1
|
Arthur LW, Ghosh P, Mohammad HR, Campi S, Kendrick BJL, Murray DW, Mellon SJ. Polyethylene bearing wear is comparable for cemented and cementless Oxford unicompartmental knee replacements: Ten-year results of a randomized controlled trial. Knee Surg Sports Traumatol Arthrosc 2024; 32:405-417. [PMID: 38298004 DOI: 10.1002/ksa.12042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Revised: 12/11/2023] [Accepted: 12/11/2023] [Indexed: 02/02/2024]
Abstract
PURPOSE There is concern that using cementless components may increase polyethylene wear of the Oxford unicompartmental knee replacement (OUKR). Therefore, this study aimed to measure bearing wear at 10 years in patients from a randomized trial comparing Phase 3 cemented and cementless OUKRs and to investigate factors that may affect wear. It was hypothesized that there would be no difference in wear rate between cemented and cementless OUKRs. METHODS Bearing thickness was determined using radiostereometric analysis at postoperative, 3-month, 6-month, 1-year, 2-year, 5-year and 10-year timepoints. As creep occurs early, wear rate was calculated using linear regression between 6 months and 10 years for 39 knees (20 cemented, 19 cementless). Associations between wear and implant, surgical and patient factors were analysed. RESULTS The linear wear rate of the Phase 3 OUKR was 0.06 mm/year with no significant difference (p = 0.18) between cemented (0.054 mm/year) and cementless (0.063 mm/year) implants. Age, Oxford Knee Score, component size and bearing thickness had no correlation with wear. A body mass index ≥ 30 was associated with a significantly lower wear rate (p = 0.007) as was having ≥80% femoral component contact area on the bearing (p = 0.003). Bearings positioned ≥1.5 mm from the tibial wall had a significantly higher wear rate (p = 0.002). CONCLUSIONS At 10 years, the Phase 3 OUKR linear wear rate is low and not associated with the fixation method. To minimize the risk of wear-related bearing fracture in the very long-term surgeons should consider using 4 mm bearings in very young active patients and ensure that components are appropriately positioned, which is facilitated by the current instrumentation. LEVEL OF EVIDENCE Level III, retrospective comparative study.
Collapse
Affiliation(s)
- Lachlan W Arthur
- Nuffield Department of Orthopaedics, Rheumatology, and Musculoskeletal Sciences (NDORMS), Oxford Orthopaedic Engineering Centre, University of Oxford, Oxford, UK
| | - Priyanka Ghosh
- Nuffield Department of Orthopaedics, Rheumatology, and Musculoskeletal Sciences (NDORMS), Oxford Orthopaedic Engineering Centre, University of Oxford, Oxford, UK
| | - Hasan R Mohammad
- Nuffield Department of Orthopaedics, Rheumatology, and Musculoskeletal Sciences (NDORMS), Oxford Orthopaedic Engineering Centre, University of Oxford, Oxford, UK
| | - Stefano Campi
- Nuffield Department of Orthopaedics, Rheumatology, and Musculoskeletal Sciences (NDORMS), Oxford Orthopaedic Engineering Centre, University of Oxford, Oxford, UK
| | - Benjamin J L Kendrick
- Nuffield Department of Orthopaedics, Rheumatology, and Musculoskeletal Sciences (NDORMS), Oxford Orthopaedic Engineering Centre, University of Oxford, Oxford, UK
| | - David W Murray
- Nuffield Department of Orthopaedics, Rheumatology, and Musculoskeletal Sciences (NDORMS), Oxford Orthopaedic Engineering Centre, University of Oxford, Oxford, UK
| | - Stephen J Mellon
- Nuffield Department of Orthopaedics, Rheumatology, and Musculoskeletal Sciences (NDORMS), Oxford Orthopaedic Engineering Centre, University of Oxford, Oxford, UK
| |
Collapse
|
2
|
MOSEGAARD SB, JØRGENSEN PB, JAKOBSEN SS, DAUGAARD H, SØBALLE K, STILLING M. Larger 5-year migration but similar polyethylene wear of cementless hemispherical cups with electrochemically applied hydroxyapatite (BoneMaster) coating compared with porous plasma-spray titanium: a randomized 5-year RSA study. Acta Orthop 2022; 93:658-664. [PMID: 35848733 PMCID: PMC9290214 DOI: 10.2340/17453674.2022.3976] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE BoneMaster (BM) is a thin electrochemically applied hydroxyapatite (HA) implant coating marketed with expectations of improved osseointegration properties but less polyethylene (PE) wear. We compared the midterm cup migration and PE wear of cementless porous-coated hemispherical cups with and without BM. PATIENTS AND METHODS In this patient-blinded, randomized controlled trial, 53 patients with a mean age of 64 years (55-75) received total hip arthroplasty with a porous-coated (P) or porous and BoneMaster (PBM) coated Exceed cup and ArCom E1 infused PE. Patients were followed with RSA, Hip Osteoarthritis Outcome Score (HOOS), and Euro-Qol-5-3L (EQ-5D) at 3 and 6 months, and 1-, 2-, and 5-year follow-up. RESULTS At 5-year follow-up, total translation and maximum total point motion was 0.28 mm (95% CI 0.08; 0.47) and 0.52 mm (CI 0.12; 0.93) higher in the PBM group than in the P group. PE wear was comparable between PBM and P cups, and 2D wear rate from 1-year follow-up to last follow-up was 0.03 mm (CI 0.02-0.03). The 5-year anterior translation was 0.05 mm (CI -0.10 to 0.21) in the normal BMD group and 0.40 mm (CI 0.22-0.57) in the osteopenia group. INTERPRETATION At 5-year follow-up, Exceed cups in the PBM group migrated more than in the P group but the PE wear rate was low and similar. This study does not indicate any advantage of additional BoneMaster coating compared with porous coating alone on cementless hemispherical cups with regards to migration, polyethylene wear, and clinical outcomes.
Collapse
Affiliation(s)
- Sebastian Breddam MOSEGAARD
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus;,Department of Orthopedic Surgery, Aarhus University Hospital, Aarhus
| | - Peter Bo JØRGENSEN
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus;,Department of Clinical Medicine, Aarhus University, Aarhus
| | | | - Henrik DAUGAARD
- Department of Orthopedics, Slagelse Hospital, Slagelse, Denmark
| | - Kjeld SØBALLE
- Department of Orthopedic Surgery, Aarhus University Hospital, Aarhus;,Department of Clinical Medicine, Aarhus University, Aarhus
| | - Maiken STILLING
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus;,Department of Clinical Medicine, Aarhus University, Aarhus
| |
Collapse
|
3
|
Baker EA, Vara AD, Salisbury MR, Fleischer MM, Baker KC, Fortin PT, Roberts RV, Friedrich CR. Titania nanotube morphologies for osseointegration via models of in vitro osseointegrative potential and in vivo intramedullary fixation. J Biomed Mater Res B Appl Biomater 2020; 108:1483-1493. [DOI: 10.1002/jbm.b.34496] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Revised: 08/12/2019] [Accepted: 09/16/2019] [Indexed: 11/07/2022]
Affiliation(s)
- Erin A. Baker
- Department of Orthopaedic SurgeryBeaumont Health Royal Oak Michigan
- Department of Mechanical Engineering‐Engineering MechanicsMichigan Technological University Houghton Michigan
- Department of Orthopaedic SurgeryOakland University William Beaumont School of Medicine Rochester Michigan
| | | | | | | | - Kevin C. Baker
- Department of Orthopaedic SurgeryBeaumont Health Royal Oak Michigan
- Department of Orthopaedic SurgeryOakland University William Beaumont School of Medicine Rochester Michigan
| | - Paul T. Fortin
- Department of Orthopaedic SurgeryBeaumont Health Royal Oak Michigan
- Department of Orthopaedic SurgeryOakland University William Beaumont School of Medicine Rochester Michigan
| | | | - Craig R. Friedrich
- Department of Mechanical Engineering‐Engineering MechanicsMichigan Technological University Houghton Michigan
| |
Collapse
|
4
|
Bone ongrowth of a cementless silver oxide-containing hydroxyapatite-coated antibacterial acetabular socket. J Orthop Sci 2019; 24:658-662. [PMID: 30718042 DOI: 10.1016/j.jos.2018.12.031] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/17/2018] [Revised: 11/05/2018] [Accepted: 12/20/2018] [Indexed: 02/09/2023]
Abstract
BACKGROUND The silver oxide-containing hydroxyapatite-coated socket (KYOCERA, Osaka, Japan) is a cementless antibacterial implant that has both the osteoconductivity of the HA and the antibacterial activity of silver. The silver oxide-containing hydroxyapatite coating was shown to have good osteoconductivity and new bone formation in vitro and in vivo. However, the histological bone ongrowth of this implant has not been proven in a clinical study. METHODS We analyzed bone ongrowth using two silver oxide-containing hydroxyapatite-coated sockets that were removed in revision total hip arthroplasty for recurrent dislocation. A histomorphometric analysis was performed using a scanning electron microscope (SEM) connected to a CCD camera and an elemental analysis was performed by energy-dispersive elemental spectrometry (EDS). RESULT A white structure thought to be osseous tissue was attached to the retrieved socket surface macroscopically, and histological bone ongrowth of the silver oxide-containing hydroxyapatite coating of the socket was confirmed by SEM. In addition, the presence of silver in the silver oxide-containing hydroxyapatite coating was confirmed in an elemental analysis by EDS. CONCLUSION Histologically, the silver oxide-containing hydroxyapatite-coated socket presented bone ongrowth in this clinical study.
Collapse
|
5
|
Horsager K, Madsen F, Odgaard A, Fink Jepsen C, Rømer L, Kristensen PW, Kaptein BL, Søballe K, Stilling M. Similar polyethylene wear between cemented and cementless Oxford medial UKA: a 5-year follow-up randomized controlled trial on 79 patients using radiostereometry. Acta Orthop 2019; 90:67-73. [PMID: 30526183 PMCID: PMC6366473 DOI: 10.1080/17453674.2018.1543757] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Hydroxyapatite (HA)-coated implants have been associated with high polyethylene wear in hip arthroplasties. HA coating as a promoter of wear in knee arthroplasties has not been investigated. We compared the wear-rate of the polyethylene bearing for cemented and cementless HA-coated Oxford medial unicondylar knee arthroplasties (UKA). Secondarily, we investigated whether wear-rates were influenced by overhang or impingement of the bearing. Patients and methods - 80 patients (mean age 64 years), treatment-blinded, were randomized to 1 of 3 Oxford medial UKA versions: cemented with double-pegged or single-pegged femoral component or cementless HA-coated with double-pegged femoral component (ratios 1:1:1). We compared wear between the cemented (n = 55) and cementless group (n = 25) (ratio 2:1). Wear, impingement, and overhang were quantified between surgery and 5-year follow-up using radiostereometry. Clinical outcome was evaluated with the Oxford Knee Score. Results - The mean wear-rate for patients without bearing overhang was 0.04 mm/year (95% CI 0.02-0.07) for the cemented group and 0.05 mm/year (CI 0.02-0.08) for the cementless group. The mean difference in wear was 0.008 mm/year (CI -0.04 to 0.03). No impingement was identified. Half of the patients had medial bearing overhang, mean 2.5 mm (1-5). Wear increased by 0.014 mm/year for each mm increment in overhang. The mean Oxford Knee Score was 39 for the cementless group and 38 for the cemented group at the 5-year follow-up. Interpretation - The wear-rates were similar for the 2 fixation methods, which supports further use of the cementless Oxford medial UKA. However, a caveat is a relatively large 95% CI of the mean difference in wear-rate. Component size and position is important as half of the patients presented with an additional increase in wear-rate due to medial bearing overhang.
Collapse
Affiliation(s)
- Kristian Horsager
- Department of Clinical Institute, Aarhus University, Aarhus, Denmark
| | - Frank Madsen
- Department of Orthopedics, Aarhus University Hospital, Aarhus, Denmark
| | - Anders Odgaard
- Department of Orthopaedics, Herlev-Gentofte Hospital, Copenhagen University Hospital, Hellerup, Denmark
| | - Claus Fink Jepsen
- Department of Orthopedics, Aarhus University Hospital, Aarhus, Denmark
| | - Lone Rømer
- Department of Radiology, Aarhus University Hospital, Aarhus, Denmark
| | | | - Bart L Kaptein
- Department of Orthopedic Surgery, Biomechanics and Imaging Group, Leiden University Medical Center, Leiden, Netherlands
| | - Kjeld Søballe
- Department of Clinical Institute, Aarhus University, Aarhus, Denmark
| | - Maiken Stilling
- Department of Clinical Institute, Aarhus University, Aarhus, Denmark
| |
Collapse
|
6
|
Tabori-Jensen S, Frølich C, Hansen TB, Bøvling S, Homilius M, Stilling M. Higher UHMWPE wear-rate in cementless compared with cemented cups with the Saturne® Dual-Mobility acetabular system. Hip Int 2018; 28:125-132. [PMID: 29890909 DOI: 10.1177/1120700018768615] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION Dual mobility (DM) total hip arthroplasty (THA) may reduce dislocation risk, but might increase the risk of high polyethylene (PE) wear due to double wearing surfaces. METHODS 127 patients (97 female) with 129 hips operated with THA after displaced femoral neck fracture FNF between 2005 and 2011, were seen for a cross-sectional clinical follow-up. Acetabular components were Saturne® DM cups with 28mm chrome-cobalt heads in UHMWPE. Cementless cups (n = 73) were hydroxyapatite coated. Radiographs were obtained for analysis of cup placement, 2D polyethylene wear and wear-rate (PolyWare 3D), and further radiological evaluation. Activity measurements included Timed Up and Go test (TUG) and walking distance from Harris Hip Score (HHS). RESULTS At a mean follow-up of 2.83 (1.0-7.7) years the mean wear was 0.82 mm (range 0.17-4.51, SD 0.50), and the wear-rate was 0.37 mm (range 0.06-1.90, SD 0.29). Wear-rate of 0.43 mm/year (SD 0.30) in cementless cups was higher (p = 0.004) than 0.30 mm/year (SD 0.27) in cemented cups. Mean age at time of surgery was 75.1 years (range 30-95). There was no correlation between age at time of surgery and wear (p = 0.56). There was no correlation between cup inclination and wear-rate (p = 0.35). TUG was mean 13.4 seconds (range 4.5-30.1) and correlated with wear rate (p = 0.03). CONCLUSIONS At short term follow-up, the mean wear-rate in old and low demand patients was high, correlated to activity, and was above the generally accepted osteolysis threshold (0.1 mm/yr.). Cementless HA-coated cups had higher wear-rate than cemented cups.
Collapse
Affiliation(s)
- Steffan Tabori-Jensen
- 1 Department of Orthopaedics, University Clinic for Hand, Hip and Knee Surgery, Hospital Unit West, Holstebro - Denmark.,2 Department of Clinical Medicine, Aarhus University, Aarhus - Denmark
| | - Christina Frølich
- 1 Department of Orthopaedics, University Clinic for Hand, Hip and Knee Surgery, Hospital Unit West, Holstebro - Denmark.,2 Department of Clinical Medicine, Aarhus University, Aarhus - Denmark
| | - Torben B Hansen
- 1 Department of Orthopaedics, University Clinic for Hand, Hip and Knee Surgery, Hospital Unit West, Holstebro - Denmark.,2 Department of Clinical Medicine, Aarhus University, Aarhus - Denmark
| | - Søren Bøvling
- 1 Department of Orthopaedics, University Clinic for Hand, Hip and Knee Surgery, Hospital Unit West, Holstebro - Denmark
| | - Morten Homilius
- 1 Department of Orthopaedics, University Clinic for Hand, Hip and Knee Surgery, Hospital Unit West, Holstebro - Denmark
| | - Maiken Stilling
- 1 Department of Orthopaedics, University Clinic for Hand, Hip and Knee Surgery, Hospital Unit West, Holstebro - Denmark.,2 Department of Clinical Medicine, Aarhus University, Aarhus - Denmark
| |
Collapse
|
7
|
Does hydroxyapatite coating of uncemented cups improve long-term survival? An analysis of 28,605 primary total hip arthroplasty procedures from the Nordic Arthroplasty Register Association (NARA). Osteoarthritis Cartilage 2017; 25:1980-1987. [PMID: 28802851 DOI: 10.1016/j.joca.2017.08.001] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/14/2017] [Revised: 06/23/2017] [Accepted: 08/03/2017] [Indexed: 02/02/2023]
Abstract
OBJECTIVE It is unclear whether hydroxyapatite (HA) coating of uncemented cups used in primary total hip arthroplasty (THA) improves bone ingrowth and reduces the risk of aseptic loosening. We therefore investigated survival of different uncemented cups that were available with or without HA coating. METHOD We investigated three different cup types used with or without HA coating registered in the Nordic Arthroplasty Register Association (NARA) database that were inserted due to osteoarthritis (n = 28,605). Cumulative survival rates and adjusted hazard ratios (HRs) for the risk of revision were calculated. RESULTS Unadjusted 13-year survival for cup revision due to aseptic loosening was 97.9% (CI: 96.5-99.4) for uncoated and 97.8% (CI: 96.3-99.4) for HA-coated cups. Adjusted HRs were 0.66 (CI 0.42-1.04) for the presence of HA coating during the first 10 years and 0.87 (CI 0.14-5.38) from year 10-13, compared with uncoated cups. When considering the endpoint cup revision for any reason, unadjusted 13-year survival was similar for uncoated (92.5% [CI: 90.1-94.9]) and HA-coated (94.7% [CI: 93.2-96.3]) cups. The risk of revision of any component due to infection was higher in THA with HA-coated cups than in THA with uncoated cups (adjusted HR 1.4 [CI 1.1-1.9]). CONCLUSIONS HA-coated cups have a similar risk of aseptic loosening as uncoated cups, thus the use of HA coating seems to not confer any added value in terms of implant stability. The risk of infection seemed higher in THA with use of HA-coated cups, an observation that must be investigated further.
Collapse
|
8
|
Tabori-Jensen S, Frølich C, Hansen TB, Bøvling S, Homilius M, Stilling M. Higher UHMWPE wear-rate in cementless compared with cemented cups with the Saturne® Dual-Mobility acetabular system. Hip Int 2017:0. [PMID: 28967052 DOI: 10.5301/hipint.5000540] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 05/20/2017] [Indexed: 02/04/2023]
Abstract
INTRODUCTION Dual mobility (DM) total hip arthroplasty (THA) may reduce dislocation risk, but might increase the risk of high polyethylene (PE) wear due to double wearing surfaces. METHODS 127 patients (97 female) with 129 hips operated with THA after displaced femoral neck fracture FNF between 2005 and 2011, were seen for a cross-sectional clinical follow-up. Acetabular components were Saturne® DM cups with 28mm chrome-cobalt heads in UHMWPE. Cementless cups (n = 73) were hydroxyapatite coated. Radiographs were obtained for analysis of cup placement, 2D polyethylene wear and wear-rate (PolyWare 3D), and further radiological evaluation. Activity measurements included Timed Up and Go test (TUG) and walking distance from Harris Hip Score (HHS). RESULTS At a mean follow-up of 2.83 (1.0-7.7) years the mean wear was 0.82 mm (range 0.17-4.51, SD 0.50), and the wear-rate was 0.37 mm (range 0.06-1.90, SD 0.29). Wear-rate of 0.43 mm/year (SD 0.30) in cementless cups was higher (p = 0.004) than 0.30 mm/year (SD 0.27) in cemented cups. Mean age at time of surgery was 75.1 years (range 30-95). There was no correlation between age at time of surgery and wear (p = 0.56). There was no correlation between cup inclination and wear-rate (p = 0.35). TUG was mean 13.4 seconds (range 4.5-30.1) and correlated with wear rate (p = 0.03). CONCLUSIONS At short term follow-up, the mean wear-rate in old and low demand patients was high, correlated to activity, and was above the generally accepted osteolysis threshold (0.1 mm/yr.). Cementless HA-coated cups had higher wear-rate than cemented cups.
Collapse
Affiliation(s)
- Steffan Tabori-Jensen
- Department of Orthopaedics, University Clinic for Hand, Hip and Knee Surgery, Hospital Unit West, Holstebro - Denmark
- Department of Clinical Medicine, Aarhus University, Aarhus - Denmark
| | - Christina Frølich
- Department of Orthopaedics, University Clinic for Hand, Hip and Knee Surgery, Hospital Unit West, Holstebro - Denmark
- Department of Clinical Medicine, Aarhus University, Aarhus - Denmark
| | - Torben B Hansen
- Department of Orthopaedics, University Clinic for Hand, Hip and Knee Surgery, Hospital Unit West, Holstebro - Denmark
- Department of Clinical Medicine, Aarhus University, Aarhus - Denmark
| | - Søren Bøvling
- Department of Orthopaedics, University Clinic for Hand, Hip and Knee Surgery, Hospital Unit West, Holstebro - Denmark
| | - Morten Homilius
- Department of Orthopaedics, University Clinic for Hand, Hip and Knee Surgery, Hospital Unit West, Holstebro - Denmark
| | - Maiken Stilling
- Department of Orthopaedics, University Clinic for Hand, Hip and Knee Surgery, Hospital Unit West, Holstebro - Denmark
- Department of Clinical Medicine, Aarhus University, Aarhus - Denmark
| |
Collapse
|
9
|
Survival of hydroxyapatite-coated cups: acetabular screws involve a lower rate of revision surgery due to aseptic loosening. Hip Int 2017; 27:153-161. [PMID: 28165590 DOI: 10.5301/hipint.5000435] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 06/17/2016] [Indexed: 02/04/2023]
Abstract
BACKGROUND It is believed that the path of acetabular screws may represent a shuttle between hydroxyapatite (HA) particles and the liner. The aim was to assess the relationship between acetabular screws and revision surgery for aseptic loosening in total hip arthroplasties (THAs). MATERIAL AND METHODS A retrospective multicentric study was performed. Patients older than 18 years and patients who underwent THA with both the stem and cup HA-coated were included. The rate of revision-surgery considering only aseptic loosening was calculated. The proportion of cases in which acetabular screws were used was registered, as well as the proportion of cups that showed osteolysis. The statistical relationship between acetabular screws and osteolysis, as well as acetabular screws and revision-surgery for aseptic loosening were assessed. RESULTS There were 749 cases. Mean age 62.1 (45-84) years. Mean follow-up 14.19 (8.9-16.7) years. Revision surgery was performed in 12.8% (96/749) of the cups. 73.95% (71/96) of the revised cups showed aseptic loosening. The overall 15-year survival of the cups considering only aseptic loosening was 84.4%. Acetabular screws were used in 47.5% (356/749) of the cups. Acetabular screws were used in 40.44% (55/136) of the cups that showed osteolysis. The use of acetabular screws was associated with less osteolysis (p = 0.006). Acetabular screws were used in 35.21% (25/71) of the cups that were revised for aseptic loosening. The use of acetabular screws was associated with a lower rate of revision surgery (p = 0.020). CONCLUSIONS In THA with the stem and cup HA-coated, the use of acetabular screws is associated with a lower rate of revision surgery.
Collapse
|
10
|
Sato T, Nakashima Y, Komiyama K, Yamamoto T, Motomura G, Iwamoto Y. The Absence of Hydroxyapatite Coating on Cementless Acetabular Components Does Not Affect Long-Term Survivorship in Total Hip Arthroplasty. J Arthroplasty 2016; 31:1228-1232. [PMID: 26730449 DOI: 10.1016/j.arth.2015.11.034] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/16/2015] [Revised: 11/20/2015] [Accepted: 11/23/2015] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Hydroxyapatite (HA) has been applied to joint prostheses as a bioactive coating to prolong their durability. However, HA benefits for cup survival in total hip arthroplasty (THA) remain controversial. In this study, we compared the survival of cups with and without HA coating during a minimum follow-up of 18 years. METHODS In total, 183 THA cases in 163 patients were analyzed, including 73 cups with HA coating (HA(+) group) and 110 without HA coating (HA(-) group); otherwise, the cups had identical titanium-sprayed rough surfaces and were fixed with screws. In both groups, the same conventional polyethylene liners were applied. Zirconia and alumina ceramic heads were used in the HA(+) and HA(-) groups, respectively. We retrospectively analyzed cup survival based on cup revision for any reason or aseptic loosening as end points. RESULTS In total, 7 and 8 revisions were performed in the HA(-) and HA(+) groups with survival rates of 86.3% and 90.1%, respectively. Among them, 3 cups in the HA(-) group and 1 cup in the HA(+) group were revised for aseptic loosening in 20 years (survival rates 94.1% and 98.7%, respectively). No significant difference was detected in cup survival rates between the groups based on both end points. There were no stem revisions during the observation period. CONCLUSION The results suggested that HA coating did not have either beneficial or adverse effects on the long-term cup survival in primary cementless THA.
Collapse
Affiliation(s)
- Taishi Sato
- Department of Orthopaedic Surgery, Kyushu University, Fukuoka City, Fukuoka, Japan
| | - Yasuharu Nakashima
- Department of Orthopaedic Surgery, Kyushu University, Fukuoka City, Fukuoka, Japan
| | - Keisuke Komiyama
- Department of Orthopaedic Surgery, Kyushu University, Fukuoka City, Fukuoka, Japan
| | - Takuaki Yamamoto
- Department of Orthopaedic Surgery, Kyushu University, Fukuoka City, Fukuoka, Japan
| | - Goro Motomura
- Department of Orthopaedic Surgery, Kyushu University, Fukuoka City, Fukuoka, Japan
| | - Yukihide Iwamoto
- Department of Orthopaedic Surgery, Kyushu University, Fukuoka City, Fukuoka, Japan
| |
Collapse
|
11
|
So K, Goto K, Kuroda Y, Matsuda S. Minimum 10-Year Wear Analysis of Highly Cross-Linked Polyethylene in Cementless Total Hip Arthroplasty. J Arthroplasty 2015; 30:2224-6. [PMID: 26231076 DOI: 10.1016/j.arth.2015.06.053] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/02/2015] [Revised: 06/21/2015] [Accepted: 06/25/2015] [Indexed: 02/01/2023] Open
Abstract
Fifty-four patients (64 hips) underwent cementless total hip arthroplasty between 2000 and 2003 with a 22-mm zirconia ceramic bearing on highly cross-linked polyethylene, and were evaluated with a mean 11.9-year postoperative follow-up (range, 10-14 years). Linear wear was measured on the anteroposterior radiograph of the hip. No evidence of osteolysis and loosening was found on the final radiograph in any of the cases, and the steady-state linear wear rate was 0.017±0.018 mm/year. No significant correlation was found between the linear wear rate and age, body weight, cup inclination angle, or polyethylene thickness. Highly cross-linked polyethylene showed excellent wear resistance for >10 years when used in combination with 22-mm zirconia heads.
Collapse
Affiliation(s)
- Kazutaka So
- Department of Orthopaedics Surgery, Kyoto University Graduate School of Medicine, Sakyo-ku, Kyoto, Japan
| | - Koji Goto
- Department of Orthopaedics Surgery, Kyoto University Graduate School of Medicine, Sakyo-ku, Kyoto, Japan
| | - Yutaka Kuroda
- Department of Orthopaedics Surgery, Kyoto University Graduate School of Medicine, Sakyo-ku, Kyoto, Japan
| | - Shuichi Matsuda
- Department of Orthopaedics Surgery, Kyoto University Graduate School of Medicine, Sakyo-ku, Kyoto, Japan
| |
Collapse
|
12
|
Cementless hydroxyapatite coated hip prostheses. BIOMED RESEARCH INTERNATIONAL 2015; 2015:386461. [PMID: 25802848 PMCID: PMC4352755 DOI: 10.1155/2015/386461] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/28/2014] [Revised: 12/16/2014] [Accepted: 12/30/2014] [Indexed: 12/13/2022]
Abstract
More than twenty years ago, hydroxyapatite (HA), calcium phosphate ceramics, was introduced as a coating for cementless hip prostheses. The choice of this ceramic is due to its composition being similar to organic apatite bone crystals. This ceramic is biocompatible, bioactive, and osteoconductive. These qualities facilitate the primary stability and osseointegration of implants. Our surgical experience includes the implantation of more than 4,000 cementless hydroxyapatite coated hip prostheses since 1990. The models implanted are coated with HA in the acetabulum and in the metaphyseal area of the stem. The results corresponding to survival and stability of implants were very satisfactory in the long-term. From our experience, HA-coated hip implants are a reliable alternative which can achieve long term survival, provided that certain requirements are met: good design selection, sound choice of bearing surfaces based on patient life expectancy, meticulous surgical technique, and indications based on adequate bone quality.
Collapse
|
13
|
Clinical and Radiographic Outcomes with a Hydroxyapatite and Porous Coated Cup Design. ACTA ACUST UNITED AC 2014. [DOI: 10.1155/2014/302969] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Press-fit, hydroxyapatite-coated acetabular cup designs may offer a lower incidence of loosening and migration than older designs. Our study evaluated the initial clinical and radiographic success of a cementless acetabular shell in a large cohort of primary total hip arthroplasty (THA) patients. We queried our institution’s prospectively collected registry for a series of 771 primary THAs (695 patients) implanted with this cup by 4 high-volume arthroplasty surgeons. Of the 613 hips with minimum 2-year followup, average HHS (Harris Hip Score) was 93.6, WOMAC (Western Ontario and McMaster Universities Osteoarthritis Index) was 87.6, and VAS (Visual Analog Scale) pain score was 1.2. While there was a 2% reoperation rate (12 hips), none of the cups were revised for aseptic loosening. No radiolucencies were found and there was no evidence of acetabular loosening. At early followup, this newer cementless acetabular cup implant design exhibits high survivorship and clinical success.
Collapse
|
14
|
Schwartsmann CR, de Freitas Spinelli L, Boschin LC, Gonçalves RZ, Yépez AK, Strohaecker TR, de Souza RW. Dimensional analysis of total hip arthroplasty polyethylenes. Rev Bras Ortop 2013; 48:500-504. [PMID: 31304160 PMCID: PMC6565973 DOI: 10.1016/j.rboe.2013.12.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2012] [Accepted: 10/03/2012] [Indexed: 12/03/2022] Open
Abstract
Objective This paper performs a dimensional analysis of different total hip arthroplasty polyethylenes, cemented and non-cemented, Brazilian made and imported. Methods It was considered acetabular components with 50 mm for the 28 mm femoral heads. Dimensional analysis was performed on a 3D coordinate Carl-Zeiss robotic device. Polyethylene thickness and its external measurements (maximum diameter and diameter for the femoral head) were measured. Results The minimum thickness of the polyethylene was guaranteed on all tested components. The thickness of cemented acetabular varied from 19.185 mm to 25.358 mm, while the thickness of the non-cemented acetabular varied from 12.451 mm to 19.232 mm. The thickness was 27.96% lower in non-cemented acetabular components. With respect to the polyethylene acetabular cavity that receives the femoral head, all internal diameters exhibit at least 28 mm. In relation to the maximum outer diameter of the polyethylene, only one cemented acetabular component reached 50 mm in diameter. Conclusions There are large differences in measurements between brands and models analyzed. Cementless acetabular components have the smaller thickness. The diameters of non-cemented acetabular were also lower than those cemented at the expense of their need to insert into the metal-back.
Collapse
Affiliation(s)
- Carlos Roberto Schwartsmann
- Universidade Federal de Ciências de Saúde de Porto Alegre, Porto Alegre, RS, Brazil.,Serviço de Ortopedia e Traumatologia, Complexo Hospitalar da Santa Casa de Porto Alegre, Porto Alegre, RS, Brazil
| | - Leandro de Freitas Spinelli
- Serviço de Ortopedia e Traumatologia, Complexo Hospitalar da Santa Casa de Porto Alegre, Porto Alegre, RS, Brazil
| | - Leonardo Carbonera Boschin
- Serviço de Ortopedia e Traumatologia, Complexo Hospitalar da Santa Casa de Porto Alegre, Porto Alegre, RS, Brazil
| | - Ramiro Zilles Gonçalves
- Serviço de Ortopedia e Traumatologia, Complexo Hospitalar da Santa Casa de Porto Alegre, Porto Alegre, RS, Brazil
| | - Anthony Kerbes Yépez
- Serviço de Ortopedia e Traumatologia, Complexo Hospitalar da Santa Casa de Porto Alegre, Porto Alegre, RS, Brazil
| | - Telmo Roberto Strohaecker
- Laboratório de Metalurgia Física, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS, Brazil
| | - Ralf Wellis de Souza
- Laboratório de Metalurgia Física, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS, Brazil
| |
Collapse
|
15
|
Valancius K, Søballe K, Nielsen PT, Laursen MB. No superior performance of hydroxyapatite-coated acetabular cups over porous-coated cups. Acta Orthop 2013; 84:544-8. [PMID: 24171680 PMCID: PMC3851667 DOI: 10.3109/17453674.2013.854665] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Hydroxyapatite (HA) coating is believed to improve bone-implant ingrowth and long-term survival of prostheses. Recent studies, however, have challenged this view. Furthermore, HA particles may produce third-body wear and initiate aseptic loosening of implants. We report the performance of HA- and porous-coated acetabular cups in a prospective randomized trial. METHODS This was an 8-year follow-up study of our previously published prospective randomized study to compare clinical outcomes, survival, periprosthetic bone mineral density, migration, and wear rates of HA- and porous-coated acetabular cups. Dual X-ray absorptiometry (DXA) and Ein Bild Roentgen Analyse (EBRA) measurements were used. 100 patients who underwent unilateral cementless total hip arthroplasty were randomized to either porous-coated cups or HA-coated cups. Patients were examined preoperatively and at 3, 6, and 9 months, and also 1, 3, and 8 years after surgery. 81 patients were available for 8-year follow-up, 40 with porous-coated cups and 41 with HA-coated cups. RESULTS Age, sex, bone mineral density, and clinical results (Harris hip score) were similar in the 2 groups. The survival, wear, and migration patterns of the cups were also similar in both groups. The results of periprosthetic bone mineral density scans in region of interest 2 was in favor of the porous-coated cups, but there were no differences between the 2 groups in all the remaining regions of interest. INTERPRETATION HA coating had no statistically significant effect on clinical results, survival, wear, or migration at the 8-year follow-up.
Collapse
Affiliation(s)
- Kestutis Valancius
- Farsoe Clinic of Hip and Knee Arthroplasty, Department of Orthopaedic Surgery, Aalborg University Hospital, Aalborg
| | - Kjeld Søballe
- Hip Surgery Unit, Department of Orthopaedic Surgery, Aarhus University Hospital, Aarhus, Denmark
| | - Poul T Nielsen
- Farsoe Clinic of Hip and Knee Arthroplasty, Department of Orthopaedic Surgery, Aalborg University Hospital, Aalborg
| | - Mogens B Laursen
- Farsoe Clinic of Hip and Knee Arthroplasty, Department of Orthopaedic Surgery, Aalborg University Hospital, Aalborg
| |
Collapse
|
16
|
Análise dimensional de diferentes acetábulos usados na artroplastia total do quadril. Rev Bras Ortop 2013. [DOI: 10.1016/j.rbo.2012.10.011] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|