1
|
Karaokutan I, Ayvaz I, Ozel GS. Effect of adhesives and mechanical surface treatments on the hard relining of CAD-CAM denture bases. J Prosthodont 2024. [PMID: 39215615 DOI: 10.1111/jopr.13934] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Revised: 07/28/2024] [Accepted: 08/17/2024] [Indexed: 09/04/2024] Open
Abstract
PURPOSE The aim of this study was to evaluate the impact of mechanical roughening, adhesive applications, and aging on the bonding between CAD-CAM denture base materials with distinct chemical contents and hard relining material. MATERIALS AND METHODS A total of 300 denture base specimens were produced by additive, subtractive, and conventional heat-polymerization techniques (N = 100). The specimens have been classified into five subgroups based on the particular surface treatments administered (n = 20): (1) Hard relining material's adhesive application (control); (2) Tungsten carbide bur application for 1 min, and hard reline material's adhesive application; (3) Airborne-particle abrasion (APA) with 110 μm Al2O3, and hard reline material's adhesive application; (4) Scotchbond Universal application; and (5) Visio.link application. Representative specimens from each subgroup were examined under a Scanning Electron Microscope (SEM). Subsequently, self-cure hard relining material was condensed in the center of the specimens. Half of the specimens were thermally aged with 5000 cycles at 5°C-55°C. The shear bond strength (SBS) test was performed, and failure loads were recorded. The data was evaluated by Robust ANOVA and Bonferroni test (p < 0.05). RESULTS No statistically significant difference was obtained between the production techniques (p = 0.051). The lowest SBS was observed in the control group among surface treatments, while mechanical surface treatments and universal adhesive showed the highest SBS for both aged and non-aged groups. Aging caused a significant decrease for all test groups (p = 0.001). CONCLUSIONS Mechanical surface treatments and universal adhesive applications are more effective for maintaining adhesion across all production techniques.
Collapse
Affiliation(s)
- Isil Karaokutan
- Department of Prosthodontics, Faculty of Dentistry, Pamukkale University, Denizli, Turkey
| | - Ilayda Ayvaz
- Department of Prosthodontics, Faculty of Dentistry, Pamukkale University, Denizli, Turkey
| | - Gulsum Sayin Ozel
- Department of Prosthodontics, Faculty of Dentistry, Istanbul Medipol University, Istanbul, Turkey
| |
Collapse
|
2
|
Modiga C, Stoia A, Leretter MT, Chiş AC, Ardelean AV, Azar ER, Kapor G, Pop DM, Romînu M, Sinescu C, Negruţiu ML, Petrescu EL. Mechanical Assessment of Denture Polymers Processing Technologies. J Funct Biomater 2024; 15:234. [PMID: 39194672 DOI: 10.3390/jfb15080234] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2024] [Revised: 08/01/2024] [Accepted: 08/20/2024] [Indexed: 08/29/2024] Open
Abstract
BACKGROUND Removable prostheses have seen a fundamental change recently because of advances in polymer materials, allowing improved durability and performance. Despite these advancements, notable differences still occur amongst various polymer materials and processing technologies, requiring a thorough grasp of their mechanical, physical, and therapeutic implications. The compressive strength of dentures manufactured using various technologies will be investigated. METHODS Traditional, injection molding, and additive and subtractive CAD/CAM processing techniques, all utilizing Polymethyl methacrylate (PMMA) as the main material, were used to construct complete dentures. The specimens underwent a compressive mechanical test, which reveals the differences in compressive strength. RESULTS All the specimens broke under the influence of a certain force, rather than yielding through flow, as is characteristic for plastic materials. For each specimen, the maximum force (N) was recorded, as well as the breaking energy. The mean force required to break the dentures for each processing technology is as follows: 4.54 kN for traditional packing-press technique, 17.92 kN for the injection molding technique, 1.51 kN for the additive CAD/CAM dentures, and 5.9 kN for the subtractive CAD/CAM dentures. CONCLUSIONS The best results were obtained in the case of the thermoplastic injection system and the worst results were recorded in the case of 3D printed samples. Another important aspect depicted is the standard deviation for each group, which reveal a relatively unstable property for the thermoplastic injected dentures. Good results here in terms of absolute property and stability of the property can be conferred to CAD/CAM milled group.
Collapse
Affiliation(s)
- Cristina Modiga
- Department of Prostheses Technology and Dental Materials, Faculty of Dental Medicine, University of Medicine and Pharmacy "Victor Babeş" Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timişoara, Romania
- Research Center in Dental Medicine Using Conventional and Alternative Technologies, University of Medicine and Pharmacy "Victor Babeş" Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timişoara, Romania
| | - Andreea Stoia
- Department of Mechanics and Strength of Materials, "Politehnica" University of Timisoara, 1 Mihai Viteazu Ave., 300222 Timişoara, Romania
| | - Marius Traian Leretter
- Department of Prosthodontics, Faculty of Dental Medicine, University of Medicine and Pharmacy "Victor Babeş" Timișoara, Bd. Revolutiei din 1989, Nr. 9, 300041 Timişoara, Romania
| | - Ana Codruţa Chiş
- Research Institute for Biosafety and Bioengineering, The King Michael I University of Life Sciences, 119 Aradului Road, 300645 Timişoara, Romania
| | - Andreea-Violeta Ardelean
- Research Center in Dental Medicine Using Conventional and Alternative Technologies, University of Medicine and Pharmacy "Victor Babeş" Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timişoara, Romania
| | - Edward-Ronald Azar
- Research Center in Dental Medicine Using Conventional and Alternative Technologies, University of Medicine and Pharmacy "Victor Babeş" Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timişoara, Romania
| | - Gabriel Kapor
- Department of Mechanics and Strength of Materials, "Politehnica" University of Timisoara, 1 Mihai Viteazu Ave., 300222 Timişoara, Romania
| | - Daniela-Maria Pop
- Department of Prostheses Technology and Dental Materials, Faculty of Dental Medicine, University of Medicine and Pharmacy "Victor Babeş" Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timişoara, Romania
- Research Center in Dental Medicine Using Conventional and Alternative Technologies, University of Medicine and Pharmacy "Victor Babeş" Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timişoara, Romania
| | - Mihai Romînu
- Department of Prostheses Technology and Dental Materials, Faculty of Dental Medicine, University of Medicine and Pharmacy "Victor Babeş" Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timişoara, Romania
- Research Center in Dental Medicine Using Conventional and Alternative Technologies, University of Medicine and Pharmacy "Victor Babeş" Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timişoara, Romania
| | - Cosmin Sinescu
- Department of Prostheses Technology and Dental Materials, Faculty of Dental Medicine, University of Medicine and Pharmacy "Victor Babeş" Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timişoara, Romania
- Research Center in Dental Medicine Using Conventional and Alternative Technologies, University of Medicine and Pharmacy "Victor Babeş" Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timişoara, Romania
| | - Meda-Lavinia Negruţiu
- Department of Prostheses Technology and Dental Materials, Faculty of Dental Medicine, University of Medicine and Pharmacy "Victor Babeş" Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timişoara, Romania
- Research Center in Dental Medicine Using Conventional and Alternative Technologies, University of Medicine and Pharmacy "Victor Babeş" Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timişoara, Romania
| | - Emanuela-Lidia Petrescu
- Department of Prostheses Technology and Dental Materials, Faculty of Dental Medicine, University of Medicine and Pharmacy "Victor Babeş" Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timişoara, Romania
- Research Center in Dental Medicine Using Conventional and Alternative Technologies, University of Medicine and Pharmacy "Victor Babeş" Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timişoara, Romania
| |
Collapse
|
3
|
El-Hussein IG. Effect of Adding Different Concentrations of Silver Nanoparticles on Flexural Strength and Microhardness of Different Denture Base Materials. J Contemp Dent Pract 2024; 25:417-423. [PMID: 39364839 DOI: 10.5005/jp-journals-10024-3688] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/05/2024]
Abstract
AIM This study aimed to evaluate the effect of adding different concentrations of silver nanoparticles (AgNPs) on the flexural strength and microhardness of various denture base materials. MATERIALS AND METHODS For this study, a total of 60 specimens were used and divided into equal groups. The first group consisted of heat-cured acrylic resin (Vertex-Germany), while the second group consisted of thermoplastic resin (Breflex 2nd edition, Germany). The samples were created using a split brass mold with dimensions of 65 × 10 × 2.5 mm, in accordance with the specifications of the American Dental Association (specifically No. 12 for flexural and microhardness). Following this, the samples were divided into three groups (A, B, and C) based on different concentrations of AgNPs (0, 2, and 5%). The flexural and microhardness of the samples were assessed using a universal testing machine and the Vickers hardness test, respectively. The data were gathered, organized, and analyzed using statistical methods. RESULTS The flexural strength findings showed a significant difference between the two groups. Also, there was a considerable decrease in the average value of the acrylic group as the concentrations of AgNPs rose, while the flexural strength of the thermoplastic group notably improved. Regarding microhardness, the results showed a significant difference between the two groups. It showed that the mean value of both groups increased with increasing concentrations of AgNPs. CONCLUSION Within the limitations of laboratory testing conditions of this study, it was discovered that AgNPs negatively impact the flexural strength of acrylic resins. Furthermore, an increase in the concentration of AgNPs was found to be directly related to the flexural strength of thermoplastic resin and the microhardness of both groups. CLINICAL SIGNIFICANCE The concentration of AgNPs has a significant impact on certain mechanical properties of denture base materials, but it is important to consider their potential toxicity. How to cite this article: El-Hussein IG. Effect of Adding Different Concentrations of Silver Nanoparticles on Flexural Strength and Microhardness of Different Denture Base Materials. J Contemp Dent Pract 2024;25(5):417-423.
Collapse
Affiliation(s)
- Ibrahim Gamal El-Hussein
- Department of Removable Prosthodontics, Faculty of Dentistry, Sinai University (Kantara), Cairo, Egypt, Phone: +01156674887, e-mail:
| |
Collapse
|
4
|
Chuchulska B, Dimitrova M, Vlahova A, Hristov I, Tomova Z, Kazakova R. Comparative Analysis of the Mechanical Properties and Biocompatibility between CAD/CAM and Conventional Polymers Applied in Prosthetic Dentistry. Polymers (Basel) 2024; 16:877. [PMID: 38611135 PMCID: PMC11013798 DOI: 10.3390/polym16070877] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2024] [Revised: 03/14/2024] [Accepted: 03/19/2024] [Indexed: 04/14/2024] Open
Abstract
Modern media often portray CAD/CAM technology as widely utilized in the fabrication of dental prosthetics. This study presents a comparative analysis of the mechanical properties and biocompatibility of CAD/CAM (Computer-Aided Design/Computer-Aided Manufacturing) polymers and conventional polymers commonly utilized in prosthetic dentistry. With the increasing adoption of CAD/CAM technology in dental laboratories and practices, understanding the differences in material properties is crucial for informed decision-making in prosthodontic treatment planning. Through a narrative review of the literature and empirical data, this study evaluates the mechanical strength, durability, esthetics, and biocompatibility of CAD/CAM polymers in comparison to traditional polymers. Furthermore, it examines the implications of these findings on the clinical outcomes and long-term success of prosthetic restorations. The results provide valuable insights into the advantages and limitations of CAD/CAM polymers, informing clinicians and researchers about their suitability for various dental prosthetic applications. This study underscores the considerable advantages of CAD/CAM polymers over conventional ones in terms of mechanical properties, biocompatibility, and esthetics for prosthetic dentistry. CAD/CAM technology offers improved mechanical strength and durability, potentially enhancing the long-term performance of dental prosthetics, while the biocompatibility of these polymers makes them suitable for a broad patient demographic, reducing the risk of adverse reactions. The practical implications of these findings for dental technicians and dentists are significant, as understanding these material differences enables tailored treatment planning to meet individual patient needs and preferences. Integration of CAD/CAM technology into dental practices can lead to more predictable outcomes and heightened patient satisfaction with prosthetic restorations.
Collapse
Affiliation(s)
- Bozhana Chuchulska
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (I.H.); (Z.T.); (R.K.)
| | - Mariya Dimitrova
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (I.H.); (Z.T.); (R.K.)
| | - Angelina Vlahova
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (I.H.); (Z.T.); (R.K.)
- CAD/CAM Center of Dental Medicine, Research Institute, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria
| | - Ilian Hristov
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (I.H.); (Z.T.); (R.K.)
| | - Zlatina Tomova
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (I.H.); (Z.T.); (R.K.)
| | - Rada Kazakova
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (I.H.); (Z.T.); (R.K.)
- CAD/CAM Center of Dental Medicine, Research Institute, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria
| |
Collapse
|
5
|
Karaokutan I, Ayvaz I. Effect of various surface treatments on relining bond strength of CAD-CAM denture base materials. J Prosthodont 2024. [PMID: 38369895 DOI: 10.1111/jopr.13831] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Accepted: 02/01/2024] [Indexed: 02/20/2024] Open
Abstract
PURPOSE The aim of this study was to analyze the impact of various surface treatments and production methods on the shear bond strength (SBS) between reline material and denture base resins. MATERIALS AND METHODS One-hundred-twenty specimens were produced using conventional heat-polymerization, subtractive, and additive techniques. Each group consisted of 40 specimens. The specimens were divided into four subgroups, each with 10 samples, for surface treatments. These subgroups were: (1) Control-only monomer application, (2) 50 μm airborne-particle abrasion, (3) 110 μm airborne-particle abrasion, and (4) Roughening with tungsten carbide bur. Representative specimens from each subgroup were examined under SEM. Then, auto-polymerized resin was condensed in the center of the specimens. Specimens were subjected to thermal aging (5000 cycles at 5-55°C). The SBS test was conducted and failure loads were recorded. The data were evaluated by two-way ANOVA and Tukey pairwise multiple comparisons method (p < 0.05). RESULTS The additively produced group showed significantly lower SBS than conventional and subtractive groups (p < 0.001), with no significant differences between the subtractive and conventional groups. Specimens that underwent monomer application only showed the lowest SBS among surface treatments, while 50 μm airborne-particle abrasion showed the highest SBS. Based on the partial eta-squared analysis results, the surface treatment mainly impacted SBS. CONCLUSIONS Among the surface treatment methods, treating denture bases with 50 μm airborne-particle abrasion is more effective for maintaining adhesion, especially in the additive technique.
Collapse
Affiliation(s)
- Isil Karaokutan
- Department of Prosthodontics, Faculty of Dentistry, Pamukkale University, Denizli, Turkey
| | - Ilayda Ayvaz
- Department of Prosthodontics, Faculty of Dentistry, Pamukkale University, Denizli, Turkey
| |
Collapse
|
6
|
Le Bars P, Bandiaky ON, Le Guéhennec L, Clouet R, Kouadio AA. Different Polymers for the Base of Removable Dentures? Part I: A Narrative Review of Mechanical and Physical Properties. Polymers (Basel) 2023; 15:3495. [PMID: 37688123 PMCID: PMC10490543 DOI: 10.3390/polym15173495] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 08/14/2023] [Accepted: 08/17/2023] [Indexed: 09/10/2023] Open
Abstract
Even before considering their introduction into the mouth, the choice of materials for the optimization of the prosthesis depends on specific parameters such as their biocompatibility, solidity, resistance, and longevity. In the first part of this two-part review, we approach the various mechanical characteristics that affect this choice, which are closely related to the manufacturing process. Among the materials currently available, it is mainly polymers that are suitable for this use in this field. Historically, the most widely used polymer has been polymethyl methacrylate (PMMA), but more recently, polyamides (nylon) and polyether ether ketone (PEEK) have provided interesting advantages. The incorporation of certain molecules into these polymers will lead to modifications aimed at improving the mechanical properties of the prosthetic bases. In the second part of the review, the safety aspects of prostheses in the oral ecosystem (fragility of the undercuts of soft/hard tissues, neutral pH of saliva, and stability of the microbiota) are addressed. The microbial colonization of the prosthesis, in relation to the composition of the material used and its surface conditions (roughness, hydrophilicity), is of primary importance. Whatever the material and manufacturing process chosen, the coating or finishes dependent on the surface condition remain essential (polishing, non-stick coating) for limiting microbial colonization. The objective of this narrative review is to compile an inventory of the mechanical and physical properties as well as the clinical conditions likely to guide the choice between polymers for the base of removable prostheses.
Collapse
Affiliation(s)
- Pierre Le Bars
- Department of Prosthetic Dentistry, Faculty of Dentistry, Nantes University, 1 Place Alexis Ricordeau, 44042 Nantes, France; (L.L.G.); (R.C.); (A.A.K.)
- Oniris, CHU Nantes, INSERM, Regenerative Medicine and Skeleton, RMeS, Nantes Université, UMR 1229, 44000 Nantes, France;
| | - Octave Nadile Bandiaky
- Oniris, CHU Nantes, INSERM, Regenerative Medicine and Skeleton, RMeS, Nantes Université, UMR 1229, 44000 Nantes, France;
| | - Laurent Le Guéhennec
- Department of Prosthetic Dentistry, Faculty of Dentistry, Nantes University, 1 Place Alexis Ricordeau, 44042 Nantes, France; (L.L.G.); (R.C.); (A.A.K.)
- Oniris, CHU Nantes, INSERM, Regenerative Medicine and Skeleton, RMeS, Nantes Université, UMR 1229, 44000 Nantes, France;
| | - Roselyne Clouet
- Department of Prosthetic Dentistry, Faculty of Dentistry, Nantes University, 1 Place Alexis Ricordeau, 44042 Nantes, France; (L.L.G.); (R.C.); (A.A.K.)
- Oniris, CHU Nantes, INSERM, Regenerative Medicine and Skeleton, RMeS, Nantes Université, UMR 1229, 44000 Nantes, France;
| | - Alain Ayepa Kouadio
- Department of Prosthetic Dentistry, Faculty of Dentistry, Nantes University, 1 Place Alexis Ricordeau, 44042 Nantes, France; (L.L.G.); (R.C.); (A.A.K.)
- Department of Prosthetic Dentistry, Faculty of Dentistry, University Hospital Center, Abidjan P.O. Box 612, Côte d’Ivoire
| |
Collapse
|
7
|
Patil S, Licari FW, Bhandi S, Awan KH, Badnjević A, Belli V, Cervino G, Minervini G. The Cytotoxic Effect of Thermoplastic Denture Base Resins: A Systematic Review. J Funct Biomater 2023; 14:411. [PMID: 37623656 PMCID: PMC10455636 DOI: 10.3390/jfb14080411] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 07/06/2023] [Accepted: 07/14/2023] [Indexed: 08/26/2023] Open
Abstract
Partial or complete dentures are constructed from thermoplastic resins that are thermally processed and molded. This review examines the presently available evidence for the cytotoxicity of thermoplasticized denture base resins on human gingival epithelial cells, adipose cells, and fibroblasts; human amnion fibroblasts; and mouse fibroblasts. Electronic searches were performed on PubMed, Scopus, Web of Science, and Google Scholar databases to identify relevant articles to be included in the review until September 2022. Clinical, in vivo, and in vitro studies in English language were searched for. The quality of the studies was assessed using the Toxicological data Reliability Assessment tool (ToxRTool) developed by the European Commission's Joint Research Centre. GRADE assessment was used to evaluate the certainty of evidence. Seven in vitro studies were included in the review. The overall risk of bias was determined to be high, with the majority of studies assessed found to be reliable with restrictions or not reliable. Only two studies were considered reliable without restrictions based on ToxRTool assessment. The effect of thermoplastic denture base resins on viability and cell adherence of human gingival or amnion fibroblasts and mouse fibroblasts (L929s) is not significant. Conditioned media from unpolished specimens of resins were significantly more toxic to cultured cells than those from polished specimens. This may be of concern in cases of poor post-processing of dentures. Based on the limited evidence available, there is low-certainty evidence that thermoplastic denture base resins appear to be biocompatible and show insignificant cytotoxicity. Further well-designed trials adhering to standard reporting guidelines and using objective measures are necessary before outlining universal guidelines for best practice. Long-term in vivo and clinical assessment is necessary to corroborate laboratory findings with clinical outcomes. Denture base resins are in constant contact with oral tissues, and cytotoxic components released by the resins may irritate or inflame the tissues or provoke an allergic response.
Collapse
Affiliation(s)
- Shankargouda Patil
- College of Dental Medicine, Roseman University of Health Sciences, South Jordan, UT 84095, USA (S.B.)
| | - Frank W. Licari
- College of Dental Medicine, Roseman University of Health Sciences, South Jordan, UT 84095, USA (S.B.)
| | - Shilpa Bhandi
- College of Dental Medicine, Roseman University of Health Sciences, South Jordan, UT 84095, USA (S.B.)
| | - Kamran H. Awan
- College of Dental Medicine, Roseman University of Health Sciences, South Jordan, UT 84095, USA (S.B.)
| | - Almir Badnjević
- Verlab Research Institute for Biomedical Engineering, Medical Devices and Artificial Intelligence, 71000 Sarajevo, Bosnia and Herzegovina;
| | - Valentina Belli
- Department of Precision Medicine, Università degli Studi della Campania “Luigi Vanvitelli”, 80131 Naples, Italy
| | - Gabriele Cervino
- Department of Biomedical and Dental Sciences, Morphological and Functional Images, University of Messina, G. Martino Polyclinic, 98100 Messina, Italy
| | - Giuseppe Minervini
- Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Campania, Luigi Vanvitelli, 80138 Naples, Italy;
| |
Collapse
|
8
|
Khan AA, Fareed MA, Alshehri AH, Aldegheishem A, Alharthi R, Saadaldin SA, Zafar MS. Mechanical Properties of the Modified Denture Base Materials and Polymerization Methods: A Systematic Review. Int J Mol Sci 2022; 23:5737. [PMID: 35628546 PMCID: PMC9143457 DOI: 10.3390/ijms23105737] [Citation(s) in RCA: 24] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2022] [Revised: 05/15/2022] [Accepted: 05/19/2022] [Indexed: 12/22/2022] Open
Abstract
Amidst growing technological advancements, newer denture base materials and polymerization methods have been introduced. During fabrication, certain mechanical properties are vital for the clinical longevity of the denture base. This systematic review aimed to explore the effect of newer denture base materials and/or polymerization methods on the mechanical properties of the denture base. An electronic database search of English peer-reviewed published papers was conducted using related keywords from 1 January 2011, up until 31 December 2021. This systematic review was based on guidelines proposed by the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). The search identified 579 papers. However, the inclusion criteria recognized 22 papers for eligibility. The risk of bias was moderate in all studies except in two where it was observed as low. Heat cure polymethyl methacrylate (PMMA) and compression moulding using a water bath is still a widely used base material and polymerization technique, respectively. However, chemically modified PMMA using monomers, oligomers, copolymers and cross-linking agents may have a promising result. Although chemically modified PMMA resin might enhance the mechanical properties of denture base material, no clear inferences can be drawn about the superiority of any polymerization method other than the conventional compression moulding technique.
Collapse
Affiliation(s)
- Aftab Ahmed Khan
- Dental Biomaterials Research Chair, College of Applied Medical Sciences, King Saud University, Riyadh 11451, Saudi Arabia
| | - Muhammad Amber Fareed
- Department of Restorative Dentistry, College of Dentistry, Gulf Medical University, Ajman P.O. Box 4184, United Arab Emirates;
| | - Abdulkarim Hussain Alshehri
- Department of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia;
| | - Alhanoof Aldegheishem
- Department of Clinical Dental Science, College of Dentistry, Princess Nourah bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia; (A.A.); (R.A.)
| | - Rasha Alharthi
- Department of Clinical Dental Science, College of Dentistry, Princess Nourah bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia; (A.A.); (R.A.)
| | - Selma A. Saadaldin
- Prosthodontics Division, Schulich School of Medicine and Dentistry, Western University, London, ON N6A 5B9, Canada;
| | - Muhammad Sohail Zafar
- Department of Restorative Dentistry, College of Dentistry, Taibah University, Al Madinah Al Munawarah, Medina 42353, Saudi Arabia;
- Department of Dental Materials, Islamic International Dental College, Riphah International University, Islamabad 46000, Pakistan
| |
Collapse
|
9
|
Bapat RA, Parolia A, Chaubal T, Dharamadhikari S, Abdulla AM, Sakkir N, Arora S, Bapat P, Sindi AM, Kesharwani P. Recent update on potential cytotoxicity, biocompatibility and preventive measures of biomaterials used in dentistry. Biomater Sci 2021; 9:3244-3283. [PMID: 33949464 DOI: 10.1039/d1bm00233c] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
Dental treatment is provided for a wide variety of oral health problems like dental caries, periodontal diseases, periapical infections, replacement of missing teeth and orthodontic problems. Various biomaterials, like composite resins, amalgam, glass ionomer cement, acrylic resins, metal alloys, impression materials, bone grafts, membranes, local anaesthetics, etc., are used for dental applications. The physical and chemical characteristics of these materials influence the outcome of dental treatment. It also impacts on the biological, allergic and toxic potential of biomaterials. With innovations in science and their positive results, there is also a need for awareness about the biological risks of these biomaterials. The aim of dental treatment is to have effective, yet safe, and long-lasting results for the benefit of patients. For this, it is important to have a thorough understanding of biomaterials and their effects on local and systemic health. Materials used in dentistry undergo a series of analyses before their oral applications. To the best of our knowledge, this is the first and original review that discusses the reasons for and studies on the toxicity of commonly used biomaterials for applications in dentistry. It will help clinicians to formulate a methodical approach for the selection of dental biomaterials, thus providing an awareness for forecasting their risk of toxic reactions.
Collapse
Affiliation(s)
- Ranjeet Ajit Bapat
- Faculty, Division of Clinical Dentistry, School of Dentistry, International Medical University Kuala Lumpur, 126, Jalan Jalil Perkasa 19, Bukit Jalil, 57000 Bukit Jalil, Wilayah Persekutuan Kuala Lumpur, Malaysia
| | - Abhishek Parolia
- Faculty, Division of Clinical Dentistry, School of Dentistry, International Medical University Kuala Lumpur, 126, Jalan Jalil Perkasa 19, Bukit Jalil, 57000 Bukit Jalil, Wilayah Persekutuan Kuala Lumpur, Malaysia
| | - Tanay Chaubal
- Faculty, Division of Clinical Dentistry, School of Dentistry, International Medical University Kuala Lumpur, 126, Jalan Jalil Perkasa 19, Bukit Jalil, 57000 Bukit Jalil, Wilayah Persekutuan Kuala Lumpur, Malaysia
| | | | - Anshad Mohamed Abdulla
- Faculty, Department of Pediatric Dentistry and Orthodontic Sciences, College of Dentistry, King Khalid University, Abha, Kingdom of Saudi Arabia
| | - Nasil Sakkir
- Registrar Endodontist, Central Security Hospital, Abha, Kingdom of Saudi Arabia
| | - Suraj Arora
- Faculty, Department of Restorative Dental Sciences, College of Dentistry, King Khalid University, Abha, Kingdom of Saudi Arabia
| | - Prachi Bapat
- Dentist, Modern Dental College, Indore 453112, Madhya Pradesh, India
| | - Amal M Sindi
- Faculty, Oral Diagnostic Sciences Department, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Prashant Kesharwani
- Faculty, Department of Pharmaceutics, School of Pharmaceutical Education and Research, Jamia Hamdard, New Delhi, 110062, India.
| |
Collapse
|
10
|
Comparison of Fracture Resistance in Thermal and Self-Curing Acrylic Resins-An In Vitro Study. Polymers (Basel) 2021; 13:polym13081234. [PMID: 33920377 PMCID: PMC8069947 DOI: 10.3390/polym13081234] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2021] [Revised: 04/08/2021] [Accepted: 04/09/2021] [Indexed: 02/03/2023] Open
Abstract
Thermal and self-curing acrylic resins are frequently and versatilely used in dental medicine since they are biocompatible, have no flavor or odor, have satisfactory thermal qualities and polishing capacity, and are easy and fast. Thus, given their widespread use, their fracture resistance behavior is especially important. In this research work, we comparatively analyzed the fracture resistance capacity of thermo and self-curing acrylic resins in vitro. Materials and Methods: Five prosthesis bases were created for each of the following acrylic resins: Lucitone®, ProBase®, and Megacryl®, which were submitted to different forces through the use of the CS® Dental Testing Machine, usually mobilized in the context of fatigue tests. To this end, a point was defined in the center of the anterior edge of the aforementioned acrylic resin bases, for which the peak tended until a fracture occurred. Thermosetting resins were, on average, more resistant to fracture than self-curable resins, although the difference was not statistically significant. The thermosetting resins of the Lucitone® and Probase® brands demonstrated behavior that was more resistant to fracture than the self-curing homologues, although the difference was not statistically significant. Thermosetting resins tended to be, on average, more resistant to fracture and exhibited the maximum values for impact strength, compressive strength, tensile strength, hardness, and dimensional accuracy than self-curing resins, regardless of brand.
Collapse
|
11
|
Machado-Santos L, Silikas N, Baroudi K, Sinhoreti MAC, Brandt WC, Liporoni PCS. Mechanical performance of experimental acrylic resins modified by nanoparticles after chemical and mechanical degradation. J Clin Exp Dent 2020; 12:e1157-e1163. [PMID: 33282137 PMCID: PMC7700787 DOI: 10.4317/jced.57265] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Accepted: 07/02/2020] [Indexed: 11/05/2022] Open
Abstract
Background Different materials have been incorporated into the polymethylmethacrylate matrix to improve its performance. The aim of this study was to evaluate the degree of conversion (DC), the flexural strength (FS), the elasticity modulus (EM), and the effect of exposure to food-simulating liquids prior to brushing simulation on the gloss loss (GL) of experimental acrylic resins modified by nanoparticles.
Material and Methods Three different types of nanoparticles; silicon oxide (SiO2), cerium oxide (CeO2) and titanium oxide (TiO2) were added to a poly (methylmethacrylate) matrix, in proportions of 0.5wt%, 1wt% and 3wt% each, forming nine experimental groups. The acrylic resin was also tested as a control group. DC was investigated using Fourier transform infrared spectroscopy (FTIR). A three-point bending test was used for FS and EM. GL after chemical degradation and simulated brushing was evaluated using a glossmeter. Data were submitted to one and two-way ANOVA followed by Duncan’s post hoc test (α=0.05).
Results All nanoparticle-modified groups showed higher values of DC. Ce1% showed higher values of FS and EM. All other groups showed similar or lower physical-mechanical properties (FS, EM, GL). Regarding type and wt%, CeO2 and TiO2 groups had better performances and were similar to each other.
Conclusions Incorporating metal nanoparticles, especially CeO2, could improve the physical properties of the dental materials. Key words:Polymethylmetacrylate, degree of conversion, flexural strength, elasticity modulus, gloss loss.
Collapse
Affiliation(s)
- Luciana Machado-Santos
- Department of Restorative Dentistry, School of Dentistry, University of Taubaté, Taubaté, Brazil
| | - Nicolaos Silikas
- Dentistry, School of Medical Sciences, University of Manchester, Manchester M13 9PL, UK
| | - Kusai Baroudi
- Postgraduate Program, School of Dentistry, University of Taubaté, Taubaté, Brazil
| | | | | | | |
Collapse
|
12
|
HAYRAN Y, KESKIN Y. Flexural strength of polymethyl methacrylate copolymers as a denture base resin. Dent Mater J 2019; 38:678-686. [DOI: 10.4012/dmj.2018-393] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Yeliz HAYRAN
- Tokat Gaziosmanpasa University, Department of Prosthodontics, Faculty of Dentistry
| | - Yasemin KESKIN
- Ankara University, Department of Prosthodontics, Faculty of Dentistry
| |
Collapse
|
13
|
Ozkir SE, Yilmaz B, Unal SM, Culhaoglu A, Kurkcuoglu I. Effect of heat polymerization conditions and microwave on the flexural strength of polymethyl methacrylate. Eur J Dent 2018; 12:116-119. [PMID: 29657535 PMCID: PMC5883462 DOI: 10.4103/ejd.ejd_199_17] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Objective The objective of this study is the effect of different heat polymerization conditions on the strength of polymethyl methacrylate (PMMA) resin base is unknown. Distinguishing one method that provides improved mechanical properties may be beneficial to the clinical success of complete and partial dentures and overdentures. The purpose of this study was to evaluate the effect of different polymerization methods on the flexural strength of a dental PMMA resin. Materials and Methods Forty PMMA specimens (64 mm × 10 mm × 4 mm) were prepared with 4 different polymerization methods (n = 10); heat polymerization at 74°C for 9 h, at 100°C for 40 min, and with 620 kPa pressure at 100°C for 20 min. The remaining group of specimens was microwave polymerized at 180 W for 6 min. All specimens were thermocycled at 5°C and 55°C for 5000 times. Three-point flexure test was used to measure the flexural strength of specimens. One-way ANOVA and Tukey Honestly Significant Difference were applied to analyze the differences in flexural strengths (α = 0.05). Results The flexural strength of heat-polymerized groups was similar. The flexural strength of microwave polymerized group was significantly different and lower than the other groups (P < 0.05). Conclusion Polymerizing conventional heat-polymerizing PMMA resin with microwave energy resulted in a significant decrease in flexural strength. The results of this study suggest that clinicians may benefit from using heat polymerization when processing PMMA denture bases instead of microvawe polymerization when tested brand is used.
Collapse
Affiliation(s)
- Serhat Emre Ozkir
- Department of Prosthodontics, Faculty of Dentistry, Afyon Kocatepe University, Afyonkarahisar, Turkiye
| | - Burak Yilmaz
- Division of Restorative Sciences and Prosthodontics, College of Dentistry, The Ohio State University, Columbus, Ohio, USA
| | - Server Mutluay Unal
- Department of Prosthodontics, Faculty of Dentistry, Afyon Kocatepe University, Afyonkarahisar, Turkiye
| | - Ahmet Culhaoglu
- Department of Prosthodontics, Faculty of Dentistry, Kirikkale University, Kirikkale, Turkiye
| | - Isin Kurkcuoglu
- Department of Prosthodontics, Faculty of Dentistry, Suleyman Demirel University, Isparta, Turkiye
| |
Collapse
|
14
|
Lee JH, Jun SK, Kim SC, Okubo C, Lee HH. Investigation of the cytotoxicity of thermoplastic denture base resins. J Adv Prosthodont 2017; 9:453-462. [PMID: 29279765 PMCID: PMC5741449 DOI: 10.4047/jap.2017.9.6.453] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2016] [Revised: 03/08/2017] [Accepted: 08/20/2017] [Indexed: 11/08/2022] Open
Abstract
PURPOSE The purpose of this study was to investigate the in vitro cytotoxicity of thermoplastic denture base resins and to identify the possible adverse effects of these resins on oral keratinocytes in response to hot water/food intake. MATERIALS AND METHODS Six dental thermoplastic resin materials were evaluated: three polyamide materials (Smile tone, ST; Valplast, VP; and Luciton FRS, LF), two acrylic materials (Acrytone, AT; and Acryshot, AS), and one polypropylene resin material (Unigum, UG). One heat-polymerized acrylic resin (Vertex RS, RS) was chosen for comparison. After obtaining extracts from specimens of the denture resin materials (Φ=10 mm and d=2 mm) under different extraction conditions (37℃ for 24 hours, 70℃ for 24 hours, and 121℃ for 1 hour), the extracts (50%) or serial dilutions (25%, 12.5%, and 6.25%) in distilled water were co-cultured for 24 hours with immortalized human oral keratinocytes (IHOKs) or mouse fibroblasts (L929s) for the cytotoxicity assay described in ISO 10993. RESULTS Greater than 70% viability was detected under all test conditions. Significantly lower IHOK and L929 viability was detected in the 50% extract from the VP (70℃) and AT (121℃) samples (P<.05), but only L929 showed reduced viability in the 50% and 25% extract from LF (37℃) (P<.05). CONCLUSION Extracts obtained from six materials under different extraction conditions (37℃, 70℃, and 121℃) did not exhibit severe cytotoxicity (less than 70% viability), although their potential risk to oral mucosa at high temperatures should not be ignored.
Collapse
Affiliation(s)
- Jung-Hwan Lee
- Institute of Tissue Regeneration Engineering (ITREN), Dankook University, Cheonan, Republic of Korea
| | - Soo-Kyung Jun
- Institute of Tissue Regeneration Engineering (ITREN), Dankook University, Cheonan, Republic of Korea.,Department of Biomaterials Science, College of Dentistry, Dankook University, Cheonan, Republic of Korea
| | - Si-Chul Kim
- Department of Biomaterials Science, College of Dentistry, Dankook University, Cheonan, Republic of Korea
| | - Chikahiro Okubo
- Department of Removable Prosthodontics, Tsurumi University School of Dental Medicine, Tsurumi-ku, Yokohama-shi, Japan
| | - Hae-Hyoung Lee
- Institute of Tissue Regeneration Engineering (ITREN), Dankook University, Cheonan, Republic of Korea.,Department of Biomaterials Science, College of Dentistry, Dankook University, Cheonan, Republic of Korea
| |
Collapse
|
15
|
Evaluation of Light-Activated Provisional Resin Materials for Periodontal Soft Tissue Management. BIOMED RESEARCH INTERNATIONAL 2016; 2016:1209705. [PMID: 27672651 PMCID: PMC5031816 DOI: 10.1155/2016/1209705] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/03/2016] [Accepted: 08/17/2016] [Indexed: 11/30/2022]
Abstract
The purpose of this study was to determine mechanical properties using a compressive test with cylinder specimen (h = 6 mm and ϕ = 4 mm) as well as cytotoxicity using elutes from disk specimen (ϕ = 10 mm and h = 2 mm) against human gingival fibroblasts and oral keratinocytes with light-activated provisional resin materials (Revotek LC and Luxatemp Solar) compared to chemically activated counterpart (Snap, Trim II, and Jet). Significantly increased compressive strength (210~280 MPa) was detected in light-activated products compared to chemically activated ones (20~65 MPa, P < 0.05) and similar compressive modulus was detected in both types (0.8~1.5 and 0.5~1.3 GPa). Simultaneously, the light-activated products showed less adverse effects on the periodontal soft tissue cells in any polymerization stage compared to the chemically activated products. Particularly, chemically activated products had significantly greater adverse effects during the “polymerizing” phase compared to those that were “already set” (P < 0.05), as shown in confocal microscopic images of live and dead cells. In conclusion, light-activated provisional resin materials have better mechanical properties as well as biocompatibility against two tested types of oral cells compared to the chemically activated counterpart, which are considered as more beneficial choice for periodontal soft tissue management.
Collapse
|
16
|
Abebe W, West D, Rueggeberg FA, Pashley D, Mozaffari MS. Effects of acrylic resin monomers on porcine coronary artery reactivity. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2016; 27:986-1002. [PMID: 27132475 DOI: 10.1080/09205063.2016.1175775] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
The purpose of the present investigation was to assess the reactivity of porcine coronary arteries under in vitro conditions following their exposure to methyl methacrylate (MMA) and hydroxyethyl methacrylate (HEMA) monomers. Confirming previous studies using rat aortas, both MMA and HEMA induced acute/direct relaxation of coronary ring preparations, which was partly dependent on the endothelium. With prolonged tissue exposure, both monomers caused time- and concentration-dependent inhibition of receptor-mediated contraction of the vascular smooth muscle caused by prostaglandin F2∝ (PGF2∝), with HEMA causing more inhibition than MMA. Hydroxyethyl methacrylate, but not MMA, also produced impairment of non-receptor-mediated contraction of the coronary smooth muscle induced by KCl. On the other hand, neither HEMA nor MMA altered relaxation of the smooth muscle produced by the direct-acting pharmacological agent, sodium nitroprusside (SNP). While exposure to HEMA impaired endothelium-dependent vasorelaxation caused by bradykinin (BK), MMA markedly enhanced this endothelial-mediated response of the arteries. The enhanced endothelial response produced by MMA was linked to nitric oxide (NO) release. In conclusion, with prolonged tissue exposure, MMA causes less pronounced effects/adverse consequences on coronary smooth muscle function relative to the effect of HEMA, while enhancing vasorelaxation associated with release of NO from the endothelium. Accordingly, MMA-containing resin materials appear to be safer for human applications than materials containing HEMA.
Collapse
Affiliation(s)
- Worku Abebe
- a Department of Oral Biology , Dental College of Georgia, Augusta University , Augusta , GA , USA
| | - Daniel West
- b Periodontal Section , DentFirst Dental Care , Norcross , GA , USA
| | - Frederick A Rueggeberg
- c Section of Dental Material, Department of Oral Rehabilitation , Dental College of Georgia, Augusta University , Augusta , GA , USA
| | - David Pashley
- a Department of Oral Biology , Dental College of Georgia, Augusta University , Augusta , GA , USA
| | - Mahmood S Mozaffari
- a Department of Oral Biology , Dental College of Georgia, Augusta University , Augusta , GA , USA
| |
Collapse
|
17
|
Lee DH, Mai HN, Yang JC, Kwon TY. The effect of 4,4'-bis(N,N-diethylamino) benzophenone on the degree of conversion in liquid photopolymer for dental 3D printing. J Adv Prosthodont 2015; 7:386-91. [PMID: 26576255 PMCID: PMC4644780 DOI: 10.4047/jap.2015.7.5.386] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2015] [Revised: 08/20/2015] [Accepted: 08/27/2015] [Indexed: 11/18/2022] Open
Abstract
PURPOSE The purpose of this preliminary study was to investigate the effects of adding 4,4'-bis(N,N-diethylamino) benzophenone (DEABP) as a co-initiator to a binary photoinitiating system (camphorquinone-amine) to analyze on the degree of conversion (DC) of a light-cured resin for dental 3D printing. MATERIALS AND METHODS Cylindrical specimens (N=60, n=30 per group, ø5 mm × 1 mm) were fabricated using bisphenol A glycerolate dimethacrylate (BisGMA) both with and without DEABP. The freshly mixed resins were exposed to light in a custom-made closed chamber with nine light-emitting diode lamps (wavelength: 405 nm; power: 840 mW/cm2) for polymerization at each incidence of light-irradiation at 10, 30, 60, 180, and 300 seconds, while five specimens at a time were evaluated at each given irradiation point. Fourier-transform infrared (FTIR) spectroscopy was used to measure the DC values of the resins. Two-way analysis of variance and the Duncan post hoc test were used to analyze statistically significant differences between the groups and given times (α=.05). RESULTS In the DEABP-containing resin, the DC values were significantly higher at all points in time (P<.001), and also the initial polymerization velocity was faster than in the DEABP-free resin. CONCLUSION The addition of DEABP significantly enhanced the DC values and, thus, could potentially become an efficient photoinitiator when combined with a camphorquinone-amine system and may be utilized as a more advanced photopolymerization system for dental 3D printing.
Collapse
Affiliation(s)
- Du-Hyeong Lee
- Department of Prosthodontics, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea
| | - Hang Nga Mai
- Department of Prosthodontics, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea
| | - Jin-Chul Yang
- Department of Polymer Science & Engineering, School of Applied Chemical Engineering, Kyungpook National University, Daegu, Republic of Korea
| | - Tae-Yub Kwon
- Department of Dental Biomaterials, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea
| |
Collapse
|