1
|
Tripathy RK, Pande AH. Molecular and functional insight into anti-EGFR nanobody: Theranostic implications for malignancies. Life Sci 2024; 345:122593. [PMID: 38554946 DOI: 10.1016/j.lfs.2024.122593] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2024] [Revised: 02/27/2024] [Accepted: 03/24/2024] [Indexed: 04/02/2024]
Abstract
Targeted therapy and imaging are the most popular techniques for the intervention and diagnosis of cancer. A potential therapeutic target for the treatment of cancer is the epidermal growth factor receptor (EGFR), primarily for glioblastoma, lung, and breast cancer. Over-production of ligand, transcriptional up-regulation due to autocrine/paracrine signalling, or point mutations at the genomic locus may contribute to the malfunction of EGFR in malignancies. This exploit makes use of EGFR, an established biomarker for cancer diagnostics and treatment. Despite considerable development in the last several decades in making EGFR inhibitors, they are still not free from limitations like toxicity and a short serum half-life. Nanobodies and antibodies share similar binding properties, but nanobodies have the additional advantage that they can bind to antigenic epitopes deep inside the target that conventional antibodies are unable to access. For targeted therapy, anti-EGFR nanobodies can be conjugated to various molecules such as drugs, peptides, toxins and photosensitizers. These nanobodies can be designed as novel immunoconjugates using the universal modular antibody-based platform technology (UniCAR). Furthermore, Anti-EGFR nanobodies can be expressed in neural stem cells and visualised by effective fluorescent and radioisotope labelling.
Collapse
Affiliation(s)
- Rajan K Tripathy
- Department of Biotechnology, National Institute of Pharmaceutical Education and Research (NIPER), Sector 67, S.A.S. Nagar, (Mohali) 160062, Punjab, India
| | - Abhay H Pande
- Department of Biotechnology, National Institute of Pharmaceutical Education and Research (NIPER), Sector 67, S.A.S. Nagar, (Mohali) 160062, Punjab, India.
| |
Collapse
|
2
|
Saway BF, Courtney J, Barley J, Frankel B, Hofstetter C, Kalhorn S. Contrast enhanced ultrasound for traumatic spinal cord injury: an overview of current and future applications. Spinal Cord Ser Cases 2024; 10:31. [PMID: 38664470 PMCID: PMC11045808 DOI: 10.1038/s41394-024-00644-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2024] [Revised: 04/08/2024] [Accepted: 04/17/2024] [Indexed: 04/28/2024] Open
Abstract
STUDY DESIGN Systematic review. OBJECTIVE Contrast-enhanced ultrasound (CEUS) is an imaging modality that has only recently seen neurosurgical application. CEUS uses inert microbubbles to intraoperatively visualize vasculature and perfusion of the brain and spinal cord in real time. Observation and augmentation of spinal cord perfusion is vital component of the management of traumatic spinal cord injury, yet there are limited imaging modalities to evaluate spinal cord perfusion. CEUS provides an intraoperative imaging tool to evaluate spinal cord perfusion in real time. The objective of this review is to evaluate the current literature on the various applications and benefits of CEUS in traumatic spinal cord injury. SETTING South Carolina, USA. METHODS This review was written according to the PRISMA 2020 guidelines. RESULTS 143 articles were found in our literature search, with 46 of them being unique. After excluding articles for relevance to CEUS and spinal cord injury, we were left with 10 papers. Studies in animal models have shown CEUS to be an effective non-invasive imaging modality that can detect perfusion changes of injured spinal cords in real time. CONCLUSION This imaging modality can provide object perfusion data of the nidus of injury, surrounding penumbra and healthy neural tissue in a traumatized spinal cord. Investigation in its use in humans is ongoing and remains promising to be an effective diagnostic and prognostic tool for those suffering from spinal cord injury.
Collapse
Affiliation(s)
- Brian Fabian Saway
- Medical University of South Carolina, Department of Neurosurgery, Charleston, SC, 29425, USA.
| | - James Courtney
- Florida State University College of Medicine, Tallahassee, FL, 32303, USA
| | - Jessica Barley
- Medical University of South Carolina, Department of Neurosurgery, Charleston, SC, 29425, USA
| | - Bruce Frankel
- Southern Illinois University School of Medicine, Department of Neurosurgery, Springfield, IL, 62702, USA
| | | | - Stephen Kalhorn
- Medical University of South Carolina, Department of Neurosurgery, Charleston, SC, 29425, USA
| |
Collapse
|
3
|
Li P, Du P, Peng J, Zhao Z, Li H, Yu W, Wang S, Liu L. Pharmacokinetics and pharmacodynamics of perfluoropropane after intra-venous bolus injection of perflutren lipid microsphere injection (DEFINITY®) in healthy Chinese volunteers. BMC Pharmacol Toxicol 2024; 25:6. [PMID: 38167238 PMCID: PMC10763448 DOI: 10.1186/s40360-023-00729-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2023] [Accepted: 12/27/2023] [Indexed: 01/05/2024] Open
Abstract
BACKGROUND AND OBJECTIVE Definity is an ultrasound contrast agent consisting of phospholipids-encapsulated perfluoropropane (PFP), also known as perflutren, microspheres, which is initially designed to enhance echocardiographic ultrasound images. With no pharmacologic action, Definity can increase the backscatter of ultrasound resulting enhanced ultrasound signals. The objective of this study was to determine the pharmacokinetics (PKs), Pharmacodynamics (PDs) and safety of Definity in healthy male and female Chinese volunteers. METHODS A simple GC-MS method was developed and applied to simultaneously quantify PFP both in human whole blood and in expired air using Perfluorobutane (PFB) as internal standard. Meanwhile, the blood microbubble Doppler intensities were continuously monitored as companion PDs by a Doppler ultrasonography system using a non-imaging method. RESULTS After intravenous infusion of 10 µL/kg of PFP within 30 seconds, the mean AUClast of the pharmacokinetic analysis set was 0.000653 (uL/mL)*min, the average AUC∞ was 0.001051 (uL/mL)*min. The main coefficient of variation of parameters were within 30%. In this trial, the blood drug concentration of female subjects was lower than that of males. Female Cmax, AUClast and AUC∞ were lower than males', Tmax and t1/2 was close to males', Vss and CL were slightly higher than males'. The concentration of PFP in the expired air of the subject reached the maximum value 1-2 min after administration and the PFP accumulation curve in the expired air began to become flat at 9.5-11 min after administration. The PFP in the expired air at the last sampling point of most subjects was still measurable. The results of the analysis showed that female subjects had slightly more and faster PFP excretion via the lungs than males. The change of blood drug concentration in this trial was related to the change process of Doppler signal intensity. The trend of the two was close, but the peak time of blood drug concentration was slightly delayed compared with the peak time of the Doppler signal intensity. The results showed that female tmax-pd, t10 was earlier than male, and women have lower AUCpd than men. CONCLUSION The pharmacokinetics and pharmacodynamics of Definity in blood and expired air were systematically evaluated for the first time in this study. The PK/PD analysis results of this trial showed that the change of blood concentration was related to the change process of Doppler signal intensity, the trend of the two was close and expired air are the main excretion pathways of Definity. Definity was well tolerated by all subjects in the trial. TRIAL REGISTRATION This study was registered on 08 December 2017 at the Chinese Clinical Trial Registry (CTR20171087).
Collapse
Affiliation(s)
- Pengfei Li
- Department of Pharmacy, Beijing An Ding Hospital, Capital Medical University, No.5 Ankang Hutong, Xicheng District, Beijing, 100088, China.
- Phase I Clinical Trial Unit, Beijing Chao-Yang Hospital, Capital Medical University, No.8 Gongti South Road, Chaoyang District, Beijing, 100020, China.
| | - Ping Du
- Phase I Clinical Trial Unit, Beijing Chao-Yang Hospital, Capital Medical University, No.8 Gongti South Road, Chaoyang District, Beijing, 100020, China
| | - Jun Peng
- Guoke Excellence (Beijing) Medicine Technology Research Co., Ltd, No.18 Zhonghe street, Daxing District, Beijing, 100176, China
| | - Zhixia Zhao
- Department of Pharmacy, China-Japan Friendship Hospital, No.2 Yinghuayuan East Street, Chaoyang District, Beijing, 100029, China
| | - Huiling Li
- Phase I Clinical Trial Unit, Beijing Chao-Yang Hospital, Capital Medical University, No.8 Gongti South Road, Chaoyang District, Beijing, 100020, China
| | - Weiyue Yu
- Phase I Clinical Trial Unit, Beijing Chao-Yang Hospital, Capital Medical University, No.8 Gongti South Road, Chaoyang District, Beijing, 100020, China
| | - Shumin Wang
- Phase I Clinical Trial Unit, Beijing Chao-Yang Hospital, Capital Medical University, No.8 Gongti South Road, Chaoyang District, Beijing, 100020, China.
| | - Lihong Liu
- Department of Pharmacy, China-Japan Friendship Hospital, No.2 Yinghuayuan East Street, Chaoyang District, Beijing, 100029, China.
| |
Collapse
|
4
|
Aziz MU, Eisenbrey JR, Deganello A, Zahid M, Sharbidre K, Sidhu P, Robbin ML. Microvascular Flow Imaging: A State-of-the-Art Review of Clinical Use and Promise. Radiology 2022; 305:250-264. [PMID: 36165794 PMCID: PMC9619200 DOI: 10.1148/radiol.213303] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2021] [Revised: 06/08/2022] [Accepted: 06/13/2022] [Indexed: 11/11/2022]
Abstract
Vascular imaging with color and power Doppler is a useful tool in the assessment of various disease processes. Assessment of blood flow, from infarction and ischemia to hyperemia, in organs, neoplasms, and vessels, is used in nearly every US investigation. Recent developments in this area are sensitive to small-vessel low velocity flow without use of intravenous contrast agents, known as microvascular flow imaging (MVFI). MVFI is more sensitive in detection of small vessels than color, power, and spectral Doppler, reducing the need for follow-up contrast-enhanced US (CEUS), CT, and MRI, except when arterial and venous wash-in and washout characteristics would be helpful in diagnosis. Varying clinical applications of MVFI are reviewed in adult and pediatric populations, including its technical underpinnings. MVFI shows promise in assessment of several conditions including benign and malignant lesions in the liver and kidney, acute pathologic abnormalities in the gallbladder and testes, and superficial lymph nodes. Future potential of MVFI in different conditions (eg, endovascular repair) is discussed. Finally, clinical cases in which MVFI correlated and potentially obviated additional CEUS, CT, or MRI are shown.
Collapse
Affiliation(s)
- Muhammad Usman Aziz
- From the Department of Radiology, University of Alabama at
Birmingham, 619 S 19th St, Suite JTN361, Birmingham, AL 35233 (M.U.A., M.Z.,
K.S., M.L.R.); Department of Radiology, Thomas Jefferson University,
Philadelphia, Pa (J.R.E.); and Department of Radiology, King’s College
London, King’s College Hospital, London, UK (A.D., P.S.)
| | - John R. Eisenbrey
- From the Department of Radiology, University of Alabama at
Birmingham, 619 S 19th St, Suite JTN361, Birmingham, AL 35233 (M.U.A., M.Z.,
K.S., M.L.R.); Department of Radiology, Thomas Jefferson University,
Philadelphia, Pa (J.R.E.); and Department of Radiology, King’s College
London, King’s College Hospital, London, UK (A.D., P.S.)
| | - Annamaria Deganello
- From the Department of Radiology, University of Alabama at
Birmingham, 619 S 19th St, Suite JTN361, Birmingham, AL 35233 (M.U.A., M.Z.,
K.S., M.L.R.); Department of Radiology, Thomas Jefferson University,
Philadelphia, Pa (J.R.E.); and Department of Radiology, King’s College
London, King’s College Hospital, London, UK (A.D., P.S.)
| | - Mohd Zahid
- From the Department of Radiology, University of Alabama at
Birmingham, 619 S 19th St, Suite JTN361, Birmingham, AL 35233 (M.U.A., M.Z.,
K.S., M.L.R.); Department of Radiology, Thomas Jefferson University,
Philadelphia, Pa (J.R.E.); and Department of Radiology, King’s College
London, King’s College Hospital, London, UK (A.D., P.S.)
| | - Kedar Sharbidre
- From the Department of Radiology, University of Alabama at
Birmingham, 619 S 19th St, Suite JTN361, Birmingham, AL 35233 (M.U.A., M.Z.,
K.S., M.L.R.); Department of Radiology, Thomas Jefferson University,
Philadelphia, Pa (J.R.E.); and Department of Radiology, King’s College
London, King’s College Hospital, London, UK (A.D., P.S.)
| | - Paul Sidhu
- From the Department of Radiology, University of Alabama at
Birmingham, 619 S 19th St, Suite JTN361, Birmingham, AL 35233 (M.U.A., M.Z.,
K.S., M.L.R.); Department of Radiology, Thomas Jefferson University,
Philadelphia, Pa (J.R.E.); and Department of Radiology, King’s College
London, King’s College Hospital, London, UK (A.D., P.S.)
| | - Michelle L. Robbin
- From the Department of Radiology, University of Alabama at
Birmingham, 619 S 19th St, Suite JTN361, Birmingham, AL 35233 (M.U.A., M.Z.,
K.S., M.L.R.); Department of Radiology, Thomas Jefferson University,
Philadelphia, Pa (J.R.E.); and Department of Radiology, King’s College
London, King’s College Hospital, London, UK (A.D., P.S.)
| |
Collapse
|
5
|
Maksymov IS, Huy Nguyen BQ, Suslov SA. Biomechanical Sensing Using Gas Bubbles Oscillations in Liquids and Adjacent Technologies: Theory and Practical Applications. BIOSENSORS 2022; 12:624. [PMID: 36005019 PMCID: PMC9406219 DOI: 10.3390/bios12080624] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Revised: 08/06/2022] [Accepted: 08/07/2022] [Indexed: 11/17/2022]
Abstract
Gas bubbles present in liquids underpin many natural phenomena and human-developed technologies that improve the quality of life. Since all living organisms are predominantly made of water, they may also contain bubbles-introduced both naturally and artificially-that can serve as biomechanical sensors operating in hard-to-reach places inside a living body and emitting signals that can be detected by common equipment used in ultrasound and photoacoustic imaging procedures. This kind of biosensor is the focus of the present article, where we critically review the emergent sensing technologies based on acoustically driven oscillations of bubbles in liquids and bodily fluids. This review is intended for a broad biosensing community and transdisciplinary researchers translating novel ideas from theory to experiment and then to practice. To this end, all discussions in this review are written in a language that is accessible to non-experts in specific fields of acoustics, fluid dynamics and acousto-optics.
Collapse
Affiliation(s)
- Ivan S. Maksymov
- Optical Sciences Centre, Swinburne University of Technology, Hawthorn, VIC 3122, Australia
| | - Bui Quoc Huy Nguyen
- Optical Sciences Centre, Swinburne University of Technology, Hawthorn, VIC 3122, Australia
| | - Sergey A. Suslov
- Department of Mathematics, Swinburne University of Technology, Hawthorn, VIC 3122, Australia
| |
Collapse
|
6
|
Kosiol J, Keiler A, Loizides A, Gruber H, Henninger B, Bölderl A, Gruber L. Operative versus conservative treatment of acute Achilles tendon ruptures: preliminary results of clinical outcome, kinematic MRI and contrast-enhanced ultrasound. Arch Orthop Trauma Surg 2022; 143:2455-2465. [PMID: 35567608 PMCID: PMC10110640 DOI: 10.1007/s00402-022-04457-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/04/2022] [Accepted: 04/15/2022] [Indexed: 12/28/2022]
Abstract
INTRODUCTION There is no uniform consensus on the gold standard therapy for acute Achilles tendon rupture. The aim of this pilot study was to compare operative and conservative treatment regarding imaging findings and clinical outcome. MATERIALS AND METHODS Surgically or conservatively treated patients with acute Achilles tendon rupture were retrospectively evaluated. Differences in tendon length and diameter with and without load were analysed using kinematic MRI, tendon perfusion, structural alterations, movement and scar tissue by means of grey-scale and contrast-enhanced ultrasound (CEUS). Intra- and interobserver agreement were recorded. RESULTS No significant difference was detected regarding clinical outcome, B mode ultrasonography, contrast-enhanced sonography or MRI findings, although alterations in MRI-based measurements of tendon elasticity were found for both groups. Considerable elongation and thickening of the injured tendon were detected in both groups. CONCLUSION Both, conservative and surgical treatment showed comparable outcomes in our preliminary results and may suggest non-inferiority of a conservative approach.
Collapse
Affiliation(s)
- Juana Kosiol
- Department of Orthopaedics and Traumatology, Medical University of Innsbruck, Anichstrasse 35, 6020, Innsbruck, Austria
| | - Alexander Keiler
- Department of Orthopaedics and Traumatology, Medical University of Innsbruck, Anichstrasse 35, 6020, Innsbruck, Austria.
| | - Alexander Loizides
- Department of Radiology, Medical University of Innsbruck, Anichstrasse 35, 6020, Innsbruck, Austria
| | - Hannes Gruber
- Department of Radiology, Medical University of Innsbruck, Anichstrasse 35, 6020, Innsbruck, Austria
| | - Benjamin Henninger
- Department of Radiology, Medical University of Innsbruck, Anichstrasse 35, 6020, Innsbruck, Austria
| | - Andreas Bölderl
- Department of Orthopaedics and Traumatology, Medical University of Innsbruck, Anichstrasse 35, 6020, Innsbruck, Austria
| | - Leonhard Gruber
- Department of Radiology, Medical University of Innsbruck, Anichstrasse 35, 6020, Innsbruck, Austria
| |
Collapse
|
7
|
Kikuchi Y, Kanagawa T, Ayukai T. Physico-mathematical model for multiple ultrasound-contrast-agent microbubbles encapsulated by a visco-elastic shell: Effect of shell compressibility on ultrasound attenuation. Chem Eng Sci 2022. [DOI: 10.1016/j.ces.2022.117541] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
8
|
Felipe VB, Ananya B, Ying T, Qiang L, Ji-Bin L, John RE. Renal Contrast-enhanced Ultrasound: Clinical Applications and Emerging Researc. ADVANCED ULTRASOUND IN DIAGNOSIS AND THERAPY 2022; 6:129. [DOI: 10.37015/audt.2022.220036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/12/2024] Open
|
9
|
Highlights in ultrasound-targeted microbubble destruction-mediated gene/drug delivery strategy for treatment of malignancies. Int J Pharm 2021; 613:121412. [PMID: 34942327 DOI: 10.1016/j.ijpharm.2021.121412] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Revised: 12/06/2021] [Accepted: 12/17/2021] [Indexed: 01/05/2023]
Abstract
Ultrasound is one of the safest and most advanced medical imaging technologies that is widely used in clinical practice. Ultrasound microbubbles, traditionally used for contrast-enhanced imaging, are increasingly applied in Ultrasound-targeted Microbubble Destruction (UTMD) technology which enhances tissue and cell membrane permeability through cavitation and sonoporation, to result in a promising therapeutic gene/drug delivery strategy. Here, we review recent developments in the application of UTMD-mediated gene and drug delivery in the diagnosis and treatment of tumors, including the concept, mechanism of action, clinical application status, and advantages of UTMD. Furthermore, the future perspectives that should be paid more attention to in this field are prospected.
Collapse
|
10
|
Panfilova A, Chen P, van Sloun RJG, Wijkstra H, Postema M, Poortinga AT, Mischi M. Experimental acoustic characterization of an endoskeletal antibubble contrast agent: First results. Med Phys 2021; 48:6765-6780. [PMID: 34580883 PMCID: PMC9293338 DOI: 10.1002/mp.15242] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Revised: 09/03/2021] [Accepted: 09/07/2021] [Indexed: 11/11/2022] Open
Abstract
Purpose An antibubble is an encapsulated gas bubble with an incompressible inclusion inside the gas phase. Current‐generation ultrasound contrast agents are bubble‐based: they contain encapsulated gas bubbles with no inclusions. The objective of this work is to determine the linear and nonlinear responses of an antibubble contrast agent in comparison to two bubble‐based ultrasound contrast agents, that is, reference bubbles and SonoVueTM. Methods Side scatter and attenuation of the three contrast agents were measured, using single‐element ultrasound transducers, operating at 1.0, 2.25, and 3.5 MHz. The scatter measurements were performed at acoustic pressures of 200 and 300 kPa for 1.0 MHz, 300 kPa, and 450 kPa for 2.25 MHz, and 370 and 560 kPa for 3.5 MHz. Attenuation measurements were conducted at pressures of 13, 55, and 50 kPa for 1.0, 2.25, and 3.5 MHz, respectively. In addition, a dynamic contrast‐enhanced ultrasound measurement was performed, imaging the contrast agent flow through a vascular phantom with a commercial diagnostic linear array probe. Results Antibubbles generated equivalent or stronger harmonic signal, compared to bubble‐based ultrasound contrast agents. The second harmonic side‐scatter amplitude of the antibubble agent was up to 3 dB greater than that of reference bubble agent and up to 4 dB greater than that of SonoVueTM at the estimated concentration of 8×104 bubbles/mL. For ultrasound with a center transmit frequency of 1.0 MHz, the attenuation coefficient of the antibubble agent was 8.7 dB/cm, whereas the attenuation coefficient of the reference agent was 7.7 and 0.3 dB/cm for SonoVueTM. At 2.25 MHz, the attenuation coefficients were 9.7, 3.0, and 0.6 dB/cm, respectively. For 3.5 MHz, they were 4.4, 1.8, and 1.0 dB/cm, respectively. A dynamic contrast‐enhanced ultrasound recording showed the nonlinear signal of the antibubble agent to be 31% greater than for reference bubbles and 23% lower than SonoVueTM at a high concentration of 2×106 bubbles/mL. Conclusion Endoskeletal antibubbles generate comparable or greater higher harmonics than reference bubbles and SonoVueTM. As a result, antibubbles with liquid therapeutic agents inside the gas phase have high potential to become a traceable therapeutic agent.
Collapse
Affiliation(s)
- Anastasiia Panfilova
- Electrical Engineering Department, Faculty of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Peiran Chen
- Electrical Engineering Department, Faculty of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Ruud J G van Sloun
- Electrical Engineering Department, Faculty of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Hessel Wijkstra
- Electrical Engineering Department, Faculty of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.,Department of Urology, Amsterdam University Medical Centers location AMC, Amsterdam, The Netherlands
| | - Michiel Postema
- School of Electrical and Information Engineering, University of the Witwatersrand, Johannesburg, Braamfontein, South Africa.,BioMediTech, Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| | - Albert T Poortinga
- Mechanical Engineering Department, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Massimo Mischi
- Electrical Engineering Department, Faculty of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| |
Collapse
|
11
|
Guo B, Li Z, Tu P, Tang H, Tu Y. Molecular Imaging and Non-molecular Imaging of Atherosclerotic Plaque Thrombosis. Front Cardiovasc Med 2021; 8:692915. [PMID: 34291095 PMCID: PMC8286992 DOI: 10.3389/fcvm.2021.692915] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Accepted: 06/08/2021] [Indexed: 12/11/2022] Open
Abstract
Thrombosis in the context of atherosclerosis typically results in life-threatening consequences, including acute coronary events and ischemic stroke. As such, early detection and treatment of thrombosis in atherosclerosis patients is essential. Clinical diagnosis of thrombosis in these patients is typically based upon a combination of imaging approaches. However, conventional imaging modalities primarily focus on assessing the anatomical structure and physiological function, severely constraining their ability to detect early thrombus formation or the processes underlying such pathology. Recently, however, novel molecular and non-molecular imaging strategies have been developed to assess thrombus composition and activity at the molecular and cellular levels more accurately. These approaches have been successfully used to markedly reduce rates of atherothrombotic events in patients suffering from acute coronary syndrome (ACS) by facilitating simultaneous diagnosis and personalized treatment of thrombosis. Moreover, these modalities allow monitoring of plaque condition for preventing plaque rupture and associated adverse cardiovascular events in such patients. Sustained developments in molecular and non-molecular imaging technologies have enabled the increasingly specific and sensitive diagnosis of atherothrombosis in animal studies and clinical settings, making these technologies invaluable to patients' health in the future. In the present review, we discuss current progress regarding the non-molecular and molecular imaging of thrombosis in different animal studies and atherosclerotic patients.
Collapse
Affiliation(s)
- Bingchen Guo
- Department of Cardiology, The Second Affiliated Hospital of Harbin Medical University, Harbin, China
| | - Zhaoyue Li
- Department of Cardiology, The First Affiliated Hospital of Harbin Medical University, Harbin, China
| | - Peiyang Tu
- College of Clinical Medicine, Hubei University of Science and Technology, Xianning, China
| | - Hao Tang
- Department of Cardiology, The First Affiliated Hospital of Harbin Medical University, Harbin, China
| | - Yingfeng Tu
- Department of Cardiology, The First Affiliated Hospital of Harbin Medical University, Harbin, China
| |
Collapse
|
12
|
Nakamura I, Hatano E, Tada M, Kawabata Y, Tamagawa S, Kurimoto A, Iwama H, Toriguchi K, Sueoka H, Iida K, Yoshida M, Nishimura T, Iijima H. Enhanced patterns on intraoperative contrast-enhanced ultrasonography predict outcomes after curative liver resection in patients with hepatocellular carcinoma. Surg Today 2021; 51:764-776. [PMID: 32964250 DOI: 10.1007/s00595-020-02145-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2020] [Accepted: 09/04/2020] [Indexed: 12/14/2022]
Abstract
PURPOSE This study aimed to clarify what hepatocellular carcinoma (HCC) phenotype, as categorized by intraoperative contrast-enhanced ultrasonography (CEUS), showed a high risk of recurrence after hepatic resection. METHODS Patients who underwent initial curative hepatectomy with intraoperative CEUS for a single HCC nodule were retrospectively assigned to three patterns of fine (FI), vascular (VA), and irregular (IR) according to the maximum intensity projection pattern based on intraoperative CEUS. Staining was performed for Ki-67, pyruvate kinase type M2 (PKM2), and vascular endothelial growth factor (VEGF) to assess the tumor proliferative activity, tumor glucose metabolism, and angiogenesis, respectively. RESULTS Of 116 patients, 18, 50, and 48 were assigned to the FI, VA and IR patterns, respectively. IR patients demonstrated a significantly worse prognosis for both the recurrence-free survival (RFS) and overall survival (OS) (P = 0.0002, 0.0262, respectively) than did patients with other patterns. A multivariate analysis revealed an IR pattern in intraoperative CEUS to be an independent predictive factor for a poor RFS, and major hepatectomy and an IR pattern were independent predictive factors for a poor OS. An IR pattern was closely related to the tumor size (≥ 3.3 cm) and poor histological differentiation and showed a high Ki-67 index, low VEGF expression, and high PKM2 expression. CONCLUSION IR-pattern HCCs as classified by intraoperative CEUS may be associated with a higher risk of recurrence and worse outcomes in HCC patients after hepatic resection than other patterns.
Collapse
Affiliation(s)
- Ikuo Nakamura
- Department of Gastroenterological Surgery, Hyogo College of Medicine, Hyogo, Japan
| | - Etsuro Hatano
- Department of Gastroenterological Surgery, Hyogo College of Medicine, Hyogo, Japan.
| | - Masaharu Tada
- Department of Gastroenterological Surgery, Hyogo College of Medicine, Hyogo, Japan
| | - Yusuke Kawabata
- Department of Gastroenterological Surgery, Hyogo College of Medicine, Hyogo, Japan
| | - Shinjiro Tamagawa
- Department of Gastroenterological Surgery, Hyogo College of Medicine, Hyogo, Japan
| | - Ami Kurimoto
- Department of Gastroenterological Surgery, Hyogo College of Medicine, Hyogo, Japan
| | - Hideaki Iwama
- Department of Gastroenterological Surgery, Hyogo College of Medicine, Hyogo, Japan
| | - Kan Toriguchi
- Department of Gastroenterological Surgery, Hyogo College of Medicine, Hyogo, Japan
| | - Hideaki Sueoka
- Department of Gastroenterological Surgery, Hyogo College of Medicine, Hyogo, Japan
| | - Kenjiro Iida
- Department of Gastroenterological Surgery, Hyogo College of Medicine, Hyogo, Japan
| | - Masahiro Yoshida
- Ultrasound Imaging Center, Hyogo College of Medicine, Hyogo, Japan
| | - Takashi Nishimura
- Division of Hepatobiliary and Pancreatic Disease, Department of Internal Medicine, Hyogo College of Medicine, Hyogo, Japan
| | - Hiroko Iijima
- Division of Hepatobiliary and Pancreatic Disease, Department of Internal Medicine, Hyogo College of Medicine, Hyogo, Japan
| |
Collapse
|
13
|
Steinsvik EK, Hatlebakk JG, Hausken T, Nylund K, Gilja OH. Ultrasound imaging for assessing functions of the GI tract. Physiol Meas 2021; 42:024002. [PMID: 33434898 DOI: 10.1088/1361-6579/abdad7] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
OBJECTIVE In the following review we outline how ultrasound can be used to measure physiological processes in the gastrointestinal tract. APPROACH We have investigated the potential of ultrasound in assessing gastrointestinal physiology including original research regarding both basic methodology and clinical applications. MAIN RESULTS Our main findings show the use of ultrasound to study esophageal motility, measure volume and contractility of the stomach, assess motility, wall thickness, and perfusion of the small bowel, and evaluate wall vascularization and diameters of the large bowel. SIGNIFICANCE Ultrasound is a widely accessible technology that can be used for both scientific and clinical purposes. Being radiation-free and user friendly, the examination can be frequently repeated enabling longitudinal studies. Furthermore, it does not influence normal GI physiology, thus being useful to estimate motility and subtle changes in physiology. Accordingly, ultrasound scanning and physiological measurements may make a big difference for the scientist and the doctor; and for the patients who receive an efficient work-up.
Collapse
Affiliation(s)
- Elisabeth K Steinsvik
- National Center for Ultrasound in Gastroenterology, Department of Medicine, Haukeland University Hospital, Bergen, Norway
- Department of Clinical Medicine, University of Bergen, Bergen, Norway
| | - Jan Gunnar Hatlebakk
- National Center for Ultrasound in Gastroenterology, Department of Medicine, Haukeland University Hospital, Bergen, Norway
- Department of Clinical Medicine, University of Bergen, Bergen, Norway
| | - Trygve Hausken
- National Center for Ultrasound in Gastroenterology, Department of Medicine, Haukeland University Hospital, Bergen, Norway
- Department of Clinical Medicine, University of Bergen, Bergen, Norway
| | - Kim Nylund
- National Center for Ultrasound in Gastroenterology, Department of Medicine, Haukeland University Hospital, Bergen, Norway
- Department of Clinical Medicine, University of Bergen, Bergen, Norway
| | - Odd Helge Gilja
- National Center for Ultrasound in Gastroenterology, Department of Medicine, Haukeland University Hospital, Bergen, Norway
- Department of Clinical Medicine, University of Bergen, Bergen, Norway
| |
Collapse
|
14
|
Wang L, Wang P, Li X, Dong Y, Wu S, Xu M, Chen X, Wang S, Zheng C, Zou C. Combination CTLA-4 immunoglobulin treatment and ultrasound microbubble-mediated exposure improve renal function in a rat model of diabetic nephropathy. Aging (Albany NY) 2021; 13:8524-8540. [PMID: 33714204 PMCID: PMC8034886 DOI: 10.18632/aging.202664] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2020] [Accepted: 02/01/2021] [Indexed: 12/17/2022]
Abstract
OBJECTIVE This study explored the therapeutic impact of combined cytotoxic T lymphocyte-associated antigen 4 immunoglobulin (CTLA-4-Ig) treatment and microbubble-mediated exposure in a rat model of diabetic nephropathy (DN). METHOD We treated rats using CTLA-4-Ig and/or microbubble exposure. At 8 weeks post-intervention, key parameters were evaluated including blood biochemistry, damage to renal tissue, renal parenchymal elasticity, ultrastructural changes in podocytes, and renal parenchymal expression of CD31, CD34, IL-6, Fn, Collagen I, Talin, Paxillin, α3β1, podocin, nephrin, and B7-1. RESULT We found that renal function in the rat model of DN can be significantly improved by CTLA-4-Ig and CTLA-4-Ig + ultrasound microbubble treatment. Treatment efficacy was associated with reductions in renal parenchymal hardness, decreases in podocyte reduction, decreased IL-6, Fn and Collagen I expression, increased Talin, Paxillin and α3β1 expression, elevated podocin and nephrin expression, and decreased B7-1 expression. In contrast, these treatments did not impact CD31 or CD34 expression within the renal parenchyma. CONCLUSION These findings clearly emphasize that CTLA-4-Ig can effectively prevent podocyte damage, inhibiting inflammation and fibrosis, and thereby treating and preventing DN. In addition, ultrasound microbubble exposure can improve the ability of CTLA-4-Ig to pass through the glomerular basement membrane in order to access podocytes such that combination CTLA-4-Ig + microbubble exposure treatment is superior to treatment with CTLA-4-Ig only.
Collapse
Affiliation(s)
- Liang Wang
- Department of Ultrasonic Diagnosis, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou 325027, Zhejiang, China
| | - Pengfei Wang
- Department of Ultrasonic Diagnosis, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou 325027, Zhejiang, China
| | - Xiuyun Li
- Department of Ultrasonic Diagnosis, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou 325027, Zhejiang, China
| | - Yanyan Dong
- Department of Ultrasonic Diagnosis, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou 325027, Zhejiang, China
| | - Senmin Wu
- Department of Ultrasonic Diagnosis, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou 325027, Zhejiang, China
| | - Maosheng Xu
- Department of Ultrasonic Diagnosis, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou 325027, Zhejiang, China
| | - Xiu Chen
- Department of Ultrasonic Diagnosis, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou 325027, Zhejiang, China
| | - Shijia Wang
- Department of Ultrasonic Diagnosis, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou 325027, Zhejiang, China
| | - Chao Zheng
- Department of Endocrinology, The Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou 310000, Zhejiang, China
| | - Chunpeng Zou
- Department of Ultrasonic Diagnosis, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou 325027, Zhejiang, China
| |
Collapse
|
15
|
Zhao M, Zhu Y, Zhang Y, Yang X, Duan Y, Chen Y, Sun Y. CDCP1-targeted nanoparticles encapsulating phase-shift perfluorohexan for molecular US imaging in vitro. Clin Hemorheol Microcirc 2020; 80:25-35. [PMID: 33185589 DOI: 10.3233/ch-200900] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Molecular targeted contrast-enhanced ultrasound (CEUS) imaging is a potential imaging strategy to improve the diagnostic accuracy of conventional ultrasound (US) imaging. US contrast agents are usually micrometer-sized and non-target gas bubbles while nano-sized and targeted agents containing phase-shift materials absorb more attractions for their size and the liquid core and excellent molecular imaging effect. METHODS PLGA12k-mPEG2k-NH2, DSPE-mPEG2k and perfluorohexan (PFH) were used to construct a new targeted ultrasound contrast agent with CUB domain-containing protein 1 (CDCP1) receptor for the detection and diagnosis of prostate cancer. The potential of tumor-targeted nanoparticles (CDCP1-targeted perfluorohexan-loaded phase-transitional nanoparticles, anti-CDCP1 NPs) as contrast agents for ultrasound (US) imaging was assessed in vitro. Moreover, studies on the cytotoxicity and the targeting ability of anti-CDCP1 NPs assisted by US were carried out. RESULTS The results showed that anti-CDCP1 NPs had low cytotoxicity, and with the increasing of polymer concentration in anti-CDCP1 NPs, the CEUS imaging of agent gradually enhanced, and enhanced imaging associated with the length of observing time. Furthermore, it was testified that anti-CDCP1 assisted the agent to target cells expressing CDCP1, which demonstrated the active targeting of anti-CDCP1 NPs in vitro. CONCLUSION All in all, the feasibility of using targeted anti-CDCP1 NPs to enhance ultrasound imaging has been demonstrated in vitro, which laid a solid foundation for molecular US imaging in vivo, and anti-CDCP1 NPs might have a great clinical application prospect.
Collapse
Affiliation(s)
- Meng Zhao
- State Key Laboratory of Oncogenes and Related Genes,Shanghai Cancer Institute, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, People's Republic of China
| | - Yunkai Zhu
- Department of Ultrasound, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, People's Republic of China
| | - Yanhua Zhang
- State Key Laboratory of Oncogenes and Related Genes,Shanghai Cancer Institute, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, People's Republic of China
| | - Xupeng Yang
- State Key Laboratory of Oncogenes and Related Genes,Shanghai Cancer Institute, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, People's Republic of China
| | - Yourong Duan
- State Key Laboratory of Oncogenes and Related Genes,Shanghai Cancer Institute, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, People's Republic of China
| | - Yaqing Chen
- Department of Ultrasound, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, People's Republic of China
| | - Ying Sun
- State Key Laboratory of Oncogenes and Related Genes,Shanghai Cancer Institute, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, People's Republic of China
| |
Collapse
|
16
|
Yoon MJ, Kim DH, Jung IY, Park SH. A laboratory study to detect simulated pulpal blood flow in extracted human teeth using ultrasound Doppler flowmetry. Int Endod J 2020; 54:231-240. [PMID: 32931061 DOI: 10.1111/iej.13410] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2020] [Accepted: 09/08/2020] [Indexed: 11/30/2022]
Abstract
AIM To develop a laboratory-based tooth model of simulated blood flow in teeth and evaluate it using ultrasound Doppler flowmetry (UDF). METHODOLOGY A laboratory-based tooth model for UDF was created based on a microfluidic experimental model proposed by Kim & Park (2016 a,b). Twenty-one maxillary or mandibular anterior human teeth within 1 month of extraction were used. Four holes were made in each tooth to fit 1.6-mm diameter polytetrafluoroethylene (PTFE) tubes: at the apical foramen, palatal surface in the centre of the crown, palatal surface apical to the cementoenamel junction (CEJ) and the root centre. Fluid mimicking pulsating blood was pumped (pressure range: 0-200 mbar, flow rate range: 0-80 μL min-1 ) into the apical foramen via the PTFE tubes, which exited the tooth through the palatal surface in the centre of the crown (control group), palatal surface below the CEJ (group 1) and the palatal surface at the mid-root level (group 2). An UDF transducer of 20 MHz was placed at a 60° angle to the labial surface of tooth and was used to measure the fluid flow velocity (Vs, Vas, Vm, Vam, Vd, Vad and Vakd). The flow velocity of the different groups was compared using the Wilcoxon signed-rank test, with a 95% confidence level. RESULTS UDF facilitated the detection of the simulated pulpal blood flow in the control group and group 1, but not in group 2. The mean and standard deviations of Vas, Vam and Vakd were 0.921 ± 0.394, 0.479 ± 0.208 and 0.396 ± 0.220 cm s-1 , respectively, in the control group, and 0.865 ± 0.368, 0.424 ± 0.215 and 0.487 ± 0.279 cm s-1 , respectively, in group 1. The pulpal blood flow values of the control group and group 1 were not significantly different (p > 0.05). CONCLUSIONS This laboratory study revealed that ultrasound Doppler flowmetry enabled the detection of simulated blood flow below the level of the CEJ but not at the mid-root level.
Collapse
Affiliation(s)
- M J Yoon
- Department of Conservative Dentistry, Oral Science Research Center, College of Dentistry, Yonsei University, Seoul, Korea
| | - D H Kim
- Department of Conservative Dentistry, Oral Science Research Center, College of Dentistry, Yonsei University, Seoul, Korea
| | - I Y Jung
- Department of Conservative Dentistry, Oral Science Research Center, College of Dentistry, Yonsei University, Seoul, Korea
| | - S H Park
- Department of Conservative Dentistry, Oral Science Research Center, College of Dentistry, Yonsei University, Seoul, Korea
| |
Collapse
|
17
|
Er Saw P. BIOI Virtual Academic Series PART 1: Multidisciplinary Integration in Academia. BIO INTEGRATION 2020. [DOI: 10.15212/bioi-2020-0031] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
|
18
|
Bjånes T, Kotopoulis S, Murvold ET, Kamčeva T, Gjertsen BT, Gilja OH, Schjøtt J, Riedel B, McCormack E. Ultrasound- and Microbubble-Assisted Gemcitabine Delivery to Pancreatic Cancer Cells. Pharmaceutics 2020; 12:pharmaceutics12020141. [PMID: 32046005 PMCID: PMC7076495 DOI: 10.3390/pharmaceutics12020141] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2020] [Revised: 01/28/2020] [Accepted: 02/04/2020] [Indexed: 02/06/2023] Open
Abstract
Pancreatic ductal adenocarcinoma (PDAC) is a major cause of cancer death worldwide. Poor drug delivery to tumours is thought to limit chemotherapeutic treatment efficacy. Sonoporation combines ultrasound (US) and microbubbles to increase the permeability of cell membranes. We assessed gemcitabine uptake combined with sonoporation in vitro in three PDAC cell lines (BxPC-3, MIA PaCa-2 and PANC-1). Cells were cultured in hypoxic bioreactors, while gemcitabine incubation ± sonoporation was conducted in cells with operational or inhibited nucleoside membrane transporters. Intracellular active metabolite (dFdCTP), extracellular gemcitabine, and inactive metabolite (dFdU) concentrations were measured with liquid chromatography tandem mass spectrometry. Sonoporation with increasing US intensities resulted in decreasing extracellular gemcitabine concentrations in all three cell lines with inhibited membrane transporters. In cells with inhibited membrane transporters, without sonoporation, dFdCTP concentrations were reduced down to 10% of baseline. Sonoporation partially restored gemcitabine uptake in these cells, as indicated by a moderate increase in dFdCTP concentrations (up to 37% of baseline) in MIA PaCa-2 and PANC-1. In BxPC-3, gemcitabine was effectively inactivated to dFdU, which might represent a protective mechanism against dFdCTP accumulation in these cells. Intracellular dFdCTP concentrations did not change significantly following sonoporation in any of the cell lines with operational membrane transporters, indicating that the gemcitabine activation pathway may have been saturated with the drug. Sonoporation allowed a moderate increase in gemcitabine transmembrane uptake in all three cell lines, but pre-existing nucleoside transporters were the major determinants of gemcitabine uptake and retention.
Collapse
Affiliation(s)
- Tormod Bjånes
- Department of Medical Biochemistry and Pharmacology, Haukeland University Hospital, Bergen 5021, Norway; (T.K.); (J.S.); (B.R.)
- Department of Clinical Science, Faculty of Medicine, University of Bergen, Bergen 5021, Norway;
- Correspondence: (T.B.); (E.M.)
| | - Spiros Kotopoulis
- Phoenix Solutions AS, Ullernchausseen 64, 0379 Oslo, Norway;
- National Centre for Ultrasound in Gastroenterology, Haukeland University Hospital, Bergen 5021, Norway;
- Department of Clinical Medicine, University of Bergen, Bergen 5021, Norway
| | | | - Tina Kamčeva
- Department of Medical Biochemistry and Pharmacology, Haukeland University Hospital, Bergen 5021, Norway; (T.K.); (J.S.); (B.R.)
| | - Bjørn Tore Gjertsen
- Department of Clinical Science, Faculty of Medicine, University of Bergen, Bergen 5021, Norway;
- Department of Internal Medicine, Hematology Section, Haukeland University Hospital, Bergen 5021, Norway
| | - Odd Helge Gilja
- National Centre for Ultrasound in Gastroenterology, Haukeland University Hospital, Bergen 5021, Norway;
- Department of Clinical Medicine, University of Bergen, Bergen 5021, Norway
| | - Jan Schjøtt
- Department of Medical Biochemistry and Pharmacology, Haukeland University Hospital, Bergen 5021, Norway; (T.K.); (J.S.); (B.R.)
- Department of Clinical Science, Faculty of Medicine, University of Bergen, Bergen 5021, Norway;
| | - Bettina Riedel
- Department of Medical Biochemistry and Pharmacology, Haukeland University Hospital, Bergen 5021, Norway; (T.K.); (J.S.); (B.R.)
- Department of Clinical Science, Faculty of Medicine, University of Bergen, Bergen 5021, Norway;
| | - Emmet McCormack
- Department of Clinical Science, Faculty of Medicine, University of Bergen, Bergen 5021, Norway;
- Centre for Cancer Biomarkers CCBIO, Department of Clinical Science, University of Bergen, Bergen 5021, Norway
- Correspondence: (T.B.); (E.M.)
| |
Collapse
|
19
|
Lau C, Rivas M, Dinalo J, King K, Duddalwar V. Scoping Review of Targeted Ultrasound Contrast Agents in the Detection of Angiogenesis. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2020; 39:19-28. [PMID: 31237009 DOI: 10.1002/jum.15072] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2018] [Revised: 05/16/2019] [Accepted: 05/22/2019] [Indexed: 06/09/2023]
Abstract
A systematic search was conducted to categorize targeted ultrasound contrast agents (UCAs) used in cancer-related angiogenesis detection. We identified 15 unique contrast agents from 2008 to March 2018. Most primary research articles studied UCAs targeted to vascular endothelial growth factor receptor or αv β3 -integrin. Breast cancer and colon cancer are the most common neoplastic processes in which these agents were studied. BR55 (Bracco Research SA, Geneva, Switzerland), a vascular endothelial growth factor receptor-targeting UCA, is the first targeted UCA that has completed phase 0 trials. Our review identifies a gap in the literature regarding the application of targeted UCAs in cancer models beyond breast and colon cancers and identifies other promising UCAs.
Collapse
Affiliation(s)
- Christopher Lau
- Department of Radiology, Keck School of Medicine, California, Los Angeles, USA
| | - Marielena Rivas
- Department of Radiology, Keck School of Medicine, California, Los Angeles, USA
| | - Jennifer Dinalo
- Norris Medical Library, Keck School of Medicine, California, Los Angeles, USA
| | - Kevin King
- Department of Radiology, Keck School of Medicine, California, Los Angeles, USA
| | - Vinay Duddalwar
- Department of Radiology, Keck School of Medicine, California, Los Angeles, USA
| |
Collapse
|
20
|
Emanuel AL, Meijer RI, van Poelgeest E, Spoor P, Serné EH, Eringa EC. Contrast-enhanced ultrasound for quantification of tissue perfusion in humans. Microcirculation 2019; 27:e12588. [PMID: 31465606 PMCID: PMC7050534 DOI: 10.1111/micc.12588] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2019] [Revised: 08/21/2019] [Accepted: 08/26/2019] [Indexed: 12/17/2022]
Abstract
Contrast-enhanced ultrasound is an imaging technique that can be used to quantify microvascular blood volume and blood flow of vital organs in humans. It relies on the use of microbubble contrast agents and ultrasound-based imaging of microbubbles. Over the past decades, both ultrasound contrast agents and experimental techniques to image them have rapidly improved, as did experience among investigators and clinicians. However, these improvements have not yet resulted in uniform guidelines for CEUS when it comes to quantification of tissue perfusion in humans, preventing its uniform and widespread use in research settings. The objective of this review is to provide a methodological overview of CEUS and its development, the influences of hardware and software settings, type and dosage of ultrasound contrast agent, and method of analysis on CEUS-derived perfusion data. Furthermore, we will discuss organ-specific imaging challenges, advantages, and limitations of CEUS.
Collapse
Affiliation(s)
- Anna L Emanuel
- Department of Internal Medicine, Amsterdam University Medical Center, Location VU University Medical Centre, Amsterdam, The Netherlands
| | - Rick I Meijer
- Department of Internal Medicine, Amsterdam University Medical Center, Location VU University Medical Centre, Amsterdam, The Netherlands
| | - Erik van Poelgeest
- Department of Internal Medicine, Amsterdam University Medical Center, Location VU University Medical Centre, Amsterdam, The Netherlands.,Department of Physiology, Amsterdam University Medical Center, Location VU University Medical Centre, Amsterdam, The Netherlands
| | - Pien Spoor
- Department of Physiology, Amsterdam University Medical Center, Location VU University Medical Centre, Amsterdam, The Netherlands.,Department of Cardiology, Amsterdam University Medical Center, Location VU University Medical Centre, Amsterdam, The Netherlands
| | - Erik H Serné
- Department of Internal Medicine, Amsterdam University Medical Center, Location VU University Medical Centre, Amsterdam, The Netherlands
| | - Etto C Eringa
- Department of Physiology, Amsterdam University Medical Center, Location VU University Medical Centre, Amsterdam, The Netherlands
| |
Collapse
|
21
|
Kee ALY, Teo BM. Biomedical applications of acoustically responsive phase shift nanodroplets: Current status and future directions. ULTRASONICS SONOCHEMISTRY 2019; 56:37-45. [PMID: 31101274 DOI: 10.1016/j.ultsonch.2019.03.024] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/09/2019] [Revised: 03/08/2019] [Accepted: 03/22/2019] [Indexed: 05/19/2023]
Abstract
The evolution of ultrasonic contrast agents to enhance the reflectivity of structures in the human body has consolidated ultrasound's stance as a reliable diagnostic imaging modality. A significant development within this field includes the advent of liquid nanodroplets that are capable of vaporising into gaseous microbubbles upon ultrasonic irradiation. This literature review will therefore appraise and summarise the available literature on the generation of phase-shift nanodroplets, their formulations, applications, safety issues, future developments and any implications that may inhibit their clinical implementation. The main findings of this review affirm that phase change nanodroplets do indeed demonstrate functionality in drug delivery and targeting and characterisation of tumours. Its bioeffects however, have not yet been extensively researched, prompting further exploration into how bubble size can be controlled once it has vaporised into microbubbles and the resulting complications. As such, future research should be directed towards determining the safety, longevity and suitability of phase-shift nanodroplets over contrast agents in current clinical use.
Collapse
Affiliation(s)
- Allison Loo Yong Kee
- Department of Medical Imaging and Radiation Sciences, Monash University, 10 Chancellors Walk, Clayton, Victoria 3800, Australia
| | - Boon Mian Teo
- School of Chemistry, Monash University, 19 Rainforest Walk, Clayton, Victoria 3800, Australia.
| |
Collapse
|
22
|
Hall RL, Juan-Sing ZD, Hoyt K, Sirsi SR. Formulation and Characterization of Chemically Cross-linked Microbubble Clusters. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2019; 35:10977-10986. [PMID: 31310715 PMCID: PMC7061884 DOI: 10.1021/acs.langmuir.9b00475] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
The purpose of this study is to introduce a new concept of chemically cross-linked microbubble clusters (CCMCs), which are individual microbubble ultrasound contrast agents (UCAs) physically tethered together. We demonstrate a facile means of their production, characterize their size and stability, and describe how they can potentially be used in biomedical applications. By tethering UCAs together into CCMCs, we propose that novel methods of ultrasound mediated imaging and therapy can be developed through unique interbubble interactions in an ultrasound field. One of the major challenges in generating CCMCs is controlling aggregate sizes and maintaining stability against Ostwald ripening and coalescence. In this study, we demonstrate that chemically cross-linked microbubble clusters can produce small (<10 μm) quasi-stable complexes that slowly fuse into bubbles with individual gas cores. Furthermore, we demonstrate that this process can be driven with low-intensity ultrasound pulses, enabling a rapid fusion of clusters which could potentially be used to develop novel ultrasound contrast imaging and drug delivery strategies in future studies. The development of novel microbubble clusters presents a simple yet robust process for generating novel UCAs with a design that could allow for more versatility in contrast-enhanced ultrasound (CEUS), molecular imaging, and drug delivery applications. Additionally, microbubble clustering is a unique way to control size, shell, and gas compositions that can be used to study bubble ripening and coalescence in a highly controlled environment or study the behavior of mixed-microbubble populations.
Collapse
Affiliation(s)
- Ronald L. Hall
- University of Texas at Dallas, Richardson, Texas, 75080, United States
| | | | - Kenneth Hoyt
- University of Texas at Dallas, Richardson, Texas, 75080, United States
- University of Texas Southwestern, Dallas, Texas, 75390, United States
| | - Shashank R. Sirsi
- University of Texas at Dallas, Richardson, Texas, 75080, United States
- University of Texas Southwestern, Dallas, Texas, 75390, United States
| |
Collapse
|
23
|
Roovers S, Segers T, Lajoinie G, Deprez J, Versluis M, De Smedt SC, Lentacker I. The Role of Ultrasound-Driven Microbubble Dynamics in Drug Delivery: From Microbubble Fundamentals to Clinical Translation. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2019; 35:10173-10191. [PMID: 30653325 DOI: 10.1021/acs.langmuir.8b03779] [Citation(s) in RCA: 118] [Impact Index Per Article: 19.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
In the last couple of decades, ultrasound-driven microbubbles have proven excellent candidates for local drug delivery applications. Besides being useful drug carriers, microbubbles have demonstrated the ability to enhance cell and tissue permeability and, as a consequence, drug uptake herein. Notwithstanding the large amount of evidence for their therapeutic efficacy, open issues remain. Because of the vast number of ultrasound- and microbubble-related parameters that can be altered and the variability in different models, the translation from basic research to (pre)clinical studies has been hindered. This review aims at connecting the knowledge gained from fundamental microbubble studies to the therapeutic efficacy seen in in vitro and in vivo studies, with an emphasis on a better understanding of the response of a microbubble upon exposure to ultrasound and its interaction with cells and tissues. More specifically, we address the acoustic settings and microbubble-related parameters (i.e., bubble size and physicochemistry of the bubble shell) that play a key role in microbubble-cell interactions and in the associated therapeutic outcome. Additionally, new techniques that may provide additional control over the treatment, such as monodisperse microbubble formulations, tunable ultrasound scanners, and cavitation detection techniques, are discussed. An in-depth understanding of the aspects presented in this work could eventually lead the way to more efficient and tailored microbubble-assisted ultrasound therapy in the future.
Collapse
Affiliation(s)
- Silke Roovers
- Laboratory of General Biochemistry and Physical Pharmacy, Ghent Research Group on Nanomedicine, Faculty of Pharmaceutical Sciences , Ghent University , Ottergemsesteenweg 460 , Ghent , Belgium
| | - Tim Segers
- Physics of Fluids Group, MESA+ Institute for Nanotechnology and Technical Medical (TechMed) Center , University of Twente , P.O. Box 217, 7500 AE Enschede , The Netherlands
| | - Guillaume Lajoinie
- Physics of Fluids Group, MESA+ Institute for Nanotechnology and Technical Medical (TechMed) Center , University of Twente , P.O. Box 217, 7500 AE Enschede , The Netherlands
| | - Joke Deprez
- Laboratory of General Biochemistry and Physical Pharmacy, Ghent Research Group on Nanomedicine, Faculty of Pharmaceutical Sciences , Ghent University , Ottergemsesteenweg 460 , Ghent , Belgium
| | - Michel Versluis
- Physics of Fluids Group, MESA+ Institute for Nanotechnology and Technical Medical (TechMed) Center , University of Twente , P.O. Box 217, 7500 AE Enschede , The Netherlands
| | - Stefaan C De Smedt
- Laboratory of General Biochemistry and Physical Pharmacy, Ghent Research Group on Nanomedicine, Faculty of Pharmaceutical Sciences , Ghent University , Ottergemsesteenweg 460 , Ghent , Belgium
| | - Ine Lentacker
- Laboratory of General Biochemistry and Physical Pharmacy, Ghent Research Group on Nanomedicine, Faculty of Pharmaceutical Sciences , Ghent University , Ottergemsesteenweg 460 , Ghent , Belgium
| |
Collapse
|
24
|
Koruk H, Choi JJ. Displacement of a bubble located at a fluid-viscoelastic medium interface. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 145:EL410. [PMID: 31153355 DOI: 10.1121/1.5108678] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/04/2019] [Accepted: 04/29/2019] [Indexed: 06/09/2023]
Abstract
A model for estimating the displacement of a bubble located at a fluid-viscoelastic medium interface in response to acoustic radiation force is presented by extending the model for a spherical object embedded in a bulk material. The effects of the stiffness and viscosity of the viscoelastic medium and the amplitude and duration of the excitation force on bubble displacement were investigated using the proposed model. The results show that bubble displacement has a nonlinear relationship with excitation duration and viscosity. The time at which the steady state is reached increases with increasing medium viscosity and decreasing medium stiffness.
Collapse
Affiliation(s)
- Hasan Koruk
- Mechanical Engineering Department, MEF University, Istanbul 34396,
| | - James J Choi
- Department of Bioengineering, Imperial College London, London SW7 2AZ, United
| |
Collapse
|
25
|
Wang T, Zhang FS, Ye HY, An LZ, Xiong LL, Huang XB, Xu QQ. Targeting silencing androgen receptor gene by shRNA with low-intensity focused ultrasonic irradiation inhibits growth of prostate cancer xenografts in nude mice. INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL PATHOLOGY 2019; 12:1295-1304. [PMID: 31933943 PMCID: PMC6947058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 01/18/2019] [Accepted: 02/21/2019] [Indexed: 06/10/2023]
Abstract
The androgen receptor (AR) plays a pivotal role in prostate cancer, making it a potential therapeutic target. Short-hairpin RNA (shRNA) inhibits gene expression and offers a novel strategy to eradicate disease. Ultrasound-mediated gene transfection is a promising gene delivery method. This study sought to determine whether targeting silencing androgen receptor gene by shRNA with low-intensity focused ultrasonic irradiation could be used as effective therapy for prostate cancers in vivo. A plasmid-based short-hairpin RNA combined with low-intensity focused ultrasonic irradiation approach was used to specifically knock down the expression of AR in prostate cancer 22RV1 cells in vivo. The growth of 22RV1 tumors that had been subcutaneously xenografted was evaluated and expression level of AR was determined by immunohistochemical staining. The proliferative index (PI) and the apoptotic index (AI) were respectively derived from the percentage of positive cells by Ki-67 immunohistochemical staining and TUNEL assay. The plasmid-based AR shRNA administrated intravenously significantly inhibited the tumor growth and AR expression. These inhibitory effects of AR shRNA were augmented when the region of tumor received low-intensity focused ultrasound irradiation. Immunohistochemical staining and TUNEL assay confirmed AR shRNA with low-intensity focused ultrasonic irradiation exhibited growth-inhibitory, antiproliferative, and apoptotic effects on prostate cancer xenografts. The authors showed for the first time that the knockdown of AR expression by plasmid-based AR shRNA with low-intensity focused ultrasonic irradiation significantly suppressed the tumor growth of prostate cancer in vivo.
Collapse
Affiliation(s)
- Tian Wang
- Urology and Lithotripsy Center, Peking University People's Hospital Beijing, China
| | - Feng-Shi Zhang
- Urology and Lithotripsy Center, Peking University People's Hospital Beijing, China
| | - Hai-Yun Ye
- Urology and Lithotripsy Center, Peking University People's Hospital Beijing, China
| | - Li-Zhe An
- Urology and Lithotripsy Center, Peking University People's Hospital Beijing, China
| | - Liu-Lin Xiong
- Urology and Lithotripsy Center, Peking University People's Hospital Beijing, China
| | - Xiao-Bo Huang
- Urology and Lithotripsy Center, Peking University People's Hospital Beijing, China
| | - Qing-Quan Xu
- Urology and Lithotripsy Center, Peking University People's Hospital Beijing, China
| |
Collapse
|
26
|
Abstract
Medical ultrasound technology is available, affordable, and non-invasive. It is used to detect, quantify, and heat tissue structures. This review article gives a concise overview of the types of behaviour that biological cells experience under the influence of ultrasound only, i.e., without the presence of microbubbles. The phenomena are discussed from a physics and engineering perspective. They include proliferation, translation, apoptosis, lysis, transient membrane permeation, and oscillation. The ultimate goal of cellular acoustics is the detection, quantification, manipulation and eradication of individual cells.
Collapse
|
27
|
Shao XH, Dong XQ, Kong DJ, Zhang LW, Wang LL, Wang SM. Contrast-Enhanced Ultrasonography in Sclerotherapy for Ovarian Endometrial Cyst. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:1828-1835. [PMID: 29730067 DOI: 10.1016/j.ultrasmedbio.2018.03.025] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2017] [Revised: 03/27/2018] [Accepted: 03/29/2018] [Indexed: 06/08/2023]
Abstract
We investigated contrast-enhanced ultrasonography (CEUS) characteristics related to the perfusion pattern and parameters of the time-intensity curve of ovarian endometrial cysts (OECs) pre- and post-sclerotherapy. Forty-three patients with one-sided, single, untreated OECs underwent CEUS pre- and post-sclerotherapy. OEC wall thickness was measured by 2-D ultrasonography and CEUS, and CEUS enhancement patterns and time-intensity curve parameters before and after sclerotherapy were compared. OEC wall thickness remained essentially unchanged post-sclerotherapy. Wall thickness was significantly larger on 2-D ultrasonography than on CEUS. The OEC wall exhibited rapid enhancement and slow clearance both pre- and post-sclerotherapy. Wash-in and wash-out times remained unchanged. The wall exhibited iso-enhancement pre-sclerotherapy, but low and partially uneven enhancement post-sclerotherapy. Post-treatment, time to peak was delayed, peak intensity was reduced and perfusion slope was decreased. The contrast agent arrival time and area under the curve remained similar. CEUS enhancement patterns and quantitative parameters were altered post-sclerotherapy; thus, treatments involving sclerosing agent retention can help to improve the efficacy of sclerotherapy for OEC.
Collapse
Affiliation(s)
- Xiao-Hui Shao
- Department of Ultrasonography, Fourth Hospital of Harbin Medical University, Harbin, China
| | - Xiao-Qiu Dong
- Department of Ultrasonography, Fourth Hospital of Harbin Medical University, Harbin, China.
| | - De-Jiao Kong
- Department of Ultrasonography, Fourth Hospital of Harbin Medical University, Harbin, China
| | - Li-Wei Zhang
- Department of Ultrasonography, Fourth Hospital of Harbin Medical University, Harbin, China
| | - Lu-Lu Wang
- Department of Ultrasonography, Fourth Hospital of Harbin Medical University, Harbin, China
| | - Si-Ming Wang
- Department of Ultrasonography, Fourth Hospital of Harbin Medical University, Harbin, China
| |
Collapse
|
28
|
Durot I, Wilson SR, Willmann JK. Contrast-enhanced ultrasound of malignant liver lesions. Abdom Radiol (NY) 2018; 43:819-847. [PMID: 29094174 DOI: 10.1007/s00261-017-1360-8] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Contrast-enhanced ultrasound (CEUS) is a safe, relatively inexpensive, and widely available imaging technique using dedicated imaging ultrasound sequences and FDA-approved contrast microbubbles that allow detection and characterization of malignant focal liver lesions with high diagnostic accuracy. CEUS provides dynamic real-time imaging with high spatial and temporal capability, allowing for unique contributions to the already established protocols for diagnosing focal liver lesions using CT and MR imaging. In patients with lesions indeterminate on CT and MRI, CEUS is a helpful problem-solving complementary tool that improves patient management. Furthermore, CEUS assists guidance of liver biopsies and local treatment. Variations of CEUS such as DCE-US and ultrasound molecular imaging are emerging for quantitative monitoring of treatment effects and possible earlier detection of cancer. In this review, basic principles of CEUS techniques and ultrasound contrast agents along with a description of the enhancement patterns of malignant liver lesions are summarized. Also, a discussion of the role of CEUS for treatment guidance and monitoring, intraoperative CEUS, and an outlook on emerging applications is provided.
Collapse
|
29
|
Sameera S, Aravind Kumar P, Nagasri M, Indeevar P, Raviraj K. ENAP vs LANAP: assessment of revascularization using ultrasound Doppler flowmetry-a split-mouth randomized controlled clinical trial. Lasers Med Sci 2018; 33:1181-1188. [PMID: 29392530 DOI: 10.1007/s10103-018-2451-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2017] [Accepted: 01/15/2018] [Indexed: 10/18/2022]
Abstract
Laser-assisted new attachment procedure (LANAP) is a new protocol that has been proposed for the treatment of periodontitis. However, there is little evidence regarding the rate of revascularization and the clinical efficacy of LANAP over conventional periodontal therapies. Hence, this study is done to evaluate and compare the clinical efficacy of LANAP vs Excisional new attachment procedure (ENAP) and also to assess the blood flow in both the techniques using ultrasound Doppler flowmetry. A split-mouth double-blinded controlled clinical trial was carried out in 15 subjects with chronic periodontitis. In every patient, 2 quadrants were treated with ENAP and the other 2 quadrants with LANAP. Clinical parameters like plaque index (PI), gingival index (GI), pocket depth (PD), clinical attachment level (CAL), and radiographic measurements (RBL) were recorded at baseline and 6, 9, and 12 months, postoperatively. Gingival blood flow assessment was done at baseline and on the ninth day postoperatively. Both the groups showed statistically significant reduction in all the clinical parameters when compared from baseline to subsequent follow-up visits. There was greater reduction in all the parameters in LANAP group than that of ENAP group. The rate of revascularization was higher in ENAP group than that of LANAP group when compared from baseline to the ninth day postoperatively. Although there is a delay in the rate of revascularization in the LANAP group, there was significant improvement in all the clinical and radiographic parameters than that of the ENAP group when compared from baseline to follow-up visits.
Collapse
Affiliation(s)
- Shaik Sameera
- Department of Periodontics and Implantology, St. Joseph Dental College, Eluru, India.
| | | | - Medandrao Nagasri
- Department of Periodontics and Implantology, St. Joseph Dental College, Eluru, India
| | - Pantareddy Indeevar
- Department of Periodontics and Implantology, St. Joseph Dental College, Eluru, India
| | - Kalapala Raviraj
- Department of Periodontics and Implantology, St. Joseph Dental College, Eluru, India
| |
Collapse
|
30
|
Sayadi LR, Banyard DA, Ziegler ME, Obagi Z, Prussak J, Klopfer MJ, Evans GR, Widgerow AD. Topical oxygen therapy & micro/nanobubbles: a new modality for tissue oxygen delivery. Int Wound J 2018; 15:363-374. [PMID: 29314626 DOI: 10.1111/iwj.12873] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2017] [Revised: 11/06/2017] [Accepted: 11/16/2017] [Indexed: 12/26/2022] Open
Abstract
Up to 15 billion dollars of US health care expenditure each year is consumed by treatment of poorly healing wounds whose etiologies are often associated with aberrancies in tissue oxygenation. To address this issue, several modes of tissue oxygen delivery systems exist, including Hyperbaric Oxygen Therapy (HBOT) and Topical Oxygen Therapy (TOT), but their efficacies have yet to be fully substantiated. Micro/nanobubbles (MNBs), which range anywhere from 100 μm to <1 μm in diameter and are relatively stable for hours, offer a new mode of oxygen delivery to wounds. The aim of this article is to systematically review literature examining the use of TOT for wound healing and use of MNBs for tissue oxygenation using the MEDLINE database. The search yielded 87 articles (12 MNB articles and 75 TOT articles), of which 52 met the inclusion criteria for this literature review (12 MNB articles and 40 TOT articles). Additionally, we present an analysis on the efficacy of our MNB generating technology and propose its use as a wound healing agent.
Collapse
Affiliation(s)
- Lohrasb R Sayadi
- Center for Tissue Engineering, Plastic Surgery Department, University of California, Irvine, California
| | - Derek A Banyard
- Center for Tissue Engineering, Plastic Surgery Department, University of California, Irvine, California
| | - Mary E Ziegler
- Center for Tissue Engineering, Plastic Surgery Department, University of California, Irvine, California
| | - Zaidal Obagi
- Center for Tissue Engineering, Plastic Surgery Department, University of California, Irvine, California
| | - Jordyne Prussak
- Center for Tissue Engineering, Plastic Surgery Department, University of California, Irvine, California
| | - Michael J Klopfer
- Biomedical Engineering Department, University of California, Irvine, California
| | - Gregory Rd Evans
- Center for Tissue Engineering, Plastic Surgery Department, University of California, Irvine, California
| | - Alan D Widgerow
- Center for Tissue Engineering, Plastic Surgery Department, University of California, Irvine, California
| |
Collapse
|
31
|
Малаханов В, Malakhanov V, Селиверстов П, Seliverstov P. RADIOLOGICAL DIAGNOSTICS OF BILE DUCTS CONSTRICTIVE LESIONS (REVIEW OF LITERATURE). ACTA BIOMEDICA SCIENTIFICA 2017. [DOI: 10.12737/article_5955e6b64836e8.79871884] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
|
32
|
Kim GW, Kang C, Oh YB, Ko MH, Seo JH, Lee D. Ultrasonographic Imaging and Anti-inflammatory Therapy of Muscle and Tendon Injuries Using Polymer Nanoparticles. Theranostics 2017; 7:2463-2476. [PMID: 28744328 PMCID: PMC5525750 DOI: 10.7150/thno.18922] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2016] [Accepted: 04/17/2017] [Indexed: 12/23/2022] Open
Abstract
Ultrasonography is a reliable diagnostic modality for muscle and tendon injuries, but it has been challenging to find right diagnosis of minor musculoskeletal injuries by conventional ultrasonographic imaging. A large amount of hydrogen peroxide (H2O2) are known to be generated during tissue damages such as mechanical injury and therefore H2O2 holds great potential as a diagnostic and therapeutic marker for mechanical injuries in the musculoskeletal system. We previously developed poly(vanillyl alcohol-co-oxalate) (PVAX), which rapidly scavenges H2O2 and exerts antioxidant and anti-inflammatory activity in H2O2-associated diseases. Based on the notion that PVAX nanoparticles generate CO2 bubbles through H2O2-triggered hydrolysis, we postulated that PVAX nanoparticles could serve as ultrasonographic contrast agents and therapeutic agents for musculoskeletal injuries associated with overproduction of H2O2. In the agarose gel phantom study, PVAX nanoparticles continuously generated CO2 bubbles to enhance ultrasonographic echogenicity significantly. Contusion injury significantly elevated the level of H2O2 in skeletal muscles and Achilles tendons. Upon intramuscular injection, PVAX nanoparticles significantly elevated the ultrasound contrast and suppressed inflammation and apoptosis in the contusion injury of musculoskeletal systems. We anticipate that PVAX nanoparticles hold great translational potential as theranostic agents for musculoskeletal injuries.
Collapse
Affiliation(s)
- Gi-Wook Kim
- Department of Physical Medicine and Rehabilitation, Chonbuk National University Medical School, Chonbuk, 561-756, Republic of Korea
- Research Institute of Clinical Medicine of Chonbuk National University- Biomedical Research Institute of Chonbuk National University Hospital, Chonbuk, 561-756, Republic of Korea
- Translational Research & Clinical Trial Center for Medical Device, Chonbuk National University Hospital, Chonbuk, 561-756, Republic of Korea
| | - Changsun Kang
- Department of BIN Convergence Technology, Chonbuk National University, Chonbuk, 561-756, Republic of Korea
| | - Young-Bin Oh
- Department of Physical Medicine and Rehabilitation, Chonbuk National University Medical School, Chonbuk, 561-756, Republic of Korea
- Research Institute of Clinical Medicine of Chonbuk National University- Biomedical Research Institute of Chonbuk National University Hospital, Chonbuk, 561-756, Republic of Korea
| | - Myoung-Hwan Ko
- Department of Physical Medicine and Rehabilitation, Chonbuk National University Medical School, Chonbuk, 561-756, Republic of Korea
- Research Institute of Clinical Medicine of Chonbuk National University- Biomedical Research Institute of Chonbuk National University Hospital, Chonbuk, 561-756, Republic of Korea
- Translational Research & Clinical Trial Center for Medical Device, Chonbuk National University Hospital, Chonbuk, 561-756, Republic of Korea
| | - Jeong-Hwan Seo
- Department of Physical Medicine and Rehabilitation, Chonbuk National University Medical School, Chonbuk, 561-756, Republic of Korea
- Research Institute of Clinical Medicine of Chonbuk National University- Biomedical Research Institute of Chonbuk National University Hospital, Chonbuk, 561-756, Republic of Korea
- Translational Research & Clinical Trial Center for Medical Device, Chonbuk National University Hospital, Chonbuk, 561-756, Republic of Korea
| | - Dongwon Lee
- Department of BIN Convergence Technology, Chonbuk National University, Chonbuk, 561-756, Republic of Korea
- Department of Polymer•Nano Science and Technology, Chonbuk National University, Chonbuk, 561-756, Republic of Korea
| |
Collapse
|
33
|
Ito T, Sugiura T, Okamura Y, Yamamoto Y, Ashida R, Aramaki T, Endo M, Uesaka K. The diagnostic advantage of EOB-MR imaging over CT in the detection of liver metastasis in patients with potentially resectable pancreatic cancer. Pancreatology 2017; 17:451-456. [PMID: 28298257 DOI: 10.1016/j.pan.2017.03.001] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/20/2016] [Revised: 02/12/2017] [Accepted: 03/05/2017] [Indexed: 12/11/2022]
Abstract
BACKGROUND Liver metastases (LMs) are sometimes diagnosed intraoperatively, even when multidetector-row computed tomography (MDCT) reveals no LM in the staging of pancreatic cancer (PC). Gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid-enhanced magnetic resonance imaging (EOB-MR imaging) may have a role to play in the detection of LM. METHODS The present study included a total of 201 patients who underwent an EOB-MR imaging examination before undergoing surgical resection for pancreatic cancer that was determined to be radiologically-resectable by MDCT. Intrahepatic lesions that were considered suspected to be liver metastases following an EOB-MR imaging examination were defined as possible lesions (PLs). All PLs were evaluated by a pathological examination or through close follow-up examinations. The diagnostic ability of EOB-MR imaging was assessed. The predictive factors for liver metastasis were evaluated. RESULTS Thirty-seven PLs were noted in 17 patients: 31 PLs were true LMs, and six were benign lesions (3 hemangiomas and 3 abscesses). Nine LMs were newly detected during surgery and were not detected by preoperative EOB-MR imaging. The diagnostic ability of EOB-MR imaging was as follows: sensitivity, 77.5%; specificity, 94.7%; positive predictive value, 83.8%; negative predictive value, 92.3%; and accuracy, 90.2%. A multivariate analysis revealed that the presence of PL on EOB-MR imaging was the only independent risk factor for intraoperative liver metastasis (P < 0.001). CONCLUSION EOB-MR imaging was useful in detecting tiny liver metastases from pancreatic cancer in cases that were determined to be radiologically resectable by MDCT.
Collapse
Affiliation(s)
- Takaaki Ito
- Division of Hepato-Biliary-Pancreatic Surgery, Shizuoka Cancer Center Hospital, Shizuoka, Japan.
| | - Teiichi Sugiura
- Division of Hepato-Biliary-Pancreatic Surgery, Shizuoka Cancer Center Hospital, Shizuoka, Japan
| | - Yukiyasu Okamura
- Division of Hepato-Biliary-Pancreatic Surgery, Shizuoka Cancer Center Hospital, Shizuoka, Japan
| | - Yusuke Yamamoto
- Division of Hepato-Biliary-Pancreatic Surgery, Shizuoka Cancer Center Hospital, Shizuoka, Japan
| | - Ryo Ashida
- Division of Hepato-Biliary-Pancreatic Surgery, Shizuoka Cancer Center Hospital, Shizuoka, Japan
| | - Takeshi Aramaki
- Division of Diagnostic Radiology, Shizuoka Cancer Center Hospital, Shizuoka, Japan
| | - Masahiro Endo
- Division of Diagnostic Radiology, Shizuoka Cancer Center Hospital, Shizuoka, Japan
| | - Katsuhiko Uesaka
- Division of Hepato-Biliary-Pancreatic Surgery, Shizuoka Cancer Center Hospital, Shizuoka, Japan
| |
Collapse
|
34
|
Sanginario A, Miccoli B, Demarchi D. Carbon Nanotubes as an Effective Opportunity for Cancer Diagnosis and Treatment. BIOSENSORS 2017; 7:E9. [PMID: 28212271 PMCID: PMC5371782 DOI: 10.3390/bios7010009] [Citation(s) in RCA: 80] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/23/2016] [Revised: 02/08/2017] [Accepted: 02/09/2017] [Indexed: 12/21/2022]
Abstract
Despite the current progresses of modern medicine, the resistance of malignant tumors to present medical treatments points to the necessity of developing new therapeutic approaches. In recent years, numerous studies have focused their attention on the promising use of nanomaterials, like iron oxide nanowires, zinc oxide or mesoporous silica nanoparticles, for cancer and metastasis treatment with the advantage of operating directly at the bio-molecular scale. Among them, carbon nanotubes emerged as valid candidates not only for drug delivery, but also as a valuable tool in cancer imaging and physical ablation. Nevertheless, deep investigations about carbon nanotubes' potential bio-compatibility and cytotoxicity limits should be also critically addressed. In the present review, after introducing carbon nanotubes and their promising advantages and drawbacks for fighting cancer, we want to focus on the numerous and different ways in which they can assist to reach this goal. Specifically, we report on how they can be used not only for drug delivery purposes, but also as a powerful ally to develop effective contrast agents for tumors' medical or photodynamic imaging, to perform direct physical ablation of metastasis, as well as gene therapy.
Collapse
Affiliation(s)
- Alessandro Sanginario
- Electronics Design Laboratory (EDL), Istituto Italiano di Tecnologia, Via Melen 83b, 16152 Genova (GE), Italy.
| | - Beatrice Miccoli
- Department of Electronics and Telecommunications, Politecnico di Torino, C.so Duca degli Abruzzi 24, 10129 Torino, Italy.
| | - Danilo Demarchi
- Department of Electronics and Telecommunications, Politecnico di Torino, C.so Duca degli Abruzzi 24, 10129 Torino, Italy.
| |
Collapse
|
35
|
Huang H, Lovell JF. Advanced Functional Nanomaterials for Theranostics. ADVANCED FUNCTIONAL MATERIALS 2017; 27:1603524. [PMID: 28824357 PMCID: PMC5560626 DOI: 10.1002/adfm.201603524] [Citation(s) in RCA: 138] [Impact Index Per Article: 17.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
Nanoscale materials have been explored extensively as agents for therapeutic and diagnostic (i.e. theranostic) applications. Research efforts have shifted from exploring new materials in vitro to designing materials that function in more relevant animal disease models, thereby increasing potential for clinical translation. Current interests include non-invasive imaging of diseases, biomarkers and targeted delivery of therapeutic drugs. Here, we discuss some general design considerations of advanced theranostic materials and challenges of their use, from both diagnostic and therapeutic perspectives. Common classes of nanoscale biomaterials, including magnetic nanoparticles, quantum dots, upconversion nanoparticles, mesoporous silica nanoparticles, carbon-based nanoparticles and organic dye-based nanoparticles, have demonstrated potential for both diagnosis and therapy. Variations such as size control and surface modifications can modulate biocompatibility and interactions with target tissues. The needs for improved disease detection and enhanced chemotherapeutic treatments, together with realistic considerations for clinically translatable nanomaterials will be key driving factors for theranostic agent research in the near future.
Collapse
Affiliation(s)
- Haoyuan Huang
- Department of Biomedical Engineering, University at Buffalo, State University of New York, Buffalo, New York, 14260, United States
| | - Jonathan F Lovell
- Department of Biomedical Engineering, University at Buffalo, State University of New York, Buffalo, New York, 14260, United States
| |
Collapse
|
36
|
Chakravarty R, Chakraborty S, Dash A. 64Cu2+ Ions as PET Probe: An Emerging Paradigm in Molecular Imaging of Cancer. Mol Pharm 2016; 13:3601-3612. [DOI: 10.1021/acs.molpharmaceut.6b00582] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Affiliation(s)
- Rubel Chakravarty
- Radiopharmaceuticals Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085, India
| | - Sudipta Chakraborty
- Radiopharmaceuticals Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085, India
| | - Ashutosh Dash
- Radiopharmaceuticals Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085, India
| |
Collapse
|
37
|
Van Cutsem E, Verheul HMW, Flamen P, Rougier P, Beets-Tan R, Glynne-Jones R, Seufferlein T. Imaging in Colorectal Cancer: Progress and Challenges for the Clinicians. Cancers (Basel) 2016; 8:cancers8090081. [PMID: 27589804 PMCID: PMC5040983 DOI: 10.3390/cancers8090081] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2016] [Revised: 08/22/2016] [Accepted: 08/24/2016] [Indexed: 01/05/2023] Open
Abstract
The use of imaging in colorectal cancer (CRC) has significantly evolved over the last twenty years, establishing important roles in surveillance, diagnosis, staging, treatment selection and follow up. The range of modalities has broadened with the development of novel tracer and contrast agents, and the fusion of technologies such as positron emission tomography (PET) and computed tomography (CT). Traditionally, the most widely used modality for assessing treatment response in metastasised colon and rectal tumours is CT, combined with use of the RECIST guidelines. However, a growing body of evidence suggests that tumour size does not always adequately correlate with clinical outcomes. Magnetic resonance imaging (MRI) is a more versatile technique and dynamic contrast-enhanced (DCE)-MRI and diffusion-weighted (DW)-MRI may be used to evaluate biological and functional effects of treatment. Integrated fluorodeoxyglucose (FDG)-PET/CT combines metabolic and anatomical imaging to improve sensitivity and specificity of tumour detection, and a number of studies have demonstrated improved diagnostic accuracy of this modality in a variety of tumour types, including CRC. These developments have enabled the progression of treatment strategies in rectal cancer and improved the detection of hepatic metastatic disease, yet are not without their limitations. These include technical, economical and logistical challenges, along with a lack of robust evidence for standardisation and formal guidance. In order to successfully apply these novel imaging techniques and utilise their benefit to provide truly personalised cancer care, advances need to be clinically realised in a routine and robust manner.
Collapse
Affiliation(s)
- Eric Van Cutsem
- Department of Gastroenterology/Digestive Oncology, University Hospitals Gasthuisberg Leuven and KU Leuven, 3000 Leuven, Belgium.
| | - Henk M W Verheul
- Division of Medical Oncology, VU University Medical Centre, 1081 HV Amsterdam, The Netherlands.
| | - Patrik Flamen
- Nuclear Medicine Imaging and Therapy Department, Institut Jules Bordet, Université Libre de Bruxelles, 1000 Brussels, Belgium.
| | - Philippe Rougier
- Gastroenterology and Digestive Oncology Department, European Hospital, Georges Pompidou, 75015 Paris, France.
| | - Regina Beets-Tan
- Department of Radiology, The Netherlands Cancer Institute, 1066 CX Amsterdam, The Netherlands.
| | - Rob Glynne-Jones
- Department of Medical Oncology, Mount Vernon Centre for Cancer Treatment, HA6 2RN Middlesex, UK.
| | - Thomas Seufferlein
- Clinic of Internal Medicine I, University Hospital Ulm, 89081 Ulm, Germany.
| |
Collapse
|
38
|
Yang C, Lee DH, Mangraviti A, Su L, Zhang K, Zhang Y, Zhang B, Li W, Tyler B, Wong J, Wang KKH, Velarde E, Zhou J, Ding K. Quantitative correlational study of microbubble-enhanced ultrasound imaging and magnetic resonance imaging of glioma and early response to radiotherapy in a rat model. Med Phys 2016; 42:4762-72. [PMID: 26233204 DOI: 10.1118/1.4926550] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
PURPOSE Radiotherapy remains a major treatment method for malignant tumors. Magnetic resonance imaging (MRI) is the standard modality for assessing glioma treatment response in the clinic. Compared to MRI, ultrasound imaging is low-cost and portable and can be used during intraoperative procedures. The purpose of this study was to quantitatively compare contrast-enhanced ultrasound (CEUS) imaging and MRI of irradiated gliomas in rats and to determine which quantitative ultrasound imaging parameters can be used for the assessment of early response to radiation in glioma. METHODS Thirteen nude rats with U87 glioma were used. A small thinned skull window preparation was performed to facilitate ultrasound imaging and mimic intraoperative procedures. Both CEUS and MRI with structural, functional, and molecular imaging parameters were performed at preradiation and at 1 day and 4 days postradiation. Statistical analysis was performed to determine the correlations between MRI and CEUS parameters and the changes between pre- and postradiation imaging. RESULTS Area under the curve (AUC) in CEUS showed significant difference between preradiation and 4 days postradiation, along with four MRI parameters, T2, apparent diffusion coefficient, cerebral blood flow, and amide proton transfer-weighted (APTw) (all p < 0.05). The APTw signal was correlated with three CEUS parameters, rise time (r = - 0.527, p < 0.05), time to peak (r = - 0.501, p < 0.05), and perfusion index (r = 458, p < 0.05). Cerebral blood flow was correlated with rise time (r = - 0.589, p < 0.01) and time to peak (r = - 0.543, p < 0.05). CONCLUSIONS MRI can be used for the assessment of radiotherapy treatment response and CEUS with AUC as a new technique and can also be one of the assessment methods for early response to radiation in glioma.
Collapse
Affiliation(s)
- Chen Yang
- Department of Ultrasound, Zhejiang Cancer Hospital, Hangzhou, Zhejiang 310022, China
| | - Dong-Hoon Lee
- Division of MR Research, Department of Radiology, Johns Hopkins University, School of Medicine, Baltimore, Maryland 21287
| | - Antonella Mangraviti
- Department of Neurosurgery, Johns Hopkins University, School of Medicine, Baltimore, Maryland 21287
| | - Lin Su
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, School of Medicine, Baltimore, Maryland 21231
| | - Kai Zhang
- Division of MR Research, Department of Radiology, Johns Hopkins University, School of Medicine, Baltimore, Maryland 21287
| | - Yin Zhang
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, School of Medicine, Baltimore, Maryland 21231
| | - Bin Zhang
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, School of Medicine, Baltimore, Maryland 21231
| | - Wenxiao Li
- Division of MR Research, Department of Radiology, Johns Hopkins University, School of Medicine, Baltimore, Maryland 21287
| | - Betty Tyler
- Department of Neurosurgery, Johns Hopkins University, School of Medicine, Baltimore, Maryland 21287
| | - John Wong
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, School of Medicine, Baltimore, Maryland 21231
| | - Ken Kang-Hsin Wang
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, School of Medicine, Baltimore, Maryland 21231
| | - Esteban Velarde
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, School of Medicine, Baltimore, Maryland 21231
| | - Jinyuan Zhou
- Division of MR Research, Department of Radiology, Johns Hopkins University, School of Medicine, Baltimore, Maryland 21287
| | - Kai Ding
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, School of Medicine, Baltimore, Maryland 21231
| |
Collapse
|
39
|
Conversano F, Pisani P, Casciaro E, Di Paola M, Leporatti S, Franchini R, Quarta A, Gigli G, Casciaro S. Automatic Echographic Detection of Halloysite Clay Nanotubes in a Low Concentration Range. NANOMATERIALS (BASEL, SWITZERLAND) 2016; 6:E66. [PMID: 28335194 PMCID: PMC5302578 DOI: 10.3390/nano6040066] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/06/2016] [Revised: 04/01/2016] [Accepted: 04/05/2016] [Indexed: 12/29/2022]
Abstract
Aim of this work was to investigate the automatic echographic detection of an experimental drug delivery agent, halloysite clay nanotubes (HNTs), by employing an innovative method based on advanced spectral analysis of the corresponding "raw" radiofrequency backscatter signals. Different HNT concentrations in a low range (5.5-66 × 1010 part/mL, equivalent to 0.25-3.00 mg/mL) were dispersed in custom-designed tissue-mimicking phantoms and imaged through a clinically-available echographic device at a conventional ultrasound diagnostic frequency (10 MHz). The most effective response (sensitivity = 60%, specificity = 95%), was found at a concentration of 33 × 1010 part/mL (1.5 mg/mL), representing a kind of best compromise between the need of enough particles to introduce detectable spectral modifications in the backscattered signal and the necessity to avoid the losses of spectral peculiarity associated to higher HNT concentrations. Based on theoretical considerations and quantitative comparisons with literature-available results, this concentration could also represent an optimal concentration level for the automatic echographic detection of different solid nanoparticles when employing a similar ultrasound frequency. Future dedicated studies will assess the actual clinical usefulness of the proposed approach and the potential of HNTs for effective theranostic applications.
Collapse
Affiliation(s)
- Francesco Conversano
- National Research Council, Institute of Clinical Physiology, Lecce 73100, Italy.
| | - Paola Pisani
- National Research Council, Institute of Clinical Physiology, Lecce 73100, Italy.
| | - Ernesto Casciaro
- National Research Council, Institute of Clinical Physiology, Lecce 73100, Italy.
| | - Marco Di Paola
- National Research Council, Institute of Clinical Physiology, Lecce 73100, Italy.
| | - Stefano Leporatti
- National Research Council, Institute of Nanotechnology, Lecce 73100, Italy.
| | - Roberto Franchini
- National Research Council, Institute of Clinical Physiology, Lecce 73100, Italy.
| | - Alessandra Quarta
- National Research Council, Institute of Nanotechnology, Lecce 73100, Italy.
| | - Giuseppe Gigli
- National Research Council, Institute of Nanotechnology, Lecce 73100, Italy.
| | - Sergio Casciaro
- National Research Council, Institute of Clinical Physiology, Lecce 73100, Italy.
| |
Collapse
|
40
|
Feasibility of A-mode ultrasound attenuation as a monitoring method of local hyperthermia treatment. Med Biol Eng Comput 2016; 54:967-81. [DOI: 10.1007/s11517-016-1480-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2014] [Accepted: 02/28/2016] [Indexed: 01/19/2023]
|
41
|
Hua X, Ding J, Li R, Zhang Y, Huang Z, Guo Y, Chen Q. Anti-tumor effect of ultrasound-induced Nordy-loaded microbubbles destruction. J Drug Target 2016; 24:703-8. [PMID: 26811100 DOI: 10.3109/1061186x.2016.1144058] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
BACKGROUND Synthesized dl-Nordihydroguaiaretic acid (dl-NGDA or "Nordy") can inhibit the growth of malignant human tumors, especially the tumor angiogenesis. However, its liposoluble nature limits its in vivo efficacy in the hydrosoluble circulation of human. PURPOSE We tried to use the ultrasonic microbubble as the carrier and the ultrasound-induced destruction for the targeted release of Nordy and evaluate its in vitro and in vivo anti-tumor effect. METHODS Nordy-loaded lipid microbubbles were prepared by mechanical vibration. Effects of ultrasound-induced Nordy-loaded microbubbles destruction on proliferation of human umbilical vein endothelial cells (HUVECs), tumor derived endothelial cells (Td-ECs), and rabbit transplanted VX2 tumor models were evaluated. RESULTS The ultrasound-induced Nordy-loaded microbubbles destruction inhibited the proliferations of HUVECs and Td-ECs in vitro, and inhibited the tumor growth and the microvasculature in vivo. Its efficacy was higher than those of Nordy used only and Nordy with ultrasound exposure. CONCLUSION Ultrasonic microbubbles can be used as the carrier of Nordy and achieve its targeted release with improved anti-tumor efficacy in the condition of ultrasound-induced microbubbles destruction.
Collapse
Affiliation(s)
- Xing Hua
- a Third Military Medical University, Southwest Hospital , Chongqing , China
| | - Jun Ding
- a Third Military Medical University, Southwest Hospital , Chongqing , China
| | - Rui Li
- a Third Military Medical University, Southwest Hospital , Chongqing , China
| | - Ying Zhang
- a Third Military Medical University, Southwest Hospital , Chongqing , China
| | - Zejun Huang
- a Third Military Medical University, Southwest Hospital , Chongqing , China
| | - Yanli Guo
- a Third Military Medical University, Southwest Hospital , Chongqing , China
| | - Qinghai Chen
- a Third Military Medical University, Southwest Hospital , Chongqing , China
| |
Collapse
|
42
|
Dolci S, Domenici V, Vidili G, Orecchioni M, Bandiera P, Madeddu R, Farace C, Peana M, Tiné MR, Manetti R, Sgarrella F, Delogu LG. Immune compatible cystine-functionalized superparamagnetic iron oxide nanoparticles as vascular contrast agents in ultrasonography. RSC Adv 2016. [DOI: 10.1039/c5ra19652c] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
Superparamagnetic iron oxide nanoparticles (SPIONs) have been investigated for biomedical applications.
Collapse
Affiliation(s)
- Sara Dolci
- Department of Chemistry and Industrial Chemistry
- University of Pisa
- 56124 Pisa
- Italy
| | - Valentina Domenici
- Department of Chemistry and Industrial Chemistry
- University of Pisa
- 56124 Pisa
- Italy
| | - Gianpaolo Vidili
- Department of Clinical and Experimental Medicine
- University of Sassari
- 07100 Sassari
- Italy
| | - Marco Orecchioni
- Department of Chemistry and Pharmacy
- University of Sassari
- 07100 Sassari
- Italy
| | - Pasquale Bandiera
- Department of Biomedical Sciences
- University of Sassari
- 07100 Sassari
- Italy
| | - Roberto Madeddu
- Department of Biomedical Sciences
- University of Sassari
- 07100 Sassari
- Italy
| | - Cristiano Farace
- Department of Biomedical Sciences
- University of Sassari
- 07100 Sassari
- Italy
| | - Massimiliano Peana
- Department of Chemistry and Pharmacy
- University of Sassari
- 07100 Sassari
- Italy
| | - Maria Rosaria Tiné
- Department of Chemistry and Industrial Chemistry
- University of Pisa
- 56124 Pisa
- Italy
| | - Roberto Manetti
- Department of Clinical and Experimental Medicine
- University of Sassari
- 07100 Sassari
- Italy
| | | | - Lucia Gemma Delogu
- Department of Chemistry and Pharmacy
- University of Sassari
- 07100 Sassari
- Italy
| |
Collapse
|
43
|
Saftoiu A, Vilmann P, Bhutani MS. The role of contrast-enhanced endoscopic ultrasound in pancreatic adenocarcinoma. Endosc Ultrasound 2016; 5:368-372. [PMID: 28000627 PMCID: PMC5206824 DOI: 10.4103/2303-9027.190932] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
Contrast-enhanced endoscopic ultrasound (CE-EUS) allows characterization, differentiation, and staging of focal pancreatic masses. The method has a high sensitivity and specificity for the diagnosis of pancreatic adenocarcinoma which is visualized as hypo-enhanced as compared to the rest of the parenchyma while chronic pancreatitis and neuroendocrine tumors are generally either iso-enhanced or hyper-enhanced. The development of contrast-enhanced low mechanical index harmonic imaging techniques used in real time during endoscopic ultrasound (EUS) allowed perfusion imaging and the quantification of intensity of the contrast signal through time-intensity curve analysis. Thus, contrast harmonic imaging-EUS has been used to differentiate pancreatic adenocarcinoma based on lower values of the peak enhancement. Future applications of CE-EUS in pancreatic adenocarcinoma include not only use of targeted contrast agents for early detection, tridimensional and fusion techniques for enhanced staging and resectability assessment but also novel applications of perfusion imaging for monitoring ablative therapy, improved local detection through EUS-guided sampling of portal vein flow or enhanced drug delivery through sonoporation and ultrasound-induced release of the drugs locally.
Collapse
Affiliation(s)
- Adrian Saftoiu
- Research Center of Gastroenterology and Hepatology Craiova, University of Medicine and Pharmacy Craiova, Craiova, Romania; Division of Endoscopy, Gastro Unit, Copenhagen University Hospital Herlev, Herlev, Denmark
| | - Peter Vilmann
- Division of Endoscopy, Gastro Unit, Copenhagen University Hospital Herlev, Herlev, Denmark
| | - Manoop S Bhutani
- Department of Gastroenterology, Hepatology and Nutrition, MD Anderson Cancer Center, Houston, Texas, USA
| |
Collapse
|
44
|
Sun B, Lang L, Zhu X, Jiang F, Hong Y, He L. Accuracy of contrast-enhanced ultrasound in the identification of thyroid nodules: a meta-analysis. Int J Clin Exp Med 2015; 8:12882-12889. [PMID: 26550204 PMCID: PMC4612889] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2015] [Accepted: 06/24/2015] [Indexed: 06/05/2023]
Abstract
This meta-analysis aimed to identify the accuracy of contrast-enhanced ultrasonography (CEUS) on the diagnosis of thyroid nodules. PubMed, Chinese Biomedical Medical databases (CNKI), Wan Fang (Chinese), and EBSCO database were searched from inception through April 15, 2015 without language and geographic restrictions. MetaDisc version 1.4 software was applied for this meta-analysis. We calculated the summary statistics for sensitivity (Sen), specificity (Spe), positive and negative likelihood ratio (LR+/LR-), diagnostic odds ratio (DOR), and receiver operating characteristic (SROC) curve. Twenty-five eligible studies were included in this meta-analysis. A total of 424 in 1154 nodules is malignant thyroid tumors. After all thyroid lesions were histologically confirmed by CEUS, the pooled Sen was 0.88 (95% confidence interval [CI] 0.85-0.91); the pooled Spe was 0.90 (95% CI 0.88-0.92). The pooled positive LR+ was 8.69(95% CI 5.78-13.09); the pooled negative LR- was 0.15 (95% CI 0.12-0.19). The pooled DOR of CEUS in the diagnosis of thyroid nodules was 63.18 (95% CI 37.82-105.53). The area under the SROC curve was 0.946 (standard error [SE] = 0.010). Our meta-analysis indicates that CEUS may have high accuracy in diagnosis the difference between benign and malignant thyroid nodules. US is a traditional tool in the diagnosis thyroid nodules. However, with the development of science and technology, the emerging of CEUS significantly improve accuracy in the diagnosis thyroid nodules.
Collapse
Affiliation(s)
- Biyun Sun
- Department of Ultrasound, The First Affiliated Hospital of Wannan Medical CollegeWuhu 241002, Anhui, China
| | - Lin Lang
- School of Clinic Medical, Wannan Medical CollegeWuhu 241002, Anhui, China
| | - Xiangming Zhu
- Department of Ultrasound, The First Affiliated Hospital of Wannan Medical CollegeWuhu 241002, Anhui, China
| | - Feng Jiang
- Department of Ultrasound, The First Affiliated Hospital of Wannan Medical CollegeWuhu 241002, Anhui, China
| | - Yun Hong
- Department of Ultrasound, The First Affiliated Hospital of Wannan Medical CollegeWuhu 241002, Anhui, China
| | - Lianping He
- School of Public Health, Wannan Medical CollegeWuhu 241002, Anhui, China
| |
Collapse
|
45
|
Zeisbrich M, Kihm LP, Drüschler F, Zeier M, Schwenger V. When is contrast-enhanced sonography preferable over conventional ultrasound combined with Doppler imaging in renal transplantation? Clin Kidney J 2015; 8:606-14. [PMID: 26413289 PMCID: PMC4581388 DOI: 10.1093/ckj/sfv070] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2014] [Accepted: 07/10/2015] [Indexed: 12/18/2022] Open
Abstract
Conventional ultrasound in combination with colour Doppler imaging is still the standard diagnostic procedure for patients after renal transplantation. However, while conventional ultrasound in combination with Doppler imaging can diagnose renal artery stenosis and vein thrombosis, it is not possible to display subtle microvascular tissue perfusion, which is crucial for the evaluation of acute and chronic allograft dysfunctions. In contrast, real-time contrast-enhanced sonography (CES) uses gas-filled microbubbles not only to visualize but also to quantify renal blood flow and perfusion even in the small renal arterioles and capillaries. It is an easy to perform and non-invasive imaging technique that augments diagnostic capabilities in patients after renal transplantation. Specifically in the postoperative setting, CES has been shown to be superior to conventional ultrasound in combination with Doppler imaging in uncovering even subtle microvascular disturbances in the allograft perfusion. In addition, quantitative perfusion parameters derived from CES show predictive capability regarding long-term kidney function.
Collapse
Affiliation(s)
- Markus Zeisbrich
- Department of Nephrology , University Hospital , Heidelberg , Germany
| | - Lars P Kihm
- Department of Nephrology , University Hospital , Heidelberg , Germany
| | - Felix Drüschler
- Department of Nephrology , University Hospital , Heidelberg , Germany
| | - Martin Zeier
- Department of Nephrology , University Hospital , Heidelberg , Germany
| | - Vedat Schwenger
- Department of Nephrology , University Hospital , Heidelberg , Germany
| |
Collapse
|
46
|
Schäfer S, Nylund K, Sævik F, Engjom T, Mézl M, Jiřík R, Dimcevski G, Gilja OH, Tönnies K. Semi-automatic motion compensation of contrast-enhanced ultrasound images from abdominal organs for perfusion analysis. Comput Biol Med 2015; 63:229-37. [DOI: 10.1016/j.compbiomed.2014.09.014] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2014] [Revised: 09/29/2014] [Accepted: 09/30/2014] [Indexed: 02/07/2023]
|
47
|
Abstract
Ultrasonography (US) is a safe and available real-time, high-resolution imaging method, which during the last decades has been increasingly integrated as a clinical tool in gastroenterology. New US applications have emerged with enforced data software and new technical solutions, including strain evaluation, three-dimensional imaging and use of ultrasound contrast agents. Specific gastroenterologic applications have been developed by combining US with other diagnostic or therapeutic methods, such as endoscopy, manometry, puncture needles, diathermy and stents. US provides detailed structural information about visceral organs without hazard to the patients and can play an important clinical role by reducing the need for invasive procedures. This paper presents different aspects of US in gastroenterology, with a special emphasis on the contribution from Nordic scientists in developing clinical applications.
Collapse
Affiliation(s)
- Svein Ødegaard
- Department of Medicine, National Centre for Ultrasound in Gastroenterology, Haukeland University Hospital and Department of Clinical Medicine, University of Bergen , Bergen , Norway
| | | | | | | |
Collapse
|
48
|
Arteaga-Marrero N, Rygh CB, Mainou-Gomez JF, Nylund K, Roehrich D, Heggdal J, Matulaniec P, Gilja OH, Reed RK, Svensson L, Lutay N, Olsen DR. Multimodal approach to assess tumour vasculature and potential treatment effect with DCE-US and DCE-MRI quantification in CWR22 prostate tumour xenografts. CONTRAST MEDIA & MOLECULAR IMAGING 2015; 10:428-37. [PMID: 26010530 DOI: 10.1002/cmmi.1645] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2014] [Revised: 03/16/2015] [Accepted: 04/04/2015] [Indexed: 01/01/2023]
Abstract
The aim of this study was to compare intratumoural heterogeneity and longitudinal changes assessed by dynamic contrast-enhanced ultrasound (DCE-US) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in prostate tumour xenografts. In vivo DCE-US and DCE-MRI were obtained 24 h pre- (day 0) and post- (day 2) radiation treatment with a single dose of 7.5 Gy. Characterization of the tumour vasculature was determined by Brix pharmacokinetic analysis of the time-intensity curves. Histogram analysis of voxels showed significant changes (p < 0.001) from day 0 to day 2 in both modalities for kep , the exchange rate constant from the extracellular extravascular space to the plasma, and kel , the elimination rate constant of the contrast. In addition, kep and kel values from DCE-US were significantly higher than those derived from DCE-MRI at day 0 (p < 0.0001) for both groups. At day 2, kel followed the same tendency for both groups, whereas kep showed this tendency only for the treated group in intermediate-enhancement regions. Regarding kep median values, longitudinal changes were not found for any modality. However, at day 2, kep linked to DCE-US was correlated to MVD in high-enhancement areas for the treated group (p = 0.05). In contrast, correlation to necrosis was detected for the control group in intermediate-enhancement areas (p < 0.1). Intratumoural heterogeneity and longitudinal changes in tumour vasculature were assessed for both modalities. Microvascular parameters derived from DCE-US seem to provide reliable biomarkers during radiotherapy as validated by histology. Furthermore, DCE-US could be a stand-alone or a complementary technique.
Collapse
Affiliation(s)
- N Arteaga-Marrero
- Department of Physics and Technology, University of Bergen, Bergen, Norway
| | - C B Rygh
- Department of Biomedicine, University of Bergen, Bergen, Norway
| | - J F Mainou-Gomez
- Department of Clinical Medicine, University of Bergen, Bergen, Norway
| | - K Nylund
- National Centre for Ultrasound in Gastroenterology, Haukeland University Hospital, Bergen, Norway
| | - D Roehrich
- Department of Physics and Technology, University of Bergen, Bergen, Norway
| | - J Heggdal
- Department of Oncology and Medical Physics, Haukeland University Hospital, Bergen, Norway
| | - P Matulaniec
- Department of Physics and Technology, University of Bergen, Bergen, Norway
| | - O H Gilja
- Department of Clinical Medicine, University of Bergen, Bergen, Norway.,National Centre for Ultrasound in Gastroenterology, Haukeland University Hospital, Bergen, Norway
| | - R K Reed
- Department of Biomedicine, University of Bergen, Bergen, Norway.,Centre for Cancer Biomarkers (CCBIO), University of Bergen, Norway
| | - L Svensson
- Section of Immunology, Department of Experimental Medical Science, Lund University, Lund, Sweden
| | - N Lutay
- Division of Dermatology and Venereology, Department of Clinical Sciences, Lund University, Lund, Sweden
| | - D R Olsen
- Department of Physics and Technology, University of Bergen, Bergen, Norway
| |
Collapse
|
49
|
Owen J, Grove P, Rademeyer P, Stride E. The influence of blood on targeted microbubbles. J R Soc Interface 2015; 11:20140622. [PMID: 25253034 DOI: 10.1098/rsif.2014.0622] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023] Open
Abstract
The ability to successfully target the delivery of drugs and other therapeutic molecules has been a key goal of biomedical research for many decades. Despite highly promising in vitro results, however, successful translation of targeted drug delivery into clinical use has been extremely limited. This study investigates the significance of the characteristics of whole blood, which are rarely accounted for in vitro assays, as a possible explanation for the poor correlation between in vitro and in vivo experiments. It is shown using two separate model systems employing either biochemical or magnetic targeting that blood causes a substantial reduction in targeting efficiency relative to saline under the same flow conditions. This finding has important implications for the design of targeted drug delivery systems and the assays used in their development.
Collapse
Affiliation(s)
- Joshua Owen
- Institute of Biomedical Engineering, University of Oxford, Old Road Campus Research Building, Oxford OX3 7DQ, UK
| | - Philip Grove
- Institute of Biomedical Engineering, University of Oxford, Old Road Campus Research Building, Oxford OX3 7DQ, UK
| | - Paul Rademeyer
- Institute of Biomedical Engineering, University of Oxford, Old Road Campus Research Building, Oxford OX3 7DQ, UK
| | - Eleanor Stride
- Institute of Biomedical Engineering, University of Oxford, Old Road Campus Research Building, Oxford OX3 7DQ, UK
| |
Collapse
|
50
|
Dubory A, Laemmel E, Badner A, Duranteau J, Vicaut E, Court C, Soubeyrand M. Contrast enhanced ultrasound imaging for assessment of spinal cord blood flow in experimental spinal cord injury. J Vis Exp 2015:e52536. [PMID: 25993259 DOI: 10.3791/52536] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022] Open
Abstract
Reduced spinal cord blood flow (SCBF) (i.e., ischemia) plays a key role in traumatic spinal cord injury (SCI) pathophysiology and is accordingly an important target for neuroprotective therapies. Although several techniques have been described to assess SCBF, they all have significant limitations. To overcome the latter, we propose the use of real-time contrast enhanced ultrasound imaging (CEU). Here we describe the application of this technique in a rat contusion model of SCI. A jugular catheter is first implanted for the repeated injection of contrast agent, a sodium chloride solution of sulphur hexafluoride encapsulated microbubbles. The spine is then stabilized with a custom-made 3D-frame and the spinal cord dura mater is exposed by a laminectomy at ThIX-ThXII. The ultrasound probe is then positioned at the posterior aspect of the dura mater (coated with ultrasound gel). To assess baseline SCBF, a single intravenous injection (400 µl) of contrast agent is applied to record its passage through the intact spinal cord microvasculature. A weight-drop device is subsequently used to generate a reproducible experimental contusion model of SCI. Contrast agent is re-injected 15 min following the injury to assess post-SCI SCBF changes. CEU allows for real time and in-vivo assessment of SCBF changes following SCI. In the uninjured animal, ultrasound imaging showed uneven blood flow along the intact spinal cord. Furthermore, 15 min post-SCI, there was critical ischemia at the level of the epicenter while SCBF remained preserved in the more remote intact areas. In the regions adjacent to the epicenter (both rostral and caudal), SCBF was significantly reduced. This corresponds to the previously described "ischemic penumbra zone". This tool is of major interest for assessing the effects of therapies aimed at limiting ischemia and the resulting tissue necrosis subsequent to SCI.
Collapse
Affiliation(s)
- Arnaud Dubory
- Laboratoire d'étude de la microcirculation, Faculté de Médecine Paris Diderot Paris VII, U942; Department of orthopaedic surgery, Bicetre Universitary Hospital, Public Assistance of Paris Hospital
| | - Elisabeth Laemmel
- Laboratoire d'étude de la microcirculation, Faculté de Médecine Paris Diderot Paris VII, U942
| | - Anna Badner
- Institute of Medical Science, Faculty of Medicine, University of Toronto
| | - Jacques Duranteau
- Laboratoire d'étude de la microcirculation, Faculté de Médecine Paris Diderot Paris VII, U942; Department of Intensive care and Anesthesiology, Bicetre Universitary Hospital, Public Assistance of Paris Hospital
| | - Eric Vicaut
- Laboratoire d'étude de la microcirculation, Faculté de Médecine Paris Diderot Paris VII, U942
| | - Charles Court
- Department of orthopaedic surgery, Bicetre Universitary Hospital, Public Assistance of Paris Hospital
| | - Marc Soubeyrand
- Laboratoire d'étude de la microcirculation, Faculté de Médecine Paris Diderot Paris VII, U942; Department of orthopaedic surgery, Bicetre Universitary Hospital, Public Assistance of Paris Hospital;
| |
Collapse
|