1
|
Malik S, Singh J, Saini K, Chaudhary V, Umar A, Ibrahim AA, Akbar S, Baskoutas S. Paper-based sensors: affordable, versatile, and emerging analyte detection platforms. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:2777-2809. [PMID: 38639474 DOI: 10.1039/d3ay02258g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/20/2024]
Abstract
Paper-based sensors, often referred to as paper-based analytical devices (PADs), stand as a transformative technology in the field of analytical chemistry. They offer an affordable, versatile, and accessible solution for diverse analyte detection. These sensors harness the unique properties of paper substrates to provide a cost-effective and adaptable platform for rapid analyte detection, spanning chemical species, biomolecules, and pathogens. This review highlights the key attributes that make paper-based sensors an attractive choice for analyte detection. PADs demonstrate their versatility by accommodating a wide range of analytes, from ions and gases to proteins, nucleic acids, and more, with customizable designs for specific applications. Their user-friendly operation and minimal infrastructure requirements suit point-of-care diagnostics, environmental monitoring, food safety, and more. This review also explores various fabrication methods such as inkjet printing, wax printing, screen printing, dip coating, and photolithography. Incorporating nanomaterials and biorecognition elements promises even more sophisticated and sensitive applications.
Collapse
Affiliation(s)
- Sumit Malik
- Department of Chemistry, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, 133203, Haryana, India.
| | - Joginder Singh
- Department of Chemistry, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, 133203, Haryana, India.
| | - Kajal Saini
- Department of Chemistry, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, 133203, Haryana, India.
| | - Vivek Chaudhary
- Department of Chemistry, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, 133203, Haryana, India.
| | - Ahmad Umar
- Department of Chemistry, Faculty of Science and Arts, Promising Centre for Sensors and Electronic Devices (PCSED), Najran University, Najran-11001, Kingdom of Saudi Arabia.
- Department of Materials Science and Engineering, The Ohio State University, Columbus 43210, OH, USA
- STEM Pioneers Training Lab, Najran University, Najran 11001, Kingdom of Saudi Arabia
| | - Ahmed A Ibrahim
- Department of Chemistry, Faculty of Science and Arts, Promising Centre for Sensors and Electronic Devices (PCSED), Najran University, Najran-11001, Kingdom of Saudi Arabia.
- STEM Pioneers Training Lab, Najran University, Najran 11001, Kingdom of Saudi Arabia
| | - Sheikh Akbar
- Department of Materials Science and Engineering, The Ohio State University, Columbus 43210, OH, USA
| | | |
Collapse
|
2
|
Al-Jaf SH, Omer KM. Dual-spot ratiometric microfluidic paper-based analytical device for accuracy and precision improvement. Talanta 2024; 269:125433. [PMID: 38008019 DOI: 10.1016/j.talanta.2023.125433] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 11/09/2023] [Accepted: 11/16/2023] [Indexed: 11/28/2023]
Abstract
Instrumental and environmental fluctuations are common sources of error in smartphone-based optical detection, significantly affecting the accuracy of analytical measurements. In this regard, spotting the sample and reference simultaneously and in close proximity compensates for the fluctuations. This "dual-spot" design is similar to the double-beam technique used in spectrophotometry, which reduces fluctuations in the results. The underlying hypothesis is that any instrumental and/or environmental factors influencing the color intensity in the detection zones will similarly impact the color intensity in the control zone under the same conditions. To test our design, a ratiometric microfluidic paper-based analytical device (μPAD), functionalized with a mixture of green-emissive carbon dots (CDs) and red-emissive ethidium bromide, was developed for the selective detection of ascorbic acid (AA). The green emission of the CDs is quenched by both AA and Fe3+; NaF was thus loaded onto the 3D connector as a masking agent to remove the interference effect of the Fe3+ ions. The color variations were monitored under a UV lamp, using a smartphone to capture the images, and the RGB intensities were processed using the Color Grab application. The proposed double-spot method greatly enhanced the analytical precision and accuracy of the device. A linear working range from 0 to 125 μM was obtained, and the limit of detection was 2.71 μM. The μPAD was successfully used for the detection of AA in human serum, with recoveries from 87.27 to 98.52 %.
Collapse
Affiliation(s)
- Sabah H Al-Jaf
- Department of Chemistry, College of Science, University of Sulaimani, 46002, Sulaimani City, Kurdistan Region, Iraq; Department of Chemistry, College of Science, University of Garmian, Darbandikhan Road, 46021, Kalar City, Sulaimaniyah Province, Kurdistan of Iraq, Iraq
| | - Khalid M Omer
- Department of Chemistry, College of Science, University of Sulaimani, 46002, Sulaimani City, Kurdistan Region, Iraq.
| |
Collapse
|
3
|
Fernández González A, Badía Laíño R, Costa-Fernández JM, Soldado A. Progress and Challenge of Sensors for Dairy Food Safety Monitoring. SENSORS (BASEL, SWITZERLAND) 2024; 24:1383. [PMID: 38474919 DOI: 10.3390/s24051383] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/26/2023] [Revised: 02/15/2024] [Accepted: 02/19/2024] [Indexed: 03/14/2024]
Abstract
One of the most consumed foods is milk and milk products, and guaranteeing the suitability of these products is one of the major concerns in our society. This has led to the development of numerous sensors to enhance quality controls in the food chain. However, this is not a simple task, because it is necessary to establish the parameters to be analyzed and often, not only one compound is responsible for food contamination or degradation. To attempt to address this problem, a multiplex analysis together with a non-directed (e.g., general parameters such as pH) analysis are the most relevant alternatives to identifying the safety of dairy food. In recent years, the use of new technologies in the development of devices/platforms with optical or electrochemical signals has accelerated and intensified the pursuit of systems that provide a simple, rapid, cost-effective, and/or multiparametric response to the presence of contaminants, markers of various diseases, and/or indicators of safety levels. However, achieving the simultaneous determination of two or more analytes in situ, in a single measurement, and in real time, using only one working 'real sensor', remains one of the most daunting challenges, primarily due to the complexity of the sample matrix. To address these requirements, different approaches have been explored. The state of the art on food safety sensors will be summarized in this review including optical, electrochemical, and other sensor-based detection methods such as magnetoelastic or mass-based sensors.
Collapse
Affiliation(s)
- Alfonso Fernández González
- Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, Avda. Julián Clavería 8, 33006 Oviedo, Asturias, Spain
| | - Rosana Badía Laíño
- Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, Avda. Julián Clavería 8, 33006 Oviedo, Asturias, Spain
| | - José M Costa-Fernández
- Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, Avda. Julián Clavería 8, 33006 Oviedo, Asturias, Spain
| | - Ana Soldado
- Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, Avda. Julián Clavería 8, 33006 Oviedo, Asturias, Spain
| |
Collapse
|
4
|
Yin X, Zhao C, Zhao Y, Zhu Y. Parallel Monitoring of Glucose, Free Amino Acids, and Vitamin C in Fruits Using a High-Throughput Paper-Based Sensor Modified with Poly(carboxybetaine acrylamide). BIOSENSORS 2023; 13:1001. [PMID: 38131761 PMCID: PMC10741689 DOI: 10.3390/bios13121001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Revised: 11/18/2023] [Accepted: 11/20/2023] [Indexed: 12/23/2023]
Abstract
Herein, a cost-effective and portable microfluidic paper-based sensor is proposed for the simultaneous and rapid detection of glucose, free amino acids, and vitamin C in fruit. The device was constructed by embedding a poly(carboxybetaine acrylamide) (pCBAA)-modified cellulose paper chip within a hydrophobic acrylic plate. We successfully showcased the capabilities of a filter paper-based microfluidic sensor for the detection of fruit nutrients using three distinct colorimetric analyses. Within a single paper chip, we simultaneously detected glucose, free amino acids, and vitamin C in the vivid hues of cyan blue, purple, and Turnbull's blue, respectively, in three distinctive detection zones. Notably, we employed more stable silver nanoparticles for glucose detection, replacing the traditional peroxidase approach. The detection limits for glucose reached a low level of 0.049 mmol/L. Meanwhile, the detection limits for free amino acids and vitamin C were found to be 0.236 mmol/L and 0.125 mmol/L, respectively. The feasibility of the proposed sensor was validated in 13 different practical fruit samples using spectrophotometry. Cellulose paper utilizes capillary action to process trace fluids in tiny channels, and combined with pCBAA, which has superior hydrophilicity and anti-pollution properties, it greatly improves the sensitivity and practicality of paper-based sensors. Therefore, the paper-based colorimetric device is expected to provide technical support for the nutritional value assessment of fruits in the field of rapid detection.
Collapse
Affiliation(s)
- Xinru Yin
- College of Food Science and Technology, Shanghai Ocean University, Shanghai 201306, China; (X.Y.); (C.Z.)
| | - Cheng Zhao
- College of Food Science and Technology, Shanghai Ocean University, Shanghai 201306, China; (X.Y.); (C.Z.)
- Henan Railway Food Safety Management Engineering Technology Research Center, Zhengzhou Railway Vocational & Technical College, Zhengzhou 451460, China
| | - Yong Zhao
- College of Food Science and Technology, Shanghai Ocean University, Shanghai 201306, China; (X.Y.); (C.Z.)
| | - Yongheng Zhu
- College of Food Science and Technology, Shanghai Ocean University, Shanghai 201306, China; (X.Y.); (C.Z.)
| |
Collapse
|
5
|
Al-Jaf SH, Omer KM. Accuracy improvement via novel ratiometry design in distance-based microfluidic paper based analytical device: instrument-free point of care testing. RSC Adv 2023; 13:15704-15713. [PMID: 37228680 PMCID: PMC10204734 DOI: 10.1039/d3ra01601c] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2023] [Accepted: 05/18/2023] [Indexed: 05/27/2023] Open
Abstract
Developing accurate, precise, instrument-free, and point-of-need microfluidic paper-based devices is highly significant in clinical diagnosis and biomedical analysis. In the present work, a ratiometric distance-based microfluidic paper-based analytical device (R-DB-μPAD), along with a three-dimensional (3D) multifunctional connector (spacer), was designed to improve the accuracy and detection resolution analyses. Specifically, the novel R-DB-μPAD was used for the accurate and precise detection of ascorbic acid (AA) as a model analyte. In this design, two channels were fabricated as detection zones, with a 3D spacer located between the sampling and detection zones to improve the detection resolution by preventing the reagents mixing from overspreading between these zones. Two probes for AA were used: Fe3+ and 1,10-phenanthroline were deposited in the first channel, and oxidized 3,3',5,5'-tetramethylbenzidine (oxTMB) was added to the second channel. Accuracy improvement of this ratiometry-based design was achieved by enhancing the linearity range and reducing the volume dependency of the output signal. Moreover, the 3D connector improved the detection resolution by eliminating the systematic errors. Under the optimal conditions, the ratio of the distances of the color bands in the two channels was used to construct an analytical calibration curve in the range from 0.05 to 1.2 mM, with a limit of detection of 16 μM. The proposed R-DB-μPAD combined with the connector was successfully used for the detection of AA in orange juice and vitamin C tablets with satisfactory accuracy and precision. This work opens the door for multiplex analysis of various analytes in different matrices.
Collapse
Affiliation(s)
- Sabah H Al-Jaf
- Department of Chemistry, College of Science, University of Sulaimani 46002 Sulaimani City Kurdistan Region Iraq
- Department of Chemistry, College of Science, University of Garmian Darbandikhan Road 46021 Kalar City Sulaimaniyah Province Iraq
| | - Khalid M Omer
- Department of Chemistry, College of Science, University of Sulaimani 46002 Sulaimani City Kurdistan Region Iraq
- Center of Biomedical Analysis, Department of Chemistry, College of Science, University of Sulaimani 46002 Sulaimani City Kurdistan Region Iraq
| |
Collapse
|
6
|
Microfluidics in smart packaging of foods. Food Res Int 2022; 161:111873. [DOI: 10.1016/j.foodres.2022.111873] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2022] [Revised: 07/14/2022] [Accepted: 08/23/2022] [Indexed: 11/16/2022]
|
7
|
Luo H, Liu S, Shi L, Li Z, Bai Q, Du X, Wang L, Zha H, Li C. Paper-Based Fluidic Sensing Platforms for β-Adrenergic Agonist Residue Point-of-Care Testing. BIOSENSORS 2022; 12:bios12070518. [PMID: 35884321 PMCID: PMC9313176 DOI: 10.3390/bios12070518] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/18/2022] [Revised: 07/07/2022] [Accepted: 07/08/2022] [Indexed: 11/16/2022]
Abstract
The illegal use of β-adrenergic agonists during livestock growth poses a threat to public health; the long-term intake of this medication can cause serious physiological side effects and even death. Therefore, rapid detection methods for β-adrenergic agonist residues on-site are required. Traditional detection methods such as liquid chromatography have limitations in terms of expensive instruments and complex operations. In contrast, paper methods are low cost, ubiquitous, and portable, which has led to them becoming the preferred detection method in recent years. Various paper-based fluidic devices have been developed to detect β-adrenergic agonist residues, including lateral flow immunoassays (LFAs) and microfluidic paper-based analytical devices (μPADs). In this review, the application of LFAs for the detection of β-agonists is summarized comprehensively, focusing on the latest advances in novel labeling and detection strategies. The use of μPADs as an analytical platform has attracted interest over the past decade due to their unique advantages and application for detecting β-adrenergic agonists, which are introduced here. Vertical flow immunoassays are also discussed for their shorter assay time and stronger multiplexing capabilities compared with LFAs. Furthermore, the development direction and prospects for the commercialization of paper-based devices are considered, shedding light on the development of point-of-care testing devices for β-adrenergic agonist residue detection.
Collapse
Affiliation(s)
- Hongzhi Luo
- Department of Laboratory Medicine, The Third Affiliated Hospital of Zunyi Medical University (The First People’s Hospital of Zunyi), Zunyi 563002, China;
| | - Shan Liu
- Sichuan Provincial Key Laboratory for Human Disease Gene Study, Department of Medical Genetics, Department of Laboratory Medicine, Sichuan Academy of Medical Sciences & Sichuan Provincial People’s Hospital, University of Electronic Science and Technology, Chengdu 610072, China;
| | - Lina Shi
- School of Medicine, University of Electronic Science and Technology of China, Chengdu 610054, China;
| | - Zhu Li
- College of Medical Technology, Chengdu University of Traditional Chinese Medicine, Chengdu 610075, China;
| | - Qianwen Bai
- Sichuan Jinxin Women & Children Hospital, Chengdu 610066, China;
| | - Xiaoxin Du
- Office of Scientific Research & Development, University of Electronic Science and Technology, Chengdu 610054, China;
| | - Lijun Wang
- Department of Ophthalmology, The Third People’s Hospital of Chengdu, The Affiliated Hospital of Southwest Jiaotong University, Chengdu 610031, China
- Correspondence: (L.W.); (H.Z.); (C.L.)
| | - He Zha
- Department of Laboratory Medicine, The Third Affiliated Hospital of Zunyi Medical University (The First People’s Hospital of Zunyi), Zunyi 563002, China;
- Correspondence: (L.W.); (H.Z.); (C.L.)
| | - Chenzhong Li
- Department of Biochemistry and Molecular Biology, School of Medicine, Tulane University, New Orleans, LA 70112, USA
- Correspondence: (L.W.); (H.Z.); (C.L.)
| |
Collapse
|
8
|
Wang G, Huang S, He H, Cheng J, Zhang T, Fu Z, Zhang S, Zhou Y, Li H, Liu X. Fabrication of a "progress bar" colorimetric strip sensor array by dye-mixing method as a potential food freshness indicator. Food Chem 2022; 373:131434. [PMID: 34731803 DOI: 10.1016/j.foodchem.2021.131434] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2021] [Revised: 10/12/2021] [Accepted: 10/17/2021] [Indexed: 12/20/2022]
Abstract
Colorimetric sensing is a low-cost, intuitive method for monitoring the freshness of food. We prepared a colorimetric strip sensor array by mixing different amounts of bromophenol blue (BPB) and bromocresol green (BCG). As results of NH3 simulation, the array strip turned from yellow to blue, and the number of blue spots increased with the increasing NH3, like a progress bar. Although the actual color is quite different, the color-changing trend was consistent with the simulated model calculated by a computer. The progress bar results remained stable under three lighting conditions. Furthermore, in the Cod preservation experiment, the color-changing progress of the strip sensor array is consistent with the simulation and can indicate Cod freshness while providing more distinguish levels. Therefore, a "progress bar" indicator built by this strategy possess the potential of realizing nondestructive, more accurate, and commercially available food quality monitoring through the naked eye and smart equipment recognition.
Collapse
Affiliation(s)
- Guannan Wang
- School of Printing and Packaging, Wuhan University, Wuhan 430079, China
| | - Shaoyun Huang
- Department of Graphic Information Processing, Jingchu University of Technology, Jingmen 448000, China
| | - Hui He
- School of Printing and Packaging, Wuhan University, Wuhan 430079, China
| | - Jiawei Cheng
- School of Printing and Packaging, Wuhan University, Wuhan 430079, China
| | - Tao Zhang
- School of Printing and Packaging, Wuhan University, Wuhan 430079, China
| | - Zhiqiang Fu
- School of Printing and Packaging, Wuhan University, Wuhan 430079, China
| | - Shasha Zhang
- School of Printing and Packaging, Wuhan University, Wuhan 430079, China
| | - Yuzhi Zhou
- School of Printing and Packaging, Wuhan University, Wuhan 430079, China
| | - Houbin Li
- School of Printing and Packaging, Wuhan University, Wuhan 430079, China.
| | - Xinghai Liu
- School of Printing and Packaging, Wuhan University, Wuhan 430079, China.
| |
Collapse
|
9
|
Wang G, Cheng J, Ma J, Huang S, Zhang T, Li Y, Li H. Preparation and application of an olfactory visualization freshness sensor array based on microfluid paper‐based chip. J FOOD PROCESS PRES 2022. [DOI: 10.1111/jfpp.16530] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Guannan Wang
- School of Printing and Packaging Wuhan University Wuhan China
| | - Jiawei Cheng
- School of Printing and Packaging Wuhan University Wuhan China
| | - Jun Ma
- School of Printing and Packaging Wuhan University Wuhan China
| | - Shaoyun Huang
- Department of Graphic Information Processing Jingchu University of Technology Jingmen China
| | - Tao Zhang
- School of Printing and Packaging Wuhan University Wuhan China
| | - Yanwei Li
- School of Printing and Packaging Wuhan University Wuhan China
| | - Houbin Li
- School of Printing and Packaging Wuhan University Wuhan China
| |
Collapse
|
10
|
Guan T, Xu Z, Wang J, Liu Y, Shen X, Li X, Sun Y, Lei H. Multiplex optical bioassays for food safety analysis: Toward on-site detection. Compr Rev Food Sci Food Saf 2022; 21:1627-1656. [PMID: 35181985 DOI: 10.1111/1541-4337.12914] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2021] [Revised: 12/28/2021] [Accepted: 12/29/2021] [Indexed: 12/15/2022]
Abstract
Food safety analysis plays a significant role in controlling food contamination and supervision. In recent years, multiplex optical bioassays (MOBAs) have been widely applied to analyze multiple hazards due to their efficiency and low cost. However, due to the challenges such as multiplexing capacity, poor sensitivity, and bulky instrumentation, the further application of traditional MOBAs in food screening has been limited. In this review, effective strategies regarding food safety MOBAs are summarized, such as spatial-resolution modes performed in multi-T lines/dots strips or arrays of strip/microplate/microfluidic chip/SPR chip and signal-resolution modes employing distinguishable colorimetric/luminescence/fluorescence/surface plasma resonance/surface-enhanced Raman spectrum as signal tags. Following this, new trends on how to design engineered sensor architecture and exploit distinguishable signal reporters, how to improve both multiplexing capacity and sensitivity, and how to integrate these formats into smartphones so as to be mobile are summarized systematically. Typically, in the case of enhancing multiplexing capacity and detection throughput, microfluidic array chips with multichannel architecture would be a favorable approach to overcome the spatial and physical limitations of immunochromatographic assay (ICA) test strips. Moreover, noble metal nanoparticles and single-excitation, multiple-emission luminescence nanomaterials hold great potential in developing ultrasensitive MOBAs. Finally, the exploitation of innovative multiplexing strategy hybridized with powerful and widely available smartphones opens new perspectives to MOBAs. In future, the MOBAs should be more sensitive, have higher multiplexing capacity, and easier instrumentation.
Collapse
Affiliation(s)
- Tian Guan
- Guangdong Provincial Key Laboratory of Food Quality and Safety / Nation-Local Joint Engineering Research Center for Machining and Safety of Livestock and Poultry Products, College of Food Science, South China Agricultural University, Guangzhou, 510642, China
| | - Zhenlin Xu
- Guangdong Provincial Key Laboratory of Food Quality and Safety / Nation-Local Joint Engineering Research Center for Machining and Safety of Livestock and Poultry Products, College of Food Science, South China Agricultural University, Guangzhou, 510642, China.,Guangdong Laboratory for Lingnan Modern Agriculture, Guangzhou, China
| | - Jin Wang
- Guangdong Provincial Key Laboratory of Food Quality and Safety / Nation-Local Joint Engineering Research Center for Machining and Safety of Livestock and Poultry Products, College of Food Science, South China Agricultural University, Guangzhou, 510642, China
| | - Yingju Liu
- Department of Applied Chemistry, College of Materials and Energy, South China Agricultural University, Guangzhou, China
| | - Xing Shen
- Guangdong Provincial Key Laboratory of Food Quality and Safety / Nation-Local Joint Engineering Research Center for Machining and Safety of Livestock and Poultry Products, College of Food Science, South China Agricultural University, Guangzhou, 510642, China
| | - Xiangmei Li
- Guangdong Provincial Key Laboratory of Food Quality and Safety / Nation-Local Joint Engineering Research Center for Machining and Safety of Livestock and Poultry Products, College of Food Science, South China Agricultural University, Guangzhou, 510642, China
| | - Yuanming Sun
- Guangdong Provincial Key Laboratory of Food Quality and Safety / Nation-Local Joint Engineering Research Center for Machining and Safety of Livestock and Poultry Products, College of Food Science, South China Agricultural University, Guangzhou, 510642, China
| | - Hongtao Lei
- Guangdong Provincial Key Laboratory of Food Quality and Safety / Nation-Local Joint Engineering Research Center for Machining and Safety of Livestock and Poultry Products, College of Food Science, South China Agricultural University, Guangzhou, 510642, China.,Guangdong Laboratory for Lingnan Modern Agriculture, Guangzhou, China
| |
Collapse
|
11
|
Komatsu T, Maeda R, Maeki M, Ishida A, Tani H, Tokeshi M. Dip-Type Paper-Based Analytical Device for Straightforward Quantitative Detection without Precise Sample Introduction. ACS Sens 2021; 6:1094-1102. [PMID: 33660502 DOI: 10.1021/acssensors.0c02367] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The development of low-cost, user-friendly paper-based analytical devices (PADs) that can easily measure target chemicals is attracting attention. However, most PADs require manipulation of the sample using sophisticated micropipettes for quantitative analyses, which restricts their user-friendliness. In addition, immobilization of detection molecules to cellulose fibers is essential for achieving good measuring ability as it ensures the homogeneity of color development. Here, we have described a dip-type PAD that does not require pipette manipulation for sample introduction and immobilization of detection molecules to cellulose fibers and its application to ascorbic acid (AA) and pH assays. The PAD consisted of a dipping area and two channels, each with two detection zones. The developed PADs show color distribution in the two detection zones depending on the sample flow from the dipping area. In comparison with a PAD that has one detection zone at the end of the channel, our developed device achieved higher sensitivity (limit of detection (LOD), 0.22 mg/mL) and reproducibility (maximum coefficient of variation (CV), 2.4%) in AA detection. However, in pH detection, the reproducibility of the PAD with one detection zone at the end of the channel (maximum CV, 21%) was worse than that with two zones (maximum CV, 11%). Furthermore, a dipping time over 3 s did not affect color formation or calibration curves in AA detection: LODs at 3 and 30 s dipping time were 18 and 5.8 μg/mL, respectively. The simultaneous determination of AA and pH in various beverages was performed with no significant difference compared to results of the conventional method.
Collapse
Affiliation(s)
- Takeshi Komatsu
- Graduate School of Chemical Sciences and Engineering, Hokkaido University, Kita 13 Nishi 8, Sapporo 060-8628, Japan
| | - Ryoga Maeda
- Graduate School of Chemical Sciences and Engineering, Hokkaido University, Kita 13 Nishi 8, Sapporo 060-8628, Japan
| | - Masatoshi Maeki
- Division of Applied Chemistry, Faculty of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita, Sapporo 060-8628, Japan
| | - Akihiko Ishida
- Division of Applied Chemistry, Faculty of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita, Sapporo 060-8628, Japan
| | - Hirofumi Tani
- Division of Applied Chemistry, Faculty of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita, Sapporo 060-8628, Japan
| | - Manabu Tokeshi
- Division of Applied Chemistry, Faculty of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita, Sapporo 060-8628, Japan
- Innovative Research Centre for Preventive Medical Engineering, Nagoya University, Furo-cho, Chikusa, Nagoya 464-8601, Japan
- Institute of Nano-Life-Systems, Institute of Innovation for Future Society, Nagoya University, Furo-cho,
Chikusa, Nagoya 464-8601, Japan
| |
Collapse
|
12
|
Dabbagh SR, Becher E, Ghaderinezhad F, Havlucu H, Ozcan O, Ozkan M, Yetisen AK, Tasoglu S. Increasing the packing density of assays in paper-based microfluidic devices. BIOMICROFLUIDICS 2021; 15:011502. [PMID: 33569089 PMCID: PMC7864678 DOI: 10.1063/5.0042816] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2021] [Accepted: 01/07/2021] [Indexed: 05/04/2023]
Abstract
Paper-based devices have a wide range of applications in point-of-care diagnostics, environmental analysis, and food monitoring. Paper-based devices can be deployed to resource-limited countries and remote settings in developed countries. Paper-based point-of-care devices can provide access to diagnostic assays without significant user training to perform the tests accurately and timely. The market penetration of paper-based assays requires decreased device fabrication costs, including larger packing density of assays (i.e., closely packed features) and minimization of assay reagents. In this review, we discuss fabrication methods that allow for increasing packing density and generating closely packed features in paper-based devices. To ensure that the paper-based device is low-cost, advanced fabrication methods have been developed for the mass production of closely packed assays. These emerging methods will enable minimizing the volume of required samples (e.g., liquid biopsies) and reagents in paper-based microfluidic devices.
Collapse
Affiliation(s)
| | - Elaina Becher
- Department of Biomedical Engineering, University of Connecticut, Storrs, Connecticut 06269, USA
| | - Fariba Ghaderinezhad
- Department of Mechanical Engineering, University of Connecticut, Storrs, Connecticut 06269, USA
| | - Hayati Havlucu
- Koç University Arçelik Research Center for Creative Industries (KUAR), Koç University, Sariyer, Istanbul 34450, Turkey
| | - Oguzhan Ozcan
- Koç University Arçelik Research Center for Creative Industries (KUAR), Koç University, Sariyer, Istanbul 34450, Turkey
| | - Mehmed Ozkan
- Boğaziçi Institute of Biomedical Engineering, Boğaziçi University, Çengelköy, Istanbul 34684, Turkey
| | - Ali Kemal Yetisen
- Department of Chemical Engineering, Imperial College London, London SW7 2AZ, United Kingdom
| | | |
Collapse
|
13
|
Boobphahom S, Nguyet Ly M, Soum V, Pyun N, Kwon OS, Rodthongkum N, Shin K. Recent Advances in Microfluidic Paper-Based Analytical Devices toward High-Throughput Screening. Molecules 2020; 25:E2970. [PMID: 32605281 PMCID: PMC7412548 DOI: 10.3390/molecules25132970] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Revised: 06/17/2020] [Accepted: 06/19/2020] [Indexed: 02/06/2023] Open
Abstract
Microfluidic paper-based analytical devices (µPADs) have become promising tools offering various analytical applications for chemical and biological assays at the point-of-care (POC). Compared to traditional microfluidic devices, µPADs offer notable advantages; they are cost-effective, easily fabricated, disposable, and portable. Because of our better understanding and advanced engineering of µPADs, multistep assays, high detection sensitivity, and rapid result readout have become possible, and recently developed µPADs have gained extensive interest in parallel analyses to detect biomarkers of interest. In this review, we focus on recent developments in order to achieve µPADs with high-throughput capability. We discuss existing fabrication techniques and designs, and we introduce and discuss current detection methods and their applications to multiplexed detection assays in relation to clinical diagnosis, drug analysis and screening, environmental monitoring, and food and beverage quality control. A summary with future perspectives for µPADs is also presented.
Collapse
Affiliation(s)
- Siraprapa Boobphahom
- Metallurgy and Materials Science Research Institute, Chulalongkorn University, Soi Chula 12, Phayathai Road, Pathumwan, Bangkok 10330, Thailand;
| | - Mai Nguyet Ly
- Department of Chemistry and Institute of Biological Interfaces, Sogang University, Seoul 04107, Korea; (M.N.L.); (V.S.); (N.P.); (O.-S.K.)
| | - Veasna Soum
- Department of Chemistry and Institute of Biological Interfaces, Sogang University, Seoul 04107, Korea; (M.N.L.); (V.S.); (N.P.); (O.-S.K.)
| | - Nayoon Pyun
- Department of Chemistry and Institute of Biological Interfaces, Sogang University, Seoul 04107, Korea; (M.N.L.); (V.S.); (N.P.); (O.-S.K.)
| | - Oh-Sun Kwon
- Department of Chemistry and Institute of Biological Interfaces, Sogang University, Seoul 04107, Korea; (M.N.L.); (V.S.); (N.P.); (O.-S.K.)
| | - Nadnudda Rodthongkum
- Metallurgy and Materials Science Research Institute, Chulalongkorn University, Soi Chula 12, Phayathai Road, Pathumwan, Bangkok 10330, Thailand;
| | - Kwanwoo Shin
- Department of Chemistry and Institute of Biological Interfaces, Sogang University, Seoul 04107, Korea; (M.N.L.); (V.S.); (N.P.); (O.-S.K.)
| |
Collapse
|