1
|
Espinosa MA, Ponce P, Molina A, Borja V, Torres MG, Rojas M. Advancements in Home-Based Devices for Detecting Obstructive Sleep Apnea: A Comprehensive Study. SENSORS (BASEL, SWITZERLAND) 2023; 23:9512. [PMID: 38067885 PMCID: PMC10708697 DOI: 10.3390/s23239512] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Revised: 11/24/2023] [Accepted: 11/25/2023] [Indexed: 12/18/2023]
Abstract
Obstructive Sleep Apnea (OSA) is a respiratory disorder characterized by frequent breathing pauses during sleep. The apnea-hypopnea index is a measure used to assess the severity of sleep apnea and the hourly rate of respiratory events. Despite numerous commercial devices available for apnea diagnosis and early detection, accessibility remains challenging for the general population, leading to lengthy wait times in sleep clinics. Consequently, research on monitoring and predicting OSA has surged. This comprehensive paper reviews devices, emphasizing distinctions among representative apnea devices and technologies for home detection of OSA. The collected articles are analyzed to present a clear discussion. Each article is evaluated according to diagnostic elements, the implemented automation level, and the derived level of evidence and quality rating. The findings indicate that the critical variables for monitoring sleep behavior include oxygen saturation (oximetry), body position, respiratory effort, and respiratory flow. Also, the prevalent trend is the development of level IV devices, measuring one or two signals and supported by prediction software. Noteworthy methods showcasing optimal results involve neural networks, deep learning, and regression modeling, achieving an accuracy of approximately 99%.
Collapse
Affiliation(s)
- Miguel A. Espinosa
- Institute of Advanced Materials for Sustainable Manufacturing, Tecnologico de Monterrey, Mexico City 14380, Mexico; (M.A.E.); (M.R.)
| | - Pedro Ponce
- Institute of Advanced Materials for Sustainable Manufacturing, Tecnologico de Monterrey, Mexico City 14380, Mexico; (M.A.E.); (M.R.)
| | - Arturo Molina
- Institute of Advanced Materials for Sustainable Manufacturing, Tecnologico de Monterrey, Mexico City 14380, Mexico; (M.A.E.); (M.R.)
| | - Vicente Borja
- Faculty of Engineering, Universidad Nacional Autonoma de Mexico, Mexico City 04510, Mexico;
| | - Martha G. Torres
- Sleep Medicine Unit, Instituto Nacional de Enfermedades Respiratorias Ismael Cosio Villegas, Mexico City 14080, Mexico;
| | - Mario Rojas
- Institute of Advanced Materials for Sustainable Manufacturing, Tecnologico de Monterrey, Mexico City 14380, Mexico; (M.A.E.); (M.R.)
| |
Collapse
|
2
|
Martín-González S, Ravelo-García AG, Navarro-Mesa JL, Hernández-Pérez E. Combining Heart Rate Variability and Oximetry to Improve Apneic Event Screening in Non-Desaturating Patients. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23094267. [PMID: 37177472 PMCID: PMC10181515 DOI: 10.3390/s23094267] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 04/17/2023] [Accepted: 04/18/2023] [Indexed: 05/15/2023]
Abstract
In this paper, we thoroughly analyze the detection of sleep apnea events in the context of Obstructive Sleep Apnea (OSA), which is considered a public health problem because of its high prevalence and serious health implications. We especially evaluate patients who do not always show desaturations during apneic episodes (non-desaturating patients). For this purpose, we use a database (HuGCDN2014-OXI) that includes desaturating and non-desaturating patients, and we use the widely used Physionet Apnea Dataset for a meaningful comparison with prior work. Our system combines features extracted from the Heart-Rate Variability (HRV) and SpO2, and it explores their potential to characterize desaturating and non-desaturating events. The HRV-based features include spectral, cepstral, and nonlinear information (Detrended Fluctuation Analysis (DFA) and Recurrence Quantification Analysis (RQA)). SpO2-based features include temporal (variance) and spectral information. The features feed a Linear Discriminant Analysis (LDA) classifier. The goal is to evaluate the effect of using these features either individually or in combination, especially in non-desaturating patients. The main results for the detection of apneic events are: (a) Physionet success rate of 96.19%, sensitivity of 95.74% and specificity of 95.25% (Area Under Curve (AUC): 0.99); (b) HuGCDN2014-OXI of 87.32%, 83.81% and 88.55% (AUC: 0.934), respectively. The best results for the global diagnosis of OSA patients (HuGCDN2014-OXI) are: success rate of 95.74%, sensitivity of 100%, and specificity of 89.47%. We conclude that combining both features is the most accurate option, especially when there are non-desaturating patterns among the recordings under study.
Collapse
Affiliation(s)
- Sofía Martín-González
- Institute for Technological Development and Innovation in Communications, Universidad de Las Palmas de Gran Canaria, 35017 Las Palmas de Gran Canaria, Spain
| | - Antonio G Ravelo-García
- Institute for Technological Development and Innovation in Communications, Universidad de Las Palmas de Gran Canaria, 35017 Las Palmas de Gran Canaria, Spain
- Interactive Technologies Institute (ITI/LARSyS and ARDITI), 9020-105 Funchal, Portugal
| | - Juan L Navarro-Mesa
- Institute for Technological Development and Innovation in Communications, Universidad de Las Palmas de Gran Canaria, 35017 Las Palmas de Gran Canaria, Spain
| | - Eduardo Hernández-Pérez
- Institute for Technological Development and Innovation in Communications, Universidad de Las Palmas de Gran Canaria, 35017 Las Palmas de Gran Canaria, Spain
| |
Collapse
|
3
|
Wang S, Xuan W, Chen D, Gu Y, Liu F, Chen J, Xia S, Dong S, Luo J. Machine Learning Assisted Wearable Wireless Device for Sleep Apnea Syndrome Diagnosis. BIOSENSORS 2023; 13:bios13040483. [PMID: 37185558 PMCID: PMC10136920 DOI: 10.3390/bios13040483] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 03/31/2023] [Accepted: 04/14/2023] [Indexed: 05/17/2023]
Abstract
Sleep apnea syndrome (SAS) is a common but underdiagnosed health problem related to impaired quality of life and increased cardiovascular risk. In order to solve the problem of complicated and expensive operation procedures for clinical diagnosis of sleep apnea, here we propose a small and low-cost wearable apnea diagnostic system. The system uses a photoplethysmography (PPG) optical sensor to collect human pulse wave signals and blood oxygen saturation synchronously. Then multiscale entropy and random forest algorithms are used to process the PPG signal for analysis and diagnosis of sleep apnea. The SAS determination is based on the comprehensive diagnosis of the PPG signal and blood oxygen saturation signal, and the blood oxygen is used to exclude the error induced by non-pathological factors. The performance of the system is compared with the Compumedics Grael PSG (Polysomnography) sleep monitoring system. This simple diagnostic system provides a feasible technical solution for portable and low-cost screening and diagnosis of SAS patients with a high accuracy of over 85%.
Collapse
Affiliation(s)
- Shaokui Wang
- Ministry of Education Key Laboratory of RF Circuits and Systems, College of Electronics & Information Hangzhou Dianzi University, Hangzhou 310018, China
| | - Weipeng Xuan
- Ministry of Education Key Laboratory of RF Circuits and Systems, College of Electronics & Information Hangzhou Dianzi University, Hangzhou 310018, China
| | - Ding Chen
- Ministry of Education Key Laboratory of RF Circuits and Systems, College of Electronics & Information Hangzhou Dianzi University, Hangzhou 310018, China
| | - Yexin Gu
- Ministry of Education Key Laboratory of RF Circuits and Systems, College of Electronics & Information Hangzhou Dianzi University, Hangzhou 310018, China
| | - Fuhai Liu
- Ministry of Education Key Laboratory of RF Circuits and Systems, College of Electronics & Information Hangzhou Dianzi University, Hangzhou 310018, China
| | - Jinkai Chen
- Ministry of Education Key Laboratory of RF Circuits and Systems, College of Electronics & Information Hangzhou Dianzi University, Hangzhou 310018, China
| | - Shudong Xia
- The Fourth Affiliated Hospital Zhejiang University School of Medicine, Yiwu 322000, China
| | - Shurong Dong
- Key Laboratory of Advanced Micro/Nano Electronic Devices & Smart Systems of Zhejiang, College of Information Science & Electronic Engineering, Zhejiang University, Hangzhou 310027, China
| | - Jikui Luo
- Ministry of Education Key Laboratory of RF Circuits and Systems, College of Electronics & Information Hangzhou Dianzi University, Hangzhou 310018, China
- Key Laboratory of Advanced Micro/Nano Electronic Devices & Smart Systems of Zhejiang, College of Information Science & Electronic Engineering, Zhejiang University, Hangzhou 310027, China
| |
Collapse
|
4
|
García-López I, Pramono RXA, Rodriguez-Villegas E. Artifacts classification and apnea events detection in neck photoplethysmography signals. Med Biol Eng Comput 2022; 60:3539-3554. [PMID: 36245021 PMCID: PMC9646626 DOI: 10.1007/s11517-022-02666-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Accepted: 09/12/2022] [Indexed: 11/11/2022]
Abstract
The novel pulse oximetry measurement site of the neck is a promising location for multi-modal physiological monitoring. Specifically, in the context of respiratory monitoring, in which it is important to have direct information about airflow. The neck makes this possible, in contrast to common photoplethysmography (PPG) sensing sites. However, this PPG signal is susceptible to artifacts that critically impair the signal quality. To fully exploit neck PPG for reliable physiological parameters extraction and apneas monitoring, this paper aims to develop two classification algorithms for artifacts and apnea detection. Features from the time, correlogram, and frequency domains were extracted. Two SVM classifiers with RBF kernels were trained for different window (W) lengths and thresholds (Thd) of corruption. For artifacts classification, the maximum performance was attained for the parameters combination of [W = 6s-Thd= 20%], with an average accuracy= 85.84%(ACC), sensitivity= 85.43%(SE) and specificity= 86.26%(SP). For apnea detection, the model [W = 10s-Thd= 50%] maximized all the performance metrics significantly (ACC= 88.25%, SE= 89.03%, SP= 87.42%). The findings of this proof of concept are significant for denoising novel neck PPG signals, and demonstrate, for the first time, that it is possible to promptly detect apnea events from neck PPG signals in an instantaneous manner. This could make a big impact in crucial real-time applications, like devices to prevent sudden-unexpected-death-in-epilepsy (SUDEP).
Collapse
Affiliation(s)
- Irene García-López
- Wearable Technologies Lab, Department of Electrical and Electronic Engineering, Imperial College London, London, SW7 2BT UK
| | - Renard Xaviero Adhi Pramono
- Wearable Technologies Lab, Department of Electrical and Electronic Engineering, Imperial College London, London, SW7 2BT UK
| | - Esther Rodriguez-Villegas
- Wearable Technologies Lab, Department of Electrical and Electronic Engineering, Imperial College London, London, SW7 2BT UK
| |
Collapse
|
5
|
Sharma M, Kumar K, Kumar P, Tan RS, Rajendra Acharya U. Pulse oximetry SpO2signal for automated identification of sleep apnea: a review and future trends. Physiol Meas 2022; 43. [PMID: 36215979 DOI: 10.1088/1361-6579/ac98f0] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Accepted: 10/10/2022] [Indexed: 02/07/2023]
Abstract
Sleep apnea (SA) is characterized by intermittent episodes of apnea or hypopnea paused or reduced breathing, respectively each lasting at least ten seconds that occur during sleep. SA has an estimated global prevalence of 200 million and is associated with medical comorbidity, and sufferers are also more likely to sustain traffic- and work-related injury due to daytime somnolence. SA is amenable to treatment if detected early. Polysomnography (PSG) involving multi-channel signal acquisition is the reference standard for diagnosing SA but is onerous and costly. For home-based detection of SA, single-channelSpO2signal acquisition using portable pulse oximeters is feasible. Machine (ML) and deep learning (DL) models have been developed for automated classification of SA versus no SA usingSpO2signals alone. In this work, we review studies published between 2012 and 2022 on the use of ML and DL forSpO2signal-based diagnosis of SA. A literature search based on PRISMA recommendations yielded 297 publications, of which 31 were selected after considering the inclusion and exclusion criteria. There were 20 ML and 11 DL models; their methods, differences, results, merits, and limitations were discussed. Many studies reported encouraging performance, which indicates the utility ofSpO2signals in wearable devices for home-based SA detection.
Collapse
Affiliation(s)
- Manish Sharma
- Department of Electrical and Computer Science Engineering, Institute of Infrastructure Technology Research and Management, Ahmedabad 380026, India
| | - Kamlesh Kumar
- Department of Electrical and Computer Science Engineering, Institute of Infrastructure Technology Research and Management, Ahmedabad 380026, India
| | - Prince Kumar
- Department of Electrical and Computer Science Engineering, Institute of Infrastructure Technology Research and Management, Ahmedabad 380026, India
| | - Ru-San Tan
- Department of Cardiology, National Heart Centre Singapore, Singapore 169609, Singapore
| | - U Rajendra Acharya
- Department of Electronics and Computer Engineering, Ngee Ann Polytechnic, Singapore 639798, Singapore.,Department of Bioinformatics and Medical Engineering, Asia University, Taichung 41354, Taiwan.,Department of Biomedical Engineering, School of Science and Technology, Singapore 639798, Singapore
| |
Collapse
|
6
|
Pu Q, Wu Z, Li AL, Guo XX, Hu JJ, Li XY. Association between poor sleep quality and an increased risk of dry eye disease in patients with obstructive sleep apnea syndrome. Front Med (Lausanne) 2022; 9:870391. [PMID: 36388897 PMCID: PMC9659957 DOI: 10.3389/fmed.2022.870391] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2022] [Accepted: 10/05/2022] [Indexed: 11/26/2022] Open
Abstract
Purpose Obstructive sleep apnea (OSA) is related to an increased incidence of dry eye disease (DED). However, their exact relationship is unknown and requires further well-designed studies with advanced mechanisms detection. Patients and methods This case–control study included 125 OSA cases and 125 age–gender-matched controls enrolled in the hospital between 1 January and 1 October 2021. OSA diagnosis and classification were performed using a polysomnography (PSG) assay. Detailed ophthalmological examinations, including the Schirmer I test, corneal staining, and ocular surface disease index (OSDI), were used to detect DED-related parameters. A comprehensive ocular surface assay was performed to measure a series of parameters, including first non-invasive first tear film break-up time (f-NIBUT), average non-invasive first tear film break-up time (av-NIBUT), tear meniscus height (TMH), and loss of meibomian gland. In addition, the Pittsburgh Sleep Quality Index (PSQI) scale was used to assess sleep quality. Results Compared to the control, the OSA group showed an increased DED risk (P = 0.016) along with an increased PSQI score and a higher rate of poor quality sleep (P < 0.001 and P = 0.007, respectively). Stratification of OSA cases indicated that DED-related parameters were impaired in patients with severe OSA (P < 0.05). The analysis of DED-parameters-related factors showed significant correlations between OSA-related indexes and PSQI (P < 0.05). Moreover, the poor sleep quality group in the OSA cases showed worse DED-related parameters (P < 0.05), which was not observed in the control group. Conclusion OSA, especially the severe stage OSA, was related to an increased risk of DED. Also, sleep quality was correlated with the onset of both OSA and DED, where poor sleep quality revealed a relationship between OSA and the risk of DED. Overall, our findings provided evidence for advanced management of DED and OSA in future.
Collapse
Affiliation(s)
- Qi Pu
- Department of Ophthalmology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Zhen Wu
- Department of Ear, Nose, and Throat, Changshu No. 2 People’s Hospital, Changshu, China
| | - Ao-Ling Li
- Department of Ophthalmology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Xiao-Xiao Guo
- Department of Ophthalmology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Jing-Jie Hu
- Department of Ophthalmology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Xin-Yu Li
- Department of Ophthalmology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
- *Correspondence: Xin-Yu Li,
| |
Collapse
|
7
|
Setiawan F, Lin CW. A Deep Learning Framework for Automatic Sleep Apnea Classification Based on Empirical Mode Decomposition Derived from Single-Lead Electrocardiogram. Life (Basel) 2022; 12:1509. [PMID: 36294943 PMCID: PMC9605343 DOI: 10.3390/life12101509] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Revised: 08/30/2022] [Accepted: 09/14/2022] [Indexed: 11/29/2022] Open
Abstract
BACKGROUND Although polysomnography (PSG) is a gold standard tool for diagnosing sleep apnea (SA), it can reduce the patient's sleep quality by the placement of several disturbing sensors and can only be interpreted by a highly trained sleep technician or scientist. In recent years, electrocardiogram (ECG)-derived respiration (EDR) and heart rate variability (HRV) have been used to automatically diagnose SA and reduce the drawbacks of PSG. Up to now, most of the proposed approaches focus on machine-learning (ML) algorithms and feature engineering, which require prior expert knowledge and experience. The present study proposes an SA detection algorithm to differentiate a normal and apnea event using a deep-learning (DL) framework based on 1D and 2D deep CNN with empirical mode decomposition (EMD) of a preprocessed ECG signal. The EMD is ideally suited to extract essential components which are characteristic of the underlying biological or physiological processes. In addition, the simple and compact architecture of 1D deep CNN, which only performs 1D convolutions, and pretrained 2D deep CNNs, are suitable for real-time and low-cost hardware implementation. METHOD This study was validated using 7 h to nearly 10 h overnight ECG recordings from 33 subjects with an average apnea-hypopnea index (AHI) of 30.23/h originated from PhysioNet Apnea-ECG database (PAED). In preprocessing, the raw ECG signal was normalized and filtered using the FIR band pass filter. The preprocessed ECG signal was then decomposed using the empirical mode decomposition (EMD) technique to generate several features. Several important generated features were selected using neighborhood component analysis (NCA). Finally, deep learning algorithm based on 1D and 2D deep CNN were used to perform the classification of normal and apnea event. The synthetic minority oversampling technique (SMOTE) was also applied to evaluate the influence of the imbalanced data problem. RESULTS The segment-level classification performance had 93.8% accuracy with 94.9% sensitivity and 92.7% specificity based on 5-fold cross-validation (5fold-CV), meanwhile, the subject-level classification performance had 83.5% accuracy with 75.9% sensitivity and 88.7% specificity based on leave-one-subject-out cross-validation (LOSO-CV). CONCLUSION A novel and robust SA detection algorithm based on the ECG decomposed signal using EMD and deep CNN was successfully developed in this study.
Collapse
Affiliation(s)
- Febryan Setiawan
- Department of Biomedical Engineering, College of Engineering, National Cheng Kung University, Tainan 701, Taiwan
| | - Che-Wei Lin
- Department of Biomedical Engineering, College of Engineering, National Cheng Kung University, Tainan 701, Taiwan
- Institute of Gerontology, College of Medicine, National Cheng Kung University, Tainan 701, Taiwan
- Medical Device Innovation Center, National Cheng Kung University, Tainan 701, Taiwan
- Institute of Medical Informatics, College of Electrical Engineering and Computer Science, National Cheng Kung University, Tainan 701, Taiwan
| |
Collapse
|
8
|
Abstract
Sleep studies have typically followed criteria established many decades ago, but emerging technologies allow signal analyses that go far beyond the scoring rules for manual analysis of sleep recordings. These technologies may apply to the analysis of signals obtained in standard polysomnography in addition to novel signals more recently developed that provide both direct and indirect measures of sleep and breathing in the ambulatory setting. Automated analysis of signals such as electroencephalogram and oxygen saturation, in addition to heart rate and rhythm, provides a wealth of additional information on sleep and breathing disturbances and their potential for comorbidity.
Collapse
Affiliation(s)
- Walter T McNicholas
- Department of Respiratory and Sleep Medicine, School of Medicine, University College Dublin, St. Vincent's Hospital Group, Elm Park, Dublin 4, Ireland.
| |
Collapse
|
9
|
Obstructive sleep apnea screening from unprocessed ECG signals using statistical modelling. Biomed Signal Process Control 2021. [DOI: 10.1016/j.bspc.2021.102685] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
10
|
Huysmans D, Borzée P, Buyse B, Testelmans D, Van Huffel S, Varon C. Sleep Diagnostics for Home Monitoring of Sleep Apnea Patients. Front Digit Health 2021; 3:685766. [PMID: 34713155 PMCID: PMC8521961 DOI: 10.3389/fdgth.2021.685766] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Accepted: 05/11/2021] [Indexed: 12/04/2022] Open
Abstract
Objectives: Sleep time information is essential for monitoring of obstructive sleep apnea (OSA), as the severity assessment depends on the number of breathing disturbances per hour of sleep. However, clinical procedures for sleep monitoring rely on numerous uncomfortable sensors, which could affect sleeping patterns. Therefore, an automated method to identify sleep intervals from unobtrusive data is required. However, most unobtrusive sensors suffer from data loss and sensitivity to movement artifacts. Thus, current sleep detection methods are inadequate, as these require long intervals of good quality. Moreover, sleep monitoring of OSA patients is often less reliable due to heart rate disturbances, movement and sleep fragmentation. The primary aim was to develop a sleep-wake classifier for sleep time estimation of suspected OSA patients, based on single short-term segments of their cardiac and respiratory signals. The secondary aim was to define metrics to detect OSA patients directly from their predicted sleep-wake pattern and prioritize them for clinical diagnosis. Methods: This study used a dataset of 183 suspected OSA patients, of which 36 test subjects. First, a convolutional neural network was designed for sleep-wake classification based on healthier patients (AHI < 10). It employed single 30 s epochs of electrocardiograms and respiratory inductance plethysmograms. Sleep information and Total Sleep Time (TST) was derived for all patients using the short-term segments. Next, OSA patients were detected based on the average confidence of sleep predictions and the percentage of sleep-wake transitions in the predicted sleep architecture. Results: Sleep-wake classification on healthy, mild and moderate patients resulted in moderate κ scores of 0.51, 0.49, and 0.48, respectively. However, TST estimates decreased in accuracy with increasing AHI. Nevertheless, severe patients were detected with a sensitivity of 78% and specificity of 89%, and prioritized for clinical diagnosis. As such, their inaccurate TST estimate becomes irrelevant. Excluding detected OSA patients resulted in an overall estimated TST with a mean bias error of 21.9 (± 55.7) min and Pearson correlation of 0.74 to the reference. Conclusion: The presented framework offered a realistic tool for unobtrusive sleep monitoring of suspected OSA patients. Moreover, it enabled fast prioritization of severe patients for clinical diagnosis.
Collapse
Affiliation(s)
- Dorien Huysmans
- STADIUS Center for Dynamical Systems, Signal Processing and Data Analytics, Department of Electrical Engineering (ESAT), KU Leuven, Leuven, Belgium
| | - Pascal Borzée
- Department of Pneumology, UZ Leuven, Leuven, Belgium
| | - Bertien Buyse
- Department of Pneumology, UZ Leuven, Leuven, Belgium
| | | | - Sabine Van Huffel
- STADIUS Center for Dynamical Systems, Signal Processing and Data Analytics, Department of Electrical Engineering (ESAT), KU Leuven, Leuven, Belgium
| | - Carolina Varon
- STADIUS Center for Dynamical Systems, Signal Processing and Data Analytics, Department of Electrical Engineering (ESAT), KU Leuven, Leuven, Belgium
- e-Media Research Lab, Department of Electrical Engineering (ESAT), KU Leuven, Leuven, Belgium
| |
Collapse
|
11
|
Hanif U, Leary E, Schneider L, Paulsen R, Morse AM, Blackman A, Schweitzer P, Kushida CA, Liu S, Jennum P, Sorensen H, Mignot E. Estimation of Apnea-Hypopnea Index using Deep Learning on 3D Craniofacial Scans. IEEE J Biomed Health Inform 2021; 25:4185-4194. [PMID: 33961569 DOI: 10.1109/jbhi.2021.3078127] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Obstructive sleep apnea (OSA) is characterized by decreased breathing events that occur through the night, with severity reported as the apnea-hypopnea index (AHI), which is associated with certain craniofacial features. In this study, we used data from 1366 patients collected as part of Stanford Technology Analytics and Genomics in Sleep (STAGES) across 11 US and Canadian sleep clinics and analyzed 3D craniofacial scans with the goal of predicting AHI, as measured using gold standard nocturnal polysomnography (PSG). First, the algorithm detects pre-specified landmarks on mesh objects and aligns scans in 3D space. Subsequently, 2D images and depth maps are generated by rendering and rotating scans by 45-degree increments. Resulting images were stacked as channels and used as input to multi-view convolutional neural networks, which were trained and validated in a supervised manner to predict AHI values derived from PSGs. The proposed model achieved a mean absolute error of 11.38 events/hour, a Pearson correlation coefficient of 0.4, and accuracy for predicting OSA of 67% using 10-fold cross-validation. The model improved further by adding patient demographics and variables from questionnaires. We also show that the model performed at the level of three sleep medicine specialists, who used clinical experience to predict AHI based on 3D scan displays. Finally, we created topographic displays of the most important facial features used by the model to predict AHI, showing importance of the neck and chin area. The proposed algorithm has potential to serve as an inexpensive and efficient screening tool for individuals with suspected OSA.
Collapse
|
12
|
Rehouma H, Noumeir R, Essouri S, Jouvet P. Advancements in Methods and Camera-Based Sensors for the Quantification of Respiration. SENSORS (BASEL, SWITZERLAND) 2020; 20:E7252. [PMID: 33348827 PMCID: PMC7766256 DOI: 10.3390/s20247252] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/07/2020] [Revised: 12/09/2020] [Accepted: 12/15/2020] [Indexed: 01/22/2023]
Abstract
Assessment of respiratory function allows early detection of potential disorders in the respiratory system and provides useful information for medical management. There is a wide range of applications for breathing assessment, from measurement systems in a clinical environment to applications involving athletes. Many studies on pulmonary function testing systems and breath monitoring have been conducted over the past few decades, and their results have the potential to broadly impact clinical practice. However, most of these works require physical contact with the patient to produce accurate and reliable measures of the respiratory function. There is still a significant shortcoming of non-contact measuring systems in their ability to fit into the clinical environment. The purpose of this paper is to provide a review of the current advances and systems in respiratory function assessment, particularly camera-based systems. A classification of the applicable research works is presented according to their techniques and recorded/quantified respiration parameters. In addition, the current solutions are discussed with regards to their direct applicability in different settings, such as clinical or home settings, highlighting their specific strengths and limitations in the different environments.
Collapse
Affiliation(s)
- Haythem Rehouma
- École de Technologie Supérieure, Montreal, QC H3T 1C5, Canada;
| | - Rita Noumeir
- École de Technologie Supérieure, Montreal, QC H3T 1C5, Canada;
| | - Sandrine Essouri
- CHU Sainte-Justine, Montreal, QC H3T 1C5, Canada; (S.E.); (P.J.)
| | - Philippe Jouvet
- CHU Sainte-Justine, Montreal, QC H3T 1C5, Canada; (S.E.); (P.J.)
| |
Collapse
|
13
|
O'Mahony AM, Garvey JF, McNicholas WT. Technologic advances in the assessment and management of obstructive sleep apnoea beyond the apnoea-hypopnoea index: a narrative review. J Thorac Dis 2020; 12:5020-5038. [PMID: 33145074 PMCID: PMC7578472 DOI: 10.21037/jtd-sleep-2020-003] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Obstructive sleep apnoea (OSA) is a growing and serious worldwide health problem with significant health and socioeconomic consequences. Current diagnostic testing strategies are limited by cost, access to resources and over reliance on one measure, namely the apnoea-hypopnoea frequency per hour (AHI). Recent evidence supports moving away from the AHI as the principle measure of OSA severity towards a more personalised approach to OSA diagnosis and treatment that includes phenotypic and biological traits. Novel advances in technology include the use of signals such as heart rate variability (HRV), oximetry and peripheral arterial tonometry (PAT) as alternative or additional measures. Ubiquitous use of smartphones and developments in wearable technology have also led to increased availability of applications and devices to facilitate home screening of at-risk populations, although current evidence indicates relatively poor accuracy in comparison with the traditional gold standard polysomnography (PSG). In this review, we evaluate the current strategies for diagnosing OSA in the context of their limitations, potential physiological targets as alternatives to AHI and the role of novel technology in OSA. We also evaluate the current evidence for using newer technologies in OSA diagnosis, the physiological targets such as smartphone applications and wearable technology. Future developments in OSA diagnosis and assessment will likely focus increasingly on systemic effects of sleep disordered breathing (SDB) such as changes in nocturnal oxygen and blood pressure (BP); and may also include other factors such as circulating biomarkers. These developments will likely require a re-evaluation of the diagnostic and grading criteria for clinically significant OSA.
Collapse
Affiliation(s)
- Anne M O'Mahony
- School of Medicine, University College Dublin, Dublin, Ireland
| | - John F Garvey
- School of Medicine, University College Dublin, Dublin, Ireland
| | - Walter T McNicholas
- School of Medicine, University College Dublin, Dublin, Ireland.,First Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
| |
Collapse
|
14
|
Calderón JM, Álvarez-Pitti J, Cuenca I, Ponce F, Redon P. Development of a Minimally Invasive Screening Tool to Identify Obese Pediatric Population at Risk of Obstructive Sleep Apnea/Hypopnea Syndrome. Bioengineering (Basel) 2020; 7:E131. [PMID: 33086521 PMCID: PMC7712243 DOI: 10.3390/bioengineering7040131] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Revised: 10/14/2020] [Accepted: 10/17/2020] [Indexed: 01/20/2023] Open
Abstract
Obstructive sleep apnea syndrome is a reduction of the airflow during sleep which not only produces a reduction in sleep quality but also has major health consequences. The prevalence in the obese pediatric population can surpass 50%, and polysomnography is the current gold standard method for its diagnosis. Unfortunately, it is expensive, disturbing and time-consuming for experienced professionals. The objective is to develop a patient-friendly screening tool for the obese pediatric population to identify those children at higher risk of suffering from this syndrome. Three supervised learning classifier algorithms (i.e., logistic regression, support vector machine and AdaBoost) common in the field of machine learning were trained and tested on two very different datasets where oxygen saturation raw signal was recorded. The first dataset was the Childhood Adenotonsillectomy Trial (CHAT) consisting of 453 individuals, with ages between 5 and 9 years old and one-third of the patients being obese. Cross-validation was performed on the second dataset from an obesity assessment consult at the Pediatric Department of the Hospital General Universitario of Valencia. A total of 27 patients were recruited between 5 and 17 years old; 42% were girls and 63% were obese. The performance of each algorithm was evaluated based on key performance indicators (e.g., area under the curve, accuracy, recall, specificity and positive predicted value). The logistic regression algorithm outperformed (accuracy = 0.79, specificity = 0.96, area under the curve = 0.9, recall = 0.62 and positive predictive value = 0.94) the support vector machine and the AdaBoost algorithm when trained with the CHAT datasets. Cross-validation tests, using the Hospital General de Valencia (HG) dataset, confirmed the higher performance of the logistic regression algorithm in comparison with the others. In addition, only a minor loss of performance (accuracy = 0.75, specificity = 0.88, area under the curve = 0.85, recall = 0.62 and positive predictive value = 0.83) was observed despite the differences between the datasets. The proposed minimally invasive screening tool has shown promising performance when it comes to identifying children at risk of suffering obstructive sleep apnea syndrome. Moreover, it is ideal to be implemented in an outpatient consult in primary and secondary care.
Collapse
Affiliation(s)
- José Miguel Calderón
- Fundación Investigación Hospital Clínico (INCLIVA), Avda. Menedez Pelayo 4, 46010 Valencia, Spain; (J.M.C.); (I.C.)
| | - Julio Álvarez-Pitti
- Pediatric Department, Consorcio Hospital General Universitario de Valencia, Avda. Tres Cruces s/n, 46014 Valencia, Spain; (J.Á.-P.); (F.P.)
| | - Irene Cuenca
- Fundación Investigación Hospital Clínico (INCLIVA), Avda. Menedez Pelayo 4, 46010 Valencia, Spain; (J.M.C.); (I.C.)
| | - Francisco Ponce
- Pediatric Department, Consorcio Hospital General Universitario de Valencia, Avda. Tres Cruces s/n, 46014 Valencia, Spain; (J.Á.-P.); (F.P.)
- CIBEROBN, Health Institute Carlos III, Av. Monforte de Lemos, 3-5. Pavilion 11, 28029 Madrid, Spain
| | - Pau Redon
- Pediatric Department, Consorcio Hospital General Universitario de Valencia, Avda. Tres Cruces s/n, 46014 Valencia, Spain; (J.Á.-P.); (F.P.)
- CIBEROBN, Health Institute Carlos III, Av. Monforte de Lemos, 3-5. Pavilion 11, 28029 Madrid, Spain
| |
Collapse
|