1
|
Lagopati N, Valamvanos TF, Proutsou V, Karachalios K, Pippa N, Gatou MA, Vagena IA, Cela S, Pavlatou EA, Gazouli M, Efstathopoulos E. The Role of Nano-Sensors in Breath Analysis for Early and Non-Invasive Disease Diagnosis. CHEMOSENSORS 2023; 11:317. [DOI: 10.3390/chemosensors11060317] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/11/2023]
Abstract
Early-stage, precise disease diagnosis and treatment has been a crucial topic of scientific discussion since time immemorial. When these factors are combined with experience and scientific knowledge, they can benefit not only the patient, but also, by extension, the entire health system. The development of rapidly growing novel technologies allows for accurate diagnosis and treatment of disease. Nanomedicine can contribute to exhaled breath analysis (EBA) for disease diagnosis, providing nanomaterials and improving sensing performance and detection sensitivity. Through EBA, gas-based nano-sensors might be applied for the detection of various essential diseases, since some of their metabolic products are detectable and measurable in the exhaled breath. The design and development of innovative nanomaterial-based sensor devices for the detection of specific biomarkers in breath samples has emerged as a promising research field for the non-invasive accurate diagnosis of several diseases. EBA would be an inexpensive and widely available commercial tool that could also be used as a disease self-test kit. Thus, it could guide patients to the proper specialty, bypassing those expensive tests, resulting, hence, in earlier diagnosis, treatment, and thus a better quality of life. In this review, some of the most prevalent types of sensors used in breath-sample analysis are presented in parallel with the common diseases that might be diagnosed through EBA, highlighting the impact of incorporating new technological achievements in the clinical routine.
Collapse
Affiliation(s)
- Nefeli Lagopati
- Laboratory of Biology, Department of Basic Medical Sciences, Medical School, National and Kapodistrian University of Athens, 11527 Athens, Greece
- Biomedical Research Foundation, Academy of Athens, 11527 Athens, Greece
| | - Theodoros-Filippos Valamvanos
- Laboratory of Biology, Department of Basic Medical Sciences, Medical School, National and Kapodistrian University of Athens, 11527 Athens, Greece
- Medical Physics Unit, 2nd Department of Radiology, Medical School, National and Kapodistrian University of Athens, Attikon University Hospital, 12462 Athens, Greece
| | - Vaia Proutsou
- Laboratory of Biology, Department of Basic Medical Sciences, Medical School, National and Kapodistrian University of Athens, 11527 Athens, Greece
- Medical Physics Unit, 2nd Department of Radiology, Medical School, National and Kapodistrian University of Athens, Attikon University Hospital, 12462 Athens, Greece
| | - Konstantinos Karachalios
- Laboratory of Biology, Department of Basic Medical Sciences, Medical School, National and Kapodistrian University of Athens, 11527 Athens, Greece
- Medical Physics Unit, 2nd Department of Radiology, Medical School, National and Kapodistrian University of Athens, Attikon University Hospital, 12462 Athens, Greece
| | - Natassa Pippa
- Section of Pharmaceutical Technology, Department of Pharmacy, School of Health Sciences, National and Kapodistrian University of Athens, 15771 Athens, Greece
| | - Maria-Anna Gatou
- Laboratory of General Chemistry, School of Chemical Engineering, National Technical University of Athens, Zografou Campus, 15772 Athens, Greece
| | - Ioanna-Aglaia Vagena
- Laboratory of Biology, Department of Basic Medical Sciences, Medical School, National and Kapodistrian University of Athens, 11527 Athens, Greece
| | - Smaragda Cela
- Laboratory of Biology, Department of Basic Medical Sciences, Medical School, National and Kapodistrian University of Athens, 11527 Athens, Greece
- Medical Physics Unit, 2nd Department of Radiology, Medical School, National and Kapodistrian University of Athens, Attikon University Hospital, 12462 Athens, Greece
| | - Evangelia A. Pavlatou
- Laboratory of General Chemistry, School of Chemical Engineering, National Technical University of Athens, Zografou Campus, 15772 Athens, Greece
| | - Maria Gazouli
- Laboratory of Biology, Department of Basic Medical Sciences, Medical School, National and Kapodistrian University of Athens, 11527 Athens, Greece
- School of Science and Technology, Hellenic Open University, 26335 Patra, Greece
| | - Efstathios Efstathopoulos
- Biomedical Research Foundation, Academy of Athens, 11527 Athens, Greece
- School of Science and Technology, Hellenic Open University, 26335 Patra, Greece
| |
Collapse
|
2
|
Fahimirad B, Malekshah RE, Chamjangali MA, Abasabadi RK, Bromand S. Theoretical and experimental study of the photodegradation of methyl orange in the presence of different morphologies of Au-ZnO using Monte Carlo dynamic simulation. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2022; 29:55131-55146. [PMID: 35318599 DOI: 10.1007/s11356-022-19657-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Accepted: 03/07/2022] [Indexed: 06/14/2023]
Abstract
Herein, a simple approach was formed based on synthesizing different morphologies of ZnO and Au-ZnO as photocatalyst. In this study, ZnO and Au-ZnO were synthesized via a co-precipitation method and fully characterized via scanning electron microscopy (SEM), X-ray diffraction (XRD), and energy-dispersive X-ray spectroscopy (EDX). Three different ratios of Zn2+:OH- (1:2, 1:3, and 1:5) controlled the morphology of samples, which were made into spindle, star, and flower structures, respectively. Then, the photocatalytic activity was studied and compared. Their comparison showed that the flower morphology for ZnO and Au-ZnO was more effective in photocatalytic degradation and decolorization of methyl orange dye. Also, quantum and Monte Carlo (MC) calculations were carried out to investigate the adsorption of methyl orange (MO) molecules on ZnO(111) surface in the presence of Au or without Au in aqueous conditions by Monte Carlo adsorption locator simulations in the Materials Studio 2017 software. Au created a tendency to form a relatively strong interaction of MO with the ZnO(111) surface. The adsorption of MO on Au-ZnO(111) in the presence of Au was more significant than that of MO on ZnO(111), suggesting Au could significantly improve the reactivity of the methyl orange toward the ZnO(111).
Collapse
Affiliation(s)
- Bahareh Fahimirad
- Department of Rubber Processing and Engineering, Faculty of Processing, Iran Polymer and Petrochemical Institute (IPPI), P.O. Box: 14975/112, Tehran, Iran.
| | | | | | - Reza Khaleghi Abasabadi
- Catalysis and Nanostructured Materials Research Laboratory, School of Chemical Engineering, College of Engineering, University of Tehran, Tehran, Iran
| | - Samira Bromand
- Department of Chemistry, Shahrood University of Technology, Shahrood, Iran
| |
Collapse
|
3
|
Optical Sensing of Molecular Oxygen (O2) via Metal Oxide Photoluminescence: A Comparative Study of TiO2, SnO2 and ZnO. CHEMOSENSORS 2021. [DOI: 10.3390/chemosensors9070163] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
A comparative study is presented on the photoluminescence (PL) response toward molecular oxygen (O2) in tin dioxide (SnO2), zinc oxide (ZnO) and titanium dioxide (TiO2) nanoparticles. The findings show that both PL enhancement and PL quenching can be observed on different materials, arguably depending on the spatial localization of the defects responsible for the PL emission in each different oxide. No significant results are evidenced for SnO2 nanoparticles. ZnO with red/orange emission shown an O2-induced PL enhancement, suggesting that the radiative emission involves holes trapped in surface vacancy oxygen centers. While the ZnO results are scientifically interesting, its performances are inferior to the ones shown by TiO2, which exhibits the most interesting response in terms of sensitivity and versatility of the response. In particular, O2 concentrations in the range of few percent and in the range of a few tenths of a part per million are both detectable through the same mixed-phase TiO2 sample, whose rutile phase gives a reversible and fast response to larger (0.4–2%) O2 concentration while its anatase phase is usable for detection in the 25–75 ppm range. The data for rutile TiO2 suggest that its surfaces host deeply trapped electrons at large densities, allowing good sensitivities and, more notably, a relatively unsaturated response at large concentrations. Future work is expected to improve the understanding and modeling of the photophysical framework that lies behind the observations.
Collapse
|
4
|
Huízar-Padilla E, Guillén-Bonilla H, Guillén-Bonilla A, Rodríguez-Betancourtt VM, Sánchez-Martínez A, Guillen-Bonilla JT, Gildo-Ortiz L, Reyes-Gómez J. Synthesis of ZnAl 2O 4 and Evaluation of the Response in Propane Atmospheres of Pellets and Thick Films Manufactured with Powders of the Oxide. SENSORS (BASEL, SWITZERLAND) 2021; 21:2362. [PMID: 33805344 PMCID: PMC8037716 DOI: 10.3390/s21072362] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Revised: 03/20/2021] [Accepted: 03/26/2021] [Indexed: 11/22/2022]
Abstract
ZnAl2O4 nanoparticles were synthesized employing a colloidal method. The oxide powders were obtained at 300 °C, and their crystalline phase was corroborated by X-ray diffraction. The composition and chemical structure of the ZnAl2O4 was carried out by X-ray and photoelectron spectroscopy (XPS). The optical properties were studied by UV-vis spectroscopy, confirming that the ZnAl2O4 nanoparticles had a direct transition with bandgap energy of 3.2 eV. The oxide's microstructures were microbars of ~18.2 nm in size (on average), as analyzed by scanning (SEM) and transmission (TEM) electron microscopies. Dynamic and stationary gas detection tests were performed in controlled propane atmospheres, obtaining variations concerning the concentration of the test gas and the operating temperature. The optimum temperatures for detecting propane concentrations were 200 and 300 °C. In the static test results, the ZnAl2O4 showed increases in propane response since changes in the material's electrical conductance were recorded (conductance = 1/electrical resistance, Ω). The increases were ~2.8 at 200 °C and ~7.8 at 300 °C. The yield shown by the ZnAl2O4 nanoparticles for detecting propane concentrations was optimal compared to other similar oxides categorized as potential gas sensors.
Collapse
Affiliation(s)
| | - Héctor Guillén-Bonilla
- Departamento de Ingeniería de Proyectos, CUCEI, Universidad de Guadalajara, M. García Barragán 1421, Guadalajara 44410, Jalisco, Mexico
| | - Alex Guillén-Bonilla
- Departamento de Ciencias Computacionales e Ingenierías, CUVALLES, Universidad de Guadalajara, Carretera Guadalajara-Ameca Km 45.5, Ameca 46600, Jalisco, Mexico;
| | | | - A. Sánchez-Martínez
- CONACYT-Unidad Académica de Ciencias Químicas, Universidad Autónoma de Zacatecas, Campus Siglo XXI, Carretera Zacatecas—Guadalajara Km 6, Ejido la Escondida, Zacatecas 98160, Zacatecas, Mexico;
| | - José Trinidad Guillen-Bonilla
- Departamento de Electrónica, CUCEI, Universidad de Guadalajara, M. García Barragán 1421, Guadalajara 44410, Jalisco, Mexico;
| | - Lorenzo Gildo-Ortiz
- Departamento de Física, CUCEI, Universidad de Guadalajara, Guadalajara 44410, Jalisco, Mexico;
| | - Juan Reyes-Gómez
- Facultad de Ciencias, Universidad de Colima, Bernal Díaz del Castillo 340, Colima 28045, Colima, Mexico;
| |
Collapse
|