1
|
Bang SP, Sabesan R, Yoon G. Effects of long-term neural adaptation to habitual sspherical aberration on through-focus visual acuity in adults. Sci Rep 2024; 14:26842. [PMID: 39500753 PMCID: PMC11538307 DOI: 10.1038/s41598-024-75289-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2024] [Accepted: 10/03/2024] [Indexed: 11/08/2024] Open
Abstract
We investigated how long-term visual experience with habitual spherical aberration (SA) influences subjective depth of focus (DoF). Nine healthy cycloplegic eyes with habitual SAs of different signs and magnitudes were enrolled. An adaptive optics (AO) visual simulator was used to measure through-focus high-contrast visual acuity after correcting all monochromatic aberrations and imposing + 0.5 μm and - 0.5 μm SAs for a 6-mm pupil. The positive (n = 6) and negative (n = 3) habitual SA groups ranged from 0.17 to 0.8 μm and from - 1.2 to - 0.12 μm for a 6-mm pupil, respectively. Although all optical conditions were identical, and the subjective DoFs were expected to be the same for all participants, the DoFs of individuals differed between the positive and negative habitual SA groups. For the positive habitual SA group, the mean DoF with positive AO-induced SA (2.14 D) was larger than that with negative AO-induced SA (1.88 D); for the negative habitual SA group, a smaller DoF was measured with positive AO-induced SA (1.94 D) than that with negative AO-induced SA (2.14 D). Subjective DoF tended to be larger when the induced SA in terms of sign and magnitude was closer to the participant's habitual SA. Our findings suggest that neural adaptation to habitual SA compensated for optical blur at multiple object distances, perceptually expanding DoF. As a result, the outcomes of optical treatments for presbyopia may differ due to the neural compensation mechanism influenced by an individual's visual experience with their habitual optics.
Collapse
Affiliation(s)
- Seung Pil Bang
- Department of Ophthalmology, Keimyung University School of Medicine, Daegu, South Korea
- Department of Biomedical Engineering, University of Rochester, Rochester, NY, United States
| | - Ramkumar Sabesan
- Department of Ophthalmology, University of Washington School of Medicine, Seattle, WA, USA
| | - Geunyoung Yoon
- College of Optometry, University of Houston, Houston, TX, 77004, USA.
| |
Collapse
|
2
|
Jang HS, Lee KJ. Spherical Aberration Changes in Patients With Early Presbyopia Wearing Aspheric Multifocal Soft Contact Lenses in South Korea. Eye Contact Lens 2024; 50:475-481. [PMID: 39235124 DOI: 10.1097/icl.0000000000001120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/07/2024] [Indexed: 09/06/2024]
Abstract
OBJECTIVES The aim of this study was to evaluate the impact of wearing center-near (CN) and center-distance (CD) multifocal contact lenses (MFCLs) on spherical aberrations and visual acuity in patients with early presbyopia. METHODS Fifty participants with early presbyopia wore CN-MFCLs and CD-MFCLs for 1 week. The average corrected refractive power was -2.65±1.67 D. Spherical aberration was measured using an auto-refractor after 1 week of lens use. RESULTS No significant difference in overall visual acuity was observed when using either lens. Participants favored CD-MFCLs for distance vision and CN-MFCLs for near vision. This study highlighted variations in aberration and satisfaction based on age, refractive errors, and individual responses. Patients with positive spherical aberrations tended to benefit from CN-MFCLs, which improved both distance and near vision, although additional correction was required for clear distance vision. Patients with early presbyopia generally preferred CN-MFCLs when positive aberration was prevalent, whereas those with negative aberration reported greater satisfaction with distance vision when wearing CD-MFCLs. CONCLUSIONS This study confirmed that wearing MFCLs leads to changes in spherical aberration and visual acuity in patients with early presbyopia, particularly when positive aberration prevails. Future research should investigate these effects across different stages of presbyopia.
Collapse
Affiliation(s)
- Hyo-Seung Jang
- Department of Optometry, Eulji University, Seoul, Republic of Korea
| | | |
Collapse
|
3
|
Salgado RMPC, Torres PFAAS, Marinho AAP. Pupil versus 1st Purkinje capsulotomy centration with femtosecond laser: Long term outcomes with a sinusoidal trifocal lens. JOURNAL OF BIOPHOTONICS 2024; 17:e202300446. [PMID: 38414335 DOI: 10.1002/jbio.202300446] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/26/2023] [Revised: 12/01/2023] [Accepted: 01/28/2024] [Indexed: 02/29/2024]
Abstract
PURPOSE To assess the role of femtosecond laser-assisted capsulotomy centration in the long-term intraocular positioning of a multifocal intraocular lens. DESIGN Prospective comparative study. METHODS A total of 60 eyes of 30 patients underwent femtosecond laser-assisted Refractive Lens Exchange (RLE). For every patient, capsulotomy centration was randomly performed according to pupil centre (PC) in one eye and first Purkinje reflex (FPR) in the other. The intraocular lens (IOL) positioning, visual acuities, spherical equivalent, internal aberrometry and quality of vision were assessed and compared at 3 years' follow-up between groups (PC and FPR). RESULTS Intraocular lens positioning showed a statistically significant difference between groups, with a closer centration to the visual axis in the FPR patients (p < 0.001). Internal aberrometry showed higher values in the PC capsulotomy centration group (p < 0.01). CONCLUSIONS FPR centered capsulotomy is associated to a closer centration of the IOL to the visual axis.
Collapse
Affiliation(s)
- Ramiro M P C Salgado
- Departamento de Oftalmologia do Hospital da Arrábida, Hospital de Santo António, Centro Hospitalar e Universitário do Porto, Portugal
| | - Paulo F A A S Torres
- Departamento de Oftalmologia do Hospital da Prelada, Universidade do Porto, Portugal
| | - António A P Marinho
- Departamento de Oftalmologia do Hospital da Luz Arrábida, Universidade do Porto, Portugal
| |
Collapse
|
4
|
Molina R, Redondo B, Ortiz C, Vera J, Díaz JA, Jiménez R. Higher order aberrations according to spherical, and astigmatic refractive errors in children. Clin Exp Optom 2024:1-12. [PMID: 38561016 DOI: 10.1080/08164622.2024.2325632] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Accepted: 02/04/2024] [Indexed: 04/04/2024] Open
Abstract
CLINICAL RELEVANCE The results of this study present novel insights into the impact of spherical and astigmatic refractive errors on overall, corneal and internal aberrations and may provide a clear understanding of the emmetropisation process and the development of visual function. BACKGROUND This study aimed to assess the association between overall, corneal and internal higher-order aberrations and the spherical and astigmatic components (magnitude and angle) of refractive error in a large sample of children. METHODS A total of 311 children aged 7 - 8 years old were classified based on spherical equivalent refraction (myopic, emmetropic and hyperopic); magnitude of astigmatism (none, low and moderate); and angle of astigmatism (with-the-rule, against-the-rule and oblique). Refractive error and overall, corneal and internal higher-order aberrations were measured using the OPD-Scan III workstation. RESULTS Regarding spherical equivalent refraction, myopic eyes had greater root mean square (RMS) overall higher-order values, total spherical, tetrafoil and secondary astigmatism aberrations, and internal higher-order, total spherical and tetrafoil aberrations in comparison to emmetropic eyes. The magnitude of astigmatism was positively associated with all overall RMS aberrations and with internal higher order, coma, total coma, total spherical and tetrafoil aberrations. Eyes with with-the-rule astigmatism showed higher RMS values of coma and total coma compared to eyes with against-the-rule and oblique astigmatism. CONCLUSIONS Higher-order aberrations are dependent on the spherical as well as astigmatic components of refractive error. These findings enhance the current understanding of the emmetropisation process and visual function development.
Collapse
Affiliation(s)
- Rubén Molina
- Department of Optics, University of Granada, Granada, Spain
| | - Beatriz Redondo
- Department of Optics, University of Granada, Granada, Spain
- New England College of Optometry, Boston, Massachusetts
| | - Carolina Ortiz
- Department of Optics, University of Granada, Granada, Spain
| | - Jesús Vera
- Department of Optics, University of Granada, Granada, Spain
- New England College of Optometry, Boston, Massachusetts
| | - José A Díaz
- Department of Optics, University of Granada, Granada, Spain
| | | |
Collapse
|
5
|
Bang SP, Sabesan R, Yoon G. Effects of Neural Adaptation to Habitual Spherical Aberration on Depth of Focus. RESEARCH SQUARE 2024:rs.3.rs-3917931. [PMID: 38410431 PMCID: PMC10896392 DOI: 10.21203/rs.3.rs-3917931/v1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/28/2024]
Abstract
We investigated how long-term visual experience with habitual spherical aberration (SA) influences subjective depth of focus (DoF). Nine healthy cycloplegic eyes with habitual SAs of different signs and magnitudes were enrolled. An adaptive optics (AO) visual simulator was used to measure through-focus high-contrast visual acuity after correcting all monochromatic aberrations and imposing +0.5 μm and -0.5 μm SAs for a 6-mm pupil. The positive (n=6) and negative (n=3) SA groups ranged from 0.17 to 0.8 μm and from -1.2 to -0.12 μm for a 6-mm pupil, respectively. For the positive habitual SA group, the median DoF with positive AO-induced SA (2.18D) was larger than that with negative AO-induced SA (1.91D); for the negative habitual SA group, a smaller DoF was measured with positive AO-induced SA (1.81D) than that with negative AO-induced SA (2.09D). The difference in the DoF of individual participants between the induced positive and negative SA groups showed a quadratic relationship with the habitual SA. Subjective DoF tended to be larger when the induced SA in terms of the sign and magnitude was closer to the participant's habitual SA, suggesting the importance of considering the habitual SA when applying the extended DoF method using optical or surgical procedures.
Collapse
|
6
|
Soomro SR, Sager S, Paniagua-Diaz AM, Prieto PM, Artal P. Head-mounted adaptive optics visual simulator. BIOMEDICAL OPTICS EXPRESS 2024; 15:608-623. [PMID: 38404335 PMCID: PMC10890873 DOI: 10.1364/boe.506858] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 12/22/2023] [Accepted: 12/26/2023] [Indexed: 02/27/2024]
Abstract
Adaptive optics visual simulation is a powerful tool for vision testing and evaluation. However, the existing instruments either have fixed tabletop configurations or, being wearable, only offer the correction of defocus. This paper proposes a novel head-mounted adaptive optics visual simulator that can measure and modify complex ocular aberrations in real-time. The prototype is composed of two optical modules, one for the objective assessment of aberrations and the second for wavefront modulation, all of which are integrated into a wearable headset. The device incorporates a microdisplay for stimulus generation, a liquid crystal on silicon (LCoS) spatial light modulator for wavefront manipulation, and a Hartmann-Shack wavefront sensor. Miniature optical components and optical path folding structures, together with in-house 3D printed mounts and housing, were adapted to realize the compact size. The system was calibrated by characterizing and compensating the internal aberrations of the visual relay. The performance of the prototype was analyzed by evaluating the measurement and compensation of low-order and higher-order aberrations induced through trial lenses and phase masks in an artificial eye. The defocus curves for a simulated bifocal diffractive lens were evaluated in real eyes. The results show high accuracy while measuring and compensating for the induced defocus, astigmatism, and higher-order aberrations, whereas the MTF analysis shows post-correction resolution of up to 37.5 cycles/degree (VA 1.25). Moreover, the subjective test results show the defocus curves closely matched to a commercial desktop visual simulator.
Collapse
Affiliation(s)
- Shoaib R. Soomro
- Voptica S.L., Campus de Espinardo (Edificio Pleiades), 30100 Murcia, Spain
- Electronic Engineering Department, Mehran University of Engineering and Technology, Pakistan
| | - Santiago Sager
- Voptica S.L., Campus de Espinardo (Edificio Pleiades), 30100 Murcia, Spain
- Laboratorio de Óptica, Universidad de Murcia, Campus de Espinardo (Edificio 34), 30100 Murcia, Spain
| | - Alba M. Paniagua-Diaz
- Laboratorio de Óptica, Universidad de Murcia, Campus de Espinardo (Edificio 34), 30100 Murcia, Spain
| | - Pedro M. Prieto
- Laboratorio de Óptica, Universidad de Murcia, Campus de Espinardo (Edificio 34), 30100 Murcia, Spain
| | - Pablo Artal
- Laboratorio de Óptica, Universidad de Murcia, Campus de Espinardo (Edificio 34), 30100 Murcia, Spain
| |
Collapse
|
7
|
Fernandez-Alonso M, Finch AP, Love GD, Read JCA. Ocular accommodation and wavelength: The effect of longitudinal chromatic aberration on the stimulus-response curve. J Vis 2024; 24:11. [PMID: 38411958 PMCID: PMC10910436 DOI: 10.1167/jov.24.2.11] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2023] [Accepted: 01/06/2024] [Indexed: 02/28/2024] Open
Abstract
The longitudinal chromatic aberration (LCA) of the eye creates a chromatic blur on the retina that is an important cue for accommodation. Although this mechanism can work optimally in broadband illuminants such as daylight, it is not clear how the system responds to the narrowband illuminants used by many modern displays. Here, we measured pupil and accommodative responses as well as visual acuity under narrowband light-emitting diode (LED) illuminants of different peak wavelengths. Observers were able to accommodate under narrowband light and compensate for the LCA of the eye, with no difference in the variability of the steady-state accommodation response between narrowband and broadband illuminants. Intriguingly, our subjects compensated more fully for LCA at nearer distances. That is, the difference in accommodation to different wavelengths became larger when the object was placed nearer the observer, causing the slope of the accommodation response curve to become shallower for shorter wavelengths and steeper for longer ones. Within the accommodative range of observers, accommodative errors were small and visual acuity normal. When comparing between illuminants, when accommodation was accurate, visual acuity was worst for blue narrowband light. This cannot be due to the sparser spacing for S-cones, as our stimuli had equal luminance and thus activated LM-cones roughly equally. It is likely because ocular LCA changes more rapidly at shorter wavelength and so the finite spectral bandwidth of LEDs corresponds to a greater dioptric range at shorter wavelengths. This effect disappears for larger accommodative errors, due to the increased depth of focus of the eye.
Collapse
Affiliation(s)
- Maydel Fernandez-Alonso
- Biosciences Institute, Newcastle University, Newcastle Upon Tyne, UK
- Present address: Translational Sensory and Circadian Neuroscience Group, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | | | - Gordon D Love
- Department of Physics, Durham University, Durham, UK
- Department of Computer Sciences, Durham University, Durham, UK
- Present address: School of Computing, University of Leeds, Leeds, UK
| | - Jenny C A Read
- Biosciences Institute, Newcastle University, Newcastle Upon Tyne, UK
| |
Collapse
|
8
|
Leroux C, Ouadi S, Leahy C, Marc I, Fontvieille C, Bardin F. Absolute prediction of relative changes in contrast sensitivity with aberrations using a single metric of retinal image quality. BIOMEDICAL OPTICS EXPRESS 2023; 14:3203-3212. [PMID: 37497514 PMCID: PMC10368034 DOI: 10.1364/boe.487217] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 05/09/2023] [Accepted: 05/10/2023] [Indexed: 07/28/2023]
Abstract
Metrics of retinal image quality predict optimal refractive corrections and correlate with visual performance. To date, they do not predict absolutely the relative change in visual performance when aberrations change and therefore need to be a-posteriori rescaled to match relative measurements. Here we demonstrate that a recently proposed metric can be used to predict, in an absolute manner, changes in contrast sensitivity measurements with Sloan letters when aberrations change. Typical aberrations of young and healthy eyes (for a 6 mm pupil diameter) were numerically introduced, and we measured the resulting loss in contrast sensitivity of subjects looking through a 2 mm diameter pupil. Our results suggest that the metric can be used to corroborate measurements of visual performance in clinical practice, thereby potentially improving patient follow-ups.
Collapse
Affiliation(s)
- Charles Leroux
- Laboratoire MIPA, Université de Nîmes, Sites des Carmes, Nîmes, 30000, France
| | - Sarah Ouadi
- Laboratoire MIPA, Université de Nîmes, Sites des Carmes, Nîmes, 30000, France
| | - Conor Leahy
- Carl Zeiss Meditec, Inc., 5300 Central Parkway, Dublin, CA 94568, USA
| | - Isabelle Marc
- Euromov Digital Health in Motion, Univ Montpellier, IMT Mines Ales, Alès, France
| | | | - Fabrice Bardin
- Laboratoire MIPA, Université de Nîmes, Sites des Carmes, Nîmes, 30000, France
| |
Collapse
|
9
|
Chay IW, Lin ST, Lim EWL, Heng WJ, Bin Ismail MA, Tan MCL, Zhao PSB, Nah GKM, Ang BCH. Higher order aberrations and visual function in a young Asian population of high myopes. Heliyon 2023; 9:e14901. [PMID: 37151700 PMCID: PMC10161382 DOI: 10.1016/j.heliyon.2023.e14901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2022] [Revised: 03/11/2023] [Accepted: 03/21/2023] [Indexed: 05/09/2023] Open
Abstract
Purpose To examine the associations between higher order aberrations (HOAs), visual performance, demographics, and ocular characteristics in a young Asian population with high myopia. Methods This was a retrospective review of military pre-enlistees conducted between March 2014 to September 2018. Visual acuity and contrast sensitivity were tested under photopic, mesopic and simulated night conditions. Ocular, corneal and internal HOAs were measured with a Hartmann-Shack wavefront aberrometer (KR-1W, Topcon Co., Tokyo, Japan). Results 522 eyes of 263 consecutive subjects with severe high myopia (defined as spherical equivalent refraction [SER] ≤ -10.00D) in at least one eye, and high myopia (SER ≤ -6.00D) in the fellow eye, [mean (SD) SER -11.85 (2.03D)] were analysed. The mean (SD) age of subjects was 18.5 (1.6) years. Chinese eyes had significantly greater internal total HOA root-mean-square (RMS) compared to Malay eyes [mean difference (SD) 0.0246 (0.007) μm, p < 0.001). More negative SER was associated with greater ocular total HOA (p = 0.038), primary coma (p = 0.003) and tetrafoil (p = 0.025) RMS, as well as more positive ocular (p = 0.003) and internal primary spherical aberration (p = 0.009). Greater ocular total HOAs was associated with reduced visual acuity in simulated night conditions and low contrast, decreased contrast sensitivity under mesopic and simulated night conditions (all p < 0.05). Conclusions Greater HOAs were associated with Chinese ethnicity and more negative SER in a young Asian population with high myopia. Greater HOAs were associated with poorer visual performance in low luminance and reduced contrast conditions.
Collapse
Affiliation(s)
- Isaac W. Chay
- Vision Performance Centre, Military Medicine Institute, Singapore Armed Forces Medical Corps, Singapore
- National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore
| | - Sheng Tong Lin
- DSO National Laboratories, Defence Medical and Environmental Research Institute, Singapore
| | - Edmund WL. Lim
- Vision Performance Centre, Military Medicine Institute, Singapore Armed Forces Medical Corps, Singapore
| | - Wee Jin Heng
- National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore
| | | | | | - Paul SB. Zhao
- Department of Ophthalmology, National University Health System, Singapore
| | - Gerard KM. Nah
- Department of Ophthalmology, National University Health System, Singapore
- W Eye Clinic, Singapore
| | - Bryan CH. Ang
- Vision Performance Centre, Military Medicine Institute, Singapore Armed Forces Medical Corps, Singapore
- National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore
- Department of Ophthalmology, Woodlands Health Campus, Singapore
- Corresponding author. 11 Jln Tan Tock Seng, Singapore 308433.
| |
Collapse
|
10
|
Na JH, Lee SJ. Analysis of Changes in High-order Aberration and Contrast Sensitivity After Epiblepharon Surgery. Ophthalmic Plast Reconstr Surg 2023; 39:141-145. [PMID: 35943422 DOI: 10.1097/iop.0000000000002261] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To investigate changes in corneal anterior high-order aberration (HOA) and contrast sensitivity (CS) before and after epiblepharon surgery. METHODS A retrospective observational analysis of the degree of corneal erosion, HOAs and CS was conducted in the OD and OS, respectively, before and after epiblepharon surgery. The correlations between corneal erosion, HOAs, and CS were analyzed. RESULTS Forty-nine patients were included in the study. Among the anterior HOAs, total HOA, coma, and trefoil showed significant improvement after surgery ( P = 0.003, P = 0.009, and P = 0.018, respectively). In the CS test, there was a significant improvement in CS after surgery at 1.1 cycles per degree (cpd) under photopic conditions, regardless of glare. Preoperative correlation analysis between HOAs and corneal erosion showed a significant positive correlation with total HOA ( P = 0.001) and coma ( P = 0.001). Preoperative correlation analysis between CS and corneal erosion showed a significant negative correlation at 1.1 cpd with glare under photopic conditions ( P = 0.049). A negative correlation was also observed between CS under mesopic and photopic conditions and total HOA both before and after surgery. CONCLUSION Significant improvement in corneal anterior HOAs and CS at 1.1 cpd under photopic conditions was observed after epiblepharon surgery. Total HOA of anterior cornea showed a negative correlation with CS. A decrease in HOAs and recovery of corneal erosion after epiblepharon surgery will help improve CS.
Collapse
Affiliation(s)
- Jeong Ho Na
- Department of Ophthalmology, Haeundae Paik Hospital, Inje University College of Medicine, Busan, Korea
| | | |
Collapse
|
11
|
Kordek D, Voda P, Young LK, Kremlacek J. Effect of Dioptric Blur on Pattern-Reversal and Motion-Onset VEPs as Used in Clinical Research. Transl Vis Sci Technol 2022; 11:7. [PMID: 36472879 PMCID: PMC9733653 DOI: 10.1167/tvst.11.12.7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Purpose To describe the effect of dioptric blur on visual evoked potentials (VEPs) induced by motion onset (MO-VEPs). Methods The effect of dioptric blur up to 4 D on MO-VEPs was tested on 12 subjects using central, peripheral, and full-field stimulation with a low-contrast structure of concentric circles with spatial frequency <1 c/°. The results were compared to VEPs evoked by 15' and 60' checkerboard pattern-reversal (PR-VEPs). The relationship between peak time and interpeak amplitude of the dominant components was related to the level of dioptric blur using linear regression. Results The MO-VEPs did not show a significant peak prolongation (P > 0.28) or amplitude attenuation (P > 0.14) with the blur, whereas for the PR-VEPs we observed a significant decrease in amplitude (P < 0.001) and increase in peak time (P < 0.001) for both checkerboard sizes. Conclusions For MO-VEPs induced by radial motion of low contrast and low spatial frequency pattern, the change in retinal blur does not affect the peak time or the interpeak amplitude of the dominant N2 component. Translational Relevance The resistance to retinal blur that we demonstrated for MO-VEP provides a diagnostic opportunity to test the integrity of the visual system and reveal a retrobulbar impairment even in uncorrected refractive errors.
Collapse
Affiliation(s)
- David Kordek
- Department of Biophysics, Faculty of Medicine, Charles University, Hradec Kralove, Czech Republic
| | - Petr Voda
- Department of Biophysics, Faculty of Medicine, Charles University, Hradec Kralove, Czech Republic
| | - Laura K. Young
- Biosciences Institute, Newcastle University, Newcastle, UK
| | - Jan Kremlacek
- Department of Biophysics, Faculty of Medicine, Charles University, Hradec Kralove, Czech Republic
| |
Collapse
|
12
|
Marcos S, Artal P, Atchison DA, Hampson K, Legras R, Lundström L, Yoon G. Adaptive optics visual simulators: a review of recent optical designs and applications [Invited]. BIOMEDICAL OPTICS EXPRESS 2022; 13:6508-6532. [PMID: 36589577 PMCID: PMC9774875 DOI: 10.1364/boe.473458] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/18/2022] [Revised: 10/26/2022] [Accepted: 10/27/2022] [Indexed: 05/02/2023]
Abstract
In their pioneering work demonstrating measurement and full correction of the eye's optical aberrations, Liang, Williams and Miller, [JOSA A14, 2884 (1997)10.1364/JOSAA.14.002884] showed improvement in visual performance using adaptive optics (AO). Since then, AO visual simulators have been developed to explore the spatial limits to human vision and as platforms to test non-invasively optical corrections for presbyopia, myopia, or corneal irregularities. These applications have allowed new psychophysics bypassing the optics of the eye, ranging from studying the impact of the interactions of monochromatic and chromatic aberrations on vision to neural adaptation. Other applications address new paradigms of lens designs and corrections of ocular errors. The current paper describes a series of AO visual simulators developed in laboratories around the world, key applications, and current trends and challenges. As the field moves into its second quarter century, new available technologies and a solid reception by the clinical community promise a vigorous and expanding use of AO simulation in years to come.
Collapse
Affiliation(s)
- Susana Marcos
- Center for Visual Sciences; The Institute of Optics and Flaum Eye Institute, University of Rochester, New York 14642, USA
| | - Pablo Artal
- Laboratorio de Optica, Universidad de Murcia, Campus Universitario de Espinardo, 30100, Spain
| | - David A. Atchison
- Centre for Vision and Eye Research, Queensland University of Technology, Brisbane Q, 4059, Australia
| | - Karen Hampson
- Department of Optometry, University of Manchester, Manchester M13 9PL, UK
| | - Richard Legras
- LuMIn, CNRS, ENS Paris-Saclay, Université Paris-Saclay, CentraleSupelec, Université Paris-Saclay Orsay, 91400, France
| | - Linda Lundström
- KTH (Royal Institute of Technology), Stockholm, 10691, Sweden
| | - Geunyoung Yoon
- College of Optometry, University of Houston, Houston, 77004, USA
| |
Collapse
|
13
|
Arba Mosquera S. Visual acuity and blur: An extended depth-of-focus model. Eur J Ophthalmol 2022; 33:11206721221123883. [PMID: 36200136 DOI: 10.1177/11206721221123883] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
PURPOSE This article proposes a simple model that describes the quantitative relationship between visual acuity and defocus (as in defocus curves) in the presence of higher-order aberrations (HOA). METHODS The basis model for describing the relationship between visual acuity and blur was taken from Blendowske as a starting point to develop an extended model applicable to defocus curves. The basis of Blendowskes's data is extended by incorporating effects induced by HOA. Aberrometric refractive errors are transformed into a single blur quantity b, also termed dioptric distance, which serves as an input in both models. The possible influence of the axes of asymmetric aberrations and the pupil size is not included. RESULTS The extended model has been used to generate reference data for a bi-aspheric multifocal correction profile for presbyopia. It provides reference data similar to what has been reported in the literature for that particular profile. CONCLUSIONS The model proposed in this article can be used to determine depth-of-focus effects associated with the presence of HOA. The extended model seems to provide a valid description for defocus curves. Actual uncertainties in experimental data on unaided visual acuity, especially the frequent lack of information on pupil diameter, prevent meaningful numerical comparison and the refinement of both models. However, theoretical arguments are provided in support of the extended model.
Collapse
|
14
|
Leroux C, Fontvieille C, Leahy C, Marc I, Bardin F. Predicting the effects of defocus blur on contrast sensitivity with a model-based metric of retinal image quality. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2022; 39:1866-1873. [PMID: 36215559 DOI: 10.1364/josaa.464034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Accepted: 09/07/2022] [Indexed: 06/16/2023]
Abstract
We measure the effect of defocus blur on contrast sensitivity with Sloan letters in the 0.75-2.00 arc min range of letter gaps. We compare our results with the prediction of the Dalimier and Dainty model [J. Opt. Soc. Am. A25, 2078 (2008)JOAOD60740-323210.1364/JOSAA.25.002078] and propose a new metric of retinal image quality that we define as the model limit for very small letters. The contrast sensitivity is measured for computationally blurred Sloan letters (0, 0.25, and 0.50 diopters for a 3 mm pupil) of different sizes (20/40 to 20/15 visual acuity), and subjects look through a small (2 mm) diaphragm to limit the impact of their own aberration on measurements. Measurements and model predictions, which are normalized by the blur-free condition, weakly depend on letter size and are in good agreement with our metric of retinal image quality. Our metric relates two approaches of modeling visual performance: complete modeling of the optotype classification task and calculation of retinal image quality with a descriptive metric.
Collapse
|
15
|
Ishiguro N, Horiguchi H, Katagiri S, Shiba T, Nakano T. Correlation between higher-order aberration and photophobia after cataract surgery. PLoS One 2022; 17:e0274705. [PMID: 36107829 PMCID: PMC9477362 DOI: 10.1371/journal.pone.0274705] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2022] [Accepted: 09/01/2022] [Indexed: 11/19/2022] Open
Abstract
Cataract surgery impinges on the spatial properties and wavelength distribution of retinal images, which changes the degree of light-induced visual discomfort/photophobia. However, no study has analyzed the alteration in photophobia before and after cataract surgery or the association between retinal spatial property and photophobia. Here, we measured the higher-order aberrations (HOAs) of the entire eye and the subjective photophobia score. This study investigated 71 eyes in 71 patients who received conventional cataract surgery. Scaling of photophobia was based on the following grading system: when the patient is outdoor on a sunny day, score of 0 and 10 points were assigned to the absence of photophobia and the presence of severe photophobia prevents eye-opening, respectively. We decomposed wavefront errors using Zernike polynomials for a 3-mm pupil diameter and analyzed the association between photophobia scores and HOAs with Spearman’s rank sum correlation (rs). We classified patients into two groups: photophobia (PP) unconcerned included patients who selected 0 both preoperatively or postoperatively and PP concerned included the remaining patients. After cataract surgery, photophobia scores increased, remained unchanged (stable), and decreased in 3, 41, and 27 cases, respectively. In the stable group, 35 of 41 cases belonged to PP unconcerned. In PP concerned, there were significant correlations between photophobia score and postoperative root-mean-square values of total HOAs (rs = 0.52, p = 0.002), total coma (rs = 0.52, p = 0.002), total trefoil (rs = 0.47, p = 0.006), and third-order group (rs = 0.53, p = 0.002). In contrast, there was no significant correlation between photophobia scores and preoperative HOAs. Our results suggest that the spatial properties of retinal image modified by HOAs may affect the degree of photophobia. Scattering light due to cataracts could contribute to photophobia more than HOAs, which may mask the effect of HOAs for photophobia preoperatively.
Collapse
Affiliation(s)
- Naoko Ishiguro
- Department of Ophthalmology, The Jikei University School of Medicine, Tokyo, Japan
| | - Hiroshi Horiguchi
- Department of Ophthalmology, The Jikei University School of Medicine, Tokyo, Japan
- * E-mail:
| | - Satoshi Katagiri
- Department of Ophthalmology, The Jikei University School of Medicine, Tokyo, Japan
| | | | - Tadashi Nakano
- Department of Ophthalmology, The Jikei University School of Medicine, Tokyo, Japan
| |
Collapse
|
16
|
Zhao W, Zhao J, Han T, Li M, Wang J, Zhou X. Evaluation of Disk Halo Size and Identification of Correlated Factors in Myopic Adults. Front Med (Lausanne) 2022; 9:743543. [PMID: 35155490 PMCID: PMC8831374 DOI: 10.3389/fmed.2022.743543] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2021] [Accepted: 01/05/2022] [Indexed: 11/15/2022] Open
Abstract
This study aimed to evaluate glare source-induced disk halo size and assess its correlation with higher-order aberrations (HOAs), pupillometry findings, and contrast sensitivity in myopic adults (aged 23.8 ± 4.4 years). In this cross-sectional study, 150 eyes of 150 patients were assessed. All patients underwent routine ophthalmic examinations, wavefront aberrometry, halo size measurement, dynamic pupillometry, and contrast sensitivity tests. Spearman's correlation analysis and independent sample t-tests were performed for data analysis. The mean halo radius was 82.5 ± 21.8 and 236.7 ± 52.2 arc min at 5 and 1 cd/m2 luminance levels, respectively. The values were inversely correlated with internal spherical aberration (SA) (r = −0.175, p = 0.032 and r = −0.241, p = 0.003, respectively), but not correlated with spherical equivalent (SE, both p > 0.05). Positive correlations were observed between halo radius and pupil size, contraction amplitude, and dilation speed during pupillary light reflex. Halo radii at 5 and 1 cd/m2 luminance levels were not significantly correlated with the area under the log contrast sensitivity function (r = −0.093, p = 0.258 and r = −0.149, p = 0.069, respectively). The mean halo radius was not clinically different between myopic and healthy eyes at 5 cd/m2 luminance level and did not differ significantly between the high and low-to-moderate myopia at 5 and 1 cd/m2 luminance levels (all p > 0.05). According to a stepwise linear regression model, the internal SA had a negative effect on the halo radius under low photpic condition; the average pupil diameter, internal SA and corneal HOAs played a large role in determining the halo radius under mesopic condition.
Collapse
Affiliation(s)
- Wuxiao Zhao
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Jing Zhao
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Tian Han
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Meng Li
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Jifang Wang
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Xingtao Zhou
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
- *Correspondence: Xingtao Zhou
| |
Collapse
|
17
|
Du R, Fang L, Peng W, Yang R, Nie S, Xiao H, Gong J, Dai Y, Deng J. Wave front aberrations induced from biomechanical effects after customized myopic laser refractive surgery in finite element model. Int Ophthalmol 2021; 42:81-94. [PMID: 34392473 DOI: 10.1007/s10792-021-02003-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Accepted: 08/06/2021] [Indexed: 11/28/2022]
Abstract
PURPOSE A customized myopic refractive surgery was simulated by establishing a finite element model of the human eye, after which we studied the wave front aberrations induced by biomechanical effects and ablation profile after wave front-guided LASIK surgery. METHODS Thirty myopia patients (i.e., 60 eyes) without other eye diseases were selected. Their ages, preoperative spherical equivalent, astigmatism, and wave front aberration were then obtained, in addition to the mean spherical equivalent error range - 4 to - 8D. Afterward, wave front-guided customized LASIK surgery was simulated by establishing a finite element eye model, followed by the analysis of the wave front aberrations induced by the surface displacement from corneal biomechanical effects, as well as customized ablation profile. Finally, the preoperative and induced aberrations were statistically analyzed. RESULTS Comatic aberrations were the main wave front abnormality induced by biomechanical effects, and the wave front aberrations induced by the ablation profile mainly included coma and secondary coma, as well as sphere and secondary-sphere aberrations. Overall, the total high-order aberrations (tHOAs), total coma (C31), and sphere ([Formula: see text]) increased after wave front-guided customized LASIK surgery. According to our correlation analyses, coma, sphere, and tHOAs were significantly correlated with decentration. Additionally, the material parameters of ocular tissue were found to affect the postoperative wave front aberrations. When the material parameters of the sclera remained constant but those of cornea increased, the induced wave front aberrations were reduced. CONCLUSION All biomechanical effects of cornea and ablation profile had significant effects on postoperative wave front aberrations after customized LASIK refractive surgery; however, the effects of the ablation profile were more notorious. Additionally, the characteristics of biomechanical materials have influence on the clinical correction effect.
Collapse
Affiliation(s)
- Ruirui Du
- Nanchang Hangkong University, Nanchang, 330063, China
| | - Lihua Fang
- Key Laboratory of Nondestructive Test (Ministry of Education), Nanchang Hangkong University, Nanchang, 86-18170938193, 330063, China.
| | - Weijian Peng
- Nanchang Hangkong University, Nanchang, 330063, China
| | - Ruizhi Yang
- Nanchang Hangkong University, Nanchang, 330063, China
| | - Shifeng Nie
- Nanchang Hangkong University, Nanchang, 330063, China
| | - Huirong Xiao
- Nanchang Hangkong University, Nanchang, 330063, China
| | - Jiahui Gong
- Nanchang Hangkong University, Nanchang, 330063, China
| | - Yu Dai
- Nanchang Hangkong University, Nanchang, 330063, China
| | - Jiahao Deng
- Nanchang Hangkong University, Nanchang, 330063, China
| |
Collapse
|
18
|
Shneor E, Piñero DP, Doron R. Contrast sensitivity and higher-order aberrations in Keratoconus subjects. Sci Rep 2021; 11:12971. [PMID: 34155283 PMCID: PMC8217180 DOI: 10.1038/s41598-021-92396-5] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Accepted: 06/09/2021] [Indexed: 02/05/2023] Open
Abstract
This study analyzes the relationship between contrast-sensitivity and higher-order aberrations (HOA) in mild and subclinical-keratoconus in subjects with good visual-acuity (VA). Keratoconus group (including subclinical-keratoconus) and controls underwent autokeratometry, corneal-tomography, autorefraction and HOA measurement. Contrast-sensitivity was tested using a psychophysical two-alternative forced-choice Gabor patches in three blocks (6, 9, 12 cycles/deg). Controls were compared to the keratoconus group and to a keratoconus subgroup with VA of 0.00 LogMar group ("keratoconus-0.00VA"). Spearman correlation tested association between HOA and contrast-sensitivity. Twenty-two keratoconus subjects (38 eyes: 28 keratoconus, 10 subclinical-keratoconus, 20 keratoconus-0.00VA) and 35 controls were included. There was a significant difference between control and keratoconus, and between control and keratoconus-0.00VA, for keratometry, cylinder, thinnest and central corneal thickness (p < 0.001). Controls showed lower HOA and higher contrast-sensitivity for all spatial-frequencies (p < 0.001). Most HOA were negatively correlated with contrast-sensitivity for all spatial-frequencies for keratoconus group and for 9 and 12 cycles/deg for keratoconus-0.00VA. Keratoconus subjects with good VA showed reduction in contrast-sensitivity and increased HOAs compared to controls. HOA and contrast-sensitivity are inversely correlated in subjects with mild keratoconus despite good VA. This suggests that the main mechanism underlying the decreased vision quality in keratoconus is the increase of HOA.
Collapse
Affiliation(s)
- Einat Shneor
- Department of Optometry and Vision Science, Hadassah Academic College, Haniviim St. 37, 9101001, Jerusalem, Israel.
| | - David P Piñero
- Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain
| | - Ravid Doron
- Department of Optometry and Vision Science, Hadassah Academic College, Haniviim St. 37, 9101001, Jerusalem, Israel
| |
Collapse
|
19
|
Lombardo M, Lombardo G. New methods and techniques for sensing the wave aberrations of human eyes. Clin Exp Optom 2021; 92:176-86. [DOI: 10.1111/j.1444-0938.2009.00356.x] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022] Open
Affiliation(s)
- Marco Lombardo
- Vision Engineering, Reggio Calabria, Italy and CNR‐INFM LiCryL Laboratory, Department of Physics, University of Calabria, Rende (CS), Italy
E‐mail:
| | - Giuseppe Lombardo
- Vision Engineering, Reggio Calabria, Italy and CNR‐INFM LiCryL Laboratory, Department of Physics, University of Calabria, Rende (CS), Italy
E‐mail:
| |
Collapse
|
20
|
Atchison DA. Recent advances in measurement of monochromatic aberrations of human eyes. Clin Exp Optom 2021; 88:5-27. [PMID: 15658922 DOI: 10.1111/j.1444-0938.2005.tb06659.x] [Citation(s) in RCA: 49] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2004] [Revised: 11/18/2004] [Accepted: 11/27/2004] [Indexed: 11/29/2022] Open
Abstract
The field of aberrations of the human eye is moving rapidly, being driven by the desire to monitor and optimise vision following refractive surgery. It is important for ophthalmologists and optometrists to have an understanding of the magnitude of various aberrations and how these are likely to be affected by refractive surgery and other corrections. In this paper, I consider methods used to measure aberrations, the magnitude of aberrations in general populations and how these are affected by various factors (for example, age, refractive error, accommodation and refractive surgery) and how aberrations and their correction affect spatial visual performance.
Collapse
Affiliation(s)
- David A Atchison
- School of Optometry, Queensland University of Technology, Kelvin Grove, QLD 4059, Australia
| |
Collapse
|
21
|
Marcos S, Martinez-Enriquez E, Vinas M, de Castro A, Dorronsoro C, Bang SP, Yoon G, Artal P. Simulating Outcomes of Cataract Surgery: Important Advances in Ophthalmology. Annu Rev Biomed Eng 2021; 23:277-306. [PMID: 33848431 DOI: 10.1146/annurev-bioeng-082420-035827] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
As the human eye ages, the crystalline lens stiffens (presbyopia) and opacifies (cataract), requiring its replacement with an artificial lens [intraocular lens (IOL)]. Cataract surgery is the most frequently performed surgical procedure in the world. The increase in IOL designs has not been paralleled in practice by a sophistication in IOL selection methods, which rely on limited anatomical measurements of the eye and the surgeon's interpretation of the patient's needs and expectations. We propose that the future of IOL selection will be guided by 3D quantitative imaging of the crystalline lens to map lens opacities, anticipate IOL position, and develop fully customized eye models for ray-tracing-based IOL selection. Conversely, visual simulators (in which IOL designs are programmed in active elements) allow patients to experience prospective vision before surgery and to make more informed decisions about which IOL to choose. Quantitative imaging and optical and visual simulations of postsurgery outcomes will allow optimal treatments to be selected for a patient undergoing modern cataract surgery.
Collapse
Affiliation(s)
- Susana Marcos
- Instituto de Óptica "Daza de Valdés," Consejo Superior de Investigaciones Científicas (IO-CSIC), Madrid 28006, Spain;
| | - Eduardo Martinez-Enriquez
- Instituto de Óptica "Daza de Valdés," Consejo Superior de Investigaciones Científicas (IO-CSIC), Madrid 28006, Spain;
| | - Maria Vinas
- Instituto de Óptica "Daza de Valdés," Consejo Superior de Investigaciones Científicas (IO-CSIC), Madrid 28006, Spain;
| | - Alberto de Castro
- Instituto de Óptica "Daza de Valdés," Consejo Superior de Investigaciones Científicas (IO-CSIC), Madrid 28006, Spain;
| | - Carlos Dorronsoro
- Instituto de Óptica "Daza de Valdés," Consejo Superior de Investigaciones Científicas (IO-CSIC), Madrid 28006, Spain; .,2EyesVision, Madrid 28760, Spain
| | - Seung Pil Bang
- Flaum Eye Institute, The Institute of Optics, Center for Visual Science, Department of Biomedical Engineering, University of Rochester, Rochester, New York 14632, USA
| | - Geunyoung Yoon
- Flaum Eye Institute, The Institute of Optics, Center for Visual Science, Department of Biomedical Engineering, University of Rochester, Rochester, New York 14632, USA
| | - Pablo Artal
- Laboratorio de Óptica, Universidad de Murcia, Murcia 30100, Spain
| |
Collapse
|
22
|
Frings A, Hassan H, Allan BD. Pyramidal Aberrometry in Wavefront-Guided Myopic LASIK. J Refract Surg 2020; 36:442-448. [PMID: 32644166 DOI: 10.3928/1081597x-20200519-03] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2019] [Accepted: 05/19/2020] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate measurement repeatability and clinical results for pyramidal aberrometry in routine myopic wavefront-guided laser in situ keratomileusis (LASIK). METHODS Results from 265 consecutive eyes treated with myopic wavefront-guided LASIK using the Amaris 1050RS Excimer Laser and Peramis pyramidal aberrometer (SCHWIND eye-tech-solutions GmbH) were reviewed. Limits of repeatability were calculated for the aberrometric refraction spherical equivalent and higher order aberrations for the Peramis aberrometer using results from three consecutive scans acquired preoperatively and postoperatively for the first 100 eyes treated. RESULTS The 95% limits of repeatability for pyramidal aberrometric measurement were: 0.3 diopters (D) for sphere, 0.2 D for cylinder, and 0.1 D (dioptric equivalent) for 3rd and 4th order aberration indices. A total of 95% of eyes were within ±0.50 D of the manifest refraction spherical equivalent target postoperatively. Uncorrected distance visual acuity was 20/20 or better in 96% of 232 eyes with a plano refraction target outcome. A total of 97% of eyes had a refraction cylinder of 0.50 D or less. No eyes lost one or more line of corrected distance visual acuity. CONCLUSIONS These data demonstrate good measurement repeatability, safety, and efficacy for pyramidal aberrometry in routine myopic LASIK. [J Refract Surg. 2020;36(7):442-448.].
Collapse
|
23
|
Jinabhai AN. Customised aberration-controlling corrections for keratoconic patients using contact lenses. Clin Exp Optom 2019; 103:31-43. [PMID: 31264266 DOI: 10.1111/cxo.12937] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Revised: 05/20/2019] [Accepted: 05/23/2019] [Indexed: 12/12/2022] Open
Abstract
Technological advancements in the design of soft and scleral contact lenses have led to the development of customised, aberration-controlling corrections for patients with keratoconus. As the number of contact lens manufacturers producing wavefront-guided corrections continues to expand, clinical interest in this customisable technology is also increasing among both patients and practitioners. This review outlines key issues surrounding the measurement of ocular aberrations for patients with keratoconus, with a particular focus on the possible factors affecting the repeatability of Hartmann-Shack aberrometry measurements. This review also discusses and compares the relative successes of studies investigating the design and fitting of soft and scleral customised contact lenses for patients with keratoconus. A series of key limitations that should be considered before designing customised contact lens corrections is also described. Despite the challenges of producing and fitting customised lenses, improvements in visual performance and comfortable wearing times, as provided by these lenses, could help to reduce the rate of keratoplasty in keratoconic patients, thereby significantly reducing clinical issues related to corneal graft surgery. Furthermore, enhancements in optical correction, provided by customised lenses, could lead to increased independence, particularly among young adult keratoconic patients, therefore leading to improvements in quality of life.
Collapse
Affiliation(s)
- Amit Navin Jinabhai
- Division of Pharmacy and Optometry, School of Health Sciences, Faculty of Biology Medicine and Health, The University of Manchester, Manchester, UK
| |
Collapse
|
24
|
Ryan DS, Sia RK, Rabin J, Rivers BA, Stutzman RD, Pasternak JF, Eaddy JB, Logan LA, Bower KS. Contrast Sensitivity After Wavefront-Guided and Wavefront-Optimized PRK and LASIK for Myopia and Myopic Astigmatism. J Refract Surg 2018; 34:590-596. [PMID: 30199562 DOI: 10.3928/1081597x-20180716-01] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2018] [Accepted: 07/03/2018] [Indexed: 11/20/2022]
Abstract
PURPOSE To compare contrast sensitivity among participants undergoing wavefront-guided or wavefront-optimized photorefractive keratectomy (PRK) or LASIK for the treatment of myopia or myopic astigmatism 12 months after surgery. METHODS In a prospective, randomized clinical trial, 215 participants with myopia ranging from -0.50 to -7.25 diopters (D) and less than -3.50 D of manifest astigmatism electing to undergo either LASIK or PRK were randomized to receive wavefront-guided or wavefront-optimized treatment. Corrected Super Vision Test (Precision Vision, La Salle, IL) high contrast and small letter contrast sensitivity, uncorrected postoperative contrast sensitivity function, and uncorrected and corrected distance visual acuity were measured preoperatively and at 1, 3, 6, and 12 months postoperatively. RESULTS There was a significant difference within each of the four groups over time when measuring high contrast visual acuity (P < .001) and small letter contrast sensitivity (P < .001), with the most significant decrease occurring 1 month postoperatively. However, there were no significant differences when comparing the four groups for high contrast sensitivity (P = .22) or small letter contrast sensitivity (P = .06). The area under the logarithm of contrast sensitivity function did not differ significantly over time (P = .09) or between groups (P = .16). A pairwise comparison of preoperative to 12-month CDVA showed a significant improvement in all groups (P < .017). The change in CDVA was also significantly different between groups as determined by one-way analysis of variance (P = .003). CONCLUSIONS Wavefront-guided and wavefront-optimized PRK and LASIK procedures maintained high contrast, small letter contrast sensitivity, and contrast sensitivity function 12 months postoperatively. Although the recovery period for visual performance was longer for PRK versus LASIK, there was no significant difference in treatment type or treatment profile at 12 months postoperatively. [J Refract Surg. 2018;34(9):590-596.].
Collapse
|
25
|
|
26
|
Long-term visual outcomes of laser anterior ciliary excision. Am J Ophthalmol Case Rep 2018; 10:38-47. [PMID: 29780911 PMCID: PMC5956797 DOI: 10.1016/j.ajoc.2018.01.033] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2017] [Revised: 11/13/2017] [Accepted: 01/18/2018] [Indexed: 11/22/2022] Open
Abstract
Purpose To determine the long-term visual outcomes of six eyes of 3 patients up to 13 years following the Laser Anterior Ciliary Excision (LaserACE) procedure. Methods Three male patients of ages 59, 59, and 60 presented for evaluation at Storm Eye Institute, Medical University of South Carolina at 8, 10, and 13 years after the LaserACE procedure for presbyopia, respectively. All 3 patients had a history of laser vision correction (LVC) prior to LaserACE treatment. Visual performance was evaluated using ray-tracing aberrometry, specifically higher-order aberrations, visual Strehl of the optical transfer function (VSOTF), depth of focus (DoF), and effective range of focus (EROF). VSOTF was computed as a function of defocus using a through-focus curve. Subjective DoF was overlaid on the VSOTF through-focus curve to establish the best image quality metric threshold value for correlation between subjective and objective DoF. EROF was determined by measuring the difference in diopters between the near and distance DoF curves, at 50% of VSOTF. Results Distance-corrected visual acuity, distance-corrected intermediate visual acuity, and distance-corrected near visual acuity for all patients remained at 20/20 or better up to 13 years postoperatively. EROF averaged 1.56 ± 0.36 (D) for all eyes. Conclusions and Importance LaserACE provided improvement in near vision functionality in these LVC patients with long-term stability. The LaserACE procedure is not on the visual axis, therefore these patients could still receive correction to their hyperopic regression.
Collapse
|
27
|
de Gracia P, Hartwig A. Optimal orientation for angularly segmented multifocal corrections. Ophthalmic Physiol Opt 2017; 37:610-623. [DOI: 10.1111/opo.12402] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2017] [Accepted: 07/06/2017] [Indexed: 12/01/2022]
Affiliation(s)
- Pablo de Gracia
- Midwestern University; Chicago College of Optometry; Downers Grove IL USA
- Department of Neurobiology; Barrow Neurological Institute; St. Joseph's Hospital and Medical Center; Phoenix AZ USA
| | - Andreas Hartwig
- Hartwig Research Center UG (Haftungsbeschränkt); Heikendorf Schleswig-Holstein Germany
| |
Collapse
|
28
|
Feng L, Lin H, Chen Y, Wang J, Wang Y, Liao R, Zhou J, Hess RF. The effect of Lasik surgery on myopic anisometropes' sensory eye dominance. Sci Rep 2017; 7:3629. [PMID: 28620156 PMCID: PMC5472567 DOI: 10.1038/s41598-017-03553-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2016] [Accepted: 05/02/2017] [Indexed: 11/09/2022] Open
Abstract
Lasik is a common surgery for treating anisometropia. In this study, we asked a specific question: what’s the effect of Lasik surgery on anisometropes’ sensory eye dominance? Fifteen myopic anisometropes (mean age: 23 ± 6.9 years old; 6 females) participated in our experiment. We quantitatively measured participants’ sensory eye dominance before and after the Lasik surgery using a binocular phase combination paradigm. We found no significant change of sensory eye dominance within 16 weeks (measured between 8 to 96 days, for one or two repetitions) after the surgery (t(14) = −1.44, p = 0.17). A further following on eight patients showed that patients’ two eyes were much more balanced at 16 weeks or more (measured one or two times between 112 to 408 days) after the surgery (t(7) = −3.79, p = 0.007). Our results suggest that the benefit of Lasik surgery on anisometropes’ sensory eye dominance is not immediate, a long-term ‘adaptation’ period (16 weeks or more) is necessary to enable the surgery to be truly effective.
Collapse
Affiliation(s)
- Lixia Feng
- Department of Ophthalmology, First Affiliated Hospital, Anhui Medical University, Hefei, Anhui, P.R. China.
| | - Huimin Lin
- Department of Ophthalmology, First Affiliated Hospital, Anhui Medical University, Hefei, Anhui, P.R. China
| | - Yao Chen
- Department of Ophthalmology, First Affiliated Hospital, Anhui Medical University, Hefei, Anhui, P.R. China
| | - Jiafeng Wang
- Department of Ophthalmology, First Affiliated Hospital, Anhui Medical University, Hefei, Anhui, P.R. China
| | - Yonghua Wang
- School of Ophthalmology and Optometry and Eye hospital, Wenzhou Medical University, Wenzhou, Zhejiang, P.R. China.,State Key Laboratory of Ophthalmology, Optometry and Vision Science, Wenzhou Medical University, Wenzhou, Zhejiang, P.R. China
| | - Rongfeng Liao
- Department of Ophthalmology, First Affiliated Hospital, Anhui Medical University, Hefei, Anhui, P.R. China
| | - Jiawei Zhou
- School of Ophthalmology and Optometry and Eye hospital, Wenzhou Medical University, Wenzhou, Zhejiang, P.R. China. .,State Key Laboratory of Ophthalmology, Optometry and Vision Science, Wenzhou Medical University, Wenzhou, Zhejiang, P.R. China.
| | - Robert F Hess
- McGill Vision Research, Dept. Ophthalmology, McGill University, Montreal, PQ, Canada
| |
Collapse
|
29
|
Descemet stripping automated endothelial keratoplasty versus descemet membrane endothelial keratoplasty: a meta-analysis. Int Ophthalmol 2017; 38:897-905. [PMID: 28417337 DOI: 10.1007/s10792-017-0533-3] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2016] [Accepted: 04/10/2017] [Indexed: 01/11/2023]
Abstract
PURPOSE To evaluate the efficacy and safety of descemet stripping automated endothelial keratoplasty (DSAEK) compared with descemet membrane endothelial keratoplasty (DMEK). METHODS Databases including PubMed, EMBASE, and Cochrane Library were searched to find studies that compared DSAEK and DMEK outcomes. Efficacy parameters were the postoperative best-corrected visual acuity (BCVA) and spherical equivalent (SE). Safety parameters were postoperative endothelial cell loss (ECL), air injection (rebubbling), graft failure, graft rejection, and high intraocular pressure (IOP). Results from last visit were pooled for the analyses because the follow-up ranged from 3 to 24 months. RESULTS A total of 7 trials including 433 eyes were selected for this meta-analysis. BCVA was reported in all 7 studies, ECL% and rebubbling rate were reported in 6, and the remaining outcomes were reported in only 3 or 2 studies. Postoperative logMAR BCVA was significantly better for DMEK than that for DSAEK (P < 0.00001). More patients achieved the postoperative BCVA ≥ 20/25 and 20/20 in DMEK group than that in DSAEK (P > 0.001), whereas the proportion of patients whose postoperative BCVA ≥ 20/40 and the amount of SE did not differ statistically (P = 0.32 and P = 0.50, respectively). The DSAEK group has a significantly lower frequency of rebubbling than the DMEK group (P < 0.0001). The postoperative ECL%, graft failure, graft rejection, and high IOP were comparable between the 2 groups (all P values >0.05). CONCLUSIONS Our meta-analysis suggests that DMEK provided better visual outcomes with similar safety when compared to DSAEK. Given the limited sample size, further investigations are needed to validate these findings.
Collapse
|
30
|
Kang MK, Yoo YS, Chung SH. Comparison of Ocular Aberration and Clinical Outcome between Different Aspheric Intraocular Lenses in Both Eyes. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2017. [DOI: 10.3341/jkos.2017.58.5.530] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Min Ku Kang
- Department of Ophthalmology and Visual Science, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Young Sik Yoo
- Department of Ophthalmology and Visual Science, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - So Hyang Chung
- Department of Ophthalmology and Visual Science, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| |
Collapse
|
31
|
Shin JS, Hwang KY. Changes in Higher-order Aberrations after Superior-incision Cataract Surgery in Patients with Positive Vertical Coma. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2017. [DOI: 10.3341/jkos.2017.58.3.268] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Ji Soo Shin
- Myung-Gok Eye Research Institute, Department of Ophthalmology, Konyang University College of Medicine, Daejeon, Korea
| | - Kyu Yeon Hwang
- Myung-Gok Eye Research Institute, Department of Ophthalmology, Konyang University College of Medicine, Daejeon, Korea
| |
Collapse
|
32
|
Choi SK, Chang JW. Higher Order Aberration and Astigmatism in Children with Hyperopic Amblyopia. KOREAN JOURNAL OF OPHTHALMOLOGY 2016; 30:53-9. [PMID: 26865804 PMCID: PMC4742646 DOI: 10.3341/kjo.2016.30.1.53] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2015] [Accepted: 09/11/2015] [Indexed: 11/23/2022] Open
Abstract
Purpose To investigate the changes in corneal higher-order aberration (HOA) during amblyopia treatment and the correlation between HOA and astigmatism in hyperopic amblyopia children. Methods In this retrospective study, a total of 72 eyes from 72 patients ranging in age from 38 to 161 months were included. Patients were divided into two groups based on the degree of astigmatism. Corneal HOA was measured using a KR-1W aberrometer at the initial visit and at 3-, 6-, and 12-month follow-ups. Correlation analysis was performed to assess the association between HOA and astigmatism. Results A total of 72 patients were enrolled in this study, 37 of which were classified as belonging to the higher astigmatism group, while 35 were assigned to the lower astigmatism group. There was a statistically significant difference in success rate between the higher and lower astigmatism groups. In both groups, all corneal HOAs were significantly reduced during amblyopia treatment. When comparing the two groups, a significant difference in coma HOA at the 12-month follow-up was detected (p = 0.043). In the Pearson correlation test, coma HOA at the 12-month follow-up demonstrated a statistically significant correlation with astigmatism and a stronger correlation with astigmatism in the higher astigmatism group than in the lower astigmatism group (coefficient values, 0.383 and 0.284 as well as p = 0.021 and p = 0.038, respectively). Conclusions HOA, particularly coma HOA, correlated with astigmatism and could exert effects in cases involving hyperopic amblyopia.
Collapse
Affiliation(s)
- Seung Kwon Choi
- Department of Ophthalmology, Inje University Ilsan Paik Hospital, Inje University College of Medicine, Goyang, Korea
| | - Ji Woong Chang
- Department of Ophthalmology, Inje University Ilsan Paik Hospital, Inje University College of Medicine, Goyang, Korea
| |
Collapse
|
33
|
Kord Valeshabad A, Wanek J, McAnany JJ, Shahidi M. Effects of optical blur reduction on equivalent intrinsic blur. Optom Vis Sci 2015; 92:494-9. [PMID: 25785538 DOI: 10.1097/opx.0000000000000563] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
PURPOSE To determine the effect of optical blur reduction on equivalent intrinsic blur, an estimate of the blur within the visual system, by comparing optical and equivalent intrinsic blur before and after adaptive optics (AO) correction of wavefront error. METHODS Twelve visually normal subjects (mean [±SD] age, 31 [±12] years) participated in this study. Equivalent intrinsic blur (σint) was derived using a previously described model. Optical blur (σopt) caused by high-order aberrations was quantified by Shack-Hartmann aberrometry and minimized using AO correction of wavefront error. RESULTS σopt and σint were significantly reduced and visual acuity was significantly improved after AO correction (p ≤ 0.004). Reductions in σopt and σint were linearly dependent on the values before AO correction (r ≥ 0.94, p ≤ 0.002). The reduction in σint was greater than the reduction in σopt, although it was marginally significant (p = 0.05). σint after AO correlated significantly with σint before AO (r = 0.92, p < 0.001), and the two parameters were related linearly with a slope of 0.46. CONCLUSIONS Reduction in equivalent intrinsic blur was greater than the reduction in optical blur after AO correction of wavefront error. This finding implies that visual acuity in subjects with high equivalent intrinsic blur can be improved beyond that expected from the reduction in optical blur alone.
Collapse
Affiliation(s)
- Ali Kord Valeshabad
- *MD, MPH †MS ‡PhD Department of Ophthalmology and Visual Sciences, University of Illinois at Chicago, Chicago, Illinois (all authors)
| | | | | | | |
Collapse
|
34
|
Choi YJ, Kang NH, Jun RM. Comparison of Corneal Higher-Order Aberrations Measured with Two Instruments Using Scheimpflug Camera System. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2015. [DOI: 10.3341/jkos.2015.56.10.1497] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Affiliation(s)
- Yeon Jung Choi
- Department of Ophthalmology, Ewha Womans University School of Medicine, Seoul, Korea
| | | | - Roo Min Jun
- Department of Ophthalmology, Ewha Womans University School of Medicine, Seoul, Korea
| |
Collapse
|
35
|
Cho AR, Kang NH, Jun RM. Relationship between Dry Eye Parameters and Anterior Corneal Higher-Order Aberrations Measured by Two Different Instruments. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2015. [DOI: 10.3341/jkos.2015.56.1.6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Ah Ran Cho
- Department of Ophthalmology, Ewha Womans University School of Medicine, Seoul, Korea
| | - Na Hee Kang
- Department of Ophthalmology, Ewha Womans University School of Medicine, Seoul, Korea
| | - Roo Min Jun
- Department of Ophthalmology, Ewha Womans University School of Medicine, Seoul, Korea
| |
Collapse
|
36
|
Sulai YN, Dubra A. Non-common path aberration correction in an adaptive optics scanning ophthalmoscope. BIOMEDICAL OPTICS EXPRESS 2014; 5:3059-73. [PMID: 25401020 PMCID: PMC4230870 DOI: 10.1364/boe.5.003059] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2014] [Revised: 08/01/2014] [Accepted: 08/04/2014] [Indexed: 05/02/2023]
Abstract
The correction of non-common path aberrations (NCPAs) between the imaging and wavefront sensing channel in a confocal scanning adaptive optics ophthalmoscope is demonstrated. NCPA correction is achieved by maximizing an image sharpness metric while the confocal detection aperture is temporarily removed, effectively minimizing the monochromatic aberrations in the illumination path of the imaging channel. Comparison of NCPA estimated using zonal and modal orthogonal wavefront corrector bases provided wavefronts that differ by ~λ/20 in root-mean-squared (~λ/30 standard deviation). Sequential insertion of a cylindrical lens in the illumination and light collection paths of the imaging channel was used to compare image resolution after changing the wavefront correction to maximize image sharpness and intensity metrics. Finally, the NCPA correction was incorporated into the closed-loop adaptive optics control by biasing the wavefront sensor signals without reducing its bandwidth.
Collapse
Affiliation(s)
- Yusufu N. Sulai
- The Institute of Optics, University of Rochester, Rochester, New York 14627, USA
| | - Alfredo Dubra
- Department of Ophthalmology, Medical College of Wisconsin, Milwaukee, Wisconsin 53226 USA
- Department of Biophysics, Medical College of Wisconsin, Milwaukee, Wisconsin 53223, USA
- Department of Biomedical Engineering, Marquette University, Milwaukee, Wisconsin 53223, USA
| |
Collapse
|
37
|
Kobashi H, Kamiya K, Hoshi K, Igarashi A, Shimizu K. Wavefront-guided versus non-wavefront-guided photorefractive keratectomy for myopia: meta-analysis of randomized controlled trials. PLoS One 2014; 9:e103605. [PMID: 25072409 PMCID: PMC4114780 DOI: 10.1371/journal.pone.0103605] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2014] [Accepted: 07/01/2014] [Indexed: 11/23/2022] Open
Abstract
Purpose To compare the efficacy, predictability, safety, and induced higher-order aberrations (HOAs) between wavefront-guided and non-wavefront-guided photorefractive keratectomy (PRK). Methods The Cochrane Central Register of Controlled Trials, PubMED, and EMBASE were searched for randomized controlled trials. Trials meeting the selection criteria were quality appraised, and data was extracted by 2 independent authors. Measures of association were pooled quantitatively using meta-analytical methods. Comparisons between wavefront-guided and non-wavefront-guided ablations were made as pooled odds ratios (ORs) or weighted mean differences. The pooled ORs and 95% confidence intervals (CIs) were computed for efficacy, safety, and predictability. The weighted mean differences and 95% CIs were used to compare induced HOAs. Results The study covered five trials involving 298 eyes. After wavefront-guided PRK, the pooled OR of achieving an uncorrected distance visual acuity of 20/20 (efficacy) was 1.18 (95% CI, 0.53–2.60; p = 0.69), the pooled OR of achieving a result within ±0.50 diopter of the intended target (predictability) was 0.86 (95% CI, 0.40–1.84; p = 0.70). No study reported a loss of 2 or more lines of Snellen acuity (safety) with either modality. In eyes with wavefront-guided PRK, the postoperative trefoil aberrations (mean difference −0.02; 95% CI, −0.03 to −0.00; p = 0.03) were significantly lower. There were no significant differences between the two groups in the postoperative total HOAs (mean difference −0.04; 95% CI, −0.23 to 0.14; p = 0.63), spherical (mean difference 0.00; 95% CI, −0.08 to 0.09; p = 0.93), and coma (mean difference −0.06; 95% CI, −0.14 to 0.03; p = 0.20) aberrations. Conclusions According to the meta-analysis, wavefront-guided PRK offered no advantage in efficacy, predictability, or safety measures over non-wavefront-guided PRK, although it may have induced fewer trefoil aberrations.
Collapse
Affiliation(s)
- Hidenaga Kobashi
- Department of Ophthalmology, University of Kitasato School of Medicine, Kanagawa, Japan
- * E-mail:
| | - Kazutaka Kamiya
- Department of Ophthalmology, University of Kitasato School of Medicine, Kanagawa, Japan
| | - Keika Hoshi
- Department of Preventive Medicine, University of Kitasato School of Medicine, Kanagawa, Japan
| | - Akihito Igarashi
- Department of Ophthalmology, University of Kitasato School of Medicine, Kanagawa, Japan
| | - Kimiya Shimizu
- Department of Ophthalmology, University of Kitasato School of Medicine, Kanagawa, Japan
| |
Collapse
|
38
|
Liu R, Zhou J, Zhao H, Dai Y, Zhang Y, Tang Y, Zhou Y. Immature visual neural system in children reflected by contrast sensitivity with adaptive optics correction. Sci Rep 2014; 4:4687. [PMID: 24732728 PMCID: PMC3986699 DOI: 10.1038/srep04687] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2013] [Accepted: 03/27/2014] [Indexed: 11/09/2022] Open
Abstract
This study aimed to explore the neural development status of the visual system of children (around 8 years old) using contrast sensitivity. We achieved this by eliminating the influence of higher order aberrations (HOAs) with adaptive optics correction. We measured HOAs, modulation transfer functions (MTFs) and contrast sensitivity functions (CSFs) of six children and five adults with both corrected and uncorrected HOAs. We found that when HOAs were corrected, children and adults both showed improvements in MTF and CSF. However, the CSF of children was still lower than the adult level, indicating the difference in contrast sensitivity between groups cannot be explained by differences in optical factors. Further study showed that the difference between the groups also could not be explained by differences in non-visual factors. With these results we concluded that the neural systems underlying vision in children of around 8 years old are still immature in contrast sensitivity.
Collapse
Affiliation(s)
- Rong Liu
- CAS Key Laboratory of Brain Function and Disease, and School of Life Sciences, University of Science and Technology of China, Hefei 230027, China
| | - Jiawei Zhou
- CAS Key Laboratory of Brain Function and Disease, and School of Life Sciences, University of Science and Technology of China, Hefei 230027, China
| | - Haoxin Zhao
- 1] Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu, China [2] The Key Laboratory on Adaptive Optics, Chinese Academy of Sciences, Chengdu 610209, China
| | - Yun Dai
- 1] Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu, China [2] The Key Laboratory on Adaptive Optics, Chinese Academy of Sciences, Chengdu 610209, China
| | - Yudong Zhang
- 1] Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu, China [2] The Key Laboratory on Adaptive Optics, Chinese Academy of Sciences, Chengdu 610209, China
| | - Yong Tang
- CAS Key Laboratory of Brain Function and Disease, and School of Life Sciences, University of Science and Technology of China, Hefei 230027, China
| | - Yifeng Zhou
- CAS Key Laboratory of Brain Function and Disease, and School of Life Sciences, University of Science and Technology of China, Hefei 230027, China
| |
Collapse
|
39
|
Legras R, Benard Y. Measurement and prediction of subjective gradations of images in presence of monochromatic aberrations. Vision Res 2013; 86:52-8. [DOI: 10.1016/j.visres.2013.04.009] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2013] [Revised: 04/10/2013] [Accepted: 04/12/2013] [Indexed: 11/16/2022]
|
40
|
Lombardo M, Serrao S, Devaney N, Parravano M, Lombardo G. Adaptive optics technology for high-resolution retinal imaging. SENSORS (BASEL, SWITZERLAND) 2012; 13:334-66. [PMID: 23271600 PMCID: PMC3574679 DOI: 10.3390/s130100334] [Citation(s) in RCA: 77] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/13/2012] [Revised: 12/05/2012] [Accepted: 12/06/2012] [Indexed: 01/18/2023]
Abstract
Adaptive optics (AO) is a technology used to improve the performance of optical systems by reducing the effects of optical aberrations. The direct visualization of the photoreceptor cells, capillaries and nerve fiber bundles represents the major benefit of adding AO to retinal imaging. Adaptive optics is opening a new frontier for clinical research in ophthalmology, providing new information on the early pathological changes of the retinal microstructures in various retinal diseases. We have reviewed AO technology for retinal imaging, providing information on the core components of an AO retinal camera. The most commonly used wavefront sensing and correcting elements are discussed. Furthermore, we discuss current applications of AO imaging to a population of healthy adults and to the most frequent causes of blindness, including diabetic retinopathy, age-related macular degeneration and glaucoma. We conclude our work with a discussion on future clinical prospects for AO retinal imaging.
Collapse
Affiliation(s)
- Marco Lombardo
- Fondazione G.B. Bietti IRCCS, Via Livenza 3, 00198 Rome, Italy; E-Mails: (S.S.); (M.P.)
| | - Sebastiano Serrao
- Fondazione G.B. Bietti IRCCS, Via Livenza 3, 00198 Rome, Italy; E-Mails: (S.S.); (M.P.)
| | - Nicholas Devaney
- Applied Optics Group, School of Physics, National University of Ireland, Galway, Ireland; E-Mail:
| | | | - Giuseppe Lombardo
- CNR-IPCF Unit of Support of Cosenza, c/o University of Calabria, Ponte P. Bucci Cubo 31/C, 87036 Rende, Italy; E-Mail:
- Vision Engineering, Via Adda 7, 00198 Rome, Italy
| |
Collapse
|
41
|
Jinabhai A, Neil Charman W, O’Donnell C, Radhakrishnan H. Optical quality for keratoconic eyes with conventional RGP lens and simulated, customised contact lens corrections: a comparison. Ophthalmic Physiol Opt 2012; 32:200-12. [DOI: 10.1111/j.1475-1313.2012.00904.x] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
42
|
Zhou J, Zhang Y, Dai Y, Zhao H, Liu R, Hou F, Liang B, Hess RF, Zhou Y. The eye limits the brain's learning potential. Sci Rep 2012; 2:364. [PMID: 22509464 PMCID: PMC3326633 DOI: 10.1038/srep00364] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2012] [Accepted: 03/23/2012] [Indexed: 12/05/2022] Open
Abstract
The concept of a critical period for visual development early in life during which sensory experience is essential to normal neural development is now well established. However recent evidence suggests that a limited degree of plasticity remains after this period and well into adulthood. Here, we ask the question, "what limits the degree of plasticity in adulthood?" Although this limit has been assumed to be due to neural factors, we show that the optical quality of the retinal image ultimately limits the brain potential for change. We correct the high-order aberrations (HOAs) normally present in the eye's optics using adaptive optics, and reveal a greater degree of neuronal plasticity than previously appreciated.
Collapse
Affiliation(s)
- Jiawei Zhou
- CAS Key Laboratory of Brain Function and Disease, and School of Life Sciences, University of Science and Technology of China, Hefei 230027
| | - Yudong Zhang
- Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu, China
- The Key Laboratory on Adaptive Optics, Chinese Academy of Sciences, Chengdu 610209, China
| | - Yun Dai
- Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu, China
- The Key Laboratory on Adaptive Optics, Chinese Academy of Sciences, Chengdu 610209, China
| | - Haoxin Zhao
- Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu, China
- The Key Laboratory on Adaptive Optics, Chinese Academy of Sciences, Chengdu 610209, China
| | - Rong Liu
- CAS Key Laboratory of Brain Function and Disease, and School of Life Sciences, University of Science and Technology of China, Hefei 230027
| | - Fang Hou
- CAS Key Laboratory of Brain Function and Disease, and School of Life Sciences, University of Science and Technology of China, Hefei 230027
| | - Bo Liang
- Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu, China
- The Key Laboratory on Adaptive Optics, Chinese Academy of Sciences, Chengdu 610209, China
| | - Robert F. Hess
- McGill Vision Research, Department of Ophthalmology, McGill University, Montreal, Canada
| | - Yifeng Zhou
- CAS Key Laboratory of Brain Function and Disease, and School of Life Sciences, University of Science and Technology of China, Hefei 230027
| |
Collapse
|
43
|
Smadja D, Reggiani-Mello G, Santhiago MR, Krueger RR. Wavefront ablation profiles in refractive surgery: description, results, and limitations. J Refract Surg 2012; 28:224-32. [PMID: 22373035 DOI: 10.3928/1081597x-20120217-01] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2011] [Accepted: 12/06/2011] [Indexed: 11/20/2022]
Abstract
PURPOSE To provide an overview of the clinical results of different ablation profiles based on wavefront technology and discuss their characteristics and limitations. METHODS Literature review of studies reporting results of ablation profiles based on wavefront technology in virgin healthy eyes. RESULTS Over the past 10 years, a large number of studies comparing different treatment algorithms and newer excimer laser platforms have been published. Thirty-six clinical studies including 3637 eyes analyzing the clinical results obtained after wavefront-guided, wavefront-optimized, and Q-factor profiles have been reviewed. Although wavefront-driven profiles allowed reduction of the amount of induced optical aberrations with conventional ablations, thereby improving the quality of vision, it appears that no algorithm of treatment or excimer laser platform has demonstrated a clear superiority over another. Wound healing and unexpected biomechanical response to surgery affect the accuracy of customized treatments and produce variable results. In addition, it is difficult to rigorously analyze and compare findings among different studies because of the diverse variety in which the data are reported. CONCLUSIONS Despite several technological improvements over the years, wavefront ablation profiles have not consistently demonstrated superiority in terms of visual acuity and lower order aberrations compared to the standard procedure, although the induction of higher order aberrations has been reduced. The concept of an individualized eye model has emerged recently, based on the optical ray tracing algorithm, and could theoretically provide a higher level of customization, thus fulfilling the promise of "super vision."
Collapse
Affiliation(s)
- David Smadja
- Refractive Surgery Department, Cole Eye Institute, Cleveland Clinic Foundation, Ohio, USA.
| | | | | | | |
Collapse
|
44
|
Smadja D, Reggiani-Mello G, Touboul D, Colin J. Les profils de photoablation cornéenne en chirurgie réfractive. Partie 1 : la quête de l’excellence. J Fr Ophtalmol 2012; 35:126-35. [DOI: 10.1016/j.jfo.2011.09.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2011] [Revised: 08/30/2011] [Accepted: 09/02/2011] [Indexed: 10/14/2022]
|
45
|
Fritzsch M, Dawczynski J, Jurkutat S, Vollandt R, Strobel J. [Monochromatic aberration in accommodation. Dynamic wavefront analysis]. Ophthalmologe 2012; 108:553-60. [PMID: 21695608 DOI: 10.1007/s00347-011-2336-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
BACKGROUND Monochromatic aberrations may influence the visual acuity of the eye. They are not stable and can be affected by different factors. The subject of the following paper is the dynamic investigation of the changes in wavefront aberration with accommodation. METHOD Dynamic measurement of higher and lower order aberrations was performed with a WASCA Wavefront Analyzer (Carl-Zeiss-Meditec) and a specially constructed target device for aligning objects in far and near distances on 25 subjects aged from 15 to 27 years old. RESULTS Wavefront aberrations showed some significant changes in accommodation. In addition to the characteristic sphere reaction accompanying miosis and changes in horizontal prism (Z(1) (1)) in the sense of a convergence movement of the eyeball also occurred. Furthermore defocus rose (Z(2) (0)) and astigmatism (Z(2) (-2)) changed. In higher-order aberrations a decrease in coma-like Zernike polynomials (Z(3) (-1), Z(3) (1)) was found. The most obvious change appeared in spherical aberration (Z(4) (0)) which increased and changed from positive to negative. In addition the secondary astigmatism (Z(4) (-2)) and quadrafoil (Z(4) (4)) rise also increased. The total root mean square (RMS), as well as the higher-order aberrations (RMS-HO) significantly increased in accommodation which is associated with a theoretical reduction of visual acuity. An analysis of the influence of pupil size on aberrations showed significant increases in defocus, spherical aberration, quadrafoil, RMS and RMS HO by increasing pupil diameter. By accommodation-associated miosis, the growing aberrations are partially compensated by focusing on near objects. Temporal analysis of the accommodation process with dynamic wavefront analysis revealed significant delays in pupil response and changing of prism in relation to the sphere reaction. In accommodation to near objects a discrete time ahead of third order aberrations in relation to the sphere response was found. CONCLUSION Using dynamic wavefront measurement achieved a sequential analysis of aberrations during accommodation. Significant changes in the lower and higher-order aberrations could be detected. These are additionally varied by the associated pupillary response. Moreover, the synchronicity of wave front reaction in the accommodation process was proven.
Collapse
Affiliation(s)
- M Fritzsch
- Klinik für Augenheilkunde, Universitätsklinikum Jena, Jena, Germany.
| | | | | | | | | |
Collapse
|
46
|
Jang JY, Oh HJ, Yoon KC. Changes of Higher-Order Aberrations after Microcoaxial Cataract Surgery According to Pupil Size. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2012. [DOI: 10.3341/jkos.2012.53.9.1260] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Jae Yong Jang
- Department of Ophthalmology, Chonnam National University Medical School, Gwangju, Korea
| | - Han Jin Oh
- Department of Ophthalmology, Chonnam National University Medical School, Gwangju, Korea
| | - Kyung Chul Yoon
- Department of Ophthalmology, Chonnam National University Medical School, Gwangju, Korea
| |
Collapse
|
47
|
Thiagarajan M, McClenaghan R, Anderson DF. Comparison of visual performance with an aspheric intraocular lens and a spherical intraocular lens. J Cataract Refract Surg 2011; 37:1993-2000. [DOI: 10.1016/j.jcrs.2011.05.046] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2010] [Revised: 04/26/2011] [Accepted: 05/12/2011] [Indexed: 10/16/2022]
|
48
|
Ravikumar S, Akeley K, Banks MS. Creating effective focus cues in multi-plane 3D displays. OPTICS EXPRESS 2011; 19:20940-52. [PMID: 21997103 PMCID: PMC3336737 DOI: 10.1364/oe.19.020940] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Focus cues are incorrect in conventional stereoscopic displays. This causes a dissociation of vergence and accommodation, which leads to visual fatigue and perceptual distortions. Multi-plane displays can minimize these problems by creating nearly correct focus cues. But to create the appearance of continuous depth in a multi-plane display, one needs to use depth-weighted blending: i.e., distribute light intensity between adjacent planes. Akeley et al. [ACM Trans. Graph. 23, 804 (2004)] and Liu and Hua [Opt. Express 18, 11562 (2009)] described rather different rules for depth-weighted blending. We examined the effectiveness of those and other rules using a model of a typical human eye and biologically plausible metrics for image quality. We find that the linear blending rule proposed by Akeley and colleagues [ACM Trans. Graph. 23, 804 (2004)] is the best solution for natural stimuli.
Collapse
Affiliation(s)
- Sowmya Ravikumar
- Vision Science Program, University of California Berkeley, California 94720,
USA
| | - Kurt Akeley
- Lytro Inc., Mountain View, 94041, California,
USA
| | - Martin S. Banks
- Vision Science Program, University of California Berkeley, California 94720,
USA
| |
Collapse
|
49
|
Fares U, Suleman H, Al-Aqaba MA, Otri AM, Said DG, Dua HS. Efficacy, predictability, and safety of wavefront-guided refractive laser treatment: metaanalysis. J Cataract Refract Surg 2011; 37:1465-75. [PMID: 21782089 DOI: 10.1016/j.jcrs.2011.02.029] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2010] [Revised: 02/23/2011] [Accepted: 02/26/2011] [Indexed: 10/18/2022]
Abstract
PURPOSE To compare the efficacy, predictability, safety, and induced higher-order aberrations (HOAs) between wavefront-guided and non-wavefront-guided ablations. SETTING Division of Ophthalmology and Visual Sciences, University of Nottingham, Nottingham, United Kingdom. DESIGN Metaanalysis. METHODS The Cochrane Central Register of Controlled Trials, PubMED, and EMBASE were searched for randomized controlled trails. Trials meeting the selection criteria were quality appraised and data extracted by 2 independent authors. Measures of association were pooled quantitatively using metaanalytical methods. Comparison between wavefront-guided and non-wavefront-guided ablations was measured as pooled odds ratios (ORs) or weighted mean differences. The pooled ORs and 95% confidence intervals (CIs) were computed for efficacy, safety, and predictability. The weighted mean difference and 95% CIs were used to compare induced HOAs. RESULTS Eight trials involving 955 eyes were included. After wavefront-guided LASIK, the pooled OR of achieving uncorrected distance visual acuity (UDVA) of 20/20 (efficacy) was 1.10 (95% CI, 0.66-1.83; P=.72), the pooled OR of achieving a result within ± 0.50 diopter of intended target (predictability) was 1.03 (95% CI, 0.60-1.75; P=.92), and the weighted mean difference in induced HOAs was -0.09 (95% CI, -0.17 to -0.01; P=.04). No study reported loss of 2 or more lines of Snellen acuity (safety) with either modality. CONCLUSIONS Metaanalysis showed no clear evidence of a benefit of wavefront-guided over non-wavefront-guided ablations. However, there was a lack of standardized reporting of UDVA better than 20/20, which might mask an advantage in wavefront-guided treatment. With high preexisting HOAs, wavefront-guided has advantages over non-wavefront-guided treatment.
Collapse
Affiliation(s)
- Usama Fares
- Division of Ophthalmology and Visual Sciences, University of Nottingham, Nottingham, United Kingdom
| | | | | | | | | | | |
Collapse
|
50
|
Williams DR. Imaging single cells in the living retina. Vision Res 2011; 51:1379-96. [PMID: 21596053 DOI: 10.1016/j.visres.2011.05.002] [Citation(s) in RCA: 110] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2011] [Revised: 04/29/2011] [Accepted: 05/01/2011] [Indexed: 12/31/2022]
Abstract
A quarter century ago, we were limited to a macroscopic view of the retina inside the living eye. Since then, new imaging technologies, including confocal scanning laser ophthalmoscopy, optical coherence tomography, and adaptive optics fundus imaging, transformed the eye into a microscope in which individual cells can now be resolved noninvasively. These technologies have enabled a wide range of studies of the retina that were previously impossible.
Collapse
Affiliation(s)
- David R Williams
- Center for Visual Science, William G. Allyn Professor of Medical Optics, University of Rochester, Rochester, NY 14627-0270, United States.
| |
Collapse
|