Jiang J, Tang F, He S, Dong F, Liu S. Vibration Analysis of Porous Cu-Si Microcantilever Beams in Fluids Based on Modified Couple Stress Theory. NANOMATERIALS (BASEL, SWITZERLAND) 2024; 14:1144. [PMID: 38998749 PMCID: PMC11243555 DOI: 10.3390/nano14131144] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2024] [Revised: 06/29/2024] [Accepted: 06/30/2024] [Indexed: 07/14/2024]
Abstract
The vibrations in functionally graded porous Cu-Si microcantilever beams are investigated based on physical neutral plane theory, modified coupled stress theory, and scale distribution theory (MCST&SDT). Porous microcantilever beams define four pore distributions. Considering the physical neutral plane theory, the material properties of the beams are computed through four different power-law distributions. The material properties of microcantilever beams are corrected by scale effects based on modified coupled stress theory. Considering the fluid driving force, the amplitude-frequency response spectra and resonant frequencies of the porous microcantilever beam in three different fluids are obtained based on the Euler-Bernoulli beam theory. The quality factors of porous microcantilever beams in three different fluids are derived by estimating the equation. The computational analysis shows that the presence of pores in microcantilever beams leads to a decrease in Young's modulus. Different pore distributions affect the material properties to different degrees. The gain effect of the scale effect is weakened, but the one-dimensional temperature field and amplitude-frequency response spectra show an increasing trend. The quality factor is decreased by porosity, and the degree of influence of porosity increases as the beam thickness increases. The gradient factor n has a greater effect on the resonant frequency. The effect of porosity on the resonant frequency is negatively correlated when the gradient factor is small (n<1) but positively correlated when the gradient factor is large (n>1).
Collapse
Affiliation(s)
- Jize Jiang
- Key Laboratory of Transients in Hydraulic Machinery, Ministry of Education, School of Power and Mechanical Engineering, Wuhan University, Wuhan 430072, China
| | - Feixiang Tang
- Key Laboratory of Transients in Hydraulic Machinery, Ministry of Education, School of Power and Mechanical Engineering, Wuhan University, Wuhan 430072, China
| | - Siyu He
- China-EU Insititute for Clean and Renewable Energy, Huazhong University of Science & Technology, Wuhan 430074, China
| | - Fang Dong
- The Institute of Technological Sciences, Wuhan University, Wuhan 430072, China
| | - Sheng Liu
- Key Laboratory of Transients in Hydraulic Machinery, Ministry of Education, School of Power and Mechanical Engineering, Wuhan University, Wuhan 430072, China
- The Institute of Technological Sciences, Wuhan University, Wuhan 430072, China
| |
Collapse
|
2
|
Nsubuga L, Duggen L, Balzer F, Høegh S, Marcondes TL, Greenbank W, Rubahn HG, de Oliveira Hansen R. Modeling Nonlinear Dynamics of Functionalization Layers: Enhancing Gas Sensor Sensitivity for Piezoelectrically Driven Microcantilever. ACS Sens 2024; 9:1842-1856. [PMID: 38619068 DOI: 10.1021/acssensors.3c02393] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/16/2024]
Abstract
This article presents a parametrized response model that enhances the limit of detection (LOD) of piezoelectrically driven microcantilever (PD-MC) based gas sensors by accounting for the adsorption-induced variations in elastic properties of the functionalization layer (binder) and the nonlinear motional dynamics of the PD-MC. The developed model is demonstrated for quantifying cadaverine, a volatile biogenic diamine whose concentration is used to assess the freshness of meat. At low concentrations of cadaverine, an increase in the resonance frequency is observed, contrary to the expected reduction due to mass added by adsorption. The study explores the variations in the elastic modulus vis-à-vis the adsorbed mass of cadaverine and derives the resonance frequency to the adsorbed mass response function. We advance a blended technique involving the analysis of atomic force microscopy (AFM) force-distance (f-d) curves and fitting of the quartz crystal microbalance (QCM) impedance response spectrum to deduce the adsorption-induced changes in the viscoelastic properties of the functionalization layer. The findings obtained are subsequently employed in modeling the response function for a structurally nonhomogenous PD-MC, highlighting the significance of the functionalization layer to the global elastic properties. The structural composition of the PD-MC beam adopted herein features a trapezoidal base hosting the actuating piezoelectric stratum and a rectangular free end with a functionalization layer. The Euler-Bernoulli beam theory coupled with Hamilton's principle is used to develop the equation of motion, which is subsequently discretized into a set of nonlinear ordinary differential equations via Galerkin expansion, and the solutions to the first fundamental mode of vibration are determined using the method of multiple scales. The obtained solutions provide a basis for deducing the nonlinear response function model to the adsorbed mass. The derived model is validated by recorded resonance frequency changes resulting from exposure to known concentrations of cadaverine. We demonstrate that the increase in resonance frequency for low concentrations of cadaverine is due to the dominance of the variation of the elastic modulus of the functionalization layer originating from the initial binder-analyte interactions over damping due to added mass. It is concluded that the developed nonlinear response function model can reliably be used to quantify the cadaverine concentration at low concentrations with an elevated Limit of Detection.
Collapse
Affiliation(s)
- Lawrence Nsubuga
- SDU NanoSYD, Mads Clausen Institute, University of Southern Denmark, Alsion 2, 6400 Sønderborg, Denmark
| | - Lars Duggen
- SDU Mechatronics, Department of Mechanical and Electrical Engineering, University of Southern Denmark, Alsion 2, 6400 Sønderborg, Denmark
| | - Frank Balzer
- SDU Centre for Photonics Engineering, Mads Clausen Institute, University of Southern Denmark, Alsion 2, 6400 Sønderborg, Denmark
| | - Simon Høegh
- AmiNIC ApS, Jernbanegade 75, 5500 Middelfart, Denmark
| | - Tatiana L Marcondes
- SDU NanoSYD, Mads Clausen Institute, University of Southern Denmark, Alsion 2, 6400 Sønderborg, Denmark
| | - William Greenbank
- SDU Centre for Industrial Electronics, University of Southern Denmark, Alsion 2, 6400 Sønderborg, Denmark
| | - Horst-Günter Rubahn
- SDU NanoSYD, Mads Clausen Institute, University of Southern Denmark, Alsion 2, 6400 Sønderborg, Denmark
| | - Roana de Oliveira Hansen
- SDU NanoSYD, Mads Clausen Institute, University of Southern Denmark, Alsion 2, 6400 Sønderborg, Denmark
| |
Collapse
|
3
|
Saxena A, Kumar M, Mishra D, Singh K. Optimization of Newtonian fluid pressure in microcantilever integrated flexible microfluidic channel for healthcare application. Biomed Phys Eng Express 2024; 10:035015. [PMID: 38452735 DOI: 10.1088/2057-1976/ad3187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Accepted: 03/07/2024] [Indexed: 03/09/2024]
Abstract
The demand for microfluidic pressure sensors is ever-increasing in various industries due to their crucial role in controlling fluid pressure within microchannels. While syringe pump setups have been traditionally used to regulate fluid pressure in microfluidic devices, they often result in larger setups that increase the cost of the device. To address this challenge and miniaturize the syringe pump setup, the researcher introduced integrated T-microcantilever-based microfluidic devices. In these devices, microcantilevers are incorporated, and their deflections correlate with the microchannel's pressure. When the relative pressure of fluid (plasma) changes, the T-microcantilever deflects, and the extent of this deflection provides information on fluid pressure within the microchannel. In this work, finite element method (FEM) based simulation was carried out to investigate the role of material, and geometric parameters of the cantilever, and the fluid viscosity on the pressure sensing capability of the T-microcantilever integrated microfluidic channel. The T-microcantilever achieves a maximum deflection of 127μm at a 5000μm/s velocity for Young's modulus(E) of 360 kPa of PDMS by employing a hinged structure. On the other hand, a minimum deflection of 4.05 × 10-5μm was attained at 5000μm/s for Young's modulus of 1 TPa for silicon. The maximum deflected angle of the T-cantilever is 20.46° for a 360 kPa Young's modulus while the minimum deflection angle of the T-cantilever is measured at 13.77° for 900 KPa at a fluid velocity of 5000μm s-1. The T-cantilever functions as a built-in microchannel that gauges the fluid pressure within the microchannel. The peak pressure, set at 8.86 Pa on the surface of the cantilever leads to a maximum deflection of 0.096μm (approximately 1μm) in the T-cantilever at a 1:1 velocity ratio. An optimized microfluidic device embedded with microchannels can optimize fluid pressure in a microchannel support cell separation.
Collapse
Affiliation(s)
- Ankur Saxena
- Department of Electronics and Communication Engineering, Manipal University Jaipur, Jaipur-303007, Rajasthan, India
- FlexMEMS Research Centre (FMRC), Manipal University Jaipur, Jaipur-303007, Rajasthan, India
| | - Mahesh Kumar
- Department of Computer Science and Engineering, Graphic Era Deemed to be University Dehradun, Dehradun-248001, Uttarakhand, India
| | - Dhaneshwar Mishra
- Department of Mechanical Engineering, Manipal University Jaipur, Jaipur-303007, Rajasthan, India
- Multiscale Simulation Research Center (MSRC), Manipal University Jaipur, Jaipur--303007, Rajasthan, India
| | - Kulwant Singh
- Department of Electronics and Communication Engineering, Manipal University Jaipur, Jaipur-303007, Rajasthan, India
- FlexMEMS Research Centre (FMRC), Manipal University Jaipur, Jaipur-303007, Rajasthan, India
- Skill Faculty of Engineering & Technology, Shri Vishwakarma Skill University, Palwal, Haryana 121102, India
| |
Collapse
|
4
|
Muñoz-Galán H, Alemán C, Pérez-Madrigal MM. Beyond biology: alternative uses of cantilever-based technologies. LAB ON A CHIP 2023; 23:1128-1150. [PMID: 36636915 DOI: 10.1039/d2lc00873d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Micromechanical cantilever sensors are attracting a lot of attention because of the need for characterizing, detecting, and monitoring chemical and physical properties, as well as compounds at the nanoscale. The fields of application of micro-cantilever sensors span from biological and point-of-care, to military or industrial sectors. The purpose of this work focuses on thermal and mechanical characterization, environmental monitoring, and chemical detection, in order to provide a technical review of the most recent technical advances and applications, as well as the future prospective of micro-cantilever sensor research.
Collapse
Affiliation(s)
- Helena Muñoz-Galán
- Departament d'Enginyeria Química, Campus Diagonal Besòs (EEBE), Universitat Politècnica de Catalunya, C/Eduard Maristany, 10-14, 08019 Barcelona, Spain.
- Barcelona Research Center for Multiscale Science and Engineering, Campus Diagonal Besòs (EEBE), Universitat Politècnica de Catalunya, C/Eduard Maristany, 10-14, 08019 Barcelona, Spain
| | - Carlos Alemán
- Departament d'Enginyeria Química, Campus Diagonal Besòs (EEBE), Universitat Politècnica de Catalunya, C/Eduard Maristany, 10-14, 08019 Barcelona, Spain.
- Barcelona Research Center for Multiscale Science and Engineering, Campus Diagonal Besòs (EEBE), Universitat Politècnica de Catalunya, C/Eduard Maristany, 10-14, 08019 Barcelona, Spain
- Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology, Baldiri Reixac 10-12, 08028 Barcelona, Spain
| | - Maria M Pérez-Madrigal
- Departament d'Enginyeria Química, Campus Diagonal Besòs (EEBE), Universitat Politècnica de Catalunya, C/Eduard Maristany, 10-14, 08019 Barcelona, Spain.
- Barcelona Research Center for Multiscale Science and Engineering, Campus Diagonal Besòs (EEBE), Universitat Politècnica de Catalunya, C/Eduard Maristany, 10-14, 08019 Barcelona, Spain
| |
Collapse
|
5
|
Ba Hashwan SS, Khir MHM, Nawi IM, Ahmad MR, Hanif M, Zahoor F, Al-Douri Y, Algamili AS, Bature UI, Alabsi SS, Sabbea MOB, Junaid M. A review of piezoelectric MEMS sensors and actuators for gas detection application. NANOSCALE RESEARCH LETTERS 2023; 18:25. [PMID: 36847870 DOI: 10.1186/s11671-023-03779-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/17/2022] [Accepted: 01/25/2023] [Indexed: 05/24/2023]
Abstract
Piezoelectric microelectromechanical system (piezo-MEMS)-based mass sensors including the piezoelectric microcantilevers, surface acoustic waves (SAW), quartz crystal microbalance (QCM), piezoelectric micromachined ultrasonic transducer (PMUT), and film bulk acoustic wave resonators (FBAR) are highlighted as suitable candidates for highly sensitive gas detection application. This paper presents the piezo-MEMS gas sensors' characteristics such as their miniaturized structure, the capability of integration with readout circuit, and fabrication feasibility using multiuser technologies. The development of the piezoelectric MEMS gas sensors is investigated for the application of low-level concentration gas molecules detection. In this work, the various types of gas sensors based on piezoelectricity are investigated extensively including their operating principle, besides their material parameters as well as the critical design parameters, the device structures, and their sensing materials including the polymers, carbon, metal-organic framework, and graphene.
Collapse
Affiliation(s)
- Saeed S Ba Hashwan
- Department of Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, 32610, Seri Iskandar, Malaysia.
| | - Mohd Haris Md Khir
- Department of Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, 32610, Seri Iskandar, Malaysia
| | - Illani Mohd Nawi
- Department of Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, 32610, Seri Iskandar, Malaysia
| | - Mohamad Radzi Ahmad
- Department of Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, 32610, Seri Iskandar, Malaysia
| | - Mehwish Hanif
- Department of Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, 32610, Seri Iskandar, Malaysia
| | - Furqan Zahoor
- Department of Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, 32610, Seri Iskandar, Malaysia
| | - Y Al-Douri
- Nanotechnology and Catalysis Research Centre (NANOCAT), University of Malaya, Kuala Lumpur, Malaysia
- Department of Mechanical Engineering, Faculty of Engineering, Piri Reis University, Eflatun Sk. No: 8, 34940, Tuzla, Istanbul, Turkey
- Department of Applied Science and Astronomy, College of Sciences, University of Sharjah, Sharjah, United Arab Emirates
| | - Abdullah Saleh Algamili
- Department of Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, 32610, Seri Iskandar, Malaysia
| | - Usman Isyaku Bature
- Department of Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, 32610, Seri Iskandar, Malaysia
| | - Sami Sultan Alabsi
- Department of Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, 32610, Seri Iskandar, Malaysia
| | - Mohammed O Ba Sabbea
- Department of Electrical and Computer Engineering, University of Waterloo, Waterloo, ON, N2L 3G1, Canada
| | - Muhammad Junaid
- Department of Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, 32610, Seri Iskandar, Malaysia
- Department of Electronic Engineering, Balochistan University of Information Technology, Engineering and Management Sciences, Quetta, 87300, Pakistan
| |
Collapse
|
6
|
Zhang H, Yang S, Zeng J, Li X, Chuai R. A Genosensor Based on the Modification of a Microcantilever: A Review. MICROMACHINES 2023; 14:427. [PMID: 36838127 PMCID: PMC9959632 DOI: 10.3390/mi14020427] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/27/2022] [Revised: 12/28/2022] [Accepted: 01/06/2023] [Indexed: 06/18/2023]
Abstract
When the free end of a microcantilever is modified by a genetic probe, this sensor can be used for a wider range of applications, such as for chemical analysis, biological testing, pharmaceutical screening, and environmental monitoring. In this paper, to clarify the preparation and detection process of a microcantilever sensor with genetic probe modification, the core procedures, such as probe immobilization, complementary hybridization, and signal extraction and processing, are combined and compared. Then, to reveal the microcantilever's detection mechanism and analysis, the influencing factors of testing results, the theoretical research, including the deflection principle, the establishment and verification of a detection model, as well as environmental influencing factors are summarized. Next, to demonstrate the application results of the genetic-probe-modified sensors, based on the classification of detection targets, the application status of other substances except nucleic acid, virus, bacteria and cells is not introduced. Finally, by enumerating the application results of a genetic-probe-modified microcantilever combined with a microfluidic chip, the future development direction of this technology is surveyed. It is hoped that this review will contribute to the future design of a genetic-probe-modified microcantilever, with further exploration of the sensitive mechanism, optimization of the design and processing methods, expansion of the application fields, and promotion of practical application.
Collapse
Affiliation(s)
- He Zhang
- Correspondence: ; Tel.: +86-024-2549-6401
| | | | | | | | | |
Collapse
|
7
|
Incaviglia I, Herzog S, Fläschner G, Strohmeyer N, Tosoratti E, Müller DJ. Tailoring the Sensitivity of Microcantilevers To Monitor the Mass of Single Adherent Living Cells. NANO LETTERS 2023; 23:588-596. [PMID: 36607826 PMCID: PMC9881155 DOI: 10.1021/acs.nanolett.2c04198] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Revised: 12/19/2022] [Indexed: 06/17/2023]
Abstract
Microcantilevers are widely employed as mass sensors for biological samples, from single molecules to single cells. However, the accurate mass quantification of living adherent cells is impaired by the microcantilever's mass sensitivity and cell migration, both of which can lead to detect masses mismatching by ≫50%. Here, we design photothermally actuated microcantilevers to optimize the accuracy of cell mass measurements. By reducing the inertial mass of the microcantilever using a focused ion beam, we considerably increase its mass sensitivity, which is validated by finite element analysis and experimentally by gelatin microbeads. The improved microcantilevers allow us to instantly monitor at much improved accuracy the mass of both living HeLa cells and mouse fibroblasts adhering to different substrates. Finally, we show that the improved cantilever design favorably restricts cell migration and thus reduces the large measurement errors associated with this effect.
Collapse
Affiliation(s)
- Ilaria Incaviglia
- Department
of Biosystems Science and Engineering, Swiss
Federal Institute of Technology Zurich (ETH), Basel4058, Switzerland
| | - Sophie Herzog
- Department
of Biosystems Science and Engineering, Swiss
Federal Institute of Technology Zurich (ETH), Basel4058, Switzerland
| | - Gotthold Fläschner
- Department
of Biosystems Science and Engineering, Swiss
Federal Institute of Technology Zurich (ETH), Basel4058, Switzerland
- Nanosurf
AG, Liestal4410, Switzerland
| | - Nico Strohmeyer
- Department
of Biosystems Science and Engineering, Swiss
Federal Institute of Technology Zurich (ETH), Basel4058, Switzerland
| | - Enrico Tosoratti
- Department
of Mechanical and Process Engineering, Swiss
Federal Institute of Technology Zurich (ETH), Zürich8092, Switzerland
| | - Daniel J. Müller
- Department
of Biosystems Science and Engineering, Swiss
Federal Institute of Technology Zurich (ETH), Basel4058, Switzerland
| |
Collapse
|
8
|
Nsubuga L, Duggen L, Marcondes TL, Høegh S, Lofink F, Meyer J, Rubahn HG, de Oliveira Hansen R. Gas Adsorption Response of Piezoelectrically Driven Microcantilever Beam Gas Sensors: Analytical, Numerical, and Experimental Characterizations. SENSORS (BASEL, SWITZERLAND) 2023; 23:1093. [PMID: 36772134 PMCID: PMC9921292 DOI: 10.3390/s23031093] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Revised: 01/11/2023] [Accepted: 01/12/2023] [Indexed: 06/18/2023]
Abstract
This work presents an approach for the estimation of the adsorbed mass of 1,5-diaminopentane (cadaverine) on a functionalized piezoelectrically driven microcantilever (PD-MC) sensor, using a polynomial developed from the characterization of the resonance frequency response to the known added mass. This work supplements the previous studies we carried out on the development of an electronic nose for the measurement of cadaverine in meat and fish, as a determinant of its freshness. An analytical transverse vibration analysis of a chosen microcantilever beam with given dimensions and desired resonance frequency (>10 kHz) was conducted. Since the beam is considered stepped with both geometrical and material non-uniformity, a modal solution for stepped beams, extendable to clamped-free beams of any shape and structure, is derived and used for free and forced vibration analyses of the beam. The forced vibration analysis is then used for transformation to an equivalent electrical model, to address the fact that the microcantilever is both electronically actuated and read. An analytical resonance frequency response to the mass added is obtained by adding simulated masses to the free end of the beam. Experimental verification of the resonance frequency response is carried out, by applying known masses to the microcantilever while measuring the resonance frequency response using an impedance analyzer. The obtained response is then transformed into a resonance frequency to the added mass response polynomial using a polynomial fit. The resulting polynomial is then verified for performance using different masses of cantilever functionalization solution. The functionalized cantilever is then exposed to different concentrations of cadaverine while measuring the resonance frequency and mass of cadaverine adsorbed estimated using the previously obtained polynomial. The result is that there is the possibility of using this approach to estimate the mass of cadaverine gas adsorbed on a functionalized microcantilever, but the effectiveness of this approach is highly dependent on the known masses used for the development of the response polynomial model.
Collapse
Affiliation(s)
- Lawrence Nsubuga
- SDU NanoSYD, Mads Clausen Institute, University of Southern Denmark, Alsion 2, 6400 Sønderborg, Denmark
| | - Lars Duggen
- SDU Mechatronics, Department of Mechanical and Electrical Engineering, University of Southern Denmark, Alsion 2, 6400 Sønderborg, Denmark
| | | | - Simon Høegh
- AmiNIC ApS, Jernbanegade 75, 5500 Middlefart, Denmark
| | - Fabian Lofink
- Fraunhofer Institute for Silicon Technology, Fraunhoferstraße 1, 25524 Itzehoe, Germany
| | - Jana Meyer
- Fraunhofer Institute for Silicon Technology, Fraunhoferstraße 1, 25524 Itzehoe, Germany
| | - Horst-Günter Rubahn
- SDU NanoSYD, Mads Clausen Institute, University of Southern Denmark, Alsion 2, 6400 Sønderborg, Denmark
| | - Roana de Oliveira Hansen
- SDU NanoSYD, Mads Clausen Institute, University of Southern Denmark, Alsion 2, 6400 Sønderborg, Denmark
| |
Collapse
|
9
|
Vogl L, Schweizer P, Denninger P, Richter G, Spiecker E. Sensing Capabilities of Single Nanowires Studied with Correlative In Situ Light and Electron Microscopy. ACS NANO 2022; 16:18110-18118. [PMID: 36282103 PMCID: PMC9706674 DOI: 10.1021/acsnano.2c04848] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Accepted: 10/05/2022] [Indexed: 06/16/2023]
Abstract
Modern devices based on modular designs require versatile and universal sensor components which provide an efficient, sensitive, and compact measurement unit. To improve the space capacity of devices, miniaturized building elements are needed, which implies a turning away from conventional microcantilevers toward nanoscale cantilevers. Nanowires can be seen as high-quality resonators and offer the opportunity to create sensing devices on small scales. To use such a one-dimensional nanostructure as a resonant cantilever, a precise characterization based on the fundamental properties is needed. We present a correlative electron and light microscopy approach to characterize the pressure and environment sensing capabilities of single nanowires by analyzing their resonance behavior in situ. The high vacuum in electron microscopes enables the characterization of the intrinsic vibrational properties and the maximum quality factor. To analyze the damping effect caused by the interaction of the gas molecules with the excited nanowire, the in situ resonance measurements have been performed under non-high-vacuum conditions. For this purpose, single nanowires are mounted in a specifically designed compact gas chamber underneath the light microscope, which enables direct observation of the resonance behavior and evaluation of the quality factor with dependence of the applied gas atmosphere (He, N2, Ar, Air) and pressure level. By using the resonance vibration, we demonstrate the pressure sensing capability of a single nanowire and examine the molar mass of the surrounding atmosphere. Together this shows that even single nanowires can be utilized as versatile nanoscale gas sensors.
Collapse
Affiliation(s)
- Lilian
M. Vogl
- Institute
of Micro- and Nanostructure Research (IMN), Center for Nanoanalysis
and Electron Microscopy (CENEM), Interdisciplinary Center for Nanostructured
Films (IZNF), Friedrich-Alexander-Universität
Erlangen-Nürnberg, 91058 Erlangen, Germany
| | - Peter Schweizer
- Institute
of Micro- and Nanostructure Research (IMN), Center for Nanoanalysis
and Electron Microscopy (CENEM), Interdisciplinary Center for Nanostructured
Films (IZNF), Friedrich-Alexander-Universität
Erlangen-Nürnberg, 91058 Erlangen, Germany
| | - Peter Denninger
- Institute
of Micro- and Nanostructure Research (IMN), Center for Nanoanalysis
and Electron Microscopy (CENEM), Interdisciplinary Center for Nanostructured
Films (IZNF), Friedrich-Alexander-Universität
Erlangen-Nürnberg, 91058 Erlangen, Germany
| | - Gunther Richter
- Max Planck Institute for Intelligent Systems, 70569 Stuttgart, Germany
| | - Erdmann Spiecker
- Institute
of Micro- and Nanostructure Research (IMN), Center for Nanoanalysis
and Electron Microscopy (CENEM), Interdisciplinary Center for Nanostructured
Films (IZNF), Friedrich-Alexander-Universität
Erlangen-Nürnberg, 91058 Erlangen, Germany
| |
Collapse
|
10
|
Mouro J, Paoletti P, Sartore M, Vassalli M, Tiribilli B. Photothermal Self-Excitation of a Phase-Controlled Microcantilever for Viscosity or Viscoelasticity Sensing. SENSORS (BASEL, SWITZERLAND) 2022; 22:8421. [PMID: 36366122 PMCID: PMC9659050 DOI: 10.3390/s22218421] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Revised: 10/28/2022] [Accepted: 10/30/2022] [Indexed: 06/16/2023]
Abstract
This work presents a feedback closed-loop platform to be used for viscosity or viscoelasticity sensing of Newtonian or non-Newtonian fluids. The system consists of a photothermally excited microcantilever working in a digital Phase-Locked Loop, in which the phase between the excitation signal to the cantilever and the reference demodulating signals is chosen and imposed in the loop. General analytical models to describe the frequency and amplitude of oscillation of the cantilever immersed in viscous and viscoelastic fluids are derived and validated against experiments. In particular, the sensitivity of the sensor to variations of viscosity of Newtonian fluids, or to variations of elastic/viscous modulus of non-Newtonian fluids, are studied. Interestingly, it is demonstrated the possibility of controlling the sensitivity of the system to variations of these parameters by choosing the appropriate imposed phase in the loop. A working point with maximum sensitivity can be used for real-time detection of small changes of rheological parameters with low-noise and fast-transient response. Conversely, a working point with zero sensitivity to variations of rheological parameters can be potentially used to decouple the effect of simultaneous external factors acting on the resonator.
Collapse
Affiliation(s)
- João Mouro
- Institute for Complex Systems, National Research Council (ISC-CNR), 50019 Florence, Italy
| | - Paolo Paoletti
- School of Engineering, University of Liverpool, Liverpool L69 3GH, UK
| | | | - Massimo Vassalli
- School of Engineering, University of Glasgow, Glasgow G12 8LT, UK
| | - Bruno Tiribilli
- Institute for Complex Systems, National Research Council (ISC-CNR), 50019 Florence, Italy
| |
Collapse
|
11
|
G. Saiz P, Fernández de Luis R, Lasheras A, Arriortua MI, Lopes AC. Magnetoelastic Resonance Sensors: Principles, Applications, and Perspectives. ACS Sens 2022; 7:1248-1268. [PMID: 35452212 DOI: 10.1021/acssensors.2c00032] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Magnetoelastic resonators are gaining attention as an incredibly versatile and sensitive transduction platform for the detection of varied physical, chemical, and biological parameters. These sensors, based on the coupling effect between mechanical and magnetic properties of ME platforms, stand out in comparison to alternative technologies due to their low cost and wireless detection capability. Several parameters have been optimized over the years to improve their performance, such as their composition, surface functionalization, or shape geometry. In this review, the working principles, recent advances, and future perspectives of magnetoelastic resonance transducers are introduced, highlighting their potentials as a versatile platform for sensing applications. First, the fundamental principles governing the magnetoelastic resonators performance are introduced as well as the most common magnetoelastic materials and their main fabrication methods are described. Second, the versatility and technical feasibility of magnetoelastic resonators for biological, chemical, and physical sensing are highlighted and the most recent results and functionalization processes are summarized. Finally, the forefront advances to further improve the performance of magnetoelastic resonators for sensing applications have been identified.
Collapse
Affiliation(s)
- Paula G. Saiz
- BCMaterials, Basque Center for Materials, Applications and Nanostructures, UPV/EHU Science Park, 48940, Leioa, Spain
- Department of Geology, Science and Technology Faculty, University of the Basque Country (UPV/EHU), Barrio Sarriena s/n, 48940, Leioa, Spain
| | - Roberto Fernández de Luis
- BCMaterials, Basque Center for Materials, Applications and Nanostructures, UPV/EHU Science Park, 48940, Leioa, Spain
| | - Andoni Lasheras
- Department of Physics, Science and Technology Faculty, University of the Basque Country (UPV/EHU), Barrio Sarriena s/n, 48940, Leioa, Spain
| | - María Isabel Arriortua
- BCMaterials, Basque Center for Materials, Applications and Nanostructures, UPV/EHU Science Park, 48940, Leioa, Spain
- Department of Geology, Science and Technology Faculty, University of the Basque Country (UPV/EHU), Barrio Sarriena s/n, 48940, Leioa, Spain
| | - Ana Catarina Lopes
- Macromolecular Chemistry Group (LABQUIMAC), Department of Physical Chemistry, Faculty of Science and Technology, University of the Basque Country (UPV/EHU), Barrio Sarriena, s/n, 48940, Leioa, Spain
- Centre for Cooperative Research on Alternative Energies (CIC energiGUNE), Basque Research and Technology Alliance (BRTA), Alava Technology Park, Albert Einstein 48, 01510, Vitoria-Gasteiz, Spain
- IKERBASQUE, Basque Foundation for Science, Plaza Euskadi 5, 48009, Bilbao, Spain
| |
Collapse
|
12
|
Gas-Sensing Properties of a Carbyne-Enriched Nanocoating Deposited onto Surface Acoustic Wave Composite Substrates with Various Electrode Topologies. CRYSTALS 2022. [DOI: 10.3390/cryst12040501] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
The application of carbyne-enriched nanomaterials opens unique possibilities for enhancing the functional properties of several nanomaterials and unlocking their full potential for practical applications in high-end devices. We studied the ethanol-vapor-sensing performance of a carbyne-enriched nanocoating deposited onto surface acoustic wave (SAW) composite substrates with various electrode topologies. The carbyne-enriched nanocoating was grown using the ion-assisted pulse-plasma deposition technique. Such carbon nanostructured metamaterials were named 2D-ordered linear-chain carbon, where they represented a two-dimensionally packed hexagonal array of carbon chains held by the van der Waals forces, with the interchain spacing approximately being between 4.8 and 5.03 Å. The main characteristics of the sensing device, such as dynamic range, linearity, sensitivity, and response and recovery times, were measured as a function of the ethanol concentration. To the authors’ knowledge, this was the first time demonstration of the detection ability of carbyne-enriched material to ethanol vapors. The results may pave the path for optimization of these sensor architectures for the precise detection of volatile organic compounds, with applications in the fields of medicine, healthcare, and air composition monitoring.
Collapse
|
13
|
Mouro J, Paoletti P, Basso M, Tiribilli B. Measuring Viscosity Using the Hysteresis of the Non-Linear Response of a Self-Excited Cantilever. SENSORS 2021; 21:s21165592. [PMID: 34451036 PMCID: PMC8402250 DOI: 10.3390/s21165592] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/13/2021] [Revised: 08/09/2021] [Accepted: 08/17/2021] [Indexed: 12/14/2022]
Abstract
A self-oscillating microcantilever in a feedback loop comprised of a gain, a saturator, and an adjustable phase-shifter is used to measure the viscosity of Newtonian fluids. Shifting the signal of the loop with the adjustable phase-shifter causes sudden jumps in the oscillation frequency of the cantilever. The exact position of these jumps depends on whether the shift imposed by the phase-shifter is increasing or decreasing and, therefore, the self-excited cantilever exhibits a hysteretic non-linear response. This response was studied and the system modeled by a delay differential equation of motion where frequency-dependent added mass and damping terms accounted for the density and the viscosity of the medium. Experimental data were obtained for solutions with different concentrations of glycerol in water and used to validate the model. Two distinct sensing modalities were proposed for this system: the sweeping mode, where the width of the observed hysteresis depends on the viscosity of the medium, and the threshold mode, where a sudden jump of the oscillation frequency is triggered by an arbitrarily small change in the viscosity of the medium.
Collapse
Affiliation(s)
- João Mouro
- Institute for Complex Systems, National Research Council (ISC-CNR), 50019 Florence, Italy;
- Correspondence:
| | - Paolo Paoletti
- School of Engineering, University of Liverpool, Liverpool L69 3GH, UK;
| | - Michele Basso
- Department of Information Engineering, University of Florence, 50139 Florence, Italy;
| | - Bruno Tiribilli
- Institute for Complex Systems, National Research Council (ISC-CNR), 50019 Florence, Italy;
| |
Collapse
|
14
|
Bertke M, Kirsch I, Uhde E, Peiner E. Ultrafine Aerosol Particle Sizer Based on Piezoresistive Microcantilever Resonators with Integrated Air-Flow Channel. SENSORS (BASEL, SWITZERLAND) 2021; 21:3731. [PMID: 34072041 PMCID: PMC8199094 DOI: 10.3390/s21113731] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Revised: 05/21/2021] [Accepted: 05/24/2021] [Indexed: 01/11/2023]
Abstract
To monitor airborne nano-sized particles (NPs), a single-chip differential mobility particle sizer (DMPS) based on resonant micro cantilevers in defined micro-fluidic channels (µFCs) is introduced. A size bin of the positive-charged fraction of particles herein is separated from the air stream by aligning their trajectories onto the cantilever under the action of a perpendicular electrostatic field of variable strength. We use previously described µFCs and piezoresistive micro cantilevers (PMCs) of 16 ng mass fabricated using micro electro mechanical system (MEMS) technology, which offer a limit of detection of captured particle mass of 0.26 pg and a minimum detectable particulate mass concentration in air of 0.75 µg/m3. Mobility sizing in 4 bins of a nebulized carbon aerosol NPs is demonstrated based on finite element modelling (FEM) combined with a-priori knowledge of particle charge state. Good agreement of better than 14% of mass concentration is observed in a chamber test for the novel MEMS-DMPS vs. a simultaneously operated standard fast mobility particle sizer (FMPS) as reference instrument. Refreshing of polluted cantilevers is feasible without de-mounting the sensor chip from its package by multiply purging them alternately in acetone steam and clean air.
Collapse
Affiliation(s)
- Maik Bertke
- Institute for Semiconductor Technology and Laboratory for Emerging Nanometrology (LENA), Technische Universität Braunschweig, Hans-Sommer-Str. 66/Langer Kamp 6a, 38106 Braunschweig, Germany;
| | - Ina Kirsch
- Fraunhofer Wilhelm-Klauditz-Institut (WKI), Bienroder Weg 54E, 38106 Braunschweig, Germany; (I.K.); (E.U.)
| | - Erik Uhde
- Fraunhofer Wilhelm-Klauditz-Institut (WKI), Bienroder Weg 54E, 38106 Braunschweig, Germany; (I.K.); (E.U.)
| | - Erwin Peiner
- Institute for Semiconductor Technology and Laboratory for Emerging Nanometrology (LENA), Technische Universität Braunschweig, Hans-Sommer-Str. 66/Langer Kamp 6a, 38106 Braunschweig, Germany;
| |
Collapse
|
15
|
Direct Scaling of Measure on Vortex Shedding through a Flapping Flag Device in the Open Channel around a Cylinder at Re∼10 3: Taylor's Law Approach. SENSORS 2021; 21:s21051871. [PMID: 33800140 PMCID: PMC7962443 DOI: 10.3390/s21051871] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/13/2021] [Revised: 02/17/2021] [Accepted: 03/03/2021] [Indexed: 11/18/2022]
Abstract
The problem of vortex shedding, which occurs when an obstacle is placed in a regular flow, is governed by Reynolds and Strouhal numbers, known by dimensional analysis. The present work aims to propose a thin films-based device, consisting of an elastic piezoelectric flapping flag clamped at one end, in order to determine the frequency of vortex shedding downstream an obstacle for a flow field at Reynolds number Re∼103 in the open channel. For these values, Strouhal number obtained in such way is in accordance with the results known in literature. Moreover, the development of the voltage over time, generated by the flapping flag under the load due to flow field, shows a highly fluctuating behavior and satisfies Taylor’s law, observed in several complex systems. This provided useful information about the flow field through the constitutive law of the device.
Collapse
|
16
|
Di Pasquale G, Graziani S, Kurukunda S, Pollicino A, Trigona C. Investigation on the Role of Ionic Liquids in the Output Signal Produced by Bacterial Cellulose-Based Mechanoelectrical Transducers. SENSORS 2021; 21:s21041295. [PMID: 33670269 PMCID: PMC7918817 DOI: 10.3390/s21041295] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/18/2021] [Revised: 02/04/2021] [Accepted: 02/08/2021] [Indexed: 12/17/2022]
Abstract
Green sensors are required for the realization of a sustainable economy. Biopolymer-derived composites are a meaningful solution to such a needing. Bacterial Cellulose (BC) is a green biopolymer, with significant mechanical and electrical properties. BC-based composites have been proposed to realize generating mechanoelectrical transductors. The transductors consist of a sheet of BC, impregnated of Ionic Liquids (ILs), and covered with two layers of Conducting Polymer (CP) as the electrodes. Charges accumulate at the electrodes when the transductor is bent. Generating sensors can produce either Open Circuit (OC) voltage or Short Circuit (SC) current. In the paper, the OC voltage and SC current, generated from BC-based composites, in a cantilever configuration and subjected to dynamic deformation are compared. The influence of ILs in the transduction performance, both in the case of OC voltage and SC current is investigated. Experimental investigations of structural, chemical, and mechanoelectrical transduction properties, when the composite is dynamically bent, are performed. The mechanoelectrical investigation has been carried on both in the time and in the frequency domains. Reported results show that no relevant changes can be obtained because of the use of IL when the OC voltage is considered. On the contrary, dramatic changes are observed for the case of SC current, whose value increases by about two orders of magnitude.
Collapse
Affiliation(s)
- Giovanna Di Pasquale
- Dipartimento di Scienze Chimiche (DSC), University of Catania, Viale Andrea Doria 6, 95125 Catania, Italy;
| | - Salvatore Graziani
- Dipartimento di Ingegneria Elettrica Elettronica e Informatica (DIEEI), University of Catania, Viale Andrea Doria 6, 95125 Catania, Italy; (S.K.); (C.T.)
- Correspondence:
| | - Santhosh Kurukunda
- Dipartimento di Ingegneria Elettrica Elettronica e Informatica (DIEEI), University of Catania, Viale Andrea Doria 6, 95125 Catania, Italy; (S.K.); (C.T.)
| | - Antonino Pollicino
- Dipartimento di Ingegneria Civile e Architettura (DICAr), University of Catania, Viale Andrea Doria 6, 95125 Catania, Italy;
| | - Carlo Trigona
- Dipartimento di Ingegneria Elettrica Elettronica e Informatica (DIEEI), University of Catania, Viale Andrea Doria 6, 95125 Catania, Italy; (S.K.); (C.T.)
| |
Collapse
|