1
|
Gao P, Kasama T, Shin J, Huang Y, Miyake R. A Mediated Enzymatic Electrochemical Sensor Using Paper-Based Laser-Induced Graphene. BIOSENSORS 2022; 12:995. [PMID: 36354502 PMCID: PMC9688852 DOI: 10.3390/bios12110995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Revised: 10/31/2022] [Accepted: 11/05/2022] [Indexed: 06/16/2023]
Abstract
Laser-induced graphene (LIG) has been applied in many different sensing devices, from mechanical sensors to biochemical sensors. In particular, LIG fabricated on paper (PaperLIG) shows great promise for preparing cheap, flexible, and disposable biosensors. Distinct from the fabrication of LIG on polyimide, a two-step process is used for the fabrication of PaperLIG. In this study, firstly, a highly conductive PaperLIG is fabricated. Further characterization of PaperLIG confirmed that it was suitable for developing biosensors. Subsequently, the PaperLIG was used to construct a biosensor by immobilizing glucose oxidase, aminoferrocene, and Nafion on the surface. The developed glucose biosensor could be operated at a low applied potential (-90 mV) for amperometric measurements. The as-prepared biosensor demonstrated a limit of detection of (50-75 µM) and a linear range from 100 µM to 3 mM. The influence of the concentration of the Nafion casting solution on the performance of the developed biosensor was also investigated. Potential interfering species in saliva did not have a noticeable effect on the detection of glucose. Based on the experimental results, the simple-to-prepare PaperLIG-based saliva glucose biosensor shows great promise for application in future diabetes management.
Collapse
Affiliation(s)
- Panpan Gao
- Microfluidic Integrated Circuits Research Laboratory, Bioengineering, School of Engineering, The University of Tokyo, Tokyo 113-8656, Japan
| | - Toshihiro Kasama
- Microfluidic Integrated Circuits Research Laboratory, Bioengineering, School of Engineering, The University of Tokyo, Tokyo 113-8656, Japan
| | - Jungchan Shin
- Microfluidic Integrated Circuits Research Laboratory, Bioengineering, School of Engineering, The University of Tokyo, Tokyo 113-8656, Japan
| | - Yixuan Huang
- Bioengineering, School of Engineering, The University of Tokyo, Tokyo 113-8656, Japan
| | - Ryo Miyake
- Microfluidic Integrated Circuits Research Laboratory, Bioengineering, School of Engineering, The University of Tokyo, Tokyo 113-8656, Japan
| |
Collapse
|
2
|
The development of micro-sized enzyme sensor based on direct electron transfer type open circuit potential sensing principle. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2022.140798] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
3
|
Brown EW, Glasscott MW, Conley K, Barr J, Ray JD, Moores LC, Netchaev A. ACEstat: A DIY Guide to Unlocking the Potential of Integrated Circuit Potentiostats for Open-Source Electrochemical Analysis. Anal Chem 2022; 94:4906-4912. [PMID: 35258920 DOI: 10.1021/acs.analchem.1c04226] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Miniaturization of analytical instrumentation is paramount to enabling convenient in-field sensing. The recent thrust in potentiostat miniaturization for electrochemical sensing and general use has led to the development of commercial application specific integrated circuits (ASICs) that pack all the power of a benchtop instrument into one 5 mm × 5 mm chip. While the capabilities of these integrated circuits far exceed those of open-source potentiostats in the literature, the activation barrier for their implementation requires extensive electrical and software engineering expertise to overcome. In order to more rapidly bring the utility of ASIC potentiostats to researchers, we present a low size, weight, power, and cost (Low SWaP-C) Army Corps of Engineers potentiostat (ACEstat) based on the widely available ADuCM355 offered by Analog Devices. This potentiostat is a streamlined and fully programmable device that leverages industry-leading integrated hardware to perform electrochemical measurements such as cyclic voltammetry, pulse voltammetry, and electrochemical impedance spectroscopy. The ACEstat enables control over a wide range of test parameters and displays results through an intuitive, open-source graphical user interface available on mobile devices and computers. In this report, we present an approachable, do-it-yourself guide to unlocking the capabilities of this integrated circuit potentiostat by outlining the fabrication and programming details necessary to facilitate electroanalysis. Furthermore, we demonstrate the practicality of this device by detecting 2,4,6-trinitrotoluene (TNT) in water at sub-mg/L detection limits, highlighting its potential for in-field use.
Collapse
Affiliation(s)
- Eric W Brown
- U.S. Army Engineer Research and Development Center, Information Technology Laboratory, Vicksburg, Mississippi 39180, United States
| | - Matthew W Glasscott
- U.S. Army Engineer Research and Development Center, Environmental Laboratory, Vicksburg, Mississippi 39180, United States
| | - Keith Conley
- U.S. Army Engineer Research and Development Center, Information Technology Laboratory, Vicksburg, Mississippi 39180, United States
| | - Jesse Barr
- U.S. Army Engineer Research and Development Center, Information Technology Laboratory, Vicksburg, Mississippi 39180, United States
| | - Jason D Ray
- U.S. Army Engineer Research and Development Center, Information Technology Laboratory, Vicksburg, Mississippi 39180, United States
| | - Lee C Moores
- U.S. Army Engineer Research and Development Center, Environmental Laboratory, Vicksburg, Mississippi 39180, United States
| | - Anton Netchaev
- U.S. Army Engineer Research and Development Center, Information Technology Laboratory, Vicksburg, Mississippi 39180, United States
| |
Collapse
|
4
|
Malathi S, Pakrudheen I, Kalkura SN, Webster T, Balasubramanian S. Disposable biosensors based on metal nanoparticles. SENSORS INTERNATIONAL 2022; 3:100169. [PMID: 35252890 PMCID: PMC8889882 DOI: 10.1016/j.sintl.2022.100169] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Revised: 02/28/2022] [Accepted: 03/01/2022] [Indexed: 02/06/2023] Open
Abstract
The coronavirus disease2019 (COVID-19) pandemic has highlighted the need for disposable biosensors that can detect viruses in infected patients quickly due to fast response and also at a low cost.The present review provides an overview of the applications of disposable biosensors based on metal nanoparticles in enzymatic and non-enzymatic sensors with special reference to glucose and H2O2, immunosensors as well as genosensors (DNA biosensors in which the recognized event consists of the hybridization reaction)for point-of-care diagnostics. The disposable biosensors for COVID19 have also been discussed.
Collapse
Affiliation(s)
- S. Malathi
- Crystal Growth Centre, Anna University, Guindy, Chennai, 600025, India
| | - I. Pakrudheen
- Department of Chemistry, CMR Institute of Technology, Bengaluru, 560037, Karnataka, India
| | | | - T.J. Webster
- Department of Chemical Engineering, Northeastern University, Boston, MA, 02115, USA
| | - S. Balasubramanian
- Department of Inorganic Chemistry, University of Madras, Guindy, Chennai, 600025, India,Corresponding author
| |
Collapse
|
5
|
Sharafeldin M, James T, Davis JJ. Open Circuit Potential as a Tool for the Assessment of Binding Kinetics and Reagentless Protein Quantitation. Anal Chem 2021; 93:14748-14754. [PMID: 34699180 DOI: 10.1021/acs.analchem.1c03292] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
A microfluidic open circuit potential label-free protein assay was developed for the reagentless quantification of C-reactive protein (CRP), a model protein target, and further utilized to assess target-receptor binding kinetics. Generated sensors have very high baseline stabilities (<1% change in 100 min) and high levels of selectivity in complex media. Real-time assays are fast (<20 min), of high sensitivity (1 ng/mL limit of detection for CRP in serum), and resolve kinetic and thermodynamic characteristics that correlate well with those resolved optically. The assay shows excellent correlation with an enzyme-linked immunosorbent assay analysis of patient samples. The methodology has value in potentially underpinning a low-cost, rapid, and sensitive single-step biomarker quantification.
Collapse
Affiliation(s)
- Mohamed Sharafeldin
- Department of Chemistry, University of Oxford, South Parks Road, Oxford OX1 3QZ, U.K
| | - Timothy James
- Department of Clinical Biochemistry, Oxford University Hospitals NHS Trust, Oxford OX3 9DU, U.K
| | - Jason J Davis
- Department of Chemistry, University of Oxford, South Parks Road, Oxford OX1 3QZ, U.K
| |
Collapse
|
6
|
Clinical Application of the Novel Cell-Based Biosensor for the Ultra-Rapid Detection of the SARS-CoV-2 S1 Spike Protein Antigen: A Practical Approach. BIOSENSORS 2021; 11:bios11070224. [PMID: 34356695 PMCID: PMC8301797 DOI: 10.3390/bios11070224] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/01/2021] [Revised: 07/01/2021] [Accepted: 07/03/2021] [Indexed: 12/13/2022]
Abstract
The availability of antigen tests for SARS-CoV-2 represents a major step for the mass surveillance of the incidence of infection, especially regarding COVID-19 asymptomatic and/or early-stage patients. Recently, we reported the development of a Bioelectric Recognition Assay-based biosensor able to detect the SARS-CoV-2 S1 spike protein expressed on the surface of the virus in just three minutes, with high sensitivity and selectivity. The working principle was established by measuring the change of the electric potential of membrane-engineered mammalian cells bearing the human chimeric spike S1 antibody after attachment of the respective viral protein. In the present study, we applied the novel biosensor to patient-derived nasopharyngeal samples in a clinical set-up, with absolutely no sample pretreatment. More importantly, membrane-engineered cells were pre-immobilized in a proprietary biomatrix, thus enabling their long-term preservation prior to use as well as significantly increasing their ease-of-handle as test consumables. The plug-and-apply novel biosensor was able to detect the virus in positive samples with a 92.8% success rate compared to RT-PCR. No false negative results were recorded. These findings demonstrate the potential applicability of the biosensor for the early, routine mass screening of SARS-CoV-2 on a scale not yet realized.
Collapse
|
7
|
Printed Electrodes in Microfluidic Arrays for Cancer Biomarker Protein Detection. BIOSENSORS-BASEL 2020; 10:bios10090115. [PMID: 32906644 PMCID: PMC7559629 DOI: 10.3390/bios10090115] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 08/27/2020] [Accepted: 09/01/2020] [Indexed: 12/27/2022]
Abstract
Medical diagnostics is trending towards a more personalized future approach in which multiple tests can be digitized into patient records. In cancer diagnostics, patients can be tested for individual protein and genomic biomarkers that detect cancers at very early stages and also be used to monitor cancer progression or remission during therapy. These data can then be incorporated into patient records that could be easily accessed on a cell phone by a health care professional or the patients themselves on demand. Data on protein biomarkers have a large potential to be measured in point-of-care devices, particularly diagnostic panels that could provide a continually updated, personalized record of a disease like cancer. Electrochemical immunoassays have been popular among protein detection methods due to their inherent high sensitivity and ease of coupling with screen-printed and inkjet-printed electrodes. Integrated chips featuring these kinds of electrodes can be built at low cost and designed for ease of automation. Enzyme-linked immunosorbent assay (ELISA) features are adopted in most of these ultrasensitive detection systems, with microfluidics allowing easy manipulation and good fluid dynamics to deliver reagents and detect the desired proteins. Several of these ultrasensitive systems have detected biomarker panels ranging from four to eight proteins, which in many cases when a specific cancer is suspected may be sufficient. However, a grand challenge lies in engineering microfluidic-printed electrode devices for the simultaneous detection of larger protein panels (e.g., 50-100) that could be used to test for many types of cancers, as well as other diseases for truly personalized care.
Collapse
|
8
|
Smith LA, Glasscott MW, Vannoy KJ, Dick JE. Enzyme Kinetics via Open Circuit Potentiometry. Anal Chem 2019; 92:2266-2273. [PMID: 31830783 DOI: 10.1021/acs.analchem.9b04972] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
We demonstrate the application of open circuit potentiometry (OCP) to measure enzyme turnover kinetics, kturn. The electrode surface will become poised by the addition of a well-behaved redox pair, such as ferrocenemethanol/ferrocenium methanol (FcMeOH/FcMeOH+), which acts as the cosubstrate for the enzymatic process. A measurable change in potential results when an enzyme consumes the one-electron transfer mediator. Glucose oxidase was studied as a test-case, but the method is generalizable across oxidoreductase enzymes that rely on electron transfer mediators. In the presence of glucose and FcMeOH+, glucose oxidase delivers electrons to FcMeOH+, and the potential changes with respect to the Nernst equation. A theoretical model incorporating enzymatic rate expressions into the Nernst equation was derived to explain the observed potential transients, and experimental data fit theory well. A similar experiment was performed using amperometry on ultramicroelectrodes (UMEs). Here, the same enzymatic rate expression may be incorporated into the equation for steady-state flux to an UME to obtain kturn. While similar kinetic information was obtained from the potentiometric and amperometric responses, potentiometry is independent of electrode size and mass transfer effects. Finally, we show how kturn changes as a function of one-electron mediator. Our results may eventually find applications to biosensors, where electrode fouling plagues long-term sensor performance.
Collapse
Affiliation(s)
- Lettie A Smith
- Department of Chemistry , The University of North Carolina at Chapel Hill , Chapel Hill , North Carolina 27599 , United States
| | - Matthew W Glasscott
- Department of Chemistry , The University of North Carolina at Chapel Hill , Chapel Hill , North Carolina 27599 , United States
| | - Kathryn J Vannoy
- Department of Chemistry , The University of North Carolina at Chapel Hill , Chapel Hill , North Carolina 27599 , United States
| | - Jeffrey E Dick
- Department of Chemistry , The University of North Carolina at Chapel Hill , Chapel Hill , North Carolina 27599 , United States.,Lineberger Comprehensive Cancer Center, School of Medicine , The University of North Carolina at Chapel Hill , Chapel Hill , North Carolina 27599 , United States
| |
Collapse
|
9
|
Crossley L, Attoye B, Vezza V, Blair E, Corrigan DK, Hannah S. Establishing a Field-Effect Transistor Sensor for the Detection of Mutations in the Tumour Protein 53 Gene (TP53)-An Electrochemical Optimisation Approach. BIOSENSORS-BASEL 2019; 9:bios9040141. [PMID: 31817717 PMCID: PMC6956290 DOI: 10.3390/bios9040141] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/01/2019] [Revised: 11/28/2019] [Accepted: 12/04/2019] [Indexed: 11/30/2022]
Abstract
We present a low-cost, sensitive and specific DNA field-effect transistor sensor for the rapid detection of a common mutation to the tumour protein 53 gene (TP53). The sensor consists of a commercially available, low-cost, field-effect transistor attached in series to a gold electrode sensing pad for DNA hybridisation. The sensor has been predominantly optimised electrochemically, particularly with respect to open-circuit potentiometry as a route towards understanding potential (voltage) changes upon DNA hybridisation using a transistor. The developed sensor responds sensitively to TP53 mutant DNA as low as 100 nM concentration. The sensor responds linearly as a function of DNA target concentration and is able to differentiate between complementary and noncomplementary DNA target sequences.
Collapse
|
10
|
Metwally S, Stachewicz U. Surface potential and charges impact on cell responses on biomaterials interfaces for medical applications. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2019; 104:109883. [DOI: 10.1016/j.msec.2019.109883] [Citation(s) in RCA: 92] [Impact Index Per Article: 18.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2019] [Revised: 05/02/2019] [Accepted: 06/11/2019] [Indexed: 12/12/2022]
|
11
|
Martín-Yerga D. Electrochemical Detection and Characterization of Nanoparticles with Printed Devices. BIOSENSORS 2019; 9:E47. [PMID: 30925772 PMCID: PMC6627282 DOI: 10.3390/bios9020047] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/24/2019] [Revised: 03/16/2019] [Accepted: 03/25/2019] [Indexed: 12/15/2022]
Abstract
Innovative methods to achieve the user-friendly, quick, and highly sensitive detection of nanomaterials are urgently needed. Nanomaterials have increased importance in commercial products, and there are concerns about the potential risk that they entail for the environment. In addition, detection of nanomaterials can be a highly valuable tool in many applications, such as biosensing. Electrochemical methods using disposable, low-cost, printed electrodes provide excellent analytical performance for the detection of a wide set of nanomaterials. In this review, the foundations and latest advances of several electrochemical strategies for the detection of nanoparticles using cost-effective printed devices are introduced. These strategies will equip the experimentalist with an extensive toolbox for the detection of nanoparticles of different chemical nature and possible applications ranging from quality control to environmental analysis and biosensing.
Collapse
Affiliation(s)
- Daniel Martín-Yerga
- Department of Chemical Engineering, KTH Royal Institute of Technology, 100-44 Stockholm, Sweden.
| |
Collapse
|
12
|
Dąbrowski M, Zimińska A, Kalecki J, Cieplak M, Lisowski W, Maksym R, Shao S, D'Souza F, Kuhn A, Sharma PS. Facile Fabrication of Surface-Imprinted Macroporous Films for Chemosensing of Human Chorionic Gonadotropin Hormone. ACS APPLIED MATERIALS & INTERFACES 2019; 11:9265-9276. [PMID: 30714713 DOI: 10.1021/acsami.8b17951] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
We present an improved approach for the preparation of highly selective and homogeneous molecular cavities in molecularly imprinted polymers (MIPs) via the combination of surface imprinting and semi-covalent imprinting. Toward that, first, a colloidal crystal mold was prepared via the Langmuir-Blodgett (LB) technique. Then, human chorionic gonadotropin (hCG) template protein was immobilized on the colloidal crystal mold. Later, hCG derivatization with electroactive functional monomers via amide chemistry was performed. In a final step, optimized potentiostatic polymerization of 2,3'-bithiophene enabled depositing an MIP film as the macroporous structure. This synergistic strategy resulted in the formation of molecularly imprinted cavities exclusively on the internal surface of the macropores, which were accessible after dissolution of silica molds. The recognition of hCG by the macroporous MIP film was transduced with the help of electric transducers, namely, extended-gate field-effect transistors (EG-FET) and capacitive impedimetry (CI). These readout strategies offered the ability to create chemosensors for the label-free determination of the hCG hormone. Other than the simple confirmation of pregnancy, hCG assay is a common tool for the diagnosis and follow-up of ectopic pregnancy or trophoblast tumors. Concentration measurements with these EG-FET and CI-based devices allowed real-time measurements of hCG in the range of 0.8-50 and 0.17-2.0 fM, respectively, in 10 mM carbonate buffer (pH = 10). Moreover, the selectivity of chemosensors with respect to protein interferences was very high.
Collapse
Affiliation(s)
- Marcin Dąbrowski
- Institute of Physical Chemistry , Polish Academy of Sciences , Kasprzaka 44/52 , 01-224 Warsaw , Poland
| | - Agnieszka Zimińska
- Institute of Physical Chemistry , Polish Academy of Sciences , Kasprzaka 44/52 , 01-224 Warsaw , Poland
- Department of Biomaterials Chemistry, Faculty of Pharmacy with Laboratory Medicine Division , Medical University of Warsaw , Banacha 1 , 02-097 Warsaw , Poland
| | - Jakub Kalecki
- Institute of Physical Chemistry , Polish Academy of Sciences , Kasprzaka 44/52 , 01-224 Warsaw , Poland
| | - Maciej Cieplak
- Institute of Physical Chemistry , Polish Academy of Sciences , Kasprzaka 44/52 , 01-224 Warsaw , Poland
| | - Wojciech Lisowski
- Institute of Physical Chemistry , Polish Academy of Sciences , Kasprzaka 44/52 , 01-224 Warsaw , Poland
| | - Radosław Maksym
- Department of Reproductive Health, Center of Postgraduate Medical Education , St. Sophia Hospital , Zelazna 90 , 01-004 Warsaw , Poland
| | - Shuai Shao
- Department of Chemistry , University of North Texas , 1155 Union Circle No. 305070 , Denton , Texas 76203-5017 , United States
| | - Francis D'Souza
- Department of Chemistry , University of North Texas , 1155 Union Circle No. 305070 , Denton , Texas 76203-5017 , United States
| | - Alexander Kuhn
- University of Bordeaux, CNRS UMR 5255, Bordeaux INP, ENSCBP , 16 Avenue Pey Berland , 33607 Pessac , France
| | - Piyush S Sharma
- Institute of Physical Chemistry , Polish Academy of Sciences , Kasprzaka 44/52 , 01-224 Warsaw , Poland
| |
Collapse
|