1
|
Pot GJ, Van Overschelde PA, Keulemans F, Kleverlaan CJ, Tribst JPM. Mechanical Properties of Additive-Manufactured Composite-Based Resins for Permanent Indirect Restorations: A Scoping Review. MATERIALS (BASEL, SWITZERLAND) 2024; 17:3951. [PMID: 39203129 PMCID: PMC11355578 DOI: 10.3390/ma17163951] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/02/2024] [Revised: 08/05/2024] [Accepted: 08/06/2024] [Indexed: 09/03/2024]
Abstract
The introduction of 3D printing technology in dentistry has opened new treatment options. The ongoing development of different materials for these printing purposes has recently enabled the production of definitive indirect restorations via 3D printing. To identify relevant data, a systematic search was conducted in three databases, namely PubMed, Scopus, and Web of Science. Additionally, a manual search using individual search terms was performed. Only English, peer-reviewed articles that encompassed in vitro or in vivo research on the mechanical properties of 3D-printed composite materials were included, provided they met the predefined inclusion and exclusion criteria. After screening 1142 research articles, 14 primary studies were selected. The included studies mainly utilized digital light processing (DLP) technology, less commonly stereolithography (SLA), and once PolyJet printing technology. The material properties of various composite resins, such as VarseoSmile Crown Plus (VSC) and Crowntec (CT), were studied, including Vickers hardness, flexural strength, elastic modulus, compressive strength, tensile strength, fracture resistance, and wear. The studies aimed to compare the behavior of the tested additive composites to each other, conventional composites, and subtractive-manufactured materials. This scoping review examined the mechanical properties of composites used for 3D printing of definitive restorations. The aim was to provide a comprehensive overview of the current knowledge on this topic and identify any gaps for future research. The findings suggest that 3D-printed composites are not yet the first option for indirect restorations, due to their insufficient mechanical properties. Due to limited evidence, more research is needed in this area. Specifically, there is a need for clinical trials and long-term in vivo research.
Collapse
Affiliation(s)
- Giny Judith Pot
- Department of Reconstructive Oral Care, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, 1081 LA Amsterdam, The Netherlands; (G.J.P.); (P.A.V.O.); (F.K.)
| | - Patricia Anna Van Overschelde
- Department of Reconstructive Oral Care, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, 1081 LA Amsterdam, The Netherlands; (G.J.P.); (P.A.V.O.); (F.K.)
| | - Filip Keulemans
- Department of Reconstructive Oral Care, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, 1081 LA Amsterdam, The Netherlands; (G.J.P.); (P.A.V.O.); (F.K.)
| | - Cornelis Johannes Kleverlaan
- Department of Dental Materials, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, 1081 LA Amsterdam, The Netherlands;
| | - João Paulo Mendes Tribst
- Department of Reconstructive Oral Care, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, 1081 LA Amsterdam, The Netherlands; (G.J.P.); (P.A.V.O.); (F.K.)
| |
Collapse
|
2
|
Klotz AL, Halfmann J, Rues S, Bömicke W, Rammelsberg P, Zenthöfer A. Fracture Resistance of Posterior Tooth-Supported Cantilever Fixed Dental Prostheses of Different Zirconia Generations and Framework Thicknesses: An In Vitro Study. MATERIALS (BASEL, SWITZERLAND) 2024; 17:263. [PMID: 38204115 PMCID: PMC10779861 DOI: 10.3390/ma17010263] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Revised: 12/20/2023] [Accepted: 12/21/2023] [Indexed: 01/12/2024]
Abstract
The rehabilitation of free-end situations is a frequent indication in prosthetic dentistry. Cantilever fixed dental prostheses (cFDPs) made of 1st and 2nd generation zirconia are one treatment option. Due to a unique gradient technology, combinations of different zirconium dioxide generations are thus feasible in one restoration. However, data about these materials are rare. The purpose of this study was therefore to investigate the fracture resistance and fracture modes of tooth-supported cFDPs fabricated from different zirconia materials (gradient technology) and different framework thicknesses. A total of 40 cFDPs were fabricated using the CAD/CAM approach and belonged to five test groups. The different groups differed in the yttria content, the proportion of the tetragonal/cubic phases, or in wall thickness (0.7 mm or 1 mm). After completion, the cFDPs were subjected to thermal cycling and chewing simulation (1.2 × 106 load cycles, 108 N load). Afterwards, cFDPs were statically loaded until fracture in a universal testing machine. A non-parametric ANOVA was compiled to determine the possible effects of group membership on fracture resistance. In addition, post-hoc Tukey tests were used for bivariate comparisons. The mean fracture loads under axial load application ranged from 288 to 577 N. ANOVA detected a significant impact of the used material on the fracture resistances (p < 0.001). Therefore, the use of cFDPs fabricated by gradient technology zirconia may not be unreservedly recommended for clinical use, whereas cFPDs made from 3Y-TZP exhibit fracture resistance above possible masticatory loads in the posterior region.
Collapse
Affiliation(s)
- Anna-Luisa Klotz
- Department of Prosthodontics, Dental School, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; (J.H.); (S.R.); (W.B.); (P.R.); (A.Z.)
| | | | | | | | | | | |
Collapse
|
3
|
Mayinger F, Meinen J, Coldea A, Zimmermann M, Stawarczyk B. Digital versus conventional veneering of zirconia and cobalt chromium crowns: Fracture load before and after thermomechanical aging. J Prosthet Dent 2023; 130:251.e1-251.e8. [PMID: 37244796 DOI: 10.1016/j.prosdent.2023.04.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Revised: 04/28/2023] [Accepted: 04/28/2023] [Indexed: 05/29/2023]
Abstract
STATEMENT OF PROBLEM To complement the digital workflow for manufacturing fixed dental prostheses, both high-strength frameworks and esthetic veneers should be designed and fabricated digitally. However, how the fracture load of digitally veneered restorations compares with conventionally fabricated restorations is unclear. PURPOSE The purpose of this in vitro study was to examine the fracture load of digitally and conventionally veneered zirconia and cobalt chromium crowns initially and after thermomechanical aging. MATERIAL AND METHODS Milled zirconia and cobalt chromium copings for a maxillary canine were fabricated (N=96). Digital veneers were milled and connected to the copings with a sintered ceramic slurry. The conventional veneers were fabricated by using a master mold, and the crowns were bonded to the cobalt chromium abutments. Half the specimens were subjected to 6000 thermal (5 °C to 55 °C, 60 seconds) and 1 200 000 mechanical (50 N, 1.5 Hz, 0.7 mm lateral movement) cycles opposed by steatite antagonists, and the fracture load was determined. Fracture types were categorized, and scanning electron microscopy performed. The data were analyzed with a 3-way global univariate analysis of variance, t test, the Pearson chi-squared test, and the Weibull modulus (α=.05). RESULTS Unlike the framework material (P=.316) and artificial aging (P=.064), the veneering protocol affected the fracture load (P=.007). Digital veneers (range: 2242 to 2929 N) led to lower values than conventional veneers (range: 2825 to 3166 N), which was significant for aged cobalt chromium copings (P=.024; 2242 versus 3107 N). Conventionally veneered crowns showed lower Weibull moduli after thermomechanical aging (range: 3.2 to 3.5) than initially (range: 7.8 to 11.4). The copings of all the zirconia specimens fractured, while chipping occurred with the cobalt chromium specimens. CONCLUSIONS The high fracture load values of the veneered crowns, even after simulated 5-year aging, indicated sufficient mechanical properties (nearly 4-fold the average occlusal force of 600 N) for the successful clinical application of digitally veneered zirconia and cobalt chromium copings.
Collapse
Affiliation(s)
- Felicitas Mayinger
- Research Associate, Department of Prosthetic Dentistry, Dental School, Ludwig Maximilian University of Munich, Munich, Germany.
| | - John Meinen
- Dental Technician, Department of Prosthetic Dentistry, Dental School, Ludwig Maximilian University of Munich, Munich, Germany
| | - Andrea Coldea
- Research Associate, Department of Prosthetic Dentistry, Dental School, Ludwig Maximilian University of Munich, Munich, Germany
| | - Marcus Zimmermann
- Dental Technician, Division of Computerized Restorative Dentistry, Clinic of Conservative and Preventive Dentistry, Center of Dental Medicine, University of Zürich, Zürich, Switzerland
| | - Bogna Stawarczyk
- Professor, Department of Prosthetic Dentistry, Dental School, Ludwig Maximilian University of Munich, Munich, Germany
| |
Collapse
|
4
|
Fracture Load and Fracture Patterns of Monolithic Three-Unit Anterior Fixed Dental Prostheses after In Vitro Artificial Aging-A Comparison between Color-Gradient and Strength-Gradient Multilayer Zirconia Materials with Varying Yttria Content. J Clin Med 2022; 11:jcm11174982. [PMID: 36078912 PMCID: PMC9457031 DOI: 10.3390/jcm11174982] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Revised: 08/18/2022] [Accepted: 08/19/2022] [Indexed: 12/02/2022] Open
Abstract
(1) Background: Due to advantages such as avoidance of chipping, pulp-friendly tooth preparation and cost reduction, zirconia is increasingly being used monolithically without veneering. Nevertheless, to enable good aesthetics, various multilayer systems have been developed. The aim of this study was to investigate the impact of different zirconia multilayer strategies and yttria levels on fracture load, fracture pattern, stress distribution and surface roughness. (2) Methods: Monolithic three-unit anterior FDPs were made from three different color-gradient zirconia multilayer materials with different yttria levels corresponding to varying strength and degrees of translucency grades (Katana HTML, STML, UTML, Kuraray) and one strength-gradient zirconia multilayer material (Katana YML, Kuraray) and artificially aged in a chewing simulator (1.2 × 106 load cycles, 50 N, 2 × 3000 thermocycles, 5−55 °C). Analyses of fracture load, fracture pattern, fracture surfaces, stress distribution and roughness were performed after the fracture load test. Shapiro−Wilk, Kruskal−Wallis, Mann−Whitney U-tests and one-way ANOVA were used (p < 0.05). (3) Results: Fracture loads of the high strength color-gradient material HTML and the strength-gradient material YML were comparable after 5 years of aging (p = 0.645). Increasing yttria levels resulted in a decrease in fracture resistance of 42−57% (p < 0.05). Surface roughness of different zirconia generations is comparable after polishing and aging. (4) Conclusions: Color-gradient multilayer zirconia materials and new strength-gradient zirconia materials with similar yttria levels in the basal layers show comparable mechanical properties and are suitable for anterior FDPs.
Collapse
|
5
|
Sass JO, Burmeister U, Ganz C, Mitrovic A, Lang H, Bader R, Vogel D. Fracture strength of monolithic and glass-soldered ceramic sub-components of 5-unit fixed dental prosthesis. J Prosthodont 2022; 32:e71-e80. [PMID: 35924927 DOI: 10.1111/jopr.13586] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2022] [Accepted: 07/27/2022] [Indexed: 11/30/2022] Open
Abstract
PURPOSE Zirconium dioxide ceramic has been successfully introduced as a framework material for fixed dental prostheses. To reduce manufacturing constraints, joining of sub-components could be a promising approach to increase the mechanical performance of long-span fixed dental prostheses. In this experimental study, the biomechanical behavior of monolithic and soldered framework specimens for fixed dental prostheses made of Y-TZP was investigated. MATERIALS AND METHODS Framework specimens (n = 80) of 5-unit fixed dental prostheses made of Y-TZP were prepared and divided into 10 equal groups. The specimens were monolithic or composed of sub-components, which were joined using a silicate-based glass solder. Thereby, three joint geometries (diagonal, vertical with an occlusal cap, and dental attachment-based) were investigated. Moreover, the groups differed based on the mechanical test (static vs. dynamic) and further processing (veneered vs. unveneered). The framework specimens were cemented on alumina-based jaw models, where the canine and second molar were acting as abutments, before a point-load was applied. In addition, μCT scans and microscopic fractography was used to evaluate the quality of soldered joints and to determine the causes of fracture. RESULTS The determined fracture loads of the different unveneered framework specimens in static testing did not vary significantly (p = 1). Adding a veneering layer significantly increased the mechanical strength for monolithic framework specimens from 1,196.29 ±203.79 N to 1,606.85 ±128.49 N (p = 0.008). In case of soldered specimens with a dental attachment-based geometry the mechanical strength increased from 1,159.42 ±85.65 N to 1,249.53 ±191.55 N (p = 1). Within the dynamic testing, no differences were observed between monolithic and soldered framework specimens. μCT scans and fractography proved that the dental attachment-based joining geometry offers the highest quality. CONCLUSION Using glass soldering technology, sub-components of 5-unit framework specimens made of Y-TZP could be joined with mechanical properties comparable to those of monolithic frameworks. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Jan-Oliver Sass
- Department of Orthopedics, Rostock University Medical Center, Rostock, Germany.,Department of Operative Dentistry and Periodontology, Rostock University Medical Center, Rostock, Germany
| | - Ulrike Burmeister
- Department of Operative Dentistry and Periodontology, Rostock University Medical Center, Rostock, Germany
| | | | | | - Hermann Lang
- Department of Operative Dentistry and Periodontology, Rostock University Medical Center, Rostock, Germany
| | - Rainer Bader
- Department of Orthopedics, Rostock University Medical Center, Rostock, Germany
| | - Danny Vogel
- Department of Orthopedics, Rostock University Medical Center, Rostock, Germany
| |
Collapse
|
6
|
Demirci F, Bahce E, Baran MC. Mechanical analysis of three-unit metal-free fixed dental prostheses produced in different materials with CAD/CAM technology. Clin Oral Investig 2022; 26:5969-5978. [DOI: 10.1007/s00784-022-04623-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Accepted: 07/11/2022] [Indexed: 11/03/2022]
|
7
|
Mayinger F, Buser R, Laier M, Schönhoff LM, Kelch M, Hampe R, Stawarczyk B. Impact of the material and sintering protocol, layer thickness, and thermomechanical aging on the two-body wear and fracture load of 4Y-TZP crowns. Clin Oral Investig 2022; 26:6617-6628. [PMID: 35840737 DOI: 10.1007/s00784-022-04616-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2022] [Accepted: 07/04/2022] [Indexed: 11/03/2022]
Abstract
OBJECTIVES The aim of this study is to investigate the influence of the material and corresponding sintering protocol, layer thickness, and aging on the two-body wear (2BW) and fracture load (FL) of 4Y-TZP crowns. MATERIALS AND METHODS Multi-layer 4Y-TZP crowns in three thicknesses (0.5 mm/1.0 mm/1.5 mm) were sintered by high-speed (Zolid RS) or conventional (Zolid Gen-X) sintering. 2BW of ceramic and enamel antagonist after aging (1,200,000 mechanical-, 6000 thermal-cycles) was determined by 3D-scanning before and after aging and subsequent matching to determine volume and height loss (6 subgroups, n = 16/subgroup). FL was examined initially and after aging (12 subgroups, n = 16/subgroup). Fractographic analyses were performed using light-microscope imaging. Global univariate analysis of variance, one-way ANOVA, linear regression, Spearman's correlation, Kolgomorov-Smirnov, Mann-Whitney U, and t test were computed (alpha = 0.05). Weibull moduli were determined. Fracture types were analyzed using Ciba Geigy table. RESULTS Material/sintering protocol did not influence 2BW (crowns: p = 0.908, antagonists: p = 0.059). High-speed sintered Zolid RS presented similar (p = 0.325-0.633) or reduced (p < 0.001-0.047) FL as Zolid Gen-X. Both 4Y-TZPs showed an increased FL with an increasing thickness (0.5(797.3-1429 N) < 1.0(2087-2634 N) < 1.5(2683-3715 N)mm; p < 0.001). For most groups, aging negatively impacted FL (p < 0.001-0.002). Five 0.5 mm specimens fractured, four showed cracks during and after aging. CONCLUSIONS High-speed sintered crowns with a minimum thickness of 1.0 mm showed sufficient mechanical properties to withstand masticatory forces, even after a simulated aging period of 5 years. CLINICAL RELEVANCE Despite the manufacturer indicating a thickness of 0.5 mm to be suitable for single crowns, a minimum thickness of 1.0 mm should be used to ensure long-term satisfactory results.
Collapse
Affiliation(s)
- Felicitas Mayinger
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany.
| | - Ramona Buser
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany.,Department of Reconstructive Dentistry and Gerodontology, University of Bern, Freiburgstrasse 7, 3007, Bern, Switzerland
| | - Maximilian Laier
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| | - Lisa Marie Schönhoff
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| | - Matthias Kelch
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| | - Rüdiger Hampe
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| | - Bogna Stawarczyk
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| |
Collapse
|
8
|
Schmeiser F, Arbogast F, Ruppel H, Mayinger F, Reymus M, Stawarczyk B. Methodology investigation: Impact of crown geometry, crown, abutment and antagonist material and thermal loading on the two-body wear of dental materials. Dent Mater 2021; 38:266-280. [PMID: 34953628 DOI: 10.1016/j.dental.2021.12.009] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Revised: 11/19/2021] [Accepted: 12/08/2021] [Indexed: 11/03/2022]
Abstract
OBJECTIVES To investigate the impact of crown geometry, crown/abutment/antagonist material and thermal loading on the two-body wear of dental materials caused by chewing simulation. MATERIALS AND METHODS For the crown geometry, crowns (polymethylmethacrylate (PMMA), polyetheretherketone (PEEK) and silicate ceramic (SiO2)) were milled with a flat, steep, or medium cusp inclination (CINC). For the crown/abutment material, crowns (PMMA, PEEK and SiO2) were combined with PMMA, polymer-infiltrated-ceramic-network (PICN), cobalt-chrome alloy (CoCr) and natural teeth (ENAM) abutments. For the antagonist material, antagonists were fabricated from PICN, CAD/CAM resin composite (RECO), steatite (STEA), steel (STL) and ENAM and tested against flat specimens (substrates) made of veneering ceramic (VC). For thermal loading, the duration (30 s, 60 s, 120 s) and presence of temperature changes (37 °C versus 5 °C/55 °C) was varied. Material losses were determined by matching scanned specimens before and after aging (400,000 chewing cycles, 50 N, 1.3 Hz). Martens parameters were determined for the antagonists/substrates. Data were analyzed using Kolmogorov-Smirnov-test, Kruskal-Wallis H, Scheffé-Post-Hoc-tests, pairwise comparisons, Bonferroni correction, one-way ANOVA, Mann-Whitney-U and Spearman rho. RESULTS PMMA crowns presented the highest and PEEK the lowest material losses. Flat CINC showed the lowest material losses for PEEK and SiO2 crowns. CoCr and ENAM abutments presented material losses in the same range. Antagonist and cumulative material losses for RECO and ENAM were similar. Thermal loading did not influence material losses. SIGNIFICANCE Crown geometry influences the crown and antagonists wear, with an increased cusp inclination entailing increased wear. For in vitro set-ups, CoCr abutments and RECO antagonists present valid alternatives to natural teeth. For polymers, in vitro chewing simulations may be performed at a constant temperature (37 °C).
Collapse
Affiliation(s)
- Felix Schmeiser
- Dental Material Unit, Department of Prosthetic Dentistry, University Hospital Ludwig-Maximilians-University, Goethestrasse 70, 80336 Munich, Germany.
| | - Fee Arbogast
- Dental Material Unit, Department of Prosthetic Dentistry, University Hospital Ludwig-Maximilians-University, Goethestrasse 70, 80336 Munich, Germany
| | - Hendrik Ruppel
- Dental Material Unit, Department of Prosthetic Dentistry, University Hospital Ludwig-Maximilians-University, Goethestrasse 70, 80336 Munich, Germany
| | - Felicitas Mayinger
- Dental Material Unit, Department of Prosthetic Dentistry, University Hospital Ludwig-Maximilians-University, Goethestrasse 70, 80336 Munich, Germany
| | - Marcel Reymus
- Department of Conservative Dentistry and Periodontology, University Hospital Ludwig-Maximilians-University, Goethestrasse 70, 80336 Munich, Germany
| | - Bogna Stawarczyk
- Dental Material Unit, Department of Prosthetic Dentistry, University Hospital Ludwig-Maximilians-University, Goethestrasse 70, 80336 Munich, Germany
| |
Collapse
|
9
|
Tobar C, Rodriguez V, Lopez-Suarez C, Pelaez J, Suarez MJ. Influence of Digital Technologies and Framework Design on the Load to Fracture of Co-Cr Posterior Fixed Partial Denture Frameworks. J Prosthodont 2021; 31:606-613. [PMID: 34860426 DOI: 10.1111/jopr.13458] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/25/2021] [Indexed: 12/01/2022] Open
Abstract
PURPOSE To compare the load to fracture of cobalt-chromium (Co-Cr) 3-unit posterior fixed partial denture (FPD) frameworks manufactured by conventional and digital techniques and to evaluate the influence of the framework design on the fracture load. MATERIAL AND METHODS Eighty 3-unit Co-Cr posterior FPD frameworks were fabricated with two designs: intermediate pontic (n = 40) and cantilever (n = 40). Each design was randomly divided into four groups (n = 10): casting, direct metal laser sintering, soft metal milling, and hard metal milling. After thermal cycling, all specimens were subjected to a 3-point bending test until fracture. Data were statistically analyzed using one-way ANOVA, Welch and Brown-Forsythe test, Ryan-Einot-Gabriel-Welsch F and Tamhane T2 post hoc test, Student's t test, and Weibull statistics (α = 0.05). RESULTS Significant differences (p < 0.001; F = 39.59) were found among intermediate pontic frameworks (except between laser sintering and hard metal milling), and cantilevered frameworks (F = 36.75) (except between laser sintering and hard metal milling, and casting and soft metal milling). The cantilever groups showed load to fracture values significantly lower than those of the intermediate pontic (p < 0.001; F = 28.29). The Weibull statistics corroborated the results. CONCLUSIONS Hard metal milling and laser sintered frameworks exhibited the highest load to fracture values. However, all tested frameworks demonstrated clinically acceptable load to fracture values. The framework design directly affected the fracture load, with drastically lower values in cantilevered frameworks.
Collapse
Affiliation(s)
- Celia Tobar
- Department of Conservative Dentistry and Buccofacial Prostheses, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain
| | - Veronica Rodriguez
- Department of Conservative Dentistry and Buccofacial Prostheses, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain
| | - Carlos Lopez-Suarez
- Department of Conservative Dentistry and Buccofacial Prostheses, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain
| | - Jesus Pelaez
- Department of Conservative Dentistry and Buccofacial Prostheses, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain
| | - Maria J Suarez
- Department of Conservative Dentistry and Buccofacial Prostheses, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain
| |
Collapse
|
10
|
Wiedenmann F, Pfefferle R, Reichert A, Jerman E, Stawarczyk B. Impact of high-speed sintering, layer thickness and artificial aging on the fracture load and two-body wear of zirconia crowns. Dent Mater 2020; 36:846-853. [PMID: 32414506 DOI: 10.1016/j.dental.2020.04.004] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2019] [Revised: 03/18/2020] [Accepted: 04/13/2020] [Indexed: 10/24/2022]
Abstract
OBJECTIVE To investigate the impact of high-speed sintering, layer thickness and artificial aging in a chewing simulator on the fracture load (FL) and two-body wear (2BW) of 4Y-TZP crowns. METHODS 4Y-TZP crowns (Ceramill Zolid HT+, Amann Girrbach AG) in three different layer thicknesses (0.5, 1.0, 1.5; N=192, n=64/group) were manufactured using CAD/CAM technology and sintered at 1580°C (high-speed sintering) or 1450°C (control group). Specimens were polished in two-steps and bonded to standardized CoCr abutments with Multilink Automix (Ivoclar Vivadent). 2BW after 6000 thermo- and 1,200,000 chewing-cycles employing enamel antagonists was determined using best fit machining. FL was tested before and after artificial aging. Univariate ANOVAs, post hoc Scheffé, unpaired t-, Kruskal-Wallis- and Mann-Whitney-U-test were computed (p<0.05). RESULTS High-speed sintering resulted in less 2BW of the zirconia than the control group (p=0.013). High-speed sintering (p=0.001-0.006) and an increase in layer thickness (p<0.001-0.012) resulted in higher FL values, while artificial aging led to a reduction of FL (p<0.001). SIGNIFICANCE As high-speed sintering resulted in less two-body wear of the zirconia and comparable or even higher fracture load results than the control group, this cost- and time efficient alternative presents promising mechanical results.
Collapse
Affiliation(s)
- Felicitas Wiedenmann
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestraße 70, 80336 Munich, Germany.
| | - Regina Pfefferle
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestraße 70, 80336 Munich, Germany
| | - Axel Reichert
- Research & Development, Amann Girrbach GmbH, Herrschaftswiesen 1, 6842 Koblach, Austria
| | - Eva Jerman
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestraße 70, 80336 Munich, Germany
| | - Bogna Stawarczyk
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestraße 70, 80336 Munich, Germany
| |
Collapse
|
11
|
Kist S, Stawarczyk B, Kollmuss M, Hickel R, Huth KC. Fracture load and chewing simulation of zirconia and stainless‐steel crowns for primary molars. Eur J Oral Sci 2019; 127:369-375. [DOI: 10.1111/eos.12645] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/28/2019] [Indexed: 11/28/2022]
Affiliation(s)
- Stefan Kist
- Department of Conservative Dentistry and Periodontology University HospitalLMU Munich MunichGermany
| | - Bogna Stawarczyk
- Department of Prosthetic Dentistry University Hospital LMU Munich Munich Germany
| | - Maximilian Kollmuss
- Department of Conservative Dentistry and Periodontology University HospitalLMU Munich MunichGermany
| | - Reinhard Hickel
- Department of Conservative Dentistry and Periodontology University HospitalLMU Munich MunichGermany
| | - Karin C. Huth
- Department of Conservative Dentistry and Periodontology University HospitalLMU Munich MunichGermany
| |
Collapse
|
12
|
Zimmermann M, Ender A, Attin T, Mehl A. Fracture load of three-unit full-contour fixed dental prostheses fabricated with subtractive and additive CAD/CAM technology. Clin Oral Investig 2019; 24:1035-1042. [DOI: 10.1007/s00784-019-03000-0] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2019] [Accepted: 06/28/2019] [Indexed: 10/26/2022]
|
13
|
Waldecker M, Rues S, Rammelsberg P, Bömicke W. Validation of in-vitro tests of zirconia-ceramic inlay-retained fixed partial dentures: A finite element analysis. Dent Mater 2019; 35:e53-e62. [PMID: 30686709 DOI: 10.1016/j.dental.2019.01.017] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2018] [Revised: 12/13/2018] [Accepted: 01/13/2019] [Indexed: 10/27/2022]
Abstract
OBJECTIVE In the past, discrepancies between laboratory results and clinical behavior have been observed for all-ceramic restorations. This analysis of fracture resistance of zirconia-based inlay-retained fixed partial dentures (IRFPDs) aimed at identifying correlations between an in-vitro test setup and the clinical situation. The effects of tooth material, tooth mobility, restoration design, load direction, and different cements were taken into account. METHODS The in-vitro test model and IRFPD were reverse engineered (Geomagic DesignX) and meshed predominantly with hexahedral elements (approx. 230,000 elements). Homogenous, linear-elastic behavior was assumed for all materials. On the basis of the calculated stresses (ANSYS 18.2) and already known strength distributions for the restorative materials fracture resistance of the complete restoration and force at initial damage (fracture within the veneer) was estimated on the basis of the principal stress hypothesis. Differences depending on the assumed clinical situation and effects of different variables on fracture resistance were evaluated. RESULTS All variables tested in the finite element analysis affected the calculated fracture resistance of the IRFPD. Use of resin teeth led to an underestimation of fracture resistance by up to -57%, whereas fracture resistance of IRFPDs on metal abutment teeth was close to the clinical reference (-6% to +15%). Good correlation between the clinical scenario and that using metal teeth could only be achieved when the natural resilience of the abutment teeth was simulated. SIGNIFICANCE When testing fracture resistance of zirconia-based IRFPDs, metal abutment teeth in combination with simulated tooth resilience can reflect the clinical situation accurately.
Collapse
Affiliation(s)
- M Waldecker
- Department of Prosthodontics, Heidelberg University Hospital, University of Heidelberg, Heidelberg, Germany.
| | - S Rues
- Department of Prosthodontics, Heidelberg University Hospital, University of Heidelberg, Heidelberg, Germany
| | - P Rammelsberg
- Department of Prosthodontics, Heidelberg University Hospital, University of Heidelberg, Heidelberg, Germany
| | - W Bömicke
- Department of Prosthodontics, Heidelberg University Hospital, University of Heidelberg, Heidelberg, Germany
| |
Collapse
|
14
|
Stimmelmayr M, Groesser J, Beuer F, Erdelt K, Krennmair G, Sachs C, Edelhoff D, Güth JF. Accuracy and mechanical performance of passivated and conventional fabricated 3-unit fixed dental prosthesis on multi-unit abutments. J Prosthodont Res 2017; 61:403-411. [DOI: 10.1016/j.jpor.2016.12.011] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2016] [Revised: 10/12/2016] [Accepted: 12/28/2016] [Indexed: 11/30/2022]
|
15
|
Choi JW, Kim SY, Bae JH, Bae EB, Huh JB. In vitro study of the fracture resistance of monolithic lithium disilicate, monolithic zirconia, and lithium disilicate pressed on zirconia for three-unit fixed dental prostheses. J Adv Prosthodont 2017; 9:244-251. [PMID: 28874990 PMCID: PMC5582089 DOI: 10.4047/jap.2017.9.4.244] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2016] [Revised: 02/17/2017] [Accepted: 03/15/2017] [Indexed: 11/25/2022] Open
Abstract
PURPOSE The purpose of this study was to determine fracture resistance and failure modes of three-unit fixed dental prostheses (FDPs) made of lithium disilicate pressed on zirconia (LZ), monolithic lithium disilicate (ML), and monolithic zirconia (MZ). MATERIALS AND METHODS Co-Cr alloy three-unit metal FDPs model with maxillary first premolar and first molar abutments was fabricated. Three different FDPs groups, LZ, ML, and MZ, were prepared (n = 5 per group). The three-unit FDPs designs were identical for all specimens and cemented with resin cement on the prepared metal model. The region of pontic in FDPs was given 50,000 times of cyclic preloading at 2 Hz via dental chewing simulator and received a static load until fracture with universal testing machine fixed at 10°. The fracture resistance and mode of failure were recorded. Statistical analyses were performed using the Kruskal-Wallis test and Mann-Whitney U test with Bonferroni's correction (α=0.05/3=0.017). RESULTS A significant difference in fracture resistance was found between LZ (4943.87 ± 1243.70 N) and ML (2872.61 ± 658.78 N) groups, as well as between ML and MZ (4948.02 ± 974.51 N) groups (P<.05), but no significant difference was found between LZ and MZ groups (P>.05). With regard to fracture pattern, there were three cases of veneer chipping and two interfacial fractures in LZ group, and complete fracture was observed in all the specimens of ML and MZ groups. CONCLUSION Compared to monolithic lithium disilicate FDPs, monolithic zirconia FDPs and lithium disilicate glass ceramics pressed on zirconia-based FDPs showed superior fracture resistance while they manifested comparable fracture resistances.
Collapse
Affiliation(s)
- Jae-Won Choi
- Department of Prosthodontics, Dental Research Institute, Institute of Translation Dental Science, School of Dentistry, Pusan National University, Yangsan, Republic of Korea.,BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - So-Yeun Kim
- Department of Prosthodontics, Pusan National University Hospital, Pusan, Republic of Korea
| | - Ji-Hyeon Bae
- Department of Prosthodontics, Dental Research Institute, Institute of Translation Dental Science, School of Dentistry, Pusan National University, Yangsan, Republic of Korea.,BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Eun-Bin Bae
- Department of Prosthodontics, Dental Research Institute, Institute of Translation Dental Science, School of Dentistry, Pusan National University, Yangsan, Republic of Korea.,BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Jung-Bo Huh
- Department of Prosthodontics, Dental Research Institute, Institute of Translation Dental Science, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| |
Collapse
|
16
|
Bömicke W, Rues S, Hlavacek V, Rammelsberg P, Schmitter M. Fracture Behavior of Minimally Invasive, Posterior, and Fixed Dental Prostheses Manufactured from Monolithic Zirconia. J ESTHET RESTOR DENT 2016; 28:367-381. [DOI: 10.1111/jerd.12242] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Wolfgang Bömicke
- Doctor of Medical Dentistry, Department of Prosthodontics; Heidelberg University Hospital, University of Heidelberg; Germany
| | - Stefan Rues
- Engineer Diploma, Department of Prosthodontics; Heidelberg University Hospital, University of Heidelberg; Germany
| | - Verena Hlavacek
- Doctor of Medical Dentistry, Department of Prosthodontics; Heidelberg University Hospital, University of Heidelberg; Germany
| | - Peter Rammelsberg
- Professor Doctor of Medical Dentistry, Department of Prosthodontics; Heidelberg University Hospital, University of Heidelberg; Germany
| | - Marc Schmitter
- Professor Doctor of Medical Dentistry, Department of Prosthodontics; Heidelberg University Hospital, University of Heidelberg; Germany
| |
Collapse
|
17
|
Torabi K, Vojdani M, Giti R, Taghva M, Pardis S. The effect of various veneering techniques on the marginal fit of zirconia copings. J Adv Prosthodont 2015; 7:233-9. [PMID: 26140175 PMCID: PMC4486619 DOI: 10.4047/jap.2015.7.3.233] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2014] [Revised: 03/16/2015] [Accepted: 04/13/2015] [Indexed: 11/08/2022] Open
Abstract
PURPOSE This study aimed to evaluate the fit of zirconia ceramics before and after veneering, using 3 different veneering processes (layering, press-over, and CAD-on techniques). MATERIALS AND METHODS Thirty standardized zirconia CAD/CAM frameworks were constructed and divided into three groups of 10 each. The first group was veneered using the traditional layering technique. Press-over and CAD-on techniques were used to veneer second and third groups. The marginal gap of specimens was measured before and after veneering process at 18 sites on the master die using a digital microscope. Paired t-test was used to evaluate mean marginal gap changes. One-way ANOVA and post hoc tests were also employed for comparison among 3 groups (α=.05). RESULTS Marginal gap of 3 groups was increased after porcelain veneering. The mean marginal gap values after veneering in the layering group (63.06 µm) was higher than press-over (50.64 µm) and CAD-on (51.50 µm) veneered groups (P<.001). CONCLUSION Three veneering methods altered the marginal fit of zirconia copings. Conventional layering technique increased the marginal gap of zirconia framework more than pressing and CAD-on techniques. All ceramic crowns made through three different veneering methods revealed clinically acceptable marginal fit.
Collapse
Affiliation(s)
- Kianoosh Torabi
- Department of Prosthodontics, Faculty of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Mahroo Vojdani
- Biomaterial Research Center, Department of Prosthodontics, Faculty of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Rashin Giti
- Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Masumeh Taghva
- Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Soheil Pardis
- Department of Oral and Maxillofacial Pathology, Faculty of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| |
Collapse
|