Rizzi S, Ragazzini S, Pesce M. Engineering Efforts to Refine Compatibility and Duration of Aortic Valve Replacements: An Overview of Previous Expectations and New Promises. Front Cardiovasc Med 2022; 9:863136. [PMID: 35509271 PMCID: PMC9058060 DOI: 10.3389/fcvm.2022.863136] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Accepted: 03/28/2022] [Indexed: 01/18/2023] Open
Abstract
The absence of pharmacological treatments to reduce or retard the progression of cardiac valve diseases makes replacement with artificial prostheses (mechanical or bio-prosthetic) essential. Given the increasing incidence of cardiac valve pathologies, there is always a more stringent need for valve replacements that offer enhanced performance and durability. Unfortunately, surgical valve replacement with mechanical or biological substitutes still leads to disadvantages over time. In fact, mechanical valves require a lifetime anticoagulation therapy that leads to a rise in thromboembolic complications, while biological valves are still manufactured with non-living tissue, consisting of aldehyde-treated xenograft material (e.g., bovine pericardium) whose integration into the host fails in the mid- to long-term due to unresolved issues regarding immune-compatibility. While various solutions to these shortcomings are currently under scrutiny, the possibility to implant fully biologically compatible valve replacements remains elusive, at least for large-scale deployment. In this regard, the failure in translation of most of the designed tissue engineered heart valves (TEHVs) to a viable clinical solution has played a major role. In this review, we present a comprehensive overview of the TEHVs developed until now, and critically analyze their strengths and limitations emerging from basic research and clinical trials. Starting from these aspects, we will also discuss strategies currently under investigation to produce valve replacements endowed with a true ability to self-repair, remodel and regenerate. We will discuss these new developments not only considering the scientific/technical framework inherent to the design of novel valve prostheses, but also economical and regulatory aspects, which may be crucial for the success of these novel designs.
Collapse
Affiliation(s)
- Stefano Rizzi
- Tissue Engineering Unit, Centro Cardiologico Monzino, Istituto di ricovero e cura a carattere scientifico (IRCCS), Milan, Italy
- Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Politecnico di Milano, Milan, Italy
- Stefano Rizzi
| | - Sara Ragazzini
- Tissue Engineering Unit, Centro Cardiologico Monzino, Istituto di ricovero e cura a carattere scientifico (IRCCS), Milan, Italy
| | - Maurizio Pesce
- Tissue Engineering Unit, Centro Cardiologico Monzino, Istituto di ricovero e cura a carattere scientifico (IRCCS), Milan, Italy
- *Correspondence: Maurizio Pesce
| |
Collapse
|
2
|
Design of an aortic polymeric valve with asymmetric leaflets and evaluation of its performance by finite element method. Comput Biol Med 2022; 145:105440. [PMID: 35339848 DOI: 10.1016/j.compbiomed.2022.105440] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2022] [Revised: 02/28/2022] [Accepted: 03/20/2022] [Indexed: 11/23/2022]
Abstract
BACKGROUND The geometry of leaflets plays a significant role in prosthetic valves' (PVs) performance. Typically, natural aortic valves have three unequal leaflets, which differ in size. The present study aims to design an asymmetric tri-leaflet polymeric valve with one large and two small leaflets based on commissure lengths and leaflet eccentricities. METHODS Eccentricity was related to commissure lengths based on the deformation of the free margins for the fully-opened state of leaflets. The polystyrene-block-polyethylene-polypropylene-block-polystyrene polymer characterized the material properties of the leaflets. The Finite Element Method (FEM) was used to evaluate performance parameters, including maximum geometric orifice area (GOA), average GOA, maximum von Mises stress, and leaflet's coaptation surface area (CSA). RESULTS Asymmetric valves with no eccentricity provided a low level of GOA because the asymmetric form of small leaflets caused them to close faster than the large leaflet, leading to a sudden drop in the GOA during systole. As the radial curve tends towards a straight line, an undesirable coaptation occurs, and peak stress increases despite higher GOAs. A new radial curve consisting of two straight lines connected by an arc that provided 25.64 mm2 coaptation surface area (CAS) and 117.54 mm2 average GOA, was proposed to improve coaptation and GOA. CONCLUSION The radial curve of leaflets affects the valve's performance more than other geometric parameters. The combination of straight lines and arcs for radial curves was selected as the reference model for asymmetric valves with one large and two small leaflets.
Collapse
|
3
|
Shao Z, Tao T, Xu H, Chen C, Lee I, Chung S, Dong Z, Li W, Ma L, Bai H, Chen Q. Recent progress in biomaterials for heart valve replacement: Structure, function, and biomimetic design. VIEW 2021. [DOI: 10.1002/viw.20200142] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Affiliation(s)
- Ziyu Shao
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine & Clinical Research Center for Oral Diseases of Zhejiang Province Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University Hangzhou 310006 China
- State Key Laboratory of Chemical Engineering College of Chemical and Biological Engineering Zhejiang University Hangzhou China
| | - Tingting Tao
- Department of Cardiovascular Surgery The First Affiliated Hospital Zhejiang University School of Medicine Hangzhou Zhejiang Province China
| | - Hongfei Xu
- Department of Cardiovascular Surgery The First Affiliated Hospital Zhejiang University School of Medicine Hangzhou Zhejiang Province China
| | - Cen Chen
- College of Life Sciences and Medicine Zhejiang Sci‐Tech University Hangzhou China
| | - In‐Seop Lee
- College of Life Sciences and Medicine Zhejiang Sci‐Tech University Hangzhou China
- Institute of Natural Sciences Yonsei University Seoul Republic of Korea
| | - Sungmin Chung
- Biomaterials R&D Center GENOSS Co., Ltd. Suwon‐si Republic of Korea
| | - Zhihui Dong
- State Key Laboratory of Chemical Engineering College of Chemical and Biological Engineering Zhejiang University Hangzhou China
| | - Weidong Li
- Department of Cardiovascular Surgery The First Affiliated Hospital Zhejiang University School of Medicine Hangzhou Zhejiang Province China
| | - Liang Ma
- Department of Cardiovascular Surgery The First Affiliated Hospital Zhejiang University School of Medicine Hangzhou Zhejiang Province China
| | - Hao Bai
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine & Clinical Research Center for Oral Diseases of Zhejiang Province Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University Hangzhou 310006 China
- State Key Laboratory of Chemical Engineering College of Chemical and Biological Engineering Zhejiang University Hangzhou China
| | - Qianming Chen
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine & Clinical Research Center for Oral Diseases of Zhejiang Province Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University Hangzhou 310006 China
| |
Collapse
|
4
|
Wang H, Song H, Yang Y, Cao Q, Hu Y, Chen J, Guo J, Wang Y, Jia D, Cao S, Zhou Q. Three-dimensional printing for cardiovascular diseases: from anatomical modeling to dynamic functionality. Biomed Eng Online 2020; 19:76. [PMID: 33028306 PMCID: PMC7542711 DOI: 10.1186/s12938-020-00822-y] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2020] [Accepted: 09/28/2020] [Indexed: 12/16/2022] Open
Abstract
Three-dimensional (3D) printing is widely used in medicine. Most research remains focused on forming rigid anatomical models, but moving from static models to dynamic functionality could greatly aid preoperative surgical planning. This work reviews literature on dynamic 3D heart models made of flexible materials for use with a mock circulatory system. Such models allow simulation of surgical procedures under mock physiological conditions, and are; therefore, potentially very useful to clinical practice. For example, anatomical models of mitral regurgitation could provide a better display of lesion area, while dynamic 3D models could further simulate in vitro hemodynamics. Dynamic 3D models could also be used in setting standards for certain parameters for function evaluation, such as flow reserve fraction in coronary heart disease. As a bridge between medical image and clinical aid, 3D printing is now gradually changing the traditional pattern of diagnosis and treatment.
Collapse
Affiliation(s)
- Hao Wang
- Department of Ultrasound Imaging, Renmin Hospital of Wuhan University, Wuhan, 430060, China
| | - Hongning Song
- Department of Ultrasound Imaging, Renmin Hospital of Wuhan University, Wuhan, 430060, China
| | - Yuanting Yang
- Department of Ultrasound Imaging, Renmin Hospital of Wuhan University, Wuhan, 430060, China
| | - Quan Cao
- Department of Ultrasound Imaging, Renmin Hospital of Wuhan University, Wuhan, 430060, China
| | - Yugang Hu
- Department of Ultrasound Imaging, Renmin Hospital of Wuhan University, Wuhan, 430060, China
| | - Jinling Chen
- Department of Ultrasound Imaging, Renmin Hospital of Wuhan University, Wuhan, 430060, China
| | - Juan Guo
- Department of Ultrasound Imaging, Renmin Hospital of Wuhan University, Wuhan, 430060, China
| | - Yijia Wang
- Department of Ultrasound Imaging, Renmin Hospital of Wuhan University, Wuhan, 430060, China
| | - Dan Jia
- Department of Ultrasound Imaging, Renmin Hospital of Wuhan University, Wuhan, 430060, China
| | - Sheng Cao
- Department of Ultrasound Imaging, Renmin Hospital of Wuhan University, Wuhan, 430060, China
| | - Qing Zhou
- Department of Ultrasound Imaging, Renmin Hospital of Wuhan University, Wuhan, 430060, China.
| |
Collapse
|
5
|
Luraghi G, De Gaetano F, Rodriguez Matas JF, Dubini G, Costantino ML, De Castilla H, Griffaton N, Vignale D, Palmisano A, Gentile G, Esposito A, Migliavacca F. A numerical investigation to evaluate the washout of blood compartments in a total artificial heart. Artif Organs 2020; 44:976-986. [DOI: 10.1111/aor.13717] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2019] [Revised: 02/28/2020] [Accepted: 04/23/2020] [Indexed: 12/31/2022]
Affiliation(s)
- Giulia Luraghi
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering “Giulio Natta” Politecnico di Milano Milan Italy
| | - Francesco De Gaetano
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering “Giulio Natta” Politecnico di Milano Milan Italy
| | - José Félix Rodriguez Matas
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering “Giulio Natta” Politecnico di Milano Milan Italy
| | - Gabriele Dubini
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering “Giulio Natta” Politecnico di Milano Milan Italy
| | - Maria Laura Costantino
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering “Giulio Natta” Politecnico di Milano Milan Italy
| | | | | | - Davide Vignale
- Experimental Imaging Center IRCCS Ospedale San Raffaele Milan Italy
- Università Vita‐Salute San Raffaele Milan Italy
| | - Anna Palmisano
- Experimental Imaging Center IRCCS Ospedale San Raffaele Milan Italy
- Università Vita‐Salute San Raffaele Milan Italy
| | - Giuseppe Gentile
- Experimental Imaging Center IRCCS Ospedale San Raffaele Milan Italy
| | - Antonio Esposito
- Experimental Imaging Center IRCCS Ospedale San Raffaele Milan Italy
- Università Vita‐Salute San Raffaele Milan Italy
| | - Francesco Migliavacca
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering “Giulio Natta” Politecnico di Milano Milan Italy
| |
Collapse
|
6
|
Rusu LC, Ardelean LC, Jitariu AA, Miu CA, Streian CG. An Insight into the Structural Diversity and Clinical Applicability of Polyurethanes in Biomedicine. Polymers (Basel) 2020; 12:E1197. [PMID: 32456335 PMCID: PMC7285236 DOI: 10.3390/polym12051197] [Citation(s) in RCA: 39] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Revised: 05/13/2020] [Accepted: 05/22/2020] [Indexed: 01/16/2023] Open
Abstract
Due to their mechanical properties, ranging from flexible to hard materials, polyurethanes (PUs) have been widely used in many industrial and biomedical applications. PUs' characteristics, along with their biocompatibility, make them successful biomaterials for short and medium-duration applications. The morphology of PUs includes two structural phases: hard and soft segments. Their high mechanical resistance featuresare determined by the hard segment, while the elastomeric behaviour is established by the soft segment. The most important biomedical applications of PUs include antibacterial surfaces and catheters, blood oxygenators, dialysis devices, stents, cardiac valves, vascular prostheses, bioadhesives/surgical dressings/pressure-sensitive adhesives, drug delivery systems, tissue engineering scaffolds and electrospinning, nerve generation, pacemaker lead insulation and coatings for breast implants. The diversity of polyurethane properties, due to the ease of bulk and surface modification, plays a vital role in their applications.
Collapse
Affiliation(s)
- Laura-Cristina Rusu
- Department of Oral Pathology, “Victor Babes” University of Medicine and Pharmacy Timisoara, 2 Eftimie Murgu sq, 300041 Timisoara, Romania;
| | - Lavinia Cosmina Ardelean
- Department of Technology of Materials and Devices in Dental Medicine, “Victor Babes” University of Medicine and Pharmacy Timisoara, 2 Eftimie Murgu sq, 300041 Timisoara, Romania
| | - Adriana-Andreea Jitariu
- Department of Microscopic Morphology/Histology and Angiogenesis Research Center Timisoara, “Victor Babes” University of Medicine and Pharmacy Timisoara, 2 Eftimie Murgu sq, 300041 Timisoara, Romania;
| | - Catalin Adrian Miu
- 3rd Department of Orthopaedics-Traumatology, “Victor Babes” University of Medicine and Pharmacy Timisoara, 2 Eftimie Murgu sq, 300041 Timisoara, Romania;
| | - Caius Glad Streian
- Department of Cardiac Surgery, “Victor Babes” University of Medicine and Pharmacy Timisoara, 2 Eftimie Murgu sq, 300041 Timisoara, Romania;
| |
Collapse
|
7
|
Stasiak JR, Serrani M, Biral E, Taylor JV, Zaman AG, Jones S, Ness T, De Gaetano F, Costantino ML, Bruno VD, Suleiman S, Ascione R, Moggridge GD. Design, development, testing at ISO standards and in vivo feasibility study of a novel polymeric heart valve prosthesis. Biomater Sci 2020; 8:4467-4480. [DOI: 10.1039/d0bm00412j] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A novel polymeric heart valve shows durability equivalent to 25 years in accelerated bench testing, in vitro hydrodynamics equivalent to existing bioprosthetic valves; and good performance in a small acute feasibility study in sheep.
Collapse
|
8
|
Li RL, Russ J, Paschalides C, Ferrari G, Waisman H, Kysar JW, Kalfa D. Mechanical considerations for polymeric heart valve development: Biomechanics, materials, design and manufacturing. Biomaterials 2019; 225:119493. [PMID: 31569017 PMCID: PMC6948849 DOI: 10.1016/j.biomaterials.2019.119493] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2019] [Revised: 08/21/2019] [Accepted: 09/11/2019] [Indexed: 01/12/2023]
Abstract
The native human heart valve leaflet contains a layered microstructure comprising a hierarchical arrangement of collagen, elastin, proteoglycans and various cell types. Here, we review the various experimental methods that have been employed to probe this intricate microstructure and which attempt to elucidate the mechanisms that govern the leaflet's mechanical properties. These methods include uniaxial, biaxial, and flexural tests, coupled with microstructural characterization techniques such as small angle X-ray scattering (SAXS), small angle light scattering (SALS), and polarized light microscopy. These experiments have revealed complex elastic and viscoelastic mechanisms that are highly directional and dependent upon loading conditions and biochemistry. Of all engineering materials, polymers and polymer-based composites are best able to mimic the tissue-level mechanical behavior of the native leaflet. This similarity to native tissue permits the fabrication of polymeric valves with physiological flow patterns, reducing the risk of thrombosis compared to mechanical valves and in some cases surpassing the in vivo durability of bioprosthetic valves. Earlier work on polymeric valves simply assumed the mechanical properties of the polymer material to be linear elastic, while more recent studies have considered the full hyperelastic stress-strain response. These material models have been incorporated into computational models for the optimization of valve geometry, with the goal of minimizing internal stresses and improving durability. The latter portion of this review recounts these developments in polymeric heart valves, with a focus on mechanical testing of polymers, valve geometry, and manufacturing methods.
Collapse
Affiliation(s)
- Richard L Li
- Department of Mechanical Engineering, Fu Foundation School of Engineering and Applied Science, Columbia University, New York, NY, USA; Division of Cardiac, Thoracic and Vascular Surgery, Section of Pediatric and Congenital Cardiac Surgery, New-York Presbyterian - Morgan Stanley Children's Hospital, Columbia University Medical Center, New York, NY, USA
| | - Jonathan Russ
- Department of Civil Engineering and Engineering Mechanics, Fu Foundation School of Engineering and Applied Science, Columbia University, New York, NY, USA
| | - Costas Paschalides
- Department of Mechanical Engineering, Fu Foundation School of Engineering and Applied Science, Columbia University, New York, NY, USA
| | - Giovanni Ferrari
- Department of Surgery and Biomedical Engineering, Columbia University Medical Center, New York, NY, USA
| | - Haim Waisman
- Department of Civil Engineering and Engineering Mechanics, Fu Foundation School of Engineering and Applied Science, Columbia University, New York, NY, USA
| | - Jeffrey W Kysar
- Department of Mechanical Engineering, Fu Foundation School of Engineering and Applied Science, Columbia University, New York, NY, USA; Department of Otolaryngology - Head and Neck Surgery, Columbia University Medical Center, New York, NY, USA.
| | - David Kalfa
- Division of Cardiac, Thoracic and Vascular Surgery, Section of Pediatric and Congenital Cardiac Surgery, New-York Presbyterian - Morgan Stanley Children's Hospital, Columbia University Medical Center, New York, NY, USA.
| |
Collapse
|
9
|
Gasparotti E, Vignali E, Losi P, Scatto M, Fanni BM, Soldani G, Landini L, Positano V, Celi S. A 3D printed melt-compounded antibiotic loaded thermoplastic polyurethane heart valve ring design: an integrated framework of experimental material tests and numerical simulations. INT J POLYM MATER PO 2018. [DOI: 10.1080/00914037.2018.1525717] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Affiliation(s)
- Emanuele Gasparotti
- BioCardioLab, Bioengineering Unit, Fondazione Toscana Gabriele Monasterio, Massa, Italy
| | - Emanuele Vignali
- BioCardioLab, Bioengineering Unit, Fondazione Toscana Gabriele Monasterio, Massa, Italy
- Department of Information Engineering, University of Pisa, Pisa, Italy
| | - Paola Losi
- Biomaterial Laboratory, Institute of Clinical Physiology CNR, Massa, Italy
| | - Marco Scatto
- Nadir S.r.l., c/o Campus Scientifico Università Ca’ Foscari Venezia, Venezia, Italy
| | - Benigno Marco Fanni
- BioCardioLab, Bioengineering Unit, Fondazione Toscana Gabriele Monasterio, Massa, Italy
| | - Giorgio Soldani
- Biomaterial Laboratory, Institute of Clinical Physiology CNR, Massa, Italy
| | - Luigi Landini
- Department of Information Engineering, University of Pisa, Pisa, Italy
| | - Vincenzo Positano
- BioCardioLab, Bioengineering Unit, Fondazione Toscana Gabriele Monasterio, Massa, Italy
| | - Simona Celi
- BioCardioLab, Bioengineering Unit, Fondazione Toscana Gabriele Monasterio, Massa, Italy
| |
Collapse
|
10
|
Luraghi G, Wu W, De Gaetano F, Rodriguez Matas JF, Moggridge GD, Serrani M, Stasiak J, Costantino ML, Migliavacca F. Evaluation of an aortic valve prosthesis: Fluid-structure interaction or structural simulation? J Biomech 2017; 58:45-51. [PMID: 28454910 PMCID: PMC5473331 DOI: 10.1016/j.jbiomech.2017.04.004] [Citation(s) in RCA: 51] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2016] [Revised: 03/23/2017] [Accepted: 04/09/2017] [Indexed: 01/31/2023]
Abstract
Bio-inspired polymeric heart valves (PHVs) are excellent candidates to mimic the structural and the fluid dynamic features of the native valve. PHVs can be implanted as prosthetic alternative to currently clinically used mechanical and biological valves or as potential candidate for a minimally invasive treatment, like the transcatheter aortic valve implantation. Nevertheless, PHVs are not currently used for clinical applications due to their lack of reliability. In order to investigate the main features of this new class of prostheses, pulsatile tests in an in-house pulse duplicator were carried out and reproduced in silico with both structural Finite-Element (FE) and Fluid-Structure interaction (FSI) analyses. Valve kinematics and geometric orifice area (GOA) were evaluated to compare the in vitro and the in silico tests. Numerical results showed better similarity with experiments for the FSI than for the FE simulations. The maximum difference between experimental and FSI GOA at maximum opening time was only 5%, as compared to the 46.5% between experimental and structural FE GOA. The stress distribution on the valve leaflets clearly reflected the difference in valve kinematics. Higher stress values were found in the FSI simulations with respect to those obtained in the FE simulation. This study demonstrates that FSI simulations are more appropriate than FE simulations to describe the actual behaviour of PHVs as they can replicate the valve-fluid interaction while providing realistic fluid dynamic results.
Collapse
Affiliation(s)
- Giulia Luraghi
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | - Wei Wu
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | - Francesco De Gaetano
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | - Josè Felix Rodriguez Matas
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | - Geoff D Moggridge
- Department of Chemical Engineering and Biotechnology, University of Cambridge, Cambridge, UK
| | - Marta Serrani
- Department of Chemical Engineering and Biotechnology, University of Cambridge, Cambridge, UK
| | - Joanna Stasiak
- Department of Chemical Engineering and Biotechnology, University of Cambridge, Cambridge, UK
| | - Maria Laura Costantino
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | - Francesco Migliavacca
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy.
| |
Collapse
|
11
|
Bozkurt S, Preston-Maher GL, Torii R, Burriesci G. Design, Analysis and Testing of a Novel Mitral Valve for Transcatheter Implantation. Ann Biomed Eng 2017; 45:1852-1864. [PMID: 28374279 PMCID: PMC5527080 DOI: 10.1007/s10439-017-1828-2] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2016] [Accepted: 03/25/2017] [Indexed: 12/31/2022]
Abstract
Mitral regurgitation is a common mitral valve dysfunction which may lead to heart failure. Because of the rapid aging of the population, conventional surgical repair and replacement of the pathological valve are often unsuitable for about half of symptomatic patients, who are judged high-risk. Transcatheter valve implantation could represent an effective solution. However, currently available aortic valve devices are inapt for the mitral position. This paper presents the design, development and hydrodynamic assessment of a novel bi-leaflet mitral valve suitable for transcatheter implantation. The device consists of two leaflets and a sealing component made from bovine pericardium, supported by a self-expanding wireframe made from superelastic NiTi alloy. A parametric design procedure based on numerical simulations was implemented to identify design parameters providing acceptable stress levels and maximum coaptation area for the leaflets. The wireframe was designed to host the leaflets and was optimised numerically to minimise the stresses for crimping in an 8 mm sheath for percutaneous delivery. Prototypes were built and their hydrodynamic performances were tested on a cardiac pulse duplicator, in compliance with the ISO5840-3:2013 standard. The numerical results and hydrodynamic tests show the feasibility of the device to be adopted as a transcatheter valve implant for treating mitral regurgitation.
Collapse
Affiliation(s)
- Selim Bozkurt
- UCL Mechanical Engineering, Cardiovascular Engineering Laboratory, University College London, London, WC1E 7JE, UK
| | - Georgia L Preston-Maher
- UCL Mechanical Engineering, Cardiovascular Engineering Laboratory, University College London, London, WC1E 7JE, UK
| | - Ryo Torii
- UCL Mechanical Engineering, Cardiovascular Engineering Laboratory, University College London, London, WC1E 7JE, UK
| | - Gaetano Burriesci
- UCL Mechanical Engineering, Cardiovascular Engineering Laboratory, University College London, London, WC1E 7JE, UK. .,Ri.MED Foundation, Bioengineering Group, Palermo, Italy.
| |
Collapse
|
12
|
Serrani M, Brubert J, Stasiak J, De Gaetano F, Zaffora A, Costantino ML, Moggridge GD. A Computational Tool for the Microstructure Optimization of a Polymeric Heart Valve Prosthesis. J Biomech Eng 2016; 138:061001. [PMID: 27018454 DOI: 10.1115/1.4033178] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2015] [Indexed: 11/08/2022]
Abstract
Styrene-based block copolymers are promising materials for the development of a polymeric heart valve prosthesis (PHV), and the mechanical properties of these polymers can be tuned via the manufacturing process, orienting the cylindrical domains to achieve material anisotropy. The aim of this work is the development of a computational tool for the optimization of the material microstructure in a new PHV intended for aortic valve replacement to enhance the mechanical performance of the device. An iterative procedure was implemented to orient the cylinders along the maximum principal stress direction of the leaflet. A numerical model of the leaflet was developed, and the polymer mechanical behavior was described by a hyperelastic anisotropic constitutive law. A custom routine was implemented to align the cylinders with the maximum principal stress direction in the leaflet for each iteration. The study was focused on valve closure, since during this phase the fibrous structure of the leaflets must bear the greatest load. The optimal microstructure obtained by our procedure is characterized by mainly circumferential orientation of the cylinders within the valve leaflet. An increase in the radial strain and a decrease in the circumferential strain due to the microstructure optimization were observed. Also, a decrease in the maximum value of the strain energy density was found in the case of optimized orientation; since the strain energy density is a widely used criterion to predict elastomer's lifetime, this result suggests a possible increase of the device durability if the polymer microstructure is optimized. The present method represents a valuable tool for the design of a new anisotropic PHV, allowing the investigation of different designs, materials, and loading conditions.
Collapse
|
13
|
Brubert J, Krajewski S, Wendel HP, Nair S, Stasiak J, Moggridge GD. Hemocompatibility of styrenic block copolymers for use in prosthetic heart valves. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2016; 27:32. [PMID: 26704549 PMCID: PMC4690832 DOI: 10.1007/s10856-015-5628-7] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/26/2015] [Accepted: 11/12/2015] [Indexed: 06/05/2023]
Abstract
Certain styrenic thermoplastic block copolymer elastomers can be processed to exhibit anisotropic mechanical properties which may be desirable for imitating biological tissues. The ex-vivo hemocompatibility of four triblock (hard-soft-hard) copolymers with polystyrene hard blocks and polyethylene, polypropylene, polyisoprene, polybutadiene or polyisobutylene soft blocks are tested using the modified Chandler loop method using fresh human blood and direct contact cell proliferation of fibroblasts upon the materials. The hemocompatibility and durability performance of a heparin coating is also evaluated. Measures of platelet and coagulation cascade activation indicate that the test materials are superior to polyester but inferior to expanded polytetrafluoroethylene and bovine pericardium reference materials. Against inflammatory measures the test materials are superior to polyester and bovine pericardium. The addition of a heparin coating results in reduced protein adsorption and ex-vivo hemocompatibility performance superior to all reference materials, in all measures. The tested styrenic thermoplastic block copolymers demonstrate adequate performance for blood contacting applications.
Collapse
Affiliation(s)
- Jacob Brubert
- Department of Chemical Engineering and Biotechnology, University of Cambridge, Cambridge, UK.
| | - Stefanie Krajewski
- Department of Thoracic and Cardiovascular Surgery, University Medical Center Tuebingen, Tübingen, Germany
| | - Hans Peter Wendel
- Department of Thoracic and Cardiovascular Surgery, University Medical Center Tuebingen, Tübingen, Germany
| | - Sukumaran Nair
- Cardiothoracic Services, Freeman Hospital, Newcastle, UK
| | - Joanna Stasiak
- Department of Chemical Engineering and Biotechnology, University of Cambridge, Cambridge, UK
| | - Geoff D Moggridge
- Department of Chemical Engineering and Biotechnology, University of Cambridge, Cambridge, UK
| |
Collapse
|