1
|
Yin Q, Mao D, Rui Y. [Experimental study on the causes of spontaneous osteogenesis of Masquelet technique induced membrane]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2024; 38:1254-1260. [PMID: 39433501 DOI: 10.7507/1002-1892.202403021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 10/23/2024]
Abstract
Objective To investigate the causes of spontaneous osteogenesis of Masquelet technique induced membrane. Methods Forty-two male Sprague-Dawley rats aged 7-9 weeks were selected to establish a critical-sized bone defect of the right middle femur model. Then the rats were randomly divided into 4 groups, with 12 rats in groups A-C and 6 rats in group D. The bone defects in groups A-C were filled with vancomycin-loaded polymethyl methacrylate bone cement spacers. Then the Kirschner wires were used for intramedullary fixation in groups A and B, and the bone cement was used to connect the bone cement spacers and the bone ends in group B. The steel plate was used to fixation in group C. The bone defect in group D was only fixed with steel plate as a blank control group. The general condition was observed after operation. At 5 weeks after operation, 6 rats in groups A-C were selected for STRO-1 immunohistochemical staining to observe the content of mesenchyme stem cells (MSCs) in the induced membrane (STRO-1 + cells). At 12 weeks after operation, the remaining rats in groups A-D were taken for X-ray observation, gross observation, and histological observation (HE, safranin O-green staining) to observe the spontaneous osteogenesis of the membrane. Results All rats in the 4 groups survived until the completion of the experiment. At 5 weeks after operation, the immunohistochemical staining showed that group B was negative, while the contents of MSCs in the induced membrane in groups A and C were 14.20%±1.92% and 5.00%±0.71%, respectively, with a significant difference ( P<0.05). At 12 weeks after operation, group A showed that the new bone formed at the osteotomy site and growth towards the center of the bone defect, with an average length of 3.1 mm on one side; and the presence of bone, cartilage lesions, fibers, and a small amount of neovascularization were observed in the induced membrane. Group C only had a small amount of new bone at the osteotomy site, and a small amount of neovascularization in the induced membrane. Groups B and D did not have any new bone, but bone resorption or atrophy at the osteotomy site. Conclusion Although the Masquelet technique induced membrane has osteogenesis, the key factor for the spontaneous osteogenesis is the bone marrow overflow from the bone marrow cavity providing MSCs. The spontaneous osteogenesis of the induced membrane belongs to endochondral ossification.
Collapse
Affiliation(s)
- Qudong Yin
- Department of Orthopaedics, Wuxi No.9 People's Hospital Affiliated to Soochow University, Wuxi Jiangsu, 214062, P. R. China
| | - Dong Mao
- Orthopedic Research Institute, Wuxi No.9 People's Hospital Affiliated to Soochow University, Wuxi Jiangsu, 214062, P. R. China
| | - Yongjun Rui
- Department of Orthopaedics, Wuxi No.9 People's Hospital Affiliated to Soochow University, Wuxi Jiangsu, 214062, P. R. China
| |
Collapse
|
2
|
Chen L, Han J, Guo C. Research status and prospects of biodegradable magnesium-based metal guided bone regeneration membranes. HUA XI KOU QIANG YI XUE ZA ZHI = HUAXI KOUQIANG YIXUE ZAZHI = WEST CHINA JOURNAL OF STOMATOLOGY 2024; 42:415-425. [PMID: 39049628 PMCID: PMC11338478 DOI: 10.7518/hxkq.2024.2024140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 04/11/2024] [Revised: 05/16/2024] [Indexed: 07/27/2024]
Abstract
Biodegradable magnesium-based metal guided bone regeneration (GBR) membranes possess excellent mechanical properties, biodegradability, and osteopromotive capabilities, making them ideal implants for the treatment of maxillofacial bone defects. This review summarizes the current status and future research trends related to magnesium-based GBR membranes. First, the research history and application fields of magnesium-based metals are introduced, and the advantages of the use of magnesium-based materials for GBR membranes, including their mechanical properties, biocompatibility, osteopromotive performance, and underlying mechanisms are discussed. Finally, this review addresses the current limitations of magnesium-based GBR membranes and their applications and prospects in the field of dentistry. In conclusion, considerable advancements have been in fundamental and translational research on magnesium-based GBR membranes, which lays a crucial foundation for the treatment of maxillofacial bone defects.
Collapse
Affiliation(s)
- Liangwei Chen
- Dept. of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology, Beijing 100081, China
- National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing 100081, China
| | - Jianmin Han
- National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing 100081, China
- Dept. of Key Laboratory, Peking University School and Hospital of Stomatology, Beijing 100081, China
| | - Chuanbin Guo
- Dept. of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology, Beijing 100081, China
- National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing 100081, China
| |
Collapse
|
3
|
Kim YR, Yun EB, Ryu DI, Kim BH, Kim JS, Kim YS, Kang JH, Cho EH, Koh JT, Lim HP, Park C, Lee BN. The potential bone regeneration effects of leptin- and osteolectin-coated 3D-printed PCL scaffolds: an in vivostudy. Biomed Mater 2024; 19:045008. [PMID: 38688311 DOI: 10.1088/1748-605x/ad45d7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Accepted: 04/30/2024] [Indexed: 05/02/2024]
Abstract
This study investigated the effectiveness of bone regeneration upon the application of leptin and osteolectin to a three-dimensional (3D) printed poly(ϵ-caprolactone) (PCL) scaffold. A fused deposition modeling 3D bioprinter was used to fabricate scaffolds with a diameter of 4.5 mm, a height of 0.5 mm, and a pore size of 420-520 nm using PCL (molecular weight: 43 000). After amination of the scaffold surface for leptin and osteolectin adhesion, the experimental groups were divided into the PCL scaffold (control), the aminated PCL (PCL/Amine) scaffold, the leptin-coated PCL (PCL/Leptin) scaffold, and the osteolectin-coated PCL (PCL/Osteo) scaffold. Next, the water-soluble tetrazolium salt-1 (WST-1) assay was used to assess cell viability. All groups exhibited cell viability rates of >100%. Female 7-week-old Sprague-Dawley rats were used forin vivoexperiments. Calvarial defects were introduced on the rats' skulls using a 5.5 mm trephine bur. The rats were divided into the PCL (control), PCL/Leptin, and PCL/Osteo scaffold groups. The scaffolds were then inserted into the calvarial defect areas, and the rats were sacrificed after 8-weeks to analyze the defect area. Micro-CT analysis indicated that the leptin- and osteolectin-coated scaffolds exhibited significantly higher bone regeneration. Histological analysis revealed new bone and blood vessels in the calvarial defect area. These findings indicate that the 3D-printed PCL scaffold allows for patient-customized fabrication as well as the easy application of proteins like leptin and osteolectin. Moreover, leptin and osteolectin did not show cytotoxicity and exhibited higher bone regeneration potential than the existing scaffold.
Collapse
Affiliation(s)
- Young-Ran Kim
- Department of Biomedical Engineering, College of Dentistry, Chonnam National University, Gwangju, Republic of Korea
| | - Eun-Byeol Yun
- College of Dentistry, Chonnam National University, Gwangju, Republic of Korea
| | - Dam-In Ryu
- College of Dentistry, Chonnam National University, Gwangju, Republic of Korea
| | - Bo-Hye Kim
- Department of Veterinary Anatomy and Animal Behavior, College of Veterinary Medicine and BK21 FOUR Program, Chonnam National University, Gwangju, Republic of Korea
| | - Joong-Seon Kim
- Department of Veterinary Anatomy and Animal Behavior, College of Veterinary Medicine and BK21 FOUR Program, Chonnam National University, Gwangju, Republic of Korea
| | - Ye-Seul Kim
- Department of Prosthodontics, College of Dentistry, Chonnam National University, Gwangju, Republic of Korea
| | - Jin-Ho Kang
- Department of Prosthodontics, College of Dentistry, Chonnam National University, Gwangju, Republic of Korea
| | - Eun-Hyo Cho
- Department of Conservative Dentistry, College of Dentistry, Chonnam National University, Gwangju, Republic of Korea
| | - Jeong-Tae Koh
- Department of Pharmacology and Dental Therapeutics, College of Dentistry, Chonnam National University, Gwangju, Republic of Korea
| | - Hyun-Pil Lim
- Department of Prosthodontics, College of Dentistry, Chonnam National University, Gwangju, Republic of Korea
| | - Chan Park
- Department of Prosthodontics, College of Dentistry, Chonnam National University, Gwangju, Republic of Korea
| | - Bin-Na Lee
- Department of Conservative Dentistry, College of Dentistry, Chonnam National University, Gwangju, Republic of Korea
| |
Collapse
|
4
|
Su H, Fujiwara T, Skalli O, Selders GS, Li T, Mao L, Bumgardner JD. Porous Nano-Fiber Structure of Modified Electrospun Chitosan GBR Membranes Improve Osteoblast Calcium Phosphate Deposition in Osteoblast-Fibroblast Co-Cultures. Mar Drugs 2024; 22:160. [PMID: 38667777 PMCID: PMC11051071 DOI: 10.3390/md22040160] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Revised: 03/23/2024] [Accepted: 03/27/2024] [Indexed: 04/28/2024] Open
Abstract
Desirable characteristics of electrospun chitosan membranes (ESCM) for guided bone regeneration are their nanofiber structure that mimics the extracellular fiber matrix and porosity for the exchange of signals between bone and soft tissue compartments. However, ESCM are susceptible to swelling and loss of nanofiber and porous structure in physiological environments. A novel post-electrospinning method using di-tert-butyl dicarbonate (tBOC) prevents swelling and loss of nanofibrous structure better than sodium carbonate treatments. This study aimed to evaluate the hypothesis that retention of nanofiber morphology and high porosity of tBOC-modified ESCM (tBOC-ESCM) would support more bone mineralization in osteoblast-fibroblast co-cultures compared to Na2CO3 treated membranes (Na2CO3-ESCM) and solution-cast chitosan solid films (CM-film). The results showed that only the tBOC-ESCM retained the nanofibrous structure and had approximately 14 times more pore volume than Na2CO3-ESCM and thousands of times more pore volume than CM-films, respectively. In co-cultures, the tBOC-ESCM resulted in a significantly greater calcium-phosphate deposition by osteoblasts than either the Na2CO3-ESCM or CM-film (p < 0.05). This work supports the study hypothesis that tBOC-ESCM with nanofiber structure and high porosity promotes the exchange of signals between osteoblasts and fibroblasts, leading to improved mineralization in vitro and thus potentially improved bone healing and regeneration in guided bone regeneration applications.
Collapse
Affiliation(s)
- Hengjie Su
- Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China
- Department of Biomedical Engineering, University of Tennessee Health Science Center-Memphis Joint Graduate Biomedical Engineering Program, The University of Memphis, Memphis, TN 38152, USA
| | - Tomoko Fujiwara
- Department of Chemistry, The University of Memphis, Memphis, TN 38152, USA;
| | - Omar Skalli
- Integrated Microscopy Center, The University of Memphis, Memphis, TN 38152, USA
| | - Gretchen Schreyack Selders
- Department of Biomedical Engineering, University of Tennessee Health Science Center-Memphis Joint Graduate Biomedical Engineering Program, The University of Memphis, Memphis, TN 38152, USA
| | - Ting Li
- Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China
| | - Linna Mao
- Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China
| | - Joel D. Bumgardner
- Department of Biomedical Engineering, University of Tennessee Health Science Center-Memphis Joint Graduate Biomedical Engineering Program, The University of Memphis, Memphis, TN 38152, USA
| |
Collapse
|
5
|
Takallu S, Mirzaei E, Zakeri Bazmandeh A, Ghaderi Jafarbeigloo HR, Khorshidi H. Addressing Antimicrobial Properties in Guided Tissue/Bone Regeneration Membrane: Enhancing Effectiveness in Periodontitis Treatment. ACS Infect Dis 2024; 10:779-807. [PMID: 38300991 DOI: 10.1021/acsinfecdis.3c00568] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2024]
Abstract
Guided tissue regeneration (GTR) and guided bone regeneration (GBR) are the two surgical techniques generally used for periodontitis disease treatment. These techniques are based on a barrier membrane to direct the growth of new bone and gingival tissue at sites with insufficient volumes or dimensions of bone or gingiva for proper function, esthetics, or prosthetic restoration. Numerous studies have highlighted biocompatibility, space-creation, cell-blocking, bioactivity, and proper handling as essential characteristics of a membrane's performance. Given that bacterial infection is the primary cause of periodontitis, we strongly believe that addressing the antimicrobial properties of these membranes is of utmost importance. Indeed, the absence of effective inhibition of periodontal pathogens has been recognized as a primary factor contributing to the failure of GTR/GBR membranes. Therefore, we suggest considering antimicrobial properties as one of the key factors in the design of GTR/GBR membranes. Antibiotics are potent medications frequently administered systemically to combat microbes and mitigate bacterial infections. Nevertheless, the excessive use of antibiotics has resulted in a surge in bacterial resistance. To overcome this challenge, alternative antibacterial substances have been developed. In this review, we explore the utilization of alternative substances with antimicrobial properties for topical application in membranes. The use of antibacterial nanoparticles, phytochemical compounds, and antimicrobial peptides in this context was investigated. By carefully selecting and integrating antimicrobial agents into GTR/GBR membranes, we can significantly enhance their effectiveness in combating periodontitis. These antibacterial substances not only act as barriers against pathogenic bacteria but also promote the process of periodontal healing.
Collapse
Affiliation(s)
- Sara Takallu
- Department of Medical Nanotechnology, School of Advanced Medical Sciences and Technologies, Shiraz University of Medical Sciences, Shiraz 7133654361, Iran
| | - Esmaeil Mirzaei
- Department of Medical Nanotechnology, School of Advanced Medical Sciences and Technologies, Shiraz University of Medical Sciences, Shiraz 7133654361, Iran
| | - Abbas Zakeri Bazmandeh
- Department of Medical Nanotechnology, School of Advanced Medical Sciences and Technologies, Shiraz University of Medical Sciences, Shiraz 7133654361, Iran
| | - Hamid Reza Ghaderi Jafarbeigloo
- Department of Tissue Engineering, School of Advanced Technologies in Medicine, University of Medical Sciences, Fasa 7461686688, Iran
- Student Research Center committee, Fasa University of Medical Sciences, Fasa 7461686688, Iran
| | - Hooman Khorshidi
- Department of Periodontology, School of Dentistry, Shiraz University of Medical Sciences, Shiraz 7195615878, Iran
| |
Collapse
|
6
|
Kim K, Su Y, Kucine AJ, Cheng K, Zhu D. Guided Bone Regeneration Using Barrier Membrane in Dental Applications. ACS Biomater Sci Eng 2023; 9:5457-5478. [PMID: 37650638 DOI: 10.1021/acsbiomaterials.3c00690] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
Abstract
Guided bone regeneration (GBR) is a widely used technique in preclinical and clinical studies due to its predictability. Its main purpose is to prevent the migration of soft tissue into the osseous wound space, while allowing osseous cells to migrate to the site. GBR is classified into two main categories: resorbable and non-resorbable membranes. Resorbable membranes do not require a second surgery but tend to have a short resorption period. Conversely, non-resorbable membranes maintain their mechanical strength and prevent collapse. However, they require removal and are susceptible to membrane exposure. GBR is often used with bone substitute graft materials to fill the defect space and protect the bone graft. The membrane can also undergo various modifications, such as surface modification and biological factor loading, to improve barrier functions and bone regeneration. In addition, bone regeneration is largely related to osteoimmunology, a new field that focuses on the interactions between bone and the immune system. Understanding these interactions can help in developing new treatments for bone diseases and injuries. Overall, GBR has the potential to be a powerful tool in promoting bone regeneration. Further research in this area could lead to advancements in the field of bone healing. This review will highlight resorbable and non-resorbable membranes with cellular responses during bone regeneration, provide insights into immunological response during bone remodeling, and discuss antibacterial features.
Collapse
Affiliation(s)
- Kakyung Kim
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York 11794, United States
| | - Yingchao Su
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York 11794, United States
| | - Allan J Kucine
- Department of Oral and Maxillofacial Surgery, Stony Brook University, Stony Brook, New York 11794, United States
| | - Ke Cheng
- Department of Biomedical Engineering, Columbia University, New York City, New York 10027, United States
| | - Donghui Zhu
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York 11794, United States
| |
Collapse
|
7
|
Abtahi S, Chen X, Shahabi S, Nasiri N. Resorbable Membranes for Guided Bone Regeneration: Critical Features, Potentials, and Limitations. ACS MATERIALS AU 2023; 3:394-417. [PMID: 38089090 PMCID: PMC10510521 DOI: 10.1021/acsmaterialsau.3c00013] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/05/2023] [Revised: 06/01/2023] [Accepted: 06/02/2023] [Indexed: 03/22/2024]
Abstract
Lack of horizontal and vertical bone at the site of an implant can lead to significant clinical problems that need to be addressed before implant treatment can take place. Guided bone regeneration (GBR) is a commonly used surgical procedure that employs a barrier membrane to encourage the growth of new bone tissue in areas where bone has been lost due to injury or disease. It is a promising approach to achieve desired repair in bone tissue and is widely accepted and used in approximately 40% of patients with bone defects. In this Review, we provide a comprehensive examination of recent advances in resorbable membranes for GBR including natural materials such as chitosan, collagen, silk fibroin, along with synthetic materials such as polyglycolic acid (PGA), polycaprolactone (PCL), polyethylene glycol (PEG), and their copolymers. In addition, the properties of these materials including foreign body reaction, mechanical stability, antibacterial property, and growth factor delivery performance will be compared and discussed. Finally, future directions for resorbable membrane development and potential clinical applications will be highlighted.
Collapse
Affiliation(s)
- Sara Abtahi
- NanoTech
Laboratory, School of Engineering, Faculty of Science and Engineering, Macquarie University, Sydney 2109, Australia
- Department
of Dental Biomaterials, School of Dentistry, Tehran University of Medical Sciences, Tehran 1416753955, Iran
| | - Xiaohu Chen
- NanoTech
Laboratory, School of Engineering, Faculty of Science and Engineering, Macquarie University, Sydney 2109, Australia
| | - Sima Shahabi
- Department
of Dental Biomaterials, School of Dentistry, Tehran University of Medical Sciences, Tehran 1416753955, Iran
| | - Noushin Nasiri
- NanoTech
Laboratory, School of Engineering, Faculty of Science and Engineering, Macquarie University, Sydney 2109, Australia
| |
Collapse
|
8
|
Arunjaroensuk S, Thunyakitpisal P, Nampuksa K, Monmaturapoj N, Mattheos N, Pimkhaokham A. Stability of guided bone regeneration with two ratios of biphasic calcium phosphate at implant sites in the esthetic zone: A randomized controlled clinical trial. Clin Oral Implants Res 2023; 34:850-862. [PMID: 37314107 DOI: 10.1111/clr.14113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2022] [Revised: 05/23/2023] [Accepted: 05/30/2023] [Indexed: 06/15/2023]
Abstract
AIMS The aim of this randomized, double-blind, clinical trial was to compare the stability of the horizontal dimensions (facial bone thickness) of augmented bone using biphasic calcium phosphate (BCP) with hydroxyapatite/β-tricalcium phosphate ratio of either 60/40 or 70/30. MATERIALS AND METHODS Sixty dental implants placed with contour augmentation in the esthetic zone were randomized to 60/40 BCP (n = 30) or 70/30 BCP (n = 30). Cone-beam computed tomographic was used to assess facial bone thickness post-implantation and 6 months later at implant platform and 2, 4, and 6 mm apical to it. RESULTS The percentage of horizontal dimension reduction was 23.64%, 12.83%, 9.62%, and 8.21% in 70/30 BCP group, while 44.26%, 31.91%, 25.88%, and 21.49% in 60/40 BCP group at the level of the implant platform and 2, 4, and 6 mm apical, respectively. Statistically significant difference was found at 6 months at all levels of measurement (p-value < .05). CONCLUSIONS BCP bone grafts with HA/β-TCP ratio of 60/40 and 70/30 showed comparable outcomes for contour augmentation simultaneously with implant placement. Interestingly, the 70/30 ratio was significantly superior in maintaining facial thickness and showed more stable horizontal dimensions of the augmented site.
Collapse
Affiliation(s)
- Sirida Arunjaroensuk
- Dental Biomaterials Science Program, Graduate School, Chulalongkorn University, Bangkok, Thailand
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| | - Pasutha Thunyakitpisal
- Research Unit of Herbal Medicine, Biomaterials and Materials for Dental Treatment, Department of Anatomy, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| | - Katanchalee Nampuksa
- Assistive Technology and Medical Devices Research Center (A-MED), National Science and Technology Development Agency (NSTDA), Pathum Thani, Thailand
| | - Naruporn Monmaturapoj
- Assistive Technology and Medical Devices Research Center (A-MED), National Science and Technology Development Agency (NSTDA), Pathum Thani, Thailand
| | - Nikos Mattheos
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
- Department of Dental Medicine, Karolinska Institute, Stockholm, Sweden
| | - Atiphan Pimkhaokham
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| |
Collapse
|
9
|
Opris H, Baciut M, Bran S, Dinu C, Opris D, Armencea G, Onisor F, Bumbu B, Baciut G. Biocompatibility and histological responses of eggshell membrane for dental implant-guided bone regeneration. J Med Life 2023; 16:1007-1012. [PMID: 37900060 PMCID: PMC10600669 DOI: 10.25122/jml-2023-0267] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Accepted: 06/22/2023] [Indexed: 10/31/2023] Open
Abstract
Guided bone regeneration (GBR) utilizing eggshell membrane (ESM) as a potential biomaterial for dental implant therapy augmentation was explored in this study. ESM, an environmentally friendly waste product, possesses collagen-rich characteristics. The biocompatibility and histological responses of ESM were investigated in a rat model. Twelve young adult Wistar rats were used in this study. ESM samples were implanted in subcutaneous and intramuscular pockets, and samples were collected at 48 hours, 4 weeks, and 8 weeks post-implantation. Histological analysis revealed the changes in ESM over time. Results showed that ESM maintained its structural integrity, induced a moderate cellular response, and exhibited slow degradation, indicating potential biocompatibility. However, the lack of organized collagen arrangement in ESM led to the formation of irregular and polymorphic spaces, allowing cell migration. Encapsulation of ESM by newly proliferating collagen fibers and multinucleated giant cells was observed at later time points, indicating a foreign body reaction. Crosslinking might improve its performance as a separation membrane, as it has the potential to resist enzymatic degradation and enhance biomechanical properties. In conclusion, ESM demonstrated biocompatibility, slow degradation, and lack of foreign body reaction. While not suitable as a complete separation membrane due to irregular collagen arrangement, further research involving crosslinking could enhance its properties, making it a viable option for guided bone regeneration applications in dental implant therapy. This study highlights the potential of repurposing waste materials for medical purposes and underscores the importance of controlled collagen structure in biomaterial development.
Collapse
Affiliation(s)
- Horia Opris
- Maxillofacial Surgery and Implantology, Faculty of Medicine, Iuliu Hatieganu University of Pharmacy and Medicine, Cluj-Napoca, Romania
| | - Mihaela Baciut
- Maxillofacial Surgery and Implantology, Faculty of Medicine, Iuliu Hatieganu University of Pharmacy and Medicine, Cluj-Napoca, Romania
| | - Simion Bran
- Maxillofacial Surgery and Implantology, Faculty of Medicine, Iuliu Hatieganu University of Pharmacy and Medicine, Cluj-Napoca, Romania
| | - Cristian Dinu
- Maxillofacial Surgery and Implantology, Faculty of Medicine, Iuliu Hatieganu University of Pharmacy and Medicine, Cluj-Napoca, Romania
| | - Daiana Opris
- Maxillofacial Surgery and Implantology, Faculty of Medicine, Iuliu Hatieganu University of Pharmacy and Medicine, Cluj-Napoca, Romania
| | - Gabriel Armencea
- Maxillofacial Surgery and Implantology, Faculty of Medicine, Iuliu Hatieganu University of Pharmacy and Medicine, Cluj-Napoca, Romania
| | - Florin Onisor
- Maxillofacial Surgery and Implantology, Faculty of Medicine, Iuliu Hatieganu University of Pharmacy and Medicine, Cluj-Napoca, Romania
| | - Bogdan Bumbu
- Department of Oral Surgery, Faculty of Medicine and Pharmacy, University of Oradea, Oradea, Romania
| | - Grigore Baciut
- Maxillofacial Surgery and Implantology, Faculty of Medicine, Iuliu Hatieganu University of Pharmacy and Medicine, Cluj-Napoca, Romania
| |
Collapse
|
10
|
Agrawal AA. Platelet rich fibrin is not a barrier membrane! Or is it? World J Clin Cases 2023; 11:2396-2404. [PMID: 37123322 PMCID: PMC10131006 DOI: 10.12998/wjcc.v11.i11.2396] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/01/2023] [Revised: 01/27/2023] [Accepted: 03/17/2023] [Indexed: 04/06/2023] Open
Abstract
Platelet-rich fibrin (PRF) is widely used in dentistry and other fields of medicine, and its use has become popular in dental implantology. In several published studies, PRF has been used as a barrier membrane. A barrier membrane is a sheet of a certain material that acts as a biological and mechanical barrier against the invasion of cells that are not involved in bone formation, such as epithelial cells. Among the basic requirements of a 'barrier membrane, occlusivity, stiffness, and space maintenance are the criteria that PRF primarily lacks; therefore, it does not fall under the category of barrier membranes. However, there is evidence that PRF membranes are useful in significantly improving wound healing. Does the PRF membrane act as a barrier? Should we think of adding or subtracting some points from the ideal requirements of a barrier membrane, or should we coin a new term or concept for PRF that will incorporate some features of a barrier membrane and be a combination of tissue engineering and biotechnology? This review is aimed at answering the basic question of whether the PRF membrane should be considered a barrier membrane or whether it is something more beyond the boundaries of a barrier membrane.
Collapse
Affiliation(s)
- Amit Arvind Agrawal
- Department of Periodontology and Implantology, Mahatma Gandhi Vidyamandir's Karmaveer Bhausaheb Hiray Dental College and Hospital, Nasik 422003, India
| |
Collapse
|
11
|
Sehgal V, Ruangsawasdi N, Kiattavorncharoen S, Bencharit S, Thanasrisuebwong P. Occlusive and Proliferative Properties of Different Collagen Membranes-An In Vitro Study. MATERIALS (BASEL, SWITZERLAND) 2023; 16:1657. [PMID: 36837285 PMCID: PMC9964610 DOI: 10.3390/ma16041657] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Revised: 02/03/2023] [Accepted: 02/13/2023] [Indexed: 06/18/2023]
Abstract
Different collagen barrier membranes come in various sources and crosslinking that may affect barrier function and tissue integration. This study investigated barrier function and tissue integration of the three different collagen membranes (Jason®: porcine pericardium, GENOSS: bovine tendon, and BioMend® Extend: cross-linked bovine tendon) with human gingival fibroblasts. The barrier function and tissue integration properties were determined under confocal microscopy. Morphological characteristics were observed using scanning electron microscopy. Our results showed that all collagen membranes allowed a small number of cells to migrate, and the difference in barrier function ability was not significant. The cross-linked characteristics did not improve barrier ability. The native collagen membrane surfaces allowed evenly scattered proliferation of HGF, while the cross-linked collagen membrane induced patchy proliferation. Statistically significant differences in cell proliferation were found between Jason and BioMend Extend membranes (p = 0.04). Scanning electron microscope showed a compact membrane surface at the top, while the bottom surfaces displayed interwoven collagen fibers, which were denser in the crosslinked collagen membranes. Within the limitations of this study, collagen membranes of different origins and physical properties can adequately prevent the invasion of unwanted cells. Native collagen membranes may provide a better surface for gingival cell attachment and proliferation.
Collapse
Affiliation(s)
- Vishal Sehgal
- Master of Science Program in Implant Dentistry, Faculty of Dentistry, Mahidol University, Bangkok 10400, Thailand
| | - Nisarat Ruangsawasdi
- Department of Pharmacology, Faculty of Dentistry, Mahidol University, Bangkok 10400, Thailand
| | - Sirichai Kiattavorncharoen
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Mahidol University, Bangkok 10400, Thailand
| | - Sompop Bencharit
- Office of Oral Health Innovation, Department of Oral Rehabilitation, The James B. Edwards College of Dental Medicine, Medical University of South Carolina, Charleston, SC 29425, USA
| | | |
Collapse
|
12
|
Ren Y, Fan L, Alkildani S, Liu L, Emmert S, Najman S, Rimashevskiy D, Schnettler R, Jung O, Xiong X, Barbeck M. Barrier Membranes for Guided Bone Regeneration (GBR): A Focus on Recent Advances in Collagen Membranes. Int J Mol Sci 2022; 23:ijms232314987. [PMID: 36499315 PMCID: PMC9735671 DOI: 10.3390/ijms232314987] [Citation(s) in RCA: 46] [Impact Index Per Article: 23.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Revised: 11/25/2022] [Accepted: 11/25/2022] [Indexed: 12/02/2022] Open
Abstract
Guided bone regeneration (GBR) has become a clinically standard modality for the treatment of localized jawbone defects. Barrier membranes play an important role in this process by preventing soft tissue invasion outgoing from the mucosa and creating an underlying space to support bone growth. Different membrane types provide different biological mechanisms due to their different origins, preparation methods and structures. Among them, collagen membranes have attracted great interest due to their excellent biological properties and desired bone regeneration results to non-absorbable membranes even without a second surgery for removal. This work provides a comparative summary of common barrier membranes used in GBR, focusing on recent advances in collagen membranes and their biological mechanisms. In conclusion, the review article highlights the biological and regenerative properties of currently available barrier membranes with a particular focus on bioresorbable collagen-based materials. In addition, the advantages and disadvantages of these biomaterials are highlighted, and possible improvements for future material developments are summarized.
Collapse
Affiliation(s)
- Yanru Ren
- Clinic and Policlinic for Dermatology and Venereology, University Medical Center Rostock, 18057 Rostock, Germany
- BerlinAnalytix GmbH, 12109 Berlin, Germany
| | - Lu Fan
- NMI Natural and Medical Sciences Institute, University of Tübingen, 72770 Reutlingen, Germany
| | | | - Luo Liu
- Beijing Advanced Innovation Center for Soft Matter Science and Engineering, College of Life Science and Technology, Beijing University of Chemical Technology, Beijing 100013, China
| | - Steffen Emmert
- Clinic and Policlinic for Dermatology and Venereology, University Medical Center Rostock, 18057 Rostock, Germany
| | - Stevo Najman
- Scientific Research Center for Biomedicine, Department for Cell and Tissue Engineering, Faculty of Medicine, University of Niš, 18000 Niš, Serbia
- Department of Biology and Human Genetics, Faculty of Medicine, University of Niš, 18000 Niš, Serbia
| | - Denis Rimashevskiy
- Department of Traumatology and Orthopedics, Peoples’ Friendship University of Russia, 117198 Moscow, Russia
| | - Reinhard Schnettler
- University Medical Centre, Justus Liebig University of Giessen, 35390 Giessen, Germany
| | - Ole Jung
- Clinic and Policlinic for Dermatology and Venereology, University Medical Center Rostock, 18057 Rostock, Germany
| | - Xin Xiong
- NMI Natural and Medical Sciences Institute, University of Tübingen, 72770 Reutlingen, Germany
| | - Mike Barbeck
- Clinic and Policlinic for Dermatology and Venereology, University Medical Center Rostock, 18057 Rostock, Germany
- BerlinAnalytix GmbH, 12109 Berlin, Germany
- Beijing Advanced Innovation Center for Soft Matter Science and Engineering, College of Life Science and Technology, Beijing University of Chemical Technology, Beijing 100013, China
- Correspondence: ; Tel.: +49-(0)-176-81022467
| |
Collapse
|
13
|
Antibacterial Effect of Triazine in Barrier Membranes with Therapeutic Activity for Guided Bone Regeneration. Polymers (Basel) 2022; 14:polym14214482. [PMID: 36365476 PMCID: PMC9658774 DOI: 10.3390/polym14214482] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2022] [Revised: 10/17/2022] [Accepted: 10/18/2022] [Indexed: 11/07/2022] Open
Abstract
Objective: This study aimed to develop polymer-based barrier membranes based on poly(butylene-adipate-co-terephthalate) (PBAT) with the addition of 1,3,5-triacriloilhexahydro-1,3,5-triazine (TAT). Materials and Methods: Polymeric solutions were used to produce membranes with 5 wt% and 10 wt% of TAT by solvent casting. Membranes without the addition of TAT were used as controls. The membranes were chemically characterized by Fourier transform infrared spectroscopy (FTIR) and thermogravimetry (TGA); surface properties were assessed by profilometry and contact angle; the mechanical behavior was evaluated by a tensile test, and the biological properties were assessed by direct−indirect cell viability and antibacterial activity by S. mutans and S. aureus colony-forming units. Results: TAT was detected in the FTIR and TGA analyses and modified the top surface of the membranes, increasing their roughness and wetness in both concentrations compared to the control group (p < 0.05). The addition of TAT, regardless of concentration, reduced the tensile strength and increased membrane stiffness (p < 0.05). The cell viability of 5 wt% TAT and 10 wt% TAT was 86.37% and 82.36%, respectively. All tested concentrations reduced the formation of biofilm on the membranes when compared to the control. Conclusion: The addition of TAT successfully resulted in the antimicrobial ability of PBAT-based barrier membranes, while it maintained acceptable levels of cell viability in membranes with adequate handling and surface properties.
Collapse
|
14
|
Effect of Different Membranes on Vertical Bone Regeneration: A Systematic Review and Network Meta-Analysis. BIOMED RESEARCH INTERNATIONAL 2022; 2022:7742687. [PMID: 35872861 PMCID: PMC9303140 DOI: 10.1155/2022/7742687] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/10/2022] [Revised: 05/17/2022] [Accepted: 06/27/2022] [Indexed: 11/17/2022]
Abstract
This study is aimed at performing a systematic review and a network meta-analysis of the effects of several membranes on vertical bone regeneration and clinical complications in guided bone regeneration (GBR) or guided tissue regeneration (GTR). We compared the effects of the following membranes: high-density polytetrafluoroethylene (d-PTFE), expanded polytetrafluoroethylene (e-PTFE), crosslinked collagen membrane (CCM), noncrosslinked collagen membrane (CM), titanium mesh (TM), titanium mesh plus noncrosslinked (TM + CM), titanium mesh plus crosslinked (TM + CCM), titanium-reinforced d-PTFE, titanium-reinforced e-PTFE, polylactic acid (PLA), polyethylene glycol (PEG), and polylactic acid 910 (PLA910). Using the PICOS principles to help determine inclusion criteria, articles are collected using PubMed, Web of Science, and other databases. Assess the risk of deviation and the quality of evidence using the Cochrane Evaluation Manual, and GRADE. 27 articles were finally included. 19 articles were included in a network meta-analysis with vertical bone increment as an outcome measure. The network meta-analysis includes network diagrams, paired-comparison forest diagrams, funnel diagrams, surface under the cumulative ranking curve (SUCRA) diagrams, and sensitivity analysis diagrams. SUCRA indicated that titanium-reinforced d-PTFE exhibited the highest vertical bone increment effect. Meanwhile, we analyzed the complications of 19 studies and found that soft tissue injury and membrane exposure were the most common complications.
Collapse
|
15
|
Yang Z, Wu C, Shi H, Luo X, Sun H, Wang Q, Zhang D. Advances in Barrier Membranes for Guided Bone Regeneration Techniques. Front Bioeng Biotechnol 2022; 10:921576. [PMID: 35814003 PMCID: PMC9257033 DOI: 10.3389/fbioe.2022.921576] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2022] [Accepted: 05/30/2022] [Indexed: 11/13/2022] Open
Abstract
Guided bone regeneration (GBR) is a widely used technique for alveolar bone augmentation. Among all the principal elements, barrier membrane is recognized as the key to the success of GBR. Ideal barrier membrane should have satisfactory biological and mechanical properties. According to their composition, barrier membranes can be divided into polymer membranes and non-polymer membranes. Polymer barrier membranes have become a research hotspot not only because they can control the physical and chemical characteristics of the membranes by regulating the synthesis conditions but also because their prices are relatively low. Still now the bone augment effect of barrier membrane used in clinical practice is more dependent on the body’s own growth potential and the osteogenic effect is difficult to predict. Therefore, scholars have carried out many researches to explore new barrier membranes in order to improve the success rate of bone enhancement. The aim of this study is to collect and compare recent studies on optimizing barrier membranes. The characteristics and research progress of different types of barrier membranes were also discussed in detail.
Collapse
Affiliation(s)
- Ze Yang
- Liaoning Provincial Key Laboratory of Oral Diseases, School and Hospital of Stomatology, China Medical University, Shenyang, China
| | - Chang Wu
- Liaoning Provincial Key Laboratory of Oral Diseases, School and Hospital of Stomatology, China Medical University, Shenyang, China
| | - Huixin Shi
- Department of Plastic Surgery, The First Affiliated Hospital of China Medical University, Shenyang, China
| | - Xinyu Luo
- Liaoning Provincial Key Laboratory of Oral Diseases, School and Hospital of Stomatology, China Medical University, Shenyang, China
| | - Hui Sun
- Liaoning Provincial Key Laboratory of Oral Diseases, School and Hospital of Stomatology, China Medical University, Shenyang, China
| | - Qiang Wang
- Liaoning Provincial Key Laboratory of Oral Diseases, School and Hospital of Stomatology, China Medical University, Shenyang, China
- *Correspondence: Qiang Wang, ; Dan Zhang,
| | - Dan Zhang
- Liaoning Provincial Key Laboratory of Oral Diseases, School and Hospital of Stomatology, China Medical University, Shenyang, China
- *Correspondence: Qiang Wang, ; Dan Zhang,
| |
Collapse
|
16
|
Barros RM, Da Silva CG, Nicolau Costa KM, Da Silva-Junior AA, Scardueli CR, Marcantonio RAC, Chiavacci LA, Oshiro-Junior JA. Dexamethasone-Loaded Ureasil Hydrophobic Membrane for Bone Guided Regeneration. Pharmaceutics 2022; 14:1027. [PMID: 35631613 PMCID: PMC9146579 DOI: 10.3390/pharmaceutics14051027] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Revised: 05/07/2022] [Accepted: 05/09/2022] [Indexed: 01/09/2023] Open
Abstract
Physical barrier membranes have been used to release active substances to treat critical bone defects; however, hydrophilic membranes do not present a prolonged release capacity. In this sense, hydrophobic membranes have been tested. Thus, this study aimed to develop hydrophobic membranes based on mixtures of ureasil-polyether-type materials containing incorporated dexamethasone (DMA) for the application in guided bone regeneration. The physicochemical characterization and biological assays were carried out using small-angle X-ray scattering (SAXS), an in vitro DMA release study, atomic force microscopy (AFM), a hemolysis test, and in vivo bone formation. The swelling degree, SAXS, and release results revealed that the u-PPO400/2000 membrane in the proportion of 70:30 showed swelling (4.69% ± 0.22) similar to the proportions 90:10 and 80:20, and lower than the proportion 60:40 (6.38% ± 0.49); however, an equal release percentage after 134 h was observed between the proportions 70:30 and 60:40. All u-PPO materials presented hemocompatibility (hemolysis ≤2.8%). AFM results showed that the treatments with or without DMA did not present significant differences, revealing a flat/smooth surface, with no pores and/or crystalline precipitates. Finally, in vivo results revealed that for both the commercial hydrophilic membrane and u-PPO400/2000 (70:30) after 60 days, the bone formation volume was 21%. In conclusion, hybrid membranes present unique characteristics for treating critical bone defects, considering the delayed and prolonged release results associated with the physical barrier capacity.
Collapse
Affiliation(s)
- Rafaella Moreno Barros
- Pharmaceutical Sciences Postgraduate Center for Biological and Health Sciences, State University of Paraíba, Av. Juvêncio Arruda, S/N, Campina Grande 58429-600, Paraíba, Brazil; (R.M.B.); (K.M.N.C.)
| | - Camila Garcia Da Silva
- Department of Drugs and Medicines, School of Pharmaceutical Sciences, São Paulo State University (UNESP), Highway Araraquara-Jaú, Araraquara 14801-902, São Paulo, Brazil;
| | - Kammila Martins Nicolau Costa
- Pharmaceutical Sciences Postgraduate Center for Biological and Health Sciences, State University of Paraíba, Av. Juvêncio Arruda, S/N, Campina Grande 58429-600, Paraíba, Brazil; (R.M.B.); (K.M.N.C.)
| | - Arnóbio A. Da Silva-Junior
- Department of Pharmacy, Federal University of Rio Grande do Norte-UFRN, Natal 59012-570, Rio Grande do Norte, Brazil;
| | - Cássio Rocha Scardueli
- Faculty of Dentistry, São Paulo State University (UNESP), Araraquara 14801-385, São Paulo, Brazil; (C.R.S.); (R.A.C.M.)
| | | | - Leila Aparecida Chiavacci
- Department of Drugs and Medicines, School of Pharmaceutical Sciences, São Paulo State University (UNESP), Highway Araraquara-Jaú, Araraquara 14801-902, São Paulo, Brazil;
| | - João Augusto Oshiro-Junior
- Pharmaceutical Sciences Postgraduate Center for Biological and Health Sciences, State University of Paraíba, Av. Juvêncio Arruda, S/N, Campina Grande 58429-600, Paraíba, Brazil; (R.M.B.); (K.M.N.C.)
| |
Collapse
|
17
|
Lindner C, Alkildani S, Stojanovic S, Najman S, Jung O, Barbeck M. In Vivo Biocompatibility Analysis of a Novel Barrier Membrane Based on Bovine Dermis-Derived Collagen for Guided Bone Regeneration (GBR). MEMBRANES 2022; 12:membranes12040378. [PMID: 35448348 PMCID: PMC9027842 DOI: 10.3390/membranes12040378] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Revised: 03/24/2022] [Accepted: 03/28/2022] [Indexed: 12/19/2022]
Abstract
Collagen-based barrier membranes are nowadays the prevalent option for Guided Bone Regeneration (GBR) procedures. Xenogeneic collagen is highly biocompatible as it shares a similar structure to native human collagen, which prevents it from eliciting an exaggerated host immune response. Most commercially available collagen barrier membranes are porcine-derived, while bovine-derived alternatives are still rarely available. The aim of the present study was to investigate the tissue responses and the barrier functionality of a novel GBR membrane composed of bovine collagen type I (BM). Therefore, the subcutaneous implantation model in Wistar rats was performed to compare the novel medical device with two already clinically used native porcine-based barrier membranes, i.e., Jason® membrane (JM) and Bio-Gide® (BG), at 10-, 30-, 60-, and 90-days post implantationem. Histochemical and immunohistochemical stains were used for histopathological evaluation including a biocompatibility scoring according to the DIN EN ISO 10993-6 norm as well as histomorphometrical analyses of the occurrence of M1 and M2 macrophages and the transmembraneous vascularization. The bovine membrane exhibited a host tissue reaction that was comparable to both control materials, which was verified by the scoring results and the histomorphometrical macrophage measurements. Moreover, the novel membrane exhibited an integration pattern without material fragmentation up to day 60. At day 90, material fragmentation was observable that allowed for “secondary porosity” including transmembrane vascularization. The results of this study suggest that the novel bovine barrier membrane is fully biocompatible and suitable for indications that require GBR as a suitable alternative to porcine-sourced barrier membranes.
Collapse
Affiliation(s)
| | - Said Alkildani
- BerlinAnalytix GmbH, 12109 Berlin, Germany; (C.L.); (S.A.)
| | - Sanja Stojanovic
- Department for Cell and Tissue Engineering, Faculty of Medicine, University of Niš, 18000 Nis, Serbia; (S.S.); (S.N.)
- Department of Biology and Human Genetics, Faculty of Medicine, University of Niš, 18000 Nis, Serbia
| | - Stevo Najman
- Department for Cell and Tissue Engineering, Faculty of Medicine, University of Niš, 18000 Nis, Serbia; (S.S.); (S.N.)
- Department of Biology and Human Genetics, Faculty of Medicine, University of Niš, 18000 Nis, Serbia
| | - Ole Jung
- Clinic and Policlinic for Dermatology and Venereology, University Medical Center Rostock, 18057 Rostock, Germany;
| | - Mike Barbeck
- BerlinAnalytix GmbH, 12109 Berlin, Germany; (C.L.); (S.A.)
- Clinic and Policlinic for Dermatology and Venereology, University Medical Center Rostock, 18057 Rostock, Germany;
- Correspondence: ; Tel.: +49-176-81022467
| |
Collapse
|
18
|
Jung O, Hesse B, Stojanovic S, Seim C, Weitkamp T, Batinic M, Goerke O, Kačarević ŽP, Rider P, Najman S, Barbeck M. Biocompatibility Analyses of HF-Passivated Magnesium Screws for Guided Bone Regeneration (GBR). Int J Mol Sci 2021; 22:ijms222212567. [PMID: 34830451 PMCID: PMC8624161 DOI: 10.3390/ijms222212567] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Revised: 11/19/2021] [Accepted: 11/19/2021] [Indexed: 11/17/2022] Open
Abstract
Background: Magnesium (Mg) is one of the most promising materials for human use in surgery due to material characteristics such as its elastic modulus as well as its resorbable and regenerative properties. In this study, HF-coated and uncoated novel bioresorbable magnesium fixation screws for maxillofacial and dental surgical applications were investigated in vitro and in vivo to evaluate the biocompatibility of the HF coating. Methods: Mg alloy screws that had either undergone a surface treatment with hydrofluoric-acid (HF) or left untreated were investigated. In vitro investigation included XTT, BrdU and LDH in accordance with the DIN ISO 10993-5/-12. In vivo, the screws were implanted into the tibia of rabbits. After 3 and 6 weeks, degradation, local tissue reactions and bony integration were analyzed histopathologically and histomorphometrically. Additionally, SEM/EDX analysis and synchrotron phase-contrast microtomography (µCT) measurements were conducted. The in vitro analyses revealed that the Mg screws are cytocompatible, with improved results when the surface had been passivated with HF. In vivo, the HF-treated Mg screws implanted showed a reduction in gas formation, slower biodegradation and a better bony integration in comparison to the untreated Mg screws. Histopathologically, the HF-passivated screws induced a layer of macrophages as part of its biodegradation process, whereas the untreated screws caused a slight fibrous tissue reaction. SEM/EDX analysis showed that both screws formed a similar layer of calcium phosphates on their surfaces and were surrounded by bone. Furthermore, the µCT revealed the presence of a metallic core of the screws, a faster absorbing corrosion front and a slow absorbing region of corroded magnesium. Conclusions: Overall, the HF-passivated Mg fixation screws showed significantly better biocompatibility in vitro and in vivo compared to the untreated screws.
Collapse
Affiliation(s)
- Ole Jung
- Clinic and Policlinic for Dermatology and Venereology, University Medical Center Rostock, 18057 Rostock, Germany;
| | | | - Sanja Stojanovic
- Department of Biology and Human Genetics, Faculty of Medicine, University of Niš, 18108 Niš, Serbia; (S.S.); (S.N.)
- Scientific Research Center for Biomedicine, Faculty of Medicine, Department for Cell and Tissue Engineering, University of Niš, 18108 Niš, Serbia
| | | | - Timm Weitkamp
- Synchrotron SOLEIL, Gif-sur-Yvette, 91190 Saint-Aubin, France;
| | - Milijana Batinic
- Department of Ceramic Materials, Chair of Advanced Ceramic Materials, Institute for Materials Science and Technologies, Technical University of Berlin, 10623 Berlin, Germany; (M.B.); (O.G.)
- Department of Anatomy Histology, Embryology, Pathology Anatomy and Pathology Histology, Faculty of Dental Medicine and Health, University of Osijek, 31000 Osijek, Croatia;
| | - Oliver Goerke
- Department of Ceramic Materials, Chair of Advanced Ceramic Materials, Institute for Materials Science and Technologies, Technical University of Berlin, 10623 Berlin, Germany; (M.B.); (O.G.)
| | - Željka Perić Kačarević
- Department of Anatomy Histology, Embryology, Pathology Anatomy and Pathology Histology, Faculty of Dental Medicine and Health, University of Osijek, 31000 Osijek, Croatia;
| | - Patrick Rider
- Department of Anatomy Histology, Embryology, Pathology Anatomy and Pathology Histology, Faculty of Dental Medicine and Health, University of Osijek, 31000 Osijek, Croatia;
| | - Stevo Najman
- Department of Biology and Human Genetics, Faculty of Medicine, University of Niš, 18108 Niš, Serbia; (S.S.); (S.N.)
- Scientific Research Center for Biomedicine, Faculty of Medicine, Department for Cell and Tissue Engineering, University of Niš, 18108 Niš, Serbia
| | - Mike Barbeck
- Department of Anatomy Histology, Embryology, Pathology Anatomy and Pathology Histology, Faculty of Dental Medicine and Health, University of Osijek, 31000 Osijek, Croatia;
- Correspondence: ; Tel.: +49-176-810-224-6
| |
Collapse
|
19
|
Ottenbacher N, Alkildani S, Korzinskas T, Pissarek J, Ulm C, Jung O, Sundag B, Bellmann O, Stojanovic S, Najman S, Zechner W, Barbeck M. Novel Histomorphometrical Approach to Evaluate the Integration Pattern and Functionality of Barrier Membranes. Dent J (Basel) 2021; 9:dj9110127. [PMID: 34821591 PMCID: PMC8618445 DOI: 10.3390/dj9110127] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Revised: 10/19/2021] [Accepted: 10/21/2021] [Indexed: 12/15/2022] Open
Abstract
GBR (guided bone regeneration) is a standard procedure for building up bony defects in the jaw. In this procedure, resorbable membranes made of bovine and porcine collagen are increasingly being used, which, in addition to many possible advantages, could have the potential disadvantage of a shorter barrier functionality, especially when augmenting large-volume defects. Thus, it is of importance to evaluate the integration behavior and especially the standing time of barrier membranes using specialized methods to predict its respective biocompatibility. This study is intended to establish a new histomorphometrical analysis method to quantify the integration rate of collagen-based barrier membranes. Three commercially available barrier membranes, i.e., non-crosslinked membranes (BioGide® and Jason® membrane), a ribose-crosslinked membrane (Ossix® Plus), and a newly developed collagen–hyaluronic acid-based (Coll-HA) barrier membrane were implanted in the subcutaneous tissue of 48 6–8-week-old Wistar rats. The explants, after three timepoints (10, 30, and 60 days), were processed and prepared into histological sections for histopathological (host tissue response) and histomorphometrical (cellular invasion) analyses. 10 days after implantation, fragmentation was not evident in any of the study groups. The sections of the Coll-HA, Jason® and BioGide® membranes showed a similar mild inflammatory reaction within the surrounding tissue and an initial superficial cell immigration. Only in the Ossix® Plus group very little inflammation and no cell invasion was detected. While the results of the three commercially available membranes remained intact in the further course of the study, only fragments of the Coll-HA membrane were found 30 and 60 days after implantation. Histomorphometrically, it can be described that although initially (at 10 days post-implantation) similar results were found in all study groups, after 30 days post-implantation the cellular penetration depth of the hyaluronic acid-collagen membrane was significantly increased with time (**** p < 0.0001). Similarly, the percentage of cellular invasion per membrane thickness was also significantly higher in the Coll-HA group at all timepoints, compared to the other membranes (**** p < 0.0001). Altogether, these results show that the histomorphometrical analysis of the cellular migration can act as an indicator of integration and duration of barrier functionality. Via this approach, it was possible to semi-quantify the different levels of cellular penetration of GBR membranes that were only qualitatively analyzed through histopathological approaches before. Additionally, the results of the histopathological and histomorphometrical analyses revealed that hyaluronic acid addition to collagen does not lead to a prolonged standing time, but an increased integration of a collagen-based biomaterial. Therefore, it can only partially be used in the dental field for indications that require fast resorbed membranes and a fast cell or tissue influx such as periodontal regeneration processes.
Collapse
Affiliation(s)
- Nicola Ottenbacher
- Clinical Division of Oral Surgery, Dental University Clinic, Medical University of Vienna, 1090 Vienna, Austria; (N.O.); (C.U.); (W.Z.)
| | - Said Alkildani
- BerlinAnalytix GmbH, 12109 Berlin, Germany; (S.A.); (T.K.)
| | | | | | - Christian Ulm
- Clinical Division of Oral Surgery, Dental University Clinic, Medical University of Vienna, 1090 Vienna, Austria; (N.O.); (C.U.); (W.Z.)
| | - Ole Jung
- Clinic and Policlinic for Dermatology and Venereology, University Medical Center Rostock, 18057 Rostock, Germany; (O.J.); (B.S.)
| | - Bernd Sundag
- Clinic and Policlinic for Dermatology and Venereology, University Medical Center Rostock, 18057 Rostock, Germany; (O.J.); (B.S.)
| | - Olaf Bellmann
- Research Institute for Farm Animal Biology (FBN), 18196 Dummerstorf, Germany;
| | - Sanja Stojanovic
- Scientific Research Center for Biomedicine, Department for Cell and Tissue Engineering, Faculty of Medicine, University of of Niš, 18000 Niš, Serbia; (S.S.); (S.N.)
- Department of Biology and Human Genetics, Faculty of Medicine, University of Niš, 18000 Niš, Serbia
| | - Stevo Najman
- Scientific Research Center for Biomedicine, Department for Cell and Tissue Engineering, Faculty of Medicine, University of of Niš, 18000 Niš, Serbia; (S.S.); (S.N.)
- Department of Biology and Human Genetics, Faculty of Medicine, University of Niš, 18000 Niš, Serbia
| | - Werner Zechner
- Clinical Division of Oral Surgery, Dental University Clinic, Medical University of Vienna, 1090 Vienna, Austria; (N.O.); (C.U.); (W.Z.)
- Austrian Cluster for Tissue Regeneration, 1200 Vienna, Austria
| | - Mike Barbeck
- Department of Ceramic Materials, Chair of Advanced Ceramic Materials, Institute for Materials Science and Technologies, Technical University Berlin, 10623 Berlin, Germany
- Correspondence: ; Tel.: +49-(0)-176-8102-2467
| |
Collapse
|
20
|
Sasaki JI, Abe GL, Li A, Thongthai P, Tsuboi R, Kohno T, Imazato S. Barrier membranes for tissue regeneration in dentistry. Biomater Investig Dent 2021; 8:54-63. [PMID: 34104896 PMCID: PMC8158285 DOI: 10.1080/26415275.2021.1925556] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Accepted: 04/29/2021] [Indexed: 12/14/2022] Open
Abstract
Background: In dentistry, barrier membranes are used for guided tissue regeneration (GTR) and guided bone regeneration (GBR). Various membranes are commercially available and extensive research and development of novel membranes have been conducted. In general, membranes are required to provide barrier function, biosafety, biocompatibility and appropriate mechanical properties. In addition, membranes are expected to be bioactive to promote tissue regeneration. Objectives: This review aims to organize the fundamental characteristics of the barrier membranes that are available and studied for dentistry, based on their components. Results: The principal components of barrier membranes are divided into nonbiodegradable and biodegradable materials. Nonbiodegradable membranes are manufactured from synthetic polymers, metals or composites of these materials. The first reported barrier membrane was made from expanded polytetrafluoroethylene (e-PTFE). Titanium has also been applied for dental regenerative therapy and shows favorable barrier function. Biodegradable membranes are mainly made from natural and synthetic polymers. Collagens are popular materials that are processed for clinical use by cross-linking. Aliphatic polyesters and their copolymers have been relatively recently introduced into GTR and GBR treatments. In addition, to improve the tissue regenerative function and mechanical strength of biodegradable membranes, inorganic materials such as calcium phosphate and bioactive glass have been incorporated at the research stage. Conclusions: Currently, there are still insufficient guidelines for barrier membrane choice in GTR and GBR, therefore dentists are required to understand the characteristics of barrier membranes.
Collapse
Affiliation(s)
- Jun-Ichi Sasaki
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, Suita, Japan
| | - Gabriela L. Abe
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, Suita, Japan
| | - Aonan Li
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, Suita, Japan
| | - Pasiree Thongthai
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, Suita, Japan
| | - Ririko Tsuboi
- Department of Advanced Functional Materials Science, Osaka University Graduate School of Dentistry, Suita, Japan
| | - Tomoki Kohno
- Department of Advanced Functional Materials Science, Osaka University Graduate School of Dentistry, Suita, Japan
| | - Satoshi Imazato
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, Suita, Japan
- Department of Advanced Functional Materials Science, Osaka University Graduate School of Dentistry, Suita, Japan
| |
Collapse
|
21
|
Balbinot GDS, Bahlis EADC, Visioli F, Leitune VCB, Soares RMD, Collares FM. Polybutylene-adipate-terephthalate and niobium-containing bioactive glasses composites: Development of barrier membranes with adjusted properties for guided bone regeneration. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 125:112115. [PMID: 33965098 DOI: 10.1016/j.msec.2021.112115] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2020] [Revised: 03/29/2021] [Accepted: 04/13/2021] [Indexed: 02/08/2023]
Abstract
This study aimed to develop bioactive guided bone regeneration (GBR) membranes by manufacturing PBAT/BAGNb composites as casting films. Composites were produced by melt-extrusion, and BAGNb was added at 10 wt%, 20 wt%, and 30 wt% concentration. Pure PBAT membranes were used as a control (0wt%BAGNb). FTIR and thermogravimetric analysis characterized the composites. Barrier membranes were produced by solvent casting, and their mechanical and surface properties were assessed by tensile strength test and contact angle analysis, respectively. The ion release and cell behavior were evaluated by pH, cell proliferation, and mineralization. Composites were successfully produced, and the chemical structure showed no interference of BAGNb in the PBAT structure. The addition of BAGNb increased the stiffness of the membranes and reduced the contact angle, increasing the roughness in one side of the membrane. Sustained pH increment was observed for BAGNb-containing membranes with increased proliferation and mineralization as the concentration of BAGNb increases. The incorporation of up to 30 wt% of BAGNb into PBAT barrier membranes was able to maintain adequate chemical-mechanical properties leading to the production of materials with tailored surface properties and bioactivity. Finally, this biomaterial class showed outstanding potential and may contribute to bone formation in GBR procedures.
Collapse
Affiliation(s)
- Gabriela de Souza Balbinot
- Dental Materials Laboratory, School of Dentistry, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS, Brazil.
| | | | - Fernanda Visioli
- Patology Laboratory, School of Dentistry, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS, Brazil.
| | | | | | - Fabricio Mezzomo Collares
- Dental Materials Laboratory, School of Dentistry, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS, Brazil.
| |
Collapse
|
22
|
Roca-Millan E, Jané-Salas E, Estrugo-Devesa A, López-López J. Evaluation of Bone Gain and Complication Rates after Guided Bone Regeneration with Titanium Foils: A Systematic Review. MATERIALS 2020; 13:ma13235346. [PMID: 33255825 PMCID: PMC7728364 DOI: 10.3390/ma13235346] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Revised: 11/15/2020] [Accepted: 11/23/2020] [Indexed: 02/07/2023]
Abstract
Guided bone regeneration techniques are increasingly used to enable the subsequent placement of dental implants. This systematic review aims to analyze the success rate of these techniques in terms of bone gain and complications rate using titanium membranes as a barrier element. Electronic and hand searches were conducted in PubMed/Medline, Scielo, Scopus and Cochrane Library databases for case reports, case series, cohort studies and clinical trials in humans published up to and including 19 September 2020. Thirteen articles were included in the qualitative analysis. Bone gain both horizontally and vertically was comparable to that obtained with other types of membranes more commonly used. The postoperative complication rate was higher that of native collagen membranes and non-resorbable titanium-reinforced membranes, and similar that of crosslinked collagen membranes and titanium meshes. The survival rate of the implants was similar to that of implants placed in native bone. Due to the limited scientific literature published on this issue, more randomized clinical trials comparing occlusive titanium barriers and other types of membranes are necessary to reach more valid conclusions.
Collapse
Affiliation(s)
- Elisabet Roca-Millan
- Faculty of Medicine and Health Sciences (School of Dentistry), University of Barcelona, 08907 Barcelona, Spain;
| | - Enric Jané-Salas
- Oral Health and Masticatory System Group-IDIBELL, Faculty of Medicine and Health Sciences (School of Dentistry), Odontological Hospital University of Barcelona, University of Barcelona, 08907 Barcelona, Spain; (E.J.-S.); (A.E.-D.)
| | - Albert Estrugo-Devesa
- Oral Health and Masticatory System Group-IDIBELL, Faculty of Medicine and Health Sciences (School of Dentistry), Odontological Hospital University of Barcelona, University of Barcelona, 08907 Barcelona, Spain; (E.J.-S.); (A.E.-D.)
| | - José López-López
- Oral Health and Masticatory System Group-IDIBELL, Faculty of Medicine and Health Sciences (School of Dentistry), Odontological Hospital University of Barcelona, University of Barcelona, 08907 Barcelona, Spain; (E.J.-S.); (A.E.-D.)
- Correspondence: or
| |
Collapse
|
23
|
Antibacterial Bio-Based Polymers for Cranio-Maxillofacial Regeneration Applications. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10238371] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Cranio-maxillofacial structure is a region of particular interest in the field of regenerative medicine due to both its anatomical complexity and the numerous abnormalities affecting this area. However, this anatomical complexity is what makes possible the coexistence of different microbial ecosystems in the oral cavity and the maxillofacial region, contributing to the increased risk of bacterial infections. In this regard, different materials have been used for their application in this field. These materials can be obtained from natural and renewable feedstocks, or by synthetic routes with desired mechanical properties, biocompatibility and antimicrobial activity. Hence, in this review, we have focused on bio-based polymers which, by their own nature, by chemical modifications of their structure, or by their combination with other elements, provide a useful antibacterial activity as well as the suitable conditions for cranio-maxillofacial tissue regeneration. This approach has not been reviewed previously, and we have specifically arranged the content of this article according to the resulting material and its corresponding application; we review guided bone regeneration membranes, bone cements and devices and scaffolds for both soft and hard maxillofacial tissue regeneration, including hybrid scaffolds, dental implants, hydrogels and composites.
Collapse
|
24
|
Opris H, Bran S, Dinu C, Baciut M, Prodan DA, Mester A, Baciut G. Clinical applications of avian eggshell-derived hydroxyapatite. Bosn J Basic Med Sci 2020; 20:430-437. [PMID: 32651970 PMCID: PMC7664787 DOI: 10.17305/bjbms.2020.4888] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2020] [Accepted: 07/04/2020] [Indexed: 12/13/2022] Open
Abstract
The search for bone reconstruction materials and methods is an ongoing challenge. The aim of this review is to systemically search the available literature concerning the clinical performance of eggshell as a substitute material in guided bone regeneration in oral surgery. Five databases (PubMed, Cochrane, Web of Science, Scopus, and Embase) were searched up to February 2020. Clinical trials that used eggshell as a bone substitute material were included in the review. Animal and in vivo studies were excluded from the review. ROBINS-I was used to evaluate the risk of bias. A total of 840 studies were retrieved, out of which 55 full-text articles were screened. Five studies were finally included: one study showed critical and four serious risk of bias. A total of 74 patients and 88 intervention sites were included in the five studies. Clinical and radiological evaluation showed complete healing during the follow-ups. Statistically significant radiological and clinical evidence of new bone formation was achieved for socket preservation, grafting after third molar extraction, and cystic/apicectomy grafting. One patient with complications was reported. Histological analysis and micro computed tomography confirmed that it promotes bone regeneration. A comparison with synthetic hydroxyapatite showed similar healing characteristics. Within the limitations of the included studies, the eggshell can be safely and efficiently used in guided bone regeneration procedures, but more research is needed to completely evaluate the full potential of this material.
Collapse
Affiliation(s)
- Horia Opris
- Department of Maxillofacial Surgery and Implantology, "Iuliu Hatieganu" University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Simion Bran
- Department of Maxillofacial Surgery and Implantology, "Iuliu Hatieganu" University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Cristian Dinu
- Department of Maxillofacial Surgery and Implantology, "Iuliu Hatieganu" University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Mihaela Baciut
- Department of Maxillofacial Surgery and Implantology, "Iuliu Hatieganu" University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Daiana Antoaneta Prodan
- Department of Maxillofacial Surgery and Implantology, "Iuliu Hatieganu" University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Alexandru Mester
- Department of Oral Health, "Iuliu Hatieganu" University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Grigore Baciut
- Department of Maxillofacial Surgery and Implantology, "Iuliu Hatieganu" University of Medicine and Pharmacy, Cluj-Napoca, Romania
| |
Collapse
|
25
|
Aprile P, Letourneur D, Simon‐Yarza T. Membranes for Guided Bone Regeneration: A Road from Bench to Bedside. Adv Healthc Mater 2020; 9:e2000707. [PMID: 32864879 DOI: 10.1002/adhm.202000707] [Citation(s) in RCA: 80] [Impact Index Per Article: 20.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2020] [Revised: 07/28/2020] [Indexed: 12/14/2022]
Abstract
Bone resorption can negatively influence the osseointegration of dental implants. Barrier membranes for guided bone regeneration (GBR) are used to exclude nonosteogenic tissues from influencing the bone healing process. In addition to the existing barrier membranes available on the market, a growing variety of membranes for GBR with tailorable physicochemical properties are under preclinical evaluation. Hence, the aim of this review is to provide a comprehensive description of materials used for GBR and to report the main industrial and regulatory aspects allowing the commercialization of these medical devices (MDs). In particular, a summary of the main attributes defining a GBR membrane is reported along with a description of commercially available and under development membranes. Finally, strategies for the scaling-up of the manufacturing process and the regulatory framework of the main MD producers (USA, EU, Japan, China, and India) are presented. The description of the regulatory approval process of GBR membranes is representative of the typical path that medium- to high-risk MDs have to follow for an effective medical translation, which is of fundamental importance to increase the impact of biomedical research on public health.
Collapse
Affiliation(s)
- Paola Aprile
- LVTS INSERM U1148 X. Bichat Hospital Université de Paris Université Sorbonne Paris Nord Paris F‐75018 France
| | - Didier Letourneur
- LVTS INSERM U1148 X. Bichat Hospital Université de Paris Université Sorbonne Paris Nord Paris F‐75018 France
| | - Teresa Simon‐Yarza
- LVTS INSERM U1148 X. Bichat Hospital Université de Paris Université Sorbonne Paris Nord Paris F‐75018 France
| |
Collapse
|
26
|
Alain H, Christophe RB, Héléne LH, Fabienne W, Bénédicte E, Pierre L. Healing Process with the use of a New Resorbable Synthetic Membrane. Open Dent J 2020. [DOI: 10.2174/1874210602014010450] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Background:
Currently, absorbable membranes tend to be used most frequently for guided bone regeneration. They have many advantages and the most commonly reported complication is early exposure.
Objective:
This retrospective study reports the healing process of soft tissues over a four-week period using synthetic absorbable membranes.
Study Design:
One-hundred and ten cases were included. Soft tissue healing was assessed from anonymized photographs, in accordance with the criteria of the Early Healing Index (EHI) (Watchel et al., 2003). Cohen's Kappa (K) test was used to estimate the reliability of the measures and the variability between the examiners. Chi-squared test and Fisher’s exact test were used to assess the combination of healing outcomes with respect to the type of surgical intervention.
Results:
At 1-week, 81% of the cases showed a Primary Closure (PC) when the membrane was not initially exposed. The score increased to 98% at 4-weeks. Healing at 1-week varied significantly according to the type of intervention, with 73% of primary closure for bone augmentation during implantation, versus 60% for bone augmentation before implantation and 46% for alveolar preservation (Chi-square test, p = 0.049). No statistically significant differences in the healing process were observed between the smoking and non-smoking groups.
Conclusion:
This clinical study shows that the safety and exposure rates of this new synthetic membrane are comparable to the data gathered in the literature concerning non-cross-linked collagenous membranes.
Collapse
|
27
|
Peñarrocha-Oltra D, Soto-Peñaloza D, Peñarrocha-Diago M, Cervera-Ballester J, Cabanes-Gumbau G, Peñarrocha-Diago M. Hemostatic agents in endodontic surgery of maxillary molars: A randomized controlled pilot study of polytetrafluoroethylene (PTFE) strips as an adjunct to epinephrine impregnated gauze versus aluminum chloride. Med Oral Patol Oral Cir Bucal 2020; 25:e634-e643. [PMID: 32683388 PMCID: PMC7473427 DOI: 10.4317/medoral.23652] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2019] [Accepted: 06/04/2020] [Indexed: 11/13/2022] Open
Abstract
Background Hemostasis is of critical importance in endodontic surgery. Studies on bleeding control in maxillary molars are scarce. The present study compares the efficacy of two hemostatic techniques in controlling bleeding in endodontic surgery.
Material and Methods A randomized two-arm pilot study involving 30 patients with peri-radicular lesions in maxillary molars (first and second molars) was carried out including the following hemostatic agents: polytetrafluoroethylene (PTFE) strips as an adjunct to epinephrine impregnated gauze (test group; n = 15) and aluminum chloride (Expasyl™) (control; n = 15). Bleeding control was independently assessed by the surgeon and by two blinded observers before and after application of the hemostatic agent, and was classified as either adequate (complete bleeding control) or inadequate (incomplete bleeding control).
Results Bleeding control was similar in both groups. Simple binary logistic regression analysis failed to identify variables affecting bleeding control. Only the height of the keratinized mucosal band (≥ 2 mm) suggested a decreased risk of inadequate bleeding control of up to 89% (OR=0.11; p=0.06).
Conclusions No difference in the efficacy of bleeding control was observed between PTFE strips as an adjunct to epinephrine impregnated gauze and aluminum chloride in maxillary molars. Key words:PTFE-strips, aluminum chloride, endodontic surgery, epinephrine, hemostasis, hemostatic agent, molars.
Collapse
|
28
|
Janjić K, Schädl B, Andrukhov O, Agis H. The response of gingiva monolayer, spheroid, and ex vivo tissue cultures to collagen membranes and bone substitute. J Tissue Eng Regen Med 2020; 14:1307-1317. [PMID: 32652865 PMCID: PMC7539981 DOI: 10.1002/term.3102] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2020] [Revised: 06/26/2020] [Accepted: 07/03/2020] [Indexed: 12/11/2022]
Abstract
Collagen membranes and bone substitute are popular biomaterials in guided tissue regeneration for treatment of traumatized or diseased periodontal tissue. Development of these biomaterials starts in monolayer cell culture, failing to reflect in vivo tissue organization. Spheroid cultures potentially mimic in vivo tissues in structure and functionality. This study aims to compare gingiva cell (GC) monolayers and spheroids to ex vivo gingiva. Human GC monolayers, spheroids and gingiva ex vivo tissues were cultured on plastic surfaces, collagen membranes or bone substitute. Hematoxylin-eosin (HE) staining, immunohistochemistry for KI67 and caspase 3 (CASP3), resazurin-based toxicity assays, quantitative polymerase chain reaction for collagen I (COL1A1), vascular endothelial growth factor (VEGF), angiogenin (ANG), interleukin (IL)6 and IL8 and ELISA for COL1A1, VEGF, ANG, IL6 and IL8 were performed in all cultures. Morphology was different in all culture set-ups. Staining of KI67 was positive in monolayers and staining of CASP3 was positive in spheroids. All culture set-ups were viable. COL1A1 production was modulated in monolayers and ex vivo tissues at mRNA levels, VEGF in monolayers and ex vivo tissues at mRNA levels and in spheroids at protein levels, ANG in spheroids at mRNA levels and in monolayers and spheroids at protein levels, IL6 in monolayers and spheroids at mRNA levels and in spheroids and ex vivo tissues at protein levels and IL8 in monolayers and ex vivo tissues at mRNA levels. Modulations were surface-dependent. In conclusion, each culture model is structurally and functionally different. Neither GC monolayers nor spheroids mimicked gingiva ex vivo tissue in all measured aspects.
Collapse
Affiliation(s)
- Klara Janjić
- Department of Conservative Dentistry and Periodontology, University Clinic of DentistryMedical University of ViennaViennaAustria
- Austrian Cluster for Tissue RegenerationViennaAustria
| | - Barbara Schädl
- Department of Conservative Dentistry and Periodontology, University Clinic of DentistryMedical University of ViennaViennaAustria
- Austrian Cluster for Tissue RegenerationViennaAustria
- AUVA Research CenterLudwig Boltzmann Institute for Experimental and Clinical TraumatologyViennaAustria
| | - Oleh Andrukhov
- Department of Conservative Dentistry and Periodontology, University Clinic of DentistryMedical University of ViennaViennaAustria
| | - Hermann Agis
- Department of Conservative Dentistry and Periodontology, University Clinic of DentistryMedical University of ViennaViennaAustria
- Austrian Cluster for Tissue RegenerationViennaAustria
| |
Collapse
|
29
|
Schorn L, Handschel J, Lommen J, VON Beck FP, Depprich R, Kübler N, Holtmann H. Evaluation of Biocompatibility of Different Membrane Surfaces Using Unrestricted Somatic Stem Cells. In Vivo 2020; 33:1447-1454. [PMID: 31471391 DOI: 10.21873/invivo.11623] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2019] [Revised: 07/10/2019] [Accepted: 07/19/2019] [Indexed: 01/31/2023]
Abstract
BACKGROUND/AIM Results of Guided Bone Regeneration (GBR) primarily depend on the membrane used. The aim of this study was to compare biocompatibility of different absorbable and non-absorbable membranes by using unrestricted somatic stem cells (USSCs) as an indicator for biocompatibility. MATERIALS AND METHODS Five absorbable membranes (Bio-Gide®, RESODONT®, GENTA-FOIL resorb®, BioMend® and BioMend® Extend™) and one non-absorbable alternative (GORE-TEX®) were colonized with USSCs. After 24 h, 3 days and 7 days, cell proliferation, cell viability, and cytotoxicity were assessed. Moreover, cell morphology was evaluated by electron microscopy. RESULTS Significantly higher cell proliferation and cell viability rates were observed in Bio-Gide® and RESODONT® membranes. Cell toxicity was highest on GENTA-FOIL resorb® membranes. The electron microscopical assessment showed a better cell attachment on porous surfaced membranes. CONCLUSION This study shows that USSCs can be used for assessments of biocompatibility, and that absorbable membranes with collagenous composition and porous structure tend to positively impact biocompatibility and enhance cell proliferation.
Collapse
Affiliation(s)
- Lara Schorn
- Department of Oral-, Maxillo- and Plastic Facial Surgery, Heinrich-Heine-University and University Hospital Duesseldorf, Duesseldorf, Germany
| | - Jörg Handschel
- Klinik und Praxisgemeinschaft am Kaiserteich, Düsseldorf, Germany
| | - Julian Lommen
- Department of Oral-, Maxillo- and Plastic Facial Surgery, Heinrich-Heine-University and University Hospital Duesseldorf, Duesseldorf, Germany
| | - Felix Paulssen VON Beck
- Department of Oral-, Maxillo- and Plastic Facial Surgery, Malteser Krankenhaus, St. Josefshospital Uerdingen, Krefeld-Uerdingen, Germany
| | - Rita Depprich
- Department of Oral-, Maxillo- and Plastic Facial Surgery, Heinrich-Heine-University and University Hospital Duesseldorf, Duesseldorf, Germany
| | - Norbert Kübler
- Department of Oral-, Maxillo- and Plastic Facial Surgery, Heinrich-Heine-University and University Hospital Duesseldorf, Duesseldorf, Germany
| | - Henrik Holtmann
- Department of Oral-, Maxillo- and Plastic Facial Surgery, Malteser Krankenhaus St. Johannes-Stift, Duisburg, Germany
| |
Collapse
|
30
|
Korzinskas T, Jung O, Smeets R, Stojanovic S, Najman S, Glenske K, Hahn M, Wenisch S, Schnettler R, Barbeck M. In Vivo Analysis of the Biocompatibility and Macrophage Response of a Non-Resorbable PTFE Membrane for Guided Bone Regeneration. Int J Mol Sci 2018; 19:E2952. [PMID: 30262765 PMCID: PMC6213856 DOI: 10.3390/ijms19102952] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2018] [Revised: 09/19/2018] [Accepted: 09/25/2018] [Indexed: 01/12/2023] Open
Abstract
The use of non-resorbable polytetrafluoroethylene (PTFE) membranes is indicated for the treatment of large, non-self-containing bone defects, or multi-walled defects in the case of vertical augmentations. However, less is known about the molecular basis of the foreign body response to PTFE membranes. In the present study, the inflammatory tissue responses to a novel high-density PTFE (dPTFE) barrier membrane have preclinically been evaluated using the subcutaneous implantation model in BALB/c mice by means of histopathological and histomorphometrical analysis methods and immunohistochemical detection of M1- and M2-macrophages. A collagen membrane was used as the control material. The results of the present study demonstrate that the tissue response to the dPTFE membrane involves inflammatory macrophages, but comparable cell numbers were also detected in the implant beds of the control collagen membrane, which is known to be biocompatible. Although these data indicate that the analyzed dPTFE membrane is not fully bioinert, but its biocompatibility is comparable to collagen-based membranes. Based on its optimal biocompatibility, the novel dPTFE barrier membrane may optimally support bone healing within the context of guided bone regeneration (GBR).
Collapse
Affiliation(s)
- Tadas Korzinskas
- Section for Regenerative Orofacial Medicine, Department of Oral and Maxillofacial Surgery, University Hospital Hamburg-Eppendorf, 20246 Hamburg, Germany.
| | - Ole Jung
- Section for Regenerative Orofacial Medicine, Department of Oral and Maxillofacial Surgery, University Hospital Hamburg-Eppendorf, 20246 Hamburg, Germany.
| | - Ralf Smeets
- Section for Regenerative Orofacial Medicine, Department of Oral and Maxillofacial Surgery, University Hospital Hamburg-Eppendorf, 20246 Hamburg, Germany.
| | - Sanja Stojanovic
- Institute of Biology and Human Genetics, Department for Cell and Tissue Engineering, University of Niš, Faculty of Medicine, 18106 Niš, Serbia.
| | - Stevo Najman
- Institute of Biology and Human Genetics, Department for Cell and Tissue Engineering, University of Niš, Faculty of Medicine, 18106 Niš, Serbia.
| | - Kristina Glenske
- Clinic of Small Animals, c/o Institute of Veterinary Anatomy, Histology and Embryology, Justus Liebig University of Giessen, 35390 Giessen, Germany.
| | - Michael Hahn
- Department of Osteology and Biomechanics, University Hospital Hamburg-Eppendorf, 20246 Hamburg, Germany.
| | - Sabine Wenisch
- Clinic of Small Animals, c/o Institute of Veterinary Anatomy, Histology and Embryology, Justus Liebig University of Giessen, 35390 Giessen, Germany.
| | - Reinhard Schnettler
- University Medical Center, Justus Liebig University of Giessen, 35390 Giessen, Germany.
| | - Mike Barbeck
- Section for Regenerative Orofacial Medicine, Department of Oral and Maxillofacial Surgery, University Hospital Hamburg-Eppendorf, 20246 Hamburg, Germany.
- BerlinAnalytix GmbH, 12109 Berlin, Germany.
| |
Collapse
|
31
|
Abstract
Silk derived from the silkworm is known for its excellent biological and mechanical properties. It has been used in various fields as a biomaterial, especially in bone tissue engineering scaffolding. Recently, silk protein-based biomaterial has been used as a barrier membrane scaffolding for guided bone regeneration (GBR). GBR promotes bone regeneration in bone defect areas using special barrier membranes. GBR membranes should have biocompatibility, biodegradability, cell occlusion, the mechanical properties of space-making, and easy clinical handling. Silk-based biomaterial has excellent biologic and mechanical properties that make it a good candidate to be used as GBR membranes. Recently, various forms of silk protein-based membranes have been introduced, demonstrating excellent bone regeneration ability, including osteogenic cell proliferation and osteogenic gene expression, and promoting new bone regeneration in vivo. In this article, we introduced the characteristics of silk protein as bone tissue engineering scaffolding and the recent application of such silk material as a GBR membrane. We also suggested future studies exploring additional uses of silk-based materials as GBR membranes.
Collapse
|