Liu YJ, Tsai TS, Li YH, Peng JH, Chang HC, Peng HH, Lee YC, Lee TY, Liou CH, Lin TF, Chew FY, Chou RH, Juan CJ. Understanding ADC variation by fat content effect using a dual-function MRI phantom. Eur Radiol Exp 2024; 8:19. [PMID: 38347188 PMCID: PMC10861416 DOI: 10.1186/s41747-023-00414-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Accepted: 11/14/2023] [Indexed: 02/15/2024] Open
Abstract
BACKGROUND A dual-function phantom designed to quantify the apparent diffusion coefficient (ADC) in different fat contents (FCs) and glass bead densities (GBDs) to simulate the human tissues has not been documented yet. We propose a dual-function phantom to quantify the FC and to measure the ADC at different FCs and different GBDs. METHODS A fat-containing diffusion phantom comprised by 30 glass-bead-containing fat-water emulsions consisting of six different FCs (0, 10, 20, 30, 40, and 50%) multiplied by five different GBDs (0, 0.1, 0.25, 0.5, and 1.0 g/50 mL). The FC and ADC were measured by the "iterative decomposition of water and fat with echo asymmetry and least squares estimation-IQ," IDEAL-IQ, and single-shot echo-planar diffusion-weighted imaging, SS-EP-DWI, sequences, respectively. Linear regression analysis was used to evaluate the relationship among the fat fraction (FF) measured by IDEAL-IQ, GBD, and ADC. RESULTS The ADC was significantly, negatively, and linearly associated with the FF (the linear slope ranged from -0.005 to -0.017, R2 = 0.925 to 0.986, all p < 0.001). The slope of the linear relationship between the ADC and the FF, however, varied among different GBDs (the higher the GBD, the lower the slope). ADCs among emulsions across different GBDs and FFs were overlapped. Emulsions with low GBDs plus high FFs shared a same lower ADC range with those with median or high GBDs plus median or lower FFs. CONCLUSIONS A novel dual-function phantom simulating the human tissues allowed to quantify the influence of FC and GBD on ADC. RELEVANCE STATEMENT The study developed an innovative dual-function MRI phantom to explore the impact of FC on ADC variation that can affect clinical results. The results revealed the superimposed effect on FF and GBD density on ADC measurements. KEY POINTS • A dual-function phantom made of glass bead density (GBD) and fat fraction (FF) emulsion has been developed. • Apparent diffusion coefficient (ADC) values are determined by GBD and FF. • The dual-function phantom showed the mutual ADC addition between FF and GBD.
Collapse
Affiliation(s)
- Yi-Jui Liu
- Department of Automatic Control Engineering, Feng Chia University, Taichung, Taiwan, Republic of China
| | - Tung-Sheng Tsai
- Ph.D. Program in Electrical and Communication Engineering, Feng Chia University, Taichung, Taiwan, Republic of China
| | - Ya-Hui Li
- Department of Medical Imaging, China Medical University Hsinchu Hospital, 199, Sec. 1, Xinglong Rd., Zhubei City, Hsinchu County, 302, Taiwan, Republic of China
| | - Jo-Hua Peng
- Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan, Republic of China
| | - Hing-Chiu Chang
- Department of Biomedical Engineering, Chinese University of Hong Kong, Hong Kong, China
| | - Hsu-Hsia Peng
- Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan, Republic of China
| | - Ying-Chieh Lee
- Department of Automatic Control Engineering, Feng Chia University, Taichung, Taiwan, Republic of China
| | - Tung-Yang Lee
- Master's Program of Biomedical Informatics and Biomedical Engineering, Feng Chia University, Taichung, Taiwan, Republic of China
- Cheng Ching Hospital, Taichung, Taiwan, Republic of China
| | - Chang-Hsien Liou
- Department of Medical Imaging, China Medical University Hsinchu Hospital, 199, Sec. 1, Xinglong Rd., Zhubei City, Hsinchu County, 302, Taiwan, Republic of China
- Institute of Nuclear Engineering and Science, National Tsing Hua University, Hsinchu, Taiwan, Republic of China
| | - Tz-Feng Lin
- Department of Fiber and Composite Materials, Feng Chia University, Taichung, Taiwan, Republic of China
| | - Fatt-Yang Chew
- Department of Medical Imaging, China Medical University Hospital, Taichung, Taiwan, Republic of China
- Department of Radiology, School of Medicine, China Medical University, Taichung, Taiwan, Republic of China
| | - Ruey-Hwang Chou
- Graduate Institute of Biomedical Sciences, China Medical University, Taichung, 406, Taiwan, Republic of China.
- Center for Molecular Medicine, China Medical University Hospital, Taichung, Taiwan, Republic of China.
- Department of Medical Laboratory and Biotechnology, Asia University, Taichung, Taiwan, Republic of China.
| | - Chun-Jung Juan
- Department of Medical Imaging, China Medical University Hsinchu Hospital, 199, Sec. 1, Xinglong Rd., Zhubei City, Hsinchu County, 302, Taiwan, Republic of China.
- Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan, Republic of China.
- Department of Radiology, School of Medicine, China Medical University, Taichung, Taiwan, Republic of China.
| |
Collapse
|
2
|
Barham M, Kuroda M, Yoshimura Y, Hamada K, Khasawneh A, Sugimoto K, Konishi K, Tekiki N, Sugianto I, Bamgbose BO, Ishizaka H, Shimizu Y, Nakamitsu Y, Al-Hammad WE, Kamizaki R, Kurozumi A, Matsushita T, Ohno S, Asaumi J. Evaluation of calculation processes of apparent diffusion coefficient subtraction method (ASM) imaging. PLoS One 2023; 18:e0282462. [PMID: 36848353 PMCID: PMC9970062 DOI: 10.1371/journal.pone.0282462] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2021] [Accepted: 02/16/2023] [Indexed: 03/01/2023] Open
Abstract
A number of restricted diffusion (RD) imaging techniques, such as diffusion kurtosis (DK) imaging and Q space imaging, have been developed and proven to be useful for the diagnosis of diseases, including cerebral gliomas and cerebrovascular infarction. In particular, apparent diffusion coefficient (ADC) subtraction method (ASM) imaging has become available recently as a novel RD imaging technique. ASM is based on the difference between the ADC values in an image pair of two ADC maps, ADC basic (ADCb) and ADC modify (ADCm), which are created from diffusion-weighted images taken using short and long effective diffusion times, respectively. The present study aimed to assess the potential of different types of ASM imaging by comparing them with DK imaging which is the gold-standard RD imaging technique. In the present basic study using both polyethylene glycol phantom and cell-containing bio-phantom, three different types of ASM images were created using different calculation processes. ASM/A is an image calculated by dividing the absolute difference between ADCb and ADCm by ADCb several times. By contrast, ASM/S is an image created by dividing the absolute difference between ADCb and ADCm by the standard deviation of ADCb several times. As for positive ASM/A image (PASM/A), the positive image, which was resultant after subtracting ADCb from ADCm, was divided by ADCb several times. A comparison was made between the types of ASM and DK images. The results showed the same tendency between ASM/A in addition to both ASM/S and PASM/A. By increasing the number of divisions by ADCb from three to five times, ASM/A images transformed from DK-mimicking to more RD-sensitive images compared with DK images. These observations suggest that ASM/A images may prove useful for future clinical applications in RD imaging protocols for the diagnosis of diseases.
Collapse
Affiliation(s)
- Majd Barham
- Department of Oral and Maxillofacial Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan
| | - Masahiro Kuroda
- Radiological Technology, Graduate School of Health Sciences, Okayama University, Okayama, Japan
- * E-mail:
| | - Yuuki Yoshimura
- Radiological Technology, Graduate School of Health Sciences, Okayama University, Okayama, Japan
- Radiology Diagnosis, Okayama Saiseikai General Hospital, Okayama, Japan
| | - Kentaro Hamada
- Radiological Technology, Graduate School of Health Sciences, Okayama University, Okayama, Japan
| | - Abdullah Khasawneh
- Department of Oral and Maxillofacial Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan
| | - Kohei Sugimoto
- Radiological Technology, Graduate School of Health Sciences, Okayama University, Okayama, Japan
| | - Kohei Konishi
- Radiological Technology, Graduate School of Health Sciences, Okayama University, Okayama, Japan
| | - Nouha Tekiki
- Department of Oral and Maxillofacial Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan
| | - Irfan Sugianto
- Department of Oral and Maxillofacial Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan
| | - Babatunde O. Bamgbose
- Department of Oral and Maxillofacial Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan
| | - Hinata Ishizaka
- Radiological Technology, Graduate School of Health Sciences, Okayama University, Okayama, Japan
| | - Yudai Shimizu
- Department of Oral and Maxillofacial Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan
| | - Yuki Nakamitsu
- Radiological Technology, Graduate School of Health Sciences, Okayama University, Okayama, Japan
| | - Wlla E. Al-Hammad
- Department of Oral and Maxillofacial Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan
| | - Ryo Kamizaki
- Radiological Technology, Graduate School of Health Sciences, Okayama University, Okayama, Japan
| | - Akira Kurozumi
- Central Division of Radiology, Okayama University Hospital, Okayama, Japan
| | - Toshi Matsushita
- Central Division of Radiology, Okayama University Hospital, Okayama, Japan
| | - Seiichiro Ohno
- Central Division of Radiology, Okayama University Hospital, Okayama, Japan
| | - Junichi Asaumi
- Department of Oral and Maxillofacial Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan
| |
Collapse
|
3
|
Development of a standard phantom for diffusion-weighted magnetic resonance imaging quality control studies: A review. POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING 2022. [DOI: 10.2478/pjmpe-2022-0020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Abstract
Various materials and compounds have been used in the design of diffusion-weighted magnetic resonance imaging (DWMRI) phantoms to mimic biological tissue properties, including diffusion. This review thus provides an overview of the preparations of the various DW-MRI phantoms available in relation to the limitations and strengths of materials/solutions used to fill them. The narrative review conducted from relevant databases shows that synthesizing all relevant compounds from individual liquids, gels, and solutions based on their identified strengths could contribute to the development of a novel multifunctional DW-MRI phantom. The proposed multifunctional material at varied concentrations, when filled into a multi-compartment Perspex container of cylindrical or spherical geometry, could serve as a standard DW-MRI phantom. The standard multifunctional phantom could potentially provide DW-MRI quality control test parameters in one study session.
Collapse
|