1
|
McDonald M, Janik SB, Bowden FW, Chokshi A, Singer MA, Tighe S, Mead OG, Nanda S, Qazi MA, Dierker D, Shupe AT, McMurren BJ. Association of Treatment Duration and Clinical Outcomes in Dry Eye Treatment with Sutureless Cryopreserved Amniotic Membrane. Clin Ophthalmol 2023; 17:2697-2703. [PMID: 37720008 PMCID: PMC10505017 DOI: 10.2147/opth.s423040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Accepted: 08/22/2023] [Indexed: 09/19/2023] Open
Abstract
Background While sutureless, cryopreserved amniotic membrane (cAM) has been shown to significantly improve signs and symptoms of dry eye disease (DED), no studies have assessed the association of cAM treatment duration to the differential response in clinical outcomes. Methods A multi-center, retrospective study was conducted on patients with moderate-to-severe DED who were treated with self-retained cAM (Prokera® Slim) for 2 to 7 days. The primary outcome measure was DEWS severity score assessed at 1 week, 1 month, and 3 months. Secondary outcome measures included ocular discomfort, visual symptoms, corneal staining, and visual acuity. Results A total of 89 eyes (77 patients) with moderate-to-severe DED (DEWS severity 3.24 ± 0.56) received treatment with self-retained cAM for 2 days (n = 10), 3 days (n = 15), 4 days (n = 12), 5 days (n = 19), 6 days (n = 6), or 7 days (n = 27). DEWS scores significantly improved at 1 week, 1 month, and 3 months for all treatment duration groups, with no significant difference observed between groups at any timepoint. In addition to an improvement in DEWS severity scores, those receiving cAM treatment for 2 days demonstrated a significant improvement in corneal staining, visual symptoms, and ocular discomfort at 1 week, 1 month, and 3 months. Conclusion This retrospective study suggests that a single placement of self-retained cAM for 2 days can significantly improve signs and symptoms of DED with a lasting benefit observed for up to 3 months.
Collapse
Affiliation(s)
| | | | | | | | | | - Sean Tighe
- BioTissue Holdings, Inc, Miami, FL, USA
- Florida International University Herbert Wertheim College of Medicine, Miami, FL, USA
| | | | - Seema Nanda
- Nanda Dry Eye & Vision Institute, Houston, TX, USA
| | | | | | | | | |
Collapse
|
2
|
Hashmani N, Hashmani M, Hashmani S, Fatima K, Farid N, Zakaria F, Qazi MA. The Influence of Tomographic Corneal Characteristics on Epithelial Thickness Profile. Cureus 2020; 12:e11731. [PMID: 33403163 PMCID: PMC7773304 DOI: 10.7759/cureus.11731] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Purpose To understand the influence of tomographic corneal characteristics on the epithelium of normal eyes. Methods We scanned a total of 98 eyes of 98 individuals using anterior segment tomography and a spectral-domain optical coherence tomography (OCT) epithelial mapping tool. Only eyes with no previous pathology were included, with a refractive range of +5 diopters (D) to -6 D, intraocular pressure of < 22 mmHg, and no evidence of dry eye (Schirmer’s test 2 value > 5 mm). Corneal curvature metrics were statistically correlated with regional epithelial thickness parameters. Results The anterior and posterior corneal surface flat and steep axis, the maximum and minimum curvature, corneal topographic astigmatism, astigmatism polar values, and corneal volume had no statistically significant correlation (p>0.05) with the epithelial thickness. Similarly, anterior corneal surface asphericity had no significant correlation. Posterior surface asphericity had a statistically significant moderate correlation with the epithelium in all areas. Similar results were seen in the multivariate analysis. Conclusions None of the front or back surface parameters had any influence on the corneal epithelium except for the posterior surface asphericity. This statistically significant yet clinically insignificant correlation may be enhanced in diseased populations like keratoconus and could indicate epithelial remodeling with early posterior corneal changes.
Collapse
Affiliation(s)
- Nauman Hashmani
- Ophthalmology and Visual Sciences, Hashmanis Hospital, Karachi, PAK
| | - Maria Hashmani
- Oral and Maxillofacial Surgery, Darul Sehat Hospital, Karachi, PAK
| | - Sharif Hashmani
- Ophthalmology and Visual Sciences, Hashmanis Hospital, Karachi, PAK
| | - Kiran Fatima
- Ophthalmology and Visual Sciences, Hashmanis Hospital, Karachi, PAK
| | - Neha Farid
- Ophthalmology and Visual Sciences, Hashmanis Hospital, Karachi, PAK
| | - Faiza Zakaria
- Ophthalmology, Dow Medical College, Dow University of Health Sciences, Karachi, PAK
| | | |
Collapse
|
3
|
Zafar AB, Chu RC, Bishara MN, Qazi MA, Mahmoud AM, Pepose JS. <p>Objective Quantification of Image Quality and Optical Scatter Before and After Nd:YAG Capsulotomy Using a Double-Pass Technique</p>. Clin Ophthalmol 2020; 14:1403-1411. [PMID: 32546948 PMCID: PMC7266399 DOI: 10.2147/opth.s248286] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Purpose The purpose of this study is to evaluate and compare the correlation between changes in vision and HD Analyzer dual-pass metrics versus changes in vision and conventional subjective slit lamp gradings in pseudophakic patients with posterior capsular opacity undergoing neodymium:yttrium-aluminum-garnet (Nd:YAG) capsulotomy. Patients and Methods High contrast (HC) and low contrast (LC) best spectacle-corrected distance visual acuity (BCVA) and HD Analyzer evaluation were prospectively performed on patients with mild-to-moderate posterior capsular opacification (PCO) and monofocal and accommodating intraocular lens implants. Differences between pre- and post-operative measurements were calculated, along with the correlation of HD Analyzer metrics and slit lamp grading to changes in visual acuity. Results Following Nd:YAG capsulotomy (n=29), there was statistically significant improvement in HC-BCVA and LC-BCVA, decrease in optical scatter, and corresponding improvement in Strehl ratio and HD Analyzer values at all contrast levels tested (p≤0.05). Pearson test showed a high correlation between the improvement in HC-BCVA (r coefficient = 0.78) and LC-BCVA (r coefficient = 0.71) to the improvement in Objective Scatter Index (OSI). There was a higher correlation of change in HC-BCVA to pre-op OSI (r2=0.61) than to the subjective PCO grading score (r2 = 0.19). There was also a higher correlation of change in LC-BCVA to pre-op OSI (r2 = 0.49) than to subjective grading (r2 = 0.16). Conclusion The HD Analyzer provides objective measurements of forward light scatter (ie, light directed towards the retina) that can assist with both PCO grading and prediction of improvement of visual quality after YAG laser capsulotomy with higher accuracy than conventional slit lamp assessment based upon backscatter (ie, light traveling to the observer) in patients tested with monofocal and accommodating intraocular lens implants.
Collapse
Affiliation(s)
- Abu-Bakar Zafar
- Department of Ophthalmology, Carle Foundation Hospital, Champaign, IL, USA
| | | | | | - Mujtaba A Qazi
- Pepose Vision Institute, St. Louis, MO, USA
- Department of Ophthalmology and Visual Sciences, Washington University School of Medicine, St. Louis, MO, USA
| | - Ashraf M Mahmoud
- Department of Ophthalmology, Ohio State University, Columbus, OH, USA
| | - Jay S Pepose
- Pepose Vision Institute, St. Louis, MO, USA
- Department of Ophthalmology and Visual Sciences, Washington University School of Medicine, St. Louis, MO, USA
- Correspondence: Jay S Pepose Pepose Vision Institute, 1815 Clarkson Road, Chesterfield, MO63107, USA Email
| |
Collapse
|
4
|
Pepose JS, Qazi MA, Devries DK. Longitudinal changes in dry eye symptoms and signs following lifitegrast therapy and relationship to tear osmolarity. Clin Ophthalmol 2019; 13:571-579. [PMID: 30992657 PMCID: PMC6445190 DOI: 10.2147/opth.s196593] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
Background This study measured longitudinal changes in dry eye disease (DED) symptoms and signs following lifitegrast therapy and assessed their relationship to tear osmolarity to test the hypothesis that a decline in tear osmolarity is a reliable leading indicator of subsequent improvement in DED symptoms and signs after initiating lifitegrast treatment. Methods This phase IV, prospective, single-arm, open-label, 12-week study enrolled subjects aged ≥18 years with eye dryness score ≥40 (0–100 VAS) and tear osmolarity ≥308 mOsm/L. Subjects were prescribed lifitegrast ophthalmic solution 5%, twice daily in each eye. DED symptoms were assessed via VAS at baseline and 2, 6, and 12 weeks. Signs included tear osmolarity, meibomian gland dysfunction, tear breakup time, and fluorescein corneal staining. In post-hoc analysis, subjects with ≥5 mOsm/L decrease in osmolarity over 12 weeks were Responders. Results Of 26 subjects in the intent-to-treat population, 23 were female; mean age was 67.4 years. Baseline mean±SD eye dryness was 68.7±16.5 and tear osmolarity was 317.8±8.5 mOsm/L. All seven symptoms (dryness, burning, foreign body sensation, pain, photophobia, itching, blurred vision) declined significantly (P<0.01) from baseline to 6 and 12 weeks. Signs did not change significantly. For 13 Responders, tear osmolarity decreased from baseline to 12 weeks (319.2±8.5 to 300.6±12.3 mOsm/L, P<0.001) and corneal staining trended toward improvement (1.1±0.9 to 0.6±0.7, P=0.136). Among Nonresponders, osmolarity increased from 316.4+8.7 to 329.6+13.9 (P<0.01) and corneal staining showed no change (1.3±0.8 to 1.0±0.7 at 12 weeks, P=0.293). Conclusions Lifitegrast reduced DED symptoms among subjects with moderate-to-severe disease (severity defined by VAS for eye dryness). Potential reasons that may underlie the dichotomous effect of drug treatment on tear osmolarity are discussed.
Collapse
Affiliation(s)
| | - Mujtaba A Qazi
- Department of Ophthalmology and Visual Sciences, Washington University School of Medicine, St Louis, MO, USA
| | | |
Collapse
|
5
|
McDonald MB, Sheha H, Tighe S, Janik SB, Bowden FW, Chokshi AR, Singer MA, Nanda S, Qazi MA, Dierker D, Shupe AT, McMurren BJ. Treatment outcomes in the DRy Eye Amniotic Membrane (DREAM) study. Clin Ophthalmol 2018; 12:677-681. [PMID: 29670328 PMCID: PMC5898584 DOI: 10.2147/opth.s162203] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022] Open
Abstract
Purpose To evaluate the efficacy of cryopreserved amniotic membrane (CAM) in reducing signs and symptoms of dry eye disease (DED) in a large patient population. Methods A retrospective chart review at 10 clinical sites was done of patients with refractory DED who received CAM and completed at least 3 months of follow-up. Data collected were demographics; medical history including previous and current ocular treatment, diagnosis, clinical presentations, comorbidity, duration and frequency of treatment with CAM; and concomitant medications. The primary outcome was the change in dry eye workshop (DEWS) score after treatment. Results A total of 97 eyes of 84 patients exhibited severe dry eye despite maximal medical treatments including topical artificial tears, cyclosporine-A, serum, antibiotics, and steroids. Patients manifested with superficial punctate keratitis (86%), filamentary keratitis (13%), exposure keratitis (19%), neurotrophic keratitis (2%), and corneal epithelial defect (7%). After CAM treatment for 5.4±2.8 days, 74 (88%) patients demonstrated an improved ocular surface along with a notable reduction of the severity as the overall DEWS score was significantly reduced from 3.25±0.5 at baseline to 1.44±0.6 at 1 week, 1.45±0.6 at 1 month, and 1.47±0.6 at 3 months (p<0.001). Ten eyes (10%) required repeated treatment to complete healing. Apart from discomfort during CAM placement, there were no adverse events. Conclusion Placement of CAM is promising to enhance the recovery of ocular surface health and reduce signs and symptoms in patients with moderate-to-severe DED.
Collapse
Affiliation(s)
| | - Hosam Sheha
- Ocular Surface Center and TissueTech, Inc., Miami, FL, USA.,Florida International University Herbert Wertheim College of Medicine, Miami, FL, USA.,Hofstra University School of Medicine, Hempstead, NY, USA.,Research Institute of Ophthalmology, Cairo, Egypt
| | - Sean Tighe
- Ocular Surface Center and TissueTech, Inc., Miami, FL, USA.,Florida International University Herbert Wertheim College of Medicine, Miami, FL, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
6
|
Qazi MA, Vora P, Venugopal C, Sidhu SS, Moffat J, Swanton C, Singh SK. Intratumoral heterogeneity: pathways to treatment resistance and relapse in human glioblastoma. Ann Oncol 2018; 28:1448-1456. [PMID: 28407030 DOI: 10.1093/annonc/mdx169] [Citation(s) in RCA: 237] [Impact Index Per Article: 39.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2017] [Indexed: 01/01/2023] Open
Abstract
Intratumoral heterogeneity (ITH) has increasingly being described for multiple cancers as the root cause of therapy resistance. Recent studies have started to explore the scope of ITH in glioblastoma (GBM), a highly aggressive and fatal form of brain tumor, to explain its inevitable therapy resistance and disease relapse. In this review, we detail the emerging data that explores the extensive genetic, cellular and functional ITH present in GBM. We discuss current experimental models of human GBM recurrence and suggest harnessing new technologies (CRISPR-Cas9 screening, CyTOF, cellular barcoding, single cell analysis) to delineate GBM ITH and identify treatment-refractory cell populations, thus opening new therapeutic windows. We will also explore why current therapeutics have failed in clinical trials and how ITH can inform us on developing empiric therapies for the treatment of recurrent GBM.
Collapse
Affiliation(s)
- M A Qazi
- Stem Cell and Cancer Research Institute.,Department of Biochemistry and Biomedical Sciences
| | - P Vora
- Stem Cell and Cancer Research Institute.,Department of Surgery, McMaster University, Hamilton
| | - C Venugopal
- Stem Cell and Cancer Research Institute.,Department of Surgery, McMaster University, Hamilton
| | - S S Sidhu
- Donnelly Centre and Department of Molecular Genetics, University of Toronto, Toronto, Canada
| | - J Moffat
- Donnelly Centre and Department of Molecular Genetics, University of Toronto, Toronto, Canada
| | - C Swanton
- The Francis Crick Institute, University College London Institute, London, UK
| | - S K Singh
- Stem Cell and Cancer Research Institute.,Department of Biochemistry and Biomedical Sciences.,Department of Surgery, McMaster University, Hamilton
| |
Collapse
|
7
|
Pepose JS, Qazi MA, Chu R, Stahl J. A prospective randomized clinical evaluation of 3 presbyopia-correcting intraocular lenses after cataract extraction. Am J Ophthalmol 2014; 158:436-46.e1. [PMID: 24932989 DOI: 10.1016/j.ajo.2014.06.003] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2014] [Revised: 06/03/2014] [Accepted: 06/03/2014] [Indexed: 12/18/2022]
Abstract
PURPOSE To compare contrast sensitivity, visual acuity (VA), and halos in subjects bilaterally implanted with 1 of 3 FDA-approved presbyopia-correcting intraocular lenses. DESIGN Prospective, randomized, partially masked, multicenter clinical trial. METHODS Seventy-eight subjects were randomized sequentially for bilateral implantation with the Crystalens AO (Bausch & Lomb Surgical), AcrySof IQ ReSTOR +3.0 (Alcon Laboratories), or Tecnis Multifocal (Abbott Medical Optics) lenses. Subjects were evaluated through visit 4 (4 to 6 months after surgery) with the following monocular and binocular assessments: high- and low-contrast VA, contrast sensitivity without glare, halos or starbursts, defocus curves, optical scatter, retinal point spread function, and safety. RESULTS The Crystalens AO and ReSTOR +3.0 demonstrated better monocular and binocular contrast sensitivity without glare at low to mid spatial frequencies compared with the Tecnis Multifocal lens. Binocular uncorrected distance VA was not significantly different between the 3 lenses. The Crystalens AO had significantly better binocular low-contrast distance-corrected VA than the ReSTOR +3.0 and better mean monocular low-contrast DCVA than the Tecnis Multifocal lens. The Crystalens AO demonstrated significantly better monocular and binocular uncorrected and distance-corrected intermediate VA than the ReSTOR +3.0 or Tecnis Multifocal lenses. The ReSTOR+3.0 lens had significantly better monocular and binocular uncorrected and distance-corrected near VA tested at 40 cm compared with the Crystalens AO and Tecnis Multifocal lens. The Crystalens AO elicited significantly less halos than the Tecnis Multifocal lens and less optical scatter than the ReSTOR +3.0 or Tecnis Multifocal lens. CONCLUSIONS The Crystalens AO had statistically better uncorrected intermediate VA and distance-corrected intermediate VA than the ReSTOR +3.0 or Tecnis Multifocal lenses and fewer photic phenomenon than the Tecnis Multifocal lens. Both multifocals had better distance-corrected near VA and uncorrected near VA than the Crystalens AO. These findings may guide intraocular lens selection for individual patients seeking to optimize vision at specific vergences or lighting conditions.
Collapse
Affiliation(s)
- Jay S Pepose
- Pepose Vision Institute and the Department of Ophthalmology and Visual Sciences, Washington University School of Medicine, St. Louis, Missouri.
| | - Mujtaba A Qazi
- Pepose Vision Institute and the Department of Ophthalmology and Visual Sciences, Washington University School of Medicine, St. Louis, Missouri
| | | | | |
Collapse
|
8
|
Dubey AK, Dubey S, Handu SS, Qazi MA. Vismodegib: The first drug approved for advanced and metastatic basal cell carcinoma. J Postgrad Med 2013; 59:48-50. [DOI: 10.4103/0022-3859.109494] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
9
|
Pepose JS, Qazi MA, Davies J, Doane JF, Loden JC, Sivalingham V, Mahmoud AM. Visual performance of patients with bilateral vs combination Crystalens, ReZoom, and ReSTOR intraocular lens implants. Am J Ophthalmol 2007; 144:347-357. [PMID: 17651679 DOI: 10.1016/j.ajo.2007.05.036] [Citation(s) in RCA: 113] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2007] [Revised: 05/21/2007] [Accepted: 05/24/2007] [Indexed: 10/23/2022]
Abstract
PURPOSE To compare the visual performance of patients with bilateral vs combination Crystalens, ReZoom, and ReSTOR intraocular lens (IOLs) implants. DESIGN Prospective, nonrandomized study. METHODS Forty-nine patients were implanted with bilateral Crystalens (Eyeonics, Aliso Viejo, California, USA), ReSTOR (Alcon Laboratories, Fort Worth, Texas, USA), and ReZoom (American Medical Optics, Santa Clara, California, USA) or combined Crystalens and ReSTOR or Crystalens and ReZoom IOLs after phacoemulsification. Monocular and binocular testing four to six months after surgery included uncorrected and best-spectacle corrected visual acuity at distance, intermediate, and near vision; mesopic contrast sensitivity function with and without glare; and quality-of-life and vision surveys six months after surgery. RESULTS Monocular testing showed that eyes with Crystalens accommodating IOL had statistically better best-spectacle corrected distance, uncorrected and distance-corrected intermediate, and best-corrected near vision. Eyes with the ReSTOR multifocal IOL had better uncorrected near vision, required the lowest reading add, and had the lowest uncorrected and distance-corrected intermediate vision. Monocular mesopic contrast sensitivity with and without glare was better with the Crystalens IOL vs either multifocal IOL at specific spatial frequencies. The binocular subjective quality of vision and quality of life questionnaires were favorable for the bilateral Crystalens group. CONCLUSIONS Any combination of Crystalens in one or both eyes was better for intermediate vision. Any combination of ReSTOR in one or both eyes was better for near vision. The Crystalens and ReSTOR combination had better mean intermediate and near vision overall. A multifocal IOL in one or both eyes was associated with lower contrast sensitivity and more subjective reports of photic phenomena. The accommodating and multifocal IOL combinations elicited less night glare symptoms than in patients with either bilateral multifocal IOL, but more than with bilateral Crystalens implantation.
Collapse
Affiliation(s)
- Jay S Pepose
- Pepose Vision Institute, St Louis, Missouri 63017, USA.
| | | | | | | | | | | | | |
Collapse
|
10
|
Qazi MA, Roberts CJ, Cua IY, Pepose JS. Reply : Determining corneal power using Orbscan II videokeratography for IOL calculation after excimer laser surgery for myopia. J Cataract Refract Surg 2007. [DOI: 10.1016/j.jcrs.2007.06.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
11
|
Pepose JS, Feigenbaum SK, Qazi MA, Merchea M. Comparative performance of the Zyoptix XP and Hansatome zero-compression microkeratomes. J Cataract Refract Surg 2007; 33:1386-91. [PMID: 17662429 DOI: 10.1016/j.jcrs.2007.04.014] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2007] [Accepted: 04/03/2007] [Indexed: 10/23/2022]
Abstract
PURPOSE To compare flap parameters produced by the Zyoptix XP and Hansatome microkeratomes (both Bausch & Lomb) and to evaluate preoperative variables contributing to flap thickness variation. SETTING Private practice, St. Louis, Missouri, USA. METHODS Flap dimensions in 75 eyes that prospectively had laser in situ keratomileusis using the Zyoptix XP microkeratome were compared with a historical control sample of 75 eyes treated with the Hansatome microkeratome. The 2 groups were matched for mean keratometry, central corneal pachymetry, spherical equivalent (SE), age, and microkeratome head size and suction ring diameter. RESULTS The mean ultrasound-measured flap thickness was 126.54 microm +/- 14.6 (SD) and 143.74 +/- 15.0 microm for the 120 microm and 140 microm Zyoptix XP heads, respectively, and 128.90 +/- 20.4 microm and 143.32 +/- 21.0 microm for the 160 microm and 180 microm Hansatome heads, respectively. The standard deviation in flap thickness was smaller and statistically significant for the Zyoptix XP (+/-14.8 microm) versus the Hansatome (+/-20.7 microm) (P = .0039, F test). Preoperative pachymetry and SE (P<.001) accounted for 20% of the variability in measured flap thickness using the Hansatome. For the Zyoptix XP, preoperative pachymetry was statistically significant in explaining the variation in flap thickness with the 120 microm head (P = .02) but not with the 140 microm head. Variation in flap thickness from either Zyoptix XP head was not statistically related to the preoperative SE. CONCLUSION Although the 2 microkeratomes produced flaps of similar mean thickness, the Zyoptix XP showed significantly less variation in flap thickness than the Hansatome, was less affected by measurable preoperative variables such as SE, and was closer to nominal labeling.
Collapse
|
12
|
Qazi MA, Cua IY, Roberts CJ, Pepose JS. Determining corneal power using Orbscan II videokeratography for intraocular lens calculation after excimer laser surgery for myopia. J Cataract Refract Surg 2007; 33:21-30. [PMID: 17189789 DOI: 10.1016/j.jcrs.2006.08.026] [Citation(s) in RCA: 59] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2006] [Accepted: 08/13/2006] [Indexed: 11/27/2022]
Abstract
PURPOSE To assess the accuracy of Orbscan II slit-scanning videokeratography for intraocular lens (IOL) calculation in eyes with previous photorefractive surgery for myopia. SETTING Private practice, St. Louis, Missouri, USA. METHODS Corneal power (K) was measured by manual keratometry, Placido-based videokeratography (Atlas), slit-scanning videokeratography (Orbscan II), and contact lens overrefraction in 21 post-photoablation eyes having cataract surgery. Postoperative data collected after phacoemulsification were used to back-calculate corneal power (BCK). The BCK values were statistically compared at 3.0 to 6.0 mm central Orbscan II curvature and power measurements, including total axial power, total tangential power, total mean power, and total optical power. Similar comparisons were made to Atlas curvature at the 0.0 to 10.0 mm zones. RESULTS The mean corneal power after refractive surgery based on BCK values using the Holladay 2 formula (BCK H2) was 39.35 diopters (D) +/- 2.58 (SD). The mean manual value (40.52 +/- 1.95 D) and Atlas-based values were statistically higher than BCK H2 values (P<.001). The mean corneal power calculated from historical data was 39.33 +/- 2.70 D (P = .83 to BCK H2; n = 19) and from contact lens overrefraction, 41.38 +/- 3.11 D (P = .19; n = 5). Orbscan II parameters (n = 21) of the total mean power (3.0 mm, 39.10 +/- 2.63 D), total tangential power (3.0 mm, 39.11 +/- 2.60), total axial power (5.0 mm, 39.19 +/- 2.55 D), and total optical power (3.0 mm, 39.08 +/- 2.78 D; 4.0 mm, 39.39 +/- 2.76 D) were statistically similar to both the historical and BCK H2 values (P>.11). If used prospectively, 80.9% of eyes would have been within +/-0.50 D of the targeted refraction using a 4.0 mm total optical power, 76.2% using a 5.0 mm total axial power, and 42.1% using the historical method. CONCLUSION The Orbscan II 5.0 mm total axial power and 4.0 mm total optical power can be used to more accurately predict true corneal power than the history-based method and may be particularly useful when pre-LASIK data are unavailable.
Collapse
Affiliation(s)
- Mujtaba A Qazi
- Department of Ophthalmology and Visual Sciences, Washington University School of Medicine, St. Louis, Missouri, USA
| | | | | | | |
Collapse
|
13
|
Pepose JS, Feigenbaum SK, Qazi MA, Sanderson JP, Roberts CJ. Changes in corneal biomechanics and intraocular pressure following LASIK using static, dynamic, and noncontact tonometry. Am J Ophthalmol 2007; 143:39-47. [PMID: 17188041 DOI: 10.1016/j.ajo.2006.09.036] [Citation(s) in RCA: 253] [Impact Index Per Article: 14.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2006] [Revised: 09/08/2006] [Accepted: 09/12/2006] [Indexed: 11/28/2022]
Abstract
PURPOSE To compare the preoperative and postoperative measurement of corneal biomechanical properties and intraocular pressure (IOP) using Goldmann applanation tonometry (GAT), the ocular response analyzer (ORA), and the Pascal dynamic contour tonometer (PDCT) in eyes undergoing myopic laser in situ keratomileusis (LASIK). DESIGN Prospective, nonrandomized clinical trial. METHODS IOP was measured in 66 myopic eyes before and after LASIK by GAT, ORA, and PDCT in a randomized sequence. Metrics of corneal biomechanical properties (corneal hysteresis [CH], corneal resistance factor [CRF], and ocular pulse amplitude [OPA]) were recorded. RESULTS After LASIK, there was a reduction in mean corneal pachymetry of 90.2 mum and in IOP measurements with GAT (Delta = -1.8 +/- 2.8 mm Hg; P < .01), ORA-Goldmann (Delta = -4.6 +/- 2.8 mm Hg, P < .01), and ORA-corneal compensated (Delta - 2.1 +/- 2.6 mm Hg; P < .05). However, there was no statistically significant difference between preoperative and postoperative IOP measurements taken by PDCT (Delta = -0.5 +/- 2.6 mm Hg). Postoperatively, CRF decreased by 28.6% (P < .01), CH by 16.2% (P < .01), and OPA by 1.8% (P = .32). CONCLUSIONS Measurement of IOP with PDCT appears to be relatively immune to changes in corneal biomechanics and pachymetry after LASIK, in comparison to GAT and ORA measures of IOP. PDCT and ORA both showed statistically lower variation in measurement than GAT. LASIK produced a marked decline in CH and CRF, which may reflect respective changes in the viscous and elastic qualities of the post-LASIK cornea. In contrast, there was no statistical change in OPA.
Collapse
Affiliation(s)
- Jay S Pepose
- Pepose Vision Institute, 16216 Baxter Road, Chesterfield, MO 63017, USA.
| | | | | | | | | |
Collapse
|
14
|
Qazi MA, Johnson TW, Pepose JS. Development of late-onset subepithelial corneal haze after laser-assisted subepithelial keratectomy with prophylactic intraoperative mitomycin-C. J Cataract Refract Surg 2006; 32:1573-8. [PMID: 16931277 DOI: 10.1016/j.jcrs.2006.04.027] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2006] [Accepted: 04/05/2006] [Indexed: 01/18/2023]
Abstract
We present a case of dense, visually significant reticular haze that developed approximately 17 months after uneventful laser-assisted subepithelial keratectomy with mitomycin-C (MMC). The patient was successfully treated with manual debridement coupled with phototherapeutic keratectomy and intraoperative MMC.
Collapse
Affiliation(s)
- Mujtaba A Qazi
- Pepose Vision Institute, Washington University School of Medicine, St. Louis, Missouri, USA
| | | | | |
Collapse
|
15
|
Qazi MA, Roberts CJ, Mahmoud AM, Pepose JS. Topographic and biomechanical differences between hyperopic and myopic laser in situ keratomileusis. J Cataract Refract Surg 2005; 31:48-60. [PMID: 15721696 DOI: 10.1016/j.jcrs.2004.10.043] [Citation(s) in RCA: 64] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/05/2004] [Indexed: 11/16/2022]
Abstract
PURPOSE To evaluate the size, shape, and uniformity of the videokeratographic functional optical zone (FOZ) after laser in situ keratomileusis (LASIK) in 2 cohorts of patients with equivalent amounts of preoperative myopic or hyperopic astigmatism. SETTING Pepose Vision Institute, St. Louis, Missouri, USA. METHODS Eyes with myopic or hyperopic astigmatism (n=27 in each group) that had LASIK with the Visx Star S3 laser were retrospectively selected to match for level of preoperative refractive error. Slit-scanning videokeratography was performed preoperatively and 6 months postoperatively and analyzed using custom software. The FOZ was calculated by analyzing refractive power maps using a region-growing algorithm. Difference maps were generated from slit images and compared for interval change in corneal elevation, tangential curvature, and refractive power. The difference maps were also averaged (mean difference maps) for each target population. A Zernike decomposition of corneal first-surface elevation was performed to compare postoperative values with baseline parameters. RESULTS The mean postoperative refractive sphere at 6 months was -0.17 diopter (D) +/- 0.66 (SD) and +0.25 +/- 0.85 D in the myopia group and hyperopia group, respectively, and the mean postoperative astigmatism, -0.49 +/- 0.32 D and -0.65 +/- 0.52 D, respectively (P=.11). Based on the refractive power maps, the mean preoperative and postoperative myopic FOZ was 33.09 +/- 7.30 mm(2) and 30.94 +/- 5.43 mm(2), respectively, and the mean hyperopic FOZ, 33.19 +/- 7.96 mm(2) and 37.99 +/- 6.88 mm(2), respectively. After LASIK, there was an increase in magnitude of negative anterior corneal surface spherical-like Zernike values in the myopia group (P<.0001) and an increase in magnitude of positive spherical-like Zernike values in the hyperopia group. Postoperatively, significant induction of corneal surface horizontal coma was noted in hyperopic eyes (P<.0001). Hyperopic eyes, on average, had larger topographic FOZs after LASIK, but with less uniformity of curvature and power change than myopic eyes. CONCLUSIONS Hyperopic LASIK, which involves more transition points along the ablation diameter, produced a less uniform topographic FOZ than typical myopic treatments. Less predictable biomechanical changes from the circumferential release of tension on collagen bundles after midperipheral hyperopic ablation and greater variation in beam centration and the angle of incidence may contribute to the greater variability in corneal curvature and power in hyperopic LASIK than in myopic LASIK.
Collapse
Affiliation(s)
- Mujtaba A Qazi
- Pepose Vision Institute and the Department of Ophthalmology and Visual Sciences, Washington University School of Medicine, St. Louis, Missouri, USA
| | | | | | | |
Collapse
|
16
|
Mirza MA, Qazi MA, Pepose JS. Treatment of dense subepithelial corneal haze after laser-assisted subepithelial keratectomy. J Cataract Refract Surg 2004; 30:709-14. [PMID: 15050273 DOI: 10.1016/s0886-3350(03)00521-2] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/21/2003] [Indexed: 11/18/2022]
Abstract
We report a case of dense and visually significant corneal haze after laser-assisted subepithelial keratectomy (LASEK). Visually significant corneal haze after LASEK can be successfully treated with manual debridement and intraoperative mitomycin-C.
Collapse
|
17
|
Huang B, Mirza MA, Qazi MA, Pepose JS. The effect of punctal occlusion on wavefront aberrations in dry eye patients after laser in situ keratomileusis. Am J Ophthalmol 2004; 137:52-61. [PMID: 14700644 DOI: 10.1016/s0002-9394(03)00903-6] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
PURPOSE To compare the wavefront aberrations in post-laser in situ keratomileusis (LASIK) dry eye patients before and after punctal occlusion. DESIGN Prospective, comparative, nonrandomized study. METHODS Wavefront aberrometry was performed on 16 eyes of eight patients with dry eyes after LASIK surgery. Wavefront measurements were taken before and 1 month after punctal plug placement and compared with 10 eyes of post-LASIK patients without clinically dry eyes measured twice 1 month apart. Student t tests were used to assess the statistical significance of differences between pre- and post-punctal plug measurements. RESULTS Punctal occlusion in the post-LASIK dry eye patients significantly reduced total, lower, and higher order wavefront aberrations by 47% to 63% (P <.01). Among higher-order aberrations, there were significant reductions in coma and spherical aberration but not in trefoil, after punctal occlusion. The reduction of wavefront aberrations by punctal occlusion in post-LASIK dry eye patients resulted in a significant improvement in quantitative visual acuity assessed using an Early Treatment of Diabetic Retinopathy Study chart and in subjective qualitative vision, confirmed by convolutional analysis using image simulation. No statistically significant differences in any of these metrics were found in the post-LASIK control group without clinically dry eyes measured twice at a similar time interval. CONCLUSIONS Wavefront aberrometry provides a useful, objective assessment of post-LASIK dry eye patients before and after punctal plug placement. Aggressive treatment of dry eyes may be important before obtaining wavefront measurements that serve as the basis for planning refractive corneal laser treatments and retreatments.
Collapse
Affiliation(s)
- Bo Huang
- Pepose Vision Institute, St. Louis, Missouri, USA
| | | | | | | |
Collapse
|
18
|
Abstract
PURPOSE To compare various methods of estimating corneal power for intraocular lens (IOL) calculation in patients with irregular corneal astigmatism. SETTING Pepose Vision Institute, St. Louis, Missouri, USA. Case reports and review of the medical literature. RESULTS Two patients with irregular corneal astigmatism had an IOL exchange after a "surprise" post-cataract-surgery refraction. In the first case, the patient had a post-cataract-surgery refraction of +5.50 -0.75 x 69 and in the second case, a refraction of -7.00 -1.00 x 180. The central corneal power before IOL exchange was assessed using manual keratometry, various computerized videokeratography curvature and power maps, and contact lens overrefraction. The total axial power map (Orbscan(R), Bausch & Lomb), total optical power map (Orbscan), and contact lens overrefraction method provided the most accurate estimates of central corneal power in these 2 patients. CONCLUSION Computerized scanning-slit videokeratography, which analyzes the anterior and posterior surfaces of the cornea, and the contact lens overrefraction method gave good estimations of corneal power in patients with irregular corneal astigmatism. This type of analysis may improve the accuracy of IOL calculation in patients with corneal pathology and irregular astigmatism.
Collapse
Affiliation(s)
- Irwin Y Cua
- Pepose Vision Institute, Chesterfield, Missouri, USA
| | | | | | | |
Collapse
|
19
|
Abstract
PURPOSE To assess the effects of scleral expansion band (SEB) segments on accommodative amplitude (primary measure), along with near and distance vision, refraction, pupil size and function, keratometry, axial length, intraocular pressure, contrast sensitivity, stereopsis, and other parameters (secondary measures) in a cohort of 29 emmetropic, presbyopic patients. DESIGN Multicenter, prospective, nonrandomized, unmasked clinical trial in which the nonoperated eye served as the control. METHODS Four polymethylmethacrylate segments were surgically implanted in quadrantic scleral pockets created in the dominant eye of 29 emmetropic patients who were between the ages of 51 and 60 (mean age 54). Patients were examined preoperatively and up to 6 months postoperatively. The aforementioned tests were performed on the operated and control eye of each patient. Data were analyzed using two-sided rank tests. Medians, means, and standard deviations are provided for all measurements. RESULTS Accommodative amplitude was measured monocularly using a near-point "push" technique from both a 70-cm and 30-cm starting point. An increase in accommodative amplitude of surgical eyes by +1.7 +/- 1.5 diopters and +1.5 +/- 1.2 diopters, at these two testing distances, respectively, was noted at 6 months postoperatively (P <.0001). A smaller increase was also seen in control eyes (+1.2 +/- 1.1 diopters and +1.3 +/- 1.2 diopters, respectively). There was notable intercenter variation in gains in accommodation, with three of seven centers showing significant improvement in near-point accommodative amplitudes relative to the others (P =.0003). There was a median improvement of uncorrected near acuity in surgical eyes by 0.3 logarithm of the minimal angle of resolution (logMAR) at 30 and 40 cm and by 4 lines at 20 cm, with the difference in near acuity improvement at 6 months between SEB eyes and control eyes statistically significant at 20 cm (P <.030). Changes in spherical equivalence, axial length, and central keratometry readings were not statistically significant. There were no reports of anterior segment ischemia or malignant glaucoma. Adverse effects were limited to a transient elevation of intraocular pressure in one patient and misalignment of individual SEB segments, due to inadequate scleral pocket formation, in three patients. Only one SEB segment in one eye was replaced. It appears that the thickness and uniformity of the scleral belt loop is critical to the proper positioning and efficacy of the SEB segments. CONCLUSION While the safety profile of SEB segments for the treatment of presbyopia was high, a modest improvement in near vision was noted in approximately half the patients using subjective methods of testing. The mechanisms that underlie improvement in near vision in the nonoperated eye await explanation. This may be due to a centrally controlled consensual response, potentiated convergence generating increased intravitreal pressure and hydraulic lift of the vitreo-zonular-lens diaphragm, or artifact from current testing techniques. Future studies of the SEB procedure should address the issue of intercenter variation by further standardizing and automating specific aspects of the surgical technique, as well as incorporating objective testing methods into the study design.
Collapse
Affiliation(s)
- Mujtaba A Qazi
- Pepose Vision Institute, Chesterfield, Missouri 63017, USA
| | | | | |
Collapse
|
20
|
Qazi MA, Senaldi G, Tacchini-Cottier F, Qazi MH, Hoessli DC, Walker-Nasir E. Galactose residues in Plasmodium falciparum glycoproteins: incorporation and elimination. Biochem Soc Trans 1994; 22:362S. [PMID: 7821615 DOI: 10.1042/bst022362s] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Affiliation(s)
- M A Qazi
- Dept. of Biology, Quaid-e-Azam University, Islamabad, Pakistan
| | | | | | | | | | | |
Collapse
|
21
|
Noble WE, Chaudhuri P, Qazi MA. Idiopathic long q-t syndrome: brief case report and discussion. W V Med J 1994; 90:143-144. [PMID: 8009871] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Idiopathic long q-t syndrome (LQTS) is an infrequently occurring familial disorder in which affected family members have an abnormally prolonged q-tc interval with syncope, ventricular arrythmias and sudden death. In this article, we present the case of a 54-year-old female admitted for syncope, who was on no medications except for insulin. Her electrocardiogram on admission had prolonged q-tc interval (0.50 ms.). She had repeated episodes of torsades de pointes during her hospitalization, which were later controlled by beta-blockers. Electrocardiograms of her mother and daughter showed asymptomatic prolonged q-tc interval. This syndrome has an autosomal dominant pattern of transmission and it was first described by Romano and Ward in a patient with normal hearing. Our case is unusual because this condition presented so late in life.
Collapse
Affiliation(s)
- W E Noble
- Department of Medicine, Robert C. Byrd Health Sciences Center of WVU, Morgantown
| | | | | |
Collapse
|