1
|
Fu M, Ye Y, Pu R, Zhu D, Yang G, Jiang Z. Patient and implant-related risk factors for implant failure of one-stage lateral sinus floor elevation: A 2- to 10-year retrospective study. Clin Implant Dent Relat Res 2024. [PMID: 39219251 DOI: 10.1111/cid.13380] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2024] [Revised: 07/24/2024] [Accepted: 08/02/2024] [Indexed: 09/04/2024]
Abstract
OBJECTIVES This retrospective study aimed to evaluate the early and late implant failure rates of one-stage lateral sinus floor elevation (LSFE) and to identify the patient and implant-related risk factors associated with these failures. MATERIALS AND METHODS All patients treated with one-stage LSFE from January 2014 to December 2021 were evaluated for inclusion. A total of 618 patients with 936 implants met the inclusion criteria. Clinical and radiographic information about patient and implants was collected. Univariate and multivariate Cox proportional hazards frailty regression models were performed to identify risk factors for early and late implant failure. RESULTS The cumulative implant survival rate was 95.62% (95% CI 93.90%-97.68%), with 16 early implant failures and 25 late implant failures. The Cox analysis indicated that ≤3 mm residual bone height (RBH) was associated with a higher early failure rate. For late implant failure, smoking habit, ≤3 mm RBH, and certain implant brand were independent risk factors. Narrow sinus ostium, long infundibulum, and flat thickening of Schneiderian membrane might be non-independent risk factors for late implant failure. No significance was found in other variables, including age, periodontitis history, implant characteristics (position, diameter, length, protrusion length, marginal bone loss), surgeon experience, healing time, opposing dentition, and prosthesis. CONCLUSIONS One-stage LSFE is a predictable treatment for patients with atrophic maxilla. ≤3 mm RBH increased the risk of early implant failure, while smoking habit, ≤3 mm RBH, and certain implant brand were independent risk factors for late implant failure.
Collapse
Affiliation(s)
- Mengdie Fu
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, China
| | - Yuer Ye
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, China
| | - Rui Pu
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, China
| | - Danji Zhu
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, China
| | - Guoli Yang
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, China
| | - Zhiwei Jiang
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, China
| |
Collapse
|
2
|
Wu HC, Huang HL, Fuh LJ, Tsai MT, Hsu JT. Influence of implant length and insertion depth on primary stability of short dental implants: An in vitro study of a novel mandibular artificial bone model. J Dent Sci 2024; 19:139-147. [PMID: 38303865 PMCID: PMC10829676 DOI: 10.1016/j.jds.2023.05.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Revised: 05/16/2023] [Indexed: 02/03/2024] Open
Abstract
Background/purpose Dental implants are a mainstream solution for missing teeth. For the improvement of dental implant surface treatment and design, short dental implants have become an alternative to various complex bone augmentation procedures, especially those performed at the posterior region of both the maxilla and mandible. The objective of this study was to evaluate the effect of various insertion methods on the primary stability of short dental implants. Materials and methods Commercial dental implants were inserted into artificial mandibular bone specimens using various insertion methods (equicrestal position, subcrestal position 1.5 mm, and lateral cortical anchorage) in accordance with an implant surgical guide. Insertion torque value (ITV) curves were recorded while implant procedures were performed. Both maximum ITVs (MITVs) and final ITVs (FITVs) were evaluated. Subsequently, Periotest values (PTVs) and implant stability quotients (ISQs) were measured for all specimens. A Kruskal-Wallis test was conducted to analyze the results for four primary stability parameters, and the Dunn test was used for a post hoc pairwise comparison when a difference was identified. Results For all groups, their mean MITVs ranged from 33.6 to 59.4 N cm, whereas their mean FITVs ranged from 17.5 to 43.5 N cm. Insertion torque value, ISQ, and PTV decreased significantly when implants were inserted into subcrestal positions. When implants were inserted in the lateral bicortical position, the four aforementioned parameters yielded greater values. Conclusion When 6-mm short implants were inserted in a lateral cortical anchorage position, high primary stability was yielded.
Collapse
Affiliation(s)
- Hsiang-Chun Wu
- School of Dentistry, China Medical University, Taichung, Taiwan
| | - Heng-Li Huang
- School of Dentistry, China Medical University, Taichung, Taiwan
- Department of Bioinformatics and Medical Engineering, Asia University, Taichung, Taiwan
- Department of Biomedical Engineering, China Medical University, Taichung, Taiwan
| | - Lih-Jyh Fuh
- School of Dentistry, China Medical University, Taichung, Taiwan
- Department of Dentistry, China Medical University and Hospital, Taichung, Taiwan
| | - Ming-Tzu Tsai
- Department of Biomedical Engineering, Hungkuang University, Taichung, Taiwan
| | - Jui-Ting Hsu
- School of Dentistry, China Medical University, Taichung, Taiwan
- Department of Biomedical Engineering, China Medical University, Taichung, Taiwan
| |
Collapse
|
3
|
Wang Z, Zhang J, Li N, Pu R, Wang Y, Yang G. Survival analysis of implants placed simultaneously with lateral sinus floor elevation in severely atrophic maxilla: A 3- to 12-year retrospective cohort study. Clin Implant Dent Relat Res 2023; 25:1069-1079. [PMID: 37442813 DOI: 10.1111/cid.13249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Revised: 06/21/2023] [Accepted: 07/06/2023] [Indexed: 07/15/2023]
Abstract
OBJECTIVES To retrospectively evaluate whether implants placed simultaneously with lateral sinus floor elevation (LSFE) in severely atrophic maxilla (residual bone height [RBH] ≤3 mm) could achieve long-term survival and comprehensively analyze the factors influencing their survival rates. MATERIALS AND METHODS A total of 123 patients receiving LSFE and simultaneous implant placement from 2010 to 2019 and their 123 implants in sites with RBH ≤3 mm were included in this study. Basic characteristics of patients and implants were collected from the medical record system and cone-beam computed tomography (CBCT) images. Kaplan-Meier survival curves were applied to estimate cumulative survival rates (CSRs) and Cox proportional hazards regression models were used to detect factors influencing implant survival. RESULTS The 6-year and 12-year CSR of implants placed in sites with RBH ≤3 mm were 95.7% (95% confidence interval [CI]: 92.1%-99.5%) and 76.6% (95% CI: 58.1%-100%), respectively. Eight patients presented late implant failure. Univariate and multivariate Cox regression analyses demonstrated that RBH ≤2 mm (hazard ratio [HR]: 20.63, p = 0.000) and smoking habit (HR: 6.055, p = 0.024) were significantly associated with long-term implant survival. Specifically, the 10-year CSR of implants in sites with RBH ≤2 mm (53.3%, 95% CI: 27.5%-100%) was dramatically lower than those in sites with RBH >2 mm (92.9%, 95% CI: 81.7%-100%, p = 0.000). CONCLUSIONS Implants placed simultaneously with LSFE in sites with RBH ≤3 mm can achieve long-term survival. However, caution is required especially for implantation in sites with RBH ≤2 mm. Besides, the smoking habit is also considered a risk factor jeopardizing long-term implant survival.
Collapse
Affiliation(s)
- Zhikang Wang
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, People's Republic of China
| | - Jing Zhang
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, People's Republic of China
| | - Na Li
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, People's Republic of China
| | - Rui Pu
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, People's Republic of China
| | - Ying Wang
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, People's Republic of China
| | - Guoli Yang
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, People's Republic of China
| |
Collapse
|
4
|
Primary Stability of Conventionally Tapered Versus Reverse Tapered Body Shift Implants Under Varying Bone Support Conditions—An In-Vitro Study. J Med Biol Eng 2022. [DOI: 10.1007/s40846-022-00736-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
5
|
Tumedei M, Piattelli A, Falco A, De Angelis F, Lorusso F, Di Carmine M, Iezzi G. An in vitro evaluation on polyurethane foam sheets of the insertion torque, removal torque values, and resonance frequency analysis (RFA) of a self-tapping threads and round apex implant. CELLULAR POLYMERS 2020. [DOI: 10.1177/0262489320971796] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
The dental implant primary stability and micromovement absence represent critical factor for dental implant osseointegration. The aim of the present in vitro investigation was to simulate the bone response on different polyurethane densities the effect of self-tapping threads and round apex implant geometry. A total of 40 implants were positioned in D1, D2, D3 and D4 polyurethane block densities following a calibrated drilling protocol. The Insertion, removal Torque and resonance frequency analysis (RFA) means were calculated. All experimental conditions showed insertion torque values >30 Ncm. A significant higher insertion torque, removal and RFA was present in D1 polyurethane. Similar evidences were evidenced for D3 and D4. The effectiveness of the present study suggested a valuable clinical advantage for self-tapping threads and round apex implant using, such as in case of reduced bone density in the posterior maxilla
Collapse
Affiliation(s)
- Margherita Tumedei
- Department of Medical, Oral and Biotechnological Sciences, University of Chieti-Pescara, Via dei Vestini, Chieti, Italy
| | - Adriano Piattelli
- Department of Medical, Oral and Biotechnological Sciences, University of Chieti-Pescara, Via dei Vestini, Chieti, Italy
- Chair of Biomaterials Engineering, Catholic University of San Antonio de Murcia (UCAM), Av. de los Jerónimos, Guadalupe, Murcia, Spain
- Fondazione Villa Serena per la Ricerca, Città Sant’Angelo (PE), Italy
| | | | - Francesco De Angelis
- Department of Medical, Oral and Biotechnological Sciences, University of Chieti-Pescara, Via dei Vestini, Chieti, Italy
| | - Felice Lorusso
- Department of Medical, Oral and Biotechnological Sciences, University of Chieti-Pescara, Via dei Vestini, Chieti, Italy
| | | | - Giovanna Iezzi
- Department of Medical, Oral and Biotechnological Sciences, University of Chieti-Pescara, Via dei Vestini, Chieti, Italy
| |
Collapse
|
6
|
Christiaens V, Pitman J, Glibert M, Hommez G, Atashkadeh M, De Bruyn H. Rationale for a reverse tapered body shift implant for immediate placement. Int J Oral Maxillofac Surg 2020; 49:1630-1636. [PMID: 32371178 DOI: 10.1016/j.ijom.2020.04.007] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2019] [Revised: 02/18/2020] [Accepted: 04/09/2020] [Indexed: 11/24/2022]
Abstract
Immediate implant placement holds considerable value, yet primary implant stability is often a critical factor. The aim of this study was to evaluate the stability, volumetric viability, and buccal gap size of reverse tapered body shift (RTBS) implants after immediate placement. Peak insertion torque measurements of two RTBS designs (apical 40% vs. apical 50%), relative to conventionally tapered implants, were assessed in simulated extraction sockets prepared in synthetic bone blocks. Additionally, the proximity of the RTBS implants to neighbouring teeth and anatomical structures, and the buccal gap distance were evaluated in human cadavers. The mean (± standard deviation) insertion torque was 12.00±1.40N•cm for the conventionally tapered implants (n=50), 35.36±2.74N•cm (n=50) for RTBS-1, and 48.20±2.90N•cm (n=50) for RTBS-2; the difference between designs was statistically significant (P<0.01). In total, 40 RTBS implants (20 per design) were placed in six cadaveric premaxillae. Only one locus was inappropriate for both RTBS implant designs, due to the proximity of neighbouring teeth. The average buccal gap for both implant designs was 2.8mm (P=0.104). The improved primary stability and increased buccal gap size with RTBS implants may enhance the feasibility of immediate placement. The study findings should be further validated in clinical trials.
Collapse
Affiliation(s)
- V Christiaens
- Faculty of Medicine and Health Sciences, Dental School, Department of Periodontology and Oral Implantology, Ghent University, Ghent, Belgium.
| | - J Pitman
- Southern Implants (Pty), Ltd, Irene, Gauteng, South Africa
| | - M Glibert
- Faculty of Medicine and Health Sciences, Dental School, Department of Periodontology and Oral Implantology, Ghent University, Ghent, Belgium
| | - G Hommez
- Faculty of Medicine and Health Sciences, Dental School, Department of Periodontology and Oral Implantology, Ghent University, Ghent, Belgium
| | - M Atashkadeh
- Periodontology and Oral Implantology, All Saints Green Dental Practice, Norwich, UK
| | - H De Bruyn
- Faculty of Medicine and Health Sciences, Dental School, Department of Periodontology and Oral Implantology, Ghent University, Ghent, Belgium; Radboud University Medical Centre, Radboud Institute - Health Sciences, Department of Dentistry, Implantology and Periodontology, Nijmegen, The Netherlands
| |
Collapse
|
7
|
Lee J, Pyo SW, Cho HJ, An JS, Lee JH, Koo KT, Lee YM. Comparison of implant stability measurements between a resonance frequency analysis device and a modified damping capacity analysis device: an in vitro study. J Periodontal Implant Sci 2020; 50:56-66. [PMID: 32128274 PMCID: PMC7040444 DOI: 10.5051/jpis.2020.50.1.56] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2019] [Revised: 01/08/2020] [Accepted: 02/14/2020] [Indexed: 11/13/2022] Open
Abstract
Purpose A stability-measuring device that utilizes damping capacity analysis (DCA) has recently been introduced in the field of dental implantology. This study aimed to evaluate the sensitivity and reliability of this device by measuring the implant stability of ex vivo samples in comparison with a resonance frequency analysis (RFA) device. Methods Six implant beds were prepared in porcine ribs using 3 different drilling protocols to simulate various implant stability conditions. Thirty-six pork ribs and 216 bone-level implants measuring 10 mm in height were used. The implant beds were prepared using 1 of the following 3 drilling protocols: 10-mm drilling depth with a 3.5-mm-diameter twist drill, 5-mm drilling depth with a 4.0-mm-diameter twist drill, and 10-mm drilling depth with a 4.0-mm-diameter twist drill. The first 108 implants were external-connection implants 4.0 mm in diameter, while the other 108 implants were internal-connection implants 4.3 mm in diameter. The peak insertion torque (PIT) during implant placement, the stability values obtained with DCA and RFA devices after implant placement, and the peak removal torque (PRT) during implant removal were measured. Results The intraclass correlation coefficients (ICCs) of the implant stability quotient (ISQ) results obtained using the RFA device at the medial, distal, ventral, and dorsal points were 0.997, 0.994, 0.994, and 0.998, respectively. The ICCs of the implant stability test (IST) results obtained using the DCA device at the corresponding locations were 0.972, 0.975, 0.974, and 0.976, respectively. Logarithmic relationships between PIT and IST, PIT and ISQ, PRT and IST, and PRT and ISQ were observed. The mean absolute difference between the ISQ and IST values on a Bland-Altman plot was −6.76 (−25.05 to 11.53, P<0.05). Conclusions Within the limits of ex vivo studies, measurements made using the RFA and DCA devices were found to be correlated under a variety of stability conditions.
Collapse
Affiliation(s)
- Jungwon Lee
- Department of Periodontics, One-Stop Specialty Center, Seoul National University Dental Hospital, Seoul, Korea
| | - Se-Wook Pyo
- Department of Dentistry, Ajou University School of Medicine, Suwon, Korea
| | - Hyun-Jae Cho
- Department of Preventive Dentistry & Public Oral Health, Seoul National University School of Dentistry, Seoul, Korea
| | - Jung-Sub An
- Department of Orthodontics, Seoul National University Dental Hospital, Seoul, Korea
| | - Jae-Hyun Lee
- Department of Prosthodontics, One-Stop Specialty Center, Seoul National University Dental Hospital, Seoul, Korea
| | - Ki-Tae Koo
- Department of Periodontology and Dental Research Institute, Seoul National University School of Dentistry, Seoul, Korea
| | - Yong-Moo Lee
- Department of Periodontology and Dental Research Institute, Seoul National University School of Dentistry, Seoul, Korea
| |
Collapse
|
8
|
Abi-Aad HL, Daher FI, Baba NZ, Cordioli G, Majzoub ZAK. Insertion Torque of Variable-Thread Tapered Implants in the Posterior Maxilla: A Clinical Study. J Prosthodont 2018; 28:e788-e794. [PMID: 30178903 DOI: 10.1111/jopr.12965] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/13/2018] [Indexed: 11/30/2022] Open
Abstract
PURPOSE Primary stability is a key factor for successful implant osseointegration, especially in poor bone quality and early/immediate loading. In the immediate loading protocol, insertion torque values (ITVs) have been suggested to be the most valid prognostic factor for osseointegration of maxillary implants. The objectives of this study were to: (1) evaluate ITVs achieved by a variable-thread tapered implant in the posterior maxilla; and (2) assess the impact of bone quality, implant dimensions, bicortical anchorage, and implant location on ITVs. MATERIALS AND METHODS Twenty-six adult, systemically healthy patients received 173 variable-thread tapered implants in maxillary premolar and molar healed edentulous sites with a minimum subsinus height of 8 mm. Implant sites were prepared using the bone-quality adjusted drilling sequence according to manufacturer's recommendations. Bone quality was recorded subjectively during drilling based on Misch criteria (D1-D4), and ITVs were measured with a manual torque wrench. Univariate and multivariate analyses were performed at the 0.05 significance level. RESULTS First and second molar sites accounted for 46.8% of all implants. D4 bone was encountered in 61.3% of the sites. Most of the implants were 4.3 mm in diameter (59.5%), and lengths of 11.5 and 13 mm were most commonly used (75.2%). Approximately half of the implants were associated with apical cortical anchorage (51.4%). The overall mean ITV was 44.5 ± 23.0 Ncm, with 65.5 ± 15.6 Ncm, 55.5 ± 19.6 Ncm, and 36.6 ± 21.7 Ncm for D2, D3, and D4 bone, respectively. Bone quality and implant location significantly affected ITVs, while implant dimensions and apical cortical anchorage did not. CONCLUSIONS ITVs of variable-thread implants were significantly influenced by variations in bone quality and implant position in the posterior maxilla. Despite the influence of bone quality on primary stability, the mean ITVs attained with variable-thread tapered implants in poor bone quality were within the recommended range for immediate loading.
Collapse
Affiliation(s)
- Habib L Abi-Aad
- Department of Prosthodontics, Faculty of Dental Medicine, Lebanese University, Hadath, Lebanon
| | - Fadi I Daher
- Department of Periodontics, Faculty of Dental Medicine, Lebanese University, Hadath, Lebanon
| | - Nadim Z Baba
- Advanced Specialty Education Program in Prosthodontics, School of Dentistry, Loma Linda University
| | | | - Zeina A K Majzoub
- Department of Periodontics, Faculty of Dental Medicine, Lebanese University, Hadath, Lebanon
| |
Collapse
|
9
|
Buyukguclu G, Ozkurt-Kayahan Z, Kazazoglu E. Reliability of the Osstell Implant Stability Quotient and Penguin Resonance Frequency Analysis to Evaluate Implant Stability. IMPLANT DENT 2018; 27:429-433. [DOI: 10.1097/id.0000000000000766] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
10
|
Bite Reconstruction in the Aesthetic Zone Using One-Piece Bicortical Screw Implants. Case Rep Dent 2018; 2018:4671482. [PMID: 29854483 PMCID: PMC5949185 DOI: 10.1155/2018/4671482] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2017] [Revised: 02/11/2018] [Accepted: 03/11/2018] [Indexed: 11/28/2022] Open
Abstract
The aim of this article was to present the clinical application of a new, smooth surfaced one-piece bicortical screw implant with immediate loading protocol. An 18-year-old, healthy male patient with a history of total dislocation and replantation of teeth 11 and 21 in early childhood was admitted to the clinic. Teeth 11 and 21 were extracted, and two long one-piece implants were inserted at extraction sockets in one surgical session under local anesthesia. Temporary composite crowns were placed in the patient on the same day. After 3 months, the single-phase two-layer impression was made and the composite crowns were replaced with metal-ceramic crowns. After 12 months, satisfactory aesthetic and functional results were obtained.
Collapse
|
11
|
Arosio P, Greco GB, Zaniol T, Iezzi G, Perrotti V, Di Stefano DA. Sinus augmentation and concomitant implant placement in low bone-density sites. A retrospective study on an undersized drilling protocol and primary stability. Clin Implant Dent Relat Res 2017; 20:151-159. [PMID: 29164788 DOI: 10.1111/cid.12558] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2017] [Revised: 09/27/2017] [Accepted: 10/29/2017] [Indexed: 11/28/2022]
Abstract
BACKGROUND Recently, a torque-measuring micromotor has been shown to provide a reliable, quantitative intraoperative evaluation of bone density and implant primary stability. This may be particularly useful for determining bone quality of residual bone and consequently the most appropriate site preparation in the posterior maxilla, where bone often is of low density and quality. PURPOSE This work aimed to assess the medium-term success of implants placed during 1-stage sinus augmentations using an undersized drilling protocol. In case of low bone density, the relationship between residual bone height (RBH) and primary stability was also investigated. MATERIALS AND METHODS Clinical records of patients who underwent sinus augmentation and concomitant implant placement following a 12.5% undersized drilling protocol were retrospectively analyzed. In all patients, bone density measured intraoperatively was ≤ 0.45 g/cm3 . A minimum of 60 months of follow-up was required for inclusion. RESULTS Records of 106 patients who received 253 implants were reviewed. No significant difference in the implant success rate was found for patients who had less than 4 mm of RBH and those who had more. CONCLUSIONS Underpreparation of the implant-placement sites enabled achievement of successful implant-supported rehabilitation of the posterior maxilla even when both RBH and bone density were low.
Collapse
Affiliation(s)
| | | | | | - Giovanna Iezzi
- Department of Medical, Oral and Biotechnological Sciences, University of Chieti-Pescara, Chieti, Italy
| | - Vittoria Perrotti
- Department of Medical, Oral and Biotechnological Sciences, University of Chieti-Pescara, Chieti, Italy
| | | |
Collapse
|