1
|
Yu N, Dai HW, Tan FB, Song JL, Ma CY, Tong XL. Effect of different tooth preparation designs on the marginal and internal fit discrepancies of cobalt-chromium crowns produced by computer-aided designing and selective laser melting processes. J Adv Prosthodont 2021; 13:333-342. [PMID: 34777722 PMCID: PMC8558576 DOI: 10.4047/jap.2021.13.5.333] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2021] [Revised: 09/10/2021] [Accepted: 10/18/2021] [Indexed: 11/08/2022] Open
Abstract
PURPOSE To evaluate the impact of five different tooth preparation designs on the marginal and internal fit discrepancies of cobalt-chromium (CoCr) crowns produced by computer-aided designing (CAD) and selective laser melting (SLM) processes. MATERIALS AND METHODS Five preparation data were constructed, after which design crowns were obtained. Actual crowns were fabricated using an SLM process. After the data of actual crowns were obtained with structural light scanning, intaglio surfaces of the design crown and actual crown were virtually superimposed on the preparation. The fit-discrepancies were displayed with colors, while the root means square was calculated and analyzed with one-way analysis of variance (ANOVA), Tukey's test or Kruskal-Wallis test (α =.05). RESULTS The marginal or internal color-coded images in the five design groups were not identical. The shoulder-lip and sharp line angle groups in the CAD or SLM process had larger marginal or internal fit discrepancies compared to other groups (P < .05). In the CAD process, the mean marginal and internal fit discrepancies were 10.0 to 24.2 µm and 29.6 to 31.4 µm, respectively. After the CAD and SLM processes, the mean marginal and internal fit discrepancies were 18.4 to 40.9 µm and 39.1 to 47.1 µm, respectively. The SLM process itself resulted in a positive increase of the marginal (6.0 - 16.7 µm) and internal (9.0 - 15.7 µm) fit discrepancies. CONCLUSION The CAD and SLM processes affected the fit of CoCr crowns and varied based on the preparation designs. Typically, the shoulder-lip and sharp line angle designs had a more significant effect on crown fit. However, the differences between the design groups were relatively small, especially when compared to fit discrepancies observed clinically.
Collapse
Affiliation(s)
- Na Yu
- College of Stomatology, Chongqing Medical University, Chongqing, China.,Chongqing Key Laboratory for Oral Diseases and Biomedical Sciences, Chongqing, China
| | - Hong-Wei Dai
- College of Stomatology, Chongqing Medical University, Chongqing, China.,Chongqing Key Laboratory for Oral Diseases and Biomedical Sciences, Chongqing, China
| | - Fa-Bing Tan
- College of Stomatology, Chongqing Medical University, Chongqing, China.,Chongqing Key Laboratory for Oral Diseases and Biomedical Sciences, Chongqing, China.,Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China
| | - Jin-Lin Song
- College of Stomatology, Chongqing Medical University, Chongqing, China.,Chongqing Key Laboratory for Oral Diseases and Biomedical Sciences, Chongqing, China.,Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China
| | - Chao-Yi Ma
- College of Stomatology, Chongqing Medical University, Chongqing, China.,Chongqing Key Laboratory for Oral Diseases and Biomedical Sciences, Chongqing, China
| | - Xue-Lu Tong
- College of Stomatology, Chongqing Medical University, Chongqing, China.,Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China
| |
Collapse
|
2
|
Habib SR. Digital microscopic evaluation of vertical marginal discrepancies of CAD/CAM fabricated zirconia cores. ACTA ACUST UNITED AC 2019; 64:207-214. [PMID: 29775437 DOI: 10.1515/bmt-2017-0234] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2017] [Accepted: 04/16/2018] [Indexed: 11/15/2022]
Abstract
OBJECTIVE The aim of this in vitro research study was to evaluate the vertical marginal discrepancies of zirconia (Zr) cores fabricated by five different computer-aided design and manufacturing (CAD/CAM) systems using a digital microscope. MATERIALS AND METHODS A total of 60 specimens were prepared and randomly divided into five groups (n=12 each) using the following systems: Ceramill Motion 2 (CM, Amanngirrbach, Germany); Weiland (WI, Ivoclar Vivadent, USA); Cerec (CS, Sirona Dental, USA); Zirkonzahn (ZZ, Gmbh Bruneck, Italy) and Cad4dent (CD, Canada). The specimens were numbered and the vertical marginal discrepancies were evaluated with a digital microscope at 50× magnification. RESULTS A one-way analysis of variance showed a statistically significant difference (p=0.002) between the groups. The CM group exhibited the lowest values for the marginal gaps (31.30±15.12 μm), while the ZZ group exhibited the highest values for the marginal gaps (44.83±28.76 μm) compared to other groups. A post hoc Tukey's test for multiple comparisons between the experimental groups showed a statistically significant difference (p<0.05) between the group CM and group CD with group ZZ. The rest of the groups showed no significant differences between them. Variations in the values were observed for the four sites measured with the highest and the least mean marginal gap value of 43.19±23.84 μm and 32.49±12.21 μm for buccal and lingual sites, respectively. CONCLUSION Variations existed in the marginal discrepancy values for the CAD/CAM systems investigated in the study. Vertical marginal discrepancy values observed for various systems investigated in the study were well within the clinically acceptable range.
Collapse
Affiliation(s)
- Syed Rashid Habib
- Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, P.O. Box 60169, King Abdullah Road, Riyadh, 11545, Saudi Arabia
| |
Collapse
|
3
|
Bohner L, Hanisch M, De Luca Canto G, Mukai E, Sesma N, Neto PT. Accuracy of Casts Fabricated by Digital and Conventional Implant Impressions. J ORAL IMPLANTOL 2019; 45:94-99. [DOI: 10.1563/aaid-joi-d-17-00142] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The purpose of this study was to compare the accuracy of stereolithographic casts (SCs) with those obtained using conventional implant impressions. An epoxy resin model containing dental implants was used as master model. Dental casts (n = 10) were fabricated through both conventional and digital implant impressions. The conventional casts (CCs), SCs, and the master model were digitized, and the accuracy was determined through a deviation analysis and linear measurements. Data were analyzed using paired Student t test with P < .05. The SCs showed higher deviation at the vestibular area (CC: 41 ± 28.87 μm; SC: 117 ± 36.83 μm) and lingual cusps (CC: 40.70 ± 19.79 μm; SC: 80 ± 42.95 μm) in comparison with CCs. No statistically significant difference was found for linear measurements of conventional and digital casts. The entire-arch accuracy was comparable between casts. However, SCs were less accurate at the cusp level in comparison with CCs.
Collapse
Affiliation(s)
- Lauren Bohner
- Department of Prosthodontics, School of Dentistry, University of São Paulo, São Paulo, Brazil
- Department of Oral and Maxillofacial Surgery, Hospital University Münster, Münster, Germany
| | - Marcel Hanisch
- Department of Oral and Maxillofacial Surgery, Hospital University Münster, Münster, Germany
| | - Graziela De Luca Canto
- Department of Dentistry, Federal University of Santa Catarina, Florianópolis, SC, Brazil
- Departmento of Dentistry, University of Alberta, Alberta, Canada
| | - Eduardo Mukai
- Department of Prosthodontics, School of Dentistry, University of São Paulo, São Paulo, Brazil
| | - Newton Sesma
- Department of Prosthodontics, School of Dentistry, University of São Paulo, São Paulo, Brazil
| | - Pedro Tortamano Neto
- Department of Prosthodontics, School of Dentistry, University of São Paulo, São Paulo, Brazil
| |
Collapse
|
4
|
Tan FB, Wang C, Dai HW, Fan YB, Song JL. Accuracy and reproducibility of 3D digital tooth preparations made by gypsum materials of various colors. J Adv Prosthodont 2018; 10:8-17. [PMID: 29503709 PMCID: PMC5829291 DOI: 10.4047/jap.2018.10.1.8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2017] [Revised: 07/29/2017] [Accepted: 08/29/2017] [Indexed: 11/08/2022] Open
Abstract
PURPOSE The study aimed to identify the accuracy and reproducibility of preparations made by gypsum materials of various colors using quantitative and semi-quantitative three-dimensional (3D) approach. MATERIALS AND METHODS A titanium maxillary first molar preparation was created as reference dataset (REF). Silicone impressions were duplicated from REF and randomized into 6 groups (n=8). Gypsum preparations were formed and grouped according to the color of gypsum materials, and light-scanned to obtain prepared datasets (PRE). Then, in terms of accuracy, PRE were superimposed on REF using the best-fit-algorithm and PRE underwent intragroup pairwise best-fit alignment for assessing reproducibility. Root mean square deviation (RMSD) and degrees of similarity (DS) were computed and analyzed with SPSS 20.0 statistical software (α=.05). RESULTS In terms of accuracy, PREs in 3D directions were increased in the 6 color groups (from 19.38 to 20.88 µm), of which the marginal and internal variations ranged 51.36 - 58.26 µm and 18.33 - 20.04 µm, respectively. On the other hand, RMSD value and DS-scores did not show significant differences among groups. Regarding reproducibility, both RMSD and DS-scores showed statistically significant differences among groups, while RMSD values of the 6 color groups were less than 5 µm, of which blue color group was the smallest (3.27 ± 0.24 µm) and white color group was the largest (4.24 ± 0.36 µm). These results were consistent with the DS data. CONCLUSION The 3D volume of the PREs was predisposed towards an increase during digitalization, which was unaffected by gypsum color. Furthermore, the reproducibility of digitalizing scanning differed negligibly among different gypsum colors, especially in comparison to clinically observed discrepancies.
Collapse
Affiliation(s)
- Fa-Bing Tan
- College of Stomatology, Chongqing Medical University, Chongqing, China.,Chongqing Key Laboratory for Oral Diseases and Biomedical Sciences, Chongqing, China
| | - Chao Wang
- College of Stomatology, Chongqing Medical University, Chongqing, China.,Chongqing Key Laboratory for Oral Diseases and Biomedical Sciences, Chongqing, China.,Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China
| | - Hong-Wei Dai
- College of Stomatology, Chongqing Medical University, Chongqing, China.,Chongqing Key Laboratory for Oral Diseases and Biomedical Sciences, Chongqing, China.,Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China
| | - Yu-Bo Fan
- Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Jin-Lin Song
- College of Stomatology, Chongqing Medical University, Chongqing, China.,Chongqing Key Laboratory for Oral Diseases and Biomedical Sciences, Chongqing, China.,Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China
| |
Collapse
|
5
|
Boitelle P, Tapie L, Mawussi B, Fromentin O. Evaluation of the marginal fit of CAD-CAM zirconia copings: Comparison of 2D and 3D measurement methods. J Prosthet Dent 2018; 119:75-81. [DOI: 10.1016/j.prosdent.2017.01.026] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2016] [Revised: 01/26/2017] [Accepted: 01/26/2017] [Indexed: 10/19/2022]
|
6
|
Ortega R, Gonzalo E, Gomez-Polo M, Lopez-Suarez C, Suarez MJ. SEM evaluation of the precision of fit of CAD/CAM zirconia and metal-ceramic posterior crowns. Dent Mater J 2017; 36:387-393. [PMID: 28367911 DOI: 10.4012/dmj.2016-305] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The purpose of this study is to evaluate the precision of fit of posterior crowns made from three commercial CAD/CAM zirconia ceramics and conventional metal-ceramic technique. The external and internal marginal fit of the crowns was evaluated using direct SEM-based measurements. The data were subjected to Kruskal-Wallis, multicomparison post hoc analysis and Wilcoxon rank sum tests (α=0.05). Significant differences were observed for the external (p<0.002) and the internal (p<0.0001) marginal evaluation among the groups. No differences were observed between the buccal and lingual surfaces for the external (p=0.34) and internal (p=0.55) evaluations. No differences were showed between the external and internal measurements (p=0.37). The accuracy of fit was within the range of clinical acceptance. The lowest discrepancies corresponded to the NobelProcera group for external (39.3±11.81 μm) and internal (41.09±7.54 µm) marginal fit. The results confirmed that destructive methods are not required to assess the marginal fit of dental prosthetic crowns.
Collapse
Affiliation(s)
- Rocio Ortega
- Department of Buccofacial Prostheses, Faculty of Odontology, University Complutense
| | - Esther Gonzalo
- Department of Buccofacial Prostheses, Faculty of Odontology, University Complutense
| | - Miguel Gomez-Polo
- Department of Buccofacial Prostheses, Faculty of Odontology, University Complutense
| | - Carlos Lopez-Suarez
- Department of Buccofacial Prostheses, Faculty of Odontology, University Complutense
| | - Maria J Suarez
- Department of Buccofacial Prostheses, Faculty of Odontology, University Complutense
| |
Collapse
|