1
|
Chen YY, Chang CJ, Liang YW, Tseng HY, Li SJ, Chang CW, Wu YT, Shao HH, Chen PC, Lai ML, Deng WC, Hsu R, Lo YC. Utilizing diffusion tensor imaging as an image biomarker in exploring the therapeutic efficacy of forniceal deep brain stimulation in a mice model of Alzheimer's disease. J Neural Eng 2024; 21:056003. [PMID: 39230033 DOI: 10.1088/1741-2552/ad7322] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Accepted: 08/15/2024] [Indexed: 09/05/2024]
Abstract
Objective.With prolonged life expectancy, the incidence of memory deficits, especially in Alzheimer's disease (AD), has increased. Although multiple treatments have been evaluated, no promising treatment has been found to date. Deep brain stimulation (DBS) of the fornix area was explored as a possible treatment because the fornix is intimately connected to memory-related areas that are vulnerable in AD; however, a proper imaging biomarker for assessing the therapeutic efficiency of forniceal DBS in AD has not been established.Approach.This study assessed the efficacy and safety of DBS by estimating the optimal intersection volume between the volume of tissue activated and the fornix. Utilizing a gold-electroplating process, the microelectrode's surface area on the neural probe was increased, enhancing charge transfer performance within potential water window limits. Bilateral fornix implantation was conducted in triple-transgenic AD mice (3 × Tg-AD) and wild-type mice (strain: B6129SF1/J), with forniceal DBS administered exclusively to 3 × Tg-AD mice in the DBS-on group. Behavioral tasks, diffusion tensor imaging (DTI), and immunohistochemistry (IHC) were performed in all mice to assess the therapeutic efficacy of forniceal DBS.Main results.The results illustrated that memory deficits and increased anxiety-like behavior in 3 × Tg-AD mice were rescued by forniceal DBS. Furthermore, forniceal DBS positively altered DTI indices, such as increasing fractional anisotropy (FA) and decreasing mean diffusivity (MD), together with reducing microglial cell and astrocyte counts, suggesting a potential causal relationship between revised FA/MD and reduced cell counts in the anterior cingulate cortex, hippocampus, fornix, amygdala, and entorhinal cortex of 3 × Tg-AD mice following forniceal DBS.Significance.The efficacy of forniceal DBS in AD can be indicated by alterations in DTI-based biomarkers reflecting the decreased activation of glial cells, suggesting reduced neural inflammation as evidenced by improvements in memory and anxiety-like behavior.
Collapse
Affiliation(s)
- You-Yin Chen
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, No.155, Sec.2, Linong St., Taipei 11221, Taiwan, Republic of China
- Ph.D. Program in Medical Neuroscience, College of Medical Science and Technology, Taipei Medical University, 12F., Education & Research Building, Shuang-Ho Campus, No. 301, Yuantong Rd., New Taipei City 23564, Taiwan, Republic of China
| | - Chih-Ju Chang
- Department of Neurosurgery, Cathay General Hospital, No. 280, Sec. 4, Renai Rd., Taipei 10629, Taiwan, Republic of China
- School of Medicine, Fu Jen Catholic University, No.510, Zhongzheng Rd., New Taipei City 242062, Taiwan, Republic of China
| | - Yao-Wen Liang
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, No.155, Sec.2, Linong St., Taipei 11221, Taiwan, Republic of China
| | - Hsin-Yi Tseng
- Ph.D. Program in Medical Neuroscience, College of Medical Science and Technology, Taipei Medical University and National Health Research Institutes, 12F., Education & Research Building, Shuang-Ho Campus, No. 301, Yuantong Rd., New Taipei City 23564, Taiwan, Republic of China
| | - Ssu-Ju Li
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, No.155, Sec.2, Linong St., Taipei 11221, Taiwan, Republic of China
| | - Ching-Wen Chang
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, No.155, Sec.2, Linong St., Taipei 11221, Taiwan, Republic of China
| | - Yen-Ting Wu
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, No.155, Sec.2, Linong St., Taipei 11221, Taiwan, Republic of China
| | - Huai-Hsuan Shao
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, No.155, Sec.2, Linong St., Taipei 11221, Taiwan, Republic of China
| | - Po-Chun Chen
- Department of Materials and Mineral Resources Engineering, National Taipei University of Technology, No. 1, Sec. 3, Zhongxiao E. Rd., Taipei 10608, Taiwan, Republic of China
| | - Ming-Liang Lai
- Graduate Institute of Intellectual Property, National Taipei University of Technology, No. 1, Sec. 3, Zhongxiao E. Rd., Taipei 10608, Taiwan, Republic of China
| | - Wen-Chun Deng
- Departments of Neurosurgery, Keelung Chang Gung Memorial Hospital, Chang Gung University, No.222, Maijin Rd., Keelung 20400, Taiwan, Republic of China
| | - RuSiou Hsu
- Department of Ophthalmology, Stanford University, 1651 Page Mill Rd., Palo Alto, CA 94304, United States of America
| | - Yu-Chun Lo
- Ph.D. Program in Medical Neuroscience, College of Medical Science and Technology, Taipei Medical University, 12F., Education & Research Building, Shuang-Ho Campus, No. 301, Yuantong Rd., New Taipei City 23564, Taiwan, Republic of China
| |
Collapse
|
2
|
Park R, Lee DH, Koh CS, Kwon YW, Chae SY, Kim C, Jung HH, Jeong J, Hong SW. Laser-Assisted Structuring of Graphene Films with Biocompatible Liquid Crystal Polymer for Skin/Brain-Interfaced Electrodes. Adv Healthc Mater 2024; 13:e2301753. [PMID: 37820714 PMCID: PMC11468237 DOI: 10.1002/adhm.202301753] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Revised: 10/09/2023] [Indexed: 10/13/2023]
Abstract
The work presented here introduces a facile strategy for the development of flexible and stretchable electrodes that harness the robust characteristics of carbon nanomaterials through laser processing techniques on a liquid crystal polymer (LCP) film. By utilizing LCP film as a biocompatible electronic substrate, control is demonstrated over the laser irradiation parameters to achieve efficient pattern generation and transfer printing processes, thereby yielding highly conductive laser-induced graphene (LIG) bioelectrodes. To enhance the resolution of the patterned LIG film, shadow masks are employed during laser scanning on the LCP film surface. This approach is compatible with surface-mounted device integration, enabling the circuit writing of LIG/LCP materials in a flexible format. Moreover, kirigami-inspired on-skin bioelectrodes are introduced that exhibit reasonable stretchability, enabling independent connections to healthcare hardware platforms for electrocardiogram (ECG) and electromyography (EMG) measurements. Additionally, a brain-interfaced LIG microelectrode array is proposed that combines mechanically compliant architectures with LCP encapsulation for stimulation and recording purposes, leveraging their advantageous structural features and superior electrochemical properties. This developed approach offers a cost-effective and scalable route for producing patterned arrays of laser-converted graphene as bioelectrodes. These bioelectrodes serve as ideal circuit-enabled flexible substrates with long-term reliability in the ionic environment of the human body.
Collapse
Affiliation(s)
- Rowoon Park
- Department of Optics and Mechatronics Engineering, Department of Cogno‐Mechatronics Engineering, College of Nanoscience and NanotechnologyPusan National UniversityBusan46241Republic of Korea
| | - Dong Hyeon Lee
- School of Mechanical EngineeringPusan National UniversityBusan46241Republic of Korea
| | - Chin Su Koh
- Department of NeurosurgeryCollege of MedicineYonsei UniversitySeoul03722Republic of Korea
| | - Young Woo Kwon
- Engineering Research Center for Color‐Modulated Extra‐Sensory Perception TechnologyPusan National UniversityBusan46241Republic of Korea
| | - Seon Yeong Chae
- Engineering Research Center for Color‐Modulated Extra‐Sensory Perception TechnologyPusan National UniversityBusan46241Republic of Korea
| | - Chang‐Seok Kim
- Department of Optics and Mechatronics Engineering, Department of Cogno‐Mechatronics Engineering, College of Nanoscience and NanotechnologyPusan National UniversityBusan46241Republic of Korea
- Engineering Research Center for Color‐Modulated Extra‐Sensory Perception TechnologyPusan National UniversityBusan46241Republic of Korea
| | - Hyun Ho Jung
- Department of NeurosurgeryCollege of MedicineYonsei UniversitySeoul03722Republic of Korea
| | - Joonsoo Jeong
- School of Biomedical Convergence EngineeringDepartment of Information Convergence EngineeringPusan National UniversityYangsan50612Republic of Korea
| | - Suck Won Hong
- Department of Optics and Mechatronics Engineering, Department of Cogno‐Mechatronics Engineering, College of Nanoscience and NanotechnologyPusan National UniversityBusan46241Republic of Korea
- Engineering Research Center for Color‐Modulated Extra‐Sensory Perception TechnologyPusan National UniversityBusan46241Republic of Korea
| |
Collapse
|
3
|
Popa RC, Serban CA, Barborica A, Zagrean AM, Buiu O, Dumbravescu N, Paslaru AC, Obreja C, Pachiu C, Stoian M, Marculescu C, Radoi A, Vulpe S, Ion M. Functional Enhancement and Characterization of an Electrophysiological Mapping Electrode Probe with Carbonic, Directional Macrocontacts. SENSORS (BASEL, SWITZERLAND) 2023; 23:7497. [PMID: 37687953 PMCID: PMC10490806 DOI: 10.3390/s23177497] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Revised: 08/16/2023] [Accepted: 08/21/2023] [Indexed: 09/10/2023]
Abstract
Electrophysiological mapping (EM) using acute electrode probes is a common procedure performed during functional neurosurgery. Due to their constructive specificities, the EM probes are lagging in innovative enhancements. This work addressed complementing a clinically employed EM probe with carbonic and circumferentially segmented macrocontacts that are operable both for neurophysiological sensing ("recording") of local field potentials (LFP) and for test stimulation. This paper illustrates in-depth the development that is based on the direct writing of functional materials. The unconventional fabrication processes were optimized on planar geometry and then transferred to the cylindrically thin probe body. We report and discuss the constructive concept and architecture of the probe, characteristics of the electrochemical interface deduced from voltammetry and chronopotentiometry, and the results of in vitro and in vivo recording and pulse stimulation tests. Two- and three-directional macrocontacts were added on probes having shanks of 550 and 770 μm diameters and 10-23 cm lengths. The graphitic material presents a ~2.7 V wide, almost symmetric water electrolysis window, and an ultra-capacitive charge transfer. When tested with clinically relevant 150 μs biphasic current pulses, the interfacial polarization stayed safely away from the water window for pulse amplitudes up to 9 mA (135 μC/cm2). The in vivo experiments on adult rat models confirmed the high-quality sensing of LFPs. Additionally, the in vivo-prevailing increase in the electrode impedance and overpotential are discussed and modeled by an ionic mobility-reducing spongiform structure; this restricted diffusion model gives new applicative insight into the in vivo-uprisen stimulation overpotential.
Collapse
Affiliation(s)
- Radu C. Popa
- National Institute for R&D in Microtechnologies–IMT Bucharest, 077190 Bucharest, Romania; (O.B.); (N.D.); (C.O.); (C.P.); (M.S.); (C.M.); (A.R.); (S.V.); (M.I.)
| | - Cosmin-Andrei Serban
- Termobit Prod Srl, 020281 Bucharest, Romania; (C.-A.S.); (A.B.)
- Fhc, Inc., Bowdoin, ME 04287, USA
- Faculty of Physics, University of Bucharest, 077125 Magurele, Romania
| | - Andrei Barborica
- Termobit Prod Srl, 020281 Bucharest, Romania; (C.-A.S.); (A.B.)
- Fhc, Inc., Bowdoin, ME 04287, USA
- Faculty of Physics, University of Bucharest, 077125 Magurele, Romania
| | - Ana-Maria Zagrean
- Physiology and Neuroscience Department, “Carol Davila” University of Medicine and Pharmacy, 050474 Bucharest, Romania; (A.-M.Z.); (A.-C.P.)
| | - Octavian Buiu
- National Institute for R&D in Microtechnologies–IMT Bucharest, 077190 Bucharest, Romania; (O.B.); (N.D.); (C.O.); (C.P.); (M.S.); (C.M.); (A.R.); (S.V.); (M.I.)
| | - Niculae Dumbravescu
- National Institute for R&D in Microtechnologies–IMT Bucharest, 077190 Bucharest, Romania; (O.B.); (N.D.); (C.O.); (C.P.); (M.S.); (C.M.); (A.R.); (S.V.); (M.I.)
| | - Alexandru-Catalin Paslaru
- Physiology and Neuroscience Department, “Carol Davila” University of Medicine and Pharmacy, 050474 Bucharest, Romania; (A.-M.Z.); (A.-C.P.)
| | - Cosmin Obreja
- National Institute for R&D in Microtechnologies–IMT Bucharest, 077190 Bucharest, Romania; (O.B.); (N.D.); (C.O.); (C.P.); (M.S.); (C.M.); (A.R.); (S.V.); (M.I.)
| | - Cristina Pachiu
- National Institute for R&D in Microtechnologies–IMT Bucharest, 077190 Bucharest, Romania; (O.B.); (N.D.); (C.O.); (C.P.); (M.S.); (C.M.); (A.R.); (S.V.); (M.I.)
| | - Marius Stoian
- National Institute for R&D in Microtechnologies–IMT Bucharest, 077190 Bucharest, Romania; (O.B.); (N.D.); (C.O.); (C.P.); (M.S.); (C.M.); (A.R.); (S.V.); (M.I.)
| | - Catalin Marculescu
- National Institute for R&D in Microtechnologies–IMT Bucharest, 077190 Bucharest, Romania; (O.B.); (N.D.); (C.O.); (C.P.); (M.S.); (C.M.); (A.R.); (S.V.); (M.I.)
| | - Antonio Radoi
- National Institute for R&D in Microtechnologies–IMT Bucharest, 077190 Bucharest, Romania; (O.B.); (N.D.); (C.O.); (C.P.); (M.S.); (C.M.); (A.R.); (S.V.); (M.I.)
| | - Silviu Vulpe
- National Institute for R&D in Microtechnologies–IMT Bucharest, 077190 Bucharest, Romania; (O.B.); (N.D.); (C.O.); (C.P.); (M.S.); (C.M.); (A.R.); (S.V.); (M.I.)
| | - Marian Ion
- National Institute for R&D in Microtechnologies–IMT Bucharest, 077190 Bucharest, Romania; (O.B.); (N.D.); (C.O.); (C.P.); (M.S.); (C.M.); (A.R.); (S.V.); (M.I.)
| |
Collapse
|
4
|
Ruhunage C, Dhawan V, Nawarathne CP, Hoque A, Cui XT, Alvarez NT. Evaluation of Polymer-Coated Carbon Nanotube Flexible Microelectrodes for Biomedical Applications. Bioengineering (Basel) 2023; 10:647. [PMID: 37370578 PMCID: PMC10295676 DOI: 10.3390/bioengineering10060647] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Revised: 05/19/2023] [Accepted: 05/24/2023] [Indexed: 06/29/2023] Open
Abstract
The demand for electrically insulated microwires and microfibers in biomedical applications is rapidly increasing. Polymer protective coatings with high electrical resistivity, good chemical resistance, and a long shelf-life are critical to ensure continuous device operation during chronic applications. As soft and flexible electrodes can minimize mechanical mismatch between tissues and electronics, designs based on flexible conductive microfibers, such as carbon nanotube (CNT) fibers, and soft polymer insulation have been proposed. In this study, a continuous dip-coating approach was adopted to insulate meters-long CNT fibers with hydrogenated nitrile butadiene rubber (HNBR), a soft and rubbery insulating polymer. Using this method, 4.8 m long CNT fibers with diameters of 25-66 µm were continuously coated with HNBR without defects or interruptions. The coated CNT fibers were found to be uniform, pinhole free, and biocompatible. Furthermore, the HNBR coating had better high-temperature tolerance than conventional insulating materials. Microelectrodes prepared using the HNBR-coated CNT fibers exhibited stable electrochemical properties, with a specific impedance of 27.0 ± 9.4 MΩ µm2 at 1.0 kHz and a cathodal charge storage capacity of 487.6 ± 49.8 mC cm-2. Thus, the developed electrodes express characteristics that made them suitable for use in implantable medical devices for chronic in vivo applications.
Collapse
Affiliation(s)
- Chethani Ruhunage
- Department of Chemistry, University of Cincinnati, Cincinnati, OH 45221, USA; (C.R.); (C.P.N.); (A.H.)
| | - Vaishnavi Dhawan
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15261, USA;
| | - Chaminda P. Nawarathne
- Department of Chemistry, University of Cincinnati, Cincinnati, OH 45221, USA; (C.R.); (C.P.N.); (A.H.)
| | - Abdul Hoque
- Department of Chemistry, University of Cincinnati, Cincinnati, OH 45221, USA; (C.R.); (C.P.N.); (A.H.)
| | - Xinyan Tracy Cui
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15261, USA;
| | - Noe T. Alvarez
- Department of Chemistry, University of Cincinnati, Cincinnati, OH 45221, USA; (C.R.); (C.P.N.); (A.H.)
| |
Collapse
|
5
|
Puglia MK, Bowen PK. Cyclic Voltammetry Study of Noble Metals and Their Alloys for Use in Implantable Electrodes. ACS OMEGA 2022; 7:34200-34212. [PMID: 36188288 PMCID: PMC9520554 DOI: 10.1021/acsomega.2c03563] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Accepted: 08/30/2022] [Indexed: 06/16/2023]
Abstract
Innovation in the application and miniaturization of implantable electrodes has caused a spike in new electrode material research; however, few robust studies are available that compare different metal electrodes in biologically relevant media. Herein, cyclic voltammetry has been employed to compare platinum, palladium, and gold-based electrodes' potentiometric scans and their corresponding charge storage capacities (CSCs). Ten different noble metals and alloys in these families were tested under pseudophysiological conditions in phosphate-buffered saline (pH 7.4) at 37 °C. Charge storage capacity values (mC/cm2) were calculated for the oxide reduction, hydrogen adsorption, hydrogen desorption, and oxide formation peaks. Five scan rates spanning 2 orders of magnitude (10, 50, 100, 500, and 1000 mV/s) in both sparged and aerated environments were evaluated. Materials have been ranked by their charge storage capacities, reversibility, and trends discussed. Palladium-based alloys outperformed platinum-based alloys in the sparged condition and were ranked equally as high in the aerated condition. The Paliney 1100 (Pd-Re) alloy gave the highest observed calculated CSC value of 0.64 ± 0.02 mC/cm2 in the aerated condition, demonstrating 73 ± 5% reversibility. Trends between metal electrode families elicited in this study can afford valuable insight into future engineering of high performing implantable electrode materials.
Collapse
|
6
|
Schweigmann M, Kirchhoff F, Koch KP. Comparative study of platinum electroplating to improve micro gold electrode arrays with LCP laminate. BIOMED ENG-BIOMED TE 2022; 67:33-42. [PMID: 35007412 DOI: 10.1515/bmt-2021-0020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Accepted: 12/17/2021] [Indexed: 11/15/2022]
Abstract
Decoding the cellular network interaction of neurons and glial cells are important in the development of new therapies for diseases of the central nervous system (CNS). Electrophysiological in vivo studies in mice will help to understand the highly complex network. In this paper, the optimization of epidural liquid crystal polymer (LCP) electrodes for different platinum electroplating parameters are presented and compared. Constant current and pulsed current electroplating varied in strength and duration was used to decrease the electrode impedance and to increase the charge storage capacity (CSCC). In best cases, both methods generated similar results with an impedance reduction of about 99%. However, electroplating with pulsed currents was less parameter-dependent than the electroplating with constant current. The use of ultrasound was essential to generate platinum coatings without plating defects. Electrode model parameters extracted from the electrode impedance reflected the increase in surface porosity due to the electroplating processes.
Collapse
Affiliation(s)
- Michael Schweigmann
- Department of Electrical Engineering, Trier University of Applied Sciences, Trier, Germany.,Department of Molecular Physiology, Center for Integrative Physiology and Molecular Medicine, University of the Saarland, Homburg, Germany
| | - Frank Kirchhoff
- Department of Molecular Physiology, Center for Integrative Physiology and Molecular Medicine, University of the Saarland, Homburg, Germany
| | - Klaus P Koch
- Department of Electrical Engineering, Trier University of Applied Sciences, Trier, Germany
| |
Collapse
|
7
|
Zheng XS, Tan C, Castagnola E, Cui XT. Electrode Materials for Chronic Electrical Microstimulation. Adv Healthc Mater 2021; 10:e2100119. [PMID: 34029008 PMCID: PMC8257249 DOI: 10.1002/adhm.202100119] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Revised: 04/20/2021] [Indexed: 02/06/2023]
Abstract
Electrical microstimulation has enabled partial restoration of vision, hearing, movement, somatosensation, as well as improving organ functions by electrically modulating neural activities. However, chronic microstimulation is faced with numerous challenges. The implantation of an electrode array into the neural tissue triggers an inflammatory response, which can be exacerbated by the delivery of electrical currents. Meanwhile, prolonged stimulation may lead to electrode material degradation., which can be accelerated by the hostile inflammatory environment. Both material degradation and adverse tissue reactions can compromise stimulation performance over time. For stable chronic electrical stimulation, an ideal microelectrode must present 1) high charge injection limit, to efficiently deliver charge without exceeding safety limits for both tissue and electrodes, 2) small size, to gain high spatial selectivity, 3) excellent biocompatibility that ensures tissue health immediately next to the device, and 4) stable in vivo electrochemical properties over the application period. In this review, the challenges in chronic microstimulation are described in detail. To aid material scientists interested in neural stimulation research, the in vitro and in vivo testing methods are introduced for assessing stimulation functionality and longevity and a detailed overview of recent advances in electrode material research and device fabrication for improving chronic microstimulation performance is provided.
Collapse
Affiliation(s)
- Xin Sally Zheng
- Department of Bioengineering, University of Pittsburgh, 3501 Fifth Ave. Pittsburgh, Pittsburgh, PA, 15213, USA
| | - Chao Tan
- Department of Bioengineering, University of Pittsburgh, 3501 Fifth Ave. Pittsburgh, Pittsburgh, PA, 15213, USA
| | - Elisa Castagnola
- Department of Bioengineering, University of Pittsburgh, 3501 Fifth Ave. Pittsburgh, Pittsburgh, PA, 15213, USA
| | - Xinyan Tracy Cui
- Department of Bioengineering, University of Pittsburgh, 3501 Fifth Ave. Pittsburgh, Pittsburgh, PA, 15213, USA
| |
Collapse
|
8
|
Shah AR, Khan MS, Hirahara AM, Lange M, Ranjan R, Dosdall DJ. In Vitro/Ex Vivo Investigation of Modified Utah Electrode Array to Selectively Sense and Pace the Sub-Surface Cardiac His Bundle. ACS Biomater Sci Eng 2020; 6:3335-3348. [PMID: 32715084 DOI: 10.1021/acsbiomaterials.0c00065] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Utah Electrode Arrays (UEAs) have previously been characterized and implanted for neural recordings and stimulation at relatively low current levels. This proof-of-concept study investigated the applicability of UEAs in sub-surface cardiac pacing, for the first time, particularly to selectively sense and pace the His-Bundle (HB). HB pacing produces synchronous ventricular depolarization and improved cardiac function. Modified UEAs with sputtered iridium oxide film (SIROF) tips (100 - 150 μm) were characterized for SIROF delamination using an electrochemical impedance spectroscopy (EIS), scanning electron microscopy (SEM), and voltage transient (VT) techniques at various current levels of up to 8 mA for a biphasic pulse with 1 ms duration per phase at 4 Hz. Our results indicate that at a short pacing duration of 20 s with current levels of up to 4 mA, the SIROF exhibited a strong charge-transfer performance. For the longer pacing duration (6 min), SIROF demonstrated its holding capacity at all current levels except for ≥2 mA when delamination commenced for the time exceeded 4 min (EIS) and 2 min (VT). UEAs were inserted in isolated, perfused goat hearts to record the HB electrograms in real-time. Both stimulated and unstimulated electrodes were characterized for SIROF delamination before, during and after in vivo work. Our findings indicate that UEA was stable during the heart's contraction and relaxation phase. Further, at a short pacing duration with current levels of up to 4 mA, UEA demonstrated high selectively in sensing the HB. This proof-of-concept work demonstrates the potential applicability of UEAs in cardiac applications.
Collapse
Affiliation(s)
- Ankur R Shah
- Department of Biomedical Engineering, The University of Utah, Salt Lake City, UT 84112, USA.,Nora Eccles Harrison Cardiovascular Research and Training Institute, The University of Utah, Salt Lake City, UT 84112, USA
| | - Muhammad S Khan
- Nora Eccles Harrison Cardiovascular Research and Training Institute, The University of Utah, Salt Lake City, UT 84112, USA
| | - Annie M Hirahara
- Department of Biomedical Engineering, The University of Utah, Salt Lake City, UT 84112, USA.,Nora Eccles Harrison Cardiovascular Research and Training Institute, The University of Utah, Salt Lake City, UT 84112, USA
| | - Matthias Lange
- Nora Eccles Harrison Cardiovascular Research and Training Institute, The University of Utah, Salt Lake City, UT 84112, USA
| | - Ravi Ranjan
- Department of Biomedical Engineering, The University of Utah, Salt Lake City, UT 84112, USA.,Nora Eccles Harrison Cardiovascular Research and Training Institute, The University of Utah, Salt Lake City, UT 84112, USA.,Division of Cardiovascular Medicine, Department of Internal Medicine, The University of Utah, Salt Lake City, UT 84112, USA
| | - Derek J Dosdall
- Department of Biomedical Engineering, The University of Utah, Salt Lake City, UT 84112, USA.,Nora Eccles Harrison Cardiovascular Research and Training Institute, The University of Utah, Salt Lake City, UT 84112, USA.,Division of Cardiovascular Medicine, Department of Internal Medicine, The University of Utah, Salt Lake City, UT 84112, USA.,Division of Cardiothoracic Surgery, Department of Surgery, The University of Utah, Salt Lake City, UT 84112, USA
| |
Collapse
|