1
|
Zhong J, Kamp N, Bansal A, Kumar A, Puri R, Krishnaswamy A, Kapadia S, Reed GW. Balloon Aortic Valvuloplasty in the Modern Era: A Review of Outcomes, Indications, and Technical Advances. JOURNAL OF THE SOCIETY FOR CARDIOVASCULAR ANGIOGRAPHY & INTERVENTIONS 2023; 2:101002. [PMID: 39131636 PMCID: PMC11307741 DOI: 10.1016/j.jscai.2023.101002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/01/2023] [Revised: 04/15/2023] [Accepted: 04/18/2023] [Indexed: 08/13/2024]
Abstract
Balloon aortic valvuloplasty (BAV) improves the hemodynamics and symptoms of patients with severe aortic stenosis in the short term with low rates of complications, but has not been shown to be an effective destination therapy. Our pooled analysis of >14,300 patients from studies published between January 1, 1991, and April 31, 2022, reported intraprocedural mortality and in-hospital mortality rates as 1.94% (95% CI, 1.39%-2.59%) and 6.02% (95% CI, 4.83%-7.32%), respectively. Hence, BAV is primarily indicated as a bridge to aortic valve replacement/decision with secondary uses as bridge to noncardiac surgery and palliative therapy. Recent advancements in alternative access sites, balloon catheters, and lithotripsy for BAV have opened opportunities for expanded use and further improvements in complication rates. As the utilization of BAV has continually increased since the advent of transcatheter aortic valve replacement, reexamining the role and outcomes of BAV in the era of transcatheter aortic valve replacement has become increasingly important. This review focuses on the outcomes, indications, advances, and technical considerations for BAV.
Collapse
Affiliation(s)
- Jeffrey Zhong
- Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio
| | - Nicholas Kamp
- Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio
| | - Agam Bansal
- Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio
| | - Ani Kumar
- Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio
| | - Rishi Puri
- Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio
| | - Amar Krishnaswamy
- Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio
| | - Samir Kapadia
- Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio
| | - Grant W. Reed
- Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio
| |
Collapse
|
2
|
Tsukui Y, Kitahara Y, Hasegawa Y, Kobayashi M, Osuka S, Iwase A. Anti-Müllerian hormone levels in the diagnosis of adolescent polycystic ovarian syndrome: a systematic review and meta-analysis. Endocr J 2022; 69:897-906. [PMID: 35675999 DOI: 10.1507/endocrj.ej22-0081] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Polycystic ovary syndrome (PCOS) is an endocrine disorder that causes menstrual cycle irregularities and infertility. PCOS is diagnosed based on hyperandrogenism, polycystic ovarian morphology (PCOM), and an-/oligo-ovulation. Upregulation of anti-Müllerian hormone (AMH) in the serum of women with PCOS may be another suitable alternative diagnostic criterion for PCOM. However, previous meta-analyses have reported conflicting results due to the age-dependent decline in serum AMH levels. Therefore, we performed a meta-analysis to evaluate the threshold of AMH for the diagnosis of PCOS in adolescents and women in their early twenties. Fifteen trials were included in this meta-analysis. PCOS is diagnosed with either Rotterdam criteria, NIH, or AE-PCOS. AMH levels were significantly higher in adolescents with PCOS (weighted mean difference, 3.05; 95% confidence interval: 2.09-4.01) than in the control group. The cutoff values of AMH for the diagnosis of adolescent PCOS were 6.1, 6.26, 7.03, 7.11, 7.2, and 7.25 ng/mL in the studies that reported the usefulness of AMH levels. The summary receiver operating characteristic analysis of the diagnostic accuracy demonstrated that the specificity and sensitivity were 81% and 66.3%, respectively. Our meta-analysis demonstrates that AMH may be a useful diagnostic test for adolescent PCOS and, based on the previous studies included in the meta-analysis, its cutoff value was estimated to be 6-7 ng/mL.
Collapse
Affiliation(s)
- Yumiko Tsukui
- Department of Obstetrics and Gynecology, Gunma University Graduate School of Medicine, Maebashi 371-8511, Japan
| | - Yoshikazu Kitahara
- Department of Obstetrics and Gynecology, Gunma University Graduate School of Medicine, Maebashi 371-8511, Japan
| | - Yuko Hasegawa
- Department of Obstetrics and Gynecology, Gunma University Graduate School of Medicine, Maebashi 371-8511, Japan
| | - Mio Kobayashi
- Department of Obstetrics and Gynecology, Gunma University Graduate School of Medicine, Maebashi 371-8511, Japan
| | - Satoko Osuka
- Department of Obstetrics and Gynecology, Nagoya University Graduate School of Medicine, Nagoya 466-8550, Japan
| | - Akira Iwase
- Department of Obstetrics and Gynecology, Gunma University Graduate School of Medicine, Maebashi 371-8511, Japan
| |
Collapse
|
3
|
Yuzawa-Tsukada N, Kashiwagi Y, Nonoue A, Uno G, Fujii S, Murakami A, Ogawa K, Kawai M, Muto M, Yoshimura M, Miyamoto T. The safety and feasibility of retrograde balloon aortic valvuloplasty using the INOUE-BALLOON with severe aortic stenosis. Heart Vessels 2022; 37:2093-2100. [PMID: 35842560 DOI: 10.1007/s00380-022-02120-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2021] [Accepted: 06/15/2022] [Indexed: 11/04/2022]
Abstract
In the transcatheter aortic valve implantation (TAVI) era, the indications for balloon aortic valvuloplasty (BAV) are increasing. Previously, the INOUE-BALLOON® (IB) was used only for antegrade BAV, but recently, it has also been used for retrograde BAV. However, the safety and feasibility of retrograde BAV using an IB are not fully understood. In this study, we investigated the safety and feasibility of retrograde BAV using an IB in elderly Japanese patients with severe aortic stenosis (AS). We compared 39 cases of retrograde BAV using an IB performed from June 2018 to September 2020 and 34 cases of antegrade BAV using an IB performed from August 2013 to May 2018. The total number of complications was lower in retrograde BAV than in antegrade BAV (p = 0.020). The procedure time was significantly shorter in retrograde BAV than in antegrade BAV (p < 0.001), and the maximum balloon size and number of balloon inflations were smaller in retrograde BAV than in antegrade BAV (p = 0.002 and p < 0.001, respectively). There was no significant difference in the degree of improvement in the aortic valve area or ejection fraction between retrograde and antegrade BAV. In conclusion, the present study showed the safety and feasibility of retrograde BAV using an IB in elderly Japanese patients with severe AS compared with antegrade BAV using an IB.
Collapse
Affiliation(s)
- Naoko Yuzawa-Tsukada
- Division of Cardiology, Department of Internal Medicine, The Jikei University Katsushika Medical Center, 6-41-2 Aoto, Katsushika-ku, Tokyo, 125-8506, Japan. .,Division of Cardiology, Saitama Cardiovascular and Respiratory Center, Kumagaya, Saitama, Japan.
| | - Yusuke Kashiwagi
- Division of Cardiology, Department of Internal Medicine, The Jikei University School of Medicine, Tokyo, Japan
| | - Akira Nonoue
- Division of Cardiology, Saitama Cardiovascular and Respiratory Center, Kumagaya, Saitama, Japan.,Division of Cardiology, Department of Internal Medicine, The Jikei University School of Medicine, Tokyo, Japan
| | - Goki Uno
- Division of Cardiology, Saitama Cardiovascular and Respiratory Center, Kumagaya, Saitama, Japan.,Division of Cardiology, Department of Internal Medicine, The Jikei University School of Medicine, Tokyo, Japan
| | - Shinya Fujii
- Division of Cardiology, Saitama Cardiovascular and Respiratory Center, Kumagaya, Saitama, Japan.,Division of Cardiology, Department of Internal Medicine, The Jikei University School of Medicine, Tokyo, Japan
| | - Akimichi Murakami
- Division of Cardiology, Saitama Cardiovascular and Respiratory Center, Kumagaya, Saitama, Japan
| | - Kazuo Ogawa
- Division of Cardiology, Department of Internal Medicine, The Jikei University School of Medicine, Tokyo, Japan
| | - Makoto Kawai
- Division of Cardiology, Department of Internal Medicine, The Jikei University School of Medicine, Tokyo, Japan
| | - Makoto Muto
- Division of Cardiology, Saitama Cardiovascular and Respiratory Center, Kumagaya, Saitama, Japan.,Division of Cardiology, Department of Internal Medicine, The Jikei University School of Medicine, Tokyo, Japan
| | - Michihiro Yoshimura
- Division of Cardiology, Department of Internal Medicine, The Jikei University School of Medicine, Tokyo, Japan
| | - Takashi Miyamoto
- Division of Cardiology, Saitama Cardiovascular and Respiratory Center, Kumagaya, Saitama, Japan
| |
Collapse
|
4
|
Kleczynski P, Kulbat A, Brzychczy P, Dziewierz A, Trebacz J, Stapor M, Sorysz D, Rzeszutko L, Bartus S, Dudek D, Legutko J. Balloon Aortic Valvuloplasty for Severe Aortic Stenosis as Rescue or Bridge Therapy. J Clin Med 2021; 10:4657. [PMID: 34682783 PMCID: PMC8538854 DOI: 10.3390/jcm10204657] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2021] [Revised: 10/07/2021] [Accepted: 10/09/2021] [Indexed: 12/13/2022] Open
Abstract
The study aimed to assess procedural complications, patient flow and clinical outcomes after balloon aortic valvuloplasty (BAV) as rescue or bridge therapy, based on data from our registry. A total of 382 BAVs in 374 patients was performed. The main primary indication for BAV was a bridge for TAVI (n = 185, 49.4%). Other indications included a bridge for AVR (n = 26, 6.9%) and rescue procedure in hemodynamically unstable patients (n = 139, 37.2%). The mortality rate at 30 days, 6 and 12 months was 10.4%, 21.6%, 28.3%, respectively. In rescue patients, the death rate raised to 66.9% at 12 months. A significant improvement in symptoms was confirmed after BAV, after 30 days, 6 months, and in survivors after 1 year (p < 0.05 for all). Independent predictors of 12-month mortality were baseline STS score [HR (95% CI) 1.42 (1.34 to 2.88), p < 0.0001], baseline LVEF <20% [HR (95% CI) 1.89 (1.55-2.83), p < 0.0001] and LVEF <30% at 1 month [HR (95% CI) 1.97 (1.62-3.67), p < 0.0001] adjusted for age/gender. In everyday clinical practice in the TAVI era, there are still clinical indications to BAV a standalone procedure as a bridge to surgery, TAVI or for urgent high risk non-cardiac surgical procedures. Patients may improve clinically after BAV with LV function recovery, allowing to perform final therapy, within limited time window, for severe AS which ameliorates long-term outcomes. On the other hand, in patients for whom an isolated BAV becomes a destination therapy, prognosis is extremely poor.
Collapse
Affiliation(s)
- Pawel Kleczynski
- Department of Interventional Cardiology, Institute of Cardiology, Jagiellonian University Medical College, John Paul II Hospital, Pradnicka 80 Street, 31-202 Krakow, Poland; (J.T.); (M.S.); (J.L.)
| | - Aleksandra Kulbat
- Students’ Scientific Group at the Department of Interventional Cardiology, Jagiellonian University Medical College, John Paul II Hospital, Pradnicka 80 Street, 31-202 Krakow, Poland; (A.K.); (P.B.)
| | - Piotr Brzychczy
- Students’ Scientific Group at the Department of Interventional Cardiology, Jagiellonian University Medical College, John Paul II Hospital, Pradnicka 80 Street, 31-202 Krakow, Poland; (A.K.); (P.B.)
| | - Artur Dziewierz
- 2nd Department of Cardiology, Institute of Cardiology, Jagiellonian University Medical College, University Hospital, Jakubowskiego 2 Street, 30-688 Krakow, Poland; (A.D.); (D.S.); (L.R.); (S.B.); (D.D.)
| | - Jaroslaw Trebacz
- Department of Interventional Cardiology, Institute of Cardiology, Jagiellonian University Medical College, John Paul II Hospital, Pradnicka 80 Street, 31-202 Krakow, Poland; (J.T.); (M.S.); (J.L.)
| | - Maciej Stapor
- Department of Interventional Cardiology, Institute of Cardiology, Jagiellonian University Medical College, John Paul II Hospital, Pradnicka 80 Street, 31-202 Krakow, Poland; (J.T.); (M.S.); (J.L.)
| | - Danuta Sorysz
- 2nd Department of Cardiology, Institute of Cardiology, Jagiellonian University Medical College, University Hospital, Jakubowskiego 2 Street, 30-688 Krakow, Poland; (A.D.); (D.S.); (L.R.); (S.B.); (D.D.)
| | - Lukasz Rzeszutko
- 2nd Department of Cardiology, Institute of Cardiology, Jagiellonian University Medical College, University Hospital, Jakubowskiego 2 Street, 30-688 Krakow, Poland; (A.D.); (D.S.); (L.R.); (S.B.); (D.D.)
| | - Stanislaw Bartus
- 2nd Department of Cardiology, Institute of Cardiology, Jagiellonian University Medical College, University Hospital, Jakubowskiego 2 Street, 30-688 Krakow, Poland; (A.D.); (D.S.); (L.R.); (S.B.); (D.D.)
| | - Dariusz Dudek
- 2nd Department of Cardiology, Institute of Cardiology, Jagiellonian University Medical College, University Hospital, Jakubowskiego 2 Street, 30-688 Krakow, Poland; (A.D.); (D.S.); (L.R.); (S.B.); (D.D.)
| | - Jacek Legutko
- Department of Interventional Cardiology, Institute of Cardiology, Jagiellonian University Medical College, John Paul II Hospital, Pradnicka 80 Street, 31-202 Krakow, Poland; (J.T.); (M.S.); (J.L.)
| |
Collapse
|
5
|
Female gender and the clinical and periprocedural profile and clinical outcomes of transcatheter aortic valve implantation: experiences of a tertiary Polish centre. ADVANCES IN INTERVENTIONAL CARDIOLOGY 2020; 16:436-443. [PMID: 33598017 PMCID: PMC7863829 DOI: 10.5114/aic.2020.101769] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Accepted: 10/12/2020] [Indexed: 11/17/2022] Open
Abstract
Introduction Despite the establishment of multiple factors influencing short- and mid-term outcomes in patients treated with transcatheter aortic valve implantation (TAVI), the real-world data on the association between gender and outcomes after TAVI remain conflicting. Aim To evaluate the association of female gender with the clinical and periprocedural characteristics along with in-hospital, short- and medium-term outcomes of patients treated with TAVI in comparison with male patients. Material and methods Data from the prospective, single-centre registry of consecutive patients with severe AS referred for TAVI from 26 November 2008 to 31 December 2018 were analysed retrospectively. The study population comprised 275 patients who were divided by gender. The primary endpoint of the study was all-cause mortality at 1 year. Results Women constituted 132 (48.0%) of the overall population. Women were significantly older, but had a significantly higher left ventricular ejection fraction (LVEF) and had less frequently undergone coronary artery bypass grafting (CABG) before TAVI. The implantation success rate was comparable between genders, but women less frequently required implantation of a pacemaker after TAVI, although they more frequently required blood transfusion due to severe bleeding. The primary endpoint occurred in 13.6% of women and 7.7% of men (p = 0.12). Conclusions Despite advanced age and prevalence of cardiovascular risk factors, the overall short- and medium-term mortality in patients treated with TAVI in our analysis of the real-world population remains relatively low. Although women seemed to have a slightly better clinical baseline profile, their in-hospital, 30-day, 6-month and 12-month outcomes did not differ significantly from the male patients.
Collapse
|
6
|
Kleczynski P, Dziewierz A, Socha S, Rakowski T, Daniec M, Zawislak B, Arif S, Wojtasik-Bakalarz J, Dudek D, Rzeszutko L. Direct Rapid Left Ventricular Wire Pacing during Balloon Aortic Valvuloplasty. J Clin Med 2020; 9:jcm9041017. [PMID: 32260289 PMCID: PMC7230545 DOI: 10.3390/jcm9041017] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2020] [Revised: 03/27/2020] [Accepted: 03/31/2020] [Indexed: 11/16/2022] Open
Abstract
Background: Rapid ventricular pacing is mandatory for optimal balloon positioning during aortic valvuloplasty (BAV) in patients with severe aortic stenosis. We aimed to assess the safety and efficacy of direct left ventricular (LV) guidewire pacing in comparison with regular pacing induced by temporary pacemaker (PM) placement in the right ventricle. Methods: Direct rapid LV pacing was provided with a 0.035″ guidewire. Baseline clinical characteristics, echocardiographic and procedural data, as well as complication rates, were compared between the two groups. Results: A total of 202 patients undergoing BAV were enrolled (49.5% with direct LV guidewire pacing). The pacing success rate was 100%. In the direct LV guidewire pacing group, we found a lower radiation dose, shorter fluoroscopy and overall procedural time (0.16 vs. 0.28 Gy, p = 0.02; 5.4 vs. 10.3 min, p = 0.01; 17 vs. 25 min, p = 0.01; respectively). In addition, the complication rate was lower in that group (cardiac tamponades, vascular access site complications, blood transfusions rate, and in-hospital mortality: 0% vs. 3.9%; 4.0% vs. 15.7%; 2.0% vs. 12.7%; 2.0% vs. 9.8%, p = 0.01 for all, respectively). Conclusions: Direct rapid LV guidewire pacing is a simple, safe and effective option for BAV with a reduced complication rate compared to a temporary PM placed in the right ventricle.
Collapse
Affiliation(s)
- Pawel Kleczynski
- Department of Interventional Cardiology, Jagiellonian University Medical College, John Paul II Hospital, Pradnicka 80 Street, 31-202 Krakow, Poland
- 2nd Department of Cardiology, Jagiellonian University Medical College, University Hospital, Jakubowskiego 2 Street, 30-688 Krakow, Poland; (A.D.); (T.R.); (B.Z.); (D.D.)
- Correspondence:
| | - Artur Dziewierz
- 2nd Department of Cardiology, Jagiellonian University Medical College, University Hospital, Jakubowskiego 2 Street, 30-688 Krakow, Poland; (A.D.); (T.R.); (B.Z.); (D.D.)
| | - Sylwia Socha
- Department of Cardiology and Cardiovascular Interventions, University Hospital, Jakubowskiego 2 Street, 30-688 Krakow, Poland; (S.S.); (M.D.); (S.A.); (J.W.-B.); (L.R.)
| | - Tomasz Rakowski
- 2nd Department of Cardiology, Jagiellonian University Medical College, University Hospital, Jakubowskiego 2 Street, 30-688 Krakow, Poland; (A.D.); (T.R.); (B.Z.); (D.D.)
| | - Marzena Daniec
- Department of Cardiology and Cardiovascular Interventions, University Hospital, Jakubowskiego 2 Street, 30-688 Krakow, Poland; (S.S.); (M.D.); (S.A.); (J.W.-B.); (L.R.)
| | - Barbara Zawislak
- 2nd Department of Cardiology, Jagiellonian University Medical College, University Hospital, Jakubowskiego 2 Street, 30-688 Krakow, Poland; (A.D.); (T.R.); (B.Z.); (D.D.)
- Intensive Cardiac Care Unit, University Hospital, Jakubowskiego 2 Street, 30-688 Krakow, Poland
| | - Saleh Arif
- Department of Cardiology and Cardiovascular Interventions, University Hospital, Jakubowskiego 2 Street, 30-688 Krakow, Poland; (S.S.); (M.D.); (S.A.); (J.W.-B.); (L.R.)
| | - Joanna Wojtasik-Bakalarz
- Department of Cardiology and Cardiovascular Interventions, University Hospital, Jakubowskiego 2 Street, 30-688 Krakow, Poland; (S.S.); (M.D.); (S.A.); (J.W.-B.); (L.R.)
| | - Dariusz Dudek
- 2nd Department of Cardiology, Jagiellonian University Medical College, University Hospital, Jakubowskiego 2 Street, 30-688 Krakow, Poland; (A.D.); (T.R.); (B.Z.); (D.D.)
| | - Lukasz Rzeszutko
- Department of Cardiology and Cardiovascular Interventions, University Hospital, Jakubowskiego 2 Street, 30-688 Krakow, Poland; (S.S.); (M.D.); (S.A.); (J.W.-B.); (L.R.)
| |
Collapse
|