1
|
Toy J, Bosson N, Schlesinger S, Gausche-Hill M, Stratton S. Artificial intelligence to support out-of-hospital cardiac arrest care: A scoping review. Resusc Plus 2023; 16:100491. [PMID: 37965243 PMCID: PMC10641545 DOI: 10.1016/j.resplu.2023.100491] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Revised: 09/23/2023] [Accepted: 10/11/2023] [Indexed: 11/16/2023] Open
Abstract
Background Artificial intelligence (AI) has demonstrated significant potential in supporting emergency medical services personnel during out-of-hospital cardiac arrest (OHCA) care; however, the extent of research evaluating this topic is unknown. This scoping review examines the breadth of literature on the application of AI in early OHCA care. Methods We conducted a search of PubMed®, Embase, and Web of Science in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses Extension for Scoping Reviews guidelines. Articles focused on non-traumatic OHCA and published prior to January 18th, 2023 were included. Studies were excluded if they did not use an AI intervention (including machine learning, deep learning, or natural language processing), or did not utilize data from the prehospital phase of care. Results Of 173 unique articles identified, 54 (31%) were included after screening. Of these studies, 15 (28%) were from the year 2022 and with an increasing trend annually starting in 2019. The majority were carried out by multinational collaborations (20/54, 38%) with additional studies from the United States (10/54, 19%), Korea (5/54, 10%), and Spain (3/54, 6%). Studies were classified into three major categories including ECG waveform classification and outcome prediction (24/54, 44%), early dispatch-level detection and outcome prediction (7/54, 13%), return of spontaneous circulation and survival outcome prediction (15/54, 20%), and other (9/54, 16%). All but one study had a retrospective design. Conclusions A small but growing body of literature exists describing the use of AI to augment early OHCA care.
Collapse
Affiliation(s)
- Jake Toy
- University of California Los Angeles, Fielding School of Public Health, 650 Charles E Young Drive South, Los Angeles, CA 90095, USA
- Harbor-UCLA Department of Emergency Medicine & The Lundquist Research Institute, 1000 W Carson Street, Torrance, CA 90502, USA
- Los Angeles County EMS Agency, 10100 Pioneer Blvd, Santa Fe Springs, CA 90670, USA
- David Geffen School of Medicine at UCLA, Department of Emergency Medicine, 10833 Le Conte Ave, Los Angeles, CA 90095, USA
| | - Nichole Bosson
- Harbor-UCLA Department of Emergency Medicine & The Lundquist Research Institute, 1000 W Carson Street, Torrance, CA 90502, USA
- Los Angeles County EMS Agency, 10100 Pioneer Blvd, Santa Fe Springs, CA 90670, USA
- David Geffen School of Medicine at UCLA, Department of Emergency Medicine, 10833 Le Conte Ave, Los Angeles, CA 90095, USA
| | - Shira Schlesinger
- Harbor-UCLA Department of Emergency Medicine & The Lundquist Research Institute, 1000 W Carson Street, Torrance, CA 90502, USA
- David Geffen School of Medicine at UCLA, Department of Emergency Medicine, 10833 Le Conte Ave, Los Angeles, CA 90095, USA
| | - Marianne Gausche-Hill
- Harbor-UCLA Department of Emergency Medicine & The Lundquist Research Institute, 1000 W Carson Street, Torrance, CA 90502, USA
- Los Angeles County EMS Agency, 10100 Pioneer Blvd, Santa Fe Springs, CA 90670, USA
- David Geffen School of Medicine at UCLA, Department of Emergency Medicine, 10833 Le Conte Ave, Los Angeles, CA 90095, USA
| | - Samuel Stratton
- University of California Los Angeles, Fielding School of Public Health, 650 Charles E Young Drive South, Los Angeles, CA 90095, USA
- Orange County California Emergency Medical Services Agency, 405 W. 5th Street, Santa Ana, CA 92705, USA
| |
Collapse
|
2
|
Chee ML, Chee ML, Huang H, Mazzochi K, Taylor K, Wang H, Feng M, Ho AFW, Siddiqui FJ, Ong MEH, Liu N. Artificial intelligence and machine learning in prehospital emergency care: A scoping review. iScience 2023; 26:107407. [PMID: 37609632 PMCID: PMC10440716 DOI: 10.1016/j.isci.2023.107407] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/24/2023] Open
Abstract
Our scoping review provides a comprehensive analysis of the landscape of artificial intelligence (AI) applications in prehospital emergency care (PEC). It contributes to the field by highlighting the most studied AI applications and identifying the most common methodological approaches across 106 included studies. The findings indicate a promising future for AI in PEC, with many unique use cases, such as prognostication, demand prediction, resource optimization, and the Internet of Things continuous monitoring systems. Comparisons with other approaches showed AI outperforming clinicians and non-AI algorithms in most cases. However, most studies were internally validated and retrospective, highlighting the need for rigorous prospective validation of AI applications before implementation in clinical settings. We identified knowledge and methodological gaps using an evidence map, offering a roadmap for future investigators. We also discussed the significance of explainable AI for establishing trust in AI systems among clinicians and facilitating real-world validation of AI models.
Collapse
Affiliation(s)
- Marcel Lucas Chee
- Faculty of Medicine, Nursing and Health Sciences, Monash University, Melbourne, VIC, Australia
| | - Mark Leonard Chee
- Faculty of Health and Medical Sciences, University of Adelaide, Adelaide, SA, Australia
| | - Haotian Huang
- Faculty of Medicine, Nursing and Health Sciences, Monash University, Melbourne, VIC, Australia
| | - Katelyn Mazzochi
- Faculty of Medicine, Nursing and Health Sciences, Monash University, Melbourne, VIC, Australia
| | - Kieran Taylor
- Faculty of Medicine, Nursing and Health Sciences, Monash University, Melbourne, VIC, Australia
| | - Han Wang
- Saw Swee Hock School of Public Health, National University of Singapore, Singapore, Singapore
| | - Mengling Feng
- Saw Swee Hock School of Public Health, National University of Singapore, Singapore, Singapore
| | - Andrew Fu Wah Ho
- Department of Emergency Medicine, Singapore General Hospital, Singapore, Singapore
- Pre-Hospital and Emergency Research Centre, Duke-NUS Medical School, Singapore, Singapore
| | - Fahad Javaid Siddiqui
- Pre-Hospital and Emergency Research Centre, Duke-NUS Medical School, Singapore, Singapore
| | - Marcus Eng Hock Ong
- Department of Emergency Medicine, Singapore General Hospital, Singapore, Singapore
- Pre-Hospital and Emergency Research Centre, Duke-NUS Medical School, Singapore, Singapore
| | - Nan Liu
- Pre-Hospital and Emergency Research Centre, Duke-NUS Medical School, Singapore, Singapore
- Centre for Quantitative Medicine, Duke-NUS Medical School, Singapore, Singapore
- Institute of Data Science, National University of Singapore, Singapore, Singapore
| |
Collapse
|
3
|
Pham VS, Nguyen A, Dang HB, Le HC, Nguyen MT. Diagnosis of sudden cardiac arrest using principal component analysis in automated external defibrillators. Sci Rep 2023; 13:8768. [PMID: 37253807 DOI: 10.1038/s41598-023-36011-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2022] [Accepted: 05/27/2023] [Indexed: 06/01/2023] Open
Abstract
Sudden cardiac arrest (SCA) consisting of ventricular fibrillation and ventricular tachycardia considered as shockable rhythms is a life-threatening heart disease, which is treated efficiently by the automated external defibrillator (AED). This work proposes a novel design of the SAA, which includes a k-nearest neighbors model and a subset of 8 features extracted from the ECG segments, for the SCA diagnosis on the electrocardiogram (ECG) signal. These features are addressed as the most productive subset among 31 input features based on the evaluation of the feature correlation. The recursive feature elimination algorithm combined with the Boosting model and wise-patient fivefold cross-validation method is adopted for the calculation of the average feature importance, which shows the degree of feature correlation, to construct various input feature subsets. Moreover, component feature combinations known as the representatives of the input feature subsets with an enormous level of correlation and independence are transformed from the input subsets by the principal component analysis method. The wise-patient fivefold cross-validation procedure is used for the evaluation of these component feature combinations on the validation set. The proposed SAA is certainly efficient for SCA detection with a small number of the extracted feature and relatively high diagnosis performance such as accuracy of 99.52%, sensitivity of 97.69%, and specificity of 99.91%.
Collapse
Affiliation(s)
- Van-Su Pham
- Data and intelligent systems laboratory, Posts and Telecommunications Institute of Technology, Hanoi, Vietnam
| | - Anh Nguyen
- Data and intelligent systems laboratory, Posts and Telecommunications Institute of Technology, Hanoi, Vietnam
| | - Hoai Bac Dang
- Posts and Telecommunications Institute of Technology, Hanoi, Vietnam
| | - Hai-Chau Le
- Data and intelligent systems laboratory, Posts and Telecommunications Institute of Technology, Hanoi, Vietnam
| | - Minh Tuan Nguyen
- Data and intelligent systems laboratory, Posts and Telecommunications Institute of Technology, Hanoi, Vietnam.
| |
Collapse
|
4
|
Dong Y, Zhang M, Qiu L, Wang L, Yu Y. An Arrhythmia Classification Model Based on Vision Transformer with Deformable Attention. MICROMACHINES 2023; 14:1155. [PMID: 37374741 PMCID: PMC10302689 DOI: 10.3390/mi14061155] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 05/28/2023] [Accepted: 05/29/2023] [Indexed: 06/29/2023]
Abstract
The electrocardiogram (ECG) is a highly effective non-invasive tool for monitoring heart activity and diagnosing cardiovascular diseases (CVDs). Automatic detection of arrhythmia based on ECG plays a critical role in the early prevention and diagnosis of CVDs. In recent years, numerous studies have focused on using deep learning methods to address arrhythmia classification problems. However, the transformer-based neural network in current research still has a limited performance in detecting arrhythmias for the multi-lead ECG. In this study, we propose an end-to-end multi-label arrhythmia classification model for the 12-lead ECG with varied-length recordings. Our model, called CNN-DVIT, is based on a combination of convolutional neural networks (CNNs) with depthwise separable convolution, and a vision transformer structure with deformable attention. Specifically, we introduce the spatial pyramid pooling layer to accept varied-length ECG signals. Experimental results show that our model achieved an F1 score of 82.9% in CPSC-2018. Notably, our CNN-DVIT outperforms the latest transformer-based ECG classification algorithms. Furthermore, ablation experiments reveal that the deformable multi-head attention and depthwise separable convolution are both efficient in extracting features from multi-lead ECG signals for diagnosis. The CNN-DVIT achieved good performance for the automatic arrhythmia detection of ECG signals. This indicates that our research can assist doctors in clinical ECG analysis, providing important support for the diagnosis of arrhythmia and contributing to the development of computer-aided diagnosis technology.
Collapse
Affiliation(s)
- Yanfang Dong
- School of Biomedical Engineering, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230026, China
- Suzhou Institute of Biomedical Engineering and Technology, China Academy of Sciences, Suzhou 215163, China
| | - Miao Zhang
- Suzhou Institute of Biomedical Engineering and Technology, China Academy of Sciences, Suzhou 215163, China
| | - Lishen Qiu
- School of Biomedical Engineering, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230026, China
| | - Lirong Wang
- Suzhou Institute of Biomedical Engineering and Technology, China Academy of Sciences, Suzhou 215163, China
- School of Electronics and Information Technology, Soochow University, Suzhou 215031, China
| | - Yong Yu
- Suzhou Institute of Biomedical Engineering and Technology, China Academy of Sciences, Suzhou 215163, China
| |
Collapse
|
5
|
Shi J, Li Z, Liu W, Zhang H, Guo Q, Chang S, Wang H, He J, Huang Q. Optimized Solutions of Electrocardiogram Lead and Segment Selection for Cardiovascular Disease Diagnostics. Bioengineering (Basel) 2023; 10:bioengineering10050607. [PMID: 37237677 DOI: 10.3390/bioengineering10050607] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Revised: 05/16/2023] [Accepted: 05/17/2023] [Indexed: 05/28/2023] Open
Abstract
Most of the existing multi-lead electrocardiogram (ECG) detection methods are based on all 12 leads, which undoubtedly results in a large amount of calculation and is not suitable for the application in portable ECG detection systems. Moreover, the influence of different lead and heartbeat segment lengths on the detection is not clear. In this paper, a novel Genetic Algorithm-based ECG Leads and Segment Length Optimization (GA-LSLO) framework is proposed, aiming to automatically select the appropriate leads and input ECG length to achieve optimized cardiovascular disease detection. GA-LSLO extracts the features of each lead under different heartbeat segment lengths through the convolutional neural network and uses the genetic algorithm to automatically select the optimal combination of ECG leads and segment length. In addition, the lead attention module (LAM) is proposed to weight the features of the selected leads, which improves the accuracy of cardiac disease detection. The algorithm is validated on the ECG data from the Huangpu Branch of Shanghai Ninth People's Hospital (defined as the SH database) and the open-source Physikalisch-Technische Bundesanstalt diagnostic ECG database (PTB database). The accuracy for detection of arrhythmia and myocardial infarction under the inter-patient paradigm is 99.65% (95% confidence interval: 99.20-99.76%) and 97.62% (95% confidence interval: 96.80-98.16%), respectively. In addition, ECG detection devices are designed using Raspberry Pi, which verifies the convenience of hardware implementation of the algorithm. In conclusion, the proposed method achieves good cardiovascular disease detection performance. It selects the ECG leads and heartbeat segment length with the lowest algorithm complexity while ensuring classification accuracy, which is suitable for portable ECG detection devices.
Collapse
Affiliation(s)
- Jiguang Shi
- School of Physics and Technology, Wuhan University, Wuhan 430072, China
| | - Zhoutong Li
- Huangpu Branch of Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200011, China
| | - Wenhan Liu
- School of Physics and Technology, Wuhan University, Wuhan 430072, China
| | - Huaicheng Zhang
- School of Physics and Technology, Wuhan University, Wuhan 430072, China
| | - Qianxi Guo
- School of Physics and Technology, Wuhan University, Wuhan 430072, China
| | - Sheng Chang
- School of Physics and Technology, Wuhan University, Wuhan 430072, China
| | - Hao Wang
- School of Physics and Technology, Wuhan University, Wuhan 430072, China
| | - Jin He
- School of Physics and Technology, Wuhan University, Wuhan 430072, China
| | - Qijun Huang
- School of Physics and Technology, Wuhan University, Wuhan 430072, China
| |
Collapse
|
6
|
Krasteva V, Didon JP, Ménétré S, Jekova I. Deep Learning Strategy for Sliding ECG Analysis during Cardiopulmonary Resuscitation: Influence of the Hands-Off Time on Accuracy. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23094500. [PMID: 37177703 PMCID: PMC10181605 DOI: 10.3390/s23094500] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 04/29/2023] [Accepted: 05/03/2023] [Indexed: 05/15/2023]
Abstract
This study aims to present a novel deep learning algorithm for a sliding shock advisory decision during cardiopulmonary resuscitation (CPR) and its performance evaluation as a function of the cumulative hands-off time. We retrospectively used 13,570 CPR episodes from out-of-hospital cardiac arrest (OHCA) interventions reviewed in a period of interest from 30 s before to 10 s after regular analysis of automated external defibrillators (AEDs). Three convolutional neural networks (CNNs) with raw ECG input (duration of 5, 10, and 15 s) were applied for the shock advisory decision during CPR in 26 sequential analyses shifted by 1 s. The start and stop of chest compressions (CC) can occur at arbitrary times in sequential slides; therefore, the sliding hands-off time (sHOT) quantifies the cumulative CC-free portion of the analyzed ECG. An independent test with CPR episodes in 393 ventricular fibrillations (VF), 177 normal sinus rhythms (NSR), 1848 other non-shockable rhythms (ONR), and 3979 asystoles (ASYS) showed a substantial improvement of VF sensitivity when increasing the analysis duration from 5 s to 10 s. Specificity was not dependent on the ECG analysis duration. The 10 s CNN model presented the best performance: 92-94.4% (VF), 92.2-94% (ASYS), 96-97% (ONR), and 98.2-99.5% (NSR) for sliding decision times during CPR; 98-99% (VF), 98.2-99.8% (ASYS), 98.8-99.1 (ONR), and 100% (NSR) for sliding decision times after end of CPR. We identified the importance of sHOT as a reliable predictor of performance, accounting for the minimal sHOT interval of 2-3 s that provides a reliable rhythm detection satisfying the American Heart Association (AHA) standards for AED rhythm analysis. The presented technology for sliding shock advisory decision during CPR achieved substantial performance improvement in short hands-off periods (>2 s), such as insufflations or pre-shock pauses. The performance was competitive despite 1-2.8% point lower ASYS detection during CPR than the standard requirement (95%) for non-noisy ECG signals. The presented deep learning strategy is a basis for improved CPR practices involving both continuous CC and CC with insufflations, associated with minimal CC interruptions for reconfirmation of non-shockable rhythms (minimum hands-off time) and early treatment of VF (minimal pre-shock pauses).
Collapse
Affiliation(s)
- Vessela Krasteva
- Institute of Biophysics and Biomedical Engineering, Bulgarian Academy of Sciences, Acad. G. Bonchev Str. Bl 105, 1113 Sofia, Bulgaria
| | | | - Sarah Ménétré
- Schiller Médical, 4 Rue Louis Pasteur, 67160 Wissembourg, France
| | - Irena Jekova
- Institute of Biophysics and Biomedical Engineering, Bulgarian Academy of Sciences, Acad. G. Bonchev Str. Bl 105, 1113 Sofia, Bulgaria
| |
Collapse
|
7
|
Martínez-Sellés M, Marina-Breysse M. Current and Future Use of Artificial Intelligence in Electrocardiography. J Cardiovasc Dev Dis 2023; 10:jcdd10040175. [PMID: 37103054 PMCID: PMC10145690 DOI: 10.3390/jcdd10040175] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2023] [Revised: 04/14/2023] [Accepted: 04/16/2023] [Indexed: 04/28/2023] Open
Abstract
Artificial intelligence (AI) is increasingly used in electrocardiography (ECG) to assist in diagnosis, stratification, and management. AI algorithms can help clinicians in the following areas: (1) interpretation and detection of arrhythmias, ST-segment changes, QT prolongation, and other ECG abnormalities; (2) risk prediction integrated with or without clinical variables (to predict arrhythmias, sudden cardiac death, stroke, and other cardiovascular events); (3) monitoring ECG signals from cardiac implantable electronic devices and wearable devices in real time and alerting clinicians or patients when significant changes occur according to timing, duration, and situation; (4) signal processing, improving ECG quality and accuracy by removing noise/artifacts/interference, and extracting features not visible to the human eye (heart rate variability, beat-to-beat intervals, wavelet transforms, sample-level resolution, etc.); (5) therapy guidance, assisting in patient selection, optimizing treatments, improving symptom-to-treatment times, and cost effectiveness (earlier activation of code infarction in patients with ST-segment elevation, predicting the response to antiarrhythmic drugs or cardiac implantable devices therapies, reducing the risk of cardiac toxicity, etc.); (6) facilitating the integration of ECG data with other modalities (imaging, genomics, proteomics, biomarkers, etc.). In the future, AI is expected to play an increasingly important role in ECG diagnosis and management, as more data become available and more sophisticated algorithms are developed.
Collapse
Affiliation(s)
- Manuel Martínez-Sellés
- Cardiology Department, Hospital General Universitario Gregorio Marañón, Calle Doctor Esquerdo, 46, 28007 Madrid, Spain
- Centro de Investigación Biomédica en Red-Enfermedades Cardiovasculares (CIBERCV), Instituto de Salud Carlos III, 28029 Madrid, Spain
- Facultad de Ciencias de la Salud, Universidad Europea, Villaviciosa de Odón, 28670 Madrid, Spain
- Facultad de Medicina, Universidad Complutense, 28040 Madrid, Spain
| | - Manuel Marina-Breysse
- Centro de Investigación Biomédica en Red-Enfermedades Cardiovasculares (CIBERCV), Instituto de Salud Carlos III, 28029 Madrid, Spain
- IDOVEN Research, 28013 Madrid, Spain
- Centro Nacional de Investigaciones Cardiovasculares Carlos III (CNIC), Myocardial Pathophysiology Area, 28029 Madrid, Spain
| |
Collapse
|
8
|
Shen CP, Freed BC, Walter DP, Perry JC, Barakat AF, Elashery ARA, Shah KS, Kutty S, McGillion M, Ng FS, Khedraki R, Nayak KR, Rogers JD, Bhavnani SP. Convolution Neural Network Algorithm for Shockable Arrhythmia Classification Within a Digitally Connected Automated External Defibrillator. J Am Heart Assoc 2023; 12:e026974. [PMID: 36942628 DOI: 10.1161/jaha.122.026974] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/23/2023]
Abstract
Background Diagnosis of shockable rhythms leading to defibrillation remains integral to improving out-of-hospital cardiac arrest outcomes. New machine learning techniques have emerged to diagnose arrhythmias on ECGs. In out-of-hospital cardiac arrest, an algorithm within an automated external defibrillator is the major determinant to deliver defibrillation. This study developed and validated the performance of a convolution neural network (CNN) to diagnose shockable arrhythmias within a novel, miniaturized automated external defibrillator. Methods and Results There were 26 464 single-lead ECGs that comprised the study data set. ECGs of 7-s duration were retrospectively adjudicated by 3 physician readers (N=18 total readers). After exclusions (N=1582), ECGs were divided into training (N=23 156), validation (N=721), and test data sets (N=1005). CNN performance to diagnose shockable and nonshockable rhythms was reported with area under the receiver operating characteristic curve analysis, F1, and sensitivity and specificity calculations. The duration for the CNN to output was reported with the algorithm running within the automated external defibrillator. Internal and external validation analyses included CNN performance among arrhythmias, often mistaken for shockable rhythms, and performance among ECGs modified with noise to mimic artifacts. The CNN algorithm achieved an area under the receiver operating characteristic curve of 0.995 (95% CI, 0.990-1.0), sensitivity of 98%, and specificity of 100% to diagnose shockable rhythms. The F1 scores were 0.990 and 0.995 for shockable and nonshockable rhythms, respectively. After input of a 7-s ECG, the CNN generated an output in 383±29 ms (total time of 7.383 s). The CNN outperformed adjudicators in classifying atrial arrhythmias as nonshockable (specificity of 99.3%-98.1%) and was robust against noise artifacts (area under the receiver operating characteristic curve range, 0.871-0.999). Conclusions We demonstrate high diagnostic performance of a CNN algorithm for shockable and nonshockable rhythm arrhythmia classifications within a digitally connected automated external defibrillator. Registration URL: https://clinicaltrials.gov/ct2/show/NCT03662802; Unique identifier: NCT03662802.
Collapse
Affiliation(s)
- Christine P Shen
- Division of Cardiology Healthcare Innovation Laboratory Scripps Clinic San Diego CA
| | | | | | - James C Perry
- University of California San Diego, Rady Children's Hospital San Diego CA
| | - Amr F Barakat
- University of Pittsburg Medical Center Pittsburgh PA
| | | | - Kevin S Shah
- University of Utah Health Sciences Center Salt Lake City UT
| | | | | | - Fu Siong Ng
- Imperial College of London London United Kingdom
| | - Rola Khedraki
- Division of Cardiology Healthcare Innovation Laboratory Scripps Clinic San Diego CA
| | - Keshav R Nayak
- Division of Interventional Cardiology Scripps Mercy Hospital San Diego CA
| | - John D Rogers
- Division of Cardiology Healthcare Innovation Laboratory Scripps Clinic San Diego CA
| | - Sanjeev P Bhavnani
- Division of Cardiology Healthcare Innovation Laboratory Scripps Clinic San Diego CA
| |
Collapse
|
9
|
Zuo F, Dai C, Wei L, Gong Y, Yin C, Li Y. Real-time amplitude spectrum area estimation during chest compression from the ECG waveform using a 1D convolutional neural network. Front Physiol 2023; 14:1113524. [PMID: 37153217 PMCID: PMC10157479 DOI: 10.3389/fphys.2023.1113524] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2022] [Accepted: 04/10/2023] [Indexed: 05/09/2023] Open
Abstract
Introduction: Amplitude spectrum area (AMSA) is a well-established measure than can predict defibrillation outcome and guiding individualized resuscitation of ventricular fibrillation (VF) patients. However, accurate AMSA can only be calculated during cardiopulmonary resuscitation (CPR) pause due to artifacts produced by chest compression (CC). In this study, we developed a real-time AMSA estimation algorithm using a convolutional neural network (CNN). Methods: Data were collected from 698 patients, and the AMSA calculated from the uncorrupted signals served as the true value for both uncorrupted and the adjacent corrupted signals. An architecture consisting of a 6-layer 1D CNN and 3 fully connected layers was developed for AMSA estimation. A 5-fold cross-validation procedure was used to train, validate and optimize the algorithm. An independent testing set comprised of simulated data, real-life CC corrupted data, and preshock data was used to evaluate the performance. Results: The mean absolute error, root mean square error, percentage root mean square difference and correlation coefficient were 2.182/1.951 mVHz, 2.957/2.574 mVHz, 22.887/28.649% and 0.804/0.888 for simulated and real-life testing data, respectively. The area under the receiver operating characteristic curve regarding predicting defibrillation success was 0.835, which was comparable to that of 0.849 using the true value of the AMSA. Conclusions: AMSA can be accurately estimated during uninterrupted CPR using the proposed method.
Collapse
Affiliation(s)
- Feng Zuo
- Department of Biomedical Engineering and Imaging Medicine, Army Medical University, Chongqing, China
| | - Chenxi Dai
- Department of Biomedical Engineering and Imaging Medicine, Army Medical University, Chongqing, China
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing, China
| | - Liang Wei
- Department of Biomedical Engineering and Imaging Medicine, Army Medical University, Chongqing, China
| | - Yushun Gong
- Department of Biomedical Engineering and Imaging Medicine, Army Medical University, Chongqing, China
| | - Changlin Yin
- Department of Intensive Care, Southwest Hospital, Army Medical University, Chongqing, China
| | - Yongqin Li
- Department of Biomedical Engineering and Imaging Medicine, Army Medical University, Chongqing, China
- *Correspondence: Yongqin Li,
| |
Collapse
|
10
|
Lin K, Zhao Y, Kuo JH. Deep learning hybrid predictions for the amount of municipal solid waste: A case study in Shanghai. CHEMOSPHERE 2022; 307:136119. [PMID: 35998731 DOI: 10.1016/j.chemosphere.2022.136119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Revised: 06/06/2022] [Accepted: 08/16/2022] [Indexed: 06/15/2023]
Abstract
It is crucial to precisely estimate the municipal solid waste (MSW) amount for its sustainable management. Owing to learning complicated and abstract features between the factors and target, deep learning has recently emerged as one of the useful tools with potential to predict the MSW amount. Therefore, this study aimed to design an MSW amount predicted system in Shanghai, consisting of Attention (A), one-dimensional convolutional neural network (C), and long short-term memory (L), to investigate the relationship between exogenous series (24 socioeconomics factors and past MSW amount) and target (MSW amount). The role of Attention, 1D-CNN, LSTM played on the MSW predicted amount also have investigated. The results show that attention is crucial for decoding the encoding information, which would improve performance between predicted and known MSW amount (R2 in A-L-C, L-A-C, L-C-A was 89.45%, 90.77%, and 95.31%, respectively.). CNN modules appear to be positioned similarly across the MSW predicted system. Finally, R2 in L-A-C, A-L-C, and A-C-L was 85.44%, 91.61%, and 89.45%, which suggested that LSTM as an intermediary between CNN and Attention modules seems a wise measure to predict the MSW amount based on the correlation efficiency. In addition, some socioeconomic factors including the average number of people in households and budget revenue may be chosen for the decision-making of MSW management in Shanghai city in the future, according to the weight of neurons in fully connected layers by the visual technology.
Collapse
Affiliation(s)
- Kunsen Lin
- The State Key Laboratory of Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Tongji University, 1239 Siping Road, Shanghai, 200092, China.
| | - Youcai Zhao
- The State Key Laboratory of Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Tongji University, 1239 Siping Road, Shanghai, 200092, China
| | - Jia-Hong Kuo
- Department of Safety, Health, and Environmental Engineering, National United University, Miaoli, 36063, Taiwan, ROC.
| |
Collapse
|
11
|
Dong Y, Cai W, Qiu L, Guo Y, Chen Y, Zhang M, Wang D, Zhang H, Wang L. Detection of arrhythmia in 12-lead varied-length ECG using multi-branch signal fusion network. Physiol Meas 2022; 43. [PMID: 35705072 DOI: 10.1088/1361-6579/ac7938] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2022] [Accepted: 06/15/2022] [Indexed: 02/07/2023]
Abstract
Objective.Automatic detection of arrhythmia based on electrocardiogram (ECG) plays a critical role in early prevention and diagnosis of cardiovascular diseases. With the increase in widely available digital ECG data and the development of deep learning, multi-class arrhythmia classification based on automatic feature extraction of ECG has become increasingly attractive. However, the majority of studies cannot accept varied-length ECG signals and have limited performance in detecting multi-class arrhythmias.Approach.In this study, we propose a multi-branch signal fusion network (MBSF-Net) for multi-label classification of arrhythmia in 12-lead varied-length ECG. Our model utilizes the complementary power between different structures, which include Inception with depthwise separable convolution (DWS-Inception), spatial pyramid pooling (SPP) Layer, and multi-scale fusion Resnet (MSF-Resnet). The proposed method can extract features from each lead of 12-lead ECG recordings separately and then effectively fuse the features of each lead by integrating multiple convolution kernels with different receptive fields, which can achieve the information of complementation between different angles of the ECG signal. In particular, our model can accept 12-lead ECG signals of arbitrary length.Main results.The experimental results show that our model achieved an overall classification F1 score of 83.8% in the 12-lead ECG data of CPSC-2018. In addition, the F1 score of the MBSF-Net performed best among the MBF-Nets which are removed the SPP layer from MBSF-Net. In comparison with the latest ECG classification algorithms, the proposed model can be applied in varied-length signals and has an excellent performance, which not only can fully retain the integrity of the original signals, but also eliminates the cropping/padding signal beforehand when dealing with varied-length signal database.Significance.MBSF-Net provides an end-to-end multi-label classification model with outperfom performance, which allows detection of disease in varied-length signals without any additional cropping/padding. Moreover, our research is beneficial to the development of computer-aided diagnosis.
Collapse
Affiliation(s)
- Yanfang Dong
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China,People's Republic of China.,Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Science, People's Republic of China
| | - Wenqiang Cai
- School of Electronics and Information Technology, Soochow University, People's Republic of China
| | - Lishen Qiu
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China,People's Republic of China.,Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Science, People's Republic of China
| | - Yunbo Guo
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Science, People's Republic of China
| | - Yuhang Chen
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China,People's Republic of China
| | - Miao Zhang
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Science, People's Republic of China
| | - Duoduo Wang
- School of Electronics and Information Technology, Soochow University, People's Republic of China
| | - Huimin Zhang
- School of Electronics and Information Technology, Soochow University, People's Republic of China
| | - Lirong Wang
- School of Electronics and Information Technology, Soochow University, People's Republic of China
| |
Collapse
|
12
|
Anbarasi A, Ravi T, Manjula VS, Brindha J, Saranya S, Ramkumar G, Rathi R. A Modified Deep Learning Framework for Arrhythmia Disease Analysis in Medical Imaging Using Electrocardiogram Signal. BIOMED RESEARCH INTERNATIONAL 2022; 2022:5203401. [PMID: 35832849 PMCID: PMC9273451 DOI: 10.1155/2022/5203401] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/25/2022] [Revised: 06/07/2022] [Accepted: 06/16/2022] [Indexed: 12/18/2022]
Abstract
Arrhythmias are anomalies in the heartbeat rhythm that occur occasionally in people's lives. These arrhythmias can lead to potentially deadly consequences, putting your life in jeopardy. As a result, arrhythmia identification and classification are an important aspect of cardiac diagnostics. An electrocardiogram (ECG), a recording collecting the heart's pumping activity, is regarded the guideline for catching these abnormal episodes. Nevertheless, because the ECG contains so much data, extracting the crucial data from imagery evaluation becomes extremely difficult. As a result, it is vital to create an effective system for analyzing ECG's massive amount of data. The ECG image from ECG signal is processed by some image processing techniques. To optimize the identification and categorization process, this research presents a hybrid deep learning-based technique. This paper contributes in two ways. Automating noise reduction and extraction of features, 1D ECG data are first converted into 2D pictures. Then, based on experimental evidence, a hybrid model called CNNLSTM is presented, which combines CNN and LSTM models. We conducted a comprehensive research using the broadly used MIT_BIH arrhythmia dataset to assess the efficacy of the proposed CNN-LSTM technique. The results reveal that the proposed method has a 99.10 percent accuracy rate. Furthermore, the proposed model has an average sensitivity of 98.35 percent and a specificity of 98.38 percent. These outcomes are superior to those produced using other procedures, and they will significantly reduce the amount of involvement necessary by physicians.
Collapse
Affiliation(s)
- A. Anbarasi
- Department of Electronics and Communication Engineering, Sathyabama Institute of Science and Technology, Chennai, 600119 Tamil Nadu, India
| | - T. Ravi
- Department of Electronics and Communication Engineering, Sathyabama Institute of Science and Technology, Chennai, 600119 Tamil Nadu, India
| | - V. S. Manjula
- Department of Computer Science and Engineering, KIoT-College of Informatics, Kombolcha, Wollo University, Ethiopia
| | - J. Brindha
- Department of Electronics and Instrumentation Engineering, Panimalar Engineering College, Chennai, 600123 Tamil Nadu, India
| | - S. Saranya
- Department of Electronics and Communication Engineering, Easwari Engineering College, Ramapuram, Chennai, Tamil Nadu, India
| | - G. Ramkumar
- Department of Electronics and Communication Engineering, Saveetha School of Engineering, SIMATS, Chennai, 602 105 Tamil Nadu, India
| | - R. Rathi
- School of Information Technology and Engineering, Vellore Institute of Technology, Vellore, 632014 Tamil Nadu, India
| |
Collapse
|
13
|
Brown G, Conway S, Ahmad M, Adegbie D, Patel N, Myneni V, Alradhawi M, Kumar N, Obaid DR, Pimenta D, Bray JJH. Role of artificial intelligence in defibrillators: a narrative review. Open Heart 2022; 9:openhrt-2022-001976. [PMID: 35790317 PMCID: PMC9258481 DOI: 10.1136/openhrt-2022-001976] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Accepted: 05/17/2022] [Indexed: 02/01/2023] Open
Abstract
Automated external defibrillators (AEDs) and implantable cardioverter defibrillators (ICDs) are used to treat life-threatening arrhythmias. AEDs and ICDs use shock advice algorithms to classify ECG tracings as shockable or non-shockable rhythms in clinical practice. Machine learning algorithms have recently been assessed for shock decision classification with increasing accuracy. Outside of rhythm classification alone, they have been evaluated in diagnosis of causes of cardiac arrest, prediction of success of defibrillation and rhythm classification without the need to interrupt cardiopulmonary resuscitation. This review explores the many applications of machine learning in AEDs and ICDs. While these technologies are exciting areas of research, there remain limitations to their widespread use including high processing power, cost and the ‘black-box’ phenomenon.
Collapse
Affiliation(s)
- Grace Brown
- Cardiology Department, Royal Free Hospital, London, UK
| | - Samuel Conway
- Cardiology Department, Royal Free Hospital, London, UK
| | - Mahmood Ahmad
- Medical Sciences, University College London, London, UK
| | - Divine Adegbie
- Cardiology Department, East and North Hertfordshire NHS Trust, Stevenage, Hertfordshire, UK
| | - Nishil Patel
- Cardiology Department, North Middlesex University Hospital, London, UK
| | | | | | - Niraj Kumar
- Institute of Cardiovascular Science, University College London, London, UK.,Cardiology Department, Barts Health NHS Trust, London, UK
| | - Daniel R Obaid
- Institute of Life Sciences, Swansea University, Swansea, UK
| | - Dominic Pimenta
- Cardiology Department, Richmond Research Institute, London, UK
| | - Jonathan J H Bray
- Cardiff University College of Biomedical and Life Sciences, Cardiff, UK
| |
Collapse
|
14
|
Petmezas G, Stefanopoulos L, Kilintzis V, Tzavelis A, Rogers JA, Katsaggelos AK, Maglaveras N. State-of-the-art Deep Learning Methods on Electrocardiogram Data: A Systematic Review (Preprint). JMIR Med Inform 2022; 10:e38454. [PMID: 35969441 PMCID: PMC9425174 DOI: 10.2196/38454] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2022] [Revised: 06/03/2022] [Accepted: 07/03/2022] [Indexed: 11/13/2022] Open
Abstract
Background Electrocardiogram (ECG) is one of the most common noninvasive diagnostic tools that can provide useful information regarding a patient’s health status. Deep learning (DL) is an area of intense exploration that leads the way in most attempts to create powerful diagnostic models based on physiological signals. Objective This study aimed to provide a systematic review of DL methods applied to ECG data for various clinical applications. Methods The PubMed search engine was systematically searched by combining “deep learning” and keywords such as “ecg,” “ekg,” “electrocardiogram,” “electrocardiography,” and “electrocardiology.” Irrelevant articles were excluded from the study after screening titles and abstracts, and the remaining articles were further reviewed. The reasons for article exclusion were manuscripts written in any language other than English, absence of ECG data or DL methods involved in the study, and absence of a quantitative evaluation of the proposed approaches. Results We identified 230 relevant articles published between January 2020 and December 2021 and grouped them into 6 distinct medical applications, namely, blood pressure estimation, cardiovascular disease diagnosis, ECG analysis, biometric recognition, sleep analysis, and other clinical analyses. We provide a complete account of the state-of-the-art DL strategies per the field of application, as well as major ECG data sources. We also present open research problems, such as the lack of attempts to address the issue of blood pressure variability in training data sets, and point out potential gaps in the design and implementation of DL models. Conclusions We expect that this review will provide insights into state-of-the-art DL methods applied to ECG data and point to future directions for research on DL to create robust models that can assist medical experts in clinical decision-making.
Collapse
Affiliation(s)
- Georgios Petmezas
- Lab of Computing, Medical Informatics and Biomedical-Imaging Technologies, The Medical School, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Leandros Stefanopoulos
- Lab of Computing, Medical Informatics and Biomedical-Imaging Technologies, The Medical School, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Vassilis Kilintzis
- Lab of Computing, Medical Informatics and Biomedical-Imaging Technologies, The Medical School, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Andreas Tzavelis
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, United States
| | - John A Rogers
- Department of Material Science, Northwestern University, Evanston, IL, United States
| | - Aggelos K Katsaggelos
- Department of Electrical and Computer Engineering, Northwestern University, Evanston, IL, United States
| | - Nicos Maglaveras
- Lab of Computing, Medical Informatics and Biomedical-Imaging Technologies, The Medical School, Aristotle University of Thessaloniki, Thessaloniki, Greece
| |
Collapse
|
15
|
A Hybrid Deep Learning Approach for ECG-Based Arrhythmia Classification. Bioengineering (Basel) 2022; 9:bioengineering9040152. [PMID: 35447712 PMCID: PMC9025942 DOI: 10.3390/bioengineering9040152] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Revised: 03/26/2022] [Accepted: 03/28/2022] [Indexed: 02/07/2023] Open
Abstract
Arrhythmias are defined as irregularities in the heartbeat rhythm, which may infrequently occur in a human’s life. These arrhythmias may cause potentially fatal complications, which may lead to an immediate risk of life. Thus, the detection and classification of arrhythmias is a pertinent issue for cardiac diagnosis. (1) Background: To capture these sporadic events, an electrocardiogram (ECG), a register containing the heart’s electrical function, is considered the gold standard. However, since ECG carries a vast amount of information, it becomes very complex and challenging to extract the relevant information from visual analysis. As a result, designing an efficient (automated) system to analyse the enormous quantity of data possessed by ECG is critical. (2) Method: This paper proposes a hybrid deep learning-based approach to automate the detection and classification process. This paper makes two-fold contributions. First, 1D ECG signals are translated into 2D Scalogram images to automate the noise filtering and feature extraction. Then, based on experimental evidence, by combining two learning models, namely 2D convolutional neural network (CNN) and the Long Short-Term Memory (LSTM) network, a hybrid model called 2D-CNN-LSTM is proposed. (3) Result: To evaluate the efficacy of the proposed 2D-CNN-LSTM approach, we conducted a rigorous experimental study using the widely adopted MIT–BIH arrhythmia database. The obtained results show that the proposed approach provides ≈98.7%, 99%, and 99% accuracy for Cardiac Arrhythmias (ARR), Congestive Heart Failure (CHF), and Normal Sinus Rhythm (NSR), respectively. Moreover, it provides an average sensitivity of the proposed model of 98.33% and a specificity value of 98.35%, for all three arrhythmias. (4) Conclusions: For the classification of arrhythmias, a robust approach has been introduced where 2D scalogram images of ECG signals are trained over the CNN-LSTM model. The results obtained are better as compared to the other existing techniques and will greatly reduce the amount of intervention required by doctors. For future work, the proposed method can be applied over some live ECG signals and Bi-LSTM can be applied instead of LSTM.
Collapse
|
16
|
Nguyen MT, Nguyen THT, Le HC. A review of progress and an advanced method for shock advice algorithms in automated external defibrillators. Biomed Eng Online 2022; 21:22. [PMID: 35366906 PMCID: PMC8976411 DOI: 10.1186/s12938-022-00993-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2021] [Accepted: 03/23/2022] [Indexed: 11/10/2022] Open
Abstract
AbstractShock advice algorithm plays a vital role in the detection of sudden cardiac arrests on electrocardiogram signals and hence, brings about survival improvement by delivering prompt defibrillation. The last decade has witnessed a surge of research efforts in racing for efficient shock advice algorithms, in this context. On one hand, it has been reported that the classification performance of traditional threshold-based methods has not complied with the American Heart Association recommendations. On the other hand, the rise of machine learning and deep learning-based counterparts is paving the new ways for the development of intelligent shock advice algorithms. In this paper, we firstly provide a comprehensive survey on the development of shock advice algorithms for rhythm analysis in automated external defibrillators. Shock advice algorithms are categorized into three groups based on the classification methods in which the detection performance is significantly improved by the use of machine learning and/or deep learning techniques instead of threshold-based approaches. Indeed, in threshold-based shock advice algorithms, a parameter is calculated as a threshold to distinguish shockable rhythms from non-shockable ones. In contrast, machine learning-based methods combine multiple parameters of conventional threshold-based approaches as a set of features to recognize sudden cardiac arrest. Noticeably, those features are possibly extracted from stand-alone ECGs, alternative signals using various decomposition techniques, or fully augmented ECG segments. Moreover, these signals can be also used directly as the input channels of deep learning-based shock advice algorithm designs. Then, we propose an advanced shock advice algorithm using a support vector machine classifier and a feature set extracted from a fully augmented ECG segment with its shockable and non-shockable signals. The relatively high detection performance of the proposed shock advice algorithm implies a potential application for the automated external defibrillator in the practical clinic environment. Finally, we outline several interesting yet challenging research problems for further investigation.
Collapse
|
17
|
Mazumder O, Banerjee R, Roy D, Mukherjee A, Ghose A, Khandelwal S, Sinha A. Computational Model for Therapy Optimization of Wearable Cardioverter Defibrillator: Shockable Rhythm Detection and Optimal Electrotherapy. Front Physiol 2021; 12:787180. [PMID: 34955894 PMCID: PMC8703044 DOI: 10.3389/fphys.2021.787180] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Accepted: 11/08/2021] [Indexed: 11/15/2022] Open
Abstract
Wearable cardioverter defibrillator (WCD) is a life saving, wearable, noninvasive therapeutic device that prevents fatal ventricular arrhythmic propagation that leads to sudden cardiac death (SCD). WCD are frequently prescribed to patients deemed to be at high arrhythmic risk but the underlying pathology is potentially reversible or to those who are awaiting an implantable cardioverter-defibrillator. WCD is programmed to detect appropriate arrhythmic events and generate high energy shock capable of depolarizing the myocardium and thus re-initiating the sinus rhythm. WCD guidelines dictate very high reliability and accuracy to deliver timely and optimal therapy. Computational model-based process validation can verify device performance and benchmark the device setting to suit personalized requirements. In this article, we present a computational pipeline for WCD validation, both in terms of shock classification and shock optimization. For classification, we propose a convolutional neural network-"Long Short Term Memory network (LSTM) full form" (Convolutional neural network- Long short term memory network (CNN-LSTM)) based deep neural architecture for classifying shockable rhythms like Ventricular Fibrillation (VF), Ventricular Tachycardia (VT) vs. other kinds of non-shockable rhythms. The proposed architecture has been evaluated on two open access ECG databases and the classification accuracy achieved is in adherence to American Heart Association standards for WCD. The computational model developed to study optimal electrotherapy response is an in-silico cardiac model integrating cardiac hemodynamics functionality and a 3D volume conductor model encompassing biophysical simulation to compute the effect of shock voltage on myocardial potential distribution. Defibrillation efficacy is simulated for different shocking electrode configurations to assess the best defibrillator outcome with minimal myocardial damage. While the biophysical simulation provides the field distribution through Finite Element Modeling during defibrillation, the hemodynamic module captures the changes in left ventricle functionality during an arrhythmic event. The developed computational model, apart from acting as a device validation test-bed, can also be used for the design and development of personalized WCD vests depending on subject-specific anatomy and pathology.
Collapse
|
18
|
Convolutional squeeze-and-excitation network for ECG arrhythmia detection. Artif Intell Med 2021; 121:102181. [PMID: 34763803 DOI: 10.1016/j.artmed.2021.102181] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Revised: 09/22/2021] [Accepted: 09/22/2021] [Indexed: 11/21/2022]
Abstract
Automatic detection of arrhythmia through an electrocardiogram (ECG) is of great significance for the prevention and treatment of cardiovascular diseases. In Convolutional neural network, the ECG signal is converted into multiple feature channels with equal weights through the convolution operation. Multiple feature channels can provide richer and more comprehensive information, but also contain redundant information, which will affect the diagnosis of arrhythmia, so feature channels that contain arrhythmia information should be paid attention to and given larger weight. In this paper, we introduced the Squeeze-and-Excitation (SE) block for the first time for the automatic detection of multiple types of arrhythmias with ECG. Our algorithm combines the residual convolutional module and the SE block to extract features from the original ECG signal. The SE block adaptively enhances the discriminative features and suppresses noise by explicitly modeling the interdependence between the channels, which can adaptively integrate information from different feature channels of ECG. The one-dimensional convolution operation over the time dimension is used to extract temporal information and the shortcut connection of the Se-Residual convolutional module in the proposed model makes the network easier to optimize. Thanks to the powerful feature extraction capabilities of the network, which can effectively extract discriminative arrhythmia features in multiple feature channels, so that no extra data preprocessing including denoising in other methods are need for our framework. It thus improves the working efficiency and keeps the collected biological information without loss. Experiments conducted with the 12-lead ECG dataset of the China Physiological Signal Challenge (CPSC) 2018 and the dataset of PhysioNet/Computing in Cardiology (CinC) Challenge 2017. The experiment results show that our model gains great performance and has great potential in clinical.
Collapse
|
19
|
Krasteva V, Christov I, Naydenov S, Stoyanov T, Jekova I. Application of Dense Neural Networks for Detection of Atrial Fibrillation and Ranking of Augmented ECG Feature Set. SENSORS (BASEL, SWITZERLAND) 2021; 21:6848. [PMID: 34696061 PMCID: PMC8538849 DOI: 10.3390/s21206848] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Revised: 10/05/2021] [Accepted: 10/13/2021] [Indexed: 11/16/2022]
Abstract
Considering the significant burden to patients and healthcare systems globally related to atrial fibrillation (AF) complications, the early AF diagnosis is of crucial importance. In the view of prominent perspectives for fast and accurate point-of-care arrhythmia detection, our study optimizes an artificial neural network (NN) classifier and ranks the importance of enhanced 137 diagnostic ECG features computed from time and frequency ECG signal representations of short single-lead strips available in 2017 Physionet/CinC Challenge database. Based on hyperparameters' grid search of densely connected NN layers, we derive the optimal topology with three layers and 128, 32, 4 neurons per layer (DenseNet-3@128-32-4), which presents maximal F1-scores for classification of Normal rhythms (0.883, 5076 strips), AF (0.825, 758 strips), Other rhythms (0.705, 2415 strips), Noise (0.618, 279 strips) and total F1 relevant to the CinC Challenge of 0.804, derived by five-fold cross-validation. DenseNet-3@128-32-4 performs equally well with 137 to 32 features and presents tolerable reduction by about 0.03 to 0.06 points for limited input sets, including 8 and 16 features, respectively. The feature reduction is linked to effective application of a comprehensive method for computation of the feature map importance based on the weights of the activated neurons through the total path from input to specific output in DenseNet. The detailed analysis of 20 top-ranked ECG features with greatest importance to the detection of each rhythm and overall of all rhythms reveals DenseNet decision-making process, noticeably corresponding to the cardiologists' diagnostic point of view.
Collapse
Affiliation(s)
- Vessela Krasteva
- Institute of Biophysics and Biomedical Engineering, Bulgarian Academy of Sciences, Acad. G. Bonchev Str. Bl 105, 1113 Sofia, Bulgaria; (V.K.); (I.C.); (T.S.)
| | - Ivaylo Christov
- Institute of Biophysics and Biomedical Engineering, Bulgarian Academy of Sciences, Acad. G. Bonchev Str. Bl 105, 1113 Sofia, Bulgaria; (V.K.); (I.C.); (T.S.)
| | - Stefan Naydenov
- Department of Internal Diseases “Prof. St. Kirkovich”, Medical University of Sofia, 1431 Sofia, Bulgaria;
| | - Todor Stoyanov
- Institute of Biophysics and Biomedical Engineering, Bulgarian Academy of Sciences, Acad. G. Bonchev Str. Bl 105, 1113 Sofia, Bulgaria; (V.K.); (I.C.); (T.S.)
| | - Irena Jekova
- Institute of Biophysics and Biomedical Engineering, Bulgarian Academy of Sciences, Acad. G. Bonchev Str. Bl 105, 1113 Sofia, Bulgaria; (V.K.); (I.C.); (T.S.)
| |
Collapse
|
20
|
Zhu Z, Lan X, Zhao T, Guo Y, Kojodjojo P, Xu Z, Liu Z, Liu S, Wang H, Sun X, Feng M. Identification of 27 abnormalities from multi-lead ECG signals: an ensembled SE_ResNet framework with Sign Loss function. Physiol Meas 2021; 42. [PMID: 34098532 DOI: 10.1088/1361-6579/ac08e6] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2020] [Accepted: 06/07/2021] [Indexed: 11/11/2022]
Abstract
Objective. Cardiovascular disease is a major threat to health and one of the primary causes of death globally. The 12-lead ECG is a cheap and commonly accessible tool to identify cardiac abnormalities. Early and accurate diagnosis will allow early treatment and intervention to prevent severe complications of cardiovascular disease. Our objective is to develop an algorithm that automatically identifies 27 ECG abnormalities from 12-lead ECG databases.Approach. Firstly, a series of pre-processing methods were proposed and applied on various data sources in order to mitigate the problem of data divergence. Secondly, we ensembled two SE_ResNet models and one rule-based model to enhance the performance of various ECG abnormalities' classification. Thirdly, we introduce a Sign Loss to tackle the problem of class imbalance, and thus improve the model's generalizability.Main results. In the PhysioNet/Computing in Cardiology Challenge (2020), our proposed approach achieved a challenge validation score of 0.682, and a full test score of 0.514, placed us 3rd out of 40 in the official ranking.Significance. We proposed an accurate and robust predictive framework that combines deep neural networks and clinical knowledge to automatically classify multiple ECG abnormalities. Our framework is able to identify 27 ECG abnormalities from multi-lead ECG signals regardless of discrepancies in data sources and the imbalance of data labeling. We trained our framework on five datasets and validated it on six datasets from various countries. The outstanding performance demonstrate the effectiveness of our proposed framework.
Collapse
Affiliation(s)
- Zhaowei Zhu
- Ping An Technology, Beijing, People's Republic of China
| | - Xiang Lan
- Saw Swee Hock School of Public Health, National University Health System, National University of Singapore, Singapore
| | - Tingting Zhao
- Ping An Technology, Beijing, People's Republic of China
| | - Yangming Guo
- Ping An Technology, Beijing, People's Republic of China
| | - Pipin Kojodjojo
- Yong Loo Lin School of Medicine, National University Health System, National University of Singapore, Singapore
| | - Zhuoyang Xu
- Ping An Technology, Beijing, People's Republic of China
| | - Zhuo Liu
- Ping An Technology, Beijing, People's Republic of China
| | - Siqi Liu
- NUS Graduate School - Integrative Sciences and Engineering Programme (ISEP), Singapore
| | - Han Wang
- Saw Swee Hock School of Public Health, National University Health System, National University of Singapore, Singapore
| | - Xingzhi Sun
- Ping An Technology, Beijing, People's Republic of China
| | - Mengling Feng
- Saw Swee Hock School of Public Health, National University Health System, National University of Singapore, Singapore.,Institute of Data Science, National University of Singapore, Singapore
| |
Collapse
|
21
|
Optimization of End-to-End Convolutional Neural Networks for Analysis of Out-of-Hospital Cardiac Arrest Rhythms during Cardiopulmonary Resuscitation. SENSORS 2021; 21:s21124105. [PMID: 34203701 PMCID: PMC8232133 DOI: 10.3390/s21124105] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 06/07/2021] [Accepted: 06/10/2021] [Indexed: 02/07/2023]
Abstract
High performance of the shock advisory analysis of the electrocardiogram (ECG) during cardiopulmonary resuscitation (CPR) in out-of-hospital cardiac arrest (OHCA) is important for better management of the resuscitation protocol. It should provide fewer interruptions of chest compressions (CC) for non-shockable organized rhythms (OR) and Asystole, or prompt CC stopping for early treatment of shockable ventricular fibrillation (VF). Major disturbing factors are strong CC artifacts corrupting raw ECG, which we aimed to analyze with optimized end-to-end convolutional neural network (CNN) without pre-filtering or additional sensors. The hyperparameter random search of 1500 CNN models with 2-7 convolutional layers, 5-50 filters and 5-100 kernel sizes was done on large databases from independent OHCA interventions for training (3001 samples) and validation (2528 samples). The best model, named CNN3-CC-ECG network with three convolutional layers (filters@kernels: 5@5,25@20,50@20) presented Sensitivity Se(VF) = 89%(268/301), Specificity Sp(OR) = 91.7%(1504/1640), Sp(Asystole) = 91.1%(3325/3650) on an independent test OHCA database. CNN3-CC-ECG's ability to effectively extract features from raw ECG signals during CPR was comprehensively demonstrated, and the dependency on the CPR corruption level in ECG was tested. We denoted a significant drop of Se(VF) = 74.2% and Sp(OR) = 84.6% in very strong CPR artifacts with a signal-to-noise ratio of SNR < -9 dB, p < 0.05. Otherwise, for strong, moderate and weak CC artifacts (SNR > -9 dB, -6 dB, -3 dB), we observed insignificant performance differences: Se(VF) = 92.5-96.3%, Sp(OR) = 93.4-95.5%, Sp(Asystole) = 92.6-94.0%, p > 0.05. Performance stability with respect to CC rate was validated. Generalizable application of the optimized computationally efficient CNN model was justified by an independent OHCA database, which to our knowledge is the largest test dataset with real-life cardiac arrest rhythms during CPR.
Collapse
|