1
|
Campos-Arias L, Peřinka N, Lau YC, Castro N, Pereira N, Correia VMG, Costa P, Vilas-Vilela JL, Lanceros-Mendez S. Improving Definition of Screen-Printed Functional Materials for Sensing Application. ACS APPLIED ELECTRONIC MATERIALS 2024; 6:2152-2160. [PMID: 38680726 PMCID: PMC11044814 DOI: 10.1021/acsaelm.3c01415] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Revised: 03/13/2024] [Accepted: 03/22/2024] [Indexed: 05/01/2024]
Abstract
Screen printing is one of the most used techniques for developing printed electronics. It stands out for its simplicity, scalability, and effectivity. Specifically, the manufacturing of hybrid integrated circuits has promoted the development of the technique, and the photovoltaic industry has enhanced the printing process by developing high-performance metallization pastes and high-end screens. In recent years, fine lines of 50 μm or smaller are about to be adopted in mass production, and screen printing has to compete with digital printing techniques such as inkjet printing, which can reach narrower lines. In this sense, this work is focused on testing the printing resolution of a high-performance stainless-steel screen with commercial conductive inks and functional lab-made inks based on reduced graphene oxide using an interdigitated structure. We achieved electrically conductive functional patterns with a minimum printing resolution of 40 μm for all inks.
Collapse
Affiliation(s)
- Lia Campos-Arias
- BCMaterials,
Basque Center for Materials, Applications and Nanostructures, UPV/EHU Science Park, 48940 Leioa, Spain
| | - Nikola Peřinka
- BCMaterials,
Basque Center for Materials, Applications and Nanostructures, UPV/EHU Science Park, 48940 Leioa, Spain
| | - Yin Cheung Lau
- Faculty
of Science and Engineering, Swansea University, SA1 8EN Swansea, U.K.
| | - Nelson Castro
- International
Iberian Nanotechnology Laboratory (INL), 4715-330 Braga, Portugal
- Physics
Centre of Minho and Porto, Universities (CF-UM-UP) and LaPMET - Laboratory
of Physics for Materials and Emergent Technologies, University of Minho, 4710-057 Braga, Portugal
| | - Nelson Pereira
- Physics
Centre of Minho and Porto, Universities (CF-UM-UP) and LaPMET - Laboratory
of Physics for Materials and Emergent Technologies, University of Minho, 4710-057 Braga, Portugal
| | - Vitor Manuel Gomes Correia
- Centre
for MicroElectroMechanics Systems (CMEMS), University of Minho, Campus de Azurém, 4800-058 Guimarães, Portugal
| | - Pedro Costa
- Physics
Centre of Minho and Porto, Universities (CF-UM-UP) and LaPMET - Laboratory
of Physics for Materials and Emergent Technologies, University of Minho, 4710-057 Braga, Portugal
| | - José Luis Vilas-Vilela
- BCMaterials,
Basque Center for Materials, Applications and Nanostructures, UPV/EHU Science Park, 48940 Leioa, Spain
- Grupo de
Química Macromolecular (LABQUIMAC) Dpto. Química-Física,
Facultad de Ciencia y Tecnología, Universidad del País Vasco (UPV/EHU), Leioa, Bizkaia 48940, Spain
| | - Senentxu Lanceros-Mendez
- BCMaterials,
Basque Center for Materials, Applications and Nanostructures, UPV/EHU Science Park, 48940 Leioa, Spain
- IKERBASQUE,
Basque Foundation for Science, 48009 Bilbao, Spain
| |
Collapse
|
2
|
Park JH, Lee GY, Song Z, Bong JH, Kim HR, Kang MJ, Pyun JC. A vertically paired electrode for redox cycling and its application to immunoassays. Analyst 2023; 148:1349-1361. [PMID: 36857647 DOI: 10.1039/d2an01648f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/23/2023]
Abstract
An electrochemical immunoassay based on the redox cycling method was presented using vertically paired electrodes (VPEs), which were fabricated using poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) as an electrode material and parylene-C as a dielectric layer. For the application to immunoassays, different electrochemical properties of PEDOT:PSS were analyzed for the redox reaction of 3,3',5,5'-tetramethylbenzidine (TMB, the chromogenic substrate for enzyme-immunoassays) at different pH conditions, including the conductivity (σ), electron transfer rate constant (kapp), and double-layer capacitance (Cdl). The influencing factors on the sensitivity of redox cycling based on VPE based on PEDOT:PSS were analyzed for the redox reaction of TMB, such as the electrode gap and number of electrode pairs. Computer simulation was also performed for the redox cycling results based on VPEs, which had limitations in fabrication, such as VPEs with an electrode gap of less than 100 nm and more than five electrode pairs. Finally, the redox cycling based on VPE was applied to the medical diagnosis of human hepatitis-C virus (hHCV) using a commercial ELISA kit. The sensitivity of the redox cycling method for the medical diagnosis of hHCV was compared with conventional assay methods, such as TMB-based chromogenic detection, luminol-based chemiluminescence assay, and a rapid test kit (lateral flow immunoassay).
Collapse
Affiliation(s)
- Jun-Hee Park
- Department of Materials Science and Engineering, Yonsei University, 50 Yonsei-Ro, Seodaemun-Gu, Seoul 03722, Korea.
| | - Ga-Yeon Lee
- Department of Materials Science and Engineering, Yonsei University, 50 Yonsei-Ro, Seodaemun-Gu, Seoul 03722, Korea. .,Electronic Convergence Division, Korea Institute of Ceramic Engineering and Technology (KICET), Jinju, Korea
| | - Zhiquan Song
- Department of Materials Science and Engineering, Yonsei University, 50 Yonsei-Ro, Seodaemun-Gu, Seoul 03722, Korea.
| | - Ji-Hong Bong
- Department of Materials Science and Engineering, Yonsei University, 50 Yonsei-Ro, Seodaemun-Gu, Seoul 03722, Korea.
| | - Hong-Rae Kim
- Department of Materials Science and Engineering, Yonsei University, 50 Yonsei-Ro, Seodaemun-Gu, Seoul 03722, Korea.
| | - Min-Jung Kang
- Korea Institute of Science and Technology (KIST), Seoul, Korea
| | - Jae-Chul Pyun
- Department of Materials Science and Engineering, Yonsei University, 50 Yonsei-Ro, Seodaemun-Gu, Seoul 03722, Korea.
| |
Collapse
|
3
|
Capacitive biosensor based on vertically paired electrodes for the detection of SARS-CoV-2. Biosens Bioelectron 2022; 202:113975. [PMID: 35042131 PMCID: PMC8741629 DOI: 10.1016/j.bios.2022.113975] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Revised: 12/31/2021] [Accepted: 01/06/2022] [Indexed: 12/21/2022]
Abstract
Vertically paired electrodes (VPEs) with multiple electrode pairs were developed for the enhancement of capacitive measurements by optimizing the electrode gap and number of electrode pairs. The electrode was fabricated using a conductive polymer layer of PEDOT:PSS instead of Ag and Pt metal electrodes to increase the VPE fabrication yield because the PEDOT:PSS layer could be effectively etched using a reactive dry etching process. In this study, sensitivity enhancement was realized by decreasing the electrode gap and increasing the number of VPE electrode pairs. Such an increase in sensitivity according to the electrode gap and the number of electrode pairs was estimated using a model analyte for an immunoassay. Additionally, a computer simulation was performed using VPEs with different electrode gaps and numbers of VPE electrode pairs. Finally, VPEs with multiple electrode pairs were applied for SARS-CoV-2 nucleoprotein (NP) detection. The capacitive biosensor based on the VPE with immobilized anti-SARS-CoV-2 NP was applied for the specific detection of SARS-CoV-2 in viral cultures. Using viral cultures of SARS-CoV-2, SARS-CoV, MERS-CoV, and CoV-strain 229E, the limit of detection (LOD) was estimated to satisfy the cutoff value (dilution factor of 1/800) for the medical diagnosis of COVID-19, and the assay results from the capacitive biosensor were compared with commercial rapid kit based on a lateral flow immunoassay.
Collapse
|