1
|
McLean ST, Holkup S, Tchir A, Mojoudi M, Hassan M, Taveras C, Ozge SO, James FM, Yeh H, Uygun K, Longchamp A. UW Supplementation with AP39 Improves Liver Viability Following Static Cold Storage. RESEARCH SQUARE 2024:rs.3.rs-4487319. [PMID: 38947096 PMCID: PMC11213193 DOI: 10.21203/rs.3.rs-4487319/v1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/02/2024]
Abstract
Static cold storage of donor livers at 4°C incompletely arrests metabolism, ultimately leading to decreases in ATP levels, oxidative stress, cell death, and organ failure. Hydrogen Sulfide (H2S) is an endogenously produced gas, previously demonstrated to reduce oxidative stress, reduce ATP depletion, and protect from ischemia and reperfusion injury. H2S is difficult to administer due to its rapid release curve, resulting in cellular death at high concentrations. AP39, a mitochondrially targeted, slow-release H2S donor, has been shown to reduce ischemia-reperfusion injury in hearts and kidneys. Thus, we investigated whether the addition of AP39 during 3-day static cold storage can improve liver graft viability. At the end of storage, livers underwent six hours of acellular normothermic machine perfusion, a model of transplantation. During simulated transplantation, livers stored with AP39 showed reduced resistance, reduced cellular damage (ALT and AST), and reduced apoptosis. Additionally, bile production and glucose, as well as energy charge were improved by the addition of AP39. These results indicate that AP39 supplementation improves liver viability during static cold storage.
Collapse
Affiliation(s)
| | - Saige Holkup
- Massachusetts General Hospital, Harvard Medical School
| | | | | | | | | | - S Ozgur Ozge
- Massachusetts General Hospital, Harvard Medical School
| | | | - Heidi Yeh
- Massachusetts General Hospital, Harvard Medical School
| | - Korkut Uygun
- Massachusetts General Hospital, Harvard Medical School
| | | |
Collapse
|
2
|
Goutard M, Tawa P, Berkane Y, Andrews AR, Pendexter CA, de Vries RJ, Pozzo V, Romano G, Lancia HH, Filz von Reiterdank I, Bertheuil N, Rosales IA, How IDAL, Randolph MA, Lellouch AG, Cetrulo CL, Uygun K. Machine Perfusion Enables 24-h Preservation of Vascularized Composite Allografts in a Swine Model of Allotransplantation. Transpl Int 2024; 37:12338. [PMID: 38813393 PMCID: PMC11133529 DOI: 10.3389/ti.2024.12338] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Accepted: 05/01/2024] [Indexed: 05/31/2024]
Abstract
The current gold standard for preserving vascularized composite allografts (VCA) is 4°C static cold storage (SCS), albeit muscle vulnerability to ischemia can be described as early as after 2 h of SCS. Alternatively, machine perfusion (MP) is growing in the world of organ preservation. Herein, we investigated the outcomes of oxygenated acellular subnormothermic machine perfusion (SNMP) for 24-h VCA preservation before allotransplantation in a swine model. Six partial hindlimbs were procured on adult pigs and preserved ex vivo for 24 h with either SNMP (n = 3) or SCS (n = 3) before heterotopic allotransplantation. Recipient animals received immunosuppression and were followed up for 14 days. Clinical monitoring was carried out twice daily, and graft biopsies and blood samples were regularly collected. Two blinded pathologists assessed skin and muscle samples. Overall survival was higher in the SNMP group. Early euthanasia of 2 animals in the SCS group was linked to significant graft degeneration. Analyses of the grafts showed massive muscle degeneration in the SCS group and a normal aspect in the SNMP group 2 weeks after allotransplantation. Therefore, this 24-h SNMP protocol using a modified Steen solution generated better clinical and histological outcomes in allotransplantation when compared to time-matched SCS.
Collapse
Affiliation(s)
- Marion Goutard
- Division of Plastic and Reconstructive Surgery, Massachusetts General Hospital, Boston, MA, United States
- Harvard Medical School, Boston, MA, United States
- Shriners Children’s Boston, Boston, MA, United States
| | - Pierre Tawa
- Division of Plastic and Reconstructive Surgery, Massachusetts General Hospital, Boston, MA, United States
- Harvard Medical School, Boston, MA, United States
- Shriners Children’s Boston, Boston, MA, United States
| | - Yanis Berkane
- Division of Plastic and Reconstructive Surgery, Massachusetts General Hospital, Boston, MA, United States
- Harvard Medical School, Boston, MA, United States
- Shriners Children’s Boston, Boston, MA, United States
- Suivi Immunologique des Thérapeutiques Innovantes Laboratory, INSERM U1236, University of Rennes 1, Rennes, France
- Department of Plastic, Reconstructive, and Aesthetic Surgery, Centre Hospitalier Universitaire de Rennes, Université de Rennes 1, Rennes, France
| | - Alec R. Andrews
- Division of Plastic and Reconstructive Surgery, Massachusetts General Hospital, Boston, MA, United States
- Harvard Medical School, Boston, MA, United States
- Shriners Children’s Boston, Boston, MA, United States
| | - Casie A. Pendexter
- Harvard Medical School, Boston, MA, United States
- Shriners Children’s Boston, Boston, MA, United States
- Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Boston, MA, United States
| | - Reinier J. de Vries
- Harvard Medical School, Boston, MA, United States
- Shriners Children’s Boston, Boston, MA, United States
- Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Boston, MA, United States
- Department of Surgery, Amsterdam University Medical Centers—Location AMC, University of Amsterdam, Amsterdam, Netherlands
| | - Victor Pozzo
- Division of Plastic and Reconstructive Surgery, Massachusetts General Hospital, Boston, MA, United States
- Harvard Medical School, Boston, MA, United States
- Shriners Children’s Boston, Boston, MA, United States
| | - Golda Romano
- Division of Plastic and Reconstructive Surgery, Massachusetts General Hospital, Boston, MA, United States
- Harvard Medical School, Boston, MA, United States
- Shriners Children’s Boston, Boston, MA, United States
| | - Hyshem H. Lancia
- Division of Plastic and Reconstructive Surgery, Massachusetts General Hospital, Boston, MA, United States
- Harvard Medical School, Boston, MA, United States
- Shriners Children’s Boston, Boston, MA, United States
| | - Irina Filz von Reiterdank
- Division of Plastic and Reconstructive Surgery, Massachusetts General Hospital, Boston, MA, United States
- Harvard Medical School, Boston, MA, United States
- Shriners Children’s Boston, Boston, MA, United States
- Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Boston, MA, United States
- University Medical Center Utrecht, Utrecht University, Utrecht, Netherlands
| | - Nicolas Bertheuil
- Suivi Immunologique des Thérapeutiques Innovantes Laboratory, INSERM U1236, University of Rennes 1, Rennes, France
- Department of Plastic, Reconstructive, and Aesthetic Surgery, Centre Hospitalier Universitaire de Rennes, Université de Rennes 1, Rennes, France
| | - Ivy A. Rosales
- Immunopathology Research Laboratory, Center for Transplantation Sciences, Massachusetts General Hospital, Boston, MA, United States
- Department of Pathology, Harvard Medical School, Boston, MA, United States
| | - Ira Doressa Anne L. How
- Immunopathology Research Laboratory, Center for Transplantation Sciences, Massachusetts General Hospital, Boston, MA, United States
- Department of Pathology, Harvard Medical School, Boston, MA, United States
| | - Mark A. Randolph
- Division of Plastic and Reconstructive Surgery, Massachusetts General Hospital, Boston, MA, United States
- Harvard Medical School, Boston, MA, United States
- Shriners Children’s Boston, Boston, MA, United States
| | - Alexandre G. Lellouch
- Division of Plastic and Reconstructive Surgery, Massachusetts General Hospital, Boston, MA, United States
- Harvard Medical School, Boston, MA, United States
- Shriners Children’s Boston, Boston, MA, United States
| | - Curtis L. Cetrulo
- Division of Plastic and Reconstructive Surgery, Massachusetts General Hospital, Boston, MA, United States
- Harvard Medical School, Boston, MA, United States
- Shriners Children’s Boston, Boston, MA, United States
| | - Korkut Uygun
- Harvard Medical School, Boston, MA, United States
- Shriners Children’s Boston, Boston, MA, United States
- Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Boston, MA, United States
| |
Collapse
|
3
|
Jain R, Ajenu EO, Lopera Higuita M, Hafiz EOA, Muzikansky A, Romfh P, Tessier SN. Real-time monitoring of mitochondrial oxygenation during machine perfusion using resonance Raman spectroscopy predicts organ function. Sci Rep 2024; 14:7328. [PMID: 38538723 PMCID: PMC10973340 DOI: 10.1038/s41598-024-57773-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Accepted: 03/21/2024] [Indexed: 04/04/2024] Open
Abstract
Organ transplantation is a life-saving procedure affecting over 100,000 people on the transplant waitlist. Ischemia reperfusion injury (IRI) is a major challenge in the field as it can cause post-transplantation complications and limit the use of organs from extended criteria donors. Machine perfusion technology has the potential to mitigate IRI; however, it currently fails to achieve its full potential due to a lack of highly sensitive and specific assays to assess organ quality during perfusion. We developed a real-time and non-invasive method of assessing organs during perfusion based on mitochondrial function and injury using resonance Raman spectroscopy. It uses a 441 nm laser and a high-resolution spectrometer to quantify the oxidation state of mitochondrial cytochromes during perfusion. This index of mitochondrial oxidation, or 3RMR, was used to understand differences in mitochondrial recovery of cold ischemic rodent livers during machine perfusion at normothermic temperatures with an acellular versus cellular perfusate. Measurement of the mitochondrial oxidation revealed that there was no difference in 3RMR of fresh livers as a function of normothermic perfusion when comparing acellular versus cellular-based perfusates. However, following 24 h of static cold storage, 3RMR returned to baseline faster with a cellular-based perfusate, yet 3RMR progressively increased during perfusion, indicating injury may develop over time. Thus, this study emphasizes the need for further refinement of a reoxygenation strategy during normothermic machine perfusion that considers cold ischemia durations, gradual recovery/rewarming, and risk of hemolysis.
Collapse
Affiliation(s)
- Rohil Jain
- Center for Engineering in Medicine and Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, MA, USA
- Shriners Children's Hospital, Boston, MA, USA
| | - Emmanuella O Ajenu
- Center for Engineering in Medicine and Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, MA, USA
- Shriners Children's Hospital, Boston, MA, USA
| | - Manuela Lopera Higuita
- Center for Engineering in Medicine and Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, MA, USA
- Shriners Children's Hospital, Boston, MA, USA
| | - Ehab O A Hafiz
- Department of Electron Microscopy Research, Clinical Laboratory Division, Theodor Bilharz Research Institute, Giza, Egypt
| | - Alona Muzikansky
- Biostatistics Center, Massachusetts General Hospital, Boston, MA, USA
| | | | - Shannon N Tessier
- Center for Engineering in Medicine and Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, MA, USA.
- Shriners Children's Hospital, Boston, MA, USA.
| |
Collapse
|
4
|
Jain R, Ajenu EO, Hafiz EOA, Romfh P, Tessier SN. Real-time monitoring of mitochondrial oxygenation during machine perfusion using resonance Raman spectroscopy predicts organ function. RESEARCH SQUARE 2023:rs.3.rs-3740098. [PMID: 38196624 PMCID: PMC10775389 DOI: 10.21203/rs.3.rs-3740098/v1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/11/2024]
Abstract
Organ transplantation is a life-saving procedure affecting over 100,000 people on the transplant waitlist. Ischemia reperfusion injury is a major challenge in the field as it can cause post-transplantation complications and limits the use of organs from extended criteria donors. Machine perfusion technology is used to repair organs before transplant, however, currently fails to achieve its full potential due to a lack of highly sensitive and specific assays to predict organ quality during perfusion. We developed a real-time and non-invasive method of assessing organ function and injury based on mitochondrial oxygenation using resonance Raman spectroscopy. It uses a 441 nm laser and a high-resolution spectrometer to predict the oxidation state of mitochondrial cytochromes during perfusion, which vary due to differences in storage compositions and perfusate compositions. This index of mitochondrial oxidation, or 3RMR, was found to predict organ health based on clinically utilized markers of perfusion quality, tissue metabolism, and organ injury. It also revealed differences in oxygenation with perfusates that may or may not be supplemented with packed red blood cells as oxygen carriers. This study emphasizes the need for further refinement of a reoxygenation strategy during machine perfusion that is based on a gradual recovery from storage. Thus, we present a novel platform that provides a real-time and quantitative assessment of mitochondrial health during machine perfusion of livers, which is easy to translate to the clinic.
Collapse
Affiliation(s)
- Rohil Jain
- Harvard Medical School & Massachusetts General Hospital
| | | | | | | | | |
Collapse
|
5
|
Ozgur OS, Namsrai BE, Pruett TL, Bischof JC, Toner M, Finger EB, Uygun K. Current practice and novel approaches in organ preservation. FRONTIERS IN TRANSPLANTATION 2023; 2:1156845. [PMID: 38993842 PMCID: PMC11235303 DOI: 10.3389/frtra.2023.1156845] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Accepted: 05/16/2023] [Indexed: 07/13/2024]
Abstract
Organ transplantation remains the only treatment option for patients with end-stage organ failure. The last decade has seen a flurry of activity in improving organ preservation technologies, which promise to increase utilization in a dramatic fashion. They also bring the promise of extending the preservation duration significantly, which opens the doors to sharing organs across local and international boundaries and transforms the field. In this work, we review the recent literature on machine perfusion of livers across various protocols in development and clinical use, in the context of extending the preservation duration. We then review the next generation of technologies that have the potential to further extend the limits and open the door to banking organs, including supercooling, partial freezing, and nanowarming, and outline the opportunities arising in the field for researchers in the short and long term.
Collapse
Affiliation(s)
- Ozge Sila Ozgur
- Department of Surgery, Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, United States
- Research Department, Shriners Children’s Boston, Boston, MA, United States
| | - Bat-Erdene Namsrai
- Department of Surgery, University of Minnesota, Minneapolis, MN, United States
| | - Timothy L. Pruett
- Department of Surgery, University of Minnesota, Minneapolis, MN, United States
| | - John C. Bischof
- Departments of Mechanical and Biomedical Engineering, University of Minnesota, Minneapolis, MN, United States
| | - Mehmet Toner
- Department of Surgery, Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, United States
- Research Department, Shriners Children’s Boston, Boston, MA, United States
| | - Erik B. Finger
- Department of Surgery, University of Minnesota, Minneapolis, MN, United States
| | - Korkut Uygun
- Department of Surgery, Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, United States
- Research Department, Shriners Children’s Boston, Boston, MA, United States
| |
Collapse
|
6
|
Goutard M, de Vries RJ, Tawa P, Pendexter CA, Rosales IA, Tessier SN, Burlage LC, Lantieri L, Randolph MA, Lellouch AG, Cetrulo CL, Uygun K. Exceeding the Limits of Static Cold Storage in Limb Transplantation Using Subnormothermic Machine Perfusion. J Reconstr Microsurg 2023; 39:350-360. [PMID: 35764315 PMCID: PMC10848168 DOI: 10.1055/a-1886-5697] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
BACKGROUND For 50 years, static cold storage (SCS) has been the gold standard for solid organ preservation in transplantation. Although logistically convenient, this preservation method presents important constraints in terms of duration and cold ischemia-induced lesions. We aimed to develop a machine perfusion (MP) protocol for recovery of vascularized composite allografts (VCA) after static cold preservation and determine its effects in a rat limb transplantation model. METHODS Partial hindlimbs were procured from Lewis rats and subjected to SCS in Histidine-Tryptophan-Ketoglutarate solution for 0, 12, 18, 24, and 48 hours. They were then either transplanted (Txp), subjected to subnormothermic machine perfusion (SNMP) for 3 hours with a modified Steen solution, or to SNMP + Txp. Perfusion parameters were assessed for blood gas and electrolytes measurement, and flow rate and arterial pressures were monitored continuously. Histology was assessed at the end of perfusion. For select SCS durations, graft survival and clinical outcomes after transplantation were compared between groups at 21 days. RESULTS Transplantation of limbs preserved for 0, 12, 18, and 24-hour SCS resulted in similar survival rates at postoperative day 21. Grafts cold-stored for 48 hours presented delayed graft failure (p = 0.0032). SNMP of limbs after 12-hour SCS recovered the vascular resistance, potassium, and lactate levels to values similar to limbs that were not subjected to SCS. However, 18-hour SCS grafts developed significant edema during SNMP recovery. Transplantation of grafts that had undergone a mixed preservation method (12-hour SCS + SNMP + Txp) resulted in better clinical outcomes based on skin clinical scores at day 21 post-transplantation when compared to the SCS + Txp group (p = 0.01613). CONCLUSION To date, VCA MP is still limited to animal models and no protocols are yet developed for graft recovery. Our study suggests that ex vivo SNMP could help increase the preservation duration and limit cold ischemia-induced injury in VCA transplantation.
Collapse
Affiliation(s)
- Marion Goutard
- Division of Plastic Surgery, Massachusetts General Hospital, Boston, Massachusetts
- Department of Surgery, Harvard Medical School, Harvard Medical School, Boston, Massachusetts
- Department of Research, Shriners Children’s, Boston, Massachusetts
- Service de Chirurgie Plastique, Hôpital Européen Georges Pompidou, Assistance Publique-Hôpitaux de Paris (APHP), Université Paris Descartes, Paris, France
| | - Reinier J. de Vries
- Department of Surgery, Harvard Medical School, Harvard Medical School, Boston, Massachusetts
- Department of Research, Shriners Children’s, Boston, Massachusetts
- Department of Surgery, Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Boston, Massachusetts
- Department of Surgery, Amsterdam University Medical Centers – location AMC, University of Amsterdam, Amsterdam, the Netherlands
| | - Pierre Tawa
- Division of Plastic Surgery, Massachusetts General Hospital, Boston, Massachusetts
- Department of Surgery, Harvard Medical School, Harvard Medical School, Boston, Massachusetts
- Department of Research, Shriners Children’s, Boston, Massachusetts
| | - Casie A. Pendexter
- Department of Surgery, Harvard Medical School, Harvard Medical School, Boston, Massachusetts
- Department of Research, Shriners Children’s, Boston, Massachusetts
- Department of Surgery, Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Boston, Massachusetts
| | - Ivy A. Rosales
- Immunopathology Research Laboratory, Center for Transplantation Sciences, Massachusetts General Hospital, Boston, Massachusetts
| | - Shannon N. Tessier
- Department of Surgery, Harvard Medical School, Harvard Medical School, Boston, Massachusetts
- Department of Research, Shriners Children’s, Boston, Massachusetts
- Department of Surgery, Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Boston, Massachusetts
| | - Laura C. Burlage
- Division of Plastic Surgery, Massachusetts General Hospital, Boston, Massachusetts
- Department of Surgery, Harvard Medical School, Harvard Medical School, Boston, Massachusetts
- Department of Research, Shriners Children’s, Boston, Massachusetts
- Department of Surgery, University Medical Center Groningen, Groningen, the Netherlands
- Division of Plastic and Reconstructive Surgery within the Department of Surgery, Radboudumc, Radboud University, Nijmegen, the Netherlands
| | - Laurent Lantieri
- Service de Chirurgie Plastique, Hôpital Européen Georges Pompidou, Assistance Publique-Hôpitaux de Paris (APHP), Université Paris Descartes, Paris, France
| | - Mark A. Randolph
- Division of Plastic Surgery, Massachusetts General Hospital, Boston, Massachusetts
- Department of Surgery, Harvard Medical School, Harvard Medical School, Boston, Massachusetts
- Department of Research, Shriners Children’s, Boston, Massachusetts
| | - Alexandre G. Lellouch
- Division of Plastic Surgery, Massachusetts General Hospital, Boston, Massachusetts
- Department of Surgery, Harvard Medical School, Harvard Medical School, Boston, Massachusetts
- Department of Research, Shriners Children’s, Boston, Massachusetts
- Service de Chirurgie Plastique, Hôpital Européen Georges Pompidou, Assistance Publique-Hôpitaux de Paris (APHP), Université Paris Descartes, Paris, France
| | - Curtis L. Cetrulo
- Division of Plastic Surgery, Massachusetts General Hospital, Boston, Massachusetts
- Department of Surgery, Harvard Medical School, Harvard Medical School, Boston, Massachusetts
- Department of Research, Shriners Children’s, Boston, Massachusetts
| | - Korkut Uygun
- Department of Surgery, Harvard Medical School, Harvard Medical School, Boston, Massachusetts
- Department of Research, Shriners Children’s, Boston, Massachusetts
- Department of Surgery, Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Boston, Massachusetts
| |
Collapse
|
7
|
Lucia A, Uygun K. Optimal Temperature Protocols for Liver Machine Perfusion Using a Monte Carlo Method. IFAC-PAPERSONLINE 2023; 55:35-40. [PMID: 38410830 PMCID: PMC10895677 DOI: 10.1016/j.ifacol.2023.01.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 02/28/2024]
Abstract
Monte Carlo simulation with a novel acceptance procedure is used to find optimal temperature profiles for liver machine perfusion. Numerical results for MC simulation are compared to a greedy approach and to current practice in machine perfusion research. Results show that the proposed Monte Carlo simulation approach finds optimal temperature profiles that agree with current clinical research practice.
Collapse
Affiliation(s)
- Angelo Lucia
- University of Rhode Island, Kingston, RI 02881-2019 USA
| | - Korkut Uygun
- Massachusetts General Hospital, Boston, MA 02114 USA
| |
Collapse
|
8
|
Muth V, Gassner JMGV, Moosburner S, Lurje G, Michelotto J, Strobl F, Knaub K, Engelmann C, Tacke F, Selzner M, Pratschke J, Sauer IM, Raschzok N. Ex Vivo Liver Machine Perfusion: Comprehensive Review of Common Animal Models. TISSUE ENGINEERING. PART B, REVIEWS 2023; 29:10-27. [PMID: 35848526 DOI: 10.1089/ten.teb.2022.0018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
The most common preservation technique for liver grafts is static cold storage. Due to the organ shortage for liver transplantation (LT), extended criteria donor (ECD) allografts are increasingly used-despite the higher risk of inferior outcome after transplantation. Ex vivo liver machine perfusion (MP) has been developed to improve the outcome of transplantation, especially with ECD grafts, and is currently under evaluation in clinical trials. We performed a literature search on PubMed and ISI Web of Science to assemble an overview of rodent and porcine animal models of ex vivo liver MP for transplantation, which is essential for the present and future development of clinical liver MP. Hypothermic, subnormothermic, and normothermic MP systems have been successfully used for rat and pig LT. In comparison with hypothermic systems, normothermic perfusion often incorporates a dialysis unit. Moreover, it enables metabolic assessment of liver grafts. Allografts experiencing warm ischemic time have a superior survival rate after MP compared with cold storage alone, irrespective of the temperature used for perfusion. Furthermore, ex vivo MP improves the outcome of regular and ECD liver grafts in animal models. Small and large animal models of ex vivo liver MP are available to foster the further development of this new technology. Impact Statement Ex vivo machine perfusion is an important part of current research in the field of liver transplantation. While evidence for improve storage is constantly rising, the development of future applications such as quality assessment and therapeutic interventions necessitates robust animal models. This review is intended to provide an overview of this technology in common large and small animal models and to give an outlook on future applications. Moreover, we describe developmental steps that can be followed by others, and which can help to decrease the number of animals used for experiments based on the replace, reduce, refine concept.
Collapse
Affiliation(s)
- Vanessa Muth
- Department of Surgery, Experimental Surgery, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Joseph M G V Gassner
- Department of Surgery, Experimental Surgery, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany.,Clinician Scientist Program, BIH Academy, Berlin Institute of Health at Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Simon Moosburner
- Department of Surgery, Experimental Surgery, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany.,Clinician Scientist Program, BIH Academy, Berlin Institute of Health at Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Georg Lurje
- Department of Surgery, Experimental Surgery, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Julian Michelotto
- Department of Surgery, Experimental Surgery, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Felix Strobl
- Department of Surgery, Experimental Surgery, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Kristina Knaub
- Department of Surgery, Experimental Surgery, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Cornelius Engelmann
- Department of Hepatology and Gastroenterology, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Frank Tacke
- Department of Hepatology and Gastroenterology, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Markus Selzner
- Department of Surgery, Abdominal Transplant and HPB Surgery, Ajmera Family Transplant Centre, Toronto General Hospital, Toronto, Canada
| | - Johann Pratschke
- Department of Surgery, Experimental Surgery, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Igor M Sauer
- Department of Surgery, Experimental Surgery, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Nathanael Raschzok
- Department of Surgery, Experimental Surgery, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany.,Clinician Scientist Program, BIH Academy, Berlin Institute of Health at Charité-Universitätsmedizin Berlin, Berlin, Germany
| |
Collapse
|
9
|
A Meta-Analysis and Systematic Review of Normothermic and Hypothermic Machine Perfusion in Liver Transplantation. J Clin Med 2022; 12:jcm12010235. [PMID: 36615037 PMCID: PMC9820958 DOI: 10.3390/jcm12010235] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Revised: 12/02/2022] [Accepted: 12/05/2022] [Indexed: 12/30/2022] Open
Abstract
BACKGROUND The gap between the demand and supply of donor livers is still a considerable challenge. Since static cold storage is not sufficient in marginal livers, machine perfusion is being explored as an alternative. The objective of this study was to assess (dual) hypothermic oxygenated machine perfusion (HOPE/D-HOPE) and normothermic machine perfusion (NMP) in contrast to static cold storage (SCS). METHODS Three databases were searched to identify studies about machine perfusion. Graft and patient survival and postoperative complications were evaluated using the random effects model. RESULTS the incidence of biliary complications was lower in HOPE vs. SCS (OR: 0.59, 95% CI: 0.36-0.98, p = 0.04, I2: 0%). There was no significant difference in biliary complications between NMP and SCS (OR: 0.76, 95% CI: 0.41-1.40, p = 0.38, I2: 55%). Graft and patient survival were significantly better in HOPE than in SCS (HR: 0.40, 95% CI: 0.23-0.71, p = 0.002, I2: 0%) and (pooled HR: 0.43, 95% CI: 0.20-0.93, p = 0.03, I2: 0%). Graft and patient survival were not significantly different between NMP and SCS. CONCLUSION HOPE/D-HOPE and NMP are promising alternatives to SCS for donor liver preservation. They may help address the widening gap between the demand for and availability of donor livers by enabling the rescue and transplantation of marginal livers.
Collapse
|
10
|
Tessier SN, de Vries RJ, Pendexter CA, Cronin SEJ, Ozer S, Hafiz EOA, Raigani S, Oliveira-Costa JP, Wilks BT, Lopera Higuita M, van Gulik TM, Usta OB, Stott SL, Yeh H, Yarmush ML, Uygun K, Toner M. Partial freezing of rat livers extends preservation time by 5-fold. Nat Commun 2022; 13:4008. [PMID: 35840553 PMCID: PMC9287450 DOI: 10.1038/s41467-022-31490-2] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Accepted: 06/20/2022] [Indexed: 02/04/2023] Open
Abstract
The limited preservation duration of organs has contributed to the shortage of organs for transplantation. Recently, a tripling of the storage duration was achieved with supercooling, which relies on temperatures between -4 and -6 °C. However, to achieve deeper metabolic stasis, lower temperatures are required. Inspired by freeze-tolerant animals, we entered high-subzero temperatures (-10 to -15 °C) using ice nucleators to control ice and cryoprotective agents (CPAs) to maintain an unfrozen liquid fraction. We present this approach, termed partial freezing, by testing gradual (un)loading and different CPAs, holding temperatures, and storage durations. Results indicate that propylene glycol outperforms glycerol and injury is largely influenced by storage temperatures. Subsequently, we demonstrate that machine perfusion enhancements improve the recovery of livers after freezing. Ultimately, livers that were partially frozen for 5-fold longer showed favorable outcomes as compared to viable controls, although frozen livers had lower cumulative bile and higher liver enzymes.
Collapse
Affiliation(s)
- Shannon N. Tessier
- grid.38142.3c000000041936754XCenter for Engineering in Medicine and Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, MA USA ,grid.415829.30000 0004 0449 5362Shriners Hospitals for Children Boston, Boston, MA USA
| | - Reinier J. de Vries
- grid.38142.3c000000041936754XCenter for Engineering in Medicine and Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, MA USA ,grid.415829.30000 0004 0449 5362Shriners Hospitals for Children Boston, Boston, MA USA ,grid.7177.60000000084992262Department of Surgery, Amsterdam University Medical Centers – location AMC, University of Amsterdam, Amsterdam, the Netherlands
| | - Casie A. Pendexter
- grid.38142.3c000000041936754XCenter for Engineering in Medicine and Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, MA USA ,grid.415829.30000 0004 0449 5362Shriners Hospitals for Children Boston, Boston, MA USA ,Present Address: Sylvatica Biotech Inc., North Charleston, SC USA
| | - Stephanie E. J. Cronin
- grid.38142.3c000000041936754XCenter for Engineering in Medicine and Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, MA USA ,grid.415829.30000 0004 0449 5362Shriners Hospitals for Children Boston, Boston, MA USA
| | - Sinan Ozer
- grid.38142.3c000000041936754XCenter for Engineering in Medicine and Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, MA USA ,grid.415829.30000 0004 0449 5362Shriners Hospitals for Children Boston, Boston, MA USA
| | - Ehab O. A. Hafiz
- grid.420091.e0000 0001 0165 571XDepartment of Electron Microscopy Research, Theodor Bilharz Research Institute, Giza, Egypt
| | - Siavash Raigani
- grid.415829.30000 0004 0449 5362Shriners Hospitals for Children Boston, Boston, MA USA ,grid.32224.350000 0004 0386 9924Department of Surgery, Division of Transplantation, Massachusetts General Hospital, Boston, MA USA
| | - Joao Paulo Oliveira-Costa
- grid.38142.3c000000041936754XCenter for Engineering in Medicine and Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, MA USA ,grid.38142.3c000000041936754XDepartment of Medicine and Cancer Center, Massachusetts General Hospital, Harvard Medical School, Charlestown, MA USA
| | - Benjamin T. Wilks
- grid.38142.3c000000041936754XCenter for Engineering in Medicine and Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, MA USA ,grid.415829.30000 0004 0449 5362Shriners Hospitals for Children Boston, Boston, MA USA
| | - Manuela Lopera Higuita
- grid.38142.3c000000041936754XCenter for Engineering in Medicine and Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, MA USA ,grid.415829.30000 0004 0449 5362Shriners Hospitals for Children Boston, Boston, MA USA
| | - Thomas M. van Gulik
- grid.7177.60000000084992262Department of Surgery, Amsterdam University Medical Centers – location AMC, University of Amsterdam, Amsterdam, the Netherlands
| | - Osman Berk Usta
- grid.38142.3c000000041936754XCenter for Engineering in Medicine and Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, MA USA ,grid.415829.30000 0004 0449 5362Shriners Hospitals for Children Boston, Boston, MA USA
| | - Shannon L. Stott
- grid.38142.3c000000041936754XCenter for Engineering in Medicine and Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, MA USA ,grid.38142.3c000000041936754XDepartment of Medicine and Cancer Center, Massachusetts General Hospital, Harvard Medical School, Charlestown, MA USA
| | - Heidi Yeh
- grid.32224.350000 0004 0386 9924Department of Surgery, Division of Transplantation, Massachusetts General Hospital, Boston, MA USA
| | - Martin L. Yarmush
- grid.38142.3c000000041936754XCenter for Engineering in Medicine and Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, MA USA ,grid.415829.30000 0004 0449 5362Shriners Hospitals for Children Boston, Boston, MA USA ,grid.430387.b0000 0004 1936 8796Department of Biomedical Engineering, Rutgers University, Piscataway, NJ USA
| | - Korkut Uygun
- grid.38142.3c000000041936754XCenter for Engineering in Medicine and Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, MA USA ,grid.415829.30000 0004 0449 5362Shriners Hospitals for Children Boston, Boston, MA USA
| | - Mehmet Toner
- grid.38142.3c000000041936754XCenter for Engineering in Medicine and Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, MA USA ,grid.415829.30000 0004 0449 5362Shriners Hospitals for Children Boston, Boston, MA USA
| |
Collapse
|
11
|
Lucia A, Ferrarese E, Uygun K. Modeling energy depletion in rat livers using Nash equilibrium metabolic pathway analysis. Sci Rep 2022; 12:3496. [PMID: 35241684 PMCID: PMC8894355 DOI: 10.1038/s41598-022-06966-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2021] [Accepted: 02/08/2022] [Indexed: 11/16/2022] Open
Abstract
The current gold standard of Static Cold Storage (SCS), which is static cold storage on ice (about + 4 °C) in a specialized media such as the University of Wisconsin solution (UW), limits storage to few hours for vascular and metabolically active tissues such as the liver and the heart. The liver is arguably the pinnacle of metabolism in human body and therefore metabolic pathway analysis immediately becomes very relevant. In this article, a Nash Equilibrium (NE) approach, which is a first principles approach, is used to model and simulate the static cold storage and warm ischemia of a proposed model of liver cells. Simulations of energy depletion in the liver in static cold storage measured by ATP content and energy charge are presented along with comparisons to experimental data. In addition, conversion of Nash Equilibrium iterations to time are described along with an uncertainty analysis for the parameters in the model. Results in this work show that the Nash Equilibrium approach provides a good match to experimental data for energy depletion and that the uncertainty in model parameters is very small with percent variances less than 0.1%.
Collapse
Affiliation(s)
- Angelo Lucia
- Department of Chemical Engineering, University of Rhode Island, Kington, RI, 02881, USA.
| | - Emily Ferrarese
- Department of Chemical Engineering, University of Rhode Island, Kington, RI, 02881, USA
| | - Korkut Uygun
- Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Boston, MA, 02114, USA
| |
Collapse
|
12
|
de Vries RJ, Cronin SEJ, Romfh P, Pendexter CA, Jain R, Wilks BT, Raigani S, van Gulik TM, Chen P, Yeh H, Uygun K, Tessier SN. Non-invasive quantification of the mitochondrial redox state in livers during machine perfusion. PLoS One 2021; 16:e0258833. [PMID: 34705828 PMCID: PMC8550443 DOI: 10.1371/journal.pone.0258833] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Accepted: 10/06/2021] [Indexed: 11/19/2022] Open
Abstract
Ischemia reperfusion injury (IRI) is a critical problem in liver transplantation that can lead to life-threatening complications and substantially limit the utilization of livers for transplantation. However, because there are no early diagnostics available, fulminant injury may only become evident post-transplant. Mitochondria play a central role in IRI and are an ideal diagnostic target. During ischemia, changes in the mitochondrial redox state form the first link in the chain of events that lead to IRI. In this study we used resonance Raman spectroscopy to provide a rapid, non-invasive, and label-free diagnostic for quantification of the hepatic mitochondrial redox status. We show this diagnostic can be used to significantly distinguish transplantable versus non-transplantable ischemically injured rat livers during oxygenated machine perfusion and demonstrate spatial differences in the response of mitochondrial redox to ischemia reperfusion. This novel diagnostic may be used in the future to predict the viability of human livers for transplantation and as a tool to better understand the mechanisms of hepatic IRI.
Collapse
Affiliation(s)
- Reinier J. de Vries
- Center for Engineering in Medicine and Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, MA, United States of America
- Shriners Hospitals for Children—Boston, Boston, MA, United States of America
- Department of Surgery, Amsterdam University Medical Centers–Location AMC, University of Amsterdam, Amsterdam, the Netherlands
| | - Stephanie E. J. Cronin
- Center for Engineering in Medicine and Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, MA, United States of America
- Shriners Hospitals for Children—Boston, Boston, MA, United States of America
| | - Padraic Romfh
- Pendar Technologies, Cambridge, MA, United States of America
| | - Casie A. Pendexter
- Center for Engineering in Medicine and Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, MA, United States of America
- Shriners Hospitals for Children—Boston, Boston, MA, United States of America
| | - Rohil Jain
- Center for Engineering in Medicine and Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, MA, United States of America
- Shriners Hospitals for Children—Boston, Boston, MA, United States of America
| | - Benjamin T. Wilks
- Center for Engineering in Medicine and Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, MA, United States of America
- Shriners Hospitals for Children—Boston, Boston, MA, United States of America
| | - Siavash Raigani
- Center for Engineering in Medicine and Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, MA, United States of America
- Shriners Hospitals for Children—Boston, Boston, MA, United States of America
- Division of Transplantation, Department of Surgery, Massachusetts General Hospital, Boston, MA, United States of America
| | - Thomas M. van Gulik
- Department of Surgery, Amsterdam University Medical Centers–Location AMC, University of Amsterdam, Amsterdam, the Netherlands
| | - Peili Chen
- Pendar Technologies, Cambridge, MA, United States of America
| | - Heidi Yeh
- Division of Transplantation, Department of Surgery, Massachusetts General Hospital, Boston, MA, United States of America
| | - Korkut Uygun
- Center for Engineering in Medicine and Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, MA, United States of America
- Shriners Hospitals for Children—Boston, Boston, MA, United States of America
| | - Shannon N. Tessier
- Center for Engineering in Medicine and Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, MA, United States of America
- Shriners Hospitals for Children—Boston, Boston, MA, United States of America
| |
Collapse
|
13
|
Nida S, Moses JA, Anandharamakrishnan C. Isochoric Freezing and Its Emerging Applications in Food Preservation. FOOD ENGINEERING REVIEWS 2021. [DOI: 10.1007/s12393-021-09284-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
14
|
Cell release during perfusion reflects cold ischemic injury in rat livers. Sci Rep 2020; 10:1102. [PMID: 31980677 PMCID: PMC6981218 DOI: 10.1038/s41598-020-57589-4] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2019] [Accepted: 12/28/2019] [Indexed: 12/13/2022] Open
Abstract
The global shortage of donor organs has made it crucial to deeply understand and better predict donor liver viability. However, biomarkers that effectively assess viability of marginal grafts for organ transplantation are currently lacking. Here, we showed that hepatocytes, sinusoidal endothelial, stellate, and liver-specific immune cells were released into perfusates from Lewis rat livers as a result of cold ischemia and machine perfusion. Perfusate comparison analysis of fresh livers and cold ischemic livers showed that the released cell profiles were significantly altered by the duration of cold ischemia. Our findings show for the first time that parenchymal cells are released from organs under non-proliferative pathological conditions, correlating with the degree of ischemic injury. Thus, perfusate cell profiles could serve as potential biomarkers of graft viability and indicators of specific injury mechanisms during organ handling and transplantation. Further, parenchymal cell release may have applications in other pathological conditions beyond organ transplantation.
Collapse
|
15
|
Human Red Blood Cells as Oxygen Carriers to Improve Ex-Situ Liver Perfusion in a Rat Model. J Clin Med 2019; 8:jcm8111918. [PMID: 31717387 PMCID: PMC6912657 DOI: 10.3390/jcm8111918] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2019] [Revised: 11/03/2019] [Accepted: 11/05/2019] [Indexed: 12/11/2022] Open
Abstract
Ex-situ machine perfusion (MP) has been increasingly used to enhance liver quality in different settings. Small animal models can help to implement this procedure. As most normothermic MP (NMP) models employ sub-physiological levels of oxygen delivery (DO2), the aim of this study was to investigate the effectiveness and safety of different DO2, using human red blood cells (RBCs) as oxygen carriers on metabolic recovery in a rat model of NMP. Four experimental groups (n = 5 each) consisted of (1) native (untreated/control), (2) liver static cold storage (SCS) 30 min without NMP, (3) SCS followed by 120 min of NMP with Dulbecco-Modified-Eagle-Medium as perfusate (DMEM), and (4) similar to group 3, but perfusion fluid was added with human RBCs (hematocrit 15%) (BLOOD). Compared to DMEM, the BLOOD group showed increased liver DO2 (p = 0.008) and oxygen consumption ( V O ˙ 2) (p < 0.001); lactate clearance (p < 0.001), potassium (p < 0.001), and glucose (p = 0.029) uptake were enhanced. ATP levels were likewise higher in BLOOD relative to DMEM (p = 0.031). V O ˙ 2 and DO2 were highly correlated (p < 0.001). Consistently, the main metabolic parameters were directly correlated with DO2 and V O ˙ 2. No human RBC related damage was detected. In conclusion, an optimized DO2 significantly reduces hypoxic damage-related effects occurring during NMP. Human RBCs can be safely used as oxygen carriers.
Collapse
|
16
|
Abstract
Machine perfusion is a hot topic in liver transplantation and several new perfusion concepts are currently developed. Prior to introduction into routine clinical practice, however, such perfusion approaches need to demonstrate their impact on liver function, post-transplant complications, utilization rates of high-risk organs, and cost benefits. Therefore, based on results of experimental and clinical studies, the community has to recognize the limitations of this technology. In this review, we summarize current perfusion concepts and differences between protective mechanisms of ex- and in-situ perfusion techniques. Next, we discuss which graft types may benefit most from perfusion techniques, and highlight the current understanding of liver viability testing. Finally, we present results from recent clinical trials involving machine liver perfusion, and analyze the value of different outcome parameters, currently used as endpoints for randomized controlled trials in the field.
Collapse
Affiliation(s)
- Andrea Schlegel
- Liver Unit, Queen Elizabeth Hospital, University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK.,Centre for Liver and Gastrointestinal Research, Institute of Immunology and Immunotherapy, College of Medical and Dental Sciences, University of Birmingham, Birmingham, UK.,Department of Surgery and Transplantation, University Hospital Zurich, Zurich, Switzerland
| | - Xavier Muller
- Department of Surgery and Transplantation, University Hospital Zurich, Zurich, Switzerland
| | - Philipp Dutkowski
- Department of Surgery and Transplantation, University Hospital Zurich, Zurich, Switzerland
| |
Collapse
|
17
|
de Vries RJ, Tessier SN, Banik PD, Nagpal S, Cronin SEJ, Ozer S, Hafiz EOA, van Gulik TM, Yarmush ML, Markmann JF, Toner M, Yeh H, Uygun K. Supercooling extends preservation time of human livers. Nat Biotechnol 2019; 37:1131-1136. [PMID: 31501557 PMCID: PMC6776681 DOI: 10.1038/s41587-019-0223-y] [Citation(s) in RCA: 109] [Impact Index Per Article: 21.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2018] [Accepted: 07/12/2019] [Indexed: 12/25/2022]
Abstract
The inability to preserve vascular organs beyond several hours contributes to the scarcity of organs for transplantation1,2. Standard hypothermic preservation at +4 °C (refs. 1,3) limits liver preservation to less than 12 h. Our group previously showed that supercooled ice-free storage at -6 °C can extend viable preservation of rat livers4,5 However, scaling supercooling preservation to human organs is intrinsically limited because of volume-dependent stochastic ice formation. Here, we describe an improved supercooling protocol that averts freezing of human livers by minimizing favorable sites of ice nucleation and homogeneous preconditioning with protective agents during machine perfusion. We show that human livers can be stored at -4 °C with supercooling followed by subnormothermic machine perfusion, effectively extending the ex vivo life of the organ by 27 h. We show that viability of livers before and after supercooling is unchanged, and that after supercooling livers can withstand the stress of simulated transplantation by ex vivo normothermic reperfusion with blood.
Collapse
Affiliation(s)
- Reinier J de Vries
- Center for Engineering in Medicine, Harvard Medical School & Massachusetts General Hospital, Boston, MA, USA
- Department of Surgery, University of Amsterdam, Amsterdam, the Netherlands
- Shriners Hospital for Children, Boston, MA, USA
| | - Shannon N Tessier
- Center for Engineering in Medicine, Harvard Medical School & Massachusetts General Hospital, Boston, MA, USA
- Shriners Hospital for Children, Boston, MA, USA
| | - Peony D Banik
- Center for Engineering in Medicine, Harvard Medical School & Massachusetts General Hospital, Boston, MA, USA
- Shriners Hospital for Children, Boston, MA, USA
| | - Sonal Nagpal
- Center for Engineering in Medicine, Harvard Medical School & Massachusetts General Hospital, Boston, MA, USA
- Shriners Hospital for Children, Boston, MA, USA
| | - Stephanie E J Cronin
- Center for Engineering in Medicine, Harvard Medical School & Massachusetts General Hospital, Boston, MA, USA
- Shriners Hospital for Children, Boston, MA, USA
| | - Sinan Ozer
- Center for Engineering in Medicine, Harvard Medical School & Massachusetts General Hospital, Boston, MA, USA
- Shriners Hospital for Children, Boston, MA, USA
| | - Ehab O A Hafiz
- Center for Engineering in Medicine, Harvard Medical School & Massachusetts General Hospital, Boston, MA, USA
- Shriners Hospital for Children, Boston, MA, USA
- Department of Electron Microscopy Research, Theodor Bilharz Research Institute, Giza, Egypt
| | - Thomas M van Gulik
- Department of Surgery, University of Amsterdam, Amsterdam, the Netherlands
| | - Martin L Yarmush
- Center for Engineering in Medicine, Harvard Medical School & Massachusetts General Hospital, Boston, MA, USA
- Shriners Hospital for Children, Boston, MA, USA
| | - James F Markmann
- Center for Engineering in Medicine, Harvard Medical School & Massachusetts General Hospital, Boston, MA, USA
- Center for Transplant Sciences, Massachusetts General Hospital, Boston, MA, USA
| | - Mehmet Toner
- Center for Engineering in Medicine, Harvard Medical School & Massachusetts General Hospital, Boston, MA, USA
- Shriners Hospital for Children, Boston, MA, USA
| | - Heidi Yeh
- Center for Engineering in Medicine, Harvard Medical School & Massachusetts General Hospital, Boston, MA, USA
- Center for Transplant Sciences, Massachusetts General Hospital, Boston, MA, USA
| | - Korkut Uygun
- Center for Engineering in Medicine, Harvard Medical School & Massachusetts General Hospital, Boston, MA, USA.
- Shriners Hospital for Children, Boston, MA, USA.
| |
Collapse
|
18
|
Bellini MI, Yiu J, Nozdrin M, Papalois V. The Effect of Preservation Temperature on Liver, Kidney, and Pancreas Tissue ATP in Animal and Preclinical Human Models. J Clin Med 2019; 8:jcm8091421. [PMID: 31505880 PMCID: PMC6780500 DOI: 10.3390/jcm8091421] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2019] [Revised: 08/30/2019] [Accepted: 09/02/2019] [Indexed: 02/06/2023] Open
Abstract
The recent advances in machine perfusion (MP) technology involve settings ranging between hypothermic, subnormothermic, and normothermic temperatures. Tissue level adenosine triphosphate (ATP) is a long-established marker of viability and functionality and is universal for all organs. In the midst of a growing number of complex clinical parameters for the quality assessment of graft prior to transplantation, a revisit of ATP may shed light on the underlying reconditioning mechanisms of different perfusion temperatures in the form of restoration of metabolic and energy status. This article aims to review and critically analyse animal and preclinical human studies (discarded grafts) during MP of three abdominal organs (liver, kidney, and pancreas) in which ATP was a primary endpoint. A selective review of recent novel reconditioning approaches relevant to mitigation of graft ischaemia-reperfusion injury via MP and for different perfusion temperatures was also conducted. With a current reiterated interest for oxygenation during MP, a re-introduction of tissue ATP levels may be valuable for graft viability assessment prior to transplantation. Further studies may help delineate the benefits of selective perfusion temperatures on organs viability.
Collapse
Affiliation(s)
| | - Janice Yiu
- School of Medicine, University College London, London WC1E 6BT, UK
| | - Mikhail Nozdrin
- School of Medicine, Imperial College London, London SW72AZ, UK
| | - Vassilios Papalois
- Renal and Transplant Directorate, Imperial College Healthcare NHS Trust, London W120HS, UK
- Department of Surgery and Cancer, Imperial College London, London SW72AZ, UK
| |
Collapse
|
19
|
de Vries RJ, Yarmush M, Uygun K. Systems engineering the organ preservation process for transplantation. Curr Opin Biotechnol 2019; 58:192-201. [PMID: 31280087 PMCID: PMC7261508 DOI: 10.1016/j.copbio.2019.05.015] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2019] [Revised: 04/29/2019] [Accepted: 05/27/2019] [Indexed: 12/23/2022]
Abstract
Improving organ preservation and extending the preservation time would have game-changing effects on the current practice of organ transplantation. Machine perfusion has emerged as an improved preservation technology to expand the donor pool, assess graft viability and ensure adequate graft function. However, its efficacy in extending the preservation time is limited. Subzero organ preservation does hold the promise to significantly extend the preservation time and recent advances in cryobiology bring it closer to clinical translation. In this review, we aim to broaden the perspective in the field from a focus on these individual technologies to that of a systems engineering. This would enable the creation of a preservation process that integrates the benefits of machine perfusion with those of subzero preservation, with the ultimate goal to provide on demand availability of donor organs through organ banking.
Collapse
Affiliation(s)
- Reinier J de Vries
- Center for Engineering in Medicine, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA; Shriners Hospital for Children, Boston, MA, USA; Department of Surgery, University of Amsterdam, Amsterdam, The Netherlands
| | - Martin Yarmush
- Center for Engineering in Medicine, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA; Shriners Hospital for Children, Boston, MA, USA; Department of Biomedical Engineering, Rutgers University, New Brunswick, NJ, USA
| | - Korkut Uygun
- Center for Engineering in Medicine, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA; Shriners Hospital for Children, Boston, MA, USA.
| |
Collapse
|
20
|
Taylor MJ, Weegman BP, Baicu SC, Giwa SE. New Approaches to Cryopreservation of Cells, Tissues, and Organs. Transfus Med Hemother 2019; 46:197-215. [PMID: 31244588 PMCID: PMC6558330 DOI: 10.1159/000499453] [Citation(s) in RCA: 94] [Impact Index Per Article: 18.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2019] [Accepted: 03/07/2019] [Indexed: 12/11/2022] Open
Abstract
In this concept article, we outline a variety of new approaches that have been conceived to address some of the remaining challenges for developing improved methods of biopreservation. This recognizes a true renaissance and variety of complimentary, high-potential approaches leveraging inspiration by nature, nanotechnology, the thermodynamics of pressure, and several other key fields. Development of an organ and tissue supply chain that can meet the healthcare demands of the 21st century means overcoming twin challenges of (1) having enough of these lifesaving resources and (2) having the means to store and transport them for a variety of applications. Each has distinct but overlapping logistical limitations affecting transplantation, regenerative medicine, and drug discovery, with challenges shared among major areas of biomedicine including tissue engineering, trauma care, transfusion medicine, and biomedical research. There are several approaches to biopreservation, the optimum choice of which is dictated by the nature and complexity of the tissue and the required length of storage. Short-term hypothermic storage at temperatures a few degrees above the freezing point has provided the basis for nearly all methods of preserving tissues and solid organs that, to date, have proved refractory to cryopreservation techniques successfully developed for single-cell systems. In essence, these short-term techniques have been based on designing solutions for cellular protection against the effects of warm and cold ischemia and basically rely upon the protective effects of reduced temperatures brought about by Arrhenius kinetics of chemical reactions. However, further optimization of such preservation strategies is now seen to be restricted. Long-term preservation calls for much lower temperatures and requires the tissue to withstand the rigors of heat and mass transfer during protocols designed to optimize cooling and warming in the presence of cryoprotective agents. It is now accepted that with current methods of cryopreservation, uncontrolled ice formation in structured tissues and organs at subzero temperatures is the single most critical factor that severely restricts the extent to which tissues can survive procedures involving freezing and thawing. In recent years, this major problem has been effectively circumvented in some tissues by using ice-free cryopreservation techniques based upon vitrification. Nevertheless, despite these promising advances there remain several recognized hurdles to be overcome before deep-subzero cryopreservation, either by classic freezing and thawing or by vitrification, can provide the much-needed means for biobanking complex tissues and organs for extended periods of weeks, months, or even years. In many cases, the approaches outlined here, including new underexplored paradigms of high-subzero preservation, are novel and inspired by mechanisms of freeze tolerance, or freeze avoidance, in nature. Others apply new bioengineering techniques such as nanotechnology, isochoric pressure preservation, and non-Newtonian fluids to circumvent currently intractable problems in cryopreservation.
Collapse
Affiliation(s)
- Michael J. Taylor
- Sylvatica Biotech, Inc., North Charleston, South Carolina, USA
- Department of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, Pennsylvania, USA
- Department of Medicine, University of Arizona, Tucson, Arizona, USA
| | | | - Simona C. Baicu
- Sylvatica Biotech, Inc., North Charleston, South Carolina, USA
| | | |
Collapse
|
21
|
Knecht C, Balaban CL, Rodríguez JV, Ceccarelli EA, Guibert EE, Rosano GL. Proteome variation of the rat liver after static cold storage assayed in an ex vivo model. Cryobiology 2018; 85:47-55. [PMID: 30296410 DOI: 10.1016/j.cryobiol.2018.10.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2018] [Revised: 10/03/2018] [Accepted: 10/03/2018] [Indexed: 12/28/2022]
Abstract
Cold storage is a common procedure for liver preservation in a transplant setting. However, during cold ischemia, the liver suffers molecular alterations that can affect its performance. Also, deleterious mechanisms set forth in the storage phase are exacerbated during reperfusion. This study aimed to identify liver proteins associated with injury during cold storage and/or normothermic reperfusion using the isolated perfused rat liver model. Livers from male rats were subjected to either (1) cold storage for 24 h, (2) ex vivo normothermic reperfusion for 90 min or (3) cold storage for 24 h followed by ex vivo normothermic reperfusion for 90 min. Then, the livers were homogenized and proteins were extracted. Protein expression between each experimental group and the control (freshly resected livers) was compared by two-dimensional (2D) gel electrophoresis. Protein identification was carried out by matrix-assisted laser desorption/ionization time-of-flight spectrometry (MALDI-TOF/TOF) using MASCOT as the search engine. 23 proteins were detected with significantly altered levels of expression among the different treatments, including molecular chaperones, antioxidant enzymes, and proteins involved in energy metabolism. Some of them have been postulated as biomarkers for liver damage while others had been identified in other organs subjected to ischemia and reperfusion injury. The whole data set will be a useful resource for studying deleterious molecular mechanisms that result in diminished liver function during storage and subsequent reperfusion.
Collapse
Affiliation(s)
- Camila Knecht
- Instituto de Biología Molecular y Celular de Rosario (IBR), Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Facultad de Ciencias Bioquímicas y Farmacéuticas, Universidad Nacional de Rosario, Rosario, 2000, Argentina; Centro Binacional (Argentina-Italia) de Investigaciones en Criobiología Clínica y Aplicada (CAIC), Universidad Nacional de Rosario, Rosario, 2000, Argentina.
| | - Cecilia L Balaban
- Instituto de Biología Molecular y Celular de Rosario (IBR), Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Facultad de Ciencias Bioquímicas y Farmacéuticas, Universidad Nacional de Rosario, Rosario, 2000, Argentina; Centro Binacional (Argentina-Italia) de Investigaciones en Criobiología Clínica y Aplicada (CAIC), Universidad Nacional de Rosario, Rosario, 2000, Argentina.
| | - Joaquín V Rodríguez
- Centro Binacional (Argentina-Italia) de Investigaciones en Criobiología Clínica y Aplicada (CAIC), Universidad Nacional de Rosario, Rosario, 2000, Argentina.
| | - Eduardo A Ceccarelli
- Instituto de Biología Molecular y Celular de Rosario (IBR), Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Facultad de Ciencias Bioquímicas y Farmacéuticas, Universidad Nacional de Rosario, Rosario, 2000, Argentina.
| | - Edgardo E Guibert
- Centro Binacional (Argentina-Italia) de Investigaciones en Criobiología Clínica y Aplicada (CAIC), Universidad Nacional de Rosario, Rosario, 2000, Argentina.
| | - Germán L Rosano
- Instituto de Biología Molecular y Celular de Rosario (IBR), Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Facultad de Ciencias Bioquímicas y Farmacéuticas, Universidad Nacional de Rosario, Rosario, 2000, Argentina.
| |
Collapse
|
22
|
Tabka D, Bejaoui M, Javellaud J, Achard JM, Ben Abdennebi H. Angiotensin IV improves subnormothermic machine perfusion preservation of rat liver graft. Biomed Pharmacother 2018; 104:841-847. [PMID: 29609847 DOI: 10.1016/j.biopha.2018.02.080] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2017] [Revised: 01/31/2018] [Accepted: 02/19/2018] [Indexed: 12/25/2022] Open
Abstract
This study aims to determine whether Angiotensin IV (Ang IV) addition to Celsior preservation solution could improve hepatic endothelium function and provide better liver protection during subnormothermic machine preservation (SMP). Two experimental models were used: In the first part of the study, rings isolated from rat hepatic artery were preserved in Celsior solution (6 h, 20 °C) with and without Ang IV (10-9 M), then, endothelium-dependent relaxation (EDR) and the concentration of acetylcholine inducing half-maximal relaxation of pre-contracted rings (EC50) were measured. Also, in order to investigate the implication of nitric oxide (NO) on EDR, the rings of hepatic artery were incubated with L-NG-nitroarginine metyl ester (L-NAME). In the second part of the study, rat livers were subjected to SMP with oxygenated Celsior solution (6 h, 20 °C), supplemented or not with Ang IV (10-9 M) and then perfused (2 h, 37 °C) with Krebs Henseleit solution. We found that Ang IV supplementation to Celsior solution decreased EC50 value and improved EDR of hepatic artery rings, 6h after sub-normothermic preservation. Interestingly, Ang IV amplified the vessel relaxation in a NO-dependent manner. Moreover, liver SMP with Ang IV reduced oxidative stress and cell injury and improved organ function. Ang IV activated pAkt, increased eNOS protein level and decreased apoptosis in the preserved liver grafts. In conclusion, we showed that the use of Ang IV in Celsior solution for sub-normothermic graft preservation insured a better NO-dependent relaxation and improved liver functional recovery.
Collapse
Affiliation(s)
- Donia Tabka
- Unité de Biologie et Anthropologie Moléculaire Appliquées au Développement et à la Santé (UR12ES11), Faculté de Pharmacie, Université de Monastir, Monastir, Tunisia
| | - Mohamed Bejaoui
- Unité de Biologie et Anthropologie Moléculaire Appliquées au Développement et à la Santé (UR12ES11), Faculté de Pharmacie, Université de Monastir, Monastir, Tunisia
| | - James Javellaud
- INSERM, Unité Mixte de Recherche S-850, 8000 Limoges, France
| | | | - Hassen Ben Abdennebi
- Unité de Biologie et Anthropologie Moléculaire Appliquées au Développement et à la Santé (UR12ES11), Faculté de Pharmacie, Université de Monastir, Monastir, Tunisia
| |
Collapse
|
23
|
Avruch JH, Bruinsma BG, Weeder PD, Sridharan GV, Porte RJ, Yeh H, Markmann JF, Uygun K. A novel model for ex situ reperfusion of the human liver following subnormothermic machine perfusion. TECHNOLOGY 2017; 5:196-200. [PMID: 31106253 PMCID: PMC6524532 DOI: 10.1142/s2339547817500108] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Machine perfusion-based organ preservation techniques are prudently transitioning into clinical practice. Although experimental data is compelling, the outcomes in the highly variable clinical donation-transplantation setting are unpredictable. Here, we offer an intermediate tool for pre-clinical assessment of human donor livers. We present a model for ex situ reperfusion of discarded human livers and report on its application in three human livers that have undergone subnormothermic (21°C) machine perfusion as an experimental preservation method. During reperfusion, the livers macroscopically reperfused in the first 15 minutes, and remained visually well-perfused for 3 hours of ex situ reperfusion. Bile production and oxygen consumption were observed throughout ex situ reperfusion. ATP levels increased 4.25-fold during SNMP. Between the end of SNMP and the end of reperfusion ATP levels dropped 45%. ALT levels in blood increased rapidly in the first 30 minutes and ALT release continued to taper off towards the end of perfusion. Release of CRP, TNF-α, IL-1β, and IL-12, IFN-γ was sustained during reperfusion. These findings support the use of this model for the evaluation of novel human liver preservation techniques.
Collapse
Affiliation(s)
- James H Avruch
- Center for Engineering in Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
- Transplant Center, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Bote G Bruinsma
- Center for Engineering in Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
- Transplant Center, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Pepijn D Weeder
- Center for Engineering in Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
- Section of Hepatobiliary Surgery and Liver Transplantation, Department of Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Gautham V Sridharan
- Center for Engineering in Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Robert J Porte
- Section of Hepatobiliary Surgery and Liver Transplantation, Department of Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Heidi Yeh
- Transplant Center, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - James F Markmann
- Transplant Center, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Korkut Uygun
- Center for Engineering in Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
24
|
Abstract
PURPOSE OF REVIEW Herein, we review the field of subzero organ preservation with a focus on recent developments in hepatic supercooling. RECENT FINDINGS Organ preservation is making a rapid shift from the decade old standard of storage on ice toward techniques that improve organ availability as well as preservation time. Long-term organ preservation would have tremendous benefits to the organ transplantation field, including better organ allocation, donor-recipient matching, as well as reduced preservation injury, and subsequent improvement of donor organ use. The formation of ice has proven an important limiting factor and novel techniques attempt to control or prevent freezing using cryoprotective agents, and highly controlled cooling regimens. Various techniques have been employed over the previous decades, including true organ freezing, vitrification, and subzero nonfreezing or supercooling. For most techniques, successful transplantation following long-term subzero preservation has remained elusive. Supercooling, however, recently delivered the first promising results, yielding survival after up to 4 days of supercooled preservation at -6°C. SUMMARY As the field of organ preservation undergoes significant development, the field of subzero preservation also receives renewed interest. Although many obstacles remain to be overcome to make subzero preservation feasible, novel techniques are beginning to show their potential in achieving long-term preservation.
Collapse
|
25
|
Ghinolfi D, Rreka E, Pezzati D, Filipponi F, De Simone P. Perfusion machines and hepatocellular carcinoma: a good match between a marginal organ and an advanced disease? Transl Gastroenterol Hepatol 2017; 2:87. [PMID: 29264425 DOI: 10.21037/tgh.2017.10.01] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/14/2017] [Accepted: 09/27/2017] [Indexed: 12/12/2022] Open
Abstract
Hepatocellular carcinoma (HCC) accounts for 90% of primary liver cancers, is the second leading cause of cancer-related deaths and the leading cause of death in patients with cirrhosis. Liver transplantation (LT) represents the ideal treatment for selected patients as it removes both the tumor and the underlying cirrhotic liver with 5-year survival rates higher than 70%. Unfortunately, due to tumor characteristics, patient co-morbidities or shortage of organs available for transplant, only 20% of patients can undergo curative treatment. Ex situ machine perfusion (MP) is a technology recently introduced that might potentially improve organ preservation, allow graft assessment and increase the pool of available organs. The purpose of this review is to provide an update on the current role of ex situ liver MP in liver transplantation for HCC patients.
Collapse
Affiliation(s)
- Davide Ghinolfi
- Division of Hepatobiliary Surgery and Liver Transplantation, University of Pisa Medical School Hospital, Pisa, Tuscany, Italy
| | - Erion Rreka
- Division of Hepatobiliary Surgery and Liver Transplantation, University of Pisa Medical School Hospital, Pisa, Tuscany, Italy
| | - Daniele Pezzati
- Division of Hepatobiliary Surgery and Liver Transplantation, University of Pisa Medical School Hospital, Pisa, Tuscany, Italy
| | - Franco Filipponi
- Division of Hepatobiliary Surgery and Liver Transplantation, University of Pisa Medical School Hospital, Pisa, Tuscany, Italy
| | - Paolo De Simone
- Division of Hepatobiliary Surgery and Liver Transplantation, University of Pisa Medical School Hospital, Pisa, Tuscany, Italy
| |
Collapse
|
26
|
Bochimoto H, Matsuno N, Ishihara Y, Shonaka T, Koga D, Hira Y, Nishikawa Y, Furukawa H, Watanabe T. The ultrastructural characteristics of porcine hepatocytes donated after cardiac death and preserved with warm machine perfusion preservation. PLoS One 2017; 12:e0186352. [PMID: 29023512 PMCID: PMC5638504 DOI: 10.1371/journal.pone.0186352] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2016] [Accepted: 10/01/2017] [Indexed: 12/15/2022] Open
Abstract
The effects of warm machine perfusion preservation of liver grafts donated after cardiac death on the intracellular three-dimensional ultrastructure of the organelles in hepatocytes remain unclear. Here we analyzed comparatively the ultrastructure of the endomembrane systems in porcine hepatocytes under warm ischemia and successive hypothermic and midthermic machine perfusion preservation, a type of the warm machine perfusion. Porcine liver grafts which had a warm ischemia time of 60 minutes were perfused for 4 hours with modified University of Wisconsin gluconate solution. Group A grafts were preserved with hypothermic machine perfusion preservation at 8°C constantly for 4 hours. Group B grafts were preserved with rewarming up to 22°C by warm machine perfusion preservation for 4 hours. An analysis of hepatocytes after 60 minutes of warm ischemia by scanning electron microscope revealed the appearance of abnormal vacuoles and invagination of mitochondria. In the hepatocytes preserved by subsequent hypothermic machine perfusion preservation, strongly swollen mitochondria were observed. In contrast, the warm machine perfusion preservation could preserve the functional appearance of mitochondria in hepatocytes. Furthermore, abundant vacuoles and membranous structures sequestrating cellular organelles like autophagic vacuoles were frequently observed in hepatocytes after warm machine perfusion preservation. In conclusion, the ultrastructure of the endomembrane systems in the hepatocytes of liver grafts changed in accordance with the temperature conditions of machine perfusion preservation. In addition, temperature condition of the machine perfusion preservation may also affect the condition of the hepatic graft attributed to autophagy systems, and consequently alleviate the damage of the hepatocytes.
Collapse
Affiliation(s)
- Hiroki Bochimoto
- Health Care Administration Center, Obihiro University of Agriculture and Veterinary Medicine, Obihiro, Hokkaido, Japan
| | - Naoto Matsuno
- Department of Surgery, Asahikawa Medical University, Asahikawa, Hokkaido, Japan
- * E-mail:
| | - Yo Ishihara
- Department of Microscopic Anatomy and Cell Biology, Asahikawa Medical University, Asahikawa, Hokkaido, Japan
| | - Tatsuya Shonaka
- Department of Surgery, Asahikawa Medical University, Asahikawa, Hokkaido, Japan
| | - Daisuke Koga
- Department of Microscopic Anatomy and Cell Biology, Asahikawa Medical University, Asahikawa, Hokkaido, Japan
| | - Yoshiki Hira
- Area of Functional Anatomy, Department of Nursing, Asahikawa Medical University, Asahikawa, Hokkaido, Japan
| | - Yuji Nishikawa
- Department of Pathology, Asahikawa Medical University, Asahikawa, Hokkaido, Japan
| | - Hiroyuki Furukawa
- Department of Surgery, Asahikawa Medical University, Asahikawa, Hokkaido, Japan
| | - Tsuyoshi Watanabe
- Department of Microscopic Anatomy and Cell Biology, Asahikawa Medical University, Asahikawa, Hokkaido, Japan
| |
Collapse
|
27
|
|
28
|
Bruinsma BG, Avruch JH, Sridharan GV, Weeder PD, Jacobs ML, Crisalli K, Amundsen B, Porte RJ, Markmann JF, Uygun K, Yeh H. Peritransplant Energy Changes and Their Correlation to Outcome After Human Liver Transplantation. Transplantation 2017; 101:1637-1644. [PMID: 28230641 PMCID: PMC5481470 DOI: 10.1097/tp.0000000000001699] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
BACKGROUND The ongoing shortage of donor livers for transplantation and the increased use of marginal livers necessitate the development of accurate pretransplant tests of viability. Considering the importance energy status during transplantation, we aimed to correlate peritransplant energy cofactors to posttransplant outcome and subsequently model this in an ex vivo setting. METHODS Sequential biopsies were taken from 19 donor livers postpreservation, as well as 30 minutes after portal venous reperfusion and hepatic arterial reperfusion and analyzed by liquid chromatography-mass spectrometry for energetic cofactors (adenosine triphosphate [ATP]/adenosine diphosphate [ADP]/adenosine monophosphate [AMP], nicotinamide adenine dinucleotide /NAD, nicotinamide adenine dinucleotide phosphate / nicotinamide adenine dinucleotide phosphate , flavin adenine dinucleotide , glutathione disulfide/glutathione). Energy status was correlated to posttransplant outcome. In addition, 4 discarded human donation after circulatory death livers were subjected to ex vivo reperfusion, modeling reperfusion injury and were similarly analyzed for energetic cofactors. RESULTS A rapid shift toward higher energy adenine nucleotides was observed following clinical reperfusion, with a 2.45-, 3.17- and 2.12-fold increase in ATP:ADP, ATP:AMP and energy charge after portal venous reperfusion, respectively. Seven of the 19 grafts developed early allograft dysfunction. Correlation with peritransplant cofactors revealed a significant difference in EC between early allograft dysfunction and normal functioning grafts (0.09 vs 0.31, P < 0.05). In the simulated reperfusion model, a similar trend in adenine nucleotide changes was observed. CONCLUSIONS A preserved energy status appears critical in the peritransplant period. Levels of adenine nucleotides change rapidly after reperfusion and ratios of ATP/ADP/AMP after reperfusion are significantly correlated to graft function. Using these markers as a viability test in combination with ex vivo reperfusion may provide a useful predictor of outcome that incorporates donor, preservation, and reperfusion factors.
Collapse
Affiliation(s)
- Bote G. Bruinsma
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
- Transplant Center, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - James H. Avruch
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
- Transplant Center, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Gautham V. Sridharan
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Pepijn D. Weeder
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
- Transplant Center, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
- Section of Hepatobiliary Surgery and Liver Transplantation, Department of Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Marie Louise Jacobs
- Transplant Center, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Kerry Crisalli
- Transplant Center, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Beth Amundsen
- Transplant Center, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Robert J. Porte
- Section of Hepatobiliary Surgery and Liver Transplantation, Department of Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - James F. Markmann
- Transplant Center, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Korkut Uygun
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Heidi Yeh
- Transplant Center, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
29
|
Abstract
The demand of donor livers for transplantation exceeds the supply. In an attempt to maximize the number of potentially usable donor livers, several centers are exploring the role of machine perfusion. This review provides an update on machine perfusion strategies and basic concepts, based on current clinical issues, and discuss challenges, including currently used biomarkers for assessing the quality and viability of perfused organs. The potential benefits of machine perfusion on immunogenicity and the consequences on post-operative immunosuppression management are discussed.
Collapse
|
30
|
Abstract
BACKGROUND The high demand for livers for transplantation has led to organs of limited quality being accepted to expand the donor pool. This is associated with inferior outcomes due to more pronounced preservation injury. Accordingly, recent research has aimed to develop preservation modalities for improved preservation as well as strategies for liver viability assessment and liver reconditioning. METHODS The PubMed database was searched using the terms 'perfusion', 'liver', 'preservation', and 'reconditioning' in various combinations, and the according literature was reviewed. RESULTS Several perfusion techniques have been developed in recent years with the potential for liver reconditioning. Preclinical and first emerging clinical data suggest feasibility, safety, and superiority over the current gold standard of cold storage. CONCLUSION This review outlines current advances in the field of liver preservation with an emphasis on liver reconditioning methods.
Collapse
Affiliation(s)
- Dieter P Hoyer
- General, Visceral and Transplantation Surgery, University Hospital Essen, Essen, Germany
| | - Thomas Minor
- General, Visceral and Transplantation Surgery, University Hospital Essen, Essen, Germany
| |
Collapse
|
31
|
Karangwa SA, Dutkowski P, Fontes P, Friend PJ, Guarrera JV, Markmann JF, Mergental H, Minor T, Quintini C, Selzner M, Uygun K, Watson CJ, Porte RJ. Machine Perfusion of Donor Livers for Transplantation: A Proposal for Standardized Nomenclature and Reporting Guidelines. Am J Transplant 2016; 16:2932-2942. [PMID: 27129409 PMCID: PMC5132023 DOI: 10.1111/ajt.13843] [Citation(s) in RCA: 97] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2016] [Revised: 03/28/2016] [Accepted: 04/19/2016] [Indexed: 02/06/2023]
Abstract
With increasing demand for donor organs for transplantation, machine perfusion (MP) promises to be a beneficial alternative preservation method for donor livers, particularly those considered to be of suboptimal quality, also known as extended criteria donor livers. Over the last decade, numerous studies researching MP of donor livers have been published and incredible advances have been made in both experimental and clinical research in this area. With numerous research groups working on MP, various techniques are being explored, often applying different nomenclature. The objective of this review is to catalog the differences observed in the nomenclature used in the current literature to denote various MP techniques and the manner in which methodology is reported. From this analysis, we propose a standardization of nomenclature on liver MP to maximize consistency and to enable reliable comparison and meta-analyses of studies. In addition, we propose a standardized set of guidelines for reporting the methodology of future studies on liver MP that will facilitate comparison as well as clinical implementation of liver MP procedures.
Collapse
Affiliation(s)
- S. A. Karangwa
- Section of Hepatobiliary Surgery and Liver TransplantationDepartment of SurgeryUniversity of GroningenUniversity Medical Center GroningenGroningenthe Netherlands
- Surgical Research LaboratoryUniversity of GroningenUniversity Medical Center GroningenGroningenthe Netherlands
| | - P. Dutkowski
- Department of Surgery & TransplantationUniversity Hospital ZurichZurichSwitzerland
| | - P. Fontes
- Thomas E. Starzl Transplantation Institute Department of SurgeryUniversity of Pittsburgh Medical CenterPittsburghPA
- McGowan Institute of Regenerative MedicineUniversity of PittsburghPittsburghPA
| | - P. J. Friend
- Nuffield Department of SurgeryOxford Transplant CentreUniversity of OxfordChurchill HospitalOxfordUK
| | - J. V. Guarrera
- Department of SurgeryCenter for Liver Disease and TransplantationColumbia University Medical CenterNew YorkNY
| | | | - H. Mergental
- Liver UnitUniversity Hospital BirminghamBirminghamUK
| | - T. Minor
- Department of Surgical ResearchClinic for General Visceral and Transplantation SurgeryUniversity Hospital EssenEssenGermany
| | - C. Quintini
- Department of SurgeryTransplant CenterDigestive Disease InstituteCleveland Clinic FoundationClevelandOH
| | - M. Selzner
- Department of SurgeryMulti Organ Transplant ProgramToronto General HospitalTorontoONCanada
| | - K. Uygun
- Department of SurgeryCenter for Engineering in MedicineMassachusetts General HospitalHarvard Medical SchoolBostonMA
| | - C. J. Watson
- University of Cambridge Department of Surgery and the NIHR Blood and Transplant Research Unit in Organ Donation and Transplantation University of CambridgeAddenbrooke's HospitalCambridgeUK
| | - R. J. Porte
- Section of Hepatobiliary Surgery and Liver TransplantationDepartment of SurgeryUniversity of GroningenUniversity Medical Center GroningenGroningenthe Netherlands
| |
Collapse
|
32
|
Jia JJ, Zhang J, Li JH, Chen XD, Jiang L, Zhou YF, He N, Xie HY, Zhou L, Zheng SS. Influence of perfusate on liver viability during hypothermic machine perfusion. World J Gastroenterol 2015; 21:8848-8857. [PMID: 26269674 PMCID: PMC4528027 DOI: 10.3748/wjg.v21.i29.8848] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/11/2015] [Revised: 04/12/2015] [Accepted: 06/10/2015] [Indexed: 02/07/2023] Open
Abstract
AIM: To optimize the perfusates used for hypothermic machine perfusion (HMP).
METHODS: Sprague-Dawley rats were assigned randomly to three groups (n = 12 per group) that received either saline, University of Wisconsin cold-storage solution (UW) or histidine-tryptophan-ketoglutarate solution (HTK) as the perfusate. Each group was divided into two subgroups: static cold storage (SCS) and HMP (n = 6 per subgroup). The liver graft was retrieved according to the method described by Kamada. For the SCS group, the graft was directly placed into cold perfusate (0-4 °C) for 6 h after liver isolation while the portal vein of the graft was connected to the perfusion machine for the HMP group. Then the perfusates were collected at different time points for analysis of aspartate aminotransferase (AST), alanine transaminase (ALT) and lactate dehydrogenase (LDH) levels. Liver tissues were obtained for evaluation of histology, dry/wet weight (D/W) ratio, and malondialdehyde (MDA) and adenosine-triphosphate (ATP) levels. The portal vein pressure and velocity were monitored in real time in all HMP subgroups.
RESULTS: Comparison of HMP and SCS: Regardless of the perfusate, HMP improved the architecture of donor graft in reducing the congestion around sinusoids and central vein and maintaining sinusoid lining in morphology; HMP improved liver function in terms of ALT, AST and LDH, especially during the 3-6 h period (SCS vs HMP using saline: ALT3, 225.00 ± 105.62 vs 49.50 ± 18.50, P = 0.047; LDH3, 1362.17 ± 563.30 vs 325.75 ± 147.43, P = 0.041; UW: LDH6, 2880.14 ± 948.46 vs 2135.00 ± 174.27, P = 0.049; HTK, AST6, 307.50 ± 52.95 vs 185.20 ± 20.46, P = 0.041); HMP decreased MDA level (saline, 2.79 ± 0.30 vs 1.09 ± 0.09, P = 0.008; UW, 3.01 ± 0.77 vs 1.23 ± 0.68, P = 0.005; HTK, 3.30 ± 0.52 vs 1.56 ± 0.22, P = 0.006). Comparison among HMP subgroups: HTK showed less portal vein resistance than UW and saline (vs saline, 3.41 ± 0.49 vs 5.00 ± 0.38, P < 0.001; vs UW, 3.41 ± 0.49 vs 4.52 ± 0.63, P = 0.007); UW reduced edema most efficiently (vs saline, 0.68 ± 0.02 vs 0.79 ± 0.05, P = 0.013), while HTK maintained ATP levels best (vs saline, 622.60 ± 29.11 vs 327.43 ± 44.66, P < 0.001; vs UW, 622.60 ± 29.11 vs 301.80 ± 37.68, P < 0.001).
CONCLUSION: HMP is superior to SCS in maintaining both architecture and function of liver grafts. Further, HTK was found to be the optimal perfusate for HMP.
Collapse
|
33
|
Bruinsma BG, Wu W, Ozer S, Farmer A, Markmann JF, Yeh H, Uygun K. Warm ischemic injury is reflected in the release of injury markers during cold preservation of the human liver. PLoS One 2015; 10:e0123421. [PMID: 25822248 PMCID: PMC4378972 DOI: 10.1371/journal.pone.0123421] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2014] [Accepted: 02/23/2015] [Indexed: 12/18/2022] Open
Abstract
BACKGROUND Liver transplantation plays a pivotal role in the treatment of patients with end-stage liver disease. Despite excellent outcomes, the field is strained by a severe shortage of viable liver grafts. To meet high demands, attempts are made to increase the use of suboptimal livers by both pretransplant recovery and assessment of donor livers. Here we aim to assess hepatic injury in the measurement of routine markers in the post-ischemic flush effluent of discarded human liver with a wide warm ischemic range. METHODS Six human livers discarded for transplantation with variable warm and cold ischemia times were flushed at the end of preservation. The liver grafts were flushed with NaCl or Lactated Ringer's, 2 L through the portal vein and 1 L through the hepatic artery. The vena caval effluent was sampled and analyzed for biochemical markers of injury; lactate dehydrogenase (LDH), alanine transaminase (ALT), and alkaline phosphatase (ALP). Liver tissue biopsies were analyzed for ATP content and histologically (H&E) examined. RESULTS The duration of warm ischemia in the six livers correlated significantly to the concentration of LDH, ALT, and ALP in the effluent from the portal vein flush. No correlation was found with cold ischemia time. Tissue ATP content at the end of preservation correlated very strongly with the concentration of ALP in the arterial effluent (P<0.0007, R2 = 0.96). CONCLUSION Biochemical injury markers released during the cold preservation period were reflective of the duration of warm ischemic injury sustained prior to release of the markers, as well as the hepatic energy status. As such, assessment of the flush effluent at the end of cold preservation may be a useful tool in evaluating suboptimal livers prior to transplantation, particularly in situations with undeterminable ischemic durations.
Collapse
Affiliation(s)
- Bote G. Bruinsma
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital/ Harvard Medical School, Boston, Massachusetts, United States
- Department of Surgery (Surgical Laboratory), Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands
| | - Wilson Wu
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital/ Harvard Medical School, Boston, Massachusetts, United States
| | - Sinan Ozer
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital/ Harvard Medical School, Boston, Massachusetts, United States
| | - Adam Farmer
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital/ Harvard Medical School, Boston, Massachusetts, United States
| | - James F. Markmann
- Transplant Center, Massachusetts General Hospital/ Harvard Medical School, Boston, Massachusetts, United States
| | - Heidi Yeh
- Transplant Center, Massachusetts General Hospital/ Harvard Medical School, Boston, Massachusetts, United States
| | - Korkut Uygun
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital/ Harvard Medical School, Boston, Massachusetts, United States
- * E-mail:
| |
Collapse
|
34
|
Abstract
The current standard for liver preservation involves cooling of the organ on ice (0-4 °C). Although it is successful for shorter durations, this method of preservation does not allow long-term storage of the liver. The gradual loss of hepatic viability during preservation puts pressure on organ sharing and allocation, may limit the use of suboptimal grafts and necessitates rushed transplantation to achieve desirable post-transplantation outcomes. In an attempt to improve and prolong liver viability during storage, alternative preservation methods are under investigation. For instance, ex vivo machine perfusion systems aim to sustain and even improve viability by supporting hepatic function at warm temperatures, rather than simply slowing down deterioration by cooling. Here we describe a novel subzero preservation technique that combines ex vivo machine perfusion with cryoprotectants to facilitate long-term supercooled preservation. The technique improves the preservation of rat livers to prolong storage times as much as threefold, which is validated by successful long-term recipient survival after orthotopic transplantation. This protocol describes how to load rat livers with cryoprotectants to prevent both intracellular and extracellular ice formation and to protect against hypothermic injury. Cryoprotectants are loaded ex vivo using subnormothermic machine perfusion (SNMP), after which livers can be cooled to -6 °C without freezing and kept viable for up to 96 h. Cooling to a supercooled state is controlled, followed by 3 h of SNMP recovery and orthotopic liver transplantation.
Collapse
|
35
|
Dutkowski P, Linecker M, DeOliveira ML, Müllhaupt B, Clavien PA. Challenges to liver transplantation and strategies to improve outcomes. Gastroenterology 2015; 148:307-23. [PMID: 25224524 DOI: 10.1053/j.gastro.2014.08.045] [Citation(s) in RCA: 191] [Impact Index Per Article: 21.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/04/2014] [Revised: 08/29/2014] [Accepted: 08/29/2014] [Indexed: 02/07/2023]
Abstract
Liver transplantation (LT) is a highly successful treatment for many patients with nonmalignant and malignant liver diseases. However, there is a worldwide shortage of available organs; many patients deteriorate or die while on waiting lists. We review the important clinical challenges to LT and the best use of the scarce organs. We focus on changes in indications for LT and discuss scoring systems to best match donors with recipients and optimize outcomes, particularly for the sickest patients. We also cover controversial guidelines for the use of LT in patients with hepatocellular carcinoma and cholangiocarcinoma. Strategies to increase the number of functional donor organs involve techniques to perfuse the organs before implantation. Partial LT (living donor and split liver transplantation) techniques might help to overcome organ shortages, and we discuss small-for-size syndrome. Many new developments could increase the success of this procedure, which is already one of the major achievements in medicine during the second part of the 20th century.
Collapse
Affiliation(s)
- Philipp Dutkowski
- Swiss HPB and Transplantation Center, Departments of Surgery and Medicine, University Hospital Zurich, Zurich, Switzerland
| | - Michael Linecker
- Swiss HPB and Transplantation Center, Departments of Surgery and Medicine, University Hospital Zurich, Zurich, Switzerland
| | - Michelle L DeOliveira
- Swiss HPB and Transplantation Center, Departments of Surgery and Medicine, University Hospital Zurich, Zurich, Switzerland
| | - Beat Müllhaupt
- Swiss HPB and Transplantation Center, Departments of Surgery and Medicine, University Hospital Zurich, Zurich, Switzerland
| | - Pierre-Alain Clavien
- Swiss HPB and Transplantation Center, Departments of Surgery and Medicine, University Hospital Zurich, Zurich, Switzerland.
| |
Collapse
|
36
|
|
37
|
van Golen RF, Reiniers MJ, van Gulik TM, Heger M. Organ cooling in liver transplantation and resection: how low should we go? Hepatology 2015; 61:395-9. [PMID: 25363089 DOI: 10.1002/hep.27590] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Affiliation(s)
- Rowan F van Golen
- Department of Experimental Surgery, Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands
| | | | | | | |
Collapse
|
38
|
Reply to: "pre-retrieval reperfusion decreases cancer recurrence after rat ischemic liver graft transplantation". J Hepatol 2014; 61:962-3. [PMID: 24950481 DOI: 10.1016/j.jhep.2014.06.011] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2014] [Accepted: 06/08/2014] [Indexed: 12/04/2022]
|
39
|
Supercooling enables long-term transplantation survival following 4 days of liver preservation. Nat Med 2014; 20:790-3. [PMID: 24973919 PMCID: PMC4141719 DOI: 10.1038/nm.3588] [Citation(s) in RCA: 138] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2012] [Accepted: 02/27/2014] [Indexed: 12/28/2022]
Abstract
The realization of long–term human organ preservation will have groundbreaking effects on the current practice of transplantation. Herein we present a novel technique based on sub–zero non–freezing tissue preservation and extracorporeal machine perfusion that allows transplantation of rat livers preserved for up to 4 days, thereby tripling the viable preservation duration.
Collapse
|
40
|
Dutkowski P, Clavien PA. Solutions to shortage of liver grafts for transplantation. Br J Surg 2014; 101:739-41. [PMID: 24817650 DOI: 10.1002/bjs.9540] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Increasing the donor supply
Collapse
Affiliation(s)
- P Dutkowski
- Swiss Hepatopancreatobiliary and Transplantation Centre, Department of Surgery, University Hospital Zurich, Raemistrasse 100, CH-8091, Zurich, Switzerland
| | | |
Collapse
|
41
|
Bruinsma B, Yeh H, Özer S, Martins P, Farmer A, Wu W, Saeidi N, op den Dries S, Berendsen T, Smith R, Markmann J, Porte R, Yarmush M, Uygun K, Izamis M. Subnormothermic machine perfusion for ex vivo preservation and recovery of the human liver for transplantation. Am J Transplant 2014; 14:1400-9. [PMID: 24758155 PMCID: PMC4470578 DOI: 10.1111/ajt.12727] [Citation(s) in RCA: 148] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2013] [Revised: 02/25/2014] [Accepted: 02/26/2014] [Indexed: 01/25/2023]
Abstract
To reduce widespread shortages, attempts are made to use more marginal livers for transplantation. Many of these grafts are discarded for fear of inferior survival rates or biliary complications. Recent advances in organ preservation have shown that ex vivo subnormothermic machine perfusion has the potential to improve preservation and recover marginal livers pretransplantation. To determine the feasibility in human livers, we assessed the effect of 3 h of oxygenated subnormothermic machine perfusion (21°C) on seven livers discarded for transplantation. Biochemical and microscopic assessment revealed minimal injury sustained during perfusion. Improved oxygen uptake (1.30 [1.11-1.94] to 6.74 [4.15-8.16] mL O2 /min kg liver), lactate levels (4.04 [3.70-5.99] to 2.29 [1.20-3.43] mmol/L) and adenosine triphosphate content (45.0 [70.6-87.5] pmol/mg preperfusion to 167.5 [151.5-237.2] pmol/mg after perfusion) were observed. Liver function, reflected by urea, albumin and bile production, was seen during perfusion. Bile production increased and the composition of bile (bile salts/phospholipid ratio, pH and bicarbonate concentration) became more favorable. In conclusion, ex vivo subnormothermic machine perfusion effectively maintains liver function with minimal injury and sustains or improves various hepatobiliary parameters postischemia.
Collapse
Affiliation(s)
- B.G. Bruinsma
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Boston, MA, USA,Department of Surgery (Surgical Laboratory), Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - H. Yeh
- Transplant Center, Massachusetts General Hospital, Boston, MA, USA
| | - S Özer
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Boston, MA, USA
| | - P.N. Martins
- Organ Transplant Surgery, UMass Memorial Medical Center, Boston, MA, USA
| | - A. Farmer
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Boston, MA, USA
| | - W. Wu
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Boston, MA, USA
| | - N. Saeidi
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Boston, MA, USA
| | - S. op den Dries
- Section of Hepatobiliary Surgery and Liver Transplantation, Department of Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - T.A. Berendsen
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Boston, MA, USA
| | - R.N. Smith
- Department of Pathology, Massachusetts General Hospital, Boston, MA, USA
| | - J.F. Markmann
- Transplant Center, Massachusetts General Hospital, Boston, MA, USA
| | - R. Porte
- Section of Hepatobiliary Surgery and Liver Transplantation, Department of Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - M.L. Yarmush
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Boston, MA, USA,Department of Biomedical Engineering, Rutgers University, Piscataway, NJ, USA
| | - K. Uygun
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Boston, MA, USA,Corresponding authors Korkut Uygun, PhD , Maria-Louisa Izamis, PhD
| | - M.L. Izamis
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Boston, MA, USA,Corresponding authors Korkut Uygun, PhD , Maria-Louisa Izamis, PhD
| |
Collapse
|
42
|
Bruinsma BG, Yarmush ML, Uygun K. Organomatics and organometrics: Novel platforms for long-term whole-organ culture. TECHNOLOGY 2014; 2:13. [PMID: 25035864 PMCID: PMC4097862 DOI: 10.1142/s2339547814300029] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Organ culture systems are instrumental as experimental whole-organ models of physiology and disease, as well as preservation modalities facilitating organ replacement therapies such as transplantation. Nevertheless, a coordinated system of machine perfusion components and integrated regulatory control has yet to be fully developed to achieve long-term maintenance of organ function ex vivo. Here we outline current strategies for organ culture, or organomatics, and how these systems can be regulated by means of computational algorithms, or organometrics, to achieve the organ culture platforms anticipated in modern-day biomedicine.
Collapse
|