1
|
Şen M, Oğuz M, Avcı İ. Non-toxic flexible screen-printed MWCNT-based electrodes for non-invasive biomedical applications. Talanta 2024; 268:125341. [PMID: 37931570 DOI: 10.1016/j.talanta.2023.125341] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Revised: 10/20/2023] [Accepted: 10/23/2023] [Indexed: 11/08/2023]
Abstract
Here, a non-toxic, flexible, low-cost, and disposable multiwalled carbon nanotube (MWCNT)-based screen-printed electrode (SPE) was developed for non-invasive health monitoring applications. A novel MWCNT-based conductive paste formulation was prepared and optimized for printing SPEs using a computer numerical control (CNC)-made stencil. The electrodes were electrochemically characterized and subjected to physical stress to investigate their mechanical durability in extreme situations such as heavy exercise. The reproducibility of the fabrication approach and the stability of the electrodes were also demonstrated. The electrochemical performance of the electrodes was tested with first dopamine (DA) and then glucose. The SPE displayed a linear response in the DA concentration range of 5-500 μM with a limit-of-detection (LOD) of 0.87 μM. Detection of glucose was carried out based on electrochemical-enzymatic redox cycling in artificial sweat; wherein the flexible SPE-based biosensor exhibited a linear response, particularly up to 1 mM with an LOD of 31.7 μM. It is likely that the high sensitivity was achieved due to the large surface-to-volume ratio of MWCNTs and micro/nanoporous network morphology of the electrode surface which was observed in scanning electron microscopy (SEM). Cytotoxicity tests confirmed that the flexible MWCNT-SPEs are non-toxic and therefore safe for non-invasive health monitoring. As a result, the electrodes displayed excellent electrochemical behavior and are expected to contribute to wearable sensor technology due to features such as high stability, sensitivity, flexibility, and non-toxicity.
Collapse
Affiliation(s)
- Mustafa Şen
- Department of Biomedical Engineering, Izmir Katip Celebi University, Izmir, Turkey.
| | - Merve Oğuz
- Department of Biomedical Engineering Graduate Program, Izmir Katip Celebi University, Izmir, Turkey
| | - İpek Avcı
- Department of Biomedical Engineering Graduate Program, Izmir Katip Celebi University, Izmir, Turkey
| |
Collapse
|
2
|
Ciobotaru IC, Oprea D, Ciobotaru CC, Enache TA. Low-Cost Plant-Based Metal and Metal Oxide Nanoparticle Synthesis and Their Use in Optical and Electrochemical (Bio)Sensors. BIOSENSORS 2023; 13:1031. [PMID: 38131791 PMCID: PMC10741781 DOI: 10.3390/bios13121031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Revised: 12/06/2023] [Accepted: 12/13/2023] [Indexed: 12/23/2023]
Abstract
Technological progress has led to the development of analytical tools that promise a huge socio-economic impact on our daily lives and an improved quality of life for all. The use of plant extract synthesized nanoparticles in the development and fabrication of optical or electrochemical (bio)sensors presents major advantages. Besides their low-cost fabrication and scalability, these nanoparticles may have a dual role, serving as a transducer component and as a recognition element, the latter requiring their functionalization with specific components. Different approaches, such as surface modification techniques to facilitate precise biomolecule attachment, thereby augmenting recognition capabilities, or fine tuning functional groups on nanoparticle surfaces are preferred for ensuring stable biomolecule conjugation while preserving bioactivity. Size optimization, maximizing surface area, and tailored nanoparticle shapes increase the potential for robust interactions and enhance the transduction. This article specifically aims to illustrate the adaptability and effectiveness of these biosensing platforms in identifying precise biological targets along with their far-reaching implications across various domains, spanning healthcare diagnostics, environmental monitoring, and diverse bioanalytical fields. By exploring these applications, the article highlights the significance of prioritizing the use of natural resources for nanoparticle synthesis. This emphasis aligns with the worldwide goal of envisioning sustainable and customized biosensing solutions, emphasizing heightened sensitivity and selectivity.
Collapse
Affiliation(s)
- Iulia Corina Ciobotaru
- National Institute of Materials Physics, 405A Atomistilor, 077125 Magurele, Romania; (I.C.C.); (D.O.); (C.C.C.)
| | - Daniela Oprea
- National Institute of Materials Physics, 405A Atomistilor, 077125 Magurele, Romania; (I.C.C.); (D.O.); (C.C.C.)
- Faculty of Physics, University of Bucharest, 405 Atomistilor, 077125 Magurele, Romania
| | | | - Teodor Adrian Enache
- National Institute of Materials Physics, 405A Atomistilor, 077125 Magurele, Romania; (I.C.C.); (D.O.); (C.C.C.)
| |
Collapse
|
3
|
Zhang H, Yu Y, Li Y, Lin L, Zhang C, Zhang W, Wang L, Niu L. A novel BC/g-C 3N 4 porous hydrogel carrier used in intimately coupled photocatalysis and biodegradation system for efficient removal of tetracycline hydrochloride in water. CHEMOSPHERE 2023; 317:137888. [PMID: 36657568 DOI: 10.1016/j.chemosphere.2023.137888] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Revised: 01/05/2023] [Accepted: 01/14/2023] [Indexed: 06/17/2023]
Abstract
Intimately coupled photocatalysis and biodegradation (ICPB) is a promising technology to remove refractory contaminants from water. The key to successful ICPB is a carrier capable of accumulating biofilm and adhering photocatalyst firmly. Herein, BC/g-C3N4 was prepared into a three dimensional porous hydrogel and used as a carrier in ICPB system for the first time. Degradation experiments revealed that the removal rate of tetracycline hydrochloride (TCH) in water by the ICPB system was 96.0% after 10 h, which was significantly higher than that by the photocatalysis (PC, 76.3%), biodegradation (B, 32.5%), adsorption (AD, 17.2%), and photolysis (P, 5.0%) systems. Photo-electrochemical tests confirmed that ICPB system had superior electron transfer ability between photocatalysts and microorganisms. The removal efficiency of COD proved that microorganisms played an important role in the mineralization process of TCH by the ICPB system. After the ICPB degradation experiment, microorganisms maintained high activity and Pseudomonas, Burkholderiaceae and Flavobacterium which had TCH degradation or electron transport ability, were enriched. In conclusion, the novel ICPB carrier overcame shortcomings of the traditional ICPB carrier and the novel ICPB system had superior degradation performance for TCH. This study provided a possible method to promote the practical application of ICPB technology.
Collapse
Affiliation(s)
- Huanjun Zhang
- Key Laboratory of Integrated Regulation and Resource Development of Shallow Lakes, Ministry of Education, College of Environment, Hohai University, Xikang Road #1, Nanjing, 210098, PR China
| | - Yanan Yu
- Key Laboratory of Integrated Regulation and Resource Development of Shallow Lakes, Ministry of Education, College of Environment, Hohai University, Xikang Road #1, Nanjing, 210098, PR China
| | - Yi Li
- Key Laboratory of Integrated Regulation and Resource Development of Shallow Lakes, Ministry of Education, College of Environment, Hohai University, Xikang Road #1, Nanjing, 210098, PR China.
| | - Li Lin
- Basin Water Environmental Research Department, Changjiang River Scientific Research Institute, Wuhan, Hubei, 430010, PR China; Key Lab of Basin Water Resource and Eco-Environmental Science in Hubei Province, Wuhan, Hubei, 430010, PR China.
| | - Chi Zhang
- Key Laboratory of Integrated Regulation and Resource Development of Shallow Lakes, Ministry of Education, College of Environment, Hohai University, Xikang Road #1, Nanjing, 210098, PR China
| | - Wenlong Zhang
- Key Laboratory of Integrated Regulation and Resource Development of Shallow Lakes, Ministry of Education, College of Environment, Hohai University, Xikang Road #1, Nanjing, 210098, PR China
| | - Longfei Wang
- Key Laboratory of Integrated Regulation and Resource Development of Shallow Lakes, Ministry of Education, College of Environment, Hohai University, Xikang Road #1, Nanjing, 210098, PR China
| | - Lihua Niu
- Key Laboratory of Integrated Regulation and Resource Development of Shallow Lakes, Ministry of Education, College of Environment, Hohai University, Xikang Road #1, Nanjing, 210098, PR China
| |
Collapse
|
4
|
Wongsa C, Udomsom S, Budwong A, Kiwfo K, Grudpan K, Paengnakorn P. Sequential Injection Amperometric System Coupling with Bioreactor for In-Line Glucose Monitoring in Cell Culture Application. MOLECULES (BASEL, SWITZERLAND) 2022; 27:molecules27196665. [PMID: 36235202 PMCID: PMC9573359 DOI: 10.3390/molecules27196665] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/17/2022] [Revised: 09/28/2022] [Accepted: 10/04/2022] [Indexed: 11/05/2022]
Abstract
We proposed a specially designed sequential injection (SI) amperometric system coupling with a bioreactor for in-line glucose monitoring in cell culture. The system is composed of three main parts which are the bioreactor, SI system, and electrochemical detection unit. The bioreactor accommodates six individual cell culture units which can be operated separately under different conditions. The SI system enables automatic in-line sampling and in-line sample dilution, with a specially designed mixing unit; therefore, it has the benefits of fast analysis time and less contamination risk. The use of 3D-printed microfluidic components, a mixing channel, and a flow cell helped to reduce operational time and sample volume. A disposable screen-printed electrode (SPE), modified with glucose oxidase (GOD), carbon nanotube, and gold nanoparticle, was used for detection. The developed system provided a linear range up to 3.8 mM glucose in cell culture media. In order to work with cell culture in higher glucose media, the in-line sample dilution can be applied. The developed SI system was demonstrated with mouse fibroblast (L929) cell culture. The results show that glucose concentration obtained from the SI system is comparable with that obtained from the conventional colorimetric method. This work can be further developed and applied for in vitro cell-based experiments in biomedical research.
Collapse
Affiliation(s)
- Chanyanut Wongsa
- Biomedical Engineering Institute, Chiang Mai University, Chiang Mai 50200, Thailand
| | - Suruk Udomsom
- Biomedical Engineering Institute, Chiang Mai University, Chiang Mai 50200, Thailand
| | - Apiwat Budwong
- Biomedical Engineering Institute, Chiang Mai University, Chiang Mai 50200, Thailand
| | - Kanokwan Kiwfo
- Center of Excellence for Innovation in Analytical Science and Technology for Biodiversity-Based Economic and Society (I-ANALY-S-T_B.BES-CMU), Chiang Mai University, Chiang Mai 50200, Thailand
| | - Kate Grudpan
- Center of Excellence for Innovation in Analytical Science and Technology for Biodiversity-Based Economic and Society (I-ANALY-S-T_B.BES-CMU), Chiang Mai University, Chiang Mai 50200, Thailand
- Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand
| | - Pathinan Paengnakorn
- Biomedical Engineering Institute, Chiang Mai University, Chiang Mai 50200, Thailand
- Center of Excellence for Innovation in Analytical Science and Technology for Biodiversity-Based Economic and Society (I-ANALY-S-T_B.BES-CMU), Chiang Mai University, Chiang Mai 50200, Thailand
- Correspondence:
| |
Collapse
|