1
|
Marcomini N, Albaricci MCDC, Costa JLDSG, Besegato JF, Godoy EF, Dantas AAR, Kuga MC. Effects of alpha-tocopherol antioxidant on fracture strength and adhesion of endodontically treated teeth restored after dental bleaching. Eur J Oral Sci 2024; 132:e12965. [PMID: 38115770 DOI: 10.1111/eos.12965] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Accepted: 11/14/2023] [Indexed: 12/21/2023]
Abstract
This study evaluated the effect of different concentrations of alpha-tocopherol in gel form on fracture strength, hybrid layer formation, and microtensile bond strength of endodontically treated teeth bleached with 40% hydrogen peroxide (H2 O2 ). Sixty bovine incisors were randomized into one of six groups (n = 10 incisors per group) defined by the interventions carried out after endodontic treatment. In the control group, no additional intervention was carried out, while all teeth in the five intervention groups were bleached with 40% H2 O2 and subsequently treated with alpha-tocopherol at concentrations of 15% (15AT), 20% (20AT), or 25% (25AT), with 10% sodium ascorbate (10SA), or with nothing (40HP). Fracture strength was evaluated in a mechanical testing machine, hybrid layer formation was assessed using scanning electron microscopy, and bond strength was determined using microtensile bond-strength testing. Data were analyzed using Kruskal-Wallis and Dunn's tests. No statistically significant difference regarding fracture strength was observed among groups. Hybrid layer formation was greater in the 15AT group than in groups 40HP and 10SA. Teeth in groups 15AT, 20AT, and 25AT demonstrated higher bond strength than teeth in groups 40HP and 10SA. Alpha-tocopherol, preferably at 15%, effectively reverses the deleterious effects, of bleaching, on hybrid layer formation and bond strength to dentin.
Collapse
Affiliation(s)
- Natália Marcomini
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, Araraquara, São Paulo, Brazil
| | - Maria Carolina da Costa Albaricci
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, Araraquara, São Paulo, Brazil
| | - Joatan Lucas de Sousa Gomes Costa
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, Araraquara, São Paulo, Brazil
- Department of Restorative Dentistry, School of Dentistry, Federal University of Minas Gerais - UFMG, Belo Horizonte, Minas Gerais, Brazil
| | - João Felipe Besegato
- School of Dentistry, Federal University of Mato Grosso do Sul - UFMS, Campo Grande, Mato Grosso do Sul, Brazil
| | | | - Andréa Abi Rached Dantas
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, Araraquara, São Paulo, Brazil
| | - Milton Carlos Kuga
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, Araraquara, São Paulo, Brazil
| |
Collapse
|
2
|
Brewster J, Roberts HW. 12-Month flexural mechanical properties of conventional and self-adhesive flowable resin composite materials. Dent Mater J 2023:2023-011. [PMID: 37302821 DOI: 10.4012/dmj.2023-011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
The aim of this study was to investigate the 12-month flexural mechanical properties of 23 flowable resin-based composites (FRBC) that included 5 self-adhesive FRBC materials. Specimens were evaluated following ISO 4049:2019 guidelines, but additionally stored in physiologic 0.2M phosphate buffered saline solution being tested at 24 h, 1 week, 1 month, and at 3-, 6-, 9-, and 12-months. While some deviation and degradation were noted at testing intervals, conventional FRBC materials overall demonstrated greater flexural strength than the self-adhesive and compomer materials. Three self-adhesive materials and the compomer were below recommended ISO 4049:2019 flexural strength values at 24 h with another after 6 months storage. Conventional FRBC materials, except at 1 month, overall demonstrated increased flexural modulus than the self-adhesive FRBC materials. Although results were material dependent, conventional FRBC materials demonstrated overall greater flexural mechanical properties as compared to the self-adhesive FRBC materials and the compomer evaluated.
Collapse
|
3
|
Orabi Kassab Bashi MA, Bshara N, Alzoubi H. Evaluation of Self-Adhesive Composite Restorations Bond on Primary Canines: An In Vitro Study. Cureus 2023; 15:e35005. [PMID: 36938186 PMCID: PMC10020875 DOI: 10.7759/cureus.35005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/14/2023] [Indexed: 02/17/2023] Open
Abstract
Background and purpose The aesthetic requirements for the restoration of the primary anterior teeth of both the child and his parents increased recently, especially with the presence of materials with good mechanical properties capable of giving a good aesthetic shape. However, the challenge remains in the possibility of applying these materials to primary teeth, where the child's cooperation and ability to keep their mouth open during the completion of the restoration is an important challenge for the dentist. Therefore, this study aimed to evaluate the bonding of self-adhesive composite by studying the microleakage in primary canines. Materials and methods The studied sample consisted of 60 extracted primary canines that were divided into three equal groups (n=20) according to the type of restoration: group 1 (experimental) - self-adhesive composite alone, group 2 (experimental) - self-adhesive composite with selective enamel etching, and group 3 (control) - conventional composite with the self-etching bond and selective enamel etching. A Class V cavity was prepared at the cementoenamel junction, 2 mm deep and 1 mm in diameter. In this way, the gingival wall is dentine, while the incisal wall is enamel-dentine. Restorations were placed according to the group to which the tooth belongs. After that, all teeth were subjected to 500 cycles of thermocycling. Then, a methylene blue dye microleakage test was performed, and longitudinal sections of the teeth were made and studied under x20 magnification using a stereo microscope. Results In the gingival wall, the scores of microleakage in the conventional composite group after selective etching were lower than those of the self-adhesive composite groups, with a statistically significant difference. While in the incisal wall, there were no statistically significant differences in the frequencies of the scores of microleakage between the three groups. Conclusions Within the limitations of this study, the conventional composite bonded better to enamel and dentine than self-adhesive composite resin applied alone or after selective enamel etching. The bonding of the self-adhesive composite was lower than that of the conventional composite, and it is not recommended to use it in Class V restorations of primary anterior teeth.
Collapse
Affiliation(s)
| | - Nada Bshara
- Department of Pediatric Dentistry, Damascus University, Damascus, SYR
| | - Hasan Alzoubi
- Department of Pediatric Dentistry, Damascus University, Damascus, SYR
| |
Collapse
|
4
|
Kaptan A, Oznurhan F. Effects of Er:YAG and Er,Cr:YSGG laser irradiation and adhesive systems on microtensile bond strength of a self-adhering composite. Lasers Med Sci 2023; 38:41. [PMID: 36652020 DOI: 10.1007/s10103-022-03663-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2021] [Accepted: 12/08/2022] [Indexed: 01/19/2023]
Abstract
This study was aimed to evaluate the effects of Er:YAG and Er,Cr:YSGG laser irradiation and adhesive systems on the microtensile bond strength of Fusio Liquid Dentin (FLD) which is a self-adhering composite (SAC). Twenty-four freshly extracted human molar teeth were collected, and the enamel was removed from the occlusal surface to obtain a flat dentin surface. Twenty-four teeth were randomly divided into eight groups: Group 1: only Fusio Liquid Dentin (FLD) (Petron Clinical, Orange, California, USA) was applied to the dentin surface; Group 2: 37% Phosphoricacid (i-GEL, Medicinos Linija UAB, Lithuania) + FLD; Group 3: Single Bond Universal (SBU) (3 M ESPE, Germany) + FLD; Group 4: Adper Easy One (AEO) (3 M ESPE, Germany) + FLD; Group 5: Er:YAG laser + AEO + FLD; Group 6: Er:YAG laser + SBU + FLD; Group 7: Er,Cr:YSGG laser + AEO + FLD; and Group 8: Er,Cr:YSGG laser + SBU + FLD. After thermocycling, 1 × 1 mm2 sticks were used for the µTBS test (n = 10). Two sticks per group were used for SEM analysis. Fractured sample surfaces were evaluated using a stereomicroscope. Group 8 showed the highest µTBS value (13.70 MPa), whereas Group 1 showed the lowest μTBS value (5.60 MPa). There were no significant differences between Groups 2, 3, and 4 (P = 0.324), but Groups 5-8 showed statistically significant results that were higher than Groups 1-4 (P = 0.012). Adhesive failure mode was predominant followed by mixed failure. The evaluation of bonding of the FLD to dentin showed that the combined use of Er:YAG and Er,Cr:YSGG lasers with SBU and AEO on dentin surfaces improved the dentinal bond strength of the FLD.
Collapse
Affiliation(s)
- Alper Kaptan
- Faculty of Dentistry Department of Restorative Dentistry, Sivas Cumhuriyet University, Kampüs-Merkez, Sivas, Turkey
| | - Fatih Oznurhan
- Faculty of Dentistry Department of Pediatric Dentistry, Sivas Cumhuriyet University, Kampüs-Merkez, Sivas, Turkey.
| |
Collapse
|
5
|
Alsunbul H, Alfawaz YF, Alhamdan EM, Farooq I, Vohra F, Abduljabbar T. Influence of carbon and graphene oxide nanoparticle on the adhesive properties of dentin bonding polymer: A SEM, EDX, FTIR study. J Appl Biomater Funct Mater 2023; 21:22808000231159238. [PMID: 36905128 DOI: 10.1177/22808000231159238] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/12/2023] Open
Abstract
OBJECTIVE This study was aimed at including 2.5 wt.% of carbon nanoparticles (CNPs) and graphene oxide NPs (GNPs) in a control adhesive (CA) and then investigate the effect of this inclusion on their mechanical properties and its adhesion to root dentin. MATERIALS AND METHODS Scanning electron microscopy and energy dispersive X-ray (SEM-EDX) mapping were conducted to investigate the structural features and elemental distribution of CNPs and GNPs, respectively. These NPs were further characterized by Raman spectroscopy. The adhesives were characterized by evaluating their push-out bond strength (PBS), rheological properties, degree of conversion (DC) investigation, and failure type analysis. RESULTS The SEM micrographs revealed that the CNPs were irregular and hexagonal, whereas the GNPs were flake-shaped. EDX analysis showed that carbon (C), oxygen (O), and zirconia (Zr) were found in the CNPs, while the GNPs were composed of C and O. The Raman spectra for CNPs and GNPs revealed their characteristic bands (CNPs-D band: 1334 cm-1, GNPs-D band: 1341 cm-1, CNPs-G band: 1650 cm-1, and GNPs-G band: 1607 cm-1). The testing verified that the highest bond strength to root dentin were detected for GNP-reinforced adhesive (33.20 ± 3.55 MPa), trailed closely by CNP-reinforced adhesive (30.48 ± 3.10 MPa), while, the CA displayed lowest values (25.11 ± 3.60 MPa). The inter-group comparisons of the NP-reinforced adhesives with the CA revealed statistically significant results (p < 0.01). Failures of adhesive nature were most common in within the adhesives and root dentin. The rheological assessment results demonstrated a reduced viscosity for all the adhesives observed at advanced angular frequencies. All the adhesives verified suitable dentin interaction shown by hybrid layer and appropriate resin tag development. A reduced DC was perceived for both NP-reinforced adhesives, compared to the CA. CONCLUSION The present study's findings have demonstrated that 2.5% GNP adhesive revealed the highest, suitable root dentin interaction, and acceptable rheological properties. Nevertheless, a reduced DC was observed (matched with the CA). Prospective studies probing the influence of diverse concentrations of filler NPs on the adhesive's mechanical properties to root dentin are recommended.
Collapse
Affiliation(s)
- Hanan Alsunbul
- Department of Restorative Dentistry, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Yasser F Alfawaz
- Department of Restorative Dentistry, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Eman M Alhamdan
- Prosthetic Dental Science Department, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Imran Farooq
- Faculty of Dentistry, University of Toronto, Toronto, ON, Canada
| | - Fahim Vohra
- Prosthetic Dental Science Department, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Tariq Abduljabbar
- Prosthetic Dental Science Department, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
6
|
Marigo L, Triestino A, Castagnola R, Vincenzoni F, Cordaro M, Di Stasio E, Mordente A, Nocca G. Cytotoxic Evaluation of the New Composite Resin through an Artificial Pulp Chamber. BIOMED RESEARCH INTERNATIONAL 2022; 2022:5100816. [PMID: 36440368 PMCID: PMC9683947 DOI: 10.1155/2022/5100816] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Revised: 11/02/2022] [Accepted: 11/07/2022] [Indexed: 11/27/2023]
Abstract
The aim of this study was to analyse the cytocompatibility of Surefil One (SuO) with respect to the release of monomers from the material. The following reference materials were chosen: SDR Flow Plus (SDR, Dentsply Sirona, Konstanz, Germany), One Q Bond (Q, Dentalica, Milan, Italy), and Ketac (K, 3M-ESPE, USA). Fifteen dentin discs (2 mm thickness and diameter) were obtained from 15 third molars and were used in this study. After dentin disc permeability measurement, murine fibroblasts were grown, and the pulp surface of the dentinal disc was placed in direct contact with the cells immersed in DMEM. The experimental materials were positioned on the occlusal side of each dentinal disc until a uniform thickness of 2 mm was obtained. Then, the discs were inserted into an artificial pulp chamber for 24 hours to assess the cytocompatibility. Afterwards, the moles of monomers leached from the specimens in DMEM were determined using HPLC. Statistical analysis was performed using ANOVA (p < 0.05). Under the experimental conditions, the toxic effect induced by all tested materials was slight or absent. Diurethane dimethacrylate and acrylic acid were not found in the culture media. It is concluded that all materials have good cytocompatibility consistent with the nondeterminability of the monomers released after polymerization.
Collapse
Affiliation(s)
- Luca Marigo
- UOC Odontoiatria Generale e Ortodonzia, Dipartimento Scienze dell'Invecchiamento, Neurologiche, Ortopediche e della Testa-Collo, Fondazione Policlinico Universitario A. Gemelli, IRCCS, Largo Agostino Gemelli 8, Rome 00168, Italy
- Dipartimento di Testa-Collo e Organi di Senso, Università Cattolica del Sacro Cuore, Largo Agostino Gemelli 8, Rome 00168, Italy
| | - Alessio Triestino
- UOC Odontoiatria Generale e Ortodonzia, Dipartimento Scienze dell'Invecchiamento, Neurologiche, Ortopediche e della Testa-Collo, Fondazione Policlinico Universitario A. Gemelli, IRCCS, Largo Agostino Gemelli 8, Rome 00168, Italy
- Dipartimento di Testa-Collo e Organi di Senso, Università Cattolica del Sacro Cuore, Largo Agostino Gemelli 8, Rome 00168, Italy
| | - Raffaella Castagnola
- UOC Odontoiatria Generale e Ortodonzia, Dipartimento Scienze dell'Invecchiamento, Neurologiche, Ortopediche e della Testa-Collo, Fondazione Policlinico Universitario A. Gemelli, IRCCS, Largo Agostino Gemelli 8, Rome 00168, Italy
- Dipartimento di Testa-Collo e Organi di Senso, Università Cattolica del Sacro Cuore, Largo Agostino Gemelli 8, Rome 00168, Italy
| | - Federica Vincenzoni
- Dipartimento di Scienze Biotecnologiche di Base, Cliniche Intensivologiche e Perioperatorie, Sezione di Biochimica, Università Cattolica del Sacro Cuore, Largo F. Vito, 1, 00168 Rome, Italy
- Fondazione Policlinico Universitario A. Gemelli, IRCCS, Largo A. Gemelli 8, 00168 Rome, Italy
| | - Massimo Cordaro
- UOC Odontoiatria Generale e Ortodonzia, Dipartimento Scienze dell'Invecchiamento, Neurologiche, Ortopediche e della Testa-Collo, Fondazione Policlinico Universitario A. Gemelli, IRCCS, Largo Agostino Gemelli 8, Rome 00168, Italy
- Dipartimento di Testa-Collo e Organi di Senso, Università Cattolica del Sacro Cuore, Largo Agostino Gemelli 8, Rome 00168, Italy
| | - Enrico Di Stasio
- Dipartimento di Scienze Biotecnologiche di Base, Cliniche Intensivologiche e Perioperatorie, Sezione di Biochimica, Università Cattolica del Sacro Cuore, Largo F. Vito, 1, 00168 Rome, Italy
- Fondazione Policlinico Universitario A. Gemelli, IRCCS, Largo A. Gemelli 8, 00168 Rome, Italy
| | - Alvaro Mordente
- Dipartimento di Scienze Biotecnologiche di Base, Cliniche Intensivologiche e Perioperatorie, Sezione di Biochimica, Università Cattolica del Sacro Cuore, Largo F. Vito, 1, 00168 Rome, Italy
- Fondazione Policlinico Universitario A. Gemelli, IRCCS, Largo A. Gemelli 8, 00168 Rome, Italy
| | - Giuseppina Nocca
- Dipartimento di Scienze Biotecnologiche di Base, Cliniche Intensivologiche e Perioperatorie, Sezione di Biochimica, Università Cattolica del Sacro Cuore, Largo F. Vito, 1, 00168 Rome, Italy
- Fondazione Policlinico Universitario A. Gemelli, IRCCS, Largo A. Gemelli 8, 00168 Rome, Italy
| |
Collapse
|
7
|
Sadeghyar A, Lettner S, Watts DC, Schedle A. Alternatives to amalgam: Is pretreatment necessary for effective bonding to dentin? Dent Mater 2022; 38:1703-1709. [PMID: 36115700 DOI: 10.1016/j.dental.2022.08.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Revised: 08/29/2022] [Accepted: 08/29/2022] [Indexed: 11/29/2022]
Abstract
OBJECTIVE The aim of this study was to determine whether pretreatment of the dentin surface is beneficial or not by analysis of the bond strengths of four self-adhesive restoratives and four restoration materials where pretreatment of dentin was necessary. METHODS Bovine incisors (n = 160) were ground flat on the labial surfaces to expose dentin using a grinder and silicon carbide (SiC) abrasive papers under running water. Between preparation and bonding procedures, the crowns were stored in Chloramine-T solution at 4 °C. Eight different restorative materials were studied: Activa BioActive (ABA), Cention Forte (CNF), Ceram.x Spectra ST (CXS), Riva self-cure (RSC), Equia Forte (EQF), Fuji II LC (FJI), Ketac Molar (KTM), Surefil one (SFO). Four materials required pretreatment of the dental hard tissue before placement, whereas the other four were self-adhesive (no pretreatment). The specimens were mounted vertically in plaster. A preload of 5 N was applied and the subsequent cross-head speed was 0.8 mm/min. Shear bond strengths (MPa) were calculated as the failure load divided by the bonding area. Failure modes were recorded as adhesive, cohesive or pretest. Data were statistically analyzed via ordinal regression for inference and Tukey's method to adjust for multiple comparisons. All computations were done using R version 4.1.2 (R Core Team 2021). RESULTS Smax (failure stress in MPa) of the combined groups with pretreatment were significantly higher than the self-adhesive materials. The highest frequency of pretest-failure was seen with FJI. Glass-ionomer cements without pretreatment were the only restoratives with pretest failures. Amongst materials without pretreatment, SFO had the highest bond strengths. SIGNIFICANCE The further reduction of the placement steps for materials used as an amalgam alternative, namely the omission of pretreatment of the dentin, results in these self-adhesive materials having lower bond strengths than materials that require pretreatment of the dentin.
Collapse
Affiliation(s)
- A Sadeghyar
- University Clinic of Dentistry, Medical University of Vienna, Austria
| | - S Lettner
- University Clinic of Dentistry, Medical University of Vienna, Austria
| | - D C Watts
- School of Medical Sciences and Photon Science Institute, University of Manchester, Manchester, UK
| | - A Schedle
- University Clinic of Dentistry, Medical University of Vienna, Austria.
| |
Collapse
|
8
|
Shear Bond Strength of Self-Adhesive Flowable Resin Composite. Int J Dent 2022; 2022:6280624. [PMID: 35572356 PMCID: PMC9106484 DOI: 10.1155/2022/6280624] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2022] [Revised: 03/21/2022] [Accepted: 03/30/2022] [Indexed: 11/18/2022] Open
Abstract
This study aimed to evaluate the shear bond strength of self-adhesive flowable resin composite on both enamel and dentin and investigate whether surface pretreatment with a phosphoric acid etch affects the bond strength. In this in vitro study, 80 sound human premolars were flattened to create (40) uniform enamel (E) and (40) dentin (D) surfaces. Groups were divided according to surface pretreatment: E1 : Scotchbond™ Universal Etchant + Single Bond Universal Adhesive + Filtek™ Z350 XT flowable composite; E2: Single Bond Universal self-etch adhesive + Filtek Z350 XT flowable composite; E3 : Scotchbond Universal Etchant + Fusio Liquid Dentin self-adhesive flowable composite; E4: Fusio Liquid Dentin self-adhesive flowable composite; D1 : Scotchbond Universal Etchant + Single Bond Universal Adhesive + Filtek Z350 XT flowable composite; D2: Single Bond Universal self-etch adhesive + Filtek Z350 XT flowable composite; D3: Scotchbond Universal Etchant + Fusio Liquid Dentin self-adhesive flowable composite; D4: Fusio Liquid Dentin self-adhesive flowable composite. After 2500 thermal cycles, the SBS was measured with a universal testing machine. One-way analysis of variance and Tukey's test for multiple comparisons were used to compare results. Two-way ANOVA was done to observe the significance of interaction between the type of surface and treatment. The maximum (49.38 ± 1.23 MPa) and minimum (21.41 ± 5.27 MPa) SBS values were noted in groups D1 and E2, respectively. Shear bond test results showed that self-adhesive flowable composite exhibited similar shear bond strengths on enamel and dentin and the bond strength improved with selective acid etching.
Collapse
|
9
|
Evaluation of Microleakage of Self-Adhesive Composite Resin in Pits and Fissures of Extracted Premolar Teeth: An in Vitro Study. JORJANI BIOMEDICINE JOURNAL 2022. [DOI: 10.52547/jorjanibiomedj.10.2.62] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/17/2023]
|
10
|
Kamatchi M, Ajay R, Gawthaman M, Maheshmathian V, Preethi K, Gayatrikumary T. Tensile Bond Strength and Marginal Integrity of a Self-adhering and a Self-etch Adhesive Flowable Composite after Artificial Thermomechanical Aging. Int J Clin Pediatr Dent 2022; 15:204-209. [PMID: 37457209 PMCID: PMC10338951 DOI: 10.5005/jp-journals-10005-2370] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2023] Open
Abstract
Aim This study aims to compare the self-etch adhesive (SEA) and self-adhesive flowable composite (SAF) concerning tensile bond strength (TBS) and marginal integrity by microleakage (µ LK) test in deciduous molars after artificial thermomechanical aging. Materials and methods 120 extracted primary molars were collected. Sixty teeth were mounted for testing TBS. Teeth were restored using SAF (n = 30) and SEA-conventional flowable (CF) composite (n = 30) and subjected to artificial thermal aging. Half the teeth (n = 15) from each material were subjected to mechanical loading (SEA-TBS-L and SAF-TBS-L). The specimens with no-load (NL) served as control (SEA-TBS-NL and SAF-TBS-NL). Class V cavity prepared and restored with SAF (n = 30) and SEA-CF (n = 30) to test µ LK after thermal aging. The subgroups were as same as the TBS based on with or without mechanical loading (SEA-µ LK-L, SEA-µ LK-NL, SAF-µ LK-L, SAF-µ LK-L; n = 15 each). µ LK was determined by employing the dye immersion technique. Results Concerning TBS, there is a significant difference between SEA and SAF with load or no load. Concerning µ LK, there is a significant difference between the materials under loading and no difference was found when not mechanically loaded. Also, concerning both TBS and µ LK, a significant difference was observed between the load and no-load subgroups within each material. Conclusion SAF exhibited higher TBS than the SEA. Mechanical loading not only adversely affected the TBS but also increased the µLK of the compared materials. Clinical Significance Restoring the primary teeth with SAF not only shortens the laborious operatory time but also yields good clinical serviceability with the good bond strength and minimal µ LK, thus preventing premature loss of teeth and consequential malocclusion. How to cite this article Kamatchi M, Ajay R, Gawthaman M, et al. Tensile Bond Strength and Marginal Integrity of a Self-adhering and a Self-etch Adhesive Flowable Composite after Artificial Thermomechanical Aging. Int J Clin Pediatr Dent 2022;15(2):204-209.
Collapse
Affiliation(s)
- Mohanraj Kamatchi
- Department of Pedodontics and Preventive Dentistry, Vivekanandha Dental College for Women, Tiruchengode, Tamil Nadu, India
| | - Ranganathan Ajay
- Department of Prosthodontics and Crown and Bridge, Vivekanandha Dental College for Women, Tiruchengode, Tamil Nadu, India
| | - Murugesan Gawthaman
- Department of Pedodontics and Preventive Dentistry, Vivekanandha Dental College for Women, Tiruchengode, Tamil Nadu, India
| | - Veerabadhran Maheshmathian
- Department of Pedodontics and Preventive Dentistry, Vivekanandha Dental College for Women, Tiruchengode, Tamil Nadu, India
| | - Kumaragurubaran Preethi
- Department of Orthodontics and Dentofacial Orthopedics, Vivekanandha Dental College for Women, Tiruchengode, Tamil Nadu, India
| | - Thiyagarajan Gayatrikumary
- Department of Pedodontics and Preventive Dentistry, Vivekanandha Dental College for Women, Tiruchengode, Tamil Nadu, India
| |
Collapse
|
11
|
Iaculli F, Salucci A, Di Giorgio G, Luzzi V, Ierardo G, Polimeni A, Bossù M. Bond Strength of Self-Adhesive Flowable Composites and Glass Ionomer Cements to Primary Teeth: A Systematic Review and Meta-Analysis of In Vitro Studies. MATERIALS 2021; 14:ma14216694. [PMID: 34772221 PMCID: PMC8586968 DOI: 10.3390/ma14216694] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/07/2021] [Revised: 10/25/2021] [Accepted: 11/04/2021] [Indexed: 11/17/2022]
Abstract
Background: Conventional composites are largely used in pediatric restorative dentistry and demonstrate successful clinical outcomes. However, the need for simplification of operative steps in young or uncooperative children demands reliable alternatives. Therefore, the aim of the present systematic review and meta-analysis was to evaluate the in vitro bond strength of glass ionomer cements (GICs) and self-adhesive flowable composites (SFCs) on deciduous teeth. Methods: A comprehensive literature search according to the PRISMA checklist was manually and electronically performed by two independent reviewers through the following databases: MEDLINE/PubMed, Google Scholar, Scopus, and Embase, to include in vitro studies comparing GICs and SFCs bond strength values of restorations on primary teeth. In addition, three groups of meta-analyses were conducted using random-effects models. Results: Three articles meeting the inclusion criteria were selected and subjected to both qualitative and quantitative assessment. No statistically significant difference was found between SFC versus GIC; however, both groups significantly differed with conventional flowable composites (CFs). Conclusions: Despite the absence of significant difference in bond strength values, SFCs may be considered a valid alternative to GICs in the restoration of deciduous teeth, although CFs proved better in vitro performances.
Collapse
Affiliation(s)
- Flavia Iaculli
- Department of Neuroscience and Reproductive and Odontostomatological Sciences, University of Naples Federico II, 80131 Naples, Italy;
- Department of Oral and Maxillofacial Science, “Sapienza” University of Rome, 00161 Rome, Italy; (A.S.); (V.L.); (G.I.); (A.P.); (M.B.)
| | - Alessandro Salucci
- Department of Oral and Maxillofacial Science, “Sapienza” University of Rome, 00161 Rome, Italy; (A.S.); (V.L.); (G.I.); (A.P.); (M.B.)
| | - Gianni Di Giorgio
- Department of Oral and Maxillofacial Science, “Sapienza” University of Rome, 00161 Rome, Italy; (A.S.); (V.L.); (G.I.); (A.P.); (M.B.)
- Correspondence:
| | - Valeria Luzzi
- Department of Oral and Maxillofacial Science, “Sapienza” University of Rome, 00161 Rome, Italy; (A.S.); (V.L.); (G.I.); (A.P.); (M.B.)
| | - Gaetano Ierardo
- Department of Oral and Maxillofacial Science, “Sapienza” University of Rome, 00161 Rome, Italy; (A.S.); (V.L.); (G.I.); (A.P.); (M.B.)
| | - Antonella Polimeni
- Department of Oral and Maxillofacial Science, “Sapienza” University of Rome, 00161 Rome, Italy; (A.S.); (V.L.); (G.I.); (A.P.); (M.B.)
| | - Maurizio Bossù
- Department of Oral and Maxillofacial Science, “Sapienza” University of Rome, 00161 Rome, Italy; (A.S.); (V.L.); (G.I.); (A.P.); (M.B.)
| |
Collapse
|
12
|
de Oliveira NG, da Silveira MT, da Silva LP, Barros KMA, Costa LM, Soares MDL, Carvalho MDV. Morphological analysis and immunohistochemical expression in restorations with self-adhesive resin: A randomized split-mouth design-controlled study. J Clin Exp Dent 2021; 13:e927-e934. [PMID: 34603622 PMCID: PMC8464382 DOI: 10.4317/jced.58413] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Accepted: 05/24/2021] [Indexed: 01/26/2023] Open
Abstract
Background To evaluate the morphology and immunohistochemical expression of MMP-9, TIMP-3, COL-I, TNF-alfa and COX-2 in the dentinopulp complex of restorations with self adhesive composite (Vertise Flow/Kerr) compared with conventional resin composite with self-etching adhesive (Filtek Z250/3M ESPE and Clearfil SE Bond/Kuraray-Noritake). Material and Methods A randomized, controlled, double-blind, split-mouth, two-arm clinical trial was conducted. Twenty-seven volunteers with third molars indicated for extraction received two deep class I restorations, one with each material. The morphology and immunohistochemical expression were measured at 15 days after the restorative procesures. The data were submitted to the Fisher`s Exct test (α=0.05). Results Through morphological analysis, a slight disorganization of the odontoblastic layer was visualized, along with a slight inflammatory infiltrate in the VERT and CSEB groups (p< 0.05). In immunohistochemical analysis, TNF-alpha, MMP-9, TIMP-3 and COX-2 demonstrated more cases of positive pulp labeling. Conclusions Self-adhesive resin composite and conventional resin composite with a self-etching bonding agent promoted slight alterations in the dentin-pulp complex, indicating a repair ability and reversibility of the inflammatory process against aggressions of the adhesive restorative procedure. Key words:Immunohistochemistry, inflammation, randomized clinical trial, self-adhering composite, dentistry.
Collapse
Affiliation(s)
| | | | - Leorik-Pereira da Silva
- MSc, PhD, Adjunct Professor, Dental School, Universidade Federal de Campina Grande (UFCG), PB, Brazil
| | | | - Laís-Maciel Costa
- MSc, PhD student, Dental School, Universidade de Pernambuco/FOP-UPE; Camaragibe, PE, Brazil
| | | | | |
Collapse
|
13
|
Bond strength of self-adhesive flowable composite resins to dental tissues: A systematic review and meta-analysis of in vitro studies. J Prosthet Dent 2021; 128:876-885. [PMID: 33838916 DOI: 10.1016/j.prosdent.2021.02.020] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2020] [Revised: 02/17/2021] [Accepted: 02/17/2021] [Indexed: 11/24/2022]
Abstract
STATEMENT OF PROBLEM Although the clinical use of self-adhesive flowable composite resins is convenient, the decision to use flowable or conventional composite resin remains controversial. PURPOSE The purpose of this systematic review and meta-analysis was to assess the in vitro bond strength of self-adhesive flowable composite resins to enamel or dentin compared with conventional composite resins using etch-and-rinse or self-etch adhesive systems. MATERIAL AND METHODS Two independent reviewers performed searches in the PubMed (MEDLINE), Cochrane Wiley, Web of Science, Scopus, and Google Scholar databases for studies reporting on the bond strength of self-adhesive flowable and conventional composite resins to enamel and dentin published from January 2010 up to September 2020. A meta-analysis software program was used for the meta-analysis. Comparisons were conducted using standardized mean differences considering the random-effects model (α=.05). RESULTS Twenty-two studies were considered for the meta-analysis. Immediate and long-term bond strength to enamel was improved when a conventional composite resin was used in combination with an adhesive system (P<.001). Bond strength to dentin was improved by using an adhesive system in combination with a conventional composite resin (P<.001). CONCLUSIONS The bond strength of self-adhesive flowable composite resins is lower than that of conventional composite resins, indicating limited ability to bond to enamel and dentin.
Collapse
|
14
|
Comparison between Shear Bond Strength of Er:YAG and Er,Cr:YSGG Lasers-Assisted Dentinal Adhesion of Self-Adhering Resin Composite: An Ex Vivo Study. Dent J (Basel) 2020; 8:dj8030066. [PMID: 32630313 PMCID: PMC7558720 DOI: 10.3390/dj8030066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Revised: 06/25/2020] [Accepted: 06/27/2020] [Indexed: 11/30/2022] Open
Abstract
(1) Background: Bonding composite to tooth structure is still evolving with a substitute for phosphoric acid being the main challenge. Lately, a self-adhering composite (SAC) was developed, promising to simplify bonding to tooth structure. Unfortunately, retention especially to dentin, was not as good as the gold standard three steps bonding system. During the last 2 decades, lasers were used to enhance shear bond strength of composite to tooth structure. However, the literature provided limited information regarding laser efficiency in the immediate, as well as the long term, adhesion success of SACs to dentin. The purpose of our study was to define the optimal irradiation conditions to improve the adhesion of self-adhering flowable resin composite to dentin exposed to Er:YAG and Er,Cr:YSGG laser irradiation. (2) Methods: Seventy-two freshly extracted human third molars, prepared to have flat dentinal surfaces, were randomly divided into three groups (n = 24) including a control group (Group 1) in which dentin was left without laser irradiation. The other two groups (Group 2 and 3) received standardized irradiation at a speed of 1 mm/second with Er:YAG (60 mJ; SSP mode = 50 μs; 10 Hz; fluency of 9.4 J/cm2; beam diameter: 0.9 mm; air 6 mL/min; and water 4 mL/min), and Er,Cr:YSGG: 1.5 W; fluency of 17.8 J/cm2; turbo handpiece with MX5 short insert; 20 Hz under air/water spray (65% air, 55% water). Self-adhering flowable resin was applied to dentin in all groups. Half of the specimens were stored in water for 24 h while the other half underwent 3000 thermal cycles. Later, all specimens received a shear bond strength test. Fracture observation was done first under a stereomicroscope then by using a scanning electron microscope. (3) Results: The mean values of shear bond strength for both laser-treated dentin groups (Er:YAG laser: 13.10 ± 1.291, and Er,Cr:YSGG: 14.04 ± 5.233) were higher than in the control group 1 (8.355 ± 2.297) before thermocycling. After thermocycling, shear bond strength decreased in all groups as follows: 10.03 ± 1.503, 10.53 ± 2.631, and 02.75 ± 1.583 for Er:YAG, Er,Cr:YSGG, and nonirradiated dentin, respectively. Shear bond strength values showed a significant difference between the control group (Group 1) and both lasers groups (Group 2 and 3). Statistical analysis of stereomicroscope observation revealed no significant difference between laser irradiation and failure mode (p < 0.136). SEM observation of the dentin surface in both laser-irradiated groups showed opened tubules, absence of smear layer as well as an increase of resin infiltration into dentinal tubules. (4) Conclusion: Er:YAG and Er,Cr:YSGG lasers enhance self-adhering flowable resin shear bond strength values and improve its longevity by eliminating the smear layer, opening dentinal tubules and increasing resin infiltration into the microstructure.
Collapse
|
15
|
Zarabian T, Azadi Mood S, Kiomarsi N, Noorollahian H, Hakimiha N. Microshear Bond Strength of a Self-adhesive Composite to Erbium Laser-Treated Primary Enamel. J Lasers Med Sci 2020; 11:181-186. [PMID: 32273960 DOI: 10.34172/jlms.2020.30] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Introduction: Advances have been made in the composition of flowable composites in recent years and self-adhering composites, which do not require a bonding agent, have recently been introduced to the market. This study aimed to assess the microshear bond strength (µSBS) of a self-adhering flowable composite (Vertise) to primary enamel treated with a graphite disc with silicon carbide particles (SIC) and laser irradiation, the result of which was compared to that of a conventional flowable composite (Premise). Methods: In this in vitro, experimental study, 72 samples of sound primary enamel were evaluated. A smooth enamel surface was obtained using a graphite disc. Next, the erbium chromium yttrium scandium gallium garnet (Er,Cr:YSGG) laser was used for enamel surface treatment in half of the samples (n=36). All the samples were then randomly divided into 4 groups of (i) Premise flowable composite (PF) without laser (n=18), (ii) Vertise flowable composite (VF) without laser (n=18), (iii) PF with laser (n=18), and (iv) VF with laser (n=18). The teeth were then incubated at 37°C for 24 hours and were then subjected to thermocycling. The µSBS of samples was measured using a universal testing machine and reported in megapascal (MPa). Data were analyzed using SPSS via the two-way ANOVA and independent-samples t test at P<0.05. Results: The mean µSBS of VF was significantly higher to the laser-treated samples (13.60±5.47) compared with the non-treated samples (5.89±2.42) (P<0.001). However, no significant difference was noted in the µSBS of PF to the laser-treated (13.18±3.45) and non-treated samples (16.06±3.52) (P=0.058). Conclusion: The µSBS of the conventional flowable composite is higher than that of the self-adhering flowable composite to the enamel of primary teeth. Enamel surface treatment with laser irradiation increases the µSBS of self-adhering flowable composites.
Collapse
Affiliation(s)
- Tara Zarabian
- Department of Pediatric Dentistry, Dental Faculty, Tehran University of Medical Sciences, International Campus, Tehran, Iran
| | - Saba Azadi Mood
- Dentist, Tehran University of Medical Sciences, Tehran, Iran
| | - Nazanin Kiomarsi
- Department of Operative Dentistry, Dental Faculty, Tehran University of Medical Sciences, International Campus, Tehran, Iran
| | - Homa Noorollahian
- Department of Pediatric Dentistry, Dental Faculty, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Neda Hakimiha
- Laser Research Center of Dentistry, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
16
|
Serin BA, Yazicioglu I, Deveci C, Dogan MC. Clinical evaluation of a self-adhering flowable composite as occlusal restorative material in primary molars: one-year results. Eur Oral Res 2019; 53:119-124. [PMID: 31579892 PMCID: PMC6761486 DOI: 10.26650/eor.20190025] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2019] [Revised: 05/03/2019] [Accepted: 06/27/2019] [Indexed: 02/01/2023] Open
Abstract
Purpose: The aim of this study was to evaluate and compare the 1 year clinical performances
of a self-adhering flowable composite and a commercially available self-etch
adhesive/composite system in occlusal restorations of primary second molars. Materials and methods: Thirty-one patients (10 male, 21 female) were recruited into the study. A total of 62
occlusal cavities were restored with either a universal composite or a self-adhering
flowable composite according to manufacturers' instructions. The restorations were
clinically evaluated 1 month after placement as baseline, and after 3, 6 months and
1 year post-operatively using modified USPHS criteria by two operators. Results: Lack of retention was not observed in any of the restorations. With respect to color
match, marginal adaptation, secondary caries and surface texture, no significant
differences were found between two restorative materials tested after 1 year. None
of the restorations had marginal discoloration and anatomic form loss on the 1 year
follow-up. Restorations did not exhibit post-operative sensitivity at any evaluation
period. Conclusion: The clinical assessment of self-adhering flowable composite exhibited good clinical
results with predominating alpha scores after 1 year. Advantage of the application
convenience for children is promising for self-adhered flowable composite materials
in pediatric use.
Collapse
Affiliation(s)
- Buse Ayse Serin
- Department of Pediatric Dentistry, Faculty of Dentistry, Cukurova University, Adana, Turkey
| | - Iffet Yazicioglu
- Department of Pediatric Dentistry, Faculty of Dentistry, Cukurova University, Adana, Turkey
| | - Ceren Deveci
- Department of Pediatric Dentistry, Faculty of Dentistry, Cukurova University, Adana, Turkey
| | - Muharrem Cem Dogan
- Department of Pediatric Dentistry, Faculty of Dentistry, Cukurova University, Adana, Turkey
| |
Collapse
|
17
|
Poorzandpoush K, Shahrabi M, Heidari A, Hosseinipour ZS. Shear Bond Strength of Self-Adhesive Flowable Composite, Conventional Flowable Composite and Resin-Modified Glass Ionomer Cement to Primary Dentin. Front Dent 2019; 16:62-68. [PMID: 31608338 PMCID: PMC6778611 DOI: 10.18502/fid.v16i1.1111] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2018] [Accepted: 08/04/2018] [Indexed: 11/24/2022] Open
Abstract
Objectives: This study aimed to compare the shear bond strength (SBS) of self-adhesive and conventional flowable composites and resin-modified glass-ionomer cement (RMGIC) to primary dentin. Materials and Methods: In this in vitro, experimental study, the buccal surface of 48 primary canine and first molar teeth was longitudinally sectioned to expose dentin. The teeth were randomly divided into three groups (n=16) of 37.5% phosphoric acid+ OptiBond+ Premise Flow composite (group 1), Vertise Flow composite (group 2) and RMGIC (group 3). A plastic cylindrical mold was placed on the exposed dentin and filled with restorative materials. The samples were then immersed in distilled water at 37°C for 24 hours, subjected to 1000 thermal cycles between 5–55°C and underwent SBS test. The mode of failure was determined under a stereomicroscope. Data were analyzed using one-way ANOVA and Tukey’s test. Results: A significant difference was noted in SBS of the groups (P<0.05). The SBS of conventional flowable composite was significantly higher that of RMGIC and self-adhesive flowable composite (P<0.05). The difference in SBS of RMGIC and self-adhesive flowable composite was not significant (P>0.05). Failure at the dentin-restoration interface (adhesive failure) had the highest frequency in groups 1 and 2. The frequency of adhesive failure was 100% in group 3. Conclusion: Within the limitations of this study, the conventional flowable composite yielded the highest SBS to primary dentin. Self-adhesive flowable composite and RMGIC showed the lowest SBS with no significant difference with each other.
Collapse
Affiliation(s)
- Kiana Poorzandpoush
- Department of Pediatric Dentistry, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| | - Mehdi Shahrabi
- Department of Pediatric Dentistry, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.,Dental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran
| | - Alireza Heidari
- Department of Pediatric Dentistry, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| | - Zohre Sadat Hosseinipour
- Department of Pediatric Dentistry, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
18
|
Serin BA, Dogan MC, Yoldas HO. Comparison of the Shear Bond Strength of Silorane-Based Composite Resin and Methacrylate Based Composite Resin to MTA. J Dent Res Dent Clin Dent Prospects 2018; 12:1-5. [PMID: 29732014 PMCID: PMC5928468 DOI: 10.15171/joddd.2018.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2017] [Accepted: 01/07/2018] [Indexed: 11/16/2022] Open
Abstract
Background. Mineral trioxide aggregate (MTA) is a material that has recently gained popularity in the application of the vital pulp therapy. Along with the increasing use of MTA to this end, the permanent restoration material to be placed on MTA has become a significant issue. The aim of this in vitro study was to investigate the bond strength of the novel low-shrinkage silorane-based composite resin (SBC) to MTA.
Methods. Twenty acrylic blocks filled with MTA were prepared for this study. SBC was the test group and methacrylate-based composite resin (MBC) was used as the control group. Shear bond strength test was performed to determine the bond strength. The surfaces of broken samples were evaluated under a stereomicroscope and grouped as adhesive, cohesive and mixed. Data were examined by statistical analysis.
Results. Statistical analysis revealed that SBC exhibited higher shear bond strength than the control group. It was observed that most of the failures in the test group were of cohesive type within MTA.
Conclusion. Based on the results, SBC showed higher shear bond strength than the control group; however, clinical follow-up is needed to evaluate the clinical success.
Collapse
Affiliation(s)
- Buse Ayse Serin
- Department of pediatric dentistry, Faculty of Dentistry, University of Cukurova Adana-Turkey
| | - Muharrem Cem Dogan
- Department of Restorative dentistry, Faculty of Dentistry, University of Cukurova.Adana-Turkey
| | - Hamdi Oguz Yoldas
- Department of Endodontics, Faculty of Dentistry, Cukurova University, Adana, Turkey
| |
Collapse
|
19
|
Maas MS, Alania Y, Natale LC, Rodrigues MC, Watts DC, Braga RR. Trends in restorative composites research: what is in the future? Braz Oral Res 2017; 31:e55. [PMID: 28902235 DOI: 10.1590/1807-3107bor-2017.vol31.0055] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2017] [Accepted: 05/22/2017] [Indexed: 01/12/2023] Open
Abstract
Clinical trials have identified secondary caries and bulk fracture as the main causes for composite restoration failure. As a measure to avoid frequent reinterventions for restoration replacement, composites with some sort of defense mechanism against biofilm formation and demineralization, as well as materials with lower susceptibility to crack propagation are necessary. Also, the restorative procedure with composites are very time-consuming and technically demanding, particularly concerning the application of the adhesive system. Therefore, together with bulk-fill composites, self-adhesive restorative composites could reduce operator error and chairside time. This literature review describes the current stage of development of remineralizing, antibacterial and self-healing composites. Also, an overview of the research on fiber-reinforced composites and self-adhesive composites, both introduced for clinical use in recent years, is presented.
Collapse
Affiliation(s)
- Mariel Soeiro Maas
- Universidade de São Paulo - USP, School of Dentistry,Department of Biomaterials and Oral Biology, São Paulo, SP, Brazil
| | - Yvette Alania
- Universidade de São Paulo - USP, School of Dentistry,Department of Biomaterials and Oral Biology, São Paulo, SP, Brazil
| | - Livia Camargo Natale
- Universidade de São Paulo - USP, School of Dentistry,Department of Biomaterials and Oral Biology, São Paulo, SP, Brazil
| | - Marcela Charantola Rodrigues
- Universidade de São Paulo - USP, School of Dentistry,Department of Biomaterials and Oral Biology, São Paulo, SP, Brazil
| | - David Christopher Watts
- University of Manchester School of Medical Sciences, Division of Dentistry, Manchester, United Kingdom
| | - Roberto Ruggiero Braga
- Universidade de São Paulo - USP, School of Dentistry,Department of Biomaterials and Oral Biology, São Paulo, SP, Brazil
| |
Collapse
|
20
|
Poggio C, Beltrami R, Colombo M, Chiesa M, Scribante A. Influence of dentin pretreatment on bond strength of universal adhesives. ACTA BIOMATERIALIA ODONTOLOGICA SCANDINAVICA 2017. [PMID: 28642929 PMCID: PMC5463333 DOI: 10.1080/23337931.2017.1305273] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Objective: The purpose of the present study was to compare bond strength of different universal adhesives under three different testing conditions: when no pretreatment was applied, after 37% phosphoric acid etching and after glycine application. Materials and methods: One hundred and fifty bovine permanent mandibular incisors were used as a substitute for human teeth. Five different universal adhesives were tested: Futurabond M+, Scotchbond Universal, Clearfil Universal Bond, G-Premio BOND, Peak Universal Bond. The adhesive systems were applied following each manufacturer's instructions. The teeth were randomly assigned to three different dentin surface pretreatments: no pretreatment agent (control), 37% phosphoric acid etching, glycine pretreatment. The specimens were placed in a universal testing machine in order to measure and compare bond strength values. Results: The Kruskal-Wallis analysis of variance and the Mann-Whitney test were applied to assess significant differences among the groups. Dentin pretreatments provided different bond strength values for the adhesives tested, while similar values were registered in groups without dentin pretreatment. Conclusions: In the present report, dentin surface pretreatment did not provide significant differences in shear bond strength values of almost all groups. Acid pretreatment lowered bond strength values of Futurabond and Peak Universal Adhesives, whereas glycine pretreatment increased bond strength values of G Praemio Bond adhesive system.
Collapse
Affiliation(s)
- Claudio Poggio
- Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, Section of Dentistry, University of PaviaPaviaItaly
| | - Riccardo Beltrami
- Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, Section of Dentistry, University of PaviaPaviaItaly
| | - Marco Colombo
- Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, Section of Dentistry, University of PaviaPaviaItaly
| | - Marco Chiesa
- Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, Section of Dentistry, University of PaviaPaviaItaly
| | - Andrea Scribante
- Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, Section of Dentistry, University of PaviaPaviaItaly
| |
Collapse
|
21
|
Durmuşlar S, Ölmez A. Microtensile Bond Strength and Failure Modes of Flowable Composites on Primary Dentin with Application of Different Adhesive Strategies. Contemp Clin Dent 2017; 8:373-379. [PMID: 29042720 PMCID: PMC5643992 DOI: 10.4103/ccd.ccd_310_17] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Background: Resin composite is an option for the restoration of primary teeth, and new materials with simplified procedures are increasingly being suggested. Aims: This study aims to evaluate the microtensile bond strengths and fracture modes of flowable composites on primary dentin with application of different adhesive strategies. Materials and Methods: Sixty extracted noncaries primary molars were abraded from buccal surfaces to expose dentin surface. The teeth were randomly divided into three groups as follows: Group 1, Vertise™ Flow (Kerr) (self-adhering flowable composite); Group 2, G-aenial Universal Flo® (GC Europe) (used with one-step self-etch system); Group 3, Tetric® N-Flow (Ivoclar/Vivadent) (used with two-step total etch system). Then, the flowable composites were applied to buccal dentin surfaces with the help of guide mold. Samples were embedded in acrylic blocks and sectioned to form dentin-composite sticks with a surface area of approximately 1 mm2. Finally, a total of 180 sticks were obtained to give each group of 60 sticks. Microtensile bond strengths were measured using a universal testing machine (1 mm/min). Fracture modes were evaluated with scanning electron microscopy. Statistical Analysis: Microtensile bond strengths data were analyzed by Kruskal–Wallis nonparametric test. Results: The microtensile bond strengths of G-aenial (15.5 megapascals [Mpa]) and Tetric (13.0 MPa) were statistically significant higher than Vertise (2.3 MPa). It was recorded that most of fractures in G-aenial was 40% cohesive, Tetric was 53.3% mixed, and Vertise was 83.3% adhesive. Conclusions: The self-adhering flowable composite Vertise™ Flow had the lowest and G-aenial Universal Flo® had the highest microtensile bond values.
Collapse
Affiliation(s)
- Simge Durmuşlar
- Department of Pediatric Dentistry, Faculty of Dentistry, Bülent Ecevit University, Zonguldak, Turkey
| | - Ayşegül Ölmez
- Department of Pediatric Dentistry, Faculty of Dentistry, Gazi University, Ankara, Turkey
| |
Collapse
|