1
|
Machleid R, Hoehse M, Scholze S, Mazarakis K, Nilsson D, Johansson E, Zehe C, Trygg J, Grimm C, Surowiec I. Feasibility and performance of cross-clone Raman calibration models in CHO cultivation. Biotechnol J 2024; 19:e2300289. [PMID: 38015079 DOI: 10.1002/biot.202300289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Revised: 10/30/2023] [Accepted: 11/21/2023] [Indexed: 11/29/2023]
Abstract
Raman spectroscopy is widely used in monitoring and controlling cell cultivations for biopharmaceutical drug manufacturing. However, its implementation for culture monitoring in the cell line development stage has received little attention. Therefore, the impact of clonal differences, such as productivity and growth, on the prediction accuracy and transferability of Raman calibration models is not yet well described. Raman OPLS models were developed for predicting titer, glucose and lactate using eleven CHO clones from a single cell line. These clones exhibited diverse productivity and growth rates. The calibration models were evaluated for clone-related biases using clone-wise linear regression analysis on cross validated predictions. The results revealed that clonal differences did not affect the prediction of glucose and lactate, but titer models showed a significant clone-related bias, which remained even after applying variable selection methods. The bias was associated with clonal productivity and lead to increased prediction errors when titer models were transferred to cultivations with productivity levels outside the range of their training data. The findings demonstrate the feasibility of Raman-based monitoring of glucose and lactate in cell line development with high accuracy. However, accurate titer prediction requires careful consideration of clonal characteristics during model development.
Collapse
Affiliation(s)
- Rafael Machleid
- Sartorius Stedim Biotech GmbH, Göttingen, Germany
- Computational Life Science Cluster (CLiC), Umeå University, Umeå, Sweden
| | - Marek Hoehse
- Sartorius Stedim Biotech GmbH, Göttingen, Germany
| | | | | | - David Nilsson
- Computational Life Science Cluster (CLiC), Umeå University, Umeå, Sweden
| | | | | | - Johan Trygg
- Computational Life Science Cluster (CLiC), Umeå University, Umeå, Sweden
- Sartorius Corporate Research, Umeå, Sweden
| | | | | |
Collapse
|
2
|
Tanemura H, Kitamura R, Yamada Y, Hoshino M, Kakihara H, Nonaka K. Comprehensive modeling of cell culture profile using Raman spectroscopy and machine learning. Sci Rep 2023; 13:21805. [PMID: 38071246 PMCID: PMC10710501 DOI: 10.1038/s41598-023-49257-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Accepted: 12/06/2023] [Indexed: 12/18/2023] Open
Abstract
Chinese hamster ovary (CHO) cells are widely utilized in the production of antibody drugs. To ensure the production of large quantities of antibodies that meet the required specifications, it is crucial to monitor and control the levels of metabolites comprehensively during CHO cell culture. In recent years, continuous analysis methods employing on-line/in-line techniques using Raman spectroscopy have attracted attention. While these analytical methods can nondestructively monitor culture data, constructing a highly accurate measurement model for numerous components is time-consuming, making it challenging to implement in the rapid research and development of pharmaceutical manufacturing processes. In this study, we developed a comprehensive, simple, and automated method for constructing a Raman model of various components measured by LC-MS and other techniques using machine learning with Python. Preprocessing and spectral-range optimization of data for model construction (partial least square (PLS) regression) were automated and accelerated using Bayes optimization. Subsequently, models were constructed for each component using various model construction techniques, including linear regression, ridge regression, XGBoost, and neural network. This enabled the model accuracy to be improved compared with PLS regression. This automated approach allows continuous monitoring of various parameters for over 100 components, facilitating process optimization and process monitoring of CHO cells.
Collapse
Affiliation(s)
- Hiroki Tanemura
- Biologics Technology Research Laboratories I, Biologics Division, Daiichi Sankyo Co., Ltd., 2716-1, Aza Kurakake, Oaza Akaiwa, Chiyoda-Machi, Oura-Gun, Gunma, 370-0503, Japan.
| | - Ryunosuke Kitamura
- Biologics Technology Research Laboratories I, Biologics Division, Daiichi Sankyo Co., Ltd., 2716-1, Aza Kurakake, Oaza Akaiwa, Chiyoda-Machi, Oura-Gun, Gunma, 370-0503, Japan
| | - Yasuko Yamada
- Analytical & Quality Evaluation Research Laboratories, Pharmaceutical Technology Division, Daiichi Sankyo Co., Ltd., 1-12-1, Shinomiya, Hiratsuka, Kanagawa, 254-0014, Japan
| | - Masato Hoshino
- Biologics Technology Research Laboratories I, Biologics Division, Daiichi Sankyo Co., Ltd., 2716-1, Aza Kurakake, Oaza Akaiwa, Chiyoda-Machi, Oura-Gun, Gunma, 370-0503, Japan
| | - Hirofumi Kakihara
- Biologics Technology Research Laboratories I, Biologics Division, Daiichi Sankyo Co., Ltd., 2716-1, Aza Kurakake, Oaza Akaiwa, Chiyoda-Machi, Oura-Gun, Gunma, 370-0503, Japan
| | - Koichi Nonaka
- Biologics Division, Daiichi Sankyo Co., Ltd., 2716-1, Aza Kurakake, Oaza Akaiwa, Chiyoda-Machi, Oura-Gun, Gunma, 370-0503, Japan
| |
Collapse
|
3
|
Li X. Recent applications of quantitative mass spectrometry in biopharmaceutical process development and manufacturing. J Pharm Biomed Anal 2023; 234:115581. [PMID: 37494866 DOI: 10.1016/j.jpba.2023.115581] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 06/27/2023] [Accepted: 07/12/2023] [Indexed: 07/28/2023]
Abstract
Biopharmaceutical products have seen rapid growth over the past few decades and continue to dominate the global pharmaceutical market. Aligning with the quality by design (QbD) framework and realization, recent advances in liquid chromatography-mass spectrometry (LC-MS) instrumentation and related techniques have enhanced biopharmaceutical characterization capabilities and have supported an increased development of biopharmaceutical products. Beyond its routine qualitative characterization, the quantitative feature of LC-MS has unique applications in biopharmaceutical process development and manufacturing. This review describes the recent applications and implications of the advancement of quantitative MS methods in biopharmaceutical process development, and characterization of biopharmaceutical product, product-related variants, and process-related impurities. We also provide insights on the emerging applications of quantitative MS in the lifecycle of biopharmaceutical product development including quality control in the Good Manufacturing Practice (GMP) environment and process analytical technology (PAT) practices during process development and manufacturing. Through collaboration with instrument and software vendors and regulatory agencies, we envision broader adoption of phase-appropriate quantitative MS-based methods for the analysis of biopharmaceutical products, which in turn has the potential to enable manufacture of higher quality products for patients.
Collapse
Affiliation(s)
- Xuanwen Li
- Analytical Research and Development, MRL, Merck & Co., Inc., 126 E. Lincoln Avenue, Rahway, NJ 07065, USA.
| |
Collapse
|
4
|
Mirveis Z, Howe O, Cahill P, Patil N, Byrne HJ. Monitoring and modelling the glutamine metabolic pathway: a review and future perspectives. Metabolomics 2023; 19:67. [PMID: 37482587 PMCID: PMC10363518 DOI: 10.1007/s11306-023-02031-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Accepted: 07/03/2023] [Indexed: 07/25/2023]
Abstract
BACKGROUND Analysis of the glutamine metabolic pathway has taken a special place in metabolomics research in recent years, given its important role in cell biosynthesis and bioenergetics across several disorders, especially in cancer cell survival. The science of metabolomics addresses the intricate intracellular metabolic network by exploring and understanding how cells function and respond to external or internal perturbations to identify potential therapeutic targets. However, despite recent advances in metabolomics, monitoring the kinetics of a metabolic pathway in a living cell in situ, real-time and holistically remains a significant challenge. AIM This review paper explores the range of analytical approaches for monitoring metabolic pathways, as well as physicochemical modeling techniques, with a focus on glutamine metabolism. We discuss the advantages and disadvantages of each method and explore the potential of label-free Raman microspectroscopy, in conjunction with kinetic modeling, to enable real-time and in situ monitoring of the cellular kinetics of the glutamine metabolic pathway. KEY SCIENTIFIC CONCEPTS Given its important role in cell metabolism, the ability to monitor and model the glutamine metabolic pathways are highlighted. Novel, label free approaches have the potential to revolutionise metabolic biosensing, laying the foundation for a new paradigm in metabolomics research and addressing the challenges in monitoring metabolic pathways in living cells.
Collapse
Affiliation(s)
- Zohreh Mirveis
- FOCAS Research Institute, Technological University Dublin, City Campus, Camden Row, Dublin 8, Ireland.
- School of Physics and Optometric & Clinical Sciences, Technological University Dublin, City Campus, Grangegorman, Dublin 7, Ireland.
| | - Orla Howe
- School of Biological, Health and Sport Sciences, Technological University Dublin, City Campus, Grangegorman, Dublin 7, Ireland
| | - Paul Cahill
- School of Biotechnology, Dublin City University, Glasnevin, Dublin 9, Ireland
| | - Nitin Patil
- FOCAS Research Institute, Technological University Dublin, City Campus, Camden Row, Dublin 8, Ireland
- School of Physics and Optometric & Clinical Sciences, Technological University Dublin, City Campus, Grangegorman, Dublin 7, Ireland
| | - Hugh J Byrne
- FOCAS Research Institute, Technological University Dublin, City Campus, Camden Row, Dublin 8, Ireland
| |
Collapse
|
5
|
Tomažič S, Škrjanc I. Halfway to Automated Feeding of Chinese Hamster Ovary Cells. SENSORS (BASEL, SWITZERLAND) 2023; 23:6618. [PMID: 37514911 PMCID: PMC10383754 DOI: 10.3390/s23146618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2023] [Revised: 07/14/2023] [Accepted: 07/21/2023] [Indexed: 07/30/2023]
Abstract
This paper presents a comprehensive study on the development of models and soft sensors required for the implementation of the automated bioreactor feeding of Chinese hamster ovary (CHO) cells using Raman spectroscopy and chemometric methods. This study integrates various methods, such as partial least squares regression and variable importance in projection and competitive adaptive reweighted sampling, and highlights their effectiveness in overcoming challenges such as high dimensionality, multicollinearity and outlier detection in Raman spectra. This paper emphasizes the importance of data preprocessing and the relationship between independent and dependent variables in model construction. It also describes the development of a simulation environment whose core is a model of CHO cell kinetics. The latter allows the development of advanced control algorithms for nutrient dosing and the observation of the effects of different parameters on the growth and productivity of CHO cells. All developed models were validated and demonstrated to have a high robustness and predictive accuracy, which were reflected in a 40% reduction in the root mean square error compared to established methods. The results of this study provide valuable insights into the practical application of these methods in the field of monitoring and automated cell feeding and make an important contribution to the further development of process analytical technology in the bioprocess industry.
Collapse
Affiliation(s)
- Simon Tomažič
- Faculty of Electrical Engineering, University of Ljubljana, 1000 Ljubljana, Slovenia
| | - Igor Škrjanc
- Faculty of Electrical Engineering, University of Ljubljana, 1000 Ljubljana, Slovenia
| |
Collapse
|