A prospective multicentre diagnostic accuracy study for the Truenat tuberculosis assays.
Eur Respir J 2021;
58:13993003.00526-2021. [PMID:
34049948 PMCID:
PMC8607906 DOI:
10.1183/13993003.00526-2021]
[Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Accepted: 03/29/2021] [Indexed: 11/26/2022]
Abstract
Background
Bringing reliable and accurate tuberculosis (TB) diagnosis closer to patients is a key priority for global TB control. Molbio Diagnostics have developed the Truenat point-of-care molecular assays for detection of TB and rifampicin (RIF) resistance.
Methods
We conducted a prospective multicentre diagnostic accuracy study at 19 primary healthcare centres and seven reference laboratories in Peru, India, Ethiopia and Papua New Guinea to estimate the diagnostic accuracy of the point-of-care Truenat MTB, MTB Plus and MTB-RIF Dx assays for pulmonary TB using culture and phenotypic drug susceptibility testing as the reference standard, compared with Xpert MTB/RIF or Ultra.
Results
Of 1807 enrolled participants with TB signs/symptoms, 24% were culture-positive for Mycobacterium tuberculosis, of which 15% were RIF-resistant. In microscopy centres, the pooled sensitivity of Truenat MTB and Truenat MTB Plus was 73% (95% CI 67–78%) and 80% (95% CI 75–84%), respectively. Among smear-negative specimens, sensitivities were 36% (95% CI 27–47%) and 47% (95% CI 37–58%), respectively. Sensitivity of Truenat MTB-RIF was 84% (95% CI 62–95%). Truenat assays showed high specificity. Head-to-head comparison in the central reference laboratories suggested that the Truenat assays have similar performance to Xpert MTB/RIF.
Conclusion
We found the performance of Molbio's Truenat MTB, MTB Plus and MTB-RIF Dx assays to be comparable to that of the Xpert MTB/RIF assay. Performing the Truenat tests in primary healthcare centres with very limited infrastructure was feasible. These data supported the development of a World Health Organization policy recommendation of the Molbio assays.
Diagnostic performance of point-of-care Truenat assays in primary healthcare centres is comparable to that of Xpert MTB/RIF placed in reference laboratories. The WHO now recommends Truenat as an initial test for detection of TB and RIF resistance.https://bit.ly/31Wj3S6
Collapse