1
|
Yang F, Dong Y, Bai C, Alzogool M, Wang Y. Bibliometric and visualized analysis of myopic corneal refractive surgery research: from 1979 to 2022. Front Med (Lausanne) 2023; 10:1141438. [PMID: 37575980 PMCID: PMC10416457 DOI: 10.3389/fmed.2023.1141438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Accepted: 07/14/2023] [Indexed: 08/15/2023] Open
Abstract
Background Myopic corneal refractive surgery is one of the most prevalent ophthalmic procedures for correcting ametropia. This study aimed to perform a bibliometric analysis of research in the field of corneal refractive surgery over the past 40 years in order to describe the current international status and to identify most influential factors, while highlighting research hotspots. Methods A bibliometric analysis based on the Web of Science Core Collection (WoSCC) was used to analyze the publication trends in research related to myopic corneal refractive surgery. VOSviewer v.1.6.10 was used to construct the knowledge map in order to visualize the publications, distribution of countries, international collaborations, author productivity, source journals, cited references, keywords, and research hotspots in this field. Results A total of 4,680 publications on myopic corneal refractive surgery published between 1979 and 2022 were retrieved. The United States has published the most papers, with Emory University contributing to the most citations. The Journal of Cataract and Refractive Surgery published the greatest number of articles, and the top 10 cited references mainly focused on outcomes and wound healing in refractive surgery. Previous research emphasized "radial keratotomy (RK)" and excimer laser-associated operation methods. The keywords containing femtosecond (FS) laser associated with "small incision lenticule extraction (SMILE)" and its "safety" had higher burst strength, indicating a shift of operation methods and coinciding with the global trends in refractive surgery. The document citation network was clustered into five groups: (1) outcomes of refractive surgery: (2) preoperative examinations for refractive surgery were as follows: (3) complications of myopic corneal refractive surgery; (4) corneal wound healing and cytobiology research related to photorefractive laser keratotomy; and (5) biomechanics of myopic corneal refractive surgery. Conclusion The bibliometric analysis in this study may provide scholars with valuable to information and help them better understand the global trends in myopic corneal refractive surgery research frontiers. Two stages of rapid development occurred around 1991 and 2013, shortly after the innovation of PRK and SMILE surgical techniques. The most cited articles mainly focused on corneal wound healing, clinical outcomes, ocular aberration, corneal ectasia, and corneal topography, representing the safety of the new techniques.
Collapse
Affiliation(s)
- Fang Yang
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China
- Department of Ophthalmology, Renmin Hospital, Hubei University of Medicine, Shiyan, China
| | - Yi Dong
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China
- Tianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Nankai University Affiliated Eye Hospital, Tianjin, China
| | - Chen Bai
- Department of General Surgery, Taihe Hospital, Hubei University of Medicine, Shiyan, China
| | - Mohammad Alzogool
- Tianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Nankai University Affiliated Eye Hospital, Tianjin, China
- School of Medicine, Nankai University, Tianjin, China
| | - Yan Wang
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China
- Tianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Nankai University Affiliated Eye Hospital, Tianjin, China
- Nankai Eye Institute, Nankai University, Tianjin, China
| |
Collapse
|
2
|
Zaldivar R, Zaldivar R, Gordillo CH, Adamek P. Visual Acuity Improvement in Low, Moderate and High Myopia After Posterior-Chamber Phakic Implantable Collamer Lens Surgery in a Large Patient Cohort. Clin Ophthalmol 2023; 17:1179-1185. [PMID: 37096208 PMCID: PMC10122501 DOI: 10.2147/opth.s407492] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Accepted: 04/11/2023] [Indexed: 04/26/2023] Open
Abstract
Purpose To compare best-corrected visual acuity (BCVA) before and after implantable collamer lens (ICL) surgery in patients with low, moderate and high myopia. Methods A single-centre, prospective, registry-based study involving patients with myopia who received ICLs between October 2018 and August 2020. The study population was divided into three groups of subjects with low (from 0 to -6 D), moderate (-6 to -10 D) and high myopia (more than -10 D). We analysed uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), spherical equivalent (SE), differences between BCVA pre- and 1-month postoperative, and line gain in BCVA 1 month after surgery. Results A total of 770 eyes belonging to 473 patients were surgically intervened during the study period, of which 692 eyes completed 1 month of postoperative follow-up and were included in the study population. At 1-month follow-up, 478 eyes (69%) achieved a BCVA of 20/20, 599 (87%) obtained 20/25 or better, and 663 (96%) had a BCVA of 20/40 or better. We identified a significant improvement in BCVA (baseline 0.15±0.2 logMAR vs follow-up 0.07±0.2 logMAR, p<0.0001) and a significant reduction in SE (baseline -9.23±4.1 D, vs follow-up -0.21±0.8 D, p<0.0001), with a significant relationship between preoperative SE and line gain (r = -0.46, p<0.0001). We identified a significantly higher line gain among eyes with higher degrees of myopia (low myopia 0.22±0.69 lines compared to moderate myopia 0.56±1.1 lines and high myopia 1.51±1.9 lines, p<0.0001). Notably, 99.6% of eyes with a high grade of myopia achieved improvement to a low degree (less than -6 D) at follow-up. The safety and efficacy indexes were 0.083±0.1 and -0.001±0.1, respectively. Conclusion In this large patient cohort, ICL surgery was related to a significant line gain in BCVA, particularly among eyes with higher degrees of myopia.
Collapse
Affiliation(s)
- Roger Zaldivar
- Surgery Department, Instituto Zaldivar, Mendoza, Argentina
- Correspondence: Roger Zaldivar, Instituto Zaldivar, Av. Emilio Civit 701, Mendoza, Argentina, Email
| | | | | | - Pablo Adamek
- Surgery Department, Instituto Zaldivar, Mendoza, Argentina
| |
Collapse
|
3
|
Ormonde S. Refractive surgery for keratoconus. Clin Exp Optom 2021; 96:173-82. [DOI: 10.1111/cxo.12051] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2012] [Revised: 01/31/2013] [Accepted: 02/03/2013] [Indexed: 11/28/2022] Open
Affiliation(s)
- Sue Ormonde
- Department of Ophthalmology, University of Auckland, Auckland, New Zealand,
| |
Collapse
|
4
|
Singh A, Gour A, Dave A, Chouhan L, Buckshey A, Mathur U. Effect of timolol maleate (0.5%) in the management of myopic regression post laser-assisted in-situ keratomileusis: Clinical and topographical outcomes. Indian J Ophthalmol 2020; 68:2990-2994. [PMID: 33229683 PMCID: PMC7856950 DOI: 10.4103/ijo.ijo_1503_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Purpose The aim of this study was to analyze the effect of timolol maleate (0.5%) eye drops in the treatment of myopic regression after laser-assisted in-situ keratomileusis (LASIK). Methods The study was conducted at a tertiary care eye hospital in north India between April 2017 & March 2018 as a prospective interventional study. Patients who underwent uneventful myopic LASIK with hansatome mechanical keratome and presented with regression were included in the study. Baseline demographic characteristics, time to presentation with regression best-corrected visual acuity (BCVA), refraction, intraocular pressure, central corneal thickness and keratometry were recorded at baseline and at each follow-up visit. The enrolled patients were prescribed timolol maleate (0.5%) eyedrops twice daily. They were followed up every month till 3 months on timolol maleate (0.5%) eyedrops and at 6 months post stopping the treatment. Results Twenty-nine eyes of 15 patients were enrolled in the study. Mean pre LASIK spherical equivalent (SE) was - 7.48 ± 2.9 Diopters (Range-3.125 to -11.75 Diopters) and mean regression spherical equivalent was -1.02 ± 1.1 Diopters. There was a decrease in mean SE from presentation (intervention start point) up to 6 months follow-up (-1.34 ± 0.89 to -0.30 ± 0.29 Diopters). While posterior corneal curvature (K1 and K2 Back) changed significantly over treatment period (P = 0.0029, P = 0.0024 respectively), changes in anterior corneal curvature (K1 and K2 Front) were not significant (P = 0.05, P = 0.06 respectively). Central corneal thickness (CCT) and intraocular pressure (IOP) did not change significantly over treatment course. Conclusion Timolol maleate (0.5%) eyedrop is an effective modality for the treatment of refractive regression post LASIK circumventing the need for laser re-treatment in such patients. The most probable mechanism is reversal of the anterior bowing of the cornea in response to intraocular pressure changes.
Collapse
Affiliation(s)
- Aastha Singh
- Department of Cornea and Refractive Surgery, Dr. Shroff's Charity Eye Hospital, New Delhi, India
| | - Abha Gour
- Department of Cornea and Refractive Surgery, Dr. Shroff's Charity Eye Hospital, New Delhi, India
| | - Abhishek Dave
- Department of Cornea and Refractive Surgery, Dr. Shroff's Charity Eye Hospital, New Delhi, India
| | - Lokesh Chouhan
- Department of Biostatistics, Dr. Shroff's Charity Eye Hospital, New Delhi, India
| | | | - Umang Mathur
- Department of Cornea and Refractive Surgery, Dr. Shroff's Charity Eye Hospital, New Delhi, India
| |
Collapse
|
5
|
Diagnostic Sensitivity of Different Reference Bodies When Using Scheimpflug Tomography in a Myopic Population with Keratoconus. J Ophthalmol 2019; 2019:2593404. [PMID: 31396409 PMCID: PMC6668563 DOI: 10.1155/2019/2593404] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2019] [Revised: 06/17/2019] [Accepted: 06/25/2019] [Indexed: 01/01/2023] Open
Abstract
Purpose To establish which reference body offers the greatest sensitivity in keratoconus (KC) diagnosis, obtain normative data for the myopic population with toric ellipsoid reference bodies, and determine the cutoff points for a population with KC. Methods A retrospective, observational study of the entire Scheimpflug tomographer database of the Fundación Jiménez Díaz in Madrid was conducted to identify a normal myopic and a KC myopic population. Three different reference bodies were tested on all patients: best fit sphere (BFS), best fit toric ellipsoid with fixed eccentricity (BFTEFE), and best fit toric ellipsoid (BFTE). Anterior and posterior elevation measurements at the apex and thinnest point were recorded, as well as the root mean square of posterior elevations (RMS-P). Normative data were extracted, and receiver operating characteristic (ROC) curves were generated to obtain cutoff points between the normal and KC population. Results A total of 301 eyes were included, comprising 219 normal myopic and 82 myopic KC eyes. BFS and BFTEFE produced the best results when measuring posterior elevation at the thinnest point. BFTE had better sensitivity with the RMS-P. From all measurements, best sensitivity (100%) was achieved with a cutoff point of 8 μm of posterior elevation at the thinnest point using the BFTEFE. BFTE was found to hide the cone in certain patients. Conclusions Posterior elevation measured at the thinnest point with a BFTEFE is the best-performing parameter and, therefore, is recommended to discriminate between normal and KC patients within a myopic population.
Collapse
|
6
|
Repeatability of Central Corneal Thickness Measurement Using Rotating Scheimpflug Camera in Dry and Normal Eyes. Eye Contact Lens 2017; 44 Suppl 2:S29-S32. [PMID: 28244934 DOI: 10.1097/icl.0000000000000373] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE To compare the repeatability of central corneal thickness (CCT) measurement using the Pentacam between dry eyes and healthy eyes, as well as to investigate the effect of artificial tears on CCT measurement. METHODS The corneal thicknesses of 34 patients with dry eye and 28 healthy subjects were measured using the Pentacam. One eye from each subject was assigned randomly to a repeatability test, wherein a single operator performed three successive CCT measurements time points-before and 5 min after instillation of one artificial teardrop. The repeatability of measurements was assessed using the coefficient of repeatability and the intraclass correlation coefficient. RESULTS The coefficient of repeatability values of the CCT measurements in dry and healthy eyes were 24.36 and 10.69 μm before instillation, and 16.85 and 9.72 μm after instillation, respectively. The intraclass correlation coefficient was higher in healthy eyes than that of in dry eyes (0.987 vs. 0.891), and it had improved significantly in dry eyes (0.948) after instillation of one artificial teardrop. The CCT measurement fluctuated in dry eyes (repeated-measures analysis of variance, P<0.001), whereas no significant changes were detected in healthy eyes, either before or after artificial tear instillation. CONCLUSIONS Central corneal thickness measurement is less repeatable in dry eyes than in healthy eyes. Artificial tears improve the repeatability of CCT measurements obtained using the Pentacam in dry eyes.
Collapse
|
7
|
Pásztor D, Kolozsvári BL, Csutak A, Berta A, Hassan Z, Ujhelyi B, Gogolák P, Fodor M. Tear Mediators in Corneal Ectatic Disorders. PLoS One 2016; 11:e0153186. [PMID: 27074131 PMCID: PMC4830513 DOI: 10.1371/journal.pone.0153186] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2016] [Accepted: 03/24/2016] [Indexed: 12/31/2022] Open
Abstract
Purpose To compare the concentrations of 11 tear mediators in order to reveal the biochemical difference between pellucid marginal degeneration (PMD) and keratoconus (KC). Methods We have designed a cross-sectional study in which patients with corneal ectasia based on slit-lamp biomicroscopy and Pentacam HR (keratometry values (K1, K2, Kmax), astigmatism, minimal radius of curvature (Rmin), corneal thickness (Apex and Min), indices (surface variation, vertical asymmetry, keratoconus, central keratoconus, height asymmetry and decentration)) were enrolled. Eyes of keratoconic patients were similar to the PMD patients in age and severity (K2, Kmax and Rmin). Non-stimulated tear samples were collected from nine eyes of seven PMD patients, 55 eyes of 55 KC patients and 24 eyes of 24 healthy controls. The mediators’ (interleukin -6, -10, chemokine ligand 5, -8, -10, matrix metalloproteinase (MMP) -9, -13, tissue inhibitor of metalloproteinases (TIMP)-1, tissue plasminogen activator, plasminogen activator inhibitor, nerve growth factor) concentrations were measured using Cytometric Bead Array. Results MMP-9 was the only mediator which presented relevant variances between the two patient groups (p = 0.005). The ratios of MMP-9 and TIMP-1 were 2.45, 0.40 and 0.23 in PMD, KC and the controls, respectively. Conclusion As far as we are aware, this is the first study that aims to reveal the biochemical differences between PMD and KC. Further studies of biomarkers to investigate the precise role of these mediators need to be defined, and it is important to confirm the observed changes in a larger study to gain further insights into the molecular alterations in PMD.
Collapse
Affiliation(s)
- Dorottya Pásztor
- Department of Ophthalmology, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - Bence Lajos Kolozsvári
- Department of Ophthalmology, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - Adrienne Csutak
- Department of Ophthalmology, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - András Berta
- Department of Ophthalmology, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - Ziad Hassan
- Orbident Refractive Surgery and Medical Center, Debrecen, Hungary
| | - Bernadett Ujhelyi
- Department of Ophthalmology, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - Péter Gogolák
- Department of Immunology, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - Mariann Fodor
- Department of Ophthalmology, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
- * E-mail:
| |
Collapse
|
8
|
Wang Y, Cui C, Li Z, Tao X, Zhang C, Zhang X, Mu G. Corneal ectasia 6.5 months after small-incision lenticule extraction. J Cataract Refract Surg 2015; 41:1100-6. [DOI: 10.1016/j.jcrs.2015.04.001] [Citation(s) in RCA: 48] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2014] [Revised: 12/31/2014] [Accepted: 01/01/2015] [Indexed: 10/23/2022]
|
9
|
Moshirfar M, Edmonds JN, Behunin NL, Christiansen SM. Current Options in the Management of Pellucid Marginal Degeneration. J Refract Surg 2014; 30:474-85. [DOI: 10.3928/1081597x-20140429-02] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2013] [Accepted: 03/11/2014] [Indexed: 11/20/2022]
|
10
|
Mehravaran S, Hashemi H, KhabazKhoob M, Fotouhi A. Distribution of radii of curvature of anterior and posterior best fit sphere in a normal population: The Tehran Eye Study. Cont Lens Anterior Eye 2013; 36:186-90. [DOI: 10.1016/j.clae.2013.02.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2012] [Revised: 01/22/2013] [Accepted: 02/21/2013] [Indexed: 11/27/2022]
|
11
|
Almubrad TM, Alshehri FH, Ogbuehi KC, Osuagwu UL. Comparison of the influence of nonpreserved oxybuprocaine and a preserved artificial tear (thera tears) on human corneal thickness measured by two pachymeters. J Ocul Pharmacol Ther 2013; 29:462-8. [PMID: 23331053 DOI: 10.1089/jop.2012.0215] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
PURPOSE To compare the effect of nonpreserved oxybuprocaine and preserved artificial tears on central corneal thickness (CCT) obtained by 2 pachymeters. METHODS In this prospective, placebo-controlled study, involving a random sample of 100 eyes of 50 subjects, aged 24±2.3 years, CCT readings were obtained in 2 separate sessions with the Topcon SP-3000P and ultrasound pachymetry (USP), respectively, before, 5 and 10 min after instillation of a drop each of either oxybuprocaine hydrochloride (oxybuprocaine HCl) (group 1) or carboxymethylcellulose sodium, thera tears (group 2), and placebo. RESULTS The baseline mean CCT for SP-3000P was 509±38 μm and 542±36 μm for USP. No statistical significant differences between baseline CCTs (P>0.05 for both devices) in both groups. In both group experimental eyes, neither SP-3000P nor USP-measured CCTs varied significantly from the control eyes at 5 (P>0.05) and 10 (P>0.05) mins postinstillation of drops in both sessions. In group one, the 95% confidence intervals (CIs) for the SP-3000P CCTs were similar at 5 (-16 to 17 μm) and 10 min (-16 to 17 μm), but in the USP-measured CCTs, it was wider at 10 min (-41 to 46 μm) than at 5 min (-30 to 41 μm) postinstillation. In group two, the 95% CIs at 5 and 10 mins postinstillation, respectively, ranged between -20 and 47 μm, -21 and 43 μm (SP-3000P) and -29 and 23 μm, -26 and 23 μm (USP). Within groups and between groups, variations in CCT were similar at both times intervals in all comparisons. CONCLUSION Although oxybuprocaine HCl and thera tears consistently did not affect the mean CCT obtained by both devices at both time intervals, variation in SP-3000P measured CCT was more consistent in both sessions and narrower in relation to USP-measured CCT. It may be reasonable to suggest that measurements of CCT in normal patients be taken before examinations requiring instillation of anesthetics or such measurements when obtained postinstillation of either oxybuprocaine or preserved artificial tears be interpreted with caution.
Collapse
Affiliation(s)
- Turki M Almubrad
- Corneal Research Chair, Department of Optometry and Vision Sciences, College of Applied Medical Sciences, King Saud University, Riyadh, Kingdom of Saudi Arabia
| | | | | | | |
Collapse
|
12
|
Shojaei A, Eslani M, Vali Y, Mansouri M, Dadman N, Yaseri M. Effect of timolol on refractive outcomes in eyes with myopic regression after laser in situ keratomileusis: a prospective randomized clinical trial. Am J Ophthalmol 2012; 154:790-798.e1. [PMID: 22935601 DOI: 10.1016/j.ajo.2012.05.013] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2012] [Revised: 05/15/2012] [Accepted: 05/15/2012] [Indexed: 11/26/2022]
Abstract
PURPOSE To compare the effects of timolol on refractive outcomes in eyes with myopic regression after laser in situ keratomileusis (LASIK) with a control-matched group. DESIGN Prospective, randomized, parallel-controlled, double-masked clinical trial. A computer-generated randomization list based on random block permutation (length 4 to 8) was used for treatment allocation. METHODS setting: Basir Eye Center, Tehran, Iran. PATIENT POPULATION Of 124 eyes with myopic regression after LASIK using Technolas 217-Z, 45 eyes in each group were analyzed. INTERVENTION Patients were randomly assigned into either Group 1, who received timolol 0.5% eye drops, or Group 2, who received artificial tears for 6 months. MAIN OUTCOME MEASURE Spherical equivalent (SE) at 6 months posttreatment. RESULTS In Group 1, SE improved from -1.48 ± 0.99 diopter (D) before treatment to -0.88 ± 0.91 D and -0.86 ± 0.93 D 6 months after treatment and 6 months after timolol discontinuation, respectively (P < .001). In Group 2, it was -1.57 ± 0.67 D, -1.83 ± 0.76 D, and -1.91 ± 0.70 D, respectively (P < .001). SE was significantly better in Group 1 6 months after treatment and 6 months after discontinuation of treatment (P < .001 for both comparisons). There was a 0.26 D decrease in SE improvement every 4 months after the surgery in the Group 1 (P < .001). CONCLUSIONS Timolol application is effective for the treatment of myopic regression after LASIK compared with control group. Its effects last for at least 6 months after its discontinuation.
Collapse
|
13
|
Haddad W, Fadlallah A, Dirani A, El Rami H, Fahd D, Khanafer D, Fahed S. Comparison of 2 types of intrastromal corneal ring segments for keratoconus. J Cataract Refract Surg 2012; 38:1214-21. [DOI: 10.1016/j.jcrs.2012.02.039] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2011] [Revised: 01/26/2012] [Accepted: 02/01/2012] [Indexed: 10/28/2022]
|
14
|
Abstract
PURPOSE To investigate the effect of oxybuprocaine eye drops on corneal volume (CV) and corneal thickness measurements. METHODS Central corneal thickness (CCT), corneal thinnest point (CTP), and CV of 78 eyes of 78 healthy volunteers were measured with Pentacam, before and 5 min after the administration of oxybuprocaine eye drops. The fellow non-anesthetized eyes were used as control. RESULTS Before topical anesthesia, the mean CCT was 546.76 ± 35.3 μm, after anesthesia, it was 547.76 ± 36.56 μm (p = 0.86). In the fellow eyes, the first mean CCT was 548.82 ± 35.2 μm and the second was 547.55 ± 35.9 μm (p = 0.82). The mean CTP before anesthesia was 543.99 ± 35.23 μm, after it was 544.89 ± 36.3 μm (p = 0.88). In the fellow eyes, the first mean CTP was 544.15 ± 35.35 μm and the second was 542.81 ± 36 μm (p = 0.81). Before topical anesthesia, the mean CV was 60.55 ± 3.84 mm, after it was 60.66 ± 3.97 mm (p = 0.86). In the fellow eyes, the first mean CV was 60.93 ± 3.87 mm and the second was 60.73 ± 4 mm (p = 0.75). CONCLUSIONS Oxybuprocaine eye drops do not appear to induce a significant corneal swelling and do not affect the measurements when comparing CCT measured with optical or ultrasound devices.
Collapse
|
15
|
Clinical characterization of corneal ectasia after myopic laser in situ keratomileusis based on anterior corneal aberrations and internal astigmatism. J Cataract Refract Surg 2011; 37:1291-9. [DOI: 10.1016/j.jcrs.2010.12.063] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2010] [Revised: 12/13/2010] [Accepted: 12/13/2010] [Indexed: 11/20/2022]
|
16
|
|
17
|
|
18
|
Kato N, Toda I, Kawakita T, Sakai C, Tsubota K. Topography-guided conductive keratoplasty: treatment for advanced keratoconus. Am J Ophthalmol 2010; 150:481-489.e1. [PMID: 20692643 DOI: 10.1016/j.ajo.2010.05.014] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2010] [Revised: 05/12/2010] [Accepted: 05/13/2010] [Indexed: 11/19/2022]
Abstract
PURPOSE To evaluate the use of topography-guided conductive keratoplasty in eyes with keratoconus. DESIGN Interventional case series. METHODS We examined 21 eyes in 21 patients with advanced keratoconus. Topography-guided conductive keratoplasty was performed with intraoperative monitoring of corneal astigmatism using a surgical keratometer. Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), corneal topography, manifest refraction, intraocular pressure (IOP), corneal endothelial cell counts, complications, and eventual outcomes were evaluated. RESULTS UCVA (logarithm of the minimal angle of resolution [logMAR]), which was 1.65 ± 0.49 preoperatively, improved to 1.04 ± 0.64 at 1 week (P < .001) and 1.12 ± 0.61 at 1 month after surgery (P < .001). BSCVA, which was 1.02 ± 0.56 preoperatively, improved to 0.76 ± 0.65 at 1 week (P = .026) and 0.76 ± 0.60 at 1 month after surgery (P = .003). Manifest refraction, which was -15.13 ± 6.66 diopters (D) before surgery, declined to -9.97 ± 6.71 D at 1 month after surgery (P = .002). Although corneal topography reverted to the preoperative pattern and UCVA and BSCVA also regressed toward preoperative values, 12 of 21 eyes were better able to tolerate and conduct normal daily activities using contact lenses. Five subjects have undergone or are considering corneal transplantation after unsatisfactory postoperative results. No serious perioperative complication was observed. CONCLUSIONS Topography-guided conductive keratoplasty may be effective in reshaping corneal configuration in eyes with keratoconus, without serious complications, and possibly contributed to avoiding or delaying corneal transplantation.
Collapse
Affiliation(s)
- Naoko Kato
- Department of Ophthalmology, School of Medicine, Keio University, Tokyo, Japan.
| | | | | | | | | |
Collapse
|
19
|
Kubaloglu A, Sari ES, Cinar Y, Koytak A, Kurnaz E, Piñero DP, Ozerturk Y. A single 210-degree arc length intrastromal corneal ring implantation for the management of pellucid marginal corneal degeneration. Am J Ophthalmol 2010; 150:185-192.e1. [PMID: 20570241 DOI: 10.1016/j.ajo.2010.03.020] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2009] [Revised: 03/08/2010] [Accepted: 03/10/2010] [Indexed: 11/18/2022]
Abstract
PURPOSE To determine the visual and refractive outcomes of 210-degree arc length intrastromal corneal ring segment (ICRS) implantation in eyes with pellucid marginal corneal degeneration (PMCD). DESIGN Retrospective, consecutive case series. METHODS Sixteen consecutive eyes of 10 patients who underwent a single 210-degree ICRS implantation by femtosecond laser for the management of PMCD and completed at least 1 year follow-up were included. A complete ophthalmic examination was performed preoperatively and postoperatively, including uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest spherical and cylindrical refractions, spherical equivalent, and keratometric readings. RESULTS The mean follow-up period was 30.7 months (range 12 to 36 months). No intraoperative complication was observed. White deposits around the segments were noted in 2 of 16 eyes (12.5%) at the first postoperative year. The mean UCVA showed significant improvement, from 1.69 +/- 1.02 logarithm of the minimal angle of resolution (logMAR) preoperatively to 0.64 +/- 0.43 logMAR at the 36th month (n = 11, P < .001). The mean preoperative BSCVA was 0.88 +/- 0.68 logMAR; after 36 months, this improved to 0.35 +/- 0.34 (P < .001). At the 36th month, UCVA was improved in all eyes (n = 11, range: gain of 1 to 6 lines), whereas BSCVA was improved in 9 eyes (81.8%, range: gain of 2 to 7 lines) and remained unchanged in 2 eyes (18.1%); UCVA was 20/40 or better in 3 eyes (27%) and BSCVA was 20/40 or better in 8 eyes (72.7%). There was a significant reduction in the spherical equivalent refractive error, from -4.40 +/- 1.85 diopters (D) preoperatively to -1.86 +/- 0.60 D (P < .001), and the mean maximum keratometric power decreased from 49.70 +/- 4.32 D to 46.08 +/- 2.84 D (P < .001) after 36 months. The mean cylindrical refraction decreased from -4.39 +/- 1.86 D preoperatively to -2.38 +/- 1.35 D at 36 months (P < .001). CONCLUSION A single 210-degree arc length ICRS implantation using a femtosecond laser for patients with PMCD provides good visual and refractive outcomes.
Collapse
Affiliation(s)
- Anil Kubaloglu
- Dr Lütfi Kirdar Kartal Training and Research Hospital, Istanbul, Turkey
| | | | | | | | | | | | | |
Collapse
|
20
|
Alfonso JF, Fernández-Vega L, Lisa C, Fernandes P, González-Méijome JM, Montés-Micó R. Collagen copolymer toric posterior chamber phakic intraocular lens in eyes with keratoconus. J Cataract Refract Surg 2010; 36:906-16. [PMID: 20494760 DOI: 10.1016/j.jcrs.2009.11.032] [Citation(s) in RCA: 63] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2009] [Revised: 11/26/2009] [Accepted: 11/28/2009] [Indexed: 11/27/2022]
Abstract
PURPOSE To assess the safety, efficacy, stability, and predictability of collagen copolymer toric phakic intraocular lens (pIOL) implantation to correct myopia and astigmatism in eyes with keratoconus. SETTING Fernández-Vega Ophthalmological Institute, Oviedo, Spain. METHODS This prospective study comprised keratoconic eyes that had implantation of a toric Intraocular Collamer Lens. Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, and postoperative complications were evaluated 1, 3, 6, and 12 months postoperatively. RESULTS Preoperatively, the mean spherical equivalent in the 30 eyes (21 patients) was -5.38 diopters (D) +/- 3.26 (SD) (range -13.50 to -0.63 D) and the mean cylinder, -3.48 +/- 1.24 D (range -1.75 to -6.00 D). At 12 months, 86.7% of the eyes were within +/-0.50 D of the attempted refraction and all eyes were within +/-1.00 D. For the astigmatic components J0 and J45, 83.3% of eyes and 86.7% of eyes, respectively, were within +/-0.50 D. The mean Snellen UDVA was 0.81 +/- 0.20 and the mean CDVA, 0.83 +/- 0.18; CDVA was 20/40 or better in 29 eyes 96.7% of eyes and 20/25 or better in 22 eyes (73.3%). No eyes lost more than 2 lines of CDVA; 29 eyes (96.7%) maintained or gained 1 or more lines. The efficacy index was 1.07 and the safety index, 1.16. There were no complications or adverse events. CONCLUSIONS The results confirm that toric ICL implantation is a predictable, effective procedure to correct ametropia in eyes with keratoconus. Predictability and stability were achieved early and remained fairly stable up to 12 months.
Collapse
Affiliation(s)
- José F Alfonso
- Fernández-Vega Ophthalmological Institute, Surgery Department, School of Medicine, University of Oviedo, Oviedo, Spain.
| | | | | | | | | | | |
Collapse
|
21
|
Comparison of the changes in corneal biomechanical properties after photorefractive keratectomy and laser in situ keratomileusis. Cornea 2009; 28:765-9. [PMID: 19574911 DOI: 10.1097/ico.0b013e3181967082] [Citation(s) in RCA: 83] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To compare the postoperative biomechanical properties of the cornea after photorefractive keratectomy (PRK) and after laser in situ keratomileusis (LASIK) in eyes with myopia. METHODS We retrospectively examined 27 eyes of 16 patients undergoing PRK and 31 eyes of 16 patients undergoing LASIK for the correction of myopia. Corneal hysteresis (CH) and corneal resistance factor (CRF) were measured with Ocular Response Analyzer before and 3 months after surgery. We also investigated the relationship between these biomechanical changes and the amount of myopic correction. RESULTS The CH was decreased significantly from 10.8 +/- 1.3 (mean +/- SD) mmHg to 9.2 +/- 1.6 mmHg after PRK (P < 0.001), and from 10.8 +/- 1.4 mmHg to 8.6 +/- 0.9 mmHg after LASIK (P < 0.001). The CRF was also decreased significantly, from 10.3 +/- 1.5 mmHg to 8.4 +/- 1.8 mmHg after PRK (P < 0.001), and from 10.3 +/- 1.5 mmHg to 7.7 +/- 1.3 mmHg after LASIK (P < 0.001). The amount of decrease in CH and CRF was significantly larger after LASIK than after PRK (P = 0.04). There was a significant correlation between the amount of myopic correction and changes in biomechanical properties after PRK (r = -0.61, P < 0.01 for CH, r = -0.41, P < 0.05 for CRF) and LASIK (r = -0.37, P < 0.05 for CH, r = -0.45, P < 0.05 for CRF). CONCLUSIONS Both PRK and LASIK can affect the biomechanical strength of the cornea depending on the amount of myopic correction. The amount of biomechanical changes is larger after LASIK than after PRK. From a biomechanical viewpoint, PRK may be a less invasive surgical approach for the correction of myopia than LASIK.
Collapse
|
22
|
Reinstein DZ, Archer TJ, Gobbe M. Stability of LASIK in topographically suspect keratoconus confirmed non-keratoconic by Artemis VHF digital ultrasound epithelial thickness mapping: 1-year follow-up. J Refract Surg 2009; 25:569-77. [PMID: 19662913 DOI: 10.3928/1081597x-20090610-02] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To determine the 1-year stability of LASIK in corneas with topographic suspect keratoconus confirmed as non-keratoconic by epithelial thickness mapping. METHODS This was a retrospective case/control comparative study. Eyes suspected of keratoconus using criteria based mainly on Atlas (Carl Zeiss Meditec AG) and Orbscan II (Bausch & Lomb) topography were scanned by Artemis very high-frequency digital ultrasound (ArcScan Inc). Keratoconus was confirmed if the epithelial thickness profile showed relative epithelial thinning coincident with an eccentric posterior elevation best-fit sphere apex. Laser in situ keratomileusis was performed in all eyes where keratoconus was excluded by finding relatively thicker epithelium or not finding localized thinning over the topographically suspected cone. Patients were followed for 1 year after LASIK. A control group was generated matched within 0.50 diopter (D) for sphere, cylinder, and spherical equivalent refraction (SEQ) to compare refractive stability. RESULTS The average change in SEQ between 3 and 12 months was -0.10+/-0.30 D for the suspect keratoconus group and -0.10+/-0.28 D for controls. No statistically significant difference in shift from 3 months to 12 months in SEQ or cylinder between groups was noted. No statistically significant change in best spectacle-corrected visual acuity between groups was noted, with no eye losing 2 lines and 5% in the suspect keratoconus group and 2% of controls losing 1 line. No cases of ectasia were observed in either group. CONCLUSIONS Suspect keratoconus, confirmed to be non-keratoconic by epithelial thickness profile criteria demonstrated equal stability to control eyes 1 year after LASIK. Epithelial thickness profiles may enable LASIK to be performed in eyes that would otherwise have been excluded due to topographic suspect keratoconus. Further follow-up is being carried out.
Collapse
|
23
|
Sierra Wilkinson P, Davis EA, Hardten DR. LASIK. Ophthalmology 2009. [DOI: 10.1016/b978-0-323-04332-8.00019-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022] Open
|
24
|
Kato N, Toda I, Hori-Komai Y, Sakai C, Tsubota K. Five-Year Outcome of LASIK for Myopia. Ophthalmology 2008; 115:839-844.e2. [PMID: 17900692 DOI: 10.1016/j.ophtha.2007.07.012] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2007] [Revised: 06/18/2007] [Accepted: 07/09/2007] [Indexed: 11/30/2022] Open
Abstract
PURPOSE To investigate the efficacy and safety of LASIK over a 5-year postoperative period. DESIGN Observational case series. PARTICIPANTS We examined 779 eyes in 402 patients with myopia or myopic astigmatism who underwent LASIK to correct their refractive errors and received regular postoperative assessments for 5 years. METHODS Postoperative examinations were performed 1 day; 1 week; 1, 3, and 6 months; and 1, 2, 3, 4, and 5 years after LASIK surgery. MAIN OUTCOME MEASURES We evaluated changes in uncorrected visual acuity (UCVA) (logarithm of the minimum angle of resolution [logMAR]), manifest refraction, best-corrected visual acuity (BCVA) (logMAR), intraocular pressure, corneal thickness, corneal endothelial cell counts, and complications. RESULTS Preoperative UCVA of 1.27 improved to -0.03 at 1 day after surgery and -0.08 at 1 month and revealed minimal but significant decreases thereafter. Postoperative manifest refraction was also improved by surgery, showing minimal but significant regression after 1 year. Final BCVA loss was seen in 10 eyes of 7 patients; in 7 cases, there were obvious reasons such as the progression of cataracts in 3 eyes, epithelial disintegrity due to dry eye in 2 eyes, irregular astigmatism due to flap striae in 1 eye, and age-related macular dystrophy in 1 eye. Intraocular pressure and corneal thickness decreased by 4.0 mmHg and 76.9 microm, respectively, due to surgery, but remained stable throughout the follow-up period. Corneal endothelial cell counts (2689.0+/-232.9 cells/mm(2) before surgery) showed a statistically significant decrease at 5 years after surgery (2658.0+/-183.1 cells/mm(2); 1.2% loss for 5 years), likely within the range due to physiological age-related loss. No serious, vision-threatening, irreversible complication such as keratectasia or progressive endothelial cell loss was observed. CONCLUSION LASIK surgery is an effective and safe procedure for correcting myopia/myopic astigmatism as long as inclusion and exclusion criteria are strictly respected. However, minimal regression occurred during the 5-year investigative period.
Collapse
Affiliation(s)
- Naoko Kato
- Minamiaoyama Eye Clinic, Tokyo, Japan.; Department of Ophthalmology, School of Medicine, Keio University, Tokyo, Japan.
| | | | | | | | | |
Collapse
|
25
|
Randleman JB, Woodward M, Lynn MJ, Stulting RD. Risk Assessment for Ectasia after Corneal Refractive Surgery. Ophthalmology 2008; 115:37-50. [PMID: 17624434 DOI: 10.1016/j.ophtha.2007.03.073] [Citation(s) in RCA: 479] [Impact Index Per Article: 29.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2006] [Revised: 03/30/2007] [Accepted: 03/30/2007] [Indexed: 11/18/2022] Open
Abstract
PURPOSE To analyze the epidemiologic features of ectasia after excimer laser corneal refractive surgery, to identify risk factors for its development, and to devise a screening strategy to minimize its occurrence. DESIGN Retrospective comparative and case-control study. PARTICIPANTS All cases of ectasia after excimer laser corneal refractive surgery published in the English language with adequate information available through December 2005, unpublished cases seeking treatment at the authors' institution from 1998 through 2005, and a contemporaneous control group who underwent uneventful LASIK and experienced a normal postoperative course. METHODS Evaluation of preoperative characteristics, including patient age, gender, spherical equivalent refraction, pachymetry, and topographic patterns; perioperative characteristics, including type of surgery performed, flap thickness, ablation depth, and residual stromal bed (RSB) thickness; and postoperative characteristics including time to onset of ectasia. MAIN OUTCOME MEASURES Development of postoperative corneal ectasia. RESULTS There were 171 ectasia cases, including 158 published cases and 13 unpublished cases evaluated at the authors' institution. Ectasia occurred after LASIK in 164 cases (95.9%) and after photorefractive keratectomy (PRK) in 7 cases (4.1%). Compared with controls, more ectasia cases had abnormal preoperative topographies (35.7% vs. 0%; P<1.0x10(-15)), were significantly younger (34.4 vs. 40.0 years; P<1.0x10(-7)), were more myopic (-8.53 vs. -5.09 diopters; P<1.0x10(-7)), had thinner corneas before surgery (521.0 vs. 546.5 microm; P<1.0x10(-7)), and had less RSB thickness (256.3 vs. 317.3 microm; P<1.0x10(-10)). Based on subgroup logistic regression analysis, abnormal topography was the most significant factor that discriminated cases from controls, followed by RSB thickness, age, and preoperative corneal thickness, in that order. A risk factor stratification scale was created, taking all recognized risk factors into account in a weighted fashion. This model had a specificity of 91% and a sensitivity of 96% in this series. CONCLUSIONS A quantitative method can be used to identify eyes at risk for developing ectasia after LASIK that, if validated, represents a significant improvement over current screening strategies.
Collapse
|
26
|
Late Bacterial Keratitis After Intracorneal Ring Segments (Ferrara Ring) Insertion for Keratoconus. Cornea 2007; 26:1282-4. [DOI: 10.1097/ico.0b013e3181506142] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
27
|
Sonmez B, Doan MP, Hamilton DR. Identification of scanning slit-beam topographic parameters important in distinguishing normal from keratoconic corneal morphologic features. Am J Ophthalmol 2007; 143:401-8. [PMID: 17224117 DOI: 10.1016/j.ajo.2006.11.044] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2006] [Revised: 11/02/2006] [Accepted: 11/03/2006] [Indexed: 11/24/2022]
Abstract
PURPOSE To identify morphologic parameters obtained using scanning slit-beam topography that help distinguish normal from keratoconic corneal morphologic features. DESIGN Observational, retrospective, cross-sectional study. METHODS This retrospective review examined 207 normal eyes of patients undergoing an initial consultation for primary refractive surgery and 42 eyes with clinical keratoconus (KCN). The following parameters were examined and compared between the two groups: astigmatism, central corneal power, irregularity indices at 3 mm (II3) and 5 mm (II5), maximal posterior elevation (MPE) magnitude and location, thinnest optical pachymetry (TOP) magnitude and location, anterior elevation best-fit sphere (ABFS), posterior elevation best-fit sphere (PBFS), the ratio of ABFS to PBFS, the difference between average inferior and average superior K values at 3 mm and 5 mm in both keratometric (I-S K3 and I-S K5) and tangential (I-S T3 and I-S T5) topographic maps, and skewed radial axis at 3 mm (SRAX3) and 5 mm (SRAX5) of the keratometric topography map. RESULTS The II3, II5, MPE magnitude, TOP magnitude, ABFS, PBFS, ABFS-to-PBFS ratio, I-S K at both 3 mm and 5 mm, I-S T at both 3 and 5 mm, and SRAX at 3 mm and 5 mm values were significantly different among the two groups (P < .001). The least-correlated parameters were SRAX3, TOP magnitude, and II3 in the KCN group and I-S K3, amount of astigmatism and MPE magnitude in the normal group. CONCLUSIONS Parameters obtained using scanning slit-beam topography may allow improved differentiation of keratoconic from normal corneal shapes, especially when the poorly correlated intragroup parameters are used.
Collapse
Affiliation(s)
- Baris Sonmez
- The Jules Stein Eye Institute, David Geffen School of Medicine at University of California, Los Angeles, Los Angeles, California 90095, USA
| | | | | |
Collapse
|
28
|
Abstract
PURPOSE To describe the clinical and ultrastructural features of a prominent ectasia of the cornea that occurred 9 years after excimer laser photorefractive keratectomy (PRK). METHODS Analysis of corneal topography and ultrastructural examination by transmission electron microscopy (TEM) were used to assess the ectatic cornea. RESULTS The intended laser ablation in the left eye was 74 microm, and the preoperative ultrasonic pachymetry was 536 microm. Orbscan II (V 3.00; Orbtek, Salt Lake City, UT) observations revealed inferior topographic steepening and protrusion of the anterior and posterior corneal surfaces 13 years after the patient underwent PRK. The least thickness of the cornea was 456 microm. TEM showed that the epithelial basement membrane had degenerated into subepithelial stroma, and apoptotic keratocytes with cell debris on the extracellular matrix were observed in the stroma. However, the endothelial cells were normal. CONCLUSION Clinical examination of an eye that had developed corneal ectasia 9 years after PRK showed forward protrusion of both anterior and posterior corneal surfaces. Ultrastructural examination also revealed a degenerated stroma. However, there was no abnormality of the corneal endothelium.
Collapse
Affiliation(s)
- Hyojin Kim
- Department of Visual Optics, Division of Health Science, Baekseok University, Korea
| | | | | |
Collapse
|
29
|
Reinstein DZ, Srivannaboon S, Archer TJ, Silverman RH, Sutton H, Coleman DJ. Probability Model of the Inaccuracy of Residual Stromal Thickness Prediction to Reduce the Risk of Ectasia After LASIK Part II: Quantifying Population Risk. J Refract Surg 2006; 22:861-70. [PMID: 17124880 DOI: 10.3928/1081-597x-20061101-05] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To derive a statistical model to estimate the rate of excessive keratectomy depth below a selected cut-off residual stromal thickness (RST) given a minimum target RST and specific Clinical Protocol; apply the model to estimate the RST below which ectasia appears likely to occur and back-calculate the safe minimum target RST that should be used given a specific Clinical Protocol. METHODS Myopia and corneal thickness distribution were modeled for a population of 5212 eyes that underwent LASIK. The probability distribution of predicted target RST error (Part I) was used to calculate the rate of excessive keratectomy depth for this series. All treatments were performed using the same Clinical Protocol; one surgeon, Moria LSK-One microkeratome, NIDEK EC-5000 excimer laser, Orbscan pachymetry, and a minimum target RST of 250 microm--the Vancouver Clinical Protocol. The model estimated the RST below which ectasia appears likely to occur and back-calculated the safe minimum target RST. These values were recalculated for a series of microkeratomes using published flap thickness statistics as well as for the Clinical Protocol of one of the authors-the London Clinical Protocol. RESULTS In the series of 5212 eyes, 6 (0.12%) cases of ectasia occurred. The model predicted an RST of 191 microm for ectasia to occur and that a minimum target RST of 329 microm would have reduced the -rate of ectasia to 1: 1,000,000 for the Vancouver Clinical Protocol. The model predicted that the choice of microkeratome varied the rate of ectasia between 0.01 and 11,623 eyes per million and the safe minimum target RST between 220 and 361 microm. The model predicted the rate of ectasia would have been 0.000003: 1,000,000 had the London Clinical Protocol been used for the Vancouver case series. CONCLUSIONS There appears to be no universally safe minimum target RST to assess suitability for LASIK largely due to the disparity in accuracy and reproducibility of microkeratome flap thickness. This model may be used as a tool to evaluate the risk of ectasia due to excessive keratectomy depth and help determine the minimum target RST given a particular Clinical Protocol.
Collapse
Affiliation(s)
- Dan Z Reinstein
- London Vision Clinic, 8 Devonshire Place, London W1G 6HP, United Kingdom.
| | | | | | | | | | | |
Collapse
|
30
|
Qi H, Hao Y, Xia Y, Chen Y. Regression-Related Factors before and after Laser in situ Keratomileusis. Ophthalmologica 2006; 220:272-6. [PMID: 16785760 DOI: 10.1159/000093083] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2005] [Accepted: 11/11/2005] [Indexed: 11/19/2022]
Abstract
The aim of this study was to evaluate the refractive regression-related factors before and after laser in situ keratomileusis (LASIK) for myopia and give a reasonable way to prevent it. The consecutive patients who underwent LASIK from January to June 2004 were reviewed retrospectively. Thirteen eyes from 8 patients with myopic regression and 60 eyes from 42 patients with no myopic regression within 12 months of follow-up were enrolled. We compared the pre- and postoperative data which were associated with regression in the two groups. The mean preoperative intraocular pressure (IOP) was significantly higher in the regression group than in the non-regression group (p = 0.03). During the period of 12 months, the two groups differed in corneal bowing. In the regression group, both posterior and anterior corneal surfaces were significantly bowing (all p < 0.05). In contrast, in the non-regression group, both posterior and anterior surfaces were relatively stable (all p > 0.05). The higher preoperative IOP and the progressive postoperative biomechanical bowing in the posterior and anterior surfaces of the cornea are two factors related to myopic regression in this study. Lowering the IOP preoperatively and postoperatively may be an effective way to prevent the myopic regression after LASIK.
Collapse
Affiliation(s)
- Hong Qi
- Peking University Eye Center, Peking University Third Hospital, Beijing, China
| | | | | | | |
Collapse
|
31
|
Kim H, Song IK, Joo CK. Keratectasia after Laser in situ Keratomileusis. Ophthalmologica 2005; 220:58-64. [PMID: 16374050 DOI: 10.1159/000089276] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2004] [Accepted: 11/25/2004] [Indexed: 11/19/2022]
Abstract
PURPOSE To describe the morphological features of a prominent ectasia of the cornea after laser in situ keratomileusis (LASIK). METHODS The morphology of the ectatic corneas was examined using corneal topography, light microscopy and transmission electron microscopy in 2 cases who underwent penetrating keratoplasty due to poor visual acuity induced by progressive corneal ectasia after LASIK. RESULTS On topographic examination, the apex of the corneal surface was observed within the central 3-mm zone, and the smallest thickness was 0.116 and 0.271 mm in each case. On histological examination, the epithelial layer became thinner and detached easily. Bowman's membrane was broken down and folded. An irregular arrangement of the stromal lamellae with fibroblastic keratocytes was found. The fulled fiber cell, a transformed epithelial cell, was visible in a plane on Bowman's layer in the central region. In contrast, the corneal endothelium was intact, and no abnormality was found in both cases. CONCLUSION On morphological examination of 2 cases with corneal ectasia, a forward protrusion of both the anterior and posterior corneal surfaces occurred, and epithelial detachment, Bowman's membrane breakage and folding and irregular lamellae were found. The 2 cases had greatly thinned and protruding corneas, yet there was no abnormality in the corneal endothelium.
Collapse
Affiliation(s)
- Hyojin Kim
- Department of Ophthalmology and Visual Science, College of Medicine, Catholic University of Korea, Seoul, Korea
| | | | | |
Collapse
|
32
|
Alió JL, Artola A, Belda JI, Perez-Santonja JJ, Muñoz G, Javaloy J, Rodríguez-Prats JL, Galal A. LASIK in Patients with Rheumatic Diseases. Ophthalmology 2005; 112:1948-54. [PMID: 16168484 DOI: 10.1016/j.ophtha.2005.06.022] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2005] [Accepted: 06/04/2005] [Indexed: 11/25/2022] Open
Abstract
PURPOSE To investigate the safety of LASIK in patients with a known history of controlled rheumatic diseases. DESIGN Retrospective consecutive observational clinical study. PARTICIPANTS Forty-two eyes (22 patients) known to have had a history of rheumatic diseases underwent LASIK. All patients had a history of controlled rheumatic diseases, including rheumatoid arthritis, systemic lupus erythematosus, dermatomyositis, scleroderma, ankylosing spondylitis, psoriatic arthritis, inflammatory bowel disease, arthritis, or Behçet's disease. METHODS Assessments were made preoperatively and at 1, 3, and 6 months postoperatively and included visual acuity (VA), refraction, keratometric readings, slit-lamp biomicroscopy, and corneal topography. All the patients underwent LASIK. Postoperative treatment included a topical steroid-antibiotic combination. MAIN OUTCOME MEASURES Visual acuity, refraction, keratometric readings, and slit-lamp biomicroscopy findings at 1, 3, and 6 months postoperatively. RESULTS LASIK was performed uneventfully on all patients. The mean pre-LASIK spherical equivalent (SE) was -5.39+/-2.25, and the sixth month postoperative SE was -0.15+/-0.38 diopters (D) (P<0.001). Uncorrected VA 6 months after the LASIK procedure was 20/25. Enhancement procedures were performed in 6 of 42 eyes (14.3%) at variable times after the primary procedure. Postoperative follow-up showed development of a moderate degree of dry eye syndrome in 4 eyes (9.5%). Corneal haze, melting, flap, or interface complications were not observed in any of the study eyes. CONCLUSIONS In this small series, we found good outcomes when correcting refractive errors using LASIK in selected patients with controlled rheumatic diseases. In this series, a favorable postoperative visual outcome was obtained with no operative or postoperative vision-threatening complications.
Collapse
Affiliation(s)
- Jorge L Alió
- Refractive Surgery and Cornea Department, Instituto Oftalmológico de Alicante Vissum Corporation, and Medical School, Miguel Hernández University, Alicante, Spain.
| | | | | | | | | | | | | | | |
Collapse
|
33
|
Abstract
PURPOSE To determine if LASIK using a 130-microm microkeratome head (thin-flap LASIK) is as visually effective and safe as when using a 160-microm head. METHODS A study was performed comparing postoperative day 1 uncorrected visual acuity (UCVA) and flap complications in eyes undergoing myopic LASIK with a 130-microm head versus a 160-microm head using the BD K-3000 microkeratome (BD Ophthalmic Systems, Waltham, Mass). RESULTS The mean preoperative myopia in the 155 eyes of 80 patients in the 130-microm head group was -5.00+/-2.53 diopters (D) compared to -3.78+/-1.73 D in the 279 eyes of 148 patients in the 160-microm head group. The groups were otherwise similar in terms of age, preoperative cylinder, and best spectacle-corrected visual acuity. The geometric mean postoperative day 1 UCVA was 20/25 in the 130-microm head group compared to 20/26 in the 160-microm head group. The only flap complication in the series was a single partial flap in the 160-microm head group. CONCLUSIONS LASIK with a 130-microm head (thin-flap LASIK) is as visually effective and safe as when using a 160-microm head with the BD K-3000 microkeratome.
Collapse
Affiliation(s)
- Paul J Dougherty
- Dougherty Laser Vision and Jules Stein Eye Institute, David Geffen School of Medicine at UCLA, Los Angeles, Calif, USA.
| |
Collapse
|
34
|
Hiatt JA, Wachler BSB, Grant C. Reversal of laser in situ keratomileusis–induced ectasia with intraocular pressure reduction. J Cataract Refract Surg 2005; 31:1652-5. [PMID: 16129306 DOI: 10.1016/j.jcrs.2005.02.031] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/11/2005] [Indexed: 11/28/2022]
Abstract
A 40 year-old woman had laser in situ keratomileusis for --7.75 --0.75 x 20 in the right eye. Preoperative examinations, including topography, pachymetry, and intraocular pressures (IOPs), were normal, and best spectacle-corrected visual acuity (BSCVA) was 20/20 in each eye. By 4 months postoperatively, the uncorrected visual acuity and BSCVA in the right eye had decreased to 20/40. Corneal topography of that eye was consistent with ectasia. One drop per day of timolol 0.5% (Timoptic XE) was prescribed. Five months postoperatively, the IOP had decreased and BSCVA and topography had improved. At 11 months, BSCVA returned to 20/20 and corneal topography normalized. Topographic difference maps were used to monitor corneal shape changes. In this case, early reduction in IOP completely reversed the ectasia.
Collapse
|
35
|
Budo C, Bartels MC, van Rij G. Implantation of Artisan Toric Phakic Intraocular Lenses for the Correction of Astigmatism and Spherical Errors in Patients With Keratoconus. J Refract Surg 2005; 21:218-22. [PMID: 15977878 DOI: 10.3928/1081-597x-20050501-04] [Citation(s) in RCA: 59] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the correction of astigmatism and spherical ametropia in patients with keratoconus through implantation of an Artisan toric phakic intraocular lens (PIOL) (Ophtec, Groningen, The Netherlands). METHODS Artisan toric PIOLs were implanted uneventfully in both eyes of three patients with keratoconus with clear central corneas and contact lens intolerance. RESULTS Best spectacle-corrected subjective visual acuity after lens implantation was unchanged in one eye and improved in five eyes. Spherical equivalent refraction was significantly reduced in all eyes (P=.03). The safety index was 1.49. CONCLUSIONS The implantation of an Artisan toric PIOL may be an alternative for treating astigmatism and myopia in contact lens intolerant patients with keratoconus with clear central corneas. Especially in patients with associated myopia, this procedure is worth considering before planning a penetrating keratoplasty.
Collapse
Affiliation(s)
- Camille Budo
- Department of Ophthalmology, Sint Truiden, Belgium
| | | | | |
Collapse
|
36
|
Vinciguerra P, Munoz MIT, Camesasca FI, Grizzi F, Roberts C. Long-term follow-up of ultrathin corneas after surface retreatment with phototherapeutic keratectomy. J Cataract Refract Surg 2005; 31:82-7. [PMID: 15721699 DOI: 10.1016/j.jcrs.2004.10.039] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/12/2004] [Indexed: 11/29/2022]
Abstract
PURPOSE To evaluate visual acuity and long-term stability after phototherapeutic keratectomy (PTK) in patients with corneal thickness less than 400 microm and cornea-related vision problems. SETTING Department of Ophthalmology, Istituto Clinico Humanitas, Rozzano-Milan, Italy. METHODS This retrospective study comprised 48 eyes that had PTK for complications after photorefractive keratectomy that removed more than 200 microm of tissue. Phototherapeutic keratectomy was performed with the Nidek EC-5000 excimer laser with 10 Hz frequency, intraoperative topography, and masking fluid over an ablation diameter of 10.0 mm. The follow-up was 5 years. The mean preoperative best spectacle-corrected visual acuity (BSCVA) was 0.2 +/- 0.09 (SD) with -2.53 +/- 2.34 diopters (D), and the mean pachymetry was 390 +/- 38 microm. The efficacy parameters were pachymetry and visual acuity at 1 year and the stability parameters, optical refraction, corneal curvature (calculated as the mean curvature over the entire 3.0 mm and 5.0 mm central zones), and pachymetry from 1 to 5 years. RESULTS At 1 year, the mean BSCVA was 0.6 +/- 0.72 with -2.15 +/- 1.67 D and the mean pachymetry, 341 +/- 40 microm. At 5 years, the mean BSCVA was 0.7 +/- 0.15 with -2.33 +/- 1.12 D and the mean pachymetry, 339 +/- 48 microm. In all patients, there was an improvement of 4 or more Snellen lines. Statistical evaluation of refraction and corneal curvature values at 1 and 5 years indicated no statistically significant differences. CONCLUSIONS After PTK in eyes with ultrathin corneas, there was significant improvement in BSCVA and long-term stability of the optical refraction, corneal curvature, and pachymetry. In selected cases, 10.0 mm ablation zone PTK may be an alternative to penetrating keratoplasty, offering long-term corneal stability.
Collapse
Affiliation(s)
- Paolo Vinciguerra
- Department of Ophthalmology, Istituto Clinico Humanitas, Rozzano-Milan, Italy.
| | | | | | | | | |
Collapse
|
37
|
Kamiya K, Miyata K, Tokunaga T, Kiuchi T, Hiraoka T, Oshika T. Structural analysis of the cornea using scanning-slit corneal topography in eyes undergoing excimer laser refractive surgery. Cornea 2005; 23:S59-64. [PMID: 15448482 DOI: 10.1097/01.ico.0000136673.35530.e3] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE To review the time course of corneal anteroposterior shift and refractive stability after myopic excimer laser keratorefractive surgery. METHODS We examined 65 eyes undergoing photorefractive keratectomy (PRK) and 45 eyes undergoing laser in situ keratomileusis (LASIK). Corneal elevation maps and pachymetry were obtained by scanning-slit corneal topography before; 1 week; and 1, 3, 6, and 12 months after surgery. RESULTS Both PRK and LASIK induced significant forward shifts of the cornea. Corneal forward shift was progressive up to 6 months after PRK, but no progression was seen after LASIK. Progressive thinning and expansion of the cornea were not observed after either procedure. The amount of corneal forward shift showed a significant negative correlation with preoperative corneal thickness (r = -0.586; P < 0.01) and a significant positive correlation with the amount of myopic correction (r = 0.504; P < 0.01). A significant correlation was found between the amount of forward shift and the degree of myopic regression after surgery (r = -0.347; P < 0.05). CONCLUSION Myopic PRK and LASIK induce significant forward shifts of the cornea, which are not true corneal ectasia. Eyes with thinner corneas and higher myopia requiring greater ablation are more predisposed to anterior protrusion of the cornea. Corneal forward shift was progressive up to 6 months after PRK but not progressive after LASIK. Forward shift of the cornea can be one of the factors responsible for myopic regression after surgery.
Collapse
Affiliation(s)
- Kazutaka Kamiya
- Department of Ophthalmology, University of Tokyo School of Medicine, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.
| | | | | | | | | | | |
Collapse
|
38
|
Sanchis-Gimeno JA, Lleó-Pérez A, Alonso L, Rahhal MS, Martínez-Soriano F. Reduced Corneal Thickness Values in Postmenopausal Women With Dry Eye. Cornea 2005; 24:39-44. [PMID: 15604865 DOI: 10.1097/01.ico.0000138836.45070.0f] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE To study and compare the corneal thickness values of postmenopausal women with dry eye and postmenopausal women without dry eye. METHODS The corneal thickness value of 30 postmenopausal women with dry eye (dry eye group; aged 52 to 55 years) and 32 postmenopausal women without dry eye (normal group; aged 51 to 55 years) was analyzed with the Orbscan Topography System II. Each woman underwent a tear breakup test, the Schirmer test, fluorescein staining of the cornea, and an analysis of the meibomian gland by slit lamp before corneal thickness measurement. The statistical analysis was performed by means of the unpaired Student t test. RESULTS The mean corneal thickness value was significantly decreased in postmenopausal women with dry eye (P < 0.001 at each corneal location). The central cornea had the thinnest mean values in dry eyes and normal eyes (533.10 +/- 4.74 microm and 547.63 +/- 15.11 microm, respectively), whereas superonasal cornea had thicker mean values in both groups (632.43 +/- 6.11 microm and 648.78 +/- 14.98 microm in dry eye and normal eyes, respectively). CONCLUSIONS Postmenopausal women with dry eye have lower corneal thickness values than postmenopausal women without dry eye. Special care must be taken with these reduced corneal thickness values when selecting postmenopausal women for surgery involving corneal photoablation.
Collapse
Affiliation(s)
- Juan A Sanchis-Gimeno
- Department of Anatomy and Human Embryology, Faculty of Medicine, University of Valencia, Valencia, Spain.
| | | | | | | | | |
Collapse
|
39
|
Rao SK, Srinivasan B, Sitalakshmi G, Padmanabhan P. Photorefractive keratectomy versus laser in situ keratomileusis to prevent keratectasia after corneal ablation. J Cataract Refract Surg 2004; 30:2623-8. [PMID: 15617936 DOI: 10.1016/j.jcrs.2004.09.037] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/25/2004] [Indexed: 10/26/2022]
Abstract
A 27-year-old man had excimer photoastigmatic keratectomy in the right eye and laser in situ keratomileusis in the left eye for the treatment of equivalent myopia. Preoperative slitlamp examination did not reveal evidence of keratoconus, central corneal pachymetry was 485 microm in the right eye and 500 microm in the left eye, and corneal topography revealed asymmetric bow-tie astigmatism with inferior steepening in the right eye and a small area of inferior steepening in the left eye. Twenty-two months after surgery, the patient complained of poor vision in the left eye. Slitlamp examination of the left eye revealed central corneal thinning and protrusion, with a Fleischer ring within the flap. Corneal topographic evaluation revealed a stable map in the right eye and central corneal steepening indicative of keratectasia in the left eye.
Collapse
|
40
|
Pokroy R, Levinger S, Hirsh A. Single Intacs segment for post-laser in situ keratomileusis keratectasia. J Cataract Refract Surg 2004; 30:1685-95. [PMID: 15313291 DOI: 10.1016/j.jcrs.2004.02.050] [Citation(s) in RCA: 54] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/10/2003] [Indexed: 11/29/2022]
Abstract
PURPOSE To describe the visual outcome of implantation of a single Intacs segment (Addition Technology Inc.) in eyes with keratectasia after myopic laser in situ keratomileusis (LASIK). SETTING Private refractive surgery center, Jerusalem, Israel. METHODS This retrospective, noncomparative, interventional, consecutive, small case series studied 5 eyes of 5 patients with post-LASIK keratectasia from 3 refractive laser centers treated by Intacs implantation. Before and 9 months after Intacs implantation, the uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest refraction, keratometry, videokeratography, inferior-superior asymmetry, and patient questionnaires about visual function were assessed. RESULTS Intacs implantation was performed 17 to 32 months post LASIK with no intraoperative complications and no loss of visual acuity. After implantation, the UCVA improved 8, 4, 3, 0.5, and 5 lines and the BSCVA, 2, 2.5, 1, 0.5, and 2 lines. The mean manifest refraction spherical equivalent improved from -1.60 diopters (D) +/- 1.67 (SD) to -0.80 +/- 1.05 D. The mean manifest astigmatic correction decreased from -3.9 +/- 2.96 to -2.46 +/- 2.77 D. Corneal topography showed improved inferior steepening and less irregular astigmatism. The mean inferior-superior asymmetry improved from 7.88 +/- 4.59 to 2.46 +/- 2.77 D. Self-reported visual symptoms improved significantly in Cases 1, 2, and 5 and slightly in Cases 3 and 4. CONCLUSIONS Implantation of a single Intacs segment inferiorly appeared to improve progressive myopia and regular and irregular astigmatism in eyes with corneal ectasia after LASIK. With further study, this technique may prove to be an effective, relatively noninvasive approach.
Collapse
|
41
|
Abstract
PURPOSE To evaluate the prevalence of different topographic patterns in refractive surgery candidates and to estimate the extent of candidate rejection based on topography alone. METHODS We performed a retrospective evaluation of videokeratographies of previously unoperated refractive surgery candidates. The defined topographic patterns of their corneas and the indices computed by the videokeratographer software were registered. The data were evaluated by SPSS/PC statistical software. RESULTS One hundred candidate electronic topography records were evaluated. The candidates included 41 women and 59 men whose average age was 32 years (range 17.5-63.5). Their topographic patterns were: spherical (36/200 evaluated eyes), spherocylindrical (60), upper steep (32), lower steep (43), irregular astigmatism (9), decentered (3), suspected keratoconus (11), and probable keratoconus (6 eyes). Rejection from undergoing the procedure was based on topography alone in 27 of the 200 eyes. It was difficult to decide what to do with the 43 eyes with a lower steep pattern, and they were eventually rejected. Of the nine software-calculated indices, only one, "keratoconus index," could distinguish between the spherocylindrical and the lower steep patterns. CONCLUSIONS More than one-half of corneal topographies of refractive surgery candidates did not comply with the assumed "normal" spherical or spherocylindrical patterns. The possible continuum of keratoconus-suspected keratoconus-lower steep pattern raises the question of where to draw the line between reasonable and risky when considering corneal refractive surgery.
Collapse
Affiliation(s)
- David Varssano
- Department of Ophthalmology, Tel Aviv Medical Center, Tel Aviv University, Israel.
| | | | | |
Collapse
|
42
|
Kim JK, Kim SS, Lee HK, Lee IS, Seong GJ, Kim EK, Han SH. Laser in situ keratomileusis versus laser-assisted subepithelial keratectomy for the correction of high myopia. J Cataract Refract Surg 2004; 30:1405-11. [PMID: 15210215 DOI: 10.1016/j.jcrs.2003.12.053] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/05/2003] [Indexed: 11/19/2022]
Abstract
PURPOSE To compare the visual and refractive outcomes of laser in situ keratomileusis (LASIK) and laser-assisted subepithelial keratectomy (LASEK) in the treatment of high myopia. SETTING Institute of Vision Research, Department of Ophthalmology, College of Medicine, Yonsei University, and Balgeunsesang Ophthalmology Clinic, Seoul, South Korea. METHODS Four hundred seventy eyes of 240 patients with manifest refraction spherical components greater than -6.00 diopters (D) were assigned to 2 groups: 324 eyes (167 patients) were treated with LASIK and 146 eyes (73 patients), with LASEK. Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), remaining refractive error, corneal haze, and complications were followed in both groups for 12 months. RESULTS At 12 months, the mean spherical equivalent (SE) was within +/-0.50 D of emmetropia in 205 eyes (63.3%) in the LASIK group and 81 eyes (55.5%) in the LASEK group and within +/-1.00 D in 261 eyes (80.6%) and 104 eyes (71.2%), respectively. The UCVA was 20/25 or better in 269 LASIK eyes (83.0%) and 111 LASEK eyes (76.0%). There was more than a 1-line loss of BSCVA in 4 LASIK eyes (1.2%) and 21 LASEK eyes (14.3%). The between-group differences in SE, magnitude of cylinder, UCVA, and haze were statistically significant (P<.05). CONCLUSIONS Both LASIK and LASEK were safe and effectively treated eyes with high myopia. Laser in situ keratomileusis provided superior results in visual predictability and corneal opacity.
Collapse
Affiliation(s)
- Jin Kook Kim
- Balgensesang Ophthalmology Clinic, Institute of Vision Research, Department of Ophthalmology, College of Medicine, Yonsei University, Seoul, South Korea
| | | | | | | | | | | | | |
Collapse
|
43
|
Twa MD, Nichols JJ, Joslin CE, Kollbaum PS, Edrington TB, Bullimore MA, Mitchell GL, Cruickshanks KJ, Schanzlin DJ. Characteristics of Corneal Ectasia After LASIK for Myopia. Cornea 2004; 23:447-57. [PMID: 15220728 DOI: 10.1097/01.ico.0000122702.49054.12] [Citation(s) in RCA: 79] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE There are numerous reports of corneal ectasia after laser in situ keratomileusis (LASIK) for myopia without a consistent definition of this condition or a definitive etiology. We conducted a retrospective analysis of published case reports to describe common characteristics of this postoperative event and compared them with findings from a group of successful LASIK patients. METHODS A MEDLINE search for "LASIK" and "ectasia" yielded 21 relevant articles published before May 2003 (n = 86 eyes, 59 patients). A comparison group (n = 103 eyes, 63 patients) was selected from a clinic-based sample of successful LASIK patients with 12 months of follow-up after treatment. Descriptive statistics are reported as median and interquartile range. Comparisons were performed using the Wilcoxon rank sum, Wilcoxon signed rank, and chi-square tests. RESULTS Time to diagnosis of ectasia after LASIK was 13 months (6 to 20 months). Residual myopia in the ectasia group was -3.69 D (-6.00 to -2.13 D) and was significantly greater than the comparison group, -0.38 D (-0.75 to 0.00 D), P < 0.001. After surgery, eyes with ectasia had increased corneal toricity 2.87 D (2.00 to 4.9 D) with increased oblique astigmatism 1.3 D (0.23 to 2.89 D) relative to eyes in the comparison group 0.00 D (0.00 to 0.08 D), and a loss of 2 lines (-0.5 to -6 lines) of best spectacle-corrected visual acuity (all P < 0.001). Thirty-five percent of reported cases resulted in subsequent corneal transplantation. CONCLUSIONS Preoperative characteristics of corneal ectasia include worse visual acuity, less corneal thickness, greater residual myopia, and greater corneal toricity than nonectatic eyes. Treatment factors associated with corneal ectasia after LASIK are greater stromal ablation and less residual stromal bed thickness. Postoperative characteristics of corneal ectasia are myopic refractive error with increased astigmatism, worse spectacle-corrected visual acuity, increased corneal toricity with topographic abnormality, and progressive corneal thinning.
Collapse
Affiliation(s)
- Michael D Twa
- College of Optometry, Ohio State University, Columbus, 43210-1240, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
44
|
Twa MD, Kash RL, Costello M, Schanzlin DJ. Morphologic Characteristics of Lamellar Channel Deposits in the Human Eye. Cornea 2004; 23:412-20. [PMID: 15097142 DOI: 10.1097/00003226-200405000-00021] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To report the histologic characteristics of lamellar channel deposits after polymethyl methacrylate intrastromal corneal ring segments in a human eye. METHODS A 34-year-old man previously diagnosed with keratoconus received photorefractive keratectomy in his left eye that exacerbated his corneal ectasia. To delay or possibly prevent corneal transplant, the patient elected to have intrastromal corneal segments implanted in the left eye. One year later the patient underwent corneal transplant. Before transplant, lamellar channel deposits were noted on clinical microscopic examination of the left eye. We performed histologic evaluation to assess changes to the patient's excised corneal tissue and to further characterize the observed lamellar channel deposits. RESULTS Lamellar channel deposits in humans are histologically similar to our previous descriptions of deposits in rabbits. These deposits primarily consist of intracellular lipid accumulations that stain positively with oil red O and filipin but not periodic acid Schiff reaction. Immunohistochemistry of cells located in the deposit region stained positively with vimentin, suggesting that these cells were keratocytes. Stains for cytokeratins 3 and 12 and for CD68 were both negative, indicating that epithelial cells and macrophages were not present in the deposit region. CONCLUSION Lamellar channel deposits are a common clinical finding after intrastromal corneal implants. This case provides further evidence to support our hypothesis that lamellar channel deposits in humans are a tissue response to corneal implants that consist of intracellular lipid accumulations. We use this case to propose a theoretical construct for the observation of stromal lipid accumulation in response to corneal injury.
Collapse
Affiliation(s)
- Michael D Twa
- College of Optometry, The Ohio State University, Columbus, OH 43210-1240, USA.
| | | | | | | |
Collapse
|
45
|
Miyata K, Tokunaga T, Nakahara M, Ohtani S, Nejima R, Kiuchi T, Kaji Y, Oshika T. Residual bed thickness and corneal forward shift after laser in situ keratomileusis. J Cataract Refract Surg 2004; 30:1067-72. [PMID: 15130645 DOI: 10.1016/j.jcrs.2003.09.046] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/29/2003] [Indexed: 10/26/2022]
Abstract
PURPOSE To prospectively assess the forward shift of the cornea after laser in situ keratomileusis (LASIK) in relation to the residual corneal bed thickness. SETTING Miyata Eye Hospital, Miyazaki, Japan. METHODS Laser in situ keratomileusis was performed in 164 eyes of 85 patients with a mean myopic refractive error of -5.6 diopters (D) +/- 2.8 (SD) (range -1.25 to -14.5 D). Corneal topography of the posterior corneal surface was obtained using a scanning-slit topography system before and 1 month after surgery. Similar measurements were performed in 20 eyes of 10 normal subjects at an interval of 1 month. The amount of anteroposterior movement of the posterior corneal surface was determined. Multiple regression analysis was used to assess the factors that affected the forward shift of the corneal back surface. RESULTS The mean residual corneal bed thickness after laser ablation was 388.0 +/- 35.9 microm (range 308 to 489 microm). After surgery, the posterior corneal surface showed a mean forward shift of 46.4 +/- 27.9 microm, which was significantly larger than the absolute difference of 2 measurements obtained in normal subjects, 2.6 +/- 5.7 microm (P<.0001, Student t test). Variables relevant to the forward shift of the corneal posterior surface were, in order of magnitude of influence, the amount of laser ablation (partial regression coefficient B = 0.736, P<.0001) and the preoperative corneal thickness (B = -0.198, P<.0001). The residual corneal bed thickness was not relevant to the forward shift of the cornea. CONCLUSIONS Even if a residual corneal bed of 300 microm or thicker is preserved, anterior bulging of the cornea after LASIK can occur. Eyes with thin corneas and high myopia requiring greater laser ablation are more predisposed to an anterior shift of the cornea.
Collapse
|
46
|
Randleman JB, Thompson KP, Staver PR. Wavefront Aberrations From Corneal Ectasia After Laser in situ Keratomileusis Demonstrated by InterWave Aberrometry. J Refract Surg 2004; 20:170-5. [PMID: 15072317 DOI: 10.3928/1081-597x-20040301-13] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To report a case of corneal ectasia after laser in situ keratomileusis (LASIK). The patient presented with minimal alterations in manifest refraction but had obvious distortions in the wavefront error of the eye, as demonstrated by InterWave aberrometry. METHODS Retrospective case report and literature review. RESULTS Three years following uneventful and initially successful LASIK and two subsequent enhancement procedures, a patient experienced a decrease in uncorrected and best spectacle-corrected visual acuity with only minor changes in manifest refraction and initially subtle changes on corneal topography. InterWave aberrometry showed a wavefront distortion consistent with progressive steepening of the anterior cornea, reflecting possible development of corneal ectasia. CONCLUSIONS InterWave aberrometry in conjunction with corneal topography was useful for early recognition of the development of corneal ectasia after LASIK.
Collapse
|
47
|
Kymionis GD, Aslanides IM, Siganos CS, Pallikaris IG. Intacs for early pellucid marginal degeneration. J Cataract Refract Surg 2004; 30:230-3. [PMID: 14967293 DOI: 10.1016/s0886-3350(03)00656-4] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/13/2003] [Indexed: 10/26/2022]
Abstract
A 42-year-old man had Intacs (Addition Technology Inc.) implantation for early pellucid marginal degeneration (PMD). Two Intacs segments (0.45 mm thickness) were inserted uneventfully in the fashion typically used for low myopia correction (nasal-temporal). Eleven months after the procedure, the uncorrected visual acuity was 20/200, compared with counting fingers preoperatively, while the best spectacle-corrected visual acuity improved to 20/25 from 20/50. Corneal topographic pattern also improved. Although the results are encouraging, concern still exists regarding the long-term effect of this approach for the management of patients with PMD.
Collapse
Affiliation(s)
- George D Kymionis
- Vardinoyannion Eye Institute of Crete, University of Crete, Heraklion, Crete, Greece.
| | | | | | | |
Collapse
|
48
|
Abstract
Eighty-five cases of post laser in situ keratomileusis ectasia were reviewed and analyzed. Cases of keratoconus or forme fruste keratoconus were eliminated; many remaining case reports lacked key information. The current literature is unable to define a specific residual corneal thickness or a range of preoperative corneal thickness that would put an eye at risk for developing ectasia. The most logical cause for eyes without preexisting pathology to develop ectasia is a postablation stromal thickness that is mechanically unstable; this "minimal" thickness is probably specific to each eye. The preoperative and postoperative corneal thickness, measured flap thickness, and microkeratome and laser parameters used in a given case are required to determine the range of residual corneal thickness that puts the eye at risk for developing ectasia. Other as yet undetermined factors may play a role in the development of this complication.
Collapse
Affiliation(s)
- Perry S Binder
- Gordon Binder Vision Institute, San Diego, CA 92112, USA.
| |
Collapse
|
49
|
Seitz B, Rozsíval P, Feuermannova A, Langenbucher A, Naumann GOH. Penetrating keratoplasty for iatrogenic keratoconus after repeat myopic laser in situ keratomileusis: Histologic findings and literature review. J Cataract Refract Surg 2003; 29:2217-24. [PMID: 14670435 DOI: 10.1016/s0886-3350(03)00406-1] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
We report a patient with a sufficiently thick cornea (593 microm) and no topographic signs of keratoconus preoperatively who developed iatrogenic keratoconus 2 months after repeat laser in situ keratomileusis (-4.00 -1.00 x 20) performed 5 months after the primary procedure (-10.50 -1.00 x 55). After penetrating keratoplasty, macrophotography showed severe multidirectional "macrostriae" of the stromal bed. On histologic evaluation, excessive thinning of the residual stromal bed to a minimum of 75 microm in the valleys and a maximum of 200 microm at the peaks of the macrostriae were documented. The flap thickness was 225 microm in the center. The thicker-than-intended flap (160 microm) is thought to be the cause of the severe complication of the LASIK procedure.
Collapse
Affiliation(s)
- Berthold Seitz
- Department of Ophthalmology, University of Erlangen-Nürnberg, Erlangen, Germany.
| | | | | | | | | |
Collapse
|
50
|
Wang JC, Hufnagel TJ, Buxton DF. Bilateral keratectasia after unilateral laser in situ keratomileusis: A retrospective diagnosis of ectatic corneal disorder. J Cataract Refract Surg 2003; 29:2015-8. [PMID: 14604728 DOI: 10.1016/j.jcrs.2003.08.006] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
We present a case of iatrogenic keratectasia in the left eye after laser in situ keratomileusis (LASIK) with 14 microm of stromal ablation. Preoperative evaluation did not show significant evidence of keratoconus or forme fruste keratoconus in either eye. Twenty months postoperatively, in addition to postoperative ectasia in the left eye, the right eye developed mild changes in manifest refraction and on corneal topography. A retrospective diagnosis of ectatic corneal disorder was made in a patient who had no obvious findings of corneal pathology prior to LASIK.
Collapse
Affiliation(s)
- Jim C Wang
- Kaiser Permanente Medical Center, Department of Ophthalmology, Fontana, California 92335, USA.
| | | | | |
Collapse
|