1
|
Wang L, Wang Y, Wu X, Wang P, Luo X, Lv S. Advances in microneedles for transdermal diagnostics and sensing applications. Mikrochim Acta 2024; 191:406. [PMID: 38898359 DOI: 10.1007/s00604-024-06458-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2024] [Accepted: 05/22/2024] [Indexed: 06/21/2024]
Abstract
Microneedles, the miniaturized needles, which can pierce the skin with minimal invasiveness open up new possibilities for constructing personalized Point-of-Care (POC) diagnostic platforms. Recent advances in microneedle-based POC diagnostic systems, especially their successful implementation with wearable technologies, enable biochemical detection and physiological recordings in a user-friendly manner. This review presents an overview of the current advances in microneedle-based sensor devices, with emphasis on the biological basis of transdermal sensing, fabrication, and application of different types of microneedles, and a summary of microneedle devices based on various sensing strategies. It concludes with the challenges and future prospects of this swiftly growing field. The aim is to present a critical and thorough analysis of the state-of-the-art development of transdermal diagnostics and sensing devices based on microneedles, and to bridge the gap between microneedle technology and pragmatic applications.
Collapse
Affiliation(s)
- Lei Wang
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, Shandong Key Laboratory of Biochemical Analysis, Key Laboratory of Analytical Chemistry for Life Science in Universities of Shandong, College of Chemistry and Molecular Engineering, MOE, Qingdao University of Science and Technology, Qingdao, 266042, China
| | - Yingli Wang
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, Shandong Key Laboratory of Biochemical Analysis, Key Laboratory of Analytical Chemistry for Life Science in Universities of Shandong, College of Chemistry and Molecular Engineering, MOE, Qingdao University of Science and Technology, Qingdao, 266042, China
| | - Xiao Wu
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, Shandong Key Laboratory of Biochemical Analysis, Key Laboratory of Analytical Chemistry for Life Science in Universities of Shandong, College of Chemistry and Molecular Engineering, MOE, Qingdao University of Science and Technology, Qingdao, 266042, China
| | - Peipei Wang
- Department of Rehabilitation Medicine, Qingdao Central Hospital, University of Health and Rehabilitation Sciences, Qingdao, 266000, China
| | - Xiliang Luo
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, Shandong Key Laboratory of Biochemical Analysis, Key Laboratory of Analytical Chemistry for Life Science in Universities of Shandong, College of Chemistry and Molecular Engineering, MOE, Qingdao University of Science and Technology, Qingdao, 266042, China.
| | - Shaoping Lv
- Department of Rehabilitation Medicine, Qingdao Central Hospital, University of Health and Rehabilitation Sciences, Qingdao, 266000, China.
| |
Collapse
|
2
|
Huang X, Yao C, Huang S, Zheng S, Liu Z, Liu J, Wang J, Chen HJ, Xie X. Technological Advances of Wearable Device for Continuous Monitoring of In Vivo Glucose. ACS Sens 2024; 9:1065-1088. [PMID: 38427378 DOI: 10.1021/acssensors.3c01947] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/02/2024]
Abstract
Managing diabetes is a chronic challenge today, requiring monitoring and timely insulin injections to maintain stable blood glucose levels. Traditional clinical testing relies on fingertip or venous blood collection, which has facilitated the emergence of continuous glucose monitoring (CGM) technology to address data limitations. Continuous glucose monitoring technology is recognized for tracking long-term blood glucose fluctuations, and its development, particularly in wearable devices, has given rise to compact and portable continuous glucose monitoring devices, which facilitates the measurement of blood glucose and adjustment of medication. This review introduces the development of wearable CGM-based technologies, including noninvasive methods using body fluids and invasive methods using implantable electrodes. The advantages and disadvantages of these approaches are discussed as well as the use of microneedle arrays in minimally invasive CGM. Microneedle arrays allow for painless transdermal puncture and are expected to facilitate the development of wearable CGM devices. Finally, we discuss the challenges and opportunities and look forward to the biomedical applications and future directions of wearable CGM-based technologies in biological research.
Collapse
Affiliation(s)
- Xinshuo Huang
- State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-Sen University, Guangzhou, 510006, China
| | - Chuanjie Yao
- State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-Sen University, Guangzhou, 510006, China
| | - Shuang Huang
- State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-Sen University, Guangzhou, 510006, China
| | - Shantao Zheng
- State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-Sen University, Guangzhou, 510006, China
| | - Zhengjie Liu
- State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-Sen University, Guangzhou, 510006, China
| | - Jing Liu
- The First Affiliated Hospital of Sun Yat-Sen University, Sun Yat-Sen University, Guangzhou, 510006, China
| | - Ji Wang
- The First Affiliated Hospital of Sun Yat-Sen University, Sun Yat-Sen University, Guangzhou, 510006, China
| | - Hui-Jiuan Chen
- State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-Sen University, Guangzhou, 510006, China
| | - Xi Xie
- State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-Sen University, Guangzhou, 510006, China
- The First Affiliated Hospital of Sun Yat-Sen University, Sun Yat-Sen University, Guangzhou, 510006, China
| |
Collapse
|
3
|
Garg M, Jain N, Kaul S, Rai VK, Nagaich U. Recent advancements in the expedition of microneedles: from lab worktops to diagnostic care centers. Mikrochim Acta 2023; 190:301. [PMID: 37464230 DOI: 10.1007/s00604-023-05859-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Accepted: 05/30/2023] [Indexed: 07/20/2023]
Abstract
Microneedle (MN) technology plays a significant role in bioengineering as it allows for minimally invasive exposure to the skin via the non-invasive procedure, increased drug permeability, and improved biological molecule detectability in the epidermal layers, all while improving therapeutic safety and effectiveness. However, MNs have several significant drawbacks, including difficulty scaling up, variability in drug delivery pattern regarding the skin's external environment, blockage of dermal tissues, induction of inflammatory response at the administration site, and limitation of dosing based on the molecular weight of drug and size. Despite these drawbacks, MNs have emerged as a special transdermal theranostics instrument in clinical research to assess physiological parameters. Bioimaging technology relies on microneedles that can measure particular analytes in the extracellular fluid effectively by crossing the stratum corneum, making them "a unique tool in diagnostics detection and therapeutic application inside the body." This review article discusses the recent advances in the applications especially related to the diagnostics and toxicity challenges of microneedles. In addition, this review article discusses the clinical state and commercial accessibility of microneedle technology-based devices in order to provide new information to scientists and researchers.
Collapse
Affiliation(s)
- Megha Garg
- Department of Pharmaceutics, Amity Institute of Pharmacy, Amity University, Noida, India
| | - Neha Jain
- Department of Pharmaceutics, Amity Institute of Pharmacy, Amity University, Noida, India.
| | - Shreya Kaul
- Department of Pharmaceutics, Amity Institute of Pharmacy, Amity University, Noida, India
| | - Vineet Kumar Rai
- School of Pharmaceutical Sciences, Siksha 'o' Anusandhan University, Bhubaneswar, Odisha, 751003, India
| | - Upendra Nagaich
- Department of Pharmaceutics, Amity Institute of Pharmacy, Amity University, Noida, India.
| |
Collapse
|
4
|
Wang H, Zuo S, Cerezo-Sánchez M, Arekhloo NG, Nazarpour K, Heidari H. Wearable super-resolution muscle-machine interfacing. Front Neurosci 2022; 16:1020546. [PMID: 36466163 PMCID: PMC9714306 DOI: 10.3389/fnins.2022.1020546] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Accepted: 10/21/2022] [Indexed: 09/19/2023] Open
Abstract
Muscles are the actuators of all human actions, from daily work and life to communication and expression of emotions. Myography records the signals from muscle activities as an interface between machine hardware and human wetware, granting direct and natural control of our electronic peripherals. Regardless of the significant progression as of late, the conventional myographic sensors are still incapable of achieving the desired high-resolution and non-invasive recording. This paper presents a critical review of state-of-the-art wearable sensing technologies that measure deeper muscle activity with high spatial resolution, so-called super-resolution. This paper classifies these myographic sensors according to the different signal types (i.e., biomechanical, biochemical, and bioelectrical) they record during measuring muscle activity. By describing the characteristics and current developments with advantages and limitations of each myographic sensor, their capabilities are investigated as a super-resolution myography technique, including: (i) non-invasive and high-density designs of the sensing units and their vulnerability to interferences, (ii) limit-of-detection to register the activity of deep muscles. Finally, this paper concludes with new opportunities in this fast-growing super-resolution myography field and proposes promising future research directions. These advances will enable next-generation muscle-machine interfaces to meet the practical design needs in real-life for healthcare technologies, assistive/rehabilitation robotics, and human augmentation with extended reality.
Collapse
Affiliation(s)
- Huxi Wang
- Microelectronics Lab, James Watt School of Engineering, The University of Glasgow, Glasgow, United Kingdom
- Neuranics Ltd., Glasgow, United Kingdom
| | - Siming Zuo
- Microelectronics Lab, James Watt School of Engineering, The University of Glasgow, Glasgow, United Kingdom
- Neuranics Ltd., Glasgow, United Kingdom
| | - María Cerezo-Sánchez
- Microelectronics Lab, James Watt School of Engineering, The University of Glasgow, Glasgow, United Kingdom
- Neuranics Ltd., Glasgow, United Kingdom
| | - Negin Ghahremani Arekhloo
- Microelectronics Lab, James Watt School of Engineering, The University of Glasgow, Glasgow, United Kingdom
- Neuranics Ltd., Glasgow, United Kingdom
| | - Kianoush Nazarpour
- Neuranics Ltd., Glasgow, United Kingdom
- School of Informatics, The University of Edinburgh, Edinburgh, United Kingdom
| | - Hadi Heidari
- Microelectronics Lab, James Watt School of Engineering, The University of Glasgow, Glasgow, United Kingdom
- Neuranics Ltd., Glasgow, United Kingdom
| |
Collapse
|
5
|
Wang R, Bai J, Zhu X, Li Z, Cheng L, Zhang G, Zhang W. A PDMS-based microneedle array electrode for long-term ECG recording. Biomed Microdevices 2022; 24:27. [PMID: 35953589 DOI: 10.1007/s10544-022-00626-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/01/2022] [Indexed: 11/26/2022]
Abstract
To acquire high-quality electrocardiogram (ECG) signals, traditional Ag/AgCl wet electrodes used together with conductive gel can effectively reduce electrode-skin interface impedance (EII) in a short term. However, their weaknesses of poor flexibility and instability can no longer meet the long-term monitoring requirements of intelligent wearable devices. Owing to the flexible dry electrode without conductive gel, it is a good choice to solve the critical problem on drying-out of conductive gel. Therefore, we develop a flexible microneedle array electrode (FMAE) based on polydimethylsiloxane (PDMS) substrate, which obtains reliable bioelectrical signals by way of penetrating into the stratum corneum (SC) of the skin. The fabrication process, including silicon mold, twice PDMS shape-transferring and encapsulation, has advantages of low cost, repeatable production and good biocompatibility. Afterwards, by comparing the performance with different electrodes, impedance test results indicate that the impedance of FMAE are smaller and more stable, and ECG tests in long term and at resting/jogging states also verify that FMAE can obtain durable, stable and reliable signals. In conclusion, FMAE is promising in long-term ECG monitoring.
Collapse
Affiliation(s)
- Renxin Wang
- State Key Laboratory of Dynamic Testing Technology, North University of China, Taiyuan, 030051, China
- Science and Technology On Sonar Laboratory, Hangzhou, 310000, China
| | - Jianxin Bai
- State Key Laboratory of Dynamic Testing Technology, North University of China, Taiyuan, 030051, China
| | - Xiaohang Zhu
- State Key Laboratory of Dynamic Testing Technology, North University of China, Taiyuan, 030051, China
| | - Zhaodong Li
- State Key Laboratory of Dynamic Testing Technology, North University of China, Taiyuan, 030051, China
| | - Lixia Cheng
- State Key Laboratory of Dynamic Testing Technology, North University of China, Taiyuan, 030051, China
| | - Guojun Zhang
- State Key Laboratory of Dynamic Testing Technology, North University of China, Taiyuan, 030051, China
| | - Wendong Zhang
- State Key Laboratory of Dynamic Testing Technology, North University of China, Taiyuan, 030051, China.
| |
Collapse
|
6
|
|
7
|
Zhu M, Zhang H, Wang X, Wang X, Yang Z, Wang C, Samuel OW, Chen S, Li G. Towards optimizing electrode configurations for silent speech recognition based on high-density surface electromyography. J Neural Eng 2021; 18. [DOI: 10.1088/1741-2552/abca14] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Accepted: 11/12/2020] [Indexed: 11/11/2022]
Abstract
Abstract
Objective. Silent speech recognition (SSR) based on surface electromyography (sEMG) is an attractive non-acoustic modality of human-machine interfaces that convert the neuromuscular electrophysiological signals into computer-readable textual messages. The speaking process involves complex neuromuscular activities spanning a large area over the facial and neck muscles, thus the locations of the sEMG electrodes considerably affected the performance of the SSR system. However, most of the previous studies used only a quite limited number of electrodes that were placed empirically without prior quantitative analysis, resulting in uncertainty and unreliability of the SSR outcomes. Approach. In this study, the technique of high-density sEMG was proposed to provide a full representation of the articulatory muscle activities so that the optimal electrode configuration for SSR could be systemically explored. A total of 120 closely spaced electrodes were placed on the facial and neck muscles to collect the high-density sEMG signals for classifying ten digits (0–9) silently spoken in both English and Chinese. The sequential forward selection algorithm was adopted to explore the optimal electrodes configurations. Main Results. The results showed that the classification accuracy increased rapidly and became saturated quickly when the number of selected electrodes increased from 1 to 120. Using only ten optimal electrodes could achieve a classification accuracy of 86% for English and 94% for Chinese, whereas as many as 40 non-optimized electrodes were required to obtain comparable accuracies. Also, the optimally selected electrodes seemed to be mostly distributed on the neck instead of the facial region, and more electrodes were required for English recognition to achieve the same accuracy. Significance. The findings of this study can provide useful guidelines about electrode placement for developing a clinically feasible SSR system and implementing a promising approach of human-machine interface, especially for patients with speaking difficulties.
Collapse
|
8
|
Affiliation(s)
- Aung Than
- School of Chemical and Biomedical Engineering, Innovative Centre for Flexible DevicesNanyang Technological University Singapore
| | - Ping Zan
- School of Chemical and Biomedical Engineering, Innovative Centre for Flexible DevicesNanyang Technological University Singapore
| | - Peng Chen
- School of Chemical and Biomedical Engineering, Innovative Centre for Flexible DevicesNanyang Technological University Singapore
| |
Collapse
|
9
|
Liu GS, Kong Y, Wang Y, Luo Y, Fan X, Xie X, Yang BR, Wu MX. Microneedles for transdermal diagnostics: Recent advances and new horizons. Biomaterials 2020; 232:119740. [PMID: 31918227 PMCID: PMC7432994 DOI: 10.1016/j.biomaterials.2019.119740] [Citation(s) in RCA: 106] [Impact Index Per Article: 26.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2019] [Revised: 12/21/2019] [Accepted: 12/25/2019] [Indexed: 12/16/2022]
Abstract
Point-of-care testing (POCT), defined as the test performed at or near a patient, has been evolving into a complement to conventional laboratory diagnosis by continually providing portable, cost-effective, and easy-to-use measurement tools. Among them, microneedle-based POCT devices have gained increasing attention from researchers due to the glorious potential for detecting various analytes in a minimally invasive manner. More recently, a novel synergism between microneedle and wearable technologies is expanding their detection capabilities. Herein, we provide an overview on the progress in microneedle-based transdermal biosensors. It covers all the main aspects of the field, including design philosophy, material selection, and working mechanisms as well as the utility of the devices. We also discuss lessons from the past, challenges of the present, and visions for the future on translation of these state-of-the-art technologies from the bench to the bedside.
Collapse
Affiliation(s)
- Gui-Shi Liu
- Guangdong Provincial Key Laboratory of Optical Fiber Sensing and Communications, College of Science & Engineering, Jinan University, Guangzhou, 510632, China
| | - Yifei Kong
- Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA, 02114, USA
| | - Yensheng Wang
- Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA, 02114, USA
| | - Yunhan Luo
- Guangdong Provincial Key Laboratory of Optical Fiber Sensing and Communications, College of Science & Engineering, Jinan University, Guangzhou, 510632, China
| | - Xudong Fan
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, 48109, USA
| | - Xi Xie
- State Key Laboratory of Optoelectronic Materials and Technologies, School of Electronics and Information Technology, Sun Yat-Sen University, Guangzhou, 510006, China.
| | - Bo-Ru Yang
- State Key Laboratory of Optoelectronic Materials and Technologies, School of Electronics and Information Technology, Sun Yat-Sen University, Guangzhou, 510006, China.
| | - Mei X Wu
- Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA, 02114, USA.
| |
Collapse
|