1
|
Dankovich LJ, Joyner JS, He W, Sesay A, Vaughn-Cooke M. CogWatch: An open-source platform to monitor physiological indicators for cognitive workload and stress. HARDWAREX 2024; 19:e00538. [PMID: 38962730 PMCID: PMC11220525 DOI: 10.1016/j.ohx.2024.e00538] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/04/2024] [Revised: 04/28/2024] [Accepted: 05/14/2024] [Indexed: 07/05/2024]
Abstract
Cognitive workload is a measure of the mental resources a user is dedicating to a given task. Low cognitive workload produces boredom and decreased vigilance, which can lead to an increase in response time. Under high cognitive workload the information processing burden of the user increases significantly, thereby compromising the ability to effectively monitor their environment for unexpected stimuli or respond to emergencies. In cognitive workload and stress monitoring research, sensors are used to measure applicable physiological indicators to infer the state of user. For example, electrocardiography or photoplethysmography are often used to track both the rate at which the heart beats and variability between the individual heart beats. Photoplethysmography and chest straps are also used in studies to track fluctuations in breathing rate. The Galvanic Skin Response is a change in sweat rate (especially on the palms and wrists) and is typically measured by tracking how the resistance of two probes at a fixed distance on the subject's skin changes over time. Finally, fluctuations in Skin Temperature are typically tracked with thermocouples or infrared light (IR) measuring systems in these experiments. While consumer options such a smartwatches for health tracking often have the integrated ability to perform photoplethysmography, they typically perform significant processing on the data which is not transparent to the user and often have a granularity of data that is far too low to be useful for research purposes. It is possible to purchase sensor boards that can be added to Arduino systems, however, these systems generally are very large and obtrusive. Additionally, at the high end of the spectrum there are medical tools used to track these physiological signals, but they are often very expensive and require specific software to be licensed for communication. In this paper, an open-source solution to create a physiological tracker with a wristwatch form factor is presented and validated, using conventional off-the-shelf components. The proposed tool is intended to be applied as a cost-effective solution for research and educational settings.
Collapse
Affiliation(s)
- Louis J. Dankovich
- University of Maryland at College Park, James A. Clark School of Engineering, 8228 Paint Branch Dr, College Park, MD 20742, United States
| | - Janell S. Joyner
- University of Maryland at College Park, James A. Clark School of Engineering, 8228 Paint Branch Dr, College Park, MD 20742, United States
| | - William He
- University of Maryland at College Park, James A. Clark School of Engineering, 8228 Paint Branch Dr, College Park, MD 20742, United States
| | - Ahmad Sesay
- University of Maryland at College Park, James A. Clark School of Engineering, 8228 Paint Branch Dr, College Park, MD 20742, United States
| | - Monifa Vaughn-Cooke
- Virginia Tech, VT Carilion School of Medicine, 2 Riverside Circle, Roanoke, VA 24016, United States
| |
Collapse
|
2
|
Trirongjitmoah S, Promking A, Kaewdang K, Phansiri N, Treeprapin K. Assessing heart rate and blood pressure estimation from image photoplethysmography using a digital blood pressure meter. Heliyon 2024; 10:e27113. [PMID: 38439889 PMCID: PMC10909774 DOI: 10.1016/j.heliyon.2024.e27113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2024] [Revised: 02/20/2024] [Accepted: 02/23/2024] [Indexed: 03/06/2024] Open
Abstract
This study presents a non-contact approach to measuring heart rate and blood pressure using an image photoplethysmography (iPPG) signal, and compares the results to those from an oscillometric blood pressure meter. Facial videos of 100 subjects were recorded via a webcam under ambient lighting conditions to extract iPPG signals. The results revealed a strong correlation between the heart rate derived from iPPG and that obtained from an oscillometric blood pressure meter. In addition, a continuous wavelet transform images with a 6-s duration were used as input for a custom convolutional neural network model, providing the most accurate blood pressure estimation. The proposed method received a grade A for diastolic and grade B for systolic blood pressure based on the British Hypertension Society's criteria. It also met the standards set by the Association for the Advancement of Medical Instrumentation. This non-contact framework shows promising potential for efficient screening purposes.
Collapse
Affiliation(s)
- Suchin Trirongjitmoah
- Department of Electrical and Electronics Engineering, Faculty of Engineering, Ubon Ratchathani University, 85 Sathonlamark, Warinchamrab, Ubon Ratchathani 34190, Thailand
| | - Arphorn Promking
- Department of Electrical and Electronics Engineering, Faculty of Engineering, Ubon Ratchathani University, 85 Sathonlamark, Warinchamrab, Ubon Ratchathani 34190, Thailand
| | - Khanittha Kaewdang
- Department of Electrical and Electronics Engineering, Faculty of Engineering, Ubon Ratchathani University, 85 Sathonlamark, Warinchamrab, Ubon Ratchathani 34190, Thailand
| | - Nisarut Phansiri
- Department of Electrical and Electronics Engineering, Faculty of Engineering, Ubon Ratchathani University, 85 Sathonlamark, Warinchamrab, Ubon Ratchathani 34190, Thailand
| | - Kriengsak Treeprapin
- Department of Mathematics, Statistics and Computers, Faculty of Science, Ubon Ratchathani University, 85 Sathonlamark, Warinchamrab, Ubon Ratchathani 34190, Thailand
| |
Collapse
|
3
|
Pittella E, Testa O, Podestà L, Piuzzi E. An Optical Signal Simulator for the Characterization of Photoplethysmographic Devices. SENSORS (BASEL, SWITZERLAND) 2024; 24:1008. [PMID: 38339729 PMCID: PMC10857427 DOI: 10.3390/s24031008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/29/2023] [Revised: 01/25/2024] [Accepted: 01/31/2024] [Indexed: 02/12/2024]
Abstract
(1) Background: An optical simulator able to provide a repeatable signal with desired characteristics as an input to a photoplethysmographic (PPG) device is presented in order to compare the performance of different PPG devices and also to test the devices with PPG signals available in online databases. (2) Methods: The optical simulator consists of an electronic board containing a photodiode and LEDs at different wavelengths in order to simulate light reflected by the body; the PPG signal taken from the chosen database is reproduced by the electronic board, and the board is used to test a wearable PPG medical device in the form of earbuds. (3) Results: The PPG device response to different average and peak-to-peak signal amplitudes is shown in order to assess the device sensitivity, and the fidelity in tracking the actual heart rate is also investigated. (4) Conclusions: The developed optical simulator promises to be an affordable, flexible, and reliable solution to test PPG devices in the lab, allowing the testing of their actual performances thanks to the possibility of using PPG databases, thus gaining useful and significant information before on-the-field clinical trials.
Collapse
Affiliation(s)
- Erika Pittella
- Department of Information Engineering, Electronics and Telecommunications (DIET), Sapienza University of Rome, 00184 Rome, Italy; (O.T.); (E.P.)
| | - Orlandino Testa
- Department of Information Engineering, Electronics and Telecommunications (DIET), Sapienza University of Rome, 00184 Rome, Italy; (O.T.); (E.P.)
| | - Luca Podestà
- Department of Astronautical, Electrical and Energy Engineering (DIAEE), Sapienza University of Rome, 00184 Rome, Italy;
| | - Emanuele Piuzzi
- Department of Information Engineering, Electronics and Telecommunications (DIET), Sapienza University of Rome, 00184 Rome, Italy; (O.T.); (E.P.)
| |
Collapse
|
4
|
Syversen A, Dosis A, Jayne D, Zhang Z. Wearable Sensors as a Preoperative Assessment Tool: A Review. SENSORS (BASEL, SWITZERLAND) 2024; 24:482. [PMID: 38257579 PMCID: PMC10820534 DOI: 10.3390/s24020482] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2023] [Revised: 01/06/2024] [Accepted: 01/09/2024] [Indexed: 01/24/2024]
Abstract
Surgery is a common first-line treatment for many types of disease, including cancer. Mortality rates after general elective surgery have seen significant decreases whilst postoperative complications remain a frequent occurrence. Preoperative assessment tools are used to support patient risk stratification but do not always provide a precise and accessible assessment. Wearable sensors (WS) provide an accessible alternative that offers continuous monitoring in a non-clinical setting. They have shown consistent uptake across the perioperative period but there has been no review of WS as a preoperative assessment tool. This paper reviews the developments in WS research that have application to the preoperative period. Accelerometers were consistently employed as sensors in research and were frequently combined with photoplethysmography or electrocardiography sensors. Pre-processing methods were discussed and missing data was a common theme; this was dealt with in several ways, commonly by employing an extraction threshold or using imputation techniques. Research rarely processed raw data; commercial devices that employ internal proprietary algorithms with pre-calculated heart rate and step count were most commonly employed limiting further feature extraction. A range of machine learning models were used to predict outcomes including support vector machines, random forests and regression models. No individual model clearly outperformed others. Deep learning proved successful for predicting exercise testing outcomes but only within large sample-size studies. This review outlines the challenges of WS and provides recommendations for future research to develop WS as a viable preoperative assessment tool.
Collapse
Affiliation(s)
- Aron Syversen
- School of Computing, University of Leeds, Leeds LS2 9JT, UK
| | - Alexios Dosis
- School of Medicine, University of Leeds, Leeds LS2 9JT, UK; (A.D.); (D.J.)
| | - David Jayne
- School of Medicine, University of Leeds, Leeds LS2 9JT, UK; (A.D.); (D.J.)
| | - Zhiqiang Zhang
- School of Electrical Engineering, University of Leeds, Leeds LS2 9JT, UK;
| |
Collapse
|
5
|
Vaussenat F, Bhattacharya A, Payette J, Benavides-Guerrero JA, Perrotton A, Gerlein LF, Cloutier SG. Continuous Critical Respiratory Parameter Measurements Using a Single Low-Cost Relative Humidity Sensor: Evaluation Study. JMIR BIOMEDICAL ENGINEERING 2023; 8:e47146. [PMID: 38875670 PMCID: PMC11041423 DOI: 10.2196/47146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Revised: 08/22/2023] [Accepted: 09/07/2023] [Indexed: 06/16/2024] Open
Abstract
BACKGROUND Accurate and portable respiratory parameter measurements are critical for properly managing chronic obstructive pulmonary diseases (COPDs) such as asthma or sleep apnea, as well as controlling ventilation for patients in intensive care units, during surgical procedures, or when using a positive airway pressure device for sleep apnea. OBJECTIVE The purpose of this research is to develop a new nonprescription portable measurement device that utilizes relative humidity sensors (RHS) to accurately measure key respiratory parameters at a cost that is approximately 10 times less than the industry standard. METHODS We present the development, implementation, and assessment of a wearable respiratory measurement device using the commercial Bosch BME280 RHS. In the initial stage, the RHS was connected to the pneumotach (PNT) gold standard device via its external connector to gather breathing metrics. Data collection was facilitated using the Arduino platform with a Bluetooth Low Energy connection, and all measurements were taken in real time without any additional data processing. The device's efficacy was tested with 7 participants (5 men and 2 women), all in good health. In the subsequent phase, we specifically focused on comparing breathing cycle and respiratory rate measurements and determining the tidal volume by calculating the region between inhalation and exhalation peaks. Each participant's data were recorded over a span of 15 minutes. After the experiment, detailed statistical analysis was conducted using ANOVA and Bland-Altman to examine the accuracy and efficiency of our wearable device compared with the traditional methods. RESULTS The perfused air measured with the respiratory monitor enables clinicians to evaluate the absolute value of the tidal volume during ventilation of a patient. In contrast, directly connecting our RHS device to the surgical mask facilitates continuous lung volume monitoring. The results of the 1-way ANOVA showed high P values of .68 for respiratory volume and .89 for respiratory rate, which indicate that the group averages with the PNT standard are equivalent to those with our RHS platform, within the error margins of a typical instrument. Furthermore, analysis utilizing the Bland-Altman statistical method revealed a small bias of 0.03 with limits of agreement (LoAs) of -0.25 and 0.33. The RR bias was 0.018, and the LoAs were -1.89 and 1.89. CONCLUSIONS Based on the encouraging results, we conclude that our proposed design can be a viable, low-cost wearable medical device for pulmonary parametric measurement to prevent and predict the progression of pulmonary diseases. We believe that this will encourage the research community to investigate the application of RHS for monitoring the pulmonary health of individuals.
Collapse
Affiliation(s)
- Fabrice Vaussenat
- Department of Electrical Engineering, École de Technologie Supérieure, Montreal, QC, Canada
| | - Abhiroop Bhattacharya
- Department of Electrical Engineering, École de Technologie Supérieure, Montreal, QC, Canada
| | - Julie Payette
- Department of Electrical Engineering, École de Technologie Supérieure, Montreal, QC, Canada
| | | | - Alexandre Perrotton
- Department of Electrical Engineering, École de Technologie Supérieure, Montreal, QC, Canada
| | - Luis Felipe Gerlein
- Department of Electrical Engineering, École de Technologie Supérieure, Montreal, QC, Canada
| | - Sylvain G Cloutier
- Department of Electrical Engineering, École de Technologie Supérieure, Montreal, QC, Canada
| |
Collapse
|
6
|
Non-Invasive Classification of Blood Glucose Level Based on Photoplethysmography Using Time–Frequency Analysis. INFORMATION 2023. [DOI: 10.3390/info14030145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/25/2023] Open
Abstract
Diabetes monitoring systems are crucial for avoiding potentially significant medical expenses. At this time, the only commercially viable monitoring methods that exist are invasive ones. Since patients are uncomfortable while blood samples are being taken, these techniques have significant disadvantages. The drawbacks of invasive treatments might be overcome by a painless, inexpensive, non-invasive approach to blood glucose level (BGL) monitoring. Photoplethysmography (PPG) signals obtained from sensor leads placed on specific organ tissues are collected using photodiodes and nearby infrared LEDs. Cardiovascular disease can be detected via photoplethysmography. These characteristics can be used to directly affect BGL monitoring in diabetic patients if PPG signals are used. The Guilin People’s Hospital’s open database was used to produce the data collection. The dataset was gathered from 219 adult respondents spanning an age range from 21 to 86 of which 48 percent were male. There were 2100 sampling points total for each PPG data segment. The methodology of feature extraction from data may assist in increasing the effectiveness of classifier training and testing. PPG data information is modified in the frequency domain by the instantaneous frequency (IF) and spectral entropy (SE) moments using the time–frequency (TF) analysis. Three different forms of raw data were used as inputs, and we investigated the original PPG signal, the PPG signal with instantaneous frequency, and the PPG signal with spectral entropy. According to the results of the model testing, the PPG signal with spectral entropy generated the best outcomes. Compared to decision trees, subspace k-nearest neighbor, and k-nearest neighbor, our suggested approach with the super vector machine obtains a greater level of accuracy. The super vector machine, with 91.3% accuracy and a training duration of 9 s, was the best classifier.
Collapse
|
7
|
Photoplethysmography-Based Respiratory Rate Estimation Algorithm for Health Monitoring Applications. J Med Biol Eng 2022; 42:242-252. [PMID: 35535218 PMCID: PMC9056464 DOI: 10.1007/s40846-022-00700-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2021] [Accepted: 03/23/2022] [Indexed: 11/07/2022]
Abstract
Purpose Respiratory rate can provide auxiliary information on the physiological changes within the human body, such as physical and emotional stress. In a clinical setup, the abnormal respiratory rate can be indicative of the deterioration of the patient's condition. Most of the existing algorithms for the estimation of respiratory rate using photoplethysmography (PPG) are sensitive to external noise and may require the selection of certain algorithm-specific parameters, through the trial-and-error method. Methods This paper proposes a new algorithm to estimate the respiratory rate using a photoplethysmography sensor signal for health monitoring. The algorithm is resistant to signal loss and can handle low-quality signals from the sensor. It combines selective windowing, preprocessing and signal conditioning, modified Welch filtering and postprocessing to achieve high accuracy and robustness to noise. Results The Mean Absolute Error and the Root Mean Square Error of the proposed algorithm, with the optimal signal window size, are determined to be 2.05 breaths count per minute and 2.47 breaths count per minute, respectively, when tested on a publicly available dataset. These results present a significant improvement in accuracy over previously reported methods. The proposed algorithm achieved comparable results to the existing algorithms in the literature on the BIDMC dataset (containing data of 53 subjects, each recorded for 8 min) for other signal window sizes. Conclusion The results endorse that integration of the proposed algorithm to a commercially available pulse oximetry device would expand its functionality from the measurement of oxygen saturation level and heart rate to the continuous measurement of the respiratory rate with good efficiency at home and in a clinical setting. Supplementary Information The online version contains supplementary material available at 10.1007/s40846-022-00700-z.
Collapse
|
8
|
Vavrinsky E, Esfahani NE, Hausner M, Kuzma A, Rezo V, Donoval M, Kosnacova H. The Current State of Optical Sensors in Medical Wearables. BIOSENSORS 2022; 12:217. [PMID: 35448277 PMCID: PMC9029995 DOI: 10.3390/bios12040217] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 03/31/2022] [Accepted: 04/04/2022] [Indexed: 05/04/2023]
Abstract
Optical sensors play an increasingly important role in the development of medical diagnostic devices. They can be very widely used to measure the physiology of the human body. Optical methods include PPG, radiation, biochemical, and optical fiber sensors. Optical sensors offer excellent metrological properties, immunity to electromagnetic interference, electrical safety, simple miniaturization, the ability to capture volumes of nanometers, and non-invasive examination. In addition, they are cheap and resistant to water and corrosion. The use of optical sensors can bring better methods of continuous diagnostics in the comfort of the home and the development of telemedicine in the 21st century. This article offers a large overview of optical wearable methods and their modern use with an insight into the future years of technology in this field.
Collapse
Affiliation(s)
- Erik Vavrinsky
- Institute of Electronics and Photonics, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovicova 3, 81219 Bratislava, Slovakia; (N.E.E.); (M.H.); (A.K.); (V.R.); (M.D.)
- Institute of Medical Physics, Biophysics, Informatics and Telemedicine, Faculty of Medicine, Comenius University, Sasinkova 2, 81272 Bratislava, Slovakia
| | - Niloofar Ebrahimzadeh Esfahani
- Institute of Electronics and Photonics, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovicova 3, 81219 Bratislava, Slovakia; (N.E.E.); (M.H.); (A.K.); (V.R.); (M.D.)
| | - Michal Hausner
- Institute of Electronics and Photonics, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovicova 3, 81219 Bratislava, Slovakia; (N.E.E.); (M.H.); (A.K.); (V.R.); (M.D.)
| | - Anton Kuzma
- Institute of Electronics and Photonics, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovicova 3, 81219 Bratislava, Slovakia; (N.E.E.); (M.H.); (A.K.); (V.R.); (M.D.)
| | - Vratislav Rezo
- Institute of Electronics and Photonics, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovicova 3, 81219 Bratislava, Slovakia; (N.E.E.); (M.H.); (A.K.); (V.R.); (M.D.)
| | - Martin Donoval
- Institute of Electronics and Photonics, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovicova 3, 81219 Bratislava, Slovakia; (N.E.E.); (M.H.); (A.K.); (V.R.); (M.D.)
| | - Helena Kosnacova
- Department of Simulation and Virtual Medical Education, Faculty of Medicine, Comenius University, Sasinkova 4, 81272 Bratislava, Slovakia
- Department of Genetics, Cancer Research Institute, Biomedical Research Center, Slovak Academy Sciences, Dubravska Cesta 9, 84505 Bratislava, Slovakia
| |
Collapse
|
9
|
Almarshad MA, Islam MS, Al-Ahmadi S, BaHammam AS. Diagnostic Features and Potential Applications of PPG Signal in Healthcare: A Systematic Review. Healthcare (Basel) 2022; 10:547. [PMID: 35327025 PMCID: PMC8950880 DOI: 10.3390/healthcare10030547] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Revised: 03/03/2022] [Accepted: 03/11/2022] [Indexed: 02/04/2023] Open
Abstract
Recent research indicates that Photoplethysmography (PPG) signals carry more information than oxygen saturation level (SpO2) and can be utilized for affordable, fast, and noninvasive healthcare applications. All these encourage the researchers to estimate its feasibility as an alternative to many expansive, time-wasting, and invasive methods. This systematic review discusses the current literature on diagnostic features of PPG signal and their applications that might present a potential venue to be adapted into many health and fitness aspects of human life. The research methodology is based on the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines 2020. To this aim, papers from 1981 to date are reviewed and categorized in terms of the healthcare application domain. Along with consolidated research areas, recent topics that are growing in popularity are also discovered. We also highlight the potential impact of using PPG signals on an individual's quality of life and public health. The state-of-the-art studies suggest that in the years to come PPG wearables will become pervasive in many fields of medical practices, and the main domains include cardiology, respiratory, neurology, and fitness. Main operation challenges, including performance and robustness obstacles, are identified.
Collapse
Affiliation(s)
- Malak Abdullah Almarshad
- Computer Science Department, College of Computer and Information Sciences, King Saud University, Riyadh 11543, Saudi Arabia; (M.S.I.); (S.A.-A.)
- Computer Science Department, College of Computer and Information Sciences, Al-Imam Mohammad Ibn Saud Islamic University, Riyadh 11432, Saudi Arabia
| | - Md Saiful Islam
- Computer Science Department, College of Computer and Information Sciences, King Saud University, Riyadh 11543, Saudi Arabia; (M.S.I.); (S.A.-A.)
| | - Saad Al-Ahmadi
- Computer Science Department, College of Computer and Information Sciences, King Saud University, Riyadh 11543, Saudi Arabia; (M.S.I.); (S.A.-A.)
| | - Ahmed S. BaHammam
- The University Sleep Disorders Center, Department of Medicine, College of Medicine, King Saud University, Riyadh 11324, Saudi Arabia;
| |
Collapse
|
10
|
Li W, Chen Z. Breathing rate estimation based on multiple linear regression. Comput Methods Biomech Biomed Engin 2021; 25:772-782. [PMID: 34514914 DOI: 10.1080/10255842.2021.1977801] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
The breathing rate is a key clinical parameter that can now be estimated using photoplethysmographic methods. Here, we present an indirect method of breathing rate estimation that does not require bulky and uncomfortable sensors. Breathing modulates a pulsed wave; we extracted the maximum and minimum values, and first-order derivatives thereof, to measure breathing amplitude, frequency, and baseline drift. Demodulation was used to obtain multiple breathing waveforms, from which peak values are extracted to obtain breathing rates. Multiple linear regression was used to combine the breathing rates of different feature points. We used a breathing dataset for 53 subjects, and divided the data into training and test sets when calculating the regression coefficients. We also assessed the generalizability of our linear model. We found that breathing rate estimation was more accurate when using a multivariate signal method with multiple versus a single feature point. The mean absolute error, mean error, and standard deviation of the error were 1.28, -0.07, and 1.60 breaths per minute, respectively.
Collapse
Affiliation(s)
- Wenbo Li
- Research Institute of Electronic Science and Technology, University of Electronic Science and Technology of China, Chengdu, China
| | - Ziyang Chen
- Research Institute of Electronic Science and Technology, University of Electronic Science and Technology of China, Chengdu, China
| |
Collapse
|