1
|
Jindanil T, Xu L, Fontenele RC, Perula MCDL, Jacobs R. Smartphone applications for facial scanning: A technical and scoping review. Orthod Craniofac Res 2024. [PMID: 38842250 DOI: 10.1111/ocr.12821] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/27/2024] [Indexed: 06/07/2024]
Abstract
INTRODUCTION Facial scanning through smartphone scanning applications (SSA) is increasingly being used for medical applications as cost-effective, chairside method. However, clinical validation is lacking. This review aims to address: (1) Which SSA could perform facial scanning? (2) Which SSA can be clinically used? (3) Which SSA have been reported and scientifically validated for medical applications? METHODS Technical search for SSA designed for face or object scanning was conducted on Google, Apple App Store, and Google Play Store from August 2022 to December 2023. Literature search was performed on PubMed, Cochrane, EMBASE, MEDLINE, Scopus, IEEE Xplore, ACM Digital Library, Clinicaltrials.gov, ICTRP (WHO) and preprints up to 2023. Eligibility criteria included English-written scientific articles incorporating at least one SSA for clinical purposes. SSA selection and data extraction were executed by one reviewer, validated by second, with third reviewer being consulted for discordances. RESULTS Sixty-three applications designed for three-dimensional object scanning were retrieved, with 52 currently offering facial scanning capabilities. Fifty-six scientific articles, comprising two case reports, 16 proof-of-concepts and 38 experimental studies were analysed. Thirteen applications (123D Catch, 3D Creator, Bellus 3D Dental Pro, Bellus 3D Face app, Bellus 3D Face Maker, Capture, Heges, Metascan, Polycam, Scandy Pro, Scaniverse, Tap tap tap and Trnio) were reported in literature for digital workflow integration, comparison or proof-of-concept studies. CONCLUSION Fifty-two SSA can perform facial scanning currently and can be used clinically, offering cost-effectiveness, portability and user-friendliness. Although clinical validation is crucial, only 13 SSA were scientifically validated, underlying awareness of potential pitfalls and limitations.
Collapse
Affiliation(s)
- Thanatchaporn Jindanil
- OMFS-IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven, Leuven, Belgium
| | - Lianyi Xu
- OMFS-IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven, Leuven, Belgium
- Department of Stomatology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | | | - Maria Cadenas de Llano Perula
- Department of Oral Health Sciences - Orthodontics, KU Leuven and Dentistry, University Hospitals Leuven, Leuven, Belgium
| | - Reinhilde Jacobs
- OMFS-IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven, Leuven, Belgium
- Department of Dental Medicine, Karolinska Institute, Stockholm, Sweden
| |
Collapse
|
2
|
Hobbs-Murphy K, Olmedo-Nockideneh I, Brazile WJ, Morris K, Rosecrance J. Intra-rater and inter-rater reliability of 3D facial measurements. APPLIED ERGONOMICS 2024; 116:104218. [PMID: 38181456 DOI: 10.1016/j.apergo.2023.104218] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Revised: 11/30/2023] [Accepted: 12/21/2023] [Indexed: 01/07/2024]
Abstract
Three-dimensional (3D) body scanning technology has applications for obtaining anthropometric data in human-centered and product development fields. The reliability of 3D measurements gathered from 3D scans must be assessed to understand the degree to which this technology is appropriate for use in place of manual anthropometric methods. The intra- and inter-rater reliabilities of 3D facial measurements were assessed among four novice raters using 3D landmarking. Intraclass correlation coefficient (ICC) statistics were calculated for the 3D measurement data collected in three phases to assess baseline reliabilities and improvements in reliabilities as the result of additional training and experience. Based on the results of this study, the researchers found that the collection of 3D measurement data, by multiple raters and using 3D landmarking methods, yielded a high percentage of ICC statistics in the good to excellent (>0.75 ICC) reliability range. Rater training and experience were important considerations in improving intra- and inter-rater reliabilities.
Collapse
Affiliation(s)
- Kayna Hobbs-Murphy
- Department of Design and Merchandising, Colorado State University, 1574 Campus Delivery, Fort Collins, CO, 80523-1574, United States.
| | - Isabel Olmedo-Nockideneh
- Department of Environmental and Radiological Health Sciences, Colorado State University, 1681 Campus Delivery, Fort Collins, CO, 80523-1681, United States
| | - William J Brazile
- Department of Environmental and Radiological Health Sciences, Colorado State University, 1681 Campus Delivery, Fort Collins, CO, 80523-1681, United States
| | - Kristen Morris
- Department of Design and Merchandising, Colorado State University, 1574 Campus Delivery, Fort Collins, CO, 80523-1574, United States
| | - John Rosecrance
- Department of Environmental and Radiological Health Sciences, Colorado State University, 1681 Campus Delivery, Fort Collins, CO, 80523-1681, United States
| |
Collapse
|
3
|
König J, Kelemen K, Czumbel LM, Szabó B, Varga G, Borbély J, Németh O, Hegyi P, Hermann P. Current status of optical scanning in facial prosthetics: A systematic review and meta-analysis. J Prosthodont Res 2024; 68:1-11. [PMID: 37286516 DOI: 10.2186/jpr.jpr_d_22_00221] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Purpose To assess the accuracy of scanning technologies for constructing facial prostheses on human faces.Study selection Our systematic search was performed on five databases. Studies reporting on human volunteers (P) whose faces were scanned with a scanning technology were eligible. The anthropometrical interlandmark distances (ILDs) were used as indicators of accuracy; the ILDs are measured on the virtual models (I) and directly on the faces (C). The virtual models deviated from their true values (O). Studies reporting the measurements on patients with or without facial deformities were included, but cadavers or inanimate objects were reasons for exclusion. We performed a mean difference (MD) / standardized MD analysis with a random effect model. The difficulties regarding the scanning procedure mentioned in the articles were also assessed.Results We found 3723 records after duplicate removal. Twenty five articles were eligible for the qualitative review, and ten articles were included in the quantitative synthesis. Eight different ILDs were compared in MD analyses. The differences were between -0.54-0.43 mm. We also performed a regional three-dimensional analysis to compare scanning technologies in each major region. No significant differences were found in any of the regions and axes. The most mentioned difficulties were artifacts due to motion or blinking.Conclusions The results suggest no systematic skew in linear dimensions neither between direct caliper measurements nor between measurements on the scanned models, scanning technologies, or facial regions.
Collapse
Affiliation(s)
- János König
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| | - Kata Kelemen
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| | - László Márk Czumbel
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
- Department of Periodontology, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
| | - Bence Szabó
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| | - Gábor Varga
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
- Department of Oral Biology, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
| | - Judit Borbély
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| | - Orsolya Németh
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
- Department for Community Dentistry, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
| | - Péter Hegyi
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
- Division of Pancreatic Diseases, Heart and Vascular Center, Semmelweis University, Budapest, Hungary
- Institute for Translational Medicine, Medical School, University of Pécs, Pécs, Hungary
| | - Péter Hermann
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| |
Collapse
|
4
|
Park M, Mai HN, Mai MY, Win TT, Lee DH, Lee CH. Intra- and Interrater Agreement of Face Esthetic Analysis in 3D Face Images. BIOMED RESEARCH INTERNATIONAL 2023; 2023:3717442. [PMID: 37078008 PMCID: PMC10110378 DOI: 10.1155/2023/3717442] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/12/2022] [Revised: 09/21/2022] [Accepted: 01/25/2023] [Indexed: 04/21/2023]
Abstract
The use of three-dimensional (3D) facial scans for facial analysis is increasing in maxillofacial treatment. The aim of this study was to investigate the consistency of two-dimensional (2D) and 3D facial analyses performed by multiple raters. Six men and four women (25-36-year-old) participated in this study. The 2D images of the smiling and resting faces in the frontal and sagittal planes were obtained. The 3D facial and intraoral scans were merged to generate virtual 3D faces. Ten clinicians performed facial analyses by investigating 14 indices of 2D and 3D faces. Intra- and interrater agreements of the results of 2D and 3D facial analyses within and among the participants were evaluated. The intrarater agreement between the 2D and 3D facial analyses varied according to the indices. The highest and lowest agreements were found for the dental crowding index (0.94) and smile line curvature index (0.56) in the frontal plane, and Angle's classification (canine) index (0.98) and occlusal plane angle index (0.55) in the profile plane. In the frontal plane, the interrater agreements were generally higher for the 3D images than for the 2D images, while in the profile plane, the interrater agreements were high in the Angle's classification (canine) index however low in the other indices. Several occlusion-related indices were missing in the 2D images because the posterior teeth were not observed. Esthetic analysis results between 2D and 3D face images can differ according to the evaluation indices. The use of 3D faces is recommended over 2D images to increase the reliability of facial analyses, as it can fully assess both esthetic and occlusion-related indices.
Collapse
Affiliation(s)
- Minsoo Park
- Department of Prosthodontics, School of Dentistry, Kyungpook National University, 2177 Dalgubeoldae-ro, Jung-Gu, Daegu 41940, Republic of Korea
| | - Hang-Nga Mai
- Dental School of Hanoi University of Business and Technology, 10000 Hanoi, Vietnam
- Institute for Translational Research in Dentistry, Kyungpook National University, 2177 Dalgubeoldae-ro, Jung-Gu, Daegu 41940, Republic of Korea
| | - Mai Yen Mai
- Department of Prosthodontics, School of Dentistry, Kyungpook National University, 2177 Dalgubeoldae-ro, Jung-Gu, Daegu 41940, Republic of Korea
| | - Thaw Thaw Win
- Department of Prosthodontics, School of Dentistry, Kyungpook National University, 2177 Dalgubeoldae-ro, Jung-Gu, Daegu 41940, Republic of Korea
| | - Du-Hyeong Lee
- Department of Prosthodontics, School of Dentistry, Kyungpook National University, 2177 Dalgubeoldae-ro, Jung-Gu, Daegu 41940, Republic of Korea
- Institute for Translational Research in Dentistry, Kyungpook National University, 2177 Dalgubeoldae-ro, Jung-Gu, Daegu 41940, Republic of Korea
| | - Cheong-Hee Lee
- Department of Prosthodontics, School of Dentistry, Kyungpook National University, 2177 Dalgubeoldae-ro, Jung-Gu, Daegu 41940, Republic of Korea
| |
Collapse
|
5
|
Pan F, Liu J, Cen Y, Chen Y, Cai R, Zhao Z, Liao W, Wang J. Accuracy of RGB-D camera-based and stereophotogrammetric facial scanners: a comparative study. J Dent 2022; 127:104302. [PMID: 36152954 DOI: 10.1016/j.jdent.2022.104302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Revised: 09/05/2022] [Accepted: 09/20/2022] [Indexed: 12/14/2022] Open
Abstract
OBJECTIVES This study aimed to evaluate and compare the accuracy and inter-operator reliability of a low-cost red-green-blue-depth (RGB-D) camera-based facial scanner (Bellus3D Arc7) with a stereophotogrammetry facial scanner (3dMD) and to explore the possibility of the former as a clinical substitute for the latter. METHODS A mannequin head was selected as the research object. In the RGB-D camera-based facial scanner group, the head was continuously scanned five times using an RGB-D camera-based facial scanner (Bellus3D Arc7), and the outcome data of each scan was then imported into CAD software (MeshLab) to reconstruct three-dimensional (3D) facial photographs. In the stereophotogrammetry facial scanner group, the mannequin head was scanned with a stereophotogrammetry facial scanner (3dMD). Selected parameters were directly measured on the reconstructed 3D virtual faces using a CAD software. The same parameters were then measured directly on the mannequin head using the direct anthropometry (DA) method as the gold standard for later comparison. The accuracy of the facial scanners was evaluated in terms of trueness and precision. Trueness was evaluated by comparing the measurement results of the two groups with each other and with that of DA using equivalence tests and average absolute deviations, while precision and inter-operator reliability were assessed using the intraclass correlation coefficient (ICC). A 3D facial mesh deviation between the two groups was also calculated for further reference using a 3D metrology software (GOM inspect pro). RESULTS In terms of trueness, the average absolute deviations between RGB-D camera-based and stereophotogrammetry facial scanners, between RGB-D camera-based facial scanner and DA, and between stereophotogrammetry facial scanner and DA were statistically equivalent at 0.50±0.27 mm, 0.61±0.42 mm, and 0.28±0.14 mm, respectively. Equivalence test results confirmed that their equivalence was within clinical requirements (<1 mm). The ICC for each parameter was approximately 0.999 in terms of precision and inter-operator reliability. A 3D facial mesh analysis suggested that the deviation between the two groups was 0.37±0.01 mm. CONCLUSIONS For facial scanners, an accuracy of <1 mm is commonly considered clinically acceptable. Both the RGB-D camera-based and stereophotogrammetry facial scanners in this study showed acceptable trueness, high precision, and inter-operator reliability. A low-cost RGB-D camera-based facial scanner could be an eligible clinical substitute for traditional stereophotogrammetry. CLINICAL SIGNIFICANCE The low-cost RGB-D camera-based facial scanner showed clinically acceptable trueness, high precision, and inter-operator reliability; thus, it could be an eligible clinical substitute for traditional stereophotogrammetry.
Collapse
Affiliation(s)
- Fangwei Pan
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, China
| | - Jialing Liu
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, China
| | - Yueyan Cen
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Ye Chen
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Ruilie Cai
- Department of Epidemiology and Biostatistics, Arnold School of Public Health, University of South Carolina, South Carolina, United States
| | - Zhihe Zhao
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, China
| | - Wen Liao
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, China.
| | - Jian Wang
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, China.
| |
Collapse
|
6
|
Cao R, Chen B, Xu H, Cai Y, Liu W. Accuracy of three-dimensional optical devices for facial soft-tissue measurement in clinical practice of stomatology: A PRISMA systematic review. Medicine (Baltimore) 2022; 101:e31922. [PMID: 36451461 PMCID: PMC9704975 DOI: 10.1097/md.0000000000031922] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Accepted: 10/31/2022] [Indexed: 12/02/2022] Open
Abstract
BACKGROUND The accuracy of 3-dimensional (3D) optical devices for facial soft-tissue measurement is essential to the success of clinical treatment in stomatology. The aim of the present systematic review was to summarize the accuracy of 3D optical devices used for facial soft-tissue assessment in stomatology. METHODS An extensive systematic literature search was performed in the PubMed/MEDLINE, Embase, Scopus and Cochrane Library databases for studies published in the English language up to May 2022 in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. Peer-reviewed journal articles evaluating the facial soft-tissue morphology by 3D optical devices were included. The risk of bias was performed using the Quality Assessment Tool for Diagnostic Accuracy Studies-2 guidelines by the 2 reviewers. The potential publication bias was analyzed using the Review Manager software. RESULTS The query returned 1853 results. A total of 38 studies were included in this review. Articles were categorized based on the principle of devices: laser-based scanning, structured-light scanning, stereophotogrammetry and red, green, blue-depth camera. CONCLUSION Overall, the 3D optical devices demonstrated excellent accuracy and reliability for facial soft-tissue measurement in stomatology. red, green, blue-depth camera can collect accurate static and dynamic 3D facial scans with low cost and high measurement accuracy. Practical needs and availability of resources should be considered when these devices are used in clinical settings.
Collapse
Affiliation(s)
- Rongkai Cao
- School and Hospital of Stomatology, Tongji University, Shanghai Engineering Research Center of Tooth Restoration and Regeneration, Shanghai, China
| | - Beibei Chen
- School and Hospital of Stomatology, Tongji University, Shanghai Engineering Research Center of Tooth Restoration and Regeneration, Shanghai, China
| | - Hui Xu
- School and Hospital of Stomatology, Tongji University, Shanghai Engineering Research Center of Tooth Restoration and Regeneration, Shanghai, China
| | - Yiyi Cai
- School and Hospital of Stomatology, Tongji University, Shanghai Engineering Research Center of Tooth Restoration and Regeneration, Shanghai, China
| | - Weicai Liu
- School and Hospital of Stomatology, Tongji University, Shanghai Engineering Research Center of Tooth Restoration and Regeneration, Shanghai, China
| |
Collapse
|
7
|
Facial Scanning Accuracy with Stereophotogrammetry and Smartphone Technology in Children: A Systematic Review. CHILDREN 2022; 9:children9091390. [PMID: 36138698 PMCID: PMC9498045 DOI: 10.3390/children9091390] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/29/2022] [Revised: 09/03/2022] [Accepted: 09/12/2022] [Indexed: 12/23/2022]
Abstract
The aim of the study was to systematically review and compare the accuracy of smartphone scanners versus stereophotogrammetry technology for facial digitization in children. A systematic literature search strategy of articles published from 1 January 2010 to 30 August 2022 was adopted through a combination of Mesh terms and free text words pooled through boolean operators on the following databases: PubMed, Scopus, Web of Science, Cochrane Library, LILACS, and OpenGrey. Twenty-three articles met the inclusion criteria. Stationary stereophotogrammetry devices showed a mean accuracy that ranged from 0.087 to 0.860 mm, portable stereophotogrammetry scanners from 0.150 to 0.849 mm, and smartphones from 0.460 to 1.400 mm. Regarding the risk of bias assessment, fourteen papers showed an overall low risk, three articles had unclear risk and four articles had high risk. Although smartphones showed less performance on deep and irregular surfaces, all the analyzed devices were sufficiently accurate for clinical application. Internal depth-sensing cameras or external infrared structured-light depth-sensing cameras plugged into smartphones/tablets increased the accuracy. These devices are portable and inexpensive but require greater operator experience and patient compliance for the incremented time of acquisition. Stationary stereophotogrammetry is the gold standard for greater accuracy and shorter acquisition time, avoiding motion artifacts.
Collapse
|
8
|
Antonacci D, Caponio VCA, Troiano G, Pompeo MG, Gianfreda F, Canullo L. Facial scanning technologies in the era of digital workflow: A systematic review and network meta-analysis. J Prosthodont Res 2022. [PMID: 36058870 DOI: 10.2186/jpr.jpr_d_22_00107] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
PURPOSE The aim of this network meta-analysis is to evaluate the accuracy of various face-scanning technologies in the market, with respect to the different dimensions of space (x, y, and z axes). Furthermore, attention will be paid to the type of technologies currently used and to the best practices for high-quality scan acquisition. MATERIAL AND METHODS The review was conducted following the PRISMA guidelines and its updates. A thorough search was performed using the digital databases MEDLINE, PubMed, EMBASE, and the Cochrane Central Register of Controlled Trials by entering research lines or various combinations of free words. The main keywords used during the search process were "photogrammetry", "laser scanner", "optical scanner", "3D, and "face". RESULTS None of the included technologies significantly deviated from direct anthropometry. The obtained mean differences in the distances between the considered landmarks range from 1.10 to -1.74 mm. CONCLUSION Limiting the movements of the patient and scanner allows for more accurate facial scans with all the technologies involved. Active technologies such as laser scanners (LS), structured light (SL), and infrared structured light (ISL) have accuracy comparable to that of static stereophotogrammetry while being more cost-effective and less time-consuming.
Collapse
Affiliation(s)
| | | | - Giuseppe Troiano
- Department of Clinical and Experimental Medicine, University of Foggia, Foggia, Italy
| | | | - Francesco Gianfreda
- Department of Industrial Engineering, University of Rome "Tor Vergata", Rome, Italy
| | - Luigi Canullo
- Department of Periodontology, University of Bern, Switzerland
| |
Collapse
|
9
|
Lim YC, Abdul Shakor AS, Shaharudin R. Reliability and Accuracy of 2D Photogrammetry: A Comparison With Direct Measurement. Front Public Health 2022; 9:813058. [PMID: 35155360 PMCID: PMC8826070 DOI: 10.3389/fpubh.2021.813058] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Accepted: 12/06/2021] [Indexed: 11/13/2022] Open
Abstract
Objective Facial anthropometric data is important for the design of respirators. Two-dimensional (2D) photogrammetry has replaced direct anthropometric method, but the reliability and accuracy of 2D photogrammetry has not been quantified. This study aimed to assess inter-rater reliability of 2D photogrammetry and to examine the reliability and accuracy of 2D photogrammetry with direct measurement. Design A cross-sectional study. Setting Malaysia. Participants A subset of 96 participants aged 18 and above. Primary and secondary outcomes Ten facial dimensions were measured using direct measurement and 2D photogrammetry. An assessment of inter-rater reliability was performed using intra-class correlation (ICC) of the 2D images. In addition, ICC and Bland-Altman analyses were used to assess the reliability and agreement of 2D photogrammetry with direct measurement. Results Except for head breadth and bigonial breadth, which were also found to have low inter-rater reliability, there was no significant difference in the inter-rater mean value of the 2D photogrammetry. The mean measurements derived from direct measurement and 2D photogrammetry were mostly similar. However, statistical differences were noted for two facial dimensions, i.e., bizygomatic breadth and bigonial breadth, and clinically the magnitude of difference was also significant. There were no statistical differences in respect to the remaining eight facial dimensions, where the smallest mean difference was 0.3 mm and biggest mean difference was 1.0 mm. The ICC showed head breadth had poor reliability, whilst Bland-Altman analyses showed seven out of 10 facial dimensions using 2D photogrammetry were accurate, as compared to direct measurement. Conclusion Only certain facial measurements can be reliably and accurately measured using 2D photogrammetry, thus it is important to conduct a reliability and validation study before the use of any measurement methods in anthropometric studies. The results of this study also suggest that 2D photogrammetry can be used to supplement direct measurement for certain facial dimensions.
Collapse
Affiliation(s)
- Yin Cheng Lim
- Environmental Health Research Centre, Institute for Medical Research, National Institutes of Health, Ministry of Health of Malaysia, Shah Alam, Malaysia.,Faculty of Medicine, Department of Social and Preventive Medicine, University of Malaya, Kuala Lumpur, Malaysia
| | - Ameerah Su'ad Abdul Shakor
- Environmental Health Research Centre, Institute for Medical Research, National Institutes of Health, Ministry of Health of Malaysia, Shah Alam, Malaysia
| | - Rafiza Shaharudin
- Environmental Health Research Centre, Institute for Medical Research, National Institutes of Health, Ministry of Health of Malaysia, Shah Alam, Malaysia
| |
Collapse
|
10
|
Hao K, Luo J, Di P, Zhang Y, Lin Y. Morphometry and displacement analysis of the upper lips following maxillary full-arch implant-supported fixed prostheses: a 3D morphometric study. BMC Oral Health 2021; 21:461. [PMID: 34556104 PMCID: PMC8459564 DOI: 10.1186/s12903-021-01838-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2021] [Accepted: 09/16/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND With the emergence of three-dimensional (3D) integration technology, analysis of soft tissue displacement and morphological changes after maxillary full-arch implant-supported fixed prostheses can be performed. The aim of this study was to verify the feasibility of the 3D integration method for constructing the relative position of the prostheses and facial soft tissue, evaluate the displacement and morphological variation of the upper lips after maxillary full-arch implant-supported fixed prostheses. METHODS Twenty-five maxillary edentulous patients were recruited in this study. At the time of final prosthesis delivery, the 3D prostheses data and three 3D facial profiles were integrated. After method validation, the 3D position changes of seven soft tissue landmarks were used to reflect the 25 upper lips. The variation of four morphological distances were analyzed to reflect the morphological alteration of the upper lips. Two pairs of dentofacial landmarks were used to analyze the sagittal relative position of the prostheses and soft tissue. The included patients were also grouped to determine the impact of sex, upper lip thickness, and length on lip support changes. RESULTS The average distance of the two matched relative reliable forehead regions was only 0.32 mm. The sagittal shifts of labrale superius (LS), stomion (STO), crista philtri left (CPHL) and crista philtri right (CPHR) were 3.44 ± 1.39 mm, 2.52 ± 1.38 mm, 3.04 ± 1.18 mm, and 3.12 ± 1.21 mm, respectively. With the exception of the decrease in the length of subnasale (SN)-LS, the length of cheilion right (CHR)-cheilion left (CHL), CPHR-CPHL, and LS-STO significantly increased. The two pairs of dentofacial landmarks had strong positive movement correlations along the sagittal direction. Patients with thinner and longer lips showed more lip support than those with thicker and shorter lips by a clinically insignificant amount. CONCLUSIONS The integration method of 3D facial and dental data showed high repeatability in constructing the dentofacial relative position. The linear equations reflecting dentofacial relative position could aid clinicians in evaluating the restoration effect and estimate the upper lip variation.
Collapse
Affiliation(s)
- Keyi Hao
- Department of Implantology, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, 22 Zhongguancun South Avenue, Haidian District, Beijing, 100081, People's Republic of China
| | - Jia Luo
- Department of Implantology, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, 22 Zhongguancun South Avenue, Haidian District, Beijing, 100081, People's Republic of China
| | - Ping Di
- Department of Implantology, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, 22 Zhongguancun South Avenue, Haidian District, Beijing, 100081, People's Republic of China
| | - Yu Zhang
- Department of Implantology, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, 22 Zhongguancun South Avenue, Haidian District, Beijing, 100081, People's Republic of China.
| | - Ye Lin
- Department of Implantology, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, 22 Zhongguancun South Avenue, Haidian District, Beijing, 100081, People's Republic of China.
| |
Collapse
|
11
|
Öztürk SA, Malkoç S, Yolcu Ü, İleri Z, Güler ÖÇ. Three-dimensional soft tissue evaluation after rapid maxillary expansion and mandibular midline distraction osteogenesis. Angle Orthod 2021; 91:634-640. [PMID: 33939817 DOI: 10.2319/122120-1023.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Accepted: 03/01/2021] [Indexed: 11/23/2022] Open
Abstract
OBJECTIVES To evaluate the effects of rapid maxillary expansion (RME) and mandibular midline distraction osteogenesis (MMDO) on facial soft tissues using three-dimensional (3D) images. MATERIALS AND METHODS A total of 20 patients (average age 15.86 ± 2.17 years) were treated with RME and MMDO using tooth-borne distractors. Three-dimensional photographs of each patient were taken with a stereophotogrammetry system at baseline (T0), at the end of the distraction period (T1), and at the end of the consolidation period (T2). All data were analyzed using a dependent-samples t-test at a significance level of 5%. RESULTS Total and lower face height increased after MMDO (P < .05). Nasal and mouth width increased after RME as compared with baseline (P < .05). The labiomental angle increased at T1 and decreased at T2 (P < .05). After MMDO, the convexity angle increased while the mandibular angle decreased (P < .05). Upper and lower lip angles increased after RME (P < .05). The distance from the lower lip to the E plane increased after MMDO and decreased after RME (P < .05). CONCLUSIONS The MMDO and RME procedures provide an efficient nonextraction treatment alternative for transverse maxillomandibular deficiency. MMDO may improve the facial soft tissue profile in the transverse and vertical axis of the mandibular region.
Collapse
|
12
|
Accuracy and Reproducibility of Facial Measurements of Digital Photographs and Wrapped Cone Beam Computed Tomography (CBCT) Photographs. Diagnostics (Basel) 2021; 11:diagnostics11050757. [PMID: 33922543 PMCID: PMC8147051 DOI: 10.3390/diagnostics11050757] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2021] [Revised: 04/18/2021] [Accepted: 04/21/2021] [Indexed: 11/17/2022] Open
Abstract
The study sought to assess whether the soft tissue facial profile measurements of direct Cone Beam Computed Tomography (CBCT) and wrapped CBCT images of non-standardized facial photographs are accurate compared to the standardized digital photographs. In this cross-sectional study, 60 patients with an age range of 18–30 years, who were indicated for CBCT, were enrolled. Two facial photographs were taken per patient: standardized and random (non-standardized). The non-standardized ones were wrapped with the CBCT images. The most used soft tissue facial profile landmarks/parameters (linear and angular) were measured on direct soft tissue three-dimensional (3D) images and on the photographs wrapped over the 3D-CBCT images, and then compared to the standardized photographs. The reliability analysis was performed using concordance correlation coefficients (CCC) and depicted graphically using Bland–Altman plots. Most of the linear and angular measurements showed high reliability (0.91 to 0.998). Nevertheless, four soft tissue measurements were unreliable; namely, posterior gonial angle (0.085 and 0.11 for wrapped and direct CBCT soft tissue, respectively), mandibular plane angle (0.006 and 0.0016 for wrapped and direct CBCT soft tissue, respectively), posterior facial height (0.63 and 0.62 for wrapped and direct CBCT soft tissue, respectively) and total soft tissue facial convexity (0.52 for both wrapped and direct CBCT soft tissue, respectively). The soft tissue facial profile measurements from either the direct 3D-CBCT images or the wrapped CBCT images of non-standardized frontal photographs were accurate, and can be used to analyze most of the soft tissue facial profile measurements.
Collapse
|
13
|
Shaheen E, Willaert R, Miclotte I, Coropciuc R, Bila M, Politis C. A novel fully automatic design approach of a 3D printed face specific mask: Proof of concept. PLoS One 2020; 15:e0243388. [PMID: 33270772 PMCID: PMC7720797 DOI: 10.1371/journal.pone.0243388] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Accepted: 11/20/2020] [Indexed: 11/30/2022] Open
Abstract
The use of high quality facemasks is indispensable in the light of the current COVID
pandemic. This study proposes a fully automatic technique to design a face specific mask.
Through the use of stereophotogrammetry, computer-assisted design and three-dimensional
(3D) printing, we describe a protocol for manufacturing facemasks perfectly adapted to the
individual face characteristics. The face specific mask was compared to a universal design
of facemask and different filter container’s designs were merged with the mask body.
Subjective assessment of the face specific mask demonstrated tight closure at the nose,
mouth and chin area, and permits the normal wearing of glasses. A screw-drive locking
system is advised for easy assembly of the filter components. Automation of the process
enables high volume production but still allows sufficient designer interaction to answer
specific requirements. The suggested protocol can be used to provide more comfortable,
effective and sustainable solution compared to a single use, standardized mask. Subsequent
research on printing materials, sterilization technique and compliance with international
regulations will facilitate the introduction of the face specific mask in clinical
practice as well as for general use.
Collapse
Affiliation(s)
- Eman Shaheen
- Department of Oral and Maxillofacial Surgery, University Hospitals Leuven,
Leuven, Belgium
- Department of Imaging and Pathology, OMFS IMPATH Research Group, Faculty of
Medicine, KU Leuven, Leuven, Belgium
- * E-mail:
| | - Robin Willaert
- Department of Oral and Maxillofacial Surgery, University Hospitals Leuven,
Leuven, Belgium
- Department of Imaging and Pathology, OMFS IMPATH Research Group, Faculty of
Medicine, KU Leuven, Leuven, Belgium
| | - Isabel Miclotte
- Department of Oral and Maxillofacial Surgery, University Hospitals Leuven,
Leuven, Belgium
- Department of Imaging and Pathology, OMFS IMPATH Research Group, Faculty of
Medicine, KU Leuven, Leuven, Belgium
| | - Ruxandra Coropciuc
- Department of Oral and Maxillofacial Surgery, University Hospitals Leuven,
Leuven, Belgium
- Department of Imaging and Pathology, OMFS IMPATH Research Group, Faculty of
Medicine, KU Leuven, Leuven, Belgium
| | - Michel Bila
- Department of Oral and Maxillofacial Surgery, University Hospitals Leuven,
Leuven, Belgium
- Department of Imaging and Pathology, OMFS IMPATH Research Group, Faculty of
Medicine, KU Leuven, Leuven, Belgium
| | - Constantinus Politis
- Department of Oral and Maxillofacial Surgery, University Hospitals Leuven,
Leuven, Belgium
- Department of Imaging and Pathology, OMFS IMPATH Research Group, Faculty of
Medicine, KU Leuven, Leuven, Belgium
| |
Collapse
|