1
|
赵 思, 刘 明, 刘 名, 杨 晓, 熊 鹏, 张 杰. [Detection model of atrial fibrillation based on multi-branch and multi-scale convolutional networks]. SHENG WU YI XUE GONG CHENG XUE ZA ZHI = JOURNAL OF BIOMEDICAL ENGINEERING = SHENGWU YIXUE GONGCHENGXUE ZAZHI 2024; 41:700-707. [PMID: 39218595 PMCID: PMC11366475 DOI: 10.7507/1001-5515.202303014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 07/12/2024] [Indexed: 09/04/2024]
Abstract
Atrial fibrillation (AF) is a life-threatening heart condition, and its early detection and treatment have garnered significant attention from physicians in recent years. Traditional methods of detecting AF heavily rely on doctor's diagnosis based on electrocardiograms (ECGs), but prolonged analysis of ECG signals is very time-consuming. This paper designs an AF detection model based on the Inception module, constructing multi-branch detection channels to process raw ECG signals, gradient signals, and frequency signals during AF. The model efficiently extracted QRS complex and RR interval features using gradient signals, extracted P-wave and f-wave features using frequency signals, and used raw signals to supplement missing information. The multi-scale convolutional kernels in the Inception module provided various receptive fields and performed comprehensive analysis of the multi-branch results, enabling early AF detection. Compared to current machine learning algorithms that use only RR interval and heart rate variability features, the proposed algorithm additionally employed frequency features, making fuller use of the information within the signals. For deep learning methods using raw and frequency signals, this paper introduced an enhanced method for the QRS complex, allowing the network to extract features more effectively. By using a multi-branch input mode, the model comprehensively considered irregular RR intervals and P-wave and f-wave features in AF. Testing on the MIT-BIH AF database showed that the inter-patient detection accuracy was 96.89%, sensitivity was 97.72%, and specificity was 95.88%. The proposed model demonstrates excellent performance and can achieve automatic AF detection.
Collapse
Affiliation(s)
- 思宇 赵
- 河北大学 电子信息工程学院(河北保定 071002)College of Electronic and Information Engineering, Hebei University, Baoding, Hebei 071002, P. R. China
| | - 明 刘
- 河北大学 电子信息工程学院(河北保定 071002)College of Electronic and Information Engineering, Hebei University, Baoding, Hebei 071002, P. R. China
| | - 名起 刘
- 河北大学 电子信息工程学院(河北保定 071002)College of Electronic and Information Engineering, Hebei University, Baoding, Hebei 071002, P. R. China
| | - 晓茹 杨
- 河北大学 电子信息工程学院(河北保定 071002)College of Electronic and Information Engineering, Hebei University, Baoding, Hebei 071002, P. R. China
| | - 鹏 熊
- 河北大学 电子信息工程学院(河北保定 071002)College of Electronic and Information Engineering, Hebei University, Baoding, Hebei 071002, P. R. China
| | - 杰烁 张
- 河北大学 电子信息工程学院(河北保定 071002)College of Electronic and Information Engineering, Hebei University, Baoding, Hebei 071002, P. R. China
| |
Collapse
|
2
|
Ding C, Xiao R, Wang W, Holdsworth E, Hu X. Photoplethysmography based atrial fibrillation detection: a continually growing field. Physiol Meas 2024; 45:04TR01. [PMID: 38530307 DOI: 10.1088/1361-6579/ad37ee] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2023] [Accepted: 03/26/2024] [Indexed: 03/27/2024]
Abstract
Objective. Atrial fibrillation (AF) is a prevalent cardiac arrhythmia associated with significant health ramifications, including an elevated susceptibility to ischemic stroke, heart disease, and heightened mortality. Photoplethysmography (PPG) has emerged as a promising technology for continuous AF monitoring for its cost-effectiveness and widespread integration into wearable devices. Our team previously conducted an exhaustive review on PPG-based AF detection before June 2019. However, since then, more advanced technologies have emerged in this field.Approach. This paper offers a comprehensive review of the latest advancements in PPG-based AF detection, utilizing digital health and artificial intelligence (AI) solutions, within the timeframe spanning from July 2019 to December 2022. Through extensive exploration of scientific databases, we have identified 57 pertinent studies.Significance. Our comprehensive review encompasses an in-depth assessment of the statistical methodologies, traditional machine learning techniques, and deep learning approaches employed in these studies. In addition, we address the challenges encountered in the domain of PPG-based AF detection. Furthermore, we maintain a dedicated website to curate the latest research in this area, with regular updates on a regular basis.
Collapse
Affiliation(s)
- Cheng Ding
- Nell Hodgson Woodruff School of Nursing, Emory University, Atlanta, GA, United States of America
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, United States of America
| | - Ran Xiao
- Nell Hodgson Woodruff School of Nursing, Emory University, Atlanta, GA, United States of America
| | - Weijia Wang
- Nell Hodgson Woodruff School of Nursing, Emory University, Atlanta, GA, United States of America
| | - Elizabeth Holdsworth
- Georgia Tech Library, Georgia Institute of Technology, Atlanta, GA, United States of America
| | - Xiao Hu
- Nell Hodgson Woodruff School of Nursing, Emory University, Atlanta, GA, United States of America
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, United States of America
- Department of Biomedical Informatics, Emory University School of Medicine, Atlanta, GA, United States of America
| |
Collapse
|
3
|
Moreno-Sánchez PA, García-Isla G, Corino VDA, Vehkaoja A, Brukamp K, van Gils M, Mainardi L. ECG-based data-driven solutions for diagnosis and prognosis of cardiovascular diseases: A systematic review. Comput Biol Med 2024; 172:108235. [PMID: 38460311 DOI: 10.1016/j.compbiomed.2024.108235] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 02/07/2024] [Accepted: 02/25/2024] [Indexed: 03/11/2024]
Abstract
Cardiovascular diseases (CVD) are a leading cause of death globally, and result in significant morbidity and reduced quality of life. The electrocardiogram (ECG) plays a crucial role in CVD diagnosis, prognosis, and prevention; however, different challenges still remain, such as an increasing unmet demand for skilled cardiologists capable of accurately interpreting ECG. This leads to higher workload and potential diagnostic inaccuracies. Data-driven approaches, such as machine learning (ML) and deep learning (DL) have emerged to improve existing computer-assisted solutions and enhance physicians' ECG interpretation of the complex mechanisms underlying CVD. However, many ML and DL models used to detect ECG-based CVD suffer from a lack of explainability, bias, as well as ethical, legal, and societal implications (ELSI). Despite the critical importance of these Trustworthy Artificial Intelligence (AI) aspects, there is a lack of comprehensive literature reviews that examine the current trends in ECG-based solutions for CVD diagnosis or prognosis that use ML and DL models and address the Trustworthy AI requirements. This review aims to bridge this knowledge gap by providing a systematic review to undertake a holistic analysis across multiple dimensions of these data-driven models such as type of CVD addressed, dataset characteristics, data input modalities, ML and DL algorithms (with a focus on DL), and aspects of Trustworthy AI like explainability, bias and ethical considerations. Additionally, within the analyzed dimensions, various challenges are identified. To these, we provide concrete recommendations, equipping other researchers with valuable insights to understand the current state of the field comprehensively.
Collapse
Affiliation(s)
| | - Guadalupe García-Isla
- Department of Electronics Information and Bioengineering, Politecnico di Milano, Italy
| | - Valentina D A Corino
- Department of Electronics Information and Bioengineering, Politecnico di Milano, Italy
| | - Antti Vehkaoja
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| | | | - Mark van Gils
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| | - Luca Mainardi
- Department of Electronics Information and Bioengineering, Politecnico di Milano, Italy
| |
Collapse
|
4
|
Kim J, Lee SJ, Ko B, Lee M, Lee YS, Lee KH. Identification of Atrial Fibrillation With Single-Lead Mobile ECG During Normal Sinus Rhythm Using Deep Learning. J Korean Med Sci 2024; 39:e56. [PMID: 38317452 PMCID: PMC10843976 DOI: 10.3346/jkms.2024.39.e56] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Accepted: 12/04/2023] [Indexed: 02/07/2024] Open
Abstract
BACKGROUND The acquisition of single-lead electrocardiogram (ECG) from mobile devices offers a more practical approach to arrhythmia detection. Using artificial intelligence for atrial fibrillation (AF) identification enhances screening efficiency. However, the potential of single-lead ECG for AF identification during normal sinus rhythm (NSR) remains under-explored. This study introduces a method to identify AF using single-lead mobile ECG during NSR. METHODS We employed three deep learning models: recurrent neural network (RNN), long short-term memory (LSTM), and residual neural networks (ResNet50). From a dataset comprising 13,509 ECGs from 6,719 patients, 10,287 NSR ECGs from 5,170 patients were selected. Single-lead mobile ECGs underwent noise filtering and segmentation into 10-second intervals. A random under-sampling was applied to reduce bias from data imbalance. The final analysis involved 31,767 ECG segments, including 15,157 labeled as masked AF and 16,610 as Healthy. RESULTS ResNet50 outperformed the other models, achieving a recall of 79.3%, precision of 65.8%, F1-score of 71.9%, accuracy of 70.5%, and an area under the receiver operating characteristic curve (AUC) of 0.79 in identifying AF from NSR ECGs. Comparative performance scores for RNN and LSTM were 0.75 and 0.74, respectively. In an external validation set, ResNet50 attained an F1-score of 64.1%, recall of 68.9%, precision of 60.0%, accuracy of 63.4%, and AUC of 0.68. CONCLUSION The deep learning model using single-lead mobile ECG during NSR effectively identified AF at risk in future. However, further research is needed to enhance the performance of deep learning models for clinical application.
Collapse
Affiliation(s)
- Jiwoong Kim
- Department of Mathematics and Statistics, Chonnam National University, Gwangju, Korea
- Department of Cardiovascular Medicine, Chonnam National University Hospital, Gwangju, Korea
| | | | - Bonggyun Ko
- Department of Mathematics and Statistics, Chonnam National University, Gwangju, Korea
- XRAI, Gwangju, Korea
| | - Myungeun Lee
- Department of Cardiovascular Medicine, Chonnam National University Hospital, Gwangju, Korea
- Department of Internal Medicine, Chonnam National University Medical School, Gwangju, Korea
| | | | - Ki Hong Lee
- Department of Cardiovascular Medicine, Chonnam National University Hospital, Gwangju, Korea
- Department of Internal Medicine, Chonnam National University Medical School, Gwangju, Korea.
| |
Collapse
|
5
|
Lao M, Ou Q, Shan G, Zheng M, Pei G, Xu Y, Wang L, Tan J, Lu B. Pulse rate variability predicted cardiovascular disease in sleep disordered breathing: The Guangdong sleep health study. Respir Med 2023; 219:107408. [PMID: 37734671 DOI: 10.1016/j.rmed.2023.107408] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 08/29/2023] [Accepted: 09/08/2023] [Indexed: 09/23/2023]
Abstract
OBJECTIVES Pulse rate variability (PRV) predicts stroke in patients with sleep disordered breathing (SDB). However, the relationship between PRV and cardiovascular disease (CVD) was unknown in SDB. METHODS This was a cross-sectional study. Community residents in Guangdong were investigated. Sleep study were conducted with a type Ⅳ sleep monitoring. PRV parameters was assessed from the pulse waveforms derived from the sleep monitoring. RESULTS 3747 participants were enrolled. The mean age was 53.9 ± 12.7 years. 1149 (30.7%) were diagnosed as SDB. PRV parameters, except for the averages of pulse-to-pulse intervals (ANN), were higher in participants with SDB than those without. After adjusting for traditional CVD risk factors, deceleration capacity of rate (DC), ANN, and the percentage of pulse-to-pulse interval differences that were more than 50 ms (PNN50) were correlated with CVD risk in participants with SDB (OR were 0.826, 1.002, and 1.285; P were 0.003, 0.009, and 0.010), but not in participants without SDB. There was no interaction effect between DC, ANN, PNN50 and oxygen desaturation index. In hierarchical analysis, DC and ANN were predictors for CVD in SDB patients with age <60 years, male, overweight, diabetes, and normal lipid metabolism. PNN50 was predictor for CVD in the elderly SDB patients without overweight, diabetes or dyslipidemia. CONCLUSIONS PRV parameters may be specific predictors for CVD in SDB. PNN50 was a potent biomarker for CVD risk in the elderly with SDB, event without traditional CVD risk factors.
Collapse
Affiliation(s)
- Miaochan Lao
- Sleep Center, Department of Pulmonary and Critical Care Medicine, Guangdong Provincial Geriatrics Institute, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
| | - Qiong Ou
- Sleep Center, Department of Pulmonary and Critical Care Medicine, Guangdong Provincial Geriatrics Institute, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China.
| | - Guangliang Shan
- Department of Epidemiology and Statistics, Institute of Basic Medical Sciences, School of Basic Medicine, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing 100730, China
| | - Murui Zheng
- Guangzhou Center for Disease Control and Prevention, Guangzhou 510440, China
| | - Guo Pei
- Sleep Center, Department of Pulmonary and Critical Care Medicine, Guangdong Provincial Geriatrics Institute, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
| | - Yanxia Xu
- Sleep Center, Department of Pulmonary and Critical Care Medicine, Guangdong Provincial Geriatrics Institute, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
| | - Longlong Wang
- Sleep Center, Department of Pulmonary and Critical Care Medicine, Guangdong Provincial Geriatrics Institute, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
| | - Jiaoying Tan
- Sleep Center, Department of Pulmonary and Critical Care Medicine, Guangdong Provincial Geriatrics Institute, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
| | - Bin Lu
- Sleep Center, Department of Pulmonary and Critical Care Medicine, Guangdong Provincial Geriatrics Institute, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
| |
Collapse
|
6
|
Li J, Jia H, Zhou J, Huang X, Xu L, Jia S, Gao Z, Yao K, Li D, Zhang B, Liu Y, Huang Y, Hu Y, Zhao G, Xu Z, Li J, Yiu CK, Gao Y, Wu M, Jiao Y, Zhang Q, Tai X, Chan RH, Zhang Y, Ma X, Yu X. Thin, soft, wearable system for continuous wireless monitoring of artery blood pressure. Nat Commun 2023; 14:5009. [PMID: 37591881 PMCID: PMC10435523 DOI: 10.1038/s41467-023-40763-3] [Citation(s) in RCA: 24] [Impact Index Per Article: 24.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2023] [Accepted: 08/07/2023] [Indexed: 08/19/2023] Open
Abstract
Continuous monitoring of arterial blood pressure (BP) outside of a clinical setting is crucial for preventing and diagnosing hypertension related diseases. However, current continuous BP monitoring instruments suffer from either bulky systems or poor user-device interfacial performance, hampering their applications in continuous BP monitoring. Here, we report a thin, soft, miniaturized system (TSMS) that combines a conformal piezoelectric sensor array, an active pressure adaptation unit, a signal processing module, and an advanced machine learning method, to allow real wearable, continuous wireless monitoring of ambulatory artery BP. By optimizing the materials selection, control/sampling strategy, and system integration, the TSMS exhibits improved interfacial performance while maintaining Grade A level measurement accuracy. Initial trials on 87 volunteers and clinical tracking of two hypertension individuals prove the capability of the TSMS as a reliable BP measurement product, and its feasibility and practical usability in precise BP control and personalized diagnosis schemes development.
Collapse
Affiliation(s)
- Jian Li
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Huiling Jia
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Jingkun Zhou
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Xingcan Huang
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Long Xu
- School of Mechanical and Aerospace Engineering, Jilin University, 130012, Changchun, China
| | - Shengxin Jia
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Zhan Gao
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Kuanming Yao
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Dengfeng Li
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Binbin Zhang
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Yiming Liu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Ya Huang
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Yue Hu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Guangyao Zhao
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Zitong Xu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Jiyu Li
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Chun Ki Yiu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Yuyu Gao
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Mengge Wu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China (UESTC), 610054, Chengdu, China
| | - Yanli Jiao
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Qiang Zhang
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Xuecheng Tai
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
- Department of Mathematics, Hong Kong Baptist University, Hong Kong, China
| | - Raymond H Chan
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Yuanting Zhang
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Xiaohui Ma
- Department of vascular and endovascular surgery, The first medical center of Chinese PLA General Hospital, 100853, Beijing, China.
| | - Xinge Yu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China.
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China.
- City University of Hong Kong Shenzhen Research Institute, 518057, Shenzhen, China.
| |
Collapse
|
7
|
Aldughayfiq B, Ashfaq F, Jhanjhi NZ, Humayun M. A Deep Learning Approach for Atrial Fibrillation Classification Using Multi-Feature Time Series Data from ECG and PPG. Diagnostics (Basel) 2023; 13:2442. [PMID: 37510187 PMCID: PMC10377944 DOI: 10.3390/diagnostics13142442] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 07/08/2023] [Accepted: 07/13/2023] [Indexed: 07/30/2023] Open
Abstract
Atrial fibrillation is a prevalent cardiac arrhythmia that poses significant health risks to patients. The use of non-invasive methods for AF detection, such as Electrocardiogram and Photoplethysmogram, has gained attention due to their accessibility and ease of use. However, there are challenges associated with ECG-based AF detection, and the significance of PPG signals in this context has been increasingly recognized. The limitations of ECG and the untapped potential of PPG are taken into account as this work attempts to classify AF and non-AF using PPG time series data and deep learning. In this work, we emploted a hybrid deep neural network comprising of 1D CNN and BiLSTM for the task of AF classification. We addressed the under-researched area of applying deep learning methods to transmissive PPG signals by proposing a novel approach. Our approach involved integrating ECG and PPG signals as multi-featured time series data and training deep learning models for AF classification. Our hybrid 1D CNN and BiLSTM model achieved an accuracy of 95% on test data in identifying atrial fibrillation, showcasing its strong performance and reliable predictive capabilities. Furthermore, we evaluated the performance of our model using additional metrics. The precision of our classification model was measured at 0.88, indicating its ability to accurately identify true positive cases of AF. The recall, or sensitivity, was measured at 0.85, illustrating the model's capacity to detect a high proportion of actual AF cases. Additionally, the F1 score, which combines both precision and recall, was calculated at 0.84, highlighting the overall effectiveness of our model in classifying AF and non-AF cases.
Collapse
Affiliation(s)
- Bader Aldughayfiq
- Department of Information Systems, College of Computer and Information Sciences, Jouf University, Sakaka 72388, Saudi Arabia
| | - Farzeen Ashfaq
- School of Computer Science, SCS, Taylor's University, Subang Jaya 47500, Malaysia
| | - N Z Jhanjhi
- School of Computer Science, SCS, Taylor's University, Subang Jaya 47500, Malaysia
| | - Mamoona Humayun
- Department of Information Systems, College of Computer and Information Sciences, Jouf University, Sakaka 72388, Saudi Arabia
| |
Collapse
|
8
|
Neri L, Oberdier MT, van Abeelen KCJ, Menghini L, Tumarkin E, Tripathi H, Jaipalli S, Orro A, Paolocci N, Gallelli I, Dall’Olio M, Beker A, Carrick RT, Borghi C, Halperin HR. Electrocardiogram Monitoring Wearable Devices and Artificial-Intelligence-Enabled Diagnostic Capabilities: A Review. SENSORS (BASEL, SWITZERLAND) 2023; 23:4805. [PMID: 37430719 PMCID: PMC10223364 DOI: 10.3390/s23104805] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Revised: 05/09/2023] [Accepted: 05/12/2023] [Indexed: 07/12/2023]
Abstract
Worldwide, population aging and unhealthy lifestyles have increased the incidence of high-risk health conditions such as cardiovascular diseases, sleep apnea, and other conditions. Recently, to facilitate early identification and diagnosis, efforts have been made in the research and development of new wearable devices to make them smaller, more comfortable, more accurate, and increasingly compatible with artificial intelligence technologies. These efforts can pave the way to the longer and continuous health monitoring of different biosignals, including the real-time detection of diseases, thus providing more timely and accurate predictions of health events that can drastically improve the healthcare management of patients. Most recent reviews focus on a specific category of disease, the use of artificial intelligence in 12-lead electrocardiograms, or on wearable technology. However, we present recent advances in the use of electrocardiogram signals acquired with wearable devices or from publicly available databases and the analysis of such signals with artificial intelligence methods to detect and predict diseases. As expected, most of the available research focuses on heart diseases, sleep apnea, and other emerging areas, such as mental stress. From a methodological point of view, although traditional statistical methods and machine learning are still widely used, we observe an increasing use of more advanced deep learning methods, specifically architectures that can handle the complexity of biosignal data. These deep learning methods typically include convolutional and recurrent neural networks. Moreover, when proposing new artificial intelligence methods, we observe that the prevalent choice is to use publicly available databases rather than collecting new data.
Collapse
Affiliation(s)
- Luca Neri
- Department of Medicine, Division of Cardiology, Johns Hopkins University, Baltimore, MD 21218, USA; (L.N.)
- Department of Medical and Surgical Sciences, University of Bologna, 40138 Bologna, Italy
| | - Matt T. Oberdier
- Department of Medicine, Division of Cardiology, Johns Hopkins University, Baltimore, MD 21218, USA; (L.N.)
| | - Kirsten C. J. van Abeelen
- Department of Informatics, Systems, and Communication, University of Milano-Bicocca, 20126 Milan, Italy
- Department of Internal Medicine, Radboud University Medical Center, 6525 AJ Nijmegen, The Netherlands
| | - Luca Menghini
- Department of Psychology and Cognitive Science, University of Trento, 38068 Rovereto, Italy
| | - Ethan Tumarkin
- Department of Medicine, Division of Cardiology, Johns Hopkins University, Baltimore, MD 21218, USA; (L.N.)
| | - Hemantkumar Tripathi
- Department of Medicine, Division of Cardiology, Johns Hopkins University, Baltimore, MD 21218, USA; (L.N.)
| | - Sujai Jaipalli
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA
| | - Alessandro Orro
- Institute of Biomedical Technologies, National Research Council, 20054 Segrate, Italy
| | - Nazareno Paolocci
- Department of Medicine, Division of Cardiology, Johns Hopkins University, Baltimore, MD 21218, USA; (L.N.)
| | - Ilaria Gallelli
- Department of Medical and Surgical Sciences, University of Bologna, 40138 Bologna, Italy
| | - Massimo Dall’Olio
- Department of Medical and Surgical Sciences, University of Bologna, 40138 Bologna, Italy
| | - Amir Beker
- AccYouRate Group S.p.A., 67100 L’Aquila, Italy
| | - Richard T. Carrick
- Department of Medicine, Division of Cardiology, Johns Hopkins University, Baltimore, MD 21218, USA; (L.N.)
| | - Claudio Borghi
- Department of Medical and Surgical Sciences, University of Bologna, 40138 Bologna, Italy
| | - Henry R. Halperin
- Department of Medicine, Division of Cardiology, Johns Hopkins University, Baltimore, MD 21218, USA; (L.N.)
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA
- Department of Radiology, Johns Hopkins University, Baltimore, MD 21205, USA
| |
Collapse
|
9
|
Bernal Oñate CP, Melgarejo Meseguer FM, Carrera EV, Sánchez Muñoz JJ, García Alberola A, Rojo Álvarez JL. Different Ventricular Fibrillation Types in Low-Dimensional Latent Spaces. SENSORS (BASEL, SWITZERLAND) 2023; 23:2527. [PMID: 36904731 PMCID: PMC10006875 DOI: 10.3390/s23052527] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/24/2022] [Revised: 02/08/2023] [Accepted: 02/13/2023] [Indexed: 06/18/2023]
Abstract
The causes of ventricular fibrillation (VF) are not yet elucidated, and it has been proposed that different mechanisms might exist. Moreover, conventional analysis methods do not seem to provide time or frequency domain features that allow for recognition of different VF patterns in electrode-recorded biopotentials. The present work aims to determine whether low-dimensional latent spaces could exhibit discriminative features for different mechanisms or conditions during VF episodes. For this purpose, manifold learning using autoencoder neural networks was analyzed based on surface ECG recordings. The recordings covered the onset of the VF episode as well as the next 6 min, and comprised an experimental database based on an animal model with five situations, including control, drug intervention (amiodarone, diltiazem, and flecainide), and autonomic nervous system blockade. The results show that latent spaces from unsupervised and supervised learning schemes yielded moderate though quite noticeable separability among the different types of VF according to their type or intervention. In particular, unsupervised schemes reached a multi-class classification accuracy of 66%, while supervised schemes improved the separability of the generated latent spaces, providing a classification accuracy of up to 74%. Thus, we conclude that manifold learning schemes can provide a valuable tool for studying different types of VF while working in low-dimensional latent spaces, as the machine-learning generated features exhibit separability among different VF types. This study confirms that latent variables are better VF descriptors than conventional time or domain features, making this technique useful in current VF research on elucidation of the underlying VF mechanisms.
Collapse
Affiliation(s)
- Carlos Paúl Bernal Oñate
- Departamento de Eléctrica, Electrónica y Telecomunicaciones, Universidad de las Fuerzas Armadas—ESPE, Sangolqui 171103, Ecuador
| | | | - Enrique V. Carrera
- Departamento de Eléctrica, Electrónica y Telecomunicaciones, Universidad de las Fuerzas Armadas—ESPE, Sangolqui 171103, Ecuador
| | | | | | - José Luis Rojo Álvarez
- Department of Signal Theory and Communications, Telematics and Computing Systems, Universidad Rey Juan Carlos, 28943 Madrid, Spain
| |
Collapse
|
10
|
Tian F, Yang J, Zhao S, Sawan M. NeuroCARE: A generic neuromorphic edge computing framework for healthcare applications. Front Neurosci 2023; 17:1093865. [PMID: 36755733 PMCID: PMC9900119 DOI: 10.3389/fnins.2023.1093865] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Accepted: 01/03/2023] [Indexed: 01/24/2023] Open
Abstract
Highly accurate classification methods for multi-task biomedical signal processing are reported, including neural networks. However, reported works are computationally expensive and power-hungry. Such bottlenecks make it hard to deploy existing approaches on edge platforms such as mobile and wearable devices. Gaining motivation from the good performance and high energy-efficiency of spiking neural networks (SNNs), a generic neuromorphic framework for edge healthcare and biomedical applications are proposed and evaluated on various tasks, including electroencephalography (EEG) based epileptic seizure prediction, electrocardiography (ECG) based arrhythmia detection, and electromyography (EMG) based hand gesture recognition. This approach, NeuroCARE, uses a unique sparse spike encoder to generate spike sequences from raw biomedical signals and makes classifications using the spike-based computing engine that combines the advantages of both CNN and SNN. An adaptive weight mapping method specifically co-designed with the spike encoder can efficiently convert CNN to SNN without performance deterioration. The evaluation results show that the overall performance, including the classification accuracy, sensitivity and F1 score, achieve 92.7, 96.7, and 85.7% for seizure prediction, arrhythmia detection and hand gesture recognition, respectively. In comparison with CNN topologies, the computation complexity is reduced by over 80.7% while the energy consumption and area occupation are reduced by over 80% and over 64.8%, respectively, indicating that the proposed neuromorphic computing approach is energy and area efficient and of high precision, which paves the way for deployment at edge platforms.
Collapse
Affiliation(s)
- Fengshi Tian
- CenBRAIN Neurotech, School of Engineering, Westlake University, Hangzhou, Zhejiang, China,The Hong Kong University of Science and Technology (HKUST), New Territories, Hong Kong SAR, China
| | - Jie Yang
- CenBRAIN Neurotech, School of Engineering, Westlake University, Hangzhou, Zhejiang, China,*Correspondence: Jie Yang,
| | - Shiqi Zhao
- CenBRAIN Neurotech, School of Engineering, Westlake University, Hangzhou, Zhejiang, China
| | - Mohamad Sawan
- CenBRAIN Neurotech, School of Engineering, Westlake University, Hangzhou, Zhejiang, China,Mohamad Sawan,
| |
Collapse
|
11
|
Kudo S, Chen Z, Zhou X, Izu LT, Chen-Izu Y, Zhu X, Tamura T, Kanaya S, Huang M. A training pipeline of an arrhythmia classifier for atrial fibrillation detection using Photoplethysmography signal. Front Physiol 2023; 14:1084837. [PMID: 36744032 PMCID: PMC9892629 DOI: 10.3389/fphys.2023.1084837] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Accepted: 01/02/2023] [Indexed: 01/20/2023] Open
Abstract
Photoplethysmography (PPG) signal is potentially suitable in atrial fibrillation (AF) detection for its convenience in use and similarity in physiological origin to electrocardiogram (ECG). There are a few preceding studies that have shown the possibility of using the peak-to-peak interval of the PPG signal (PPIp) in AF detection. However, as a generalized model, the accuracy of an AF detector should be pursued on the one hand; on the other hand, its generalizability should be paid attention to in view of the individual differences in PPG manifestation of even the same arrhythmia and the existence of sub-types. Moreover, a binary classifier for atrial fibrillation and normal sinus rhythm is not convincing enough for the similarity between AF and ectopic beats. In this study, we project the atrial fibrillation detection as a multiple-class classification and try to propose a training pipeline that is advantageous both to the accuracy and generalizability of the classifier by designing and determining the configurable options of the pipeline, in terms of input format, deep learning model (with hyperparameter optimization), and scheme of transfer learning. With a rigorous comparison of the possible combinations of the configurable components in the pipeline, we confirmed that first-order difference of heartbeat sequence as the input format, a 2-layer CNN-1-layer Transformer hybridR model as the learning model and the whole model fine-tuning as the implementing scheme of transfer learning is the best combination for the pipeline (F1 value: 0.80, overall accuracy: 0.87)R.
Collapse
Affiliation(s)
- Sota Kudo
- Computational Systems Biology Lab, Graduate School of Science and Technology, Nara Institute of Science and Technology, Ikoma, Japan
| | | | - Xue Zhou
- Computational Systems Biology Lab, Graduate School of Science and Technology, Nara Institute of Science and Technology, Ikoma, Japan
| | - Leighton T. Izu
- Department of Pharmacology, University of California, Davis, Davis, CA, United States
| | - Ye Chen-Izu
- Department of Biomedical Engineering, University of California, Davis, Davis, CA, United States
| | - Xin Zhu
- Biomedical Information Engineering Lab, The University of Aizu, Aizu-Wakamatsu, Japan
| | - Toshiyo Tamura
- Future Robotics Organization, Waseda University, Tokyo, Japan
| | - Shigehiko Kanaya
- Computational Systems Biology Lab, Graduate School of Science and Technology, Nara Institute of Science and Technology, Ikoma, Japan
| | - Ming Huang
- Computational Systems Biology Lab, Graduate School of Science and Technology, Nara Institute of Science and Technology, Ikoma, Japan,*Correspondence: Ming Huang ,
| |
Collapse
|
12
|
El-Baz A, Giridharan GA, Shalaby A, Mahmoud AH, Ghazal M. Special Issue "Computer Aided Diagnosis Sensors". SENSORS (BASEL, SWITZERLAND) 2022; 22:8052. [PMID: 36298403 PMCID: PMC9610085 DOI: 10.3390/s22208052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Accepted: 10/19/2022] [Indexed: 06/16/2023]
Abstract
Sensors used to diagnose, monitor or treat diseases in the medical domain are known as medical sensors [...].
Collapse
Affiliation(s)
- Ayman El-Baz
- Bioengineering Department, University of Louisville, Louisville, KY 40292, USA
| | | | - Ahmed Shalaby
- Bioengineering Department, University of Louisville, Louisville, KY 40292, USA
| | - Ali H. Mahmoud
- Bioengineering Department, University of Louisville, Louisville, KY 40292, USA
| | - Mohammed Ghazal
- Electrical, Computer, and Biomedical Engineering Department, Abu Dhabi University, Abu Dhabi 59911, United Arab Emirates
| |
Collapse
|
13
|
Chung CT, Lee S, King E, Liu T, Armoundas AA, Bazoukis G, Tse G. Clinical significance, challenges and limitations in using artificial intelligence for electrocardiography-based diagnosis. INTERNATIONAL JOURNAL OF ARRHYTHMIA 2022; 23:24. [PMID: 36212507 PMCID: PMC9525157 DOI: 10.1186/s42444-022-00075-x] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2022] [Accepted: 07/13/2022] [Indexed: 11/07/2022] Open
Abstract
Cardiovascular diseases are one of the leading global causes of mortality. Currently, clinicians rely on their own analyses or automated analyses of the electrocardiogram (ECG) to obtain a diagnosis. However, both approaches can only include a finite number of predictors and are unable to execute complex analyses. Artificial intelligence (AI) has enabled the introduction of machine and deep learning algorithms to compensate for the existing limitations of current ECG analysis methods, with promising results. However, it should be prudent to recognize that these algorithms also associated with their own unique set of challenges and limitations, such as professional liability, systematic bias, surveillance, cybersecurity, as well as technical and logistical challenges. This review aims to increase familiarity with and awareness of AI algorithms used in ECG diagnosis, and to ultimately inform the interested stakeholders on their potential utility in addressing present clinical challenges.
Collapse
Affiliation(s)
- Cheuk To Chung
- Cardiac Electrophysiology Unit, Cardiovascular Analytics Group, Hong Kong, China
| | - Sharen Lee
- Cardiac Electrophysiology Unit, Cardiovascular Analytics Group, Hong Kong, China
| | - Emma King
- Cardiac Electrophysiology Unit, Cardiovascular Analytics Group, Hong Kong, China
| | - Tong Liu
- Tianjin Key Laboratory of Ionic-Molecular Function of Cardiovascular Disease, Department of Cardiology, Tianjin Institute of Cardiology, Second Hospital of Tianjin Medical University, Tianjin, 300211 China
| | - Antonis A. Armoundas
- Cardiovascular Research Center, Massachusetts General Hospital, Boston, MA USA
- Broad Institute, Massachusetts Institute of Technology, Cambridge, MA USA
| | - George Bazoukis
- Department of Cardiology, Larnaca General Hospital, Inomenon Polition Amerikis, Larnaca, Cyprus
- Department of Basic and Clinical Sciences, University of Nicosia Medical School, 2414 Nicosia, Cyprus
| | - Gary Tse
- Tianjin Key Laboratory of Ionic-Molecular Function of Cardiovascular Disease, Department of Cardiology, Tianjin Institute of Cardiology, Second Hospital of Tianjin Medical University, Tianjin, 300211 China
- Kent and Medway Medical School, Canterbury, UK
| |
Collapse
|
14
|
Statistical and Diagnostic Properties of pRRx Parameters in Atrial Fibrillation Detection. J Clin Med 2022; 11:jcm11195702. [PMID: 36233572 PMCID: PMC9572524 DOI: 10.3390/jcm11195702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Revised: 09/22/2022] [Accepted: 09/23/2022] [Indexed: 11/30/2022] Open
Abstract
Background: We studied the diagnostic properties of the percentage of successive RR intervals differing by at least x ms (pRRx) as functions of the threshold value x in a range of 7 to 195 ms for the differentiation of atrial fibrillation (AF) from sinus rhythm (SR). Methods: RR intervals were measured in 60-s electrocardiogram (ECG) segments with either AF (32,141 segments) or SR (32,769 segments) from the publicly available Physionet Long-Term Atrial Fibrillation Database (LTAFDB). For validation, we have used ECGs from the Massachusetts Institute of Technology–Beth Israel Hospital (MIT–BIH) Atrial Fibrillation Database. The pRRx distributions in AF and SR in relation to x were studied by histograms, along with the mutual association by the nonparametric Spearman correlations for all pairs of pRRx, and separately for AF or SR. The optimal cutoff values for all pRRx were determined using the receiver operator curve characteristic. A nonparametric bootstrap with 5000 samples was used to calculate a 95% confidence interval for several classification metrics. Results: The distributions of pRRx for x in the 7–195 ms range are significantly different in AF than in SR. The sensitivity, specificity, accuracy, and diagnostic odds ratios differ for pRRx, with the highest values for x = 31 ms (pRR31) rather than x = 50 (pRR50), which is most commonly applied in studies on heart rate variability. For the optimal cutoff of pRR31 (68.79%), the sensitivity is 90.42%, specificity 95.37%, and the diagnostic odds ratio is 194.11. Validation with the ECGs from the MIT–BIH Atrial Fibrillation Database confirmed our findings. Conclusions: We demonstrate that the diagnostic properties of pRRx depend on x, and pRR31 outperforms pRR50, at least for ECGs of 60-s duration.
Collapse
|
15
|
Wearables in Cardiovascular Disease. J Cardiovasc Transl Res 2022:10.1007/s12265-022-10314-0. [PMID: 36085432 DOI: 10.1007/s12265-022-10314-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2022] [Accepted: 08/29/2022] [Indexed: 10/14/2022]
Abstract
Wearable devices stand to revolutionize the way healthcare is delivered. From consumer devices that provide general health information and screen for medical conditions to medical-grade devices that allow collection of larger datasets that include multiple modalities, wearables have a myriad of potential uses, especially in cardiovascular disorders. In this review, we summarize the underlying technologies employed in these devices and discuss the regulatory and economic aspects of such devices as well as the future implications of their use.
Collapse
|
16
|
Automatic Atrial Fibrillation Arrhythmia Detection Using Univariate and Multivariate Data. ALGORITHMS 2022. [DOI: 10.3390/a15070231] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Abstract
Atrial fibrillation (AF) is still a major cause of disease morbidity and mortality, making its early diagnosis desirable and urging researchers to develop efficient methods devoted to automatic AF detection. Till now, the analysis of Holter-ECG recordings remains the gold-standard technique to screen AF. This is usually achieved by studying either RR interval time series analysis, P-wave detection or combinations of both morphological characteristics. After extraction and selection of meaningful features, each of the AF detection methods might be conducted through univariate and multivariate data analysis. Many of these automatic techniques have been proposed over the last years. This work presents an overview of research studies of AF detection based on RR interval time series. The aim of this paper is to provide the scientific community and newcomers to the field of AF screening with a resource that presents introductory concepts, clinical features, and a literature review that describes the techniques that are mostly followed when RR interval time series are used for accurate detection of AF.
Collapse
|
17
|
Ben Itzhak S, Ricon SS, Biton S, Behar JA, Sobel JA. Effect of temporal resolution on the detection of cardiac arrhythmias using HRV features and machine learning. Physiol Meas 2022; 43. [PMID: 35506573 DOI: 10.1088/1361-6579/ac6561] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2021] [Accepted: 04/07/2022] [Indexed: 11/11/2022]
Abstract
Objective.Arrhythmia is an abnormal cardiac rhythm that affects the pattern and rate of the heartbeat. Wearable devices with the functionality to measure and store heart rate (HR) data are growing in popularity and enable diagnosing and monitoring arrhythmia on a large scale. The typical sampling resolution of HR data available from non-medical grade wearable devices varies from seconds to several minutes depending on the device and its settings. However, the impact of sampling resolution on the performance and quality of arrhythmia detection has not yet been quantified.Approach.In this study, we investigated the detection and classification of three arrhythmias, namely atrial fibrillation, bradycardia, tachycardia, from down-sampled HR data with various temporal resolution (5-, 15-, 30- and 60 s averages) in 1 h segments extracted from an annotated Holter ECG database acquired at the University of Virginia Heart Station. For the classification task, a total of 15 common heart rate variability (HRV) features were engineered based on the HR time series of each patient. Three different types of machine learning classifiers were evaluated, namely logistic regression, support vector machine and random forest.Main results.A decrease in temporal resolution drastically impacted the detection of atrial fibrillation but did not substantially affect the detection of bradycardia and tachycardia. A HR resolution up to 15 s average demonstrated reasonable performance with a sensitivity of 0.92 and a specificity of 0.86 for a multiclass random forest classifier.Significance.HRV features extracted from low resolution long HR recordings have the potential to increase the early detection of arrhythmias in undiagnosed individuals.
Collapse
Affiliation(s)
| | | | - Shany Biton
- Biomedical Engineering Faculty, Technion-IIT, Haifa, Israel
| | | | | |
Collapse
|
18
|
Bonini N, Vitolo M, Imberti JF, Proietti M, Romiti GF, Boriani G, Paaske Johnsen S, Guo Y, Lip GYH. Mobile health technology in atrial fibrillation. Expert Rev Med Devices 2022; 19:327-340. [PMID: 35451347 DOI: 10.1080/17434440.2022.2070005] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
INTRODUCTION Mobile health (mHealth) solutions in atrial fibrillation (AF) are becoming widespread, thanks to everyday life devices such as smartphones. Their use is validated both in monitoring and in screening scenarios. In the published literature, the diagnostic accuracy of mHealth solutions wide differs, and their current clinical use is not well established in principal guidelines. AREAS COVERED mHealth solutions have progressively built an AF-detection chain to guide patients from the device's alert signal to the health care practitioners' (HCPs) attention. This review aims to critically evaluate the latest evidence regarding mHealth devices and the future possible patient's uses in everyday life. EXPERT OPINION The patients are the first to be informed of the rhythm anomaly, leading to the urgency of increasing the patients' AF self-management. Furthermore, HCPs need to update themselves about mHealth devices use in clinical practice. Nevertheless, these are promising instruments in specific populations, such as post-stroke patients, to promote an early arrhythmia diagnosis in the post-ablation/cardioversion period, allowing checks on the efficacy of the treatment or intervention.
Collapse
Affiliation(s)
- Niccolò Bonini
- Liverpool Centre for Cardiovascular Science, University of Liverpool and Liverpool Heart & Chest Hospital, Liverpool, United Kingdom.,Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Modena, Italy
| | - Marco Vitolo
- Liverpool Centre for Cardiovascular Science, University of Liverpool and Liverpool Heart & Chest Hospital, Liverpool, United Kingdom.,Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Modena, Italy.,Clinical and Experimental Medicine PhD Program, University of Modena and Reggio Emilia, Modena, Italy
| | - Jacopo Francesco Imberti
- Liverpool Centre for Cardiovascular Science, University of Liverpool and Liverpool Heart & Chest Hospital, Liverpool, United Kingdom.,Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Modena, Italy.,Clinical and Experimental Medicine PhD Program, University of Modena and Reggio Emilia, Modena, Italy
| | - Marco Proietti
- Liverpool Centre for Cardiovascular Science, University of Liverpool and Liverpool Heart & Chest Hospital, Liverpool, United Kingdom.,Department of Clinical Sciences and Community Health, University of Milan, Milan, Italy.,Geriatric Unit, IRCCS Istituti Clinici Scientifici Maugeri, Milan, Italy
| | - Giulio Francesco Romiti
- Liverpool Centre for Cardiovascular Science, University of Liverpool and Liverpool Heart & Chest Hospital, Liverpool, United Kingdom.,Department of Translational and Precision Medicine, Sapienza-University of Rome, Rome, Italy
| | - Giuseppe Boriani
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Modena, Italy
| | - Søren Paaske Johnsen
- Danish Center for Clinical Health Services Research (DACS), Department of Clinical Medicine, Aalborg University, Aalborg, Denmark
| | - Yutao Guo
- Department of Pulmonary Vessel and Thrombotic Disease, Sixth Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Gregory Y H Lip
- Liverpool Centre for Cardiovascular Science, University of Liverpool and Liverpool Heart & Chest Hospital, Liverpool, United Kingdom.,Danish Center for Clinical Health Services Research (DACS), Department of Clinical Medicine, Aalborg University, Aalborg, Denmark
| |
Collapse
|
19
|
Petmezas G, Stefanopoulos L, Kilintzis V, Tzavelis A, Rogers JA, Katsaggelos AK, Maglaveras N. State-of-the-art Deep Learning Methods on Electrocardiogram Data: A Systematic Review (Preprint). JMIR Med Inform 2022; 10:e38454. [PMID: 35969441 PMCID: PMC9425174 DOI: 10.2196/38454] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2022] [Revised: 06/03/2022] [Accepted: 07/03/2022] [Indexed: 11/13/2022] Open
Abstract
Background Electrocardiogram (ECG) is one of the most common noninvasive diagnostic tools that can provide useful information regarding a patient’s health status. Deep learning (DL) is an area of intense exploration that leads the way in most attempts to create powerful diagnostic models based on physiological signals. Objective This study aimed to provide a systematic review of DL methods applied to ECG data for various clinical applications. Methods The PubMed search engine was systematically searched by combining “deep learning” and keywords such as “ecg,” “ekg,” “electrocardiogram,” “electrocardiography,” and “electrocardiology.” Irrelevant articles were excluded from the study after screening titles and abstracts, and the remaining articles were further reviewed. The reasons for article exclusion were manuscripts written in any language other than English, absence of ECG data or DL methods involved in the study, and absence of a quantitative evaluation of the proposed approaches. Results We identified 230 relevant articles published between January 2020 and December 2021 and grouped them into 6 distinct medical applications, namely, blood pressure estimation, cardiovascular disease diagnosis, ECG analysis, biometric recognition, sleep analysis, and other clinical analyses. We provide a complete account of the state-of-the-art DL strategies per the field of application, as well as major ECG data sources. We also present open research problems, such as the lack of attempts to address the issue of blood pressure variability in training data sets, and point out potential gaps in the design and implementation of DL models. Conclusions We expect that this review will provide insights into state-of-the-art DL methods applied to ECG data and point to future directions for research on DL to create robust models that can assist medical experts in clinical decision-making.
Collapse
Affiliation(s)
- Georgios Petmezas
- Lab of Computing, Medical Informatics and Biomedical-Imaging Technologies, The Medical School, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Leandros Stefanopoulos
- Lab of Computing, Medical Informatics and Biomedical-Imaging Technologies, The Medical School, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Vassilis Kilintzis
- Lab of Computing, Medical Informatics and Biomedical-Imaging Technologies, The Medical School, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Andreas Tzavelis
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, United States
| | - John A Rogers
- Department of Material Science, Northwestern University, Evanston, IL, United States
| | - Aggelos K Katsaggelos
- Department of Electrical and Computer Engineering, Northwestern University, Evanston, IL, United States
| | - Nicos Maglaveras
- Lab of Computing, Medical Informatics and Biomedical-Imaging Technologies, The Medical School, Aristotle University of Thessaloniki, Thessaloniki, Greece
| |
Collapse
|
20
|
Machine learning in the detection and management of atrial fibrillation. Clin Res Cardiol 2022; 111:1010-1017. [PMID: 35353207 PMCID: PMC9424134 DOI: 10.1007/s00392-022-02012-3] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/11/2022] [Accepted: 03/16/2022] [Indexed: 12/04/2022]
Abstract
Machine learning has immense novel but also disruptive potential for medicine. Numerous applications have already been suggested and evaluated concerning cardiovascular diseases. One important aspect is the detection and management of potentially thrombogenic arrhythmias such as atrial fibrillation. While atrial fibrillation is the most common arrhythmia with a lifetime risk of one in three persons and an increased risk of thromboembolic complications such as stroke, many atrial fibrillation episodes are asymptomatic and a first diagnosis is oftentimes only reached after an embolic event. Therefore, screening for atrial fibrillation represents an important part of clinical practice. Novel technologies such as machine learning have the potential to substantially improve patient care and clinical outcomes. Additionally, machine learning applications may aid cardiologists in the management of patients with already diagnosed atrial fibrillation, for example, by identifying patients at a high risk of recurrence after catheter ablation. We summarize the current state of evidence concerning machine learning and, in particular, artificial neural networks in the detection and management of atrial fibrillation and describe possible future areas of development as well as pitfalls.
Collapse
|
21
|
Jiang J, Tian F, Liang J, Shen Z, Liu Y, Zheng J, Wu H, Zhang Z, Fang C, Zhao Y, Shi J, Xue X, Zeng X. MSPAN: A Memristive Spike-Based Computing Engine With Adaptive Neuron for Edge Arrhythmia Detection. Front Neurosci 2021; 15:761127. [PMID: 34975373 PMCID: PMC8715923 DOI: 10.3389/fnins.2021.761127] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Accepted: 11/22/2021] [Indexed: 11/13/2022] Open
Abstract
In this work, a memristive spike-based computing in memory (CIM) system with adaptive neuron (MSPAN) is proposed to realize energy-efficient remote arrhythmia detection with high accuracy in edge devices by software and hardware co-design. A multi-layer deep integrative spiking neural network (DiSNN) is first designed with an accuracy of 93.6% in 4-class ECG classification tasks. Then a memristor-based CIM architecture and the corresponding mapping method are proposed to deploy the DiSNN. By evaluation, the overall system achieves an accuracy of over 92.25% on the MIT-BIH dataset while the area is 3.438 mm2 and the power consumption is 0.178 μJ per heartbeat at a clock frequency of 500 MHz. These results reveal that the proposed MSPAN system is promising for arrhythmia detection in edge devices.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | | | | | | | - Xiaoyong Xue
- State Key Laboratory of ASIC and System, School of Microelectronics, Fudan University, Shanghai, China
| | | |
Collapse
|