1
|
Kirimi MT, Hoare D, Holsgrove M, Czyzewski J, Mirzai N, Mercer JR, Neale SL. Detection of Blood Clots Using a Whole Stent as an Active Implantable Biosensor. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2304748. [PMID: 38342628 DOI: 10.1002/advs.202304748] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Revised: 09/28/2023] [Indexed: 02/13/2024]
Abstract
Many cardiovascular problems stem from blockages that form within the vasculature and often treatment includes fitting a stent through percutaneous coronary intervention. This offers a minimally invasive therapy but re-occlusion through restenosis or thrombosis formation often occurs post-deployment. Research is ongoing into the creation of smart stents that can detect the occurrence of further problems. In this study, it is shown that selectively metalizing a non-conductive stent can create a set of electrodes that are capable of detecting a build-up of material around the stent. The associated increase in electrical impedance across the electrodes is measured, testing the stent with blood clot to mimic thrombosis. It is shown that the device is capable of sensing different amounts of occlusion. The stent can reproducibly sense the presence of clot showing a 16% +/-3% increase in impedance which is sufficient to reliably detect the clot when surrounded by explanted aorta (one sample t-test, p = 0.009, n = 9). It is demonstrated that this approach can be extended beyond the 3D printed prototypes by showing that it can be applied to a commercially available stent and it is believed that it can be further utilized by other types of medical implants.
Collapse
Affiliation(s)
- Mahmut Talha Kirimi
- Centre for Medical and Industrial Ultrasonics, James Watt School of Engineering, University of Glasgow, Glasgow, G12 8QQ, UK
| | - Daniel Hoare
- Institute of Cardiovascular and Medical Sciences/British Heart Foundation, University of Glasgow, Glasgow, G12 8QQ, UK
| | - Michael Holsgrove
- BioElectronics Unit, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow, G12 8QQ, UK
| | - Jakup Czyzewski
- BioElectronics Unit, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow, G12 8QQ, UK
| | - Nosrat Mirzai
- BioElectronics Unit, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow, G12 8QQ, UK
| | - John R Mercer
- Institute of Cardiovascular and Medical Sciences/British Heart Foundation, University of Glasgow, Glasgow, G12 8QQ, UK
| | - Steve L Neale
- Centre for Medical and Industrial Ultrasonics, James Watt School of Engineering, University of Glasgow, Glasgow, G12 8QQ, UK
| |
Collapse
|
2
|
Aliqab K, Nadeem I, Khan SR. A Comprehensive Review of In-Body Biomedical Antennas: Design, Challenges and Applications. MICROMACHINES 2023; 14:1472. [PMID: 37512782 PMCID: PMC10385670 DOI: 10.3390/mi14071472] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Revised: 07/11/2023] [Accepted: 07/19/2023] [Indexed: 07/30/2023]
Abstract
In-body biomedical devices (IBBDs) are receiving significant attention in the discovery of solutions to complex medical conditions. Biomedical devices, which can be ingested, injected or implanted in the human body, have made it viable to screen the physiological signs of a patient wirelessly, without regular hospital appointments and routine check-ups, where the antenna is a mandatory element for transferring bio-data from the IBBDs to the external world. However, the design of an in-body antenna is challenging due to the dispersion of the dielectric constant of the tissues and unpredictability of the organ structures of the human body, which can absorb most of the antenna radiation. Therefore, various factors must be considered for an in-body antenna, such as miniaturization, link budget, patient safety, biocompatibility, low power consumption and the ability to work effectively within acceptable medical frequency bands. This paper presents a comprehensive overview of the major facets associated with the design and challenges of in-body antennas. The review comprises surveying the design specifications and implementation methodology, simulation software and testing of in-body biomedical antennas. This work aims to summarize the recent in-body antenna innovations for biomedical applications and indicates the key research challenges.
Collapse
Affiliation(s)
- Khaled Aliqab
- Department of Electrical Engineering, College of Engineering, Jouf University, Sakaka 72388, Saudi Arabia
| | - Iram Nadeem
- Department of Information Engineering and Mathematics Science, University of Siena, 53100 Siena, Italy
| | - Sadeque Reza Khan
- Institute of Sensors, Signals and Systems, School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh EH14 4AS, UK
| |
Collapse
|
3
|
Tai YD, Widdicombe B, Unnithan RR, Grayden DB, John SE. Wearable Transmitter Coil Design for Inductive Wireless Power Transfer to Implantable Devices. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2023; 2023:1-4. [PMID: 38082593 DOI: 10.1109/embc40787.2023.10340600] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
Wireless endovascular sensors and stimulators are emerging biomedical technologies for applications such as endovascular pressure monitoring, hyperthermia, and neural stimulations. Recently, coil-shaped stents have been proposed for inductive power transfer to endovascular devices using the stent as a receiver. However, less work has been done on the external transmitter components, so the maximum power transferable remains unknown. In this work, we design and evaluate a wearable transmitter coil that allows 50 mW power transfer in simulation.Clinical Relevance-This allows more accurate measurements and precise control of endovascular devices.
Collapse
|
4
|
Kim H, Li J, Hsieh YSY, Cho M, Ahn SH, Li C. Photo-Programmed Deformations in Rigid Liquid Crystalline Polymers Triggered by Body Temperature. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2022; 18:e2203772. [PMID: 36169084 DOI: 10.1002/smll.202203772] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2022] [Revised: 09/13/2022] [Indexed: 06/16/2023]
Abstract
Deformations triggered by body heat are desirable in the context of shape-morphing applications because, under the majority of circumstances, the human body maintains a higher temperature than that of its surroundings. However, at present, this bioenergy-triggered action is primarily limited to soft polymeric networks. Thus, herein, the programming of body temperature-triggered deformations into rigid azobenzene-containing liquid crystalline polymers (azo-LCPs) with a glass-transition temperature of 100 °C is demonstrated. To achieve this, a mechano-assisted photo-programming strategy is used to create a metastable state with room-temperature stable residual stress, which is induced by the isomerization of azobenzene. The programmed rigid azo-LCP can undergo large-amplitude body temperature-triggered shape changes within minutes and can be regenerated without any performance degradation. By changing the programming photomasks and irradiation conditions employed, various 2D to 3D shape-morphing architectures, including folded clips, inch-worm structures, spiral structures, and snap-through motions are achieved. When programmed with polarized light, the proposed strategy results in domain-selective activation, generating designed characteristics in multi-domain azo-LCPs. The reported strategy is therefore expected to broaden the applications of azo-LCPs in the fields of biomedical and flexible microelectronic devices.
Collapse
Affiliation(s)
- Hyunsu Kim
- Department of Mechanical and Aerospace Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul, 151-742, Republic of Korea
| | - Jing Li
- Development Center of Plant Germplasm Resources, College of Life Sciences, Shanghai Normal University, Shanghai, 200234, China
- Division of Glycoscience, Department of Chemistry, School of Engineering Sciences in Chemistry, Biotechnology and Health, KTH Royal Institute of Technology, AlbaNova University Centre, Stockholm, SE106 91, Sweden
| | - Yves S Y Hsieh
- Division of Glycoscience, Department of Chemistry, School of Engineering Sciences in Chemistry, Biotechnology and Health, KTH Royal Institute of Technology, AlbaNova University Centre, Stockholm, SE106 91, Sweden
- School of Pharmacy, College of Pharmacy, Taipei Medical University, Taipei, 11031, Taiwan
| | - Maenghyo Cho
- Department of Mechanical and Aerospace Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul, 151-742, Republic of Korea
| | - Sung-Hoon Ahn
- Department of Mechanical and Aerospace Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul, 151-742, Republic of Korea
| | - Chenzhe Li
- School of Aerospace Engineering and Applied Mechanics, Tongji University, 100 Zhangwu Road, Shanghai, 200092, China
- Institute of Advanced Machines and Design, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul, 151-742, Republic of Korea
| |
Collapse
|
5
|
Veletić M, Apu EH, Simić M, Bergsland J, Balasingham I, Contag CH, Ashammakhi N. Implants with Sensing Capabilities. Chem Rev 2022; 122:16329-16363. [PMID: 35981266 DOI: 10.1021/acs.chemrev.2c00005] [Citation(s) in RCA: 25] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Because of the aging human population and increased numbers of surgical procedures being performed, there is a growing number of biomedical devices being implanted each year. Although the benefits of implants are significant, there are risks to having foreign materials in the body that may lead to complications that may remain undetectable until a time at which the damage done becomes irreversible. To address this challenge, advances in implantable sensors may enable early detection of even minor changes in the implants or the surrounding tissues and provide early cues for intervention. Therefore, integrating sensors with implants will enable real-time monitoring and lead to improvements in implant function. Sensor integration has been mostly applied to cardiovascular, neural, and orthopedic implants, and advances in combined implant-sensor devices have been significant, yet there are needs still to be addressed. Sensor-integrating implants are still in their infancy; however, some have already made it to the clinic. With an interdisciplinary approach, these sensor-integrating devices will become more efficient, providing clear paths to clinical translation in the future.
Collapse
Affiliation(s)
- Mladen Veletić
- Department of Electronic Systems, Norwegian University of Science and Technology, 7491 Trondheim, Norway.,The Intervention Centre, Technology and Innovation Clinic, Oslo University Hospital, 0372 Oslo, Norway
| | - Ehsanul Hoque Apu
- Institute for Quantitative Health Science and Engineering (IQ) and Department of Biomedical Engineering (BME), Michigan State University, East Lansing, Michigan 48824, United States.,Division of Hematology and Oncology, Department of Internal Medicine, Michigan Medicine, University of Michigan, Ann Arbor, Michigan 48105, United States
| | - Mitar Simić
- Faculty of Electrical Engineering, University of Banja Luka, 78000 Banja Luka, Bosnia and Herzegovina
| | - Jacob Bergsland
- The Intervention Centre, Technology and Innovation Clinic, Oslo University Hospital, 0372 Oslo, Norway
| | - Ilangko Balasingham
- Department of Electronic Systems, Norwegian University of Science and Technology, 7491 Trondheim, Norway.,The Intervention Centre, Technology and Innovation Clinic, Oslo University Hospital, 0372 Oslo, Norway
| | - Christopher H Contag
- Institute for Quantitative Health Science and Engineering (IQ) and Department of Biomedical Engineering (BME), Michigan State University, East Lansing, Michigan 48824, United States
| | - Nureddin Ashammakhi
- Institute for Quantitative Health Science and Engineering (IQ) and Department of Biomedical Engineering (BME), Michigan State University, East Lansing, Michigan 48824, United States.,Department of Bioengineering, University of California, Los Angeles, California 90095, United States
| |
Collapse
|
6
|
Hoare D, Tsiamis A, Marland JRK, Czyzewski J, Kirimi MT, Holsgrove M, Russell E, Neale SL, Mirzai N, Mitra S, Mercer JR. Predicting Cardiovascular Stent Complications Using Self-Reporting Biosensors for Noninvasive Detection of Disease. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 9:e2105285. [PMID: 35322587 PMCID: PMC9130883 DOI: 10.1002/advs.202105285] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Revised: 02/03/2022] [Indexed: 06/14/2023]
Abstract
Self-reporting implantable medical devices are the future of cardiovascular healthcare. Cardiovascular complications such as blocked arteries that lead to the majority of heart attacks and strokes are frequently treated with inert metal stents that reopen affected vessels. Stents frequently re-block after deployment due to a wound response called in-stent restenosis (ISR). Herein, an implantable miniaturized sensor and telemetry system are developed that can detect this process, discern the different cell types associated with ISR, distinguish sub plaque components as demonstrated with ex vivo samples, and differentiate blood from blood clot, all on a silicon substrate making it suitable for integration onto a vascular stent. This work shows that microfabricated sensors can provide clinically relevant information in settings closer to physiological conditions than previous work with cultured cells.
Collapse
Affiliation(s)
- Daniel Hoare
- Institute of Cardiovascular and Medical Sciences/British Heart FoundationUniversity of GlasgowGlasgowUK
| | - Andreas Tsiamis
- School of EngineeringInstitute for Integrated Micro and Nano SystemsUniversity of EdinburghEdinburghUK
| | - Jamie R. K. Marland
- School of EngineeringInstitute for Integrated Micro and Nano SystemsUniversity of EdinburghEdinburghUK
| | - Jakub Czyzewski
- BioElectronics UnitCollege of MedicalVeterinary and Life SciencesUniversity of GlasgowGlasgowUK
| | - Mahmut T. Kirimi
- Centre for Medical and Industrial UltrasonicsJames Watt School of EngineeringUniversity of GlasgowGlasgowUK
| | - Michael Holsgrove
- BioElectronics UnitCollege of MedicalVeterinary and Life SciencesUniversity of GlasgowGlasgowUK
| | - Ewan Russell
- Centre for Medical and Industrial UltrasonicsJames Watt School of EngineeringUniversity of GlasgowGlasgowUK
| | - Steven L. Neale
- Centre for Medical and Industrial UltrasonicsJames Watt School of EngineeringUniversity of GlasgowGlasgowUK
| | - Nosrat Mirzai
- BioElectronics UnitCollege of MedicalVeterinary and Life SciencesUniversity of GlasgowGlasgowUK
| | - Srinjoy Mitra
- School of EngineeringInstitute for Integrated Micro and Nano SystemsUniversity of EdinburghEdinburghUK
| | - John R. Mercer
- Institute of Cardiovascular and Medical Sciences/British Heart FoundationUniversity of GlasgowGlasgowUK
| |
Collapse
|
7
|
Bussooa A, Hoare D, Kirimi MT, Mitra S, Mirzai N, Neale SL, Mercer JR. Impedimetric Detection and Electromediated Apoptosis of Vascular Smooth Muscle Using Microfabricated Biosensors for Diagnosis and Therapeutic Intervention in Cardiovascular Diseases. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2020; 7:1902999. [PMID: 32999823 PMCID: PMC7509665 DOI: 10.1002/advs.201902999] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2019] [Revised: 01/17/2020] [Indexed: 05/23/2023]
Abstract
Cardiovascular diseases remain a significant global burden with 1-in-3 of all deaths attributable to the consequences of the disease. The main cause is blocked arteries which often remain undetected. Implantable medical devices (IMDs) such as stents and grafts are often used to reopen vessels but over time these too will re-block. A vascular biosensor is developed that can report on cellularity and is amenable to being mounted on a stent or graft for remote reporting. Moreover, the device is designed to also receive currents that can induce a controlled form of cell death, apoptosis. A combined diagnostic and therapeutic biosensor would be transformational for the treatment of vascular diseases such as atherosclerosis and central line access. In this work, a cell sensing and cell apoptosing system based on the same interdigitated electrodes (IDEs) is developed. It is shown that the device is scalable and that by miniaturizing the IDEs, the detection sensitivity is increased. Apoptosis of vascular smooth muscle cells is monitored using continuous impedance measurements at a frequency of 10 kHz and rates of cell death are tracked using fluorescent dyes and live cell imaging.
Collapse
Affiliation(s)
- Anubhav Bussooa
- BHF Cardiovascular Research CentreUniversity of GlasgowGlasgowG12 8TAUK
| | - Daniel Hoare
- BHF Cardiovascular Research CentreUniversity of GlasgowGlasgowG12 8TAUK
| | - Mahmut T. Kirimi
- BHF Cardiovascular Research CentreUniversity of GlasgowGlasgowG12 8TAUK
| | - Srinjoy Mitra
- Scottish Microelectronics CentreKings Buildings CampusUniversity of EdinburghEdinburgh EH9 3FFScotland
| | - Nosrat Mirzai
- Bioelectronics UnitUniversity of GlasgowGlasgowG12 8TAUK
| | - Steve L. Neale
- James Watt School of EngineeringUniversity of GlasgowGlasgowG12 8QQUK
| | - John R. Mercer
- BHF Cardiovascular Research CentreUniversity of GlasgowGlasgowG12 8TAUK
| |
Collapse
|
8
|
Vishnu J, Manivasagam G. Perspectives on smart stents with sensors: From conventional permanent to novel bioabsorbable smart stent technologies. ACTA ACUST UNITED AC 2020. [DOI: 10.1002/mds3.10116] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
- Jithin Vishnu
- Centre for Biomaterials Cellular and Molecular Theranostics CBCMT Vellore Institute of Technology Vellore India
| | - Geetha Manivasagam
- Centre for Biomaterials Cellular and Molecular Theranostics CBCMT Vellore Institute of Technology Vellore India
- IBTN/In ‐ Indian branch of Institute of Biomaterials Tribocorrosion and Nanomedicine Vellore Institute of Technology Vellore India
| |
Collapse
|
9
|
Health Care Monitoring and Treatment for Coronary Artery Diseases: Challenges and Issues. SENSORS 2020; 20:s20154303. [PMID: 32752231 PMCID: PMC7435700 DOI: 10.3390/s20154303] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/23/2020] [Revised: 07/09/2020] [Accepted: 07/12/2020] [Indexed: 01/03/2023]
Abstract
In-stent restenosis concerning the coronary artery refers to the blood clotting-caused re-narrowing of the blocked section of the artery, which is opened using a stent. The failure rate for stents is in the range of 10% to 15%, where they do not remain open, thereby leading to about 40% of the patients with stent implantations requiring repeat procedure within one year, despite increased risk factors and the administration of expensive medicines. Hence, today stent restenosis is a significant cause of deaths globally. Monitoring and treatment matter a lot when it comes to early diagnosis and treatment. A review of the present stent monitoring technology as well as the practical treatment for addressing stent restenosis was conducted. The problems and challenges associated with current stent monitoring technology were illustrated, along with its typical applications. Brief suggestions were given and the progress of stent implants was discussed. It was revealed that prime requisites are needed to achieve good quality implanted stent devices in terms of their size, reliability, etc. This review would positively prompt researchers to augment their efforts towards the expansion of healthcare systems. Lastly, the challenges and concerns associated with nurturing a healthcare system were deliberated with meaningful evaluations.
Collapse
|