1
|
Coughlan MF, Sawhney MS, Pleskow DK, Khan U, Silva-Santisteban A, Ahmed A, Zhang X, Glyavina M, Chen L, Upputuri PK, Zakharov YN, Zhang L, Qiu L, Perelman LT. Biopsy channel of the endoscope as a potential source of infectious droplets during GI endoscopy. Gastrointest Endosc 2022; 96:764-770. [PMID: 35724696 PMCID: PMC10699089 DOI: 10.1016/j.gie.2022.06.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 05/11/2022] [Accepted: 06/08/2022] [Indexed: 02/08/2023]
Abstract
BACKGROUND AND AIMS During endoscopy, droplets with the potential to transmit infectious diseases are known to emanate from a patient's mouth and anus, but they may also be expelled from the biopsy channel of the endoscope. The main goal of our study was to quantify droplets emerging from the biopsy channel during clinical endoscopy. METHODS A novel light-scattering device was used to measure droplets emanating from the biopsy channel. An endoscopy model was created, and in vitro measurements were carried out during air insufflation, air and water suctioning, and the performance of biopsy sampling. Similar measurements were then made on patients undergoing endoscopy, with all measurements taking place over 2 days to minimize variation. RESULTS During in vitro testing, no droplets were observed at the biopsy channel during air insufflation or air and water suctioning. In 3 of 5 cases, droplets were observed during biopsy sampling, mostly when the forceps were being removed from the endoscope. In the 22 patients undergoing routine endoscopy, no droplets were observed during air insufflation and water suctioning. Droplets were detected in 1 of 11 patients during air suctioning. In 9 of 18 patients undergoing biopsy sampling and 5 of 6 patients undergoing snare polypectomies, droplets were observed at the biopsy channel, mostly when instruments were being removed from the endoscope. CONCLUSIONS We found that the biopsy channel may be a source of infectious droplets, especially during the removal of instruments from the biopsy channel. When compared with droplets reported from the mouth and anus, these droplets were larger in size and therefore potentially more infectious.
Collapse
Affiliation(s)
- Mark F. Coughlan
- Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School
| | - Mandeep S. Sawhney
- Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School
| | - Douglas K. Pleskow
- Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School
| | - Umar Khan
- Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School
| | - Andy Silva-Santisteban
- Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School
| | - Awais Ahmed
- Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School
| | - Xuejun Zhang
- Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School
| | - Maria Glyavina
- Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School
| | - Liming Chen
- Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School
| | - Paul K. Upputuri
- Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School
| | - Yuri N. Zakharov
- Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School
| | - Lei Zhang
- Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School
| | - Le Qiu
- Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School
| | - Lev T. Perelman
- Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School
- Biological and Biomedical Sciences Program, Harvard University
| |
Collapse
|
2
|
Nampoolsuksan C, Chinswangwatanakul V, Methasate A, Swangsri J, Trakarnsanga A, Phalanusitthepha C, Parakonthun T, Taweerutchana V, Srisuworanan N, Suwatthanarak T, Tawantanakorn T, Akaraviputh T. Management of aerosol generation during upper gastrointestinal endoscopy. Clin Endosc 2022; 55:588-593. [PMID: 35999697 PMCID: PMC9539303 DOI: 10.5946/ce.2022.062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Accepted: 03/07/2022] [Indexed: 11/17/2022] Open
Abstract
In the highly contagious coronavirus disease 2019 pandemic, aerosol-generating procedures (AGPs) are associated with high-risk of transmission. Upper gastrointestinal endoscopy is a procedure with the potential to cause dissemination of bodily fluids. At present, there is no consensus that endoscopy is defined as an AGP. This review discusses the current evidence on this topic with additional management. Prevailing publications on coronavirus related to upper gastrointestinal endoscopy and aerosolization from the PubMed and Scopus databases were searched and reviewed. Comparative quantitative analyses showed a significant elevation of particle numbers, implying that aerosols were generated by upper gastrointestinal endoscopy. The associated source events have also been reported. To reduce the dispersion, certain protective measures have been developed. Endoscopic unit protocols are recommended for the concerned personnel. Therefore, upper gastrointestinal endoscopy should be classified as an AGP. Proper practices should be adopted by healthcare workers and patients.
Collapse
Affiliation(s)
- Chawisa Nampoolsuksan
- Department of Surgery, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | | | - Asada Methasate
- Department of Surgery, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Jirawat Swangsri
- Department of Surgery, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Atthaphorn Trakarnsanga
- Department of Surgery, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | | | - Thammawat Parakonthun
- Department of Surgery, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Voraboot Taweerutchana
- Department of Surgery, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Nicha Srisuworanan
- Department of Surgery, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Tharathorn Suwatthanarak
- Department of Surgery, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | | | - Thawatchai Akaraviputh
- Department of Surgery, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| |
Collapse
|
3
|
Kosasih S, Metussin A, Basir N, Chong VH. Simple and innovative methods of minimizing risk of aerosol generation during endoscopy. Clin Endosc 2022; 55:470-472. [PMID: 35656630 PMCID: PMC9178149 DOI: 10.5946/ce.2022.069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2022] [Accepted: 03/05/2022] [Indexed: 11/17/2022] Open
Affiliation(s)
- Sumitro Kosasih
- Gastroenterology & Hepatology Unit, Department of Internal Medicine, Raja Isteri Pengiran Anak Saleha Hospital, Bandar Seri Begawan, Brunei Darussalam
| | - Adli Metussin
- Gastroenterology & Hepatology Unit, Department of Internal Medicine, Raja Isteri Pengiran Anak Saleha Hospital, Bandar Seri Begawan, Brunei Darussalam
| | - Norwani Basir
- Gastroenterology & Hepatology Unit, Department of Internal Medicine, Raja Isteri Pengiran Anak Saleha Hospital, Bandar Seri Begawan, Brunei Darussalam
| | - Vui Heng Chong
- Gastroenterology & Hepatology Unit, Department of Internal Medicine, Raja Isteri Pengiran Anak Saleha Hospital, Bandar Seri Begawan, Brunei Darussalam
- Correspondence: Vui Heng Chong Gastroenterology & Hepatology Unit, Department of Internal Medicine, Raja Isteri Pengiran Anak Saleha Hospital, Jalan Putera Al-Muhtadee Billah, Bandar Seri Begawan BA1712, Brunei Darussalam E-mail:
| |
Collapse
|
4
|
Cho SJ. A Novel Aerosol-Exposure Protection Mask for Patients During Upper Endoscopy. Clin Endosc 2022; 55:208-209. [PMID: 35391520 PMCID: PMC8995990 DOI: 10.5946/ce.2022.064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Accepted: 03/03/2022] [Indexed: 11/24/2022] Open
Affiliation(s)
- Soo-Jeong Cho
- Department of Internal Medicine and Liver Research Institute, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
- Correspondence: Soo-Jeong Cho Division of Gastroenterology, Department of Internal Medicine and Liver Research Institute, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul 03080, Korea Tel: +82-2-2072-4073, Fax: +82-2-762-9662, E-mail: ,
| |
Collapse
|