1
|
Ajla P, Melisa AP, Ivana M, Senad G, Alma B, Aida P. Laser keratomileusis in treatment of anisometropic amblyopia in adults. Taiwan J Ophthalmol 2021; 12:452-456. [PMID: 36660114 PMCID: PMC9843570 DOI: 10.4103/tjo.tjo_22_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Accepted: 05/05/2021] [Indexed: 01/22/2023] Open
Abstract
PURPOSE To compare and evaluate improvement in corrected distant visual acuity (CDVA) between myopia and hyperopia after laser in situ keratomileusis (LASIK) in adult patients with anisometropic amblyopia. MATERIALS AND METHODS This prospective clinical study included 103 amblyopic eyes (103 patients), which underwent LASIK correction of refractive error from January 2013 to January 2018. Uncorrected distance visual acuity (UDVA), CDVA, spherical equivalent (SE), postoperative astigmatism, and intraocular pressure were evaluated at time points of 1, 6, and 12 months. RESULTS Patients were divided into two groups according to refractive error. Group 1: Forty-six patients with myopia and Group 2: Fifty-seven patients with hyperopia. Mean CDVA (logarithm of the minimum angle of resolution [logMAR]) preoperatively was 0.23 ± 0.16 in Group 1 and 0.40 ± 0.19 in Group 2. Postoperative CDVA (logMAR) was 0.17 ± 0.13 in Group 1 and 0.32 ± 0.17 in Group 2. There was statistically significant increase in UDVA (P < 0.0001) postoperatively and no change during the follow-up period of 12 months in both groups. Group 1 showed more expectable results, 95% of variability SE achieved was dependent on SE intended (R2 = 0.95), while in Group 2, the percentage was slightly lower of expected 87% (R2 = 0.87). There was statistical significance in respect of CDVA change postoperatively and preoperatively in both groups. Correlation factors are low, in Group 1 r = -0.53 and in Group 2 r = -0.39. CONCLUSION LASIK can improve CDVA in a considerable portion of amblyopic eyes, both myopic and hyperopic. Eyes with better initial CDVA and those with myopia were associated with greater improvement in postoperative CDVA.
Collapse
Affiliation(s)
- Pidro Ajla
- Eye Clinic Svjetlost, Sarajevo, Bosnia and Herzegovina,Address for correspondence: Dr. Pidro Ajla, Kalemova 9, Sarajevo, Bosnia and Herzegovina. E-mail:
| | | | | | | | - Biščević Alma
- Eye Clinic Svjetlost, Sarajevo, Bosnia and Herzegovina
| | - Pidro Aida
- Department of Ophthalmology, General Hospital Sarajevo, Sarajevo, Bosnia and Herzegovina
| |
Collapse
|
2
|
[Regression and ablation profiles in corneal refractive surgery]. J Fr Ophtalmol 2021; 44:1059-1075. [PMID: 34148702 DOI: 10.1016/j.jfo.2020.08.041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Revised: 08/16/2020] [Accepted: 08/24/2020] [Indexed: 11/21/2022]
Abstract
Regression after corneal refractive surgery is a complex phenomenon which seems inevitable. The choice of surgical technique has very little influence on regression for low myopia or myopic astigmatism. However, LASIK and SMILE are the two techniques of choice in the correction of high myopia. LASIK is also better for the correction of hyperopia, hyperopic astigmatism and mixed astigmatism. Intraoperatively, the choice of a wide optical zone and adherence to a thick residual stromal bed provide stability. Regression may also be reduced by modulating anti-inflammatory therapy, treating dry eye, and using mitomycin C in PKR. In all cases, obtaining keratometry during patient follow-up helps to identify the cause of the regression. The objective of this review is to synthesize recent data from the literature on regression in refractive surgery as a function of the ablation profiles used.
Collapse
|
3
|
Six-Month Outcomes After High Hyperopia Correction Using Laser-Assisted In Situ Keratomileusis With a Large Ablation Zone. Cornea 2019; 38:1147-1153. [PMID: 31169605 DOI: 10.1097/ico.0000000000002011] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To evaluate refractive and visual outcomes of laser-assisted in situ keratomileusis (LASIK) to treat high hyperopia using an aberration-neutral profile and large ablation zone. METHODS This was a retrospective, consecutive observational case series at Helios Ophtalmologie, St. Jean-de-Luz, France. One hundred forty-six consecutive eyes of 77 patients who underwent LASIK with mechanical microkeratome to correct hyperopia with correction in the maximum hyperopic meridian strictly higher than +5 D (mean + 6.6 ± 1.0 D) were included. Procedures were performed with an Amaris 750S excimer laser (Schwind eye-tech-solutions GmbH, Kleinostheim, Germany) using an aberration-neutral profile, a 6.7 ± 0.1 mm optical zone, and a 9.2 ± 0.1 mm total ablation zone. Refractive results, predictability, safety, and efficacy were evaluated at 6 months postoperatively. RESULTS At 6 months postsurgery, the mean manifest refraction spherical equivalent was -0.06 ± 0.83 D and the mean cylinder was 0.42 ± 0.35 D. Sixty-six percent of eyes were within ±0.50 D of the attempted spherical equivalent correction. Six months postoperatively, 60% of eyes achieved an uncorrected distance visual acuity of 20/20 or better. Ten percent of eyes lost 1 line of corrected distance visual acuity and 4% gained a line. No eyes lost more than 2 Snellen lines of corrected distance visual acuity at any follow-up. CONCLUSIONS High hyperopia correction with LASIK using an aberration-neutral profile and large ablation zone provides good efficacy, safety, predictability, and visual outcomes.
Collapse
|
4
|
Roesler C, Kohnen T. Changes of Functional Optical Zone After LASIK for Hyperopia and Hyperopic Astigmatism. J Refract Surg 2018; 34:476-481. [PMID: 30001451 DOI: 10.3928/1081597x-20180515-03] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2017] [Accepted: 05/07/2018] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate which factors may influence the size of the postoperative functional optical zone after hyperopic LASIK. METHODS Thirty-three eyes with a mean spherical equivalent of +3.55 ± 1.28 diopters (D) underwent LASIK with a Technolas 217 C-LASIK laser (Bausch & Lomb Surgical, Munich, Germany). After 1 week and 1, 4, and 12 months, the authors examined refraction, corneal refractive power by means of computerized videokeratography (Technomed C-Scan; Baesweiler, Germany), and uncorrected/corrected distance visual acuity (UDVA/CDVA). According to the degree of hyperopia, they were divided into low hyperopia (spherical equivalent ≤ 3.00 D) and high hyperopia (spherical equivalent > 3.00 D) groups. RESULTS One year postoperatively, 82% of all eyes had a UDVA of 0.5 or better; in 88%, the spherical equivalent did not deviate more than 1.00 D from the attempted value. Three eyes were slightly undercorrected. After an initial overcorrection (-0.27 D) with subsequent regression, the refraction remained stable at +0.17 D from the fourth postoperative month (low hyperopia group: +0.14 D; high hyperopia group: +0.19 D after 1 year). After 1 year, the functional optical zone diminished by 32%; the reduction was more pronounced in eyes with higher hyperopia: -1.85 ± 1.09 mm (range: +0.5 to -3.4 mm) in the low hyperopia group (P < .0001) and -2.25 ± 1.24 mm (range: +1 to -3.9 mm) in the high hyperopia group (P < .0001). Preoperative spherical equivalent and preoperative corneal refractive power affected the postoperative size of the functional optical zone additively. CONCLUSIONS An expected small functional optical zone in high hyperopia may not be regarded as a compelling exclusion criterion, but can induce possible side effects such as glare and halos. [J Refract Surg. 2018;34(7):476-481.].
Collapse
|
5
|
Reinstein DZ, Gobbe M, Archer TJ, Carp GI. Mechanism for a Rare, Idiosyncratic Complication Following Hyperopic LASIK: Diurnal Shift in Refractive Error Due to Epithelial Thickness Profile Changes. J Refract Surg 2016; 32:364-71. [DOI: 10.3928/1081597x-20160428-05] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2015] [Accepted: 02/04/2016] [Indexed: 11/20/2022]
|
6
|
Falcon C, Norero Martinez M. [Safety of the automated microkeratome for Sub-Bowman's Keratomileusis on the flat cornea]. J Fr Ophtalmol 2015; 39:202-9. [PMID: 26549141 DOI: 10.1016/j.jfo.2015.07.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2015] [Revised: 07/09/2015] [Accepted: 07/29/2015] [Indexed: 10/22/2022]
Abstract
INTRODUCTION Use of the One Use-Plus SBK (Sub-Bowman's Keratomileusis) automated microkeratome (Moria, Antony, France) has been shown to be safe, predictable and comfortable for the creation of thin corneal flaps with a smooth and regular stromal bed. PURPOSE To evaluate the use of the Moria One Use-Plus SBK (Moria, Antony, France) automated microkeratome on corneas with 180°-keratometry under 40 diopters (D). METHODS We retrospectively studied cases that underwent SBK whose 180°-keratometry was under 40 D. We separated the cases between 39 and 40 D and those less than 39 D. The preoperative data, the procedure and the postoperative outcomes were analyzed. The Moria One Use-Plus SBK microkeratome with the 90-micron head was used for all cases. RESULTS Among the 2883 eyes that underwent SBK LASIK over the past six years, 80 eyes (2.77%) had a preoperative topographical 180°-keratometry of less than 40 D: 63 eyes (2.19%) between 39 and 40 D and 17 eyes (0.59%) between 38 and 39 D (38.13-38.97 D). The spherical equivalent was between -3.50 D (-2.25 sph -2.50 cyl. at 175°) and+6.00 D (+5.50 sph +1.00 cyl. at 85°). Fifty-eight eyes (72.5%) had hyperopia and/or hyperopic astigmatism; 18 eyes (22.5%) had mixed astigmatism; and 4 eyes (5%) had myopia and/or myopic astigmatism. Twenty-six eyes (32%) had a history of strabismus. Thirteen patients (27.66%) had a history of amblyopia. The "-1" ring was used in all cases, with a 7.5 stop (14%) or 8 stop (86%). The procedure went uneventfully in all cases with a stable vacuum between 117 and 123 mm Hg. The nasal hinge and the stromal bed were normal in size in all cases and sufficient to perform the photoablation laser safely with an optical zone between 6.00 and 7.00 millimeters. There were no intraoperative nor immediate postoperative complications: free cap 0%; incomplete flap 0%; button hole 0%; epithelial erosion 0%; bleeding 0%; irregular stromal bed 0%. Postoperative complications: flap displacement 0%; punctate keratitis: 8%; LASIK retreatments: 12%; safety: 100% (no loss of lines of visual acuity). DISCUSSION Corneas with a topographical 180°-keratometry under 40 D are a very small percentage of the total eyes that undergo LASIK (SBK). Those with a 180°-keratometry under 39 D are even more infrequent. Due to the characteristics of the flat cornea, the percentage of hyperopia is much larger in than in the general LASIK group. In addition, the percentage with a history of strabismus and amblyopia is higher. CONCLUSION The Moria One Use-Plus SBK microkeratome is an excellent device that allows the easy creation of thin corneal flaps and regular and smooth corneal beds, safely and predictably even in extremely flat corneas without complications. The safety, efficacy and predictability are quite comparable to the general LASIK group.
Collapse
Affiliation(s)
- C Falcon
- Clinique Optima Laser, Gran Via Germanias, 6, 46006 Valencia, Espagne.
| | - M Norero Martinez
- Clinique Optima Laser, Gran Via Germanias, 6, 46006 Valencia, Espagne
| |
Collapse
|
7
|
Falcon C, Norero Martínez M, Sancho Miralles Y. [Laser Blended Vision for presbyopia: Results after 3 years]. J Fr Ophtalmol 2015; 38:431-9. [PMID: 25910743 DOI: 10.1016/j.jfo.2015.02.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2014] [Revised: 01/29/2015] [Accepted: 02/04/2015] [Indexed: 11/15/2022]
Abstract
PURPOSE Retrospective study of the first 173 patients with presbyopia who underwent LASIK with a non-linear aspheric ablation profile and micro-monovision for the correction of presbyopia with myopia, astigmatism, hyperopia or emmetropia: Laser Blended Vision(®) Program by Carl Zeiss Meditec(®) (Jena, Germany). METHODS We retrospectively studied the first consecutive 173 patients with presbyopia who underwent LASIK with the wavefront-guided Laser Blended Vision(®) Program by Zeiss(®) in our Excimer Laser Zeiss Mel-80 by Carl Zeiss Meditec(®) (Jena, Germany) over the last three years in our clinic (Optima Laser Clinic, Valence, Spain). The program has a non-linear aspheric ablation profile that increases the spherical aberration in both eyes. A slight myopia of -1.5 diopters (D) in the non-dominant eye is also programmed. We analysed the results and patient satisfaction. The patients were separated into two groups: less than 50 years old and 50 years or more. Follow-up was from 1 to 28 months. We also separated two groups: follow-up under 12 months and follow-up of 12 months or more. We analysed the efficacy, safety and predictability of the procedure. RESULTS Seventy-nine male and 94 female patients between 42 and 69 years old were studied, for a total of 337 eyes. Only eight patients (4.62%) were between 42 and 44; 55 (31.79%) were between 45 and 49; 110 patients (63.58%) were 50 years or more. Nine patients underwent the surgery in the non-dominant eye only. Twelve (6.94%) patients were emmetropic (0.5 or less spherical equivalent), 42 (24.28%) were myopic or myopic astigmatic, and 119 (68.79%) were hyperopic or hyperopic astigmatic. One hundred and thirty-six patients (78.61%) had pre-operative near vision between J4 and J10. One hundred and seventy-one patients (98.84%) had post-operative near vision between J1 and J3; 150 (86.7%) had J1 (efficacy). Post-operative visual acuity without correction for distance was 20/20 or better in 159 patients (91.91%) (binocular). The predictability within 0.5 D was 87.86%. Safety 99.7% (336/337 eyes): one eye of a diabetic patient lost two lines BCVA. A total of 93.64% were satisfied with the procedure, 2.89% used eye-glasses for certain activities, 1.73% reported dry eye, 0.58% reported a nonspecific lack of adaptation, and there were no serious complications; 3.47% did not achieve their expectations. Twenty-four patients (13.87%) needed an enhancement, 18 of them (75.5%) for only one eye, with 88.89% of these being the non-dominant eye. Forty-nine patients (28.32%) had over 12 months follow-up, with 95.92% still satisfied. CONCLUSIONS Laser Blended Vision(®) is an excellent option, well tolerated, stable and effective for patients with presbyopia and myopia, astigmatism, hyperopia or emmetropia, also avoiding an intraocular procedure.
Collapse
Affiliation(s)
- C Falcon
- Clinique Optima Laser, Gran Via Germanias, 6, 46006 Valencia, Espagne.
| | - M Norero Martínez
- Clinique Optima Laser, Gran Via Germanias, 6, 46006 Valencia, Espagne
| | - Y Sancho Miralles
- Clinique Optima Laser, Gran Via Germanias, 6, 46006 Valencia, Espagne
| |
Collapse
|
8
|
Fang L, Wang Y, He X. Theoretical analysis of wavefront aberration caused by treatment decentration and transition zone after custom myopic laser refractive surgery. J Cataract Refract Surg 2013; 39:1336-47. [DOI: 10.1016/j.jcrs.2013.03.020] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2012] [Revised: 12/31/2012] [Accepted: 03/08/2013] [Indexed: 11/17/2022]
|
9
|
Alio JL, Pachkoria K, El Aswad A, Plaza-Puche AB. Laser-assisted in situ keratomileusis in high mixed astigmatism with optimized, fast-repetition and cyclotorsion control excimer laser. Am J Ophthalmol 2013; 155:829-36. [PMID: 23394913 DOI: 10.1016/j.ajo.2012.11.027] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2011] [Revised: 11/28/2012] [Accepted: 11/28/2012] [Indexed: 11/19/2022]
Abstract
PURPOSE To evaluate the visual refractive and aberrometric outcomes of laser-assisted in situ keratomileusis (LASIK) surgery for the correction of high mixed astigmatism using a new-generation excimer laser and optimized aspherical profiles. DESIGN Retrospective interventional case series. METHODS Fifty-two eyes of 36 patients (21-53 years) with primary mixed astigmatism over 3.0 diopters (D) were included. All cases underwent LASIK surgery using the sixth-generation excimer laser Amaris with cyclotorsion control and a femtosecond platform for flap creation. Visual, refractive, corneal topographic, and aberrometric outcomes were evaluated during a 3-month follow-up. Refractive astigmatic changes were analyzed by Alpins method. RESULTS A significant reduction of refractive sphere and cylinder was observed 3 months postoperatively (P = .001), with an associated improvement of uncorrected distance visual acuity (P = .001). Best-corrected distance visual acuity (CDVA) remained unchanged in 31 eyes (59.6%), while 3 eyes (5.76%) lost 2 lines of CDVA. Fourteen eyes (26.9%) had spherical equivalent (SE) within ±0.5 D of emmetropia and 34 (65.3%) had SE within ±1.0 D of emmetropia. No significant difference was observed when comparing surgically induced and target astigmatism. A significant induction of higher-order aberration attributable to increase of spherical aberration was found (P = .003). Seven eyes (13.4%) required retreatment. CONCLUSIONS LASIK for primary high mixed astigmatism using optimized aspherical profiles and a fast-repetition-rate excimer laser with cyclotorsion control is a safe, effective, and predictable procedure. Induction of higher-order aberrations is still present in the correction of the refraction error of the magnitude included in this study.
Collapse
Affiliation(s)
- Jorge L Alio
- Instituto Oftalmológico de Alicante, Vissum Corporation, Alicante, Spain.
| | | | | | | |
Collapse
|
10
|
Kanellopoulos AJ, Kahn J. Topography-guided hyperopic LASIK with and without high irradiance collagen cross-linking: initial comparative clinical findings in a contralateral eye study of 34 consecutive patients. J Refract Surg 2013; 28:S837-40. [PMID: 23447898 DOI: 10.3928/1081597x-20121005-05] [Citation(s) in RCA: 64] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the safety and efficacy of intrastromally applied collagen cross-linking (CXL) in a comparative contralateral eye study of topography-guided femtosecond laser-assisted hyperopic LASIK. METHODS Thirty-four consecutive patients with hyperopia and hyperopic astigmatism elected to have bilateral topography-guided LASIK and were randomized to receive a single drop of 0.1% sodium phosphate riboflavin solution under the flap followed by 3-minute exposure of 10 mW/cm2 ultraviolet A (UVA) light with the flap realigned in one eye (CXL group) and no intrastromal CXL in the contralateral eye (no CXL group). All eyes were treated with the WaveLight FS200 femtosecond laser and WaveLight EX500 excimer laser (Alcon Laboratories Inc). Refractive error and keratometric, topographic, and tomographic measurements were evaluated over mean follow-up of 23 months. RESULTS Preoperatively, mean spherical equivalent refraction was +3.15 +/- 1.46 diopters (D) and +3.40 +/- 1.78 D with a mean cylinder of 1.20 +/- 1.18 D and 1.40 +/- 1.80 D and mean uncorrected distance visual acuity (UDVA) (decimal) of 0.1 +/- 0.26 and 0.1 +/-0.25 in the CXL and no CXL groups, respectively. At 2 years postoperatively, mean spherical equivalent refraction was -0.20 +/- 0.56 D and +0.20 +/- 0.40 D with mean cylinder of 0.65 +/- 0.56 D and 0.76 +/- 0.72 D and mean UDVA of 0.95 +/- 0.15 and 0.85 +/- 0.23 in the CXL and no CXL groups, respectively. Eyes with CXL demonstrated a mean regression from treatment of +0.22 +/- 0.31 D, whereas eyes without CXL showed a statistically significant greater regression of +0.72 +/- 0.19 D (P = .0001). CONCLUSIONS Topography-guided hyperopic LASIK with or without intrastromal CXL is safe and effective, with greater long-term efficacy (less regression) in eyes with CXL. Our data suggest that the regression seen with hyperopic LASIK may be related to biomechanical changes in corneal shape over time.
Collapse
|
11
|
Gifford P, Swarbrick HA. The effect of treatment zone diameter in hyperopic orthokeratology. Ophthalmic Physiol Opt 2009; 29:584-92. [DOI: 10.1111/j.1475-1313.2009.00672.x] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
12
|
Reinstein DZ, Couch DG, Archer TJ. LASIK for hyperopic astigmatism and presbyopia using micro-monovision with the Carl Zeiss Meditec MEL80 platform. J Refract Surg 2009; 25:37-58. [PMID: 19244952 DOI: 10.3928/1081597x-20090101-07] [Citation(s) in RCA: 85] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the monocular and binocular outcomes of LASIK for a micro-monovision protocol for the correction of hyperopic astigmatism and presbyopia. METHODS A prospective non-comparative case series included 258 eyes of 129 consecutive patients with hyperopic astigmatism and presbyopia who were treated with LASIK-induced micro-monovision. The CRS-Master software was used to generate ablation profiles for the Carl Zeiss Meditec MEL80 excimer laser. The target refraction was piano for distance eyes (dominant eye) and between -1.00 and -1.50 diopters (D) for near eyes. Patients were followed for 1 year. RESULTS Mean attempted spherical equivalent refraction (SE) correction was +2.54+/-1.16 D (range: +0.25 to +5.75 D). Mean attempted cylinder was -0.52+/-0.49 D (range: -0.00 to -3.25 D). Median age was 56 years (range: 44 to 66 years). Median follow-up was 12.5 months (range: 3.3 months [early retreatment] to 18.2 months). The retreatment rate was 22%. Outcome measures after all treatments were as follows. Mean deviation from the intended SE correction was +0.09+/-0.48 D, with 79% of eyes within +/-0.50 D and 95% within +/-1.00 D. The cylinder correction ratio was 1.23+/-0.63 and the error ratio was 0.67+/-0.65. Of the distance eyes, 86% achieved uncorrected visual acuity of 20/20 and 100% achieved 20/40. Binocularly, 95% of patients achieved 20/20 and 100% achieved 20/40. Eighty-one percent of patients could read J2 and 100% could read J5. Binocularly, 95% of patients achieved 20/20 and could read J5. No eyes lost 2 or more lines of best spectacle-corrected visual acuity. A statistically significant increase was noted in contrast sensitivity at 3 and 6 cycles per degree (cpd), with no reduction at 12 and 18 cpd. The average change in refraction between 3 months and 1 year was +0.11+/-0.36 D with a change of >1.00 D in 2.6% of eyes. CONCLUSIONS This hyperopic micro-monovision protocol was a well-tolerated and effective procedure for treating patients with presbyopia in moderate to high hyperopia with corrections ranging up to +5.75 D. Contrast sensitivity was improved and the distance vision of near eyes was found to contribute positively to binocular distance vision compared to distance eyes monocularly.
Collapse
|
13
|
De Ortueta D, Haecker C. Laser in situ keratomileusis for mixed astigmatism using a modified formula for bitoric ablation. Eur J Ophthalmol 2009; 18:869-76. [PMID: 18988155 DOI: 10.1177/112067210801800603] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
PURPOSE To evaluate the results of treatment of mixed astigmatism with laser in situ keratomileusis (LASIK) by means of a modified Chayet formula for bitoric ablation and personalized nomogram calculations. METHODS A retrospective study was conducted in 19 consecutive eyes of 13 patients who underwent LASIK treatment of mixed astigmatism with a mean sphere of +1.63-/+1.23 D and a mean cylinder of -3.55-/+1.17 D. The authors used the Schwind ESIRIS Laser platform. The ablation was shifted from the pupil center to the vertex normal of the cornea. RESULTS Three months postoperatively, the mean sphere was 0.08-/+0.24 D and the mean astigmatism -0.45-/+0.31 D. At 3 months, an uncorrected visual acuity (UCVA) of 20/50 or better could be found in 100% of the eyes, and of 20/25 or better in 59%. All eyes were within -/+0.5 D spherical equivalent (SE) at 3, 6, and 12 months. No eye lost more than one line of best spectacle-corrected visual acuity (BSCVA). Postoperatively, the corneal wavefront showed a reduction of spherical aberrations and coma, which were analyzed at 4 and 6 mm pupil diameter. The postoperative higher-order aberrations decreased at 4 mm and increased at 6 mm pupil sizes after surgery. CONCLUSIONS Modified bitoric treatment with the Schwind ESIRIS laser showed an excellent postoperative UCVA and BSCVA with applying external nomogram adjustments. The method demonstrated good predictability, safety, and effectiveness in the treatment of mixed astigmatism.
Collapse
Affiliation(s)
- D De Ortueta
- Augenlaserzentrum Recklinghausen, Recklinghausen - Germany.
| | | |
Collapse
|
14
|
Maldonado MJ, Nieto JC, Piñero DP. Advances in technologies for laser-assisted in situ keratomileusis (LASIK) surgery. Expert Rev Med Devices 2008; 5:209-29. [PMID: 18331182 DOI: 10.1586/17434440.5.2.209] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Laser-assisted in situ keratomileusis (LASIK) has become the most widely used form of refractive surgery today. The objective of this surgical technique is to modify the anterior corneal shape by ablating tissue from the stroma by means of the excimer laser after creating a hinged corneal flap. This way, we are able to change the refractive status of the patient, providing better unaided vision. Continuous improvements in the original technique have made the surgical procedure safer, more accurate and repeatable. These progressions are due to the development of novel technologies that are the responsible for new surgical instrumentation, which makes the surgical procedure easier for the surgeon, and better excimer laser ablation algorithms, which increase the optical quality of the ablation and thus the safety of the vision correction procedure. This article aims to describe the more relevant advances in LASIK that have played an important role in the spread and popularity of this technique.
Collapse
Affiliation(s)
- Miguel J Maldonado
- Department of Ophthalmology, Clínica Universitaria, University of Navarra, Avda Pio XII, 36, 31080, Pamplona, Spain.
| | | | | |
Collapse
|
15
|
Yin ZQ, Wang H, Yu T, Ren Q, Chen L. Facilitation of amblyopia management by laser in situ keratomileusis in high anisometropic hyperopic and myopic children. J AAPOS 2007; 11:571-6. [PMID: 17604197 DOI: 10.1016/j.jaapos.2007.04.014] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/14/2007] [Revised: 04/23/2007] [Accepted: 04/14/2007] [Indexed: 11/21/2022]
Abstract
PURPOSE To assess the efficacy of laser in situ keratomileusis (LASIK) in facilitating amblyopia management of children from 6 to 14 years old, with high hyperopic and myopic anisometropia. PATIENTS AND METHODS Between 2000 and 2005, 42 children with high hyperopic anisometropic amblyopia and 32 children with high myopic anisometropic amblyopia underwent LASIK to reduce their anisometropia. LASIK was performed under topical or general anesthesia. Pre- and postoperative best-corrected visual acuity, cycloplegic refraction, and binocular vision were recorded. Follow-up ranged from 6 months to 3 years, the averages of which were 17.45 months in the hyperopic group and 18.31 months in myopic group. RESULTS Hyperopic anisometropia correction ranged from +3.50 D to +7.75 D, and the mean postoperative anisometropia was +0.56 +/- 0.75 D at 3 years. Myopic anisometropia correction ranged from -15.75 to -5.00 D and the mean postoperative anisometropia at 3 years was -2.20 +/- 1.05 D. The best-corrected visual acuity for distance and reading in the myopic group improved from 0.4 +/- 0.25 and 0.58 +/- 0.27, respectively, before surgery to 0.59 +/- 0.28 and 0.96 +/- 0.35, respectively, 3 years after surgery. In the hyperopic group, best-corrected visual acuity for distance and reading improved from 0.23 +/- 0.21 and 0.34 +/- 0.32, respectively, before surgery to 0.53 +/- 0.31 and 0.80 +/- 0.33, respectively, 3 years after surgery. The proportion of patients who had stereopsis increased from 19.1% preoperatively to 46.7% postoperatively in the hyperopic group and from 19% to 89% in the myopic group. CONCLUSIONS LASIK reduced high hyperopic and myopic anisometropia in children, thus facilitating amblyopia management and improving their visual acuity and stereopsis.
Collapse
Affiliation(s)
- Zheng Qin Yin
- Southwest Eye Hospital/Southwest Hospital, Chongqing, China.
| | | | | | | | | |
Collapse
|
16
|
O'Brart DPS, Mellington F, Jones S, Marshall J. Laser Epithelial Keratomileusis for the Correction of Hyperopia Using a 7.0-mm Optical Zone With the Schwind ESIRIS Laser. J Refract Surg 2007; 23:343-54. [PMID: 17455829 DOI: 10.3928/1081-597x-20070401-06] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To investigate the efficacy of laser epithelial keratomileusis (LASEK) for the correction of hyperopia using a 7.0-mm optical zone and a 9.0-mm total ablation zone diameter with the Schwind ESIRIS flying-spot laser. METHODS Forty-seven patients (70 eyes) were treated with a mean preoperative spherical equivalent refraction of +2.32 diopters (D) (range: 0 to +5.00 D). All eyes underwent LASEK using 15% alcohol with a 20-second application. RESULTS An intact epithelial flap was obtained in 66 (94%) eyes. In 70 eyes at 12 months, the mean spherical equivalent refraction was +0.09 D (range: -0.75 to +1.00 D) with all (100%) eyes within +/- 1.00 D of the intended correction and 60 (86%) eyes within +/- 0.50 D. In 40 eyes with 24-month follow-up, the refractive correction remained stable after 6 months. Hyperopic cylindrical corrections were attempted in 49 eyes (range: +0.25 to +5.00 D) with vector analysis demonstrating a mean 102% correction at 12 to 24 months. In 60 non-amblyopic eyes, uncorrected visual acuity was > or = 20/20 in 47 (78%) eyes. Thirty-three (47%) eyes gained 1 to 2 lines of Snellen decimal equivalent best spectacle-corrected visual acuity, 30 (43%) eyes showed no change, and 7 (10%) eyes lost 1 line. Eight (11%) eyes at 12 to 24 months had grade +/- 1 of paracentral corneal haze and 57 (81%) had no haze. At 12 months (n = 70), the safety index was 1.06 with an efficacy index of 0.95. Analysis of higher order wavefront aberrations showed no significant changes in root-mean-square values post-operatively, except for a significant reduction of fourth order spherical aberration (P < .05). CONCLUSIONS Laser epithelial keratomileusis for hyperopia up to +5.00 D using a 7.0-mm optical zone with the Schwind ESIRIS laser provides excellent refractive and visual outcomes with minimal complications. In eyes followed for 24 months, the refractive correction remained stable after 6 months.
Collapse
Affiliation(s)
- David P S O'Brart
- Department of Ophthalmology, St Thomas' Hospital, London, United Kingdom.
| | | | | | | |
Collapse
|
17
|
Asbell P. Is conductive keratoplasty the treatment of choice for presbyopia? EXPERT REVIEW OF OPHTHALMOLOGY 2007. [DOI: 10.1586/17469899.2.1.121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
18
|
Abstract
Surgical attempts to correct hyperopia have yielded varying results over the last 130 years. These techniques include the reshaping of the cornea through incisions, burns, or lamellar cuts with removal of peripheral tissue; the addition of central inlays; laser ablations; and the replacement of the crystalline lens. By examining the success of each surgical technique, the refractive surgeon may be able to make an informed decision on its indications and limitations, based on the specific patient's characteristics. Reporting the outcomes and complications of hyperopic surgery will help refine our approach to the management of an increasingly hyperopic and presbyopic population.
Collapse
Affiliation(s)
- Salomon Esquenazi
- LSU Eye Center and LSU Neuroscience Center, Louisiana State University Health Sciences Center, New Orleans, USA.
| | | | | |
Collapse
|
19
|
Maldonado MJ, Juberías JR, Piñero DP, Alvarez-Vidal A, Rutzen AR. Flap tearing during lift-flap laser in situ keratomileusis retreatment. J Cataract Refract Surg 2006; 31:2016-8. [PMID: 16338577 DOI: 10.1016/j.jcrs.2005.06.038] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2005] [Accepted: 02/10/2005] [Indexed: 11/25/2022]
Abstract
A flap tear occurred during laser in situ keratomileusis (LASIK) retreatment using a flap-lifting technique in 1 eye of 2 patients 4 to 5 months after the primary procedure. In the first case, the tear occurred in a decentered, standard thickness flap (168 mum) in a location close to the corneal limbus and limbal vessels. In the second case, the tear occurred in a well-centered thin flap (116 mum) that involved a peripheral corneal pannus. The false track was identified early, and central extension of the tear was averted. After the flap was successfully dissected, retreatment was performed without further complications. This report suggests that flaps with margins near the limbus or a corneal pannus may be prone to an earlier and stronger healing process at the edge that may lead to a flap tear during LASIK retreatment. This may be of increasing importance because of the trend toward larger flap diameters.
Collapse
Affiliation(s)
- Miguel J Maldonado
- Department of Ophthalmology, University Clinic, University of Navarra, Pamplona, Spain.
| | | | | | | | | |
Collapse
|
20
|
Abstract
PURPOSE To evaluate the safety and efficacy of the ALLEGRETTO WAVE excimer laser system (WaveLight Laser Technologie AG, Erlangen, Germany) in LASIK for hyperopia and hyperopic astigmatism. METHODS One hundred twenty consecutive LASIK cases for hyperopia with or without astigmatism treated with the ALLEGRETTO WAVE excimer laser were prospectively evaluated up to 12 months postoperatively. Patients were allocated into three groups according to their refractive sphere and cylinder: a low hyperopia group, with up to +3.00 diopters (D) sphere and astigmatism < or = +1.00 D (n = 52); a moderate hyperopia group with +3.25 to +5.00 D sphere and astigmatism of < or = +1.00 D (n = 45); and a high hyperopia/toric group with sphere > or = +5.25 D or cylinder > or = +1.25.D (n = 23). Flaps were created with the Moria M2 microkeratome (Moria, Antony, France). Parameters evaluated were pre- and postoperative refractive error, uncorrected visual acuity, best spectacle-corrected visual acuity (BSCVA), higher order aberration change, and contrast sensitivity. RESULTS One hundred twelve eyes (93%) were available for follow-up at 12 months. Of the eyes in the low hyperopia group, 92% were within +/- 0.50 D of the refractive goal. For the moderate sphere group and the high hyperopia/toric group, 79% and 71% of eyes, respectively, were within +/- 0.50 D of the refractive goal. No eye lost > or = 2 lines of BSCVA. An increase in higher order aberrations was noted in the high hyperopia/toric group from 0.47 microm (+/- 0.096) to 0.94 microm (+/- 0.167) (P < .001). No significant changes in higher order aberrations were noted in the low and moderate hyperopia groups. CONCLUSIONS Hyperopic LASIK using the WaveLight ALLEGRETTO WAVE excimer laser appears to be safe and effective in the correction of low, moderate, and high hyperopia and hyperopic astigmatism.
Collapse
Affiliation(s)
- A John Kanellopoulos
- Department of Ophthalmology, Manhattan Eye, Ear and Throat Hospital, New York, NY, USA.
| | | | | |
Collapse
|
21
|
Gailitis RP. Comparison of LASIK Outcomes With the Alcon LADARVision4000 and the VISX STAR S2 Excimer Lasers Using Optimized Nomograms. J Refract Surg 2005; 21:683-90. [PMID: 16329359 DOI: 10.3928/1081-597x-20051101-05] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the difference in clinical outcomes between LASIK patients treated with the Alcon LADARVision4000 laser and the VISX STAR S2 laser using optimized nomograms. METHODS Data from 572 LASIK surgeries of two groups that were sequentially performed by one surgeon were retrospectively reviewed. The first group of 286 eyes were the last cases performed with the VISX STAR S2 laser. Following these surgeries, a second group of 286 eyes were the first cases performed with the Alcon LADARVision4000 laser, after an initial 50-eye adaptation period. Treatments were guided by the Refractive Surgery Consultant software. RESULTS For myopic eyes 3 months postoperatively, the percentage of eyes with uncorrected visual acuity (UCVA) > or = 20/20, accuracy of treatment within +/- 0.5 D, and loss of > or = 2 lines of best spectacle-corrected visual acuity (BSCVA) for the LADARVision4000 and STAR S2, respectively was: 89% vs 63%, 84% vs 80%, and 0.8% vs 3.8%. For hyperopic eyes 3 months postoperatively, the percentage of eyes with UCVA > or = 20/20, accuracy of treatment within +/- 0.5 D, and loss of > or = 2 lines of BSCVA for the LADARVision4000 and STAR S2, respectively was: 74% vs 33%, 69% vs 74%, and 2% vs 18.5%. CONCLUSIONS Although good results are evident for both platforms, superior results were observed with the Alcon LADARVision4000 laser.
Collapse
|
22
|
Jin GJC, Merkley KH, Lyle WA. Laser in situ keratomileusis for primary and secondary mixed astigmatism. Am J Ophthalmol 2005; 139:1019-27. [PMID: 15953431 DOI: 10.1016/j.ajo.2005.01.048] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2004] [Revised: 01/26/2005] [Accepted: 01/29/2005] [Indexed: 11/29/2022]
Abstract
PURPOSE To evaluate and compare the efficacy, predictability, and safety of LASIK in the correction of primary and secondary mixed astigmatism after previous LASIK surgery. DESIGN Retrospective, comparative case series. METHODS The retrospective study included 118 eyes having LASIK with the LADARVison 4000 excimer laser (Alcon Surgical, Orlando, Florida) to correct mixed astigmatism. The eyes were divided into two groups: in group A (n = 64), LASIK was for primary mixed astigmatism and in group B (n = 54), LASIK was for secondary mixed astigmatism. Mean follow-up was 10.6 +/- 5.90 months. RESULTS Overall, the postoperative UCVA was 20/20 in 51% of eyes and 20/40 or better in 97% of eyes at the last visit. The mean refractive cylinder was -2.18 +/- 0.94 D preoperatively and -0.56 +/- 0.56 D postoperatively. Sixty-one percent of eyes had a refractive cylinder of 0.50 D or less. One eye lost 2 lines of BSCVA (0.8%). None of the eyes had postoperative BSCVA worse than 20/25. The difference of preoperative cylinder was significant between group A and group B (P = .000). However, there was no statistical difference of postoperative refraction and UCVA between these two groups. At 12 months, the mean vector magnitude achieved was 93% of intended cylinder correction with a mean angle of error of -3.0 +/- 16 degrees. CONCLUSIONS LASIK is a safe, effective, and predictable procedure to treat both primary and secondary mixed astigmatism. Nomogram adjustment with spherical and astigmatism components individually may improve refractive outcomes.
Collapse
Affiliation(s)
- George J C Jin
- The Eye Institute of Utah, 755 East 3900 South, Salt Lake City, UT 84107, USA.
| | | | | |
Collapse
|
23
|
O'Brart DPS, Patsoura E, Jaycock P, Rajan M, Marshall J. Excimer laser photorefractive keratectomy for hyperopia: 7.5-year follow-up. J Cataract Refract Surg 2005; 31:1104-13. [PMID: 16039483 DOI: 10.1016/j.jcrs.2004.10.051] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/13/2004] [Indexed: 11/21/2022]
Abstract
PURPOSE To report the results of a long-term prospective study to evaluate refractive stability and safety of hyperopic photorefractive keratectomy (H-PRK). SETTING Department of Ophthalmology, St. Thomas' Hospital, London, United Kingdom. METHODS Twenty-one patients (49%) (40 eyes) of cohort of 43 patients who participated in 1 of the first clinical trials of H-PRK were assessed at a mean follow-up of 90.7 months (range 62 to 106 months). The H-PRK was performed using a Summit Technology Apex Plus Excimer laser (Summit Technology, Inc.). The mean preoperative spherical equivalent refraction (SEQ) was +4.70 diopters (D) (range +2.00 to +7.50 D). Patients were allocated to 1 of 4 treatment groups based on their preoperative refraction and received 1 of the following spherical corrections: +1.50 D, +3.00 D, +4.50 D, or +6.00 D. RESULTS At 7.5 years, the refractive correction remained stable with a mean difference in SEQ between 1 year and 7.5 years of +0.28 D. The mean manifest SEQ was +0.83 D (range +5.00 to -3.00 D). Sixty-seven percent of eyes having corrections of +1.50 D and +3.00 D were within +/-1.00 D of the predicted correction. Predictability was poorer with +4.50 D and +6.00 D corrections, with 40% of eyes within +/-1.00 D of that expected. An improvement in uncorrected near acuity was achieved in 35 eyes (87.5%), and 35 eyes (87.5%) showed an improvement in uncorrected distance acuity from preoperative levels. Best spectacle-corrected visual acuity (BSCVA) was unchanged or improved from preoperative values in 25 eyes (62.5%). Three eyes (8%) lost 2 lines of Snellen BSCVA, which in 2 cases was attributable to cataract formation. A peripheral ring of haze, 6.5 mm in diameter, appeared in most eyes. Its intensity was greatest at 6 months and then diminished with time. In 10 eyes (25%), remnants of the haze ring were evident at 7.5 years and subepithelial iron rings, 6.5 mm in diameter were evident in 26 eyes (70%). No patient complained of night-vision problems and no eye developed ectasia. CONCLUSIONS In H-PRK, refractive stability achieved at 1 year was maintained up to 7.5 years with no evidence of hyperopic shift, diurnal fluctuation, or late regression. Peripheral corneal haze decreased with time but was still evident in a number of eyes at the last follow-up visit.
Collapse
Affiliation(s)
- David P S O'Brart
- Department of Ophthalmology, St. Thomas' Hospital, London SE1 7EH, UK.
| | | | | | | | | |
Collapse
|
24
|
Jaycock PD, O'Brart DPS, Rajan MS, Marshall J. 5-year follow-up of LASIK for hyperopia. Ophthalmology 2005; 112:191-9. [PMID: 15691550 DOI: 10.1016/j.ophtha.2004.09.017] [Citation(s) in RCA: 96] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2004] [Accepted: 09/02/2004] [Indexed: 11/19/2022] Open
Abstract
PURPOSE To assess the long-term efficacy and stability of LASIK for hyperopia (+0.75 to +7.00 diopters [D]). DESIGN Retrospective follow-up study of a previous phase III multicenter clinical trial (unpublished data). PARTICIPANTS Patients who had been treated for hyperopia (33 individuals, 47 eyes) attended follow-up 5 years after surgery. The preoperative mean spherical equivalent at the spectacle plane was +3.58 D (range, +0.75 to 7.00 D), and the attempted mean spherical correction at the corneal plane was +3.18 D (range, +1.00 to +6.00 D). INTERVENTION Treatments were performed using a Moria LSK One microkeratome and a Summit Technology SVS Apex Plus excimer laser fitted with an Axicon. MAIN OUTCOME MEASURES Manifest refraction, uncorrected visual acuity, best spectacle-corrected visual acuity, corneal transparency, complications, and patient satisfaction were recorded. RESULTS At 5 years, for treatments between +1.00 to +3.00 D, 71.0% of eyes were within +/-1.00 D of the intended correction, and for treatments between +3.5 to +6.0 D, 37.5% of eyes were within +/-1.00 D of intended correction. From 12 to 54 months after surgery for all patients, there was a hyperopic shift of +0.53 D (range, -0.13 to +3.13 D), with 51.1% of eyes experiencing an increase of +0.50 D or more and 27.7% of eyes showing a hyperopic shift of more than +1.00 D. This hyperopic shift was +0.67 D (range, 0 to +1.125 D) for patients younger than 40 years of age and +0.44 D (range, -1.33 to +1.50 D) for patients between 43 and 55 years of age. CONCLUSIONS LASIK was moderately effective for the correction of low degrees of hyperopia. However, there was regression throughout the 5-year follow-up that was greater than would be expected as a result of aging. Long-term stability of hyperopic LASIK refractive corrections, therefore, is uncertain.
Collapse
Affiliation(s)
- Philip D Jaycock
- Rayne Institute, Department of Ophthalmology, St. Thomas' Hospital, London, United Kingdom
| | | | | | | |
Collapse
|
25
|
Qazi MA, Roberts CJ, Mahmoud AM, Pepose JS. Topographic and biomechanical differences between hyperopic and myopic laser in situ keratomileusis. J Cataract Refract Surg 2005; 31:48-60. [PMID: 15721696 DOI: 10.1016/j.jcrs.2004.10.043] [Citation(s) in RCA: 64] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/05/2004] [Indexed: 11/16/2022]
Abstract
PURPOSE To evaluate the size, shape, and uniformity of the videokeratographic functional optical zone (FOZ) after laser in situ keratomileusis (LASIK) in 2 cohorts of patients with equivalent amounts of preoperative myopic or hyperopic astigmatism. SETTING Pepose Vision Institute, St. Louis, Missouri, USA. METHODS Eyes with myopic or hyperopic astigmatism (n=27 in each group) that had LASIK with the Visx Star S3 laser were retrospectively selected to match for level of preoperative refractive error. Slit-scanning videokeratography was performed preoperatively and 6 months postoperatively and analyzed using custom software. The FOZ was calculated by analyzing refractive power maps using a region-growing algorithm. Difference maps were generated from slit images and compared for interval change in corneal elevation, tangential curvature, and refractive power. The difference maps were also averaged (mean difference maps) for each target population. A Zernike decomposition of corneal first-surface elevation was performed to compare postoperative values with baseline parameters. RESULTS The mean postoperative refractive sphere at 6 months was -0.17 diopter (D) +/- 0.66 (SD) and +0.25 +/- 0.85 D in the myopia group and hyperopia group, respectively, and the mean postoperative astigmatism, -0.49 +/- 0.32 D and -0.65 +/- 0.52 D, respectively (P=.11). Based on the refractive power maps, the mean preoperative and postoperative myopic FOZ was 33.09 +/- 7.30 mm(2) and 30.94 +/- 5.43 mm(2), respectively, and the mean hyperopic FOZ, 33.19 +/- 7.96 mm(2) and 37.99 +/- 6.88 mm(2), respectively. After LASIK, there was an increase in magnitude of negative anterior corneal surface spherical-like Zernike values in the myopia group (P<.0001) and an increase in magnitude of positive spherical-like Zernike values in the hyperopia group. Postoperatively, significant induction of corneal surface horizontal coma was noted in hyperopic eyes (P<.0001). Hyperopic eyes, on average, had larger topographic FOZs after LASIK, but with less uniformity of curvature and power change than myopic eyes. CONCLUSIONS Hyperopic LASIK, which involves more transition points along the ablation diameter, produced a less uniform topographic FOZ than typical myopic treatments. Less predictable biomechanical changes from the circumferential release of tension on collagen bundles after midperipheral hyperopic ablation and greater variation in beam centration and the angle of incidence may contribute to the greater variability in corneal curvature and power in hyperopic LASIK than in myopic LASIK.
Collapse
Affiliation(s)
- Mujtaba A Qazi
- Pepose Vision Institute and the Department of Ophthalmology and Visual Sciences, Washington University School of Medicine, St. Louis, Missouri, USA
| | | | | | | |
Collapse
|
26
|
Abstract
PURPOSE To provide 6-month results of a 1-year clinical trial evaluating conductive keratoplasty (CK) for the treatment of presbyopic symptoms in emmetropic and hyperopic eyes. METHODS A total of 143 patients with presbyopic symptoms were enrolled in this 1-year United States FDA clinical trial and treated to improve near vision in 1 eye (unilateral treatment). In addition, 33 fellow eyes were treated to improve distance vision (bilateral treatment). For near vision correction, the target refraction was up to -2.0 D in the nondominant eye, and for distance vision correction, 0.0 D. Enrolled patients had a preoperative spherical equivalent of plano to +2.00 D, no more than 0.75 D of refractive astigmatism, and were 40 years of age or older. No retreatments were performed. RESULTS Of the eyes treated for near, 77% had uncorrected near vision of J3 or better at 6 months postoperatively. A total of 85% of all patients had binocular distance UCVA of 20/25 or better along with J3 or better near, a combination that represents functional acuity for a presbyope. Sixty-six percent of eyes treated for near had a manifest refractive spherical equivalent (MRSE) within +/- 0.50 D of intended at 6 months. In 89% of eyes, the MRSE changed 0.05 D or less between 3 and 6 months postoperatively. After month 1, the incidence of variables associated with safety was 1% or lower. Seventy-six percent were very satisfied or satisfied with their procedure. CONCLUSIONS CK appears to be very safe and effective in producing functional visual acuity in presbyopic eyes up to 6 months following the procedure. Patient satisfaction with the procedure is similar to that of monovision LASIK.
Collapse
|
27
|
Laser literature watch. Photomed Laser Surg 2004; 22:261-76. [PMID: 15315736 DOI: 10.1089/1549541041438588] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
28
|
Abstract
PURPOSE The purpose of this article is to review the literature and find characteristics that lead to improved patient satisfaction and better quality of vision. RECENT FINDINGS Flatter preoperative corneal curvature is a risk factor for starbursts after laser-assisted in situ keratomileusis (LASIK). Pupil size has not been found to be correlated with night vision symptoms. Wavefront-guided ablations reduce higher-order aberrations in comparison with traditional LASIK. Night vision symptoms are correlated with younger age, greater correction/increased ablation depth, enhancement, and decreased ablation diameter. Contrast sensitivity has been found to initially decrease after LASIK, returning to baseline 6 to 12 months postoperatively. SUMMARY LASIK has quickly become the refractive procedure of choice around the world. Quality of vision and patient satisfaction after LASIK can be difficult to assess because of the many variables that must be considered to accurately measure these endpoints. Preoperative characteristics such as: increased patient age, decreased corneal toricity, or increased pupil size reduce patient satisfaction. Intraoperative factors like decentration, ablation-zone size, active eye tracking, and wavefront guided ablations affect quality of vision. Finally, postoperative factors such as night vision symptoms, reduced contrast sensitivity, and re-treatment can lead to a decline in patient satisfaction. Eliminating or limiting these variables may lead to increased patient satisfaction and higher quality of vision after LASIK.
Collapse
Affiliation(s)
- Stephen D Hammond
- Department of Ophthalmology, Medical College of Georgia, Augusta, Georgia, USA
| | | | | |
Collapse
|
29
|
|