1
|
Pumar JM, Sucasas P, Mosqueira A, Vega P, Murias E. Five-Years Angiographic Follow-Up of Wide-Neck Intracranial Aneurysms Treated With LEO Plus Stent. Front Neurol 2021; 12:744962. [PMID: 34899568 PMCID: PMC8661051 DOI: 10.3389/fneur.2021.744962] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Accepted: 10/22/2021] [Indexed: 11/25/2022] Open
Abstract
Background: This study aimed to evaluate the angiographic and clinical outcome, with an emphasis on long-term follow-up, of the LEO Plus stent for wide-neck intracranial aneurysms treated in a single center. Methods: We retrospectively examined a prospectively maintained database of patients treated with LEO Plus devices between January 2004 and December 2016. Data regarding patient demographics, aneurysm characteristics, and technical procedures were analyzed. Angiographic and clinical findings were recorded during the procedure and followed up over a period of at least 5 years. Results: We identified 101 patients with 116 aneurysms. In 16 patients, the stent could not safely be placed. Thus, a total of 97 LEO Plus devices were implanted in 97 aneurysms of 85 patients. Adverse events (acute and delayed) were observed in 21.6% of cases (17/85), and most were resolved (70.6%; 12/17). Moreover, 5 years after the procedure, total morbidity and mortality were 2.3% (2/85) and 3.5% (3/85), respectively. Long-term imaging follow-up showed complete occlusions, neck remnants, and residual aneurysms in 73.1% (57/78), 14.1% (11/78), and 12.8% (10/78) of cases, respectively. Conclusions: Long-term results of treatment of brain aneurysms with LEO stent show high rates of adequate and stable occlusion over time, with acceptable morbidity and mortality.
Collapse
Affiliation(s)
- José M Pumar
- Catedra de Neurorradiología Intervencionista, Universidad de Santiago de Compostela, Santiago de Compostela, Spain.,Neuroradiology Department, Hospital Clínico Universitario, Santiago de Compostela, Spain
| | - Paula Sucasas
- Catedra de Neurorradiología Intervencionista, Universidad de Santiago de Compostela, Santiago de Compostela, Spain.,Neuroradiology Department, Hospital Clínico Universitario, Santiago de Compostela, Spain
| | - Antonio Mosqueira
- Catedra de Neurorradiología Intervencionista, Universidad de Santiago de Compostela, Santiago de Compostela, Spain.,Neuroradiology Department, Hospital Clínico Universitario, Santiago de Compostela, Spain
| | - Pedro Vega
- Catedra de Neurorradiología Intervencionista, Universidad de Santiago de Compostela, Santiago de Compostela, Spain.,Neuroradiology Department, Hospital Clínico Universitario de Oviedo, Oviedo, Spain
| | - Eduardo Murias
- Catedra de Neurorradiología Intervencionista, Universidad de Santiago de Compostela, Santiago de Compostela, Spain.,Neuroradiology Department, Hospital Clínico Universitario de Oviedo, Oviedo, Spain
| |
Collapse
|
2
|
Chen L, Zheng C, Wu J, Gong J, Gao Y, Wan S. The Enterprise2 Stent for Endovascular Treatment of Intracranial Aneurysms: Short-Term Results From a Single Center Experience. Front Neurol 2020; 11:589689. [PMID: 33343493 PMCID: PMC7744753 DOI: 10.3389/fneur.2020.589689] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Accepted: 11/03/2020] [Indexed: 11/13/2022] Open
Abstract
Background: Self-expanding devices, such as the Enterprise VRD (EP-VRD) have widely used for stent-assisted coiling treatment in wided-necked aneuryms while some thromboembolic complications were reported due to its incomplete stent apposition (ISA). We report our experiences on the novel Enterprise2 (EP-VRD2) stent in vivo in the treatment of intracranial and cranial cervical junction aneurysms. Methods: Twenty-five consecutive patients with intracranial or cranial cervical junction aneurysms were treated with EP-VRD2 stents retrospectively collected in our institution. We use the ‘jailing' technique in all cases and deployed the stent by using pushing over the outer curve technique. The 3- or 6-monthS follow-up was done regularly by DSA. Results: Twenty-five EP-VRD2 stents were implanted to treat 21 aneurysms at the siphon segment of internal carotid artery (ICA), one at the petrous segment, two at the cervical segment, one at the verteral artery with five accompanied with stenosis. Two patients had kinking during the procedure and were solved by microwire or microcatheter massaging. Four patients with a larger arc angle and a smaller radius of the parent vessel was detected ISA. No patient underwent the ischemic event after the operation. Twenty-three of 25 patients were evaluated after 3- or 6-months by DSA, 22 showed complete occlusion (RROC1), one slight re-stenosis in the follow-up within those five patients with stenosis. A length of 23 mm seemed associated with ISA (p < 0.01). Conclusion: The EP-VRD2 performed well in our small patient series; however, ISA could still occur with a sharp angle of the parent vessel.
Collapse
Affiliation(s)
- Linhui Chen
- Brain Center Department, Zhejiang Hospital, Hangzhou, China
| | - Chaobo Zheng
- Brain Center Department, Zhejiang Hospital, Hangzhou, China
| | - Jiong Wu
- Brain Center Department, Zhejiang Hospital, Hangzhou, China
| | - Jie Gong
- Brain Center Department, Zhejiang Hospital, Hangzhou, China
| | - Yuhai Gao
- Brain Center Department, Zhejiang Hospital, Hangzhou, China
| | - Shu Wan
- Brain Center Department, Zhejiang Hospital, Hangzhou, China
| |
Collapse
|
3
|
Zhu Y, Zhang H, Zhang Y, Wu H, Wei L, Zhou G, Zhang Y, Deng L, Cheng Y, Li M, Santos HA, Cui W. Endovascular Metal Devices for the Treatment of Cerebrovascular Diseases. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2019; 31:e1805452. [PMID: 30589125 DOI: 10.1002/adma.201805452] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/21/2018] [Revised: 09/20/2018] [Indexed: 06/09/2023]
Abstract
Cerebrovascular disease involves various medical disorders that obstruct brain blood vessels or deteriorate cerebral circulation, resulting in ischemic or hemorrhagic stroke. Nowadays, platinum coils with or without biological modification have become routine embolization devices to reduce the risk of cerebral aneurysm bleeding. Additionally, many intracranial stents, flow diverters, and stent retrievers have been invented with uniquely designed structures. To accelerate the translation of these devices into clinical usage, an in-depth understanding of the mechanical and material performance of these metal-based devices is critical. However, considering the more distal location and tortuous anatomic characteristics of cerebral arteries, present devices still risk failing to arrive at target lesions. Consequently, more flexible endovascular devices and novel designs are under urgent demand to overcome the deficiencies of existing devices. Herein, the pros and cons of the current structural designs are discussed when these devices are applied to the treatment of diseases ranging broadly from hemorrhages to ischemic strokes, in order to encourage further development of such kind of devices and investigation of their use in the clinic. Moreover, novel biodegradable materials and drug elution techniques, and the design, safety, and efficacy of personalized devices for further clinical applications in cerebral vasculature are discussed.
Collapse
Affiliation(s)
- Yueqi Zhu
- Department of Radiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yishan Road, Shanghai, 200233, P. R. China
| | - Hongbo Zhang
- Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, P. R. China
- Department of Pharmaceutical Sciences Laboratory, Åbo Akademi University, Turku, FI-20520, Finland
- Turku Center for Biotechnology, University of Turku and Åbo Akademi University, Turku, FI-20520, Finland
| | - Yiran Zhang
- Department of Radiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yishan Road, Shanghai, 200233, P. R. China
| | - Huayin Wu
- Harvard John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, 02138, USA
| | - Liming Wei
- Department of Radiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yishan Road, Shanghai, 200233, P. R. China
| | - Gen Zhou
- Department of Radiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yishan Road, Shanghai, 200233, P. R. China
| | - Yuezhou Zhang
- Department of Pharmaceutical Sciences Laboratory, Åbo Akademi University, Turku, FI-20520, Finland
- Turku Center for Biotechnology, University of Turku and Åbo Akademi University, Turku, FI-20520, Finland
| | - Lianfu Deng
- Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, P. R. China
| | - Yingsheng Cheng
- Department of Radiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yishan Road, Shanghai, 200233, P. R. China
| | - Minghua Li
- Department of Radiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yishan Road, Shanghai, 200233, P. R. China
| | - Hélder A Santos
- Drug Research Program, Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, University of Helsinki, FI-00014, Helsinki, Finland
- Helsinki Institute of Life Science, University of Helsinki, FI-00014, Helsinki, Finland
| | - Wenguo Cui
- Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, P. R. China
| |
Collapse
|
4
|
Heo HY, Ahn JG, Ji C, Yoon WK. Selective Temporary Stent-Assisted Coil Embolization for Intracranial Wide-Necked Small Aneurysms Using Solitaire AB Retrievable Stent. J Korean Neurosurg Soc 2019; 62:27-34. [PMID: 30630293 PMCID: PMC6328798 DOI: 10.3340/jkns.2018.0064] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2018] [Accepted: 10/12/2018] [Indexed: 12/02/2022] Open
Abstract
Objective Stent-assisted coil embolization of intracranial wide-necked aneurysm requires long-term postoperative antiplatelet therapy to prevent in-stent thrombosis. This study aimed to demonstrate results of temporary stent placement for coiling wide necked small intracranial aneurysms, which eliminated need for antiplatelet agents, and to discuss its feasibility and safety.
Methods Data of 156 patients who underwent stent-assisted coil embolization between 2011 and 2014 were retrospectively analyzed. Thirteen cases of temporary stent-assisted coil embolization were included, and their clinical and radiological results were evaluated.
Results The aneurysms treated were all unruptured except one case. All of them had wide neck with mean dome-to-neck ratio of 0.96 and were small-sized aneurysms with mean maximal diameter of 4.2 mm. There was no technical failure in retrieval of stent after completion of embolization of the target aneurysm. Immediate angiography revealed 11 complete and two partial embolization (one residual neck and one residual aneurysm). Two cases encountered thrombosis complication, and they were managed without neurological sequelae. The mean follow-up period was 43 months, angiographic follow-up revealed two cases with minor recurrence, and clinical outcome was good with modified Rankin scale score of 0.
Conclusion Temporary stent-assisted coil embolization of small wide-necked intracranial aneurysm using fully retrievable stent appears safe and effective. Further application and evaluation of this technique in more cases with larger size aneurysm is warranted.
Collapse
Affiliation(s)
- Han Yong Heo
- Department of Neurosurgery, St. Paul's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Jae Guen Ahn
- Department of Neurosurgery, St. Paul's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Cheol Ji
- Department of Neurosurgery, St. Paul's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Won Ki Yoon
- Department of Neurosurgery, Korea University Guro Hospital, Korea University College of Medicine, Seoul, Korea
| |
Collapse
|
5
|
Corliss BM, Barkley KF, Polifka AJ, Hoh BL, Fox WC. Single-Center Case Series of Temporary Stent Assistance for Coiling of Acutely Ruptured Aneurysms. World Neurosurg 2018; 123:e766-e772. [PMID: 30579035 DOI: 10.1016/j.wneu.2018.12.029] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2018] [Revised: 12/03/2018] [Accepted: 12/04/2018] [Indexed: 11/26/2022]
Abstract
BACKGROUND Wide-necked intracranial aneurysms continue to pose a challenge for endovascular surgeons. Flow diversion and stent-assisted coiling are 2 techniques that have improved the ability to manage these lesions, but these require the use of dual antiplatelet therapy. In patients with aneurysmal subarachnoid hemorrhage, dual antiplatelet therapy is relatively contraindicated, and many surgeons prefer to use open techniques or balloon assistance for coiling, although at times the latter is not feasible. We describe temporary stent assistance using retrievable stents for coiling of ruptured intracranial aneurysms as an endovascular management option. METHODS Surgeon case logs were retrospectively reviewed for cases of temporary stent assistance for aneurysm coiling. Cases were identified and compiled into a case series. RESULTS Seven cases were identified, including 6 using the Solitaire FR device in an off-label manner as a temporary stent for assistance with coiling of wide-necked aneurysms. One patient experienced intraoperative aneurysm rupture (planned stent coiling; stent placement aborted after rupture), but otherwise no hemorrhagic complications were noted. Two patients experienced radiographic thromboembolic complications, with 1 patient requiring intervention during the index operation, but neither patient experienced demonstrable neurologic deficits postoperatively. After mean follow-up of 9 months, the average Glasgow Coma Scale score was 14, and the average modified Rankin Scale score was 1.2. CONCLUSIONS Stents and stent retrievers can be temporarily used for technically challenging aneurysms as an alternative to balloon assistance for treatment of ruptured intracranial aneurysms without needing to use dual antiplatelet therapy.
Collapse
Affiliation(s)
- Brian M Corliss
- Department of Neurological Surgery, University of Florida, Gainesville, Florida, USA
| | - Kaitlyn F Barkley
- Department of Neurological Surgery, University of Florida, Gainesville, Florida, USA.
| | - Adam J Polifka
- Department of Neurological Surgery, University of Florida, Gainesville, Florida, USA
| | - Brian L Hoh
- Department of Neurological Surgery, University of Florida, Gainesville, Florida, USA
| | - W Chris Fox
- Department of Neurological Surgery, University of Florida, Gainesville, Florida, USA
| |
Collapse
|
6
|
Nii K, Inoue R, Morinaga Y, Mitsutake T, Hanada H. Evaluation of Acute In-stent Thrombosis during Stent-assisted Coil Embolization of Unruptured Intracranial Aneurysms. Neurol Med Chir (Tokyo) 2018; 58:435-441. [PMID: 30158353 PMCID: PMC6186760 DOI: 10.2176/nmc.oa.2018-0131] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Stent-assisted coil embolization (SACE) is used to address wide-necked or complex aneurysms. However, periprocedural and/or late in-stent thrombosis (IST) elicit neurological events. We investigated the incidence and timed the development of acute IST during SACE with braided- or laser-cut stents in a retrospective study. Between May 2013 and April 2018, we evaluated 11 ISTs that occurred in the course of 185 SACE procedures (self-expandable laser-cut stent, n = 128; braided stent, n = 57). The onset of IST was measured from the time of stent placement. All 11 patients with IST were treated with anticoagulants and underwent hypertension induction. Post-procedural neurological events due to IST were also recorded. The implantation of a laser-cut stent elicited IST in 5 of 128 patients (3.9%); braided stent placements resulted in IST in 6 of 57 patients (10.5%) (P = 0.1). The mean stent diameter was significantly smaller in patients with-IST than without IST (3.0 ± 0.9 mm vs. 4.5 ± 0.7 mm, P = 0.007). The mean interval between stent placement and IST onset was 19 ± 7.7 min; it was significantly earlier for braided- than laser-cut stents (17.5 ± 4.1 min vs. 29.0 ± 4.8 min, P = 0.006). All ISTs were resolved during the procedure. Three patients experienced postoperative neurologic events. We recommend the meticulous and prolonged monitoring of images after stent placement because delayed intraoperative IST can occur especially when laser-cut stents are used.
Collapse
Affiliation(s)
- Kouhei Nii
- Department of Neurosurgery, Fukuoka University Chikushi Hospital
| | - Ritsurou Inoue
- Department of Neurosurgery, Fukuoka University Chikushi Hospital
| | - Yusuke Morinaga
- Department of Neurosurgery, Fukuoka University Chikushi Hospital
| | | | - Hayatsura Hanada
- Department of Neurosurgery, Fukuoka University Chikushi Hospital
| |
Collapse
|
7
|
Sedat J, Chau Y, Gaudart J, Sachet M, Beuil S, Lonjon M. Stent-assisted coiling of intracranial aneurysms using LEO stents: long-term follow-up in 153 patients. Neuroradiology 2017; 60:211-219. [PMID: 29273960 DOI: 10.1007/s00234-017-1965-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2017] [Accepted: 12/15/2017] [Indexed: 01/31/2023]
Abstract
PURPOSE Coiling associated with placement of a self-expandable intracranial stent has improved the treatment of intracranial wide-necked aneurysms. Little is known, however, about the durability of this treatment. The purpose of this report is to present our experience with the LEO stent and to evaluate the complications, effectiveness, and long-term results of this technique. METHODS We analyzed the records of 155 intracranial unruptured aneurysms that were treated by stent-assisted coiling with a LEO stent between 2008 and 2012. Procedural, early post-procedural, and delayed complications were recorded. Clinical and angiographic follow-up of patients was conducted over a period of at least 36 months. RESULTS No procedural mortality was observed. One-month morbidity was observed in 14 out of 153 patients (9,15%). One hundred thirty-eight patients (with 140 aneurysms) had clinical and angiographic follow-up for more than 36 months. No aneurysm rupture was observed during follow-up. Four patients presented an intra-stent stenosis at 8 months, and 6 patients who had an early recurrence were retreated. Final results showed 85% complete occlusion, 13% neck remnants, and 2% stable incomplete occlusion. CONCLUSION Stent-assisted coiling with the LEO stent is a safe and effective treatment for unruptured intracranial aneurysms. The long-term clinical outcomes with the LEO stent are excellent with a high rate of complete occlusion that is stable over time.
Collapse
Affiliation(s)
- Jacques Sedat
- Unité de NeuroInterventionnelle, Hôpital Pasteur 2, 06000, Nice, France.
| | - Yves Chau
- Unité de NeuroInterventionnelle, Hôpital Pasteur 2, 06000, Nice, France
| | - Jean Gaudart
- Aix Marseille University, IRD, INSERM, SESSTIM, Marseille, France
| | - Marina Sachet
- Unité de NeuroInterventionnelle, Hôpital Pasteur 2, 06000, Nice, France
| | | | - Michel Lonjon
- Unité de Neurochirurgie, Hôpital Pasteur 2, Nice, France
| |
Collapse
|
8
|
Shankar JJS, Quateen A, Weill A, Tampieri D, Del Pilar Cortes M, Fahed R, Patro S, Kaderali Z, Lum C, Lesiuk H, Ahmed U, Peeling L, Kelly ME, Iancu D. Canadian Registry of LVIS Jr for Treatment of Intracranial Aneurysms (CaRLA). J Neurointerv Surg 2016; 9:849-853. [PMID: 27543629 DOI: 10.1136/neurintsurg-2016-012611] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2016] [Revised: 07/20/2016] [Accepted: 07/29/2016] [Indexed: 11/04/2022]
Abstract
INTRODUCTION Stents reduce the rate of angiographic recurrence of intracranial aneurysms. The newest stent for intracranial use is the Low-profile Visible Intraluminal Support device (LVIS Jr). OBJECTIVE To assess the efficacy of the new stent in a multicenter retrospective registry. MATERIALS AND METHOD Centers across Canada using LVIS Jr were contacted and asked to participate in a retrospective registry of consecutive patients treated with LVIS Jr for intracranial aneurysms between January 2013 and July 2015. RESULTS A total of 102 patients, with saccular aneurysms in 100 patients (72 women; age range 21-78 years; mean 56.0 years; median 57.5 years) were treated with a LVIS Jr stent. The mean maximum diameter of the dome and neck of the aneurysm and dome to neck ratios were 8.3 mm±7.7 mm, 4.4 mm±1.9 mm, and 1.86±1.22, respectively. Angiographic complications arose in 23 patients, clinical complications in 9 patients, and only 3% of permanent neurological deficits occurred. Death occurred in 1 patient, unrelated to the stent. The ruptured status of the aneurysms (OR=3.29; p=0.046) and use of LVIS Jr for bailout (OR=2.54; p=0.053) showed a trend towards significant association with higher angiographic complications. At the last available follow-up, 68 class I, 20 class II, and 12 class III results were seen. CONCLUSIONS The LVIS Jr stent is a safe and effective device for stent-assisted coiling, with 3% permanent neurological complications. Stent-assisted coiling continues to be technically challenging in cases of ruptured aneurysms and bailout situations.
Collapse
Affiliation(s)
- Jai Jai Shiva Shankar
- Department of Diagnostic Imaging, QE II Health Sciences Centre, Halifax, Nova Scotia, Canada
| | - Aiman Quateen
- Division of Neuroradiology, Department of Diagnostic Imaging, The Ottawa Hospital, Ottawa, Canada
| | - Alain Weill
- Department of Radiology, Centre hospitalier de l'Université de Montréal (CHUM), Hopital Notre-Dame, Montreal, Quebec, Canada
| | - Donatella Tampieri
- Departments of Radiology, Neurology, and Neurosurgery, Montreal Neurological Hospital and Institute, Montreal, Quebec, Canada
| | - Maria Del Pilar Cortes
- Department of Radiology, Montreal Neurological Hospital and Institute, Montreal, Quebec, Canada
| | - Robert Fahed
- Department of Radiology, Centre hospitalier de l'Université de Montréal (CHUM), Hopital Notre-Dame, Montreal, Quebec, Canada
| | - Satya Patro
- Division of Neuroradiology, Department of Diagnostic Imaging, The Ottawa Hospital, Ottawa, Canada
| | - Zul Kaderali
- Section of Neurosurgery, Health Sciences Centre, Winnipeg, Canada
| | - Cheemun Lum
- Division of Neuroradiology, Department of Diagnostic Imaging, The Ottawa Hospital, Ottawa, Canada
| | - Howard Lesiuk
- Department of Neurosurgery, The Ottawa Hospital, Ottawa, Canada
| | - Uzair Ahmed
- Department of Neurosurgery, University of Saskatchewan, Saskatoon, Canada
| | - Lissa Peeling
- Department of Neurosurgery, University of Saskatchewan, Saskatoon, Canada
| | - Michael E Kelly
- Departments of Neurosurgery, Medical Imaging, Biomedical Engineering, & Anatomy and Cell Biology, University of Saskatchewan, Saskatoon, Canada
| | - Daniela Iancu
- Division of Neuroradiology, Department of Diagnostic Imaging, The Ottawa Hospital, Ottawa, Canada
| |
Collapse
|
9
|
Pérez MA, Bhogal P, Moreno RM, Wendl C, Bäzner H, Ganslandt O, Henkes H. Use of the pCONus as an adjunct to coil embolization of acutely ruptured aneurysms. J Neurointerv Surg 2016; 9:39-44. [PMID: 27411859 PMCID: PMC5264233 DOI: 10.1136/neurintsurg-2016-012508] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2016] [Revised: 06/09/2016] [Accepted: 06/17/2016] [Indexed: 11/24/2022]
Abstract
Introduction Coil embolization of ruptured aneurysms has become the standard treatment in many situations. However, certain aneurysm morphologies pose technical difficulties and may require the use of adjunctive devices. Objective To present our experience with the pCONus, a new neck bridging device, as an adjunct to coil embolization for acutely ruptured aneurysms and discuss the technical success, angiographic and clinical outcomes. Methods We conducted a retrospective review of our database of prospectively collected data to identify all patients who presented with acute subarachnoid hemorrhage that required adjunctive treatment with the pCONus in the acute stage. We searched the database between April 2011 and April 2016. Results 21 patients were identified (13 male, 8 female) with an average age of 54.6 years (range 31–73). 8 aneurysms were located at the basilar artery tip, 7 at the anterior communicating artery, 4 at the middle cerebral artery bifurcation, 1 pericallosal, and 1 basilar fenestration. 61.8% patients achieved modified Raymond–Roy classification I or II at immediate angiography, with 75% of patients having completely occluded aneurysms or stable appearance at initial follow-up. There were no repeat aneurysmal ruptures and two device-related complications (no permanent morbidity). Four patients in our cohort died. Conclusions Use of the pCONus is safe and effective in patients with acutely ruptured aneurysms and carries a high rate of technical success.
Collapse
Affiliation(s)
- M Aguilar Pérez
- Neuroradiological Clinic, Neurocenter, Klinikum Stuttgart, Stuttgart, Germany
| | - P Bhogal
- Neuroradiological Clinic, Neurocenter, Klinikum Stuttgart, Stuttgart, Germany
| | - R Martinez Moreno
- Neuroradiological Clinic, Neurocenter, Klinikum Stuttgart, Stuttgart, Germany
| | - C Wendl
- Neuroradiological Clinic, Neurocenter, Klinikum Stuttgart, Stuttgart, Germany
| | - H Bäzner
- Neurological Clinic, Neurocenter, Klinikum Stuttgart, Stuttgart, Germany
| | - O Ganslandt
- Neurosurgical Clinic, Neurocenter, Klinikum Stuttgart, Stuttgart, Germany
| | - H Henkes
- Neuroradiological Clinic, Neurocenter, Klinikum Stuttgart, Stuttgart, Germany.,Medical Faculty, University Duisburg-Essen, Germany
| |
Collapse
|