2023; 12:foods12040730. [PMID: 36832804 PMCID: PMC9956227 DOI: 10.3390/foods12040730] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2023] [Revised: 01/30/2023] [Accepted: 02/04/2023] [Indexed: 02/10/2023] Open
Abstract
Due to the risk of heavy metal pollution in infant milk powder, it is significant to establish effective detection methods. Here, a screen-printed electrode (SPE) was modified with nanoporous carbon (NPC) to detect Pb(II) and Cd(II) in infant milk powder using an electrochemical method. Using NPC as a functional nanolayer facilitated the electrochemical detection of Pb(II) and Cd(II) due to its efficient mass transport and large adsorption capacity. Linear responses were obtained for Pb (II) and Cd(II) in the range from 1 to 60 µg L-1 and 5 to 70 µg L-1, respectively. The limit of detection was 0.1 µg L-1 for Pb(II) and 1.67 µg L-1 for Cd(II). The reproducibility, stability, and anti-interference performance of the prepared sensor were tested as well. The heavy metal ion detection performance in the extracted infant milk powder shows that the developed SPE/NPC possesses the ability to detect Pb(II) and Cd(II) in milk powder.
Collapse
|
10
|
Screen-printed electrochemical sensors for environmental monitoring of heavy metal ion detection. REV CHEM ENG 2022. [DOI: 10.1515/revce-2022-0002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Abstract
Heavy metal ions (HMIs) are known to cause severe damages to the human body and ecological environment. And considering the current alarming situation, it is crucial to develop a rapid, sensitive, robust, economical and convenient method for their detection. Screen printed electrochemical technology contributes greatly to this task, and has achieved global attention. It enabled the mass transmission rate and demonstrated ability to control the chemical nature of the measure media. Besides, the technique offers advantages like linear output, quick response, high selectivity, sensitivity and stability along with low power requirement and high signal-to-noise ratio. Recently, the performance of SPEs has been improved employing the most effective and promising method of the incorporation of different nanomaterials into SPEs. Especially, in electrochemical sensors, the incorporation of nanomaterials has gained extensive attention for HMIs detection as it exhibits outstanding features like broad electrochemical window, large surface area, high conductivity, selectivity and stability. The present review focuses on the recent progress in the field of screen-printed electrochemical sensors for HMIs detection using nanomaterials. Different fabrication methods of SPEs and their utilization for real sample analysis of HMIs using various nanomaterials have been extensively discussed. Additionally, advancement made in this field is also discussed taking help of the recent literature.
Collapse
|
11
|
Simultaneous determination of iron and copper using screen-printed carbon electrodes by adsorptive stripping voltammetry with o-phenanthroline. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107597] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
12
|
Kartika AE, Setiyanto H, Manurung RV, Jenie SNA, Saraswaty V. Silver Nanoparticles Coupled with Graphene Nanoplatelets Modified Screen-Printed Carbon Electrodes for Rhodamine B Detection in Food Products. ACS OMEGA 2021; 6:31477-31484. [PMID: 34869974 PMCID: PMC8637599 DOI: 10.1021/acsomega.1c03414] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Accepted: 11/09/2021] [Indexed: 05/05/2023]
Abstract
A rapid, simple, and sensitive voltammetric sensor has been fabricated to determine Rhodamine B (RhB), a textile coloring agent. Silver nanoparticles (AgNPs) were synthesized by the chemical reduction method of silver nitrate and sodium citrate. Graphene nanoplatelets (GPLs) and AgNPs were drop-casted on the surface of a working electrode of a screen-printed carbon electrode (SPCE), forming the SPCE-GPLs/AgNPs samples. Scanning electron microscopy-energy dispersive X-ray and cyclic voltammetry confirmed the altered surface of the SPCE. The square wave voltammetry was used for the electrochemical determination of RhB. The SPCE-GPLs/AgNPs demonstrated electrochemical responses to detect RhB with a linear range of 2-100 μM, and the limit of detection was 1.94 μM. The SPCE-GPLs/AgNPs demonstrated a selective detection of RhB in the presence of common interfering compounds present in the food samples, including sucrose and monosodium glutamate. Furthermore, the sensor presented good reproducibility as well as repeatability in the detection of RhB. When the sensor was used to determine RhB in an actual food sample, similar results were shown as suggested by UV-vis spectroscopy analysis. Hence, the fabricated sensor can be applied for the detection of RhB in food samples.
Collapse
Affiliation(s)
- Andi Eka Kartika
- Department
of Chemistry (Analytical Chemistry Research Group), Faculty of Mathematics
and Natural Sciences, Bandung Institute
of Technology, Bandung 40132, Indonesia
| | - Henry Setiyanto
- Department
of Chemistry (Analytical Chemistry Research Group), Faculty of Mathematics
and Natural Sciences, Bandung Institute
of Technology, Bandung 40132, Indonesia
- . Fax: +62-22-2504154. Phone: +62-22-2502103
| | - Robeth Viktoria Manurung
- Research
Center for Electronics & Telecommunication, National Research and Innovation Agency Republic of Indonesia, Bandung 40135, Indonesia
- . Phone: +62 815 871 4667
| | - Siti Nurul Aisyiyah Jenie
- Research
Center for Chemistry, National Research
and Innovation Agency Republic of Indonesia, Tangerang Selatan 15314 Indonesia
| | - Vienna Saraswaty
- Research
Unit for Clean Technology, National Research
and Innovation Agency Republic of Indonesia, Bandung 40135, Indonesia
| |
Collapse
|
13
|
Mohamad Nor N, Ramli NH, Poobalan H, Qi Tan K, Abdul Razak K. Recent Advancement in Disposable Electrode Modified with Nanomaterials for Electrochemical Heavy Metal Sensors. Crit Rev Anal Chem 2021; 53:253-288. [PMID: 34565248 DOI: 10.1080/10408347.2021.1950521] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Heavy metal pollution has gained global attention due to its high toxicity and non-biodegradability, even at a low level of exposure. Therefore, the development of a disposable electrode that is sensitive, simple, portable, rapid, and cost-effective as the sensor platform in electrochemical heavy metal detection is vital. Disposable electrodes have been modified with nanomaterials so that excellent electrochemical properties can be obtained. This review highlights the recent progress in the development of numerous types of disposable electrodes modified with nanomaterials for electrochemical heavy metal detection. The disposable electrodes made from carbon-based, glass-based, and paper-based electrodes are reviewed. In particular, the analytical performance, fabrication technique, and integration design of disposable electrodes modified with metal (such as gold, tin and bismuth), carbon (such as carbon nanotube and graphene), and metal oxide (such as iron oxide and zinc oxide) nanomaterials are summarized. In addition, the role of the nanomaterials in improving the electrochemical performance of the modified disposable electrodes is discussed. Finally, the current challenges and future prospect of the disposable electrode modified with nanomaterials are summarized.
Collapse
Affiliation(s)
- Noorhashimah Mohamad Nor
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia
| | - Nurul Hidayah Ramli
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia
| | - Hemalatha Poobalan
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia
| | - Kai Qi Tan
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia
| | - Khairunisak Abdul Razak
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia.,NanoBiotechnology Research & Innovation (NanoBRI), Institute for Research in Molecular Medicine, Universiti Sains Malaysia, 11800 USM, Pulau Pinang, Malaysia
| |
Collapse
|
14
|
Ivanov R, Czibula C, Teichert C, Bojinov M, Tsakova V. Carbon screen-printed electrodes for substrate-assisted electroless deposition of palladium. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115617] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
15
|
Ehsani A, Rezaei Z, Agah A, Shiri HM, Heidari A. Electrochemical and theoretical investigation of functionalized reduced graphene aerogel modified electrode for lead ions sensing. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106074] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
16
|
Torres-Rivero K, Florido A, Bastos-Arrieta J. Recent Trends in the Improvement of the Electrochemical Response of Screen-Printed Electrodes by Their Modification with Shaped Metal Nanoparticles. SENSORS 2021; 21:s21082596. [PMID: 33917220 PMCID: PMC8067965 DOI: 10.3390/s21082596] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Revised: 03/25/2021] [Accepted: 04/01/2021] [Indexed: 12/04/2022]
Abstract
Novel sensing technologies proposed must fulfill the demands of wastewater treatment plants, the food industry, and environmental control agencies: simple, fast, inexpensive, and reliable methodologies for onsite screening, monitoring, and analysis. These represent alternatives to conventional analytical methods (ICP-MS and LC-MS) that require expensive and non-portable instrumentation. This needs to be controlled by qualified technicians, resulting moreover in a long delay between sampling and high-cost analysis. Electrochemical analysis based on screen-printed electrodes (SPEs) represents an excellent miniaturized and portable alternative due to their disposable character, good reproducibility, and low-cost commercial availability. SPEs application is widely extended, which makes it important to design functionalization strategies to improve their analytical response. In this sense, different types of nanoparticles (NPs) have been used to enhance the electrochemical features of SPEs. NPs size (1–100 nm) provides them with unique optical, mechanical, electrical, and chemical properties that give the modified SPEs increased electrode surface area, increased mass-transport rate, and faster electron transfer. Recent progress in nanoscale material science has led to the creation of reproducible, customizable, and simple synthetic procedures to obtain a wide variety of shaped NPs. This mini-review attempts to present an overview of the enhancement of the electrochemical response of SPEs when NPs with different morphologies are used for their surface modification
Collapse
Affiliation(s)
- Karina Torres-Rivero
- Departament d’Enginyeria Química, Escola d’Enginyeria de Barcelona Est (EEBE), Universitat Politècnica de Catalunya, BarcelonaTEch (UPC), Av. Eduard Maristany 16, 08019 Barcelona, Spain; (K.T.-R.); (A.F.)
- Barcelona Research Center for Multiscale Science and Engineering, Av. Eduard Maristany 16, 08019 Barcelona, Spain
| | - Antonio Florido
- Departament d’Enginyeria Química, Escola d’Enginyeria de Barcelona Est (EEBE), Universitat Politècnica de Catalunya, BarcelonaTEch (UPC), Av. Eduard Maristany 16, 08019 Barcelona, Spain; (K.T.-R.); (A.F.)
- Barcelona Research Center for Multiscale Science and Engineering, Av. Eduard Maristany 16, 08019 Barcelona, Spain
| | - Julio Bastos-Arrieta
- Grup de Biotecnologia Molecular i Industrial, Universitat Politècnica de Catalunya, Rambla Sant Nebridi 22, Edifici Gaia TR14, 08222 Terrassa, Spain
- Correspondence:
| |
Collapse
|
17
|
|
18
|
Simon R, Chakraborty S, Konikkara N, Mary NL. Functionalized polystyrene maleic anhydride copolymer/ZnO nanocomposites for enhanced electrochemical performance. J Appl Polym Sci 2020. [DOI: 10.1002/app.48945] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Affiliation(s)
- Remya Simon
- Department of Chemistry, Stella Maris College (Autonomous)University of Madras Chennai 600086 Tamil Nadu India
| | - Sohini Chakraborty
- Department of Chemistry, Stella Maris College (Autonomous)University of Madras Chennai 600086 Tamil Nadu India
| | - Niketha Konikkara
- Department of Physics, Stella Maris College (Autonomous)University of Madras Chennai 600086 Tamil Nadu India
| | - N. L. Mary
- Department of Chemistry, Stella Maris College (Autonomous)University of Madras Chennai 600086 Tamil Nadu India
| |
Collapse
|
19
|
Torres-Rivero K, Pérez-Ràfols C, Bastos-Arrieta J, Florido A, Martí V, Serrano N. Direct As(V) Determination Using Screen-Printed Electrodes Modified with Silver Manoparticles. NANOMATERIALS 2020; 10:nano10071280. [PMID: 32629854 PMCID: PMC7408004 DOI: 10.3390/nano10071280] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/30/2020] [Revised: 06/17/2020] [Accepted: 06/25/2020] [Indexed: 11/16/2022]
Abstract
Carbon-nanofiber-based screen-printed electrodes modified with silver nanoparticles (Ag-NP-SPCNFEs) were tested in a pioneering manner for the direct determination of As(V) at low μg L-1 levels by means of differential pulse anodic stripping voltammetry. Screen-printed electrodes were modified with two different types of Ag-NPs, nanoseeds (NS), and nanoprisms (NPr) and characterized both microscopically and electrochemically. Furthermore, after optimizing the direct voltammetric determination of As(V), the analytical performance of considered sensors was compared for the direct determination of As(V). These results suggest that Ag-NS offer a better analytical response compared to Ag-NPr, with a detection and quantification limit of 0.6 and 1.9 µg L-1, respectively. The proposed methodology was validated using a spiked tap water sample with a very high reproducibility and good agreement with inductively coupled plasma - mass spectrometry (ICP-MS) measurements.
Collapse
Affiliation(s)
- Karina Torres-Rivero
- Departament d’Enginyeria Química, Escola d’Enginyeria de Barcelona Est (EEBE), Universitat Politècnica de Catalunya, BarcelonaTEch (UPC), Av. Eduard Maristany 16, 08019 Barcelona, Spain; (K.T.-R.); (A.F.); (V.M.)
- Barcelona Research Center for Multiscale Science and Engineering, Av. Eduard Maristany 16, 08019 Barcelona, Spain
| | - Clara Pérez-Ràfols
- Departament d’Enginyeria Química i Química Analítica, Facultat de Química, Universitat de Barcelona, Martí i Franquès 1-11, 08028 Barcelona, Spain;
| | - Julio Bastos-Arrieta
- Physical Chemistry, Technische Universität Dresden, Zellescher Weg 19, 01069 Dresden, Germany
- Correspondence: (J.B.-A.); (N.S.)
| | - Antonio Florido
- Departament d’Enginyeria Química, Escola d’Enginyeria de Barcelona Est (EEBE), Universitat Politècnica de Catalunya, BarcelonaTEch (UPC), Av. Eduard Maristany 16, 08019 Barcelona, Spain; (K.T.-R.); (A.F.); (V.M.)
- Barcelona Research Center for Multiscale Science and Engineering, Av. Eduard Maristany 16, 08019 Barcelona, Spain
| | - Vicenç Martí
- Departament d’Enginyeria Química, Escola d’Enginyeria de Barcelona Est (EEBE), Universitat Politècnica de Catalunya, BarcelonaTEch (UPC), Av. Eduard Maristany 16, 08019 Barcelona, Spain; (K.T.-R.); (A.F.); (V.M.)
- Barcelona Research Center for Multiscale Science and Engineering, Av. Eduard Maristany 16, 08019 Barcelona, Spain
- Fundació CTM Centre Tecnològic de Manresa, Plaça de la Ciència 2, 08243 Manresa, Spain
| | - Núria Serrano
- Departament d’Enginyeria Química i Química Analítica, Facultat de Química, Universitat de Barcelona, Martí i Franquès 1-11, 08028 Barcelona, Spain;
- Institut de Recerca de l’Aigua (IdRA), Universitat de Barcelona, Martí i Franquès 1-11, 08028 Barcelona, Spain
- Correspondence: (J.B.-A.); (N.S.)
| |
Collapse
|
20
|
Lee YG, Jang A. Effect of the working and counter/quasi-reference electrode relative area ratio of silver sensor electrodes on voltammetric detection of Pb(II). J IND ENG CHEM 2020. [DOI: 10.1016/j.jiec.2019.08.063] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
21
|
Zhao J, Hu X, Huang X, Jin X, Koh K, Chen H. A facile gold nanoparticles embeded hydrogel for non-enzymatic sensing of glucose. Colloids Surf B Biointerfaces 2019; 183:110404. [PMID: 31394420 DOI: 10.1016/j.colsurfb.2019.110404] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2019] [Revised: 07/20/2019] [Accepted: 07/27/2019] [Indexed: 11/24/2022]
Abstract
The assembly of nanoparticle into electrodes with precise structure and uniform core sizes is important for electrocatalysis. In this study, we reported on a simple strategy for in-situ preparation of gold nanoparticles embedded D-sorbitol hydrogel (D-gel@AuNPs). D-sorbitol hydrogel with acyl hydrazide (D-gel) was synthesized and characterized. AuNP's stable electronic structure, high surface coverage and good conductivity was achieved enabled D-gel@AuNPs exhibits the enhanced electrocatalytic performance. The electrochemical results reveal that the catalytic progress is highly promoted by the D-gel@AuNPs with a detection limit of 0.067 mM and detection range of 0.1-30 mM. The high enzymatic activity and stability provide the high possibility for the development of high value glucose sensors. This mechanistically novel strategy expands the scope of assembly of NPs method for the development of enhanced other electrochemical properties such as amperometric sensing and photcatalysis applications, as well as electrocatalysis.
Collapse
Affiliation(s)
- Jialin Zhao
- Center for Molecular Recognition and Biosensing, School of Life Sciences, Shanghai University, Shanghai 200444, PR China
| | - Xiaojun Hu
- Center for Molecular Recognition and Biosensing, School of Life Sciences, Shanghai University, Shanghai 200444, PR China
| | - Xing Huang
- Center for Molecular Recognition and Biosensing, School of Life Sciences, Shanghai University, Shanghai 200444, PR China; Shanghai Key Laboratory of Bio-Energy Crop, School of Life Sciences, Shanghai University, Shanghai 200444, PR China
| | - Xin Jin
- Center for Molecular Recognition and Biosensing, School of Life Sciences, Shanghai University, Shanghai 200444, PR China
| | - Kwangnak Koh
- Institute of General Education, Pusan National University, Pusan 46241, Republic of Korea.
| | - Hongxia Chen
- Center for Molecular Recognition and Biosensing, School of Life Sciences, Shanghai University, Shanghai 200444, PR China.
| |
Collapse
|
22
|
Torres-Rivero K, Torralba-Cadena L, Espriu-Gascon A, Casas I, Bastos-Arrieta J, Florido A. Strategies for Surface Modification with Ag-Shaped Nanoparticles: Electrocatalytic Enhancement of Screen-Printed Electrodes for the Detection of Heavy Metals. SENSORS 2019; 19:s19194249. [PMID: 31574954 PMCID: PMC6806212 DOI: 10.3390/s19194249] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/01/2019] [Revised: 09/25/2019] [Accepted: 09/26/2019] [Indexed: 02/04/2023]
Abstract
Screen-printed carbon nanofiber electrodes (SPCNFEs) represent an alternative with great acceptance due to their results, as well as their low impact on the environment. In order to improve their performance, in the present work they were modified with silver nanoparticles (Ag-NPs) and electrochemically characterized by using anodic stripping voltammetry. From the Ag-NP synthesis, silver seeds (Ag-NS) and silver nanoprisms (Ag-NPr) were obtained. The Ag-NP formation was confirmed by micrographs, where Ag-NPs with diameters of 12.20 ± 0.04 nm for Ag-NS and 20.40 ± 0.09 nm for Ag-NPr were observed. The electrodes were modified by using three different deposition methods—drop-casting, spin-coating, and in situ approaches—that offer different nanoparticle distribution and electrode modification times. It was observed that the last methodology showed a low amount of Ag-NS deposited on the electrode surface and deep alteration of this surface. Those facts suggest that the in situ synthesis methodology was not appropriate for the determination of heavy metals, and it was discarded. The incorporation of the nanoparticles by spin-coating and drop-casting strategies showed different spatial distribution on the electrode surface, as proved by scanning electron microscopy. The electrodes modified by these strategies were evaluated for the cadmium(II) and lead(II) detection using differential pulse anodic stripping voltammetry, obtaining detection limit values of 2.1 and 2.8 µg·L−1, respectively. The overall results showed that the incorporation route does not directly change the electrocatalytic effect of the nanoparticles, but the shape of these nanoparticles (spherical for seeds and triangular for prisms) has preferential electrocatalytic enhancement over Cd(II) or Pb(II).
Collapse
Affiliation(s)
- Karina Torres-Rivero
- Departament d'Enginyeria Química, Escola d'Enginyeria de Barcelona Est (EEBE), Universitat Politècnica de Catalunya, BarcelonaTEch (UPC), Av. Eduard Maristany 16, 08019 Barcelona, Spain.
- Barcelona Research Center for Multiscale Science and Engineering, Av. Eduard Maristany 16, 08019 Barcelona, Spain.
| | - Lourdes Torralba-Cadena
- Departament d'Enginyeria Química, Escola d'Enginyeria de Barcelona Est (EEBE), Universitat Politècnica de Catalunya, BarcelonaTEch (UPC), Av. Eduard Maristany 16, 08019 Barcelona, Spain.
| | - Alexandra Espriu-Gascon
- Departament d'Enginyeria Química, Escola d'Enginyeria de Barcelona Est (EEBE), Universitat Politècnica de Catalunya, BarcelonaTEch (UPC), Av. Eduard Maristany 16, 08019 Barcelona, Spain.
- Barcelona Research Center for Multiscale Science and Engineering, Av. Eduard Maristany 16, 08019 Barcelona, Spain.
| | - Ignasi Casas
- Departament d'Enginyeria Química, Escola d'Enginyeria de Barcelona Est (EEBE), Universitat Politècnica de Catalunya, BarcelonaTEch (UPC), Av. Eduard Maristany 16, 08019 Barcelona, Spain.
- Barcelona Research Center for Multiscale Science and Engineering, Av. Eduard Maristany 16, 08019 Barcelona, Spain.
| | | | - Antonio Florido
- Departament d'Enginyeria Química, Escola d'Enginyeria de Barcelona Est (EEBE), Universitat Politècnica de Catalunya, BarcelonaTEch (UPC), Av. Eduard Maristany 16, 08019 Barcelona, Spain.
- Barcelona Research Center for Multiscale Science and Engineering, Av. Eduard Maristany 16, 08019 Barcelona, Spain.
| |
Collapse
|
23
|
Screen-printed electrodes modified with green-synthesized gold nanoparticles for the electrochemical determination of aminothiols. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2019.05.066] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
24
|
Liu X, Yao Y, Ying Y, Ping J. Recent advances in nanomaterial-enabled screen-printed electrochemical sensors for heavy metal detection. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.03.021] [Citation(s) in RCA: 117] [Impact Index Per Article: 23.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
25
|
Ghorbani M, Pedramrad T, Aghamohammadhasan M, Seyedin O, Akhlaghi H, Afshar Lahoori N. Simultaneous clean-up and determination of Cu(II), Pb(II) and Cr(III) in real water and food samples using a magnetic dispersive solid phase microextraction and differential pulse voltammetry with a green and novel modified glassy carbon electrode. Microchem J 2019. [DOI: 10.1016/j.microc.2019.03.072] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
26
|
Green Synthesis of Ag Nanoparticles Using Grape Stalk Waste Extract for the Modification of Screen-Printed Electrodes. NANOMATERIALS 2018; 8:nano8110946. [PMID: 30453600 PMCID: PMC6266962 DOI: 10.3390/nano8110946] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/20/2018] [Revised: 11/10/2018] [Accepted: 11/13/2018] [Indexed: 11/24/2022]
Abstract
The chemical synthesis of silver nanoparticles (Ag-NPs) by using an environmentally friendly methodology for their preparation is presented. Thus, considering that plants possess components that can act as reducing agents and stabilizers in nanoparticles’ production, the synthesis of Ag-NPs by using an extract aqueous solution of grape stalk waste as a reducing and capping agent is studied. First, the total polyphenols and reducing sugars contained in the produced extracts at different conditions are characterized. After that, Ag-NPs are synthesized regarding the interaction of Ag ions (from silver nitrate) and the grape stalk extract. The effect of temperature, contact time, extract/metal solution volume ratio and pH solution in the synthesis of metal nanoparticles are also studied. Different sets of nanoparticle samples are characterized by means of Electron Microscopy coupled with Energy Dispersive X-Ray for qualitative chemical identification. Ag-NPs with an average diameter of 27.7 ± 0.6 nm are selected to proof their suitability for sensing purposes. Finally, screen-printed electrodes modified with Ag-NPs are tested for the simultaneous stripping voltammetric determination of Pb(II) and Cd(II). Results indicate good reproducibility, sensitivity and limits of detection around 2.7 µg L−1 for both metal ions.
Collapse
|
27
|
Singh P, Pandit S, Beshay M, Mokkapati V, Garnaes J, Olsson ME, Sultan A, Mackevica A, Mateiu RV, Lütken H, Daugaard AE, Baun A, Mijakovic I. Anti-biofilm effects of gold and silver nanoparticles synthesized by the Rhodiola rosea rhizome extracts. ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY 2018; 46:S886-S899. [DOI: 10.1080/21691401.2018.1518909] [Citation(s) in RCA: 55] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
- Priyanka Singh
- The Novo Nordisk Foundation Center for Biosustainability, Technical University of Denmark, Lyngby, Denmark
| | - Santosh Pandit
- Systems and Synthetic Biology Division, Department of Biology and Biological Engineering, Chalmers University of Technology, Göteborg, Sweden
| | - Mariam Beshay
- Systems and Synthetic Biology Division, Department of Biology and Biological Engineering, Chalmers University of Technology, Göteborg, Sweden
| | - V.R.S.S. Mokkapati
- Systems and Synthetic Biology Division, Department of Biology and Biological Engineering, Chalmers University of Technology, Göteborg, Sweden
| | - Jørgen Garnaes
- Danish Institute of Fundamental Metrology, Lyngby, Denmark
| | - Mikael Emil Olsson
- Department of Environmental Engineering, Technical University of Denmark, Lyngby, Denmark
| | - Abida Sultan
- The Novo Nordisk Foundation Center for Biosustainability, Technical University of Denmark, Lyngby, Denmark
| | - Aiga Mackevica
- Department of Environmental Engineering, Technical University of Denmark, Lyngby, Denmark
| | - Ramona Valentina Mateiu
- CoaST, Department of Chemical and Biochemical Engineering, Technical University of Denmark, Lyngby, Denmark
| | - Henrik Lütken
- Crop Sciences Section, Plant and Environmental Sciences, University of Copenhagen, Taastrup, Denmark
| | - Anders Egede Daugaard
- Danish Polymer Centre, Department of Chemical and Biochemical Engineering, Technical University of Denmark, Lyngby, Denmark
| | - Anders Baun
- Department of Environmental Engineering, Technical University of Denmark, Lyngby, Denmark
| | - Ivan Mijakovic
- The Novo Nordisk Foundation Center for Biosustainability, Technical University of Denmark, Lyngby, Denmark
- Systems and Synthetic Biology Division, Department of Biology and Biological Engineering, Chalmers University of Technology, Göteborg, Sweden
| |
Collapse
|
28
|
He B, Shen XF, Nie J, Wang XL, Liu FM, Yin W, Hou CJ, Huo DQ, Fa HB. Electrochemical sensor using graphene/Fe3O4 nanosheets functionalized with garlic extract for the detection of lead ion. J Solid State Electrochem 2018. [DOI: 10.1007/s10008-018-4041-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
29
|
Bobrowski A, Królicka A, Śliwa J, Zarębski J, Economou A, Kalcher K. Tellurium Film Electrodes Deposited on Carbon and Mesoporous Carbon Screen-printed Substrates for Anodic Stripping Voltammetric Determination of Copper. ELECTROANAL 2018. [DOI: 10.1002/elan.201800165] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Affiliation(s)
- Andrzej Bobrowski
- Department of Building Materials Technology; Faculty of Materials Science and Ceramics; AGH University of Science and Technology; Mickiewicza 30 30-059 Krakow Poland
| | - Agnieszka Królicka
- Department of Building Materials Technology; Faculty of Materials Science and Ceramics; AGH University of Science and Technology; Mickiewicza 30 30-059 Krakow Poland
| | - Julia Śliwa
- Department of Building Materials Technology; Faculty of Materials Science and Ceramics; AGH University of Science and Technology; Mickiewicza 30 30-059 Krakow Poland
| | - Jerzy Zarębski
- Department of Building Materials Technology; Faculty of Materials Science and Ceramics; AGH University of Science and Technology; Mickiewicza 30 30-059 Krakow Poland
| | - Anastasios Economou
- Laboratory of Analytical Chemistry; Department of Chemistry; University of Athens; Athens 157 71 Greece
| | - Kurt Kalcher
- Institute of Chemistry; Analytical Chemistry; Karl-Franzens-University; Universitätsplatz 1 8010 Graz Austria
| |
Collapse
|
30
|
Voltammetric determination of copper in seawater at a glassy carbon disk electrode modified with Au@MnO2 core-shell microspheres. Mikrochim Acta 2018; 185:258. [DOI: 10.1007/s00604-018-2799-1] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2018] [Accepted: 04/12/2018] [Indexed: 12/22/2022]
|
31
|
Li Y, Chen Y, Yu H, Tian L, Wang Z. Portable and smart devices for monitoring heavy metal ions integrated with nanomaterials. Trends Analyt Chem 2018. [DOI: 10.1016/j.trac.2017.11.011] [Citation(s) in RCA: 60] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
|