1
|
Safahieh AH, Nazemi H, Arjmand N, Azimi P, Khalaf K. Design, fabrication, and evaluation of single- and multi-level 3D-printed non-covering cervical spinal fusion surgery templates. Front Bioeng Biotechnol 2024; 12:1416872. [PMID: 39070162 PMCID: PMC11272535 DOI: 10.3389/fbioe.2024.1416872] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2024] [Accepted: 06/17/2024] [Indexed: 07/30/2024] Open
Abstract
Background Cervical spinal fusion surgeries require accurate placement of the pedicle screws. Any misplacement/misalignment of these screws may lead to injuries to the spinal cord, arteries and other organs. Template guides have emerged as accurate and cost-effective tools for the safe and rapid insertions of pedicle screws. Questions/Purposes Novel patient-specific single- and multi-level non-covering templates for cervical pedicle screw insertions were designed, 3D-printed, and evaluated. Methods CT scans of two patients were acquired to reconstruct their 3D spine model. Two sets of single-level (C3-C7) and multi-level (C4-C6) templates were designed and 3D-printed. Pedicle screws were inserted into the 3D-printed vertebrae by free-hand and guided techniques. For single-level templates, a total of 40 screws (2 patients × 5 vertebrae × 2 methods × 2 screws) and for multi-level templates 24 screws (2 patients × 3 vertebrae × 2 methods × 2 screws) were inserted by an experienced surgeon. Postoperative CT images were acquired to measure the errors of the entry point, 3D angle, as well as axial and sagittal plane angles of the inserted screws as compared to the initial pre-surgery designs. Accuracy of free-hand and guided screw insertions, as well as those of the single- and multi-level guides, were also compared using paired t-tests. Results Despite the minimal removal of soft tissues, the 3D-printed templates had acceptable stability on the vertebrae during drillings and their utilization led to statistically significant reductions in all error variables. The mean error of entry point decreased from 3.02 mm (free-hand) to 0.29 mm (guided) using the single-level templates and from 5.7 mm to 0.76 mm using the multi-level templates. The percentage reduction in mean of other error variables for, respectively, single- and multi-level templates were as follows: axial plane angle: 72% and 87%, sagittal plane angle: 56% and 78%, and 3D angle: 67% and 83%. The error variables for the multi-level templates generally exceeded those of the single-level templates. The use of single- and multi-level templates also considerably reduced the duration of pedicle screw placements. Conclusion The novel single- and multi-level non-covering templates are valuable tools for the accurate placement of cervical pedicle screws.
Collapse
Affiliation(s)
- A. H. Safahieh
- Mechanical Engineering Department, Sharif University of Technology, Tehran, Iran
| | - H. Nazemi
- Mechanical Engineering Department, Sharif University of Technology, Tehran, Iran
| | - N. Arjmand
- Mechanical Engineering Department, Sharif University of Technology, Tehran, Iran
| | - P. Azimi
- Neuroscience Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - K. Khalaf
- Department of Biomedical Engineering and Health Engineering Innovation Center, Khalifa University of Science and Technology, Abu Dhabi, United Arab Emirates
| |
Collapse
|
2
|
Zhang Y, Guo Y, Li Z, Wang B, Li Z. 3D-printed Multifunctional Guide Plate for Fenestration and Screws Drill in Proximal Femoral Benign Tumor. Orthop Surg 2024; 16:1487-1492. [PMID: 38726583 PMCID: PMC11144502 DOI: 10.1111/os.14075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Revised: 04/06/2024] [Accepted: 04/07/2024] [Indexed: 06/04/2024] Open
Abstract
The accurate fenestration, screw implantation and assisting stabilizing-plate placement in surgery of benign tumors in the proximal femur needs be defined easily. The aim of this study was to investigate the value of 3D printed multifunctional guides plate (3D-MGP) based on computer aided design. Between January 2020 and June 2022, 17 patients (nine females and eight males) with benign proximal femoral tumor had lesion curettage and allograft combined with internal plate fixation using 3D-MGP. In this study, the patients had CT scans and a technician reconstructed the 3D images of tumor and the femur, a doctor designed the location and margin of the fenestration and screws, and integrated different functions into MGP for benign proximal femoral lesions, which assisted in precise localization, fenestration and screw drilling. Musculoskeletal Tumor Society (MSTS) scoring was used to evaluate lower extremity function. Bone healing and the screws location was assessed with the radiographs. All patients underwent successful surgery with complete resection of the tumor and internal fixation with using the 3D-MGP. The mean follow-up was 16.4 months. The operative time was 126.47 ± 18.44 min, intraoperative bleeding was 198.23 ± 67.94 mL, intraoperative fluoroscopy was 6.47 ± 0.62, postoperative drainage was 223.82 ± 119.51 mL, and MSTS score was 27.29 ± 1.31 points. There were no unplanned fenestration and improper screw fixation. The 3D-MGP enabled personalized and accurate location of tumor, fenestration, screw placement and assisted stabilizing-plate placement for the treatment of benign tumor of the proximal femur. This technique has the potential to shorten operative times, decrease intraoperative bleeding, and reduce radiation exposure to patients.
Collapse
Affiliation(s)
- Yuxuan Zhang
- Department of OrthopedicsQilu Hospital of Shandong UniversityJinanChina
| | - Yi Guo
- Montefiore Medical CenterAlbert Einstein School of MedicineNew YorkNew YorkUSA
| | - Zonghao Li
- Department of OrthopedicsQilu Hospital of Shandong UniversityJinanChina
| | - Bing Wang
- School of Mechanical EngineeringShandong UniversityJinanChina
| | - Zhenfeng Li
- Department of OrthopedicsQilu Hospital of Shandong UniversityJinanChina
| |
Collapse
|
3
|
Malikov A, Secen AE, Ocal O, Divanlioglu D, Belen AD, Dalgic A. Accuracy of Axis Drill Guides in the Cases of Atlantoaxial Instabilities Associated With High-Riding Vertebral Arteries, Narrow Pedicles, and Complex Deformities: Comparison of 3 Fixation Methods. World Neurosurg 2022; 168:e336-e343. [DOI: 10.1016/j.wneu.2022.10.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2022] [Accepted: 10/03/2022] [Indexed: 12/15/2022]
|
4
|
Clinical applications and prospects of 3D printing guide templates in orthopaedics. J Orthop Translat 2022; 34:22-41. [PMID: 35615638 PMCID: PMC9117878 DOI: 10.1016/j.jot.2022.03.001] [Citation(s) in RCA: 24] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/14/2022] [Revised: 02/27/2022] [Accepted: 03/01/2022] [Indexed: 12/05/2022] Open
Abstract
Background With increasing requirements for medical effects, and huge differences among individuals, traditional surgical instruments are difficult to meet the patients' growing medical demands. 3D printing is increasingly mature, which connects to medical services critically as well. The patient specific surgical guide plate provides the condition for precision medicine in orthopaedics. Methods In this paper, a systematic review of the orthopedic guide template is presented, where the history of 3D-printing-guided technology, the process of guides, and basic clinical applications of orthopedic guide templates are described. Finally, the limitations of the template and possible future directions are discussed. Results The technology of 3D printing surgical templates is increasingly mature, standard, and intelligent. With the help of guide templates, the surgeon can easily determine the direction and depth of the screw path, and choose the angle and range of osteotomy, increasing the precision, safety, and reliability of the procedure in various types of surgeries. It simplifies the difficult surgical steps and accelerates the growth of young and mid-career physicians. But some problems such as cost, materials, and equipment limit its development. Conclusions In different fields of orthopedics, the use of guide templates can significantly improve surgical accuracy, shorten the surgical time, and reduce intraoperative bleeding and radiation. With the development of 3D printing, the guide template will be standardized and simplified from design to production and use. 3D printing guides will be further sublimated in the application of orthopedics and better serve the patients. The translational potential of this paper Precision, intelligence, and individuation are the future development direction of orthopedics. It is more and more popular as the price of printers falls and materials are developed. In addition, the technology of meta-universe, digital twin, and artificial intelligence have made revolutionary effects on template guides. We aim to summarize recent developments and applications of 3D printing guide templates for engineers and surgeons to develop more accurate and efficient templates.
Collapse
|
5
|
Wu C, Deng J, Zeng B, Zhu YF, Li T. Three-dimensional anatomic analysis and navigation templates for C1 pedicle screw placement perpendicular to the coronal plane: a retrospective study. Neurol Res 2021; 43:961-969. [PMID: 34227928 DOI: 10.1080/01616412.2021.1948741] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
OBJECTIVE To explore the corridor for atlas pedicle screw placement perpendicular to the coronal plane and to develop patient-specific navigation templates for pedicle screw placement. METHODS This study is a retrospective analysis. A total of 71 patients (41 males and 30 females) were involved in this study from June 2016 to June 2018, and they were divided into a template group (39 patients) and a conventional group (32 patients). The CT-based 3D reconstruction models were analyzed in the template group. From the perspective of the 3D atlas in a coronal view, the pedicle corridor was obtained. Taking the center of the tangential circle of the pedicle as the entry point, we simulated screw placement perpendicular to the coronal plane. Then, the individual navigation template was designed and used in surgery. In the conventional group, free-hand pedicle screw placement was performed perpendicular to the coronal plane. The diameter of the maximum tangential circle and screw length of the pedicle corridor were measured in the template group. The surgical time, radiation exposure time, screw grading criteria and so on were evaluated and compared between the two groups after surgery. RESULTS ;The diameter of the maximum tangential circle and the distance between the entry point and posterior tubercle were significantly greater in males than in females. The operation was successfully completed in all patients, without aggravation of nerve injury, and the follow-up was 12-20 months, with an average of 15.6 months. A total of 78 screws were inserted in the template group, and 64 screws were inserted in the conventional group. The surgical times in the template group and conventional group were 76.47±24.44 min and 125.63±36.41 min, respectively. The radiation exposure times in the template group and conventional group were 3.51±1.77 and 10.15±4.95, respectively, and there was a significant difference between the two groups. In the template group, the deviation in the screw entry point and screw angle were 1.92±1.67 mm and 2.08±1.98°, respectively. The medial angle deviation between the left and right sides was 2.71±1.88° in the template group, which was significantly less than the deviation of 3.76±2.22° in the conventional group. CONCLUSION A pedicle screw trajectory perpendicular to the coronal plane can be quickly obtained based on the perspective of 3D models. The technique of screw placement perpendicular to the coronal plane assisted by navigation templates has a shorter operative time, lessintraoperative fluoroscopy and a higher safety of screw placement than traditional surgery.
Collapse
Affiliation(s)
- Chao Wu
- Orthopedics Center of Zigong Fourth People's Hospital, Zigong, China.,Digital Medical Center of Zigong Fourth People's Hospital, Zigong,China
| | - Jiayan Deng
- Digital Medical Center of Zigong Fourth People's Hospital, Zigong,China
| | - Bofang Zeng
- Orthopedics Center of Zigong Fourth People's Hospital, Zigong, China
| | - Yuan Fang Zhu
- Health Management Center of Zigong Fourth People's Hospital, Zigong, China
| | - Tao Li
- Orthopedics Center of Zigong Fourth People's Hospital, Zigong, China
| |
Collapse
|
6
|
3D-printed navigation template in cervical spine fusion: a systematic review and meta-analysis. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2020; 30:389-401. [DOI: 10.1007/s00586-020-06601-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2020] [Revised: 06/28/2020] [Accepted: 09/05/2020] [Indexed: 12/19/2022]
|
7
|
Azimi P, Yazdanian T, Benzel EC, Aghaei HN, Azhari S, Sadeghi S, Montazeri A. Accuracy and safety of C2 pedicle or pars screw placement: a systematic review and meta-analysis. J Orthop Surg Res 2020; 15:272. [PMID: 32690035 PMCID: PMC7372824 DOI: 10.1186/s13018-020-01798-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Accepted: 07/14/2020] [Indexed: 11/25/2022] Open
Abstract
Study design Systematic review and meta-analysis. Aim The purpose of this study was to compare the safety and accuracy of the C2 pedicle versus C2 pars screws placement and free-hand technique versus navigation for upper cervical fusion patients. Methods Databases searched included PubMed, Scopus, Web of Science, and Cochrane Library to identify all papers published up to April 2020 that have evaluated C2 pedicle/pars screws placement accuracy. Two authors individually screened the literature according to the inclusion and exclusion criteria. The accuracy rates associated with C2 pedicle/pars were extracted. The pooled accuracy rate estimated was performed by the CMA software. A funnel plot based on accuracy rate estimate was used to evaluate publication bias. Results From 1123 potentially relevant studies, 142 full-text publications were screened. We analyzed data from 79 studies involving 4431 patients with 6026 C2 pedicle or pars screw placement. We used the Newcastle-Ottawa Scale (NOS) to evaluate the quality of studies included in this review. Overall, funnel plot and Begg’s test did not indicate obvious publication bias. The pooled analysis reveals that the accuracy rates were 93.8% for C2 pedicle screw free-hand, 93.7% for pars screw free-hand, 92.2% for navigated C2 pedicle screw, and 86.2% for navigated C2 pars screw (all, P value < 0.001). No statistically significant differences were observed between the accuracy of placement C2 pedicle versus C2 pars screws with the free-hand technique and the free-hand C2 pedicle group versus the navigated C2 pedicle group (all, P value > 0.05). Conclusion Overall, there was no difference in the safety and accuracy between the free-hand and navigated techniques. Further well-conducted studies with detailed stratification are needed to complement our findings.
Collapse
Affiliation(s)
- Parisa Azimi
- Department of Neurosurgery, Shahid Beheshti University of Medical Sciences, Arabi Ave, Daneshjoo Blvd, Velenjak, Tehran, 19839-63113, Iran.
| | | | - Edward C Benzel
- Department of Neurosurgery, Cleveland Clinic Foundation, Cleveland, OH, USA
| | - Hossein Nayeb Aghaei
- Department of Neurosurgery, Shahid Beheshti University of Medical Sciences, Arabi Ave, Daneshjoo Blvd, Velenjak, Tehran, 19839-63113, Iran
| | - Shirzad Azhari
- Department of Neurosurgery, Shahid Beheshti University of Medical Sciences, Arabi Ave, Daneshjoo Blvd, Velenjak, Tehran, 19839-63113, Iran
| | - Sohrab Sadeghi
- Department of Neurosurgery, Shahid Beheshti University of Medical Sciences, Arabi Ave, Daneshjoo Blvd, Velenjak, Tehran, 19839-63113, Iran
| | - Ali Montazeri
- Population Health Research Group, Mental Health Research Group, Health Metrics Research Centre, Iranian Institute for Health Sciences Research, ACECR, Tehran, Iran
| |
Collapse
|
8
|
Feng S, Lin J, Su N, Meng H, Yang Y, Fei Q. 3-Dimensional printing templates guiding versus free hand technique for cervical lateral mass screw fixation: A prospective study. J Clin Neurosci 2020; 78:252-258. [PMID: 32340846 DOI: 10.1016/j.jocn.2020.04.008] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2020] [Accepted: 04/05/2020] [Indexed: 11/19/2022]
Abstract
OBJECTIVE In this randomized, single blind and controlled study, the feasibility and precision of 3-dimensional printing templates for cervical lateral mass screw insertion was evaluated. METHODS A total of 6 patients (72 screws), who were diagnosed with cervical spondylotic myelopathy (CSM) and developmental cervical spinal stenosis, were randomly divided into A and B two groups. All subjects underwent modified posterior surgery with using cervical lateral mass screws insertion (C4-C6). Group A underwent surgeries with screw insertion assisted by the guidance of 3-dimensional printing templates and Group B underwent surgeries with screw insertion by freehand. The criteria of the accuracy of screw placement were set as the main evaluation indicators. RESULTS There was no significant difference between the 2 groups in age, improvement rate of JOA, operation time and blood loss. According to Bayard's criteria, 32 screws (88.9%) were described as "acceptable" in group A and 22 screws (61.1%) were described as "acceptable" in Group B (P < 0.05). Based on our criteria, the "excellent and good" rate of screws was 83.3% in group A and 47.2% in Group B, respectively (P < 0.05). The precision of screws' location in Group A was superior to that in Group B. CONCLUSIONS 3-Dimensional printing screw insertion templates may achieve (1) comprehensive visualization of the cervical vertebrae and lateral mass and the individual surgical planning using the 3-dimensional model preoperatively. (2) increasing the accuracy of cervical lateral mass screw insertion.
Collapse
Affiliation(s)
- Shitong Feng
- Department of Orthopaedics, Beijing Friendship Hospital, Capital Medical University, 100050, China
| | - Jisheng Lin
- Department of Orthopaedics, Beijing Friendship Hospital, Capital Medical University, 100050, China
| | - Nan Su
- Department of Orthopaedics, Beijing Friendship Hospital, Capital Medical University, 100050, China
| | - Hai Meng
- Department of Orthopaedics, Beijing Friendship Hospital, Capital Medical University, 100050, China
| | - Yong Yang
- Department of Orthopaedics, Beijing Friendship Hospital, Capital Medical University, 100050, China.
| | - Qi Fei
- Department of Orthopaedics, Beijing Friendship Hospital, Capital Medical University, 100050, China.
| |
Collapse
|
9
|
Zhang M, Li J, Fang T, Zhao J, Pan W, Wang X, Xu J, Zhou Q. Evaluation of a Three-Dimensional Printed Guide and a Polyoxymethylene Thermoplastic Regulator for Percutaneous Pedicle Screw Fixation in Patients with Thoracolumbar Fracture. Med Sci Monit 2020; 26:e920578. [PMID: 31932574 PMCID: PMC6982400 DOI: 10.12659/msm.920578] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
BACKGROUND This study aimed to evaluate the efficacy of a porous polyoxymethylene thermoplastic regulator combined with a three-dimensional (3D) printed template to guide pedicle needle insertion in patients undergoing percutaneous pedicle screw fixation (PPSF) for thoracolumbar fracture. MATERIAL AND METHODS Forty patients were randomly divided into group A, treated using a porous polyoxymethylene thermoplastic regulator combined with a 3D printed template, and group B, who underwent conventional PPSF. Data recorded included the number of pedicle screws successfully inserted on the first attempt, the number of attempts, the time to successful needle insertion, the total time of fluoroscopy, and the duration of surgery. The Visual Analogue Scale (VAS) and the Oswestry Disability Index (ODI) scores one day before surgery, and at day 1, day 7, month 1, and month 3 after surgery were recorded. The postoperative vertebral posterior kyphotic angle (KA) and the rate of change of KA were recorded. RESULTS Group A had a significantly increased total number of successful first insertions compared with group BV (P<0.05). Postoperative VAS and ODI scores of patients in both groups were significantly lower than before surgery (P<0.05), with no significant difference between the two groups at postoperative month 1 and month 3 (P>0.05). The postoperative vertebral posterior KA decreased significantly in both groups after surgery, with no significant difference between the two groups (P>0.05). CONCLUSIONS The use of a porous polyoxymethylene thermoplastic regulator combined with a 3D printed template may improve the success of pedicle insertion in patients undergoing PPSF.
Collapse
Affiliation(s)
- Ming Zhang
- Department of Orthopedic Surgery, The Second Peoples' Hospital of Huai'an, Xuzhou Medical University, Huai'an, Jiangsu, China (mainland)
| | - Jiayi Li
- Department of Orthopedic Surgery, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu, China (mainland)
| | - Tao Fang
- Department of Orthopedic Surgery, The Second Peoples' Hospital of Huai'an, Xuzhou Medical University, Huai'an, Jiangsu, China (mainland)
| | - Jiali Zhao
- Department of Orthopedic Surgery, The Second Peoples' Hospital of Huai'an, Xuzhou Medical University, Huai'an, Jiangsu, China (mainland)
| | - Wei Pan
- Department of Orthopedic Surgery, The Second Peoples' Hospital of Huai'an, Xuzhou Medical University, Huai'an, Jiangsu, China (mainland)
| | - Xinhong Wang
- Department of Orthopedic Surgery, The Second Peoples' Hospital of Huai'an, Xuzhou Medical University, Huai'an, Jiangsu, China (mainland)
| | - Jin Xu
- Department of Orthopedic Surgery, The Second Peoples' Hospital of Huai'an, Xuzhou Medical University, Huai'an, Jiangsu, China (mainland)
| | - Quan Zhou
- Department of Orthopedic Surgery, The Second Peoples' Hospital of Huai'an, Xuzhou Medical University, Huai'an, Jiangsu, China (mainland)
| |
Collapse
|