Chen Q, Rong Y, Burmeister JW, Chao EH, Corradini NA, Followill DS, Li XA, Liu A, Qi XS, Shi H, Smilowitz JB. AAPM Task Group Report 306: Quality control and assurance for tomotherapy: An update to Task Group Report 148. Med Phys 2023; 50:e25-e52. [PMID: 36512742 DOI: 10.1002/mp.16150] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2022] [Revised: 09/22/2022] [Accepted: 11/28/2022] [Indexed: 12/15/2022] Open
Abstract
Since the publication of AAPM Task Group (TG) 148 on quality assurance (QA) for helical tomotherapy, there have been many new developments on the tomotherapy platform involving treatment delivery, on-board imaging options, motion management, and treatment planning systems (TPSs). In response to a need for guidance on quality control (QC) and QA for these technologies, the AAPM Therapy Physics Committee commissioned TG 306 to review these changes and make recommendations related to these technology updates. The specific objectives of this TG were (1) to update, as needed, recommendations on tolerance limits, frequencies and QC/QA testing methodology in TG 148, (2) address the commissioning and necessary QA checks, as a supplement to Medical Physics Practice Guidelines (MPPG) with respect to tomotherapy TPS and (3) to provide risk-based recommendations on the new technology implemented clinically and treatment delivery workflow. Detailed recommendations on QA tests and their tolerance levels are provided for dynamic jaws, binary multileaf collimators, and Synchrony motion management. A subset of TPS commissioning and QA checks in MPPG 5.a. applicable to tomotherapy are recommended. In addition, failure mode and effects analysis has been conducted among TG members to obtain multi-institutional analysis on tomotherapy-related failure modes and their effect ranking.
Collapse
Affiliation(s)
- Quan Chen
- Radiation Oncology, City of Hope Medical Center, Duarte, California, USA
| | - Yi Rong
- Department of Radiation Oncology, Mayo Clinic Hospitals, Phoenix, Arizona, USA
| | - Jay W Burmeister
- Karmanos Cancer Center, Gershenson R.O.C., Detroit, Michigan, USA
- Department of Oncology, Wayne State University School of Medicine, Detroit, Michigan, USA
| | | | | | - David S Followill
- Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - X Allen Li
- Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
| | - An Liu
- Radiation Oncology, City of Hope Medical Center, Duarte, California, USA
| | - X Sharon Qi
- Radiation Oncology, UCLA School of Medicine, Los Angeles, California, USA
| | - Hairong Shi
- Radiation Oncology, Oklahoma Cancer Specialists and Research Institute, Tulsa, Oklahoma, USA
| | - Jennifer B Smilowitz
- Human Oncology and Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| |
Collapse
|
2
|
Zhang J, Peng Y, Ding S, Zhu J, Liu Y, Chen M, Sun W, Zhou L, Deng X. Comparison of Different Combinations of Irradiation Mode and Jaw Width in Helical Tomotherapy for Nasopharyngeal Carcinoma. Front Oncol 2020; 10:598. [PMID: 32391275 PMCID: PMC7190867 DOI: 10.3389/fonc.2020.00598] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2020] [Accepted: 04/01/2020] [Indexed: 11/19/2022] Open
Abstract
Purpose: To aid in the selection of a suitable combination of irradiation mode and jaw width in helical tomotherapy (HT) for the treatment of nasopharyngeal carcinoma (NPC). Materials and Methods: Twenty patients with NPC who underwent radiotherapy were retrospectively selected. Four plans using a jaw width of 2.5 or 5-cm in dynamic jaw (DJ) or fix jaw (FJ) modes for irradiation were designed (2.5DJ, 2.5FJ, 5.0DJ, and 5.0FJ). The dose parameters of planning target volume (PTV) and organs at risk (OARs) of the plans were compared and analyzed, as well as the beam on time (BOT) and monitor unit (MU). The plans in each group were ranked by scoring the doses received by the OARs and the superity was assessed in combination with the planned BOT and MU. Results: The prescribed dose coverage of PTV met the clinical requirements for all plans in the four groups. The groups using a 2.5-cm jaw width or a DJ mode provided better protection to most OARs, particularly for those at the longitudinal edges of the PTV (P < 0.05). The 2.5DJ group had the best ranking for OAR-dose, followed by the 2.5FJ and 5.0DJ groups with a same score. The BOT and MU of the groups using a 5.0-cm jaw width reduced nearly 45% comparing to those of the 2.5-cm jaw groups. Conclusion: 2.5DJ has the best dose distribution, while 5.0DJ has satisfactory dose distribution and less BOT and MU that related to the leakage dose. Both 2.5DJ or 5DJ were recommended for HT treatment plan for NPC based on the center workload.
Collapse
Affiliation(s)
- Jun Zhang
- Department of Radiation Oncology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangzhou, China.,School of Biomedical Engineering, Southern Medical University, Guangzhou, China
| | - Yinglin Peng
- Department of Radiation Oncology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangzhou, China.,School of Biomedical Engineering, Sun Yat-sen University, Guangzhou, China
| | - Shouliang Ding
- Department of Radiation Oncology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangzhou, China
| | - Jinhan Zhu
- Department of Radiation Oncology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangzhou, China
| | - Yimei Liu
- Department of Radiation Oncology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangzhou, China
| | - Meining Chen
- Department of Radiation Oncology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangzhou, China
| | - Wenzhao Sun
- Department of Radiation Oncology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangzhou, China
| | - Linghong Zhou
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China
| | - Xiaowu Deng
- Department of Radiation Oncology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangzhou, China
| |
Collapse
|
3
|
Schmitt D, Blanck O, Gauer T, Fix MK, Brunner TB, Fleckenstein J, Loutfi-Krauss B, Manser P, Werner R, Wilhelm ML, Baus WW, Moustakis C. Technological quality requirements for stereotactic radiotherapy : Expert review group consensus from the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. Strahlenther Onkol 2020; 196:421-443. [PMID: 32211939 PMCID: PMC7182540 DOI: 10.1007/s00066-020-01583-2] [Citation(s) in RCA: 66] [Impact Index Per Article: 16.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2020] [Accepted: 01/13/2020] [Indexed: 12/25/2022]
Abstract
This review details and discusses the technological quality requirements to ensure the desired quality for stereotactic radiotherapy using photon external beam radiotherapy as defined by the DEGRO Working Group Radiosurgery and Stereotactic Radiotherapy and the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. The covered aspects of this review are 1) imaging for target volume definition, 2) patient positioning and target volume localization, 3) motion management, 4) collimation of the irradiation and beam directions, 5) dose calculation, 6) treatment unit accuracy, and 7) dedicated quality assurance measures. For each part, an expert review for current state-of-the-art techniques and their particular technological quality requirement to reach the necessary accuracy for stereotactic radiotherapy divided into intracranial stereotactic radiosurgery in one single fraction (SRS), intracranial fractionated stereotactic radiotherapy (FSRT), and extracranial stereotactic body radiotherapy (SBRT) is presented. All recommendations and suggestions for all mentioned aspects of stereotactic radiotherapy are formulated and related uncertainties and potential sources of error discussed. Additionally, further research and development needs in terms of insufficient data and unsolved problems for stereotactic radiotherapy are identified, which will serve as a basis for the future assignments of the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. The review was group peer-reviewed, and consensus was obtained through multiple working group meetings.
Collapse
Affiliation(s)
- Daniela Schmitt
- Klinik für Radioonkologie und Strahlentherapie, National Center for Radiation Research in Oncology (NCRO), Heidelberger Institut für Radioonkologie (HIRO), Universitätsklinikum Heidelberg, Heidelberg, Germany.
| | - Oliver Blanck
- Klinik für Strahlentherapie, Universitätsklinikum Schleswig-Holstein, Kiel, Germany
| | - Tobias Gauer
- Klinik für Strahlentherapie und Radioonkologie, Universitätsklinikum Hamburg-Eppendorf, Hamburg, Germany
| | - Michael K Fix
- Abteilung für Medizinische Strahlenphysik und Universitätsklinik für Radio-Onkologie, Inselspital-Universitätsspital Bern, Universität Bern, Bern, Switzerland
| | - Thomas B Brunner
- Universitätsklinik für Strahlentherapie, Universitätsklinikum Magdeburg, Magdeburg, Germany
| | - Jens Fleckenstein
- Klinik für Strahlentherapie und Radioonkologie, Universitätsmedizin Mannheim, Universität Heidelberg, Mannheim, Germany
| | - Britta Loutfi-Krauss
- Klinik für Strahlentherapie und Onkologie, Universitätsklinikum Frankfurt, Frankfurt am Main, Germany
| | - Peter Manser
- Abteilung für Medizinische Strahlenphysik und Universitätsklinik für Radio-Onkologie, Inselspital-Universitätsspital Bern, Universität Bern, Bern, Switzerland
| | - Rene Werner
- Institut für Computational Neuroscience, Universitätsklinikum Hamburg-Eppendorf, Hamburg, Germany
| | - Maria-Lisa Wilhelm
- Klinik für Strahlentherapie, Universitätsmedizin Rostock, Rostock, Germany
| | - Wolfgang W Baus
- Klinik für Radioonkologie, CyberKnife- und Strahlentherapie, Universitätsklinikum Köln, Cologne, Germany
| | - Christos Moustakis
- Klinik für Strahlentherapie-Radioonkologie, Universitätsklinikum Münster, Münster, Germany
| |
Collapse
|
4
|
Chou YH, Lu YC, Peng SL, Lee SC, Hsieh LL, Shih CT. Evaluation of the dose distribution of tomotherapy using polymer gel dosimeters and optical computed tomography with ring artifact correction. Radiat Phys Chem Oxf Engl 1993 2020. [DOI: 10.1016/j.radphyschem.2019.108572] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
5
|
Reynoso FJ, Hugo GD, Mutic S, Gach HM, Knutson NC. Lateral head flexion as a noncoplanar solution for ring gantry stereotactic radiosurgery. Med Phys 2019; 47:1181-1188. [PMID: 31840258 DOI: 10.1002/mp.13962] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2019] [Revised: 10/21/2019] [Accepted: 12/04/2019] [Indexed: 11/10/2022] Open
Abstract
PURPOSE Ring gantry radiotherapy devices are often limited to deliver beams in the axial plane, severely limiting beam entrance angles and rendering noncoplanar beam delivery impossible. However, a ring gantry geometry greatly simplifies delivery machines and increases the efficiency of treatment with the potential to decrease the overall costs of radiotherapy. This study explores the use of lateral head flexion in order to increase beam entrance angles and extend the available solid angle space for a ring gantry stereotactic radiosurgery (SRS) application. MATERIALS AND METHODS A 1.5 T magnetic resonance imaging scanner was used to scan seven healthy volunteers at three different head positions: a neutral position, a left lateral flexion position and a right lateral flexion position. The lateral flexion scans were co-registered to the neutral head position scan using rigid registration and extracting the rotational transformation. The head pitch, roll, and yaw were computed for each registration to evaluate the natural range of motion for all volunteers. A ring gantry plan geometry was used to generate two sets of single fraction SRS plans (21 Gy): one coplanar set for head neutral scans, and a three-arc plan set using the head neutral and lateral head flexion scans. The conformity index (CI), intermediate dose fall-off (R50), low dose spillage (R10), and gradient measure (GM) were used to evaluate both sets of plans. The treatment plans were generated for a ring-gantry linear accelerator (linac) (Varian Halcyon 2.0) as well as radiosurgery linac (Varian Edge) for comparison. RESULTS The average pitch, yaw, and roll for the lateral head flexion scans were 4.1° ± 4.7°, 16.9° ± 3.7°, and 2.5° ± 4.9° for the right flexion and 4.9° ± 4.3°, 14.0° ± 3.7° and 2.8° ± 5.4° for left flexion. When comparing the head flexion technique with a fully coplanar geometry, the ring gantry plans showed an average improvement in CI of 7.3% (1.46 ± 0.25 vs 1.36 ± 0.28), a decrease of 13% in R50 (5.46 ± 1.14 vs 4.78 ± 1.12), a decrease of 32% in R10 (85.7 ± 20.3 vs 58.2 ± 15.1), and a decrease of 7.8% in GM (0.53 ± 0.05 vs 0.49 ± 0.04). The Edge plans showed an average improvement in CI of 3.0% (1.49 ± 0.26 vs 1.45 ± 0.25), a decrease of 6.8% in R50 (5.19 ± 1.03 vs 4.82 ± 0.83), a decrease of 29% in R10 (84.1 ± 16.3 vs 59.9 ± 12.5), and a decrease of 5.0% in GM (0.50 ± 0.04 vs 0.47 ± 0.03). CONCLUSION Lateral head flexion was shown to increase beam entrance angles considerably improving plan conformity and normal tissue sparing in this pilot study of seven sets of plans. Rigid registrations demonstrated each lateral flexion to be analogous to a 15° couch kick. The head flexion technique outlined here was shown to be a feasible solution for SRS treatments being delivered on ring gantry devices.
Collapse
Affiliation(s)
- Francisco J Reynoso
- Departments of Radiation Oncology, Washington University School of Medicine, St. Louis, MO, 63110, USA
| | - Geoffrey D Hugo
- Departments of Radiation Oncology, Washington University School of Medicine, St. Louis, MO, 63110, USA.,Departments of Biomedical Engineering, Washington University School of Medicine, St. Louis, MO, 63110, USA
| | - Sasa Mutic
- Departments of Radiation Oncology, Washington University School of Medicine, St. Louis, MO, 63110, USA
| | - H Michael Gach
- Departments of Radiation Oncology, Washington University School of Medicine, St. Louis, MO, 63110, USA.,Departments of Biomedical Engineering, Washington University School of Medicine, St. Louis, MO, 63110, USA.,Departments of Radiology, Washington University School of Medicine, St. Louis, MO, 63110, USA
| | - Nels C Knutson
- Departments of Radiation Oncology, Washington University School of Medicine, St. Louis, MO, 63110, USA
| |
Collapse
|
6
|
Liao X, Li J, Wang P, Yao X, Zhang Y, Tan T, Orlandini LC. Feasibility of a Skin Dose Reduction for Nasopharyngeal Carcinoma Treated With High-Intensity-Modulated Delivery Techniques. Technol Cancer Res Treat 2018; 17:1533033818803582. [PMID: 30343642 PMCID: PMC6198397 DOI: 10.1177/1533033818803582] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022] Open
Abstract
Acute skin toxicity observed in radiotherapy treatment of head and neck cancer is a big concern. The purpose of this work is to evaluate the feasibility of a skin dose reduction in the treatment of nasopharyngeal carcinoma without compromising the overall plan quality. This research focused on comparison of the skin dose reduction that can be obtained for the main high conformal radiotherapy delivery techniques. Sixteen cases of early-stage nasopharyngeal carcinoma were included in this study. For each case, a dynamic intensity-modulated radiation therapy, a volumetric modulated arc therapy, and a helical tomotherapy treatment plans were performed with and without the skin as a sensitive structure in the inverse plan optimization. The dosimetric results obtained for the different treatment techniques and plan optimizations were compared. Dose–volume histogram cutoff points of D95%, D98%, and the homogeneity index were used for target comparison, while Dmean and Dmax/D1cc were used for the organs at risk. The skin volume receiving 5 Gy and then 10 to 70 Gy of radiation dosage registered at step of 10 Gy and Dmean were used for the skin dose comparison. One-way analysis of variance was used to assess the dosimetric results obtained for the different types of treatment plans and techniques investigated. A total of 96 treatment plans were analyzed. When the neck skin was considered in the treatment optimization process, the skin volume that received more than 30 Gy was reduced by 3.7% for dynamic intensity modulated, 4.1% for volumetric modulated arc, and 4.3% for dynamic intensity modulated, while the target dose coverage and organs at risk dosages remained unvaried (p > .05).
Collapse
Affiliation(s)
- Xiongfei Liao
- 1 Department of Radiation Oncology, Sichuan Cancer Hospital & Research Institute, Chengdu, China
| | - Jie Li
- 1 Department of Radiation Oncology, Sichuan Cancer Hospital & Research Institute, Chengdu, China
| | - Pei Wang
- 1 Department of Radiation Oncology, Sichuan Cancer Hospital & Research Institute, Chengdu, China
| | - Xinghong Yao
- 1 Department of Radiation Oncology, Sichuan Cancer Hospital & Research Institute, Chengdu, China
| | - Yulei Zhang
- 1 Department of Radiation Oncology, Sichuan Cancer Hospital & Research Institute, Chengdu, China
| | - Tingqiang Tan
- 1 Department of Radiation Oncology, Sichuan Cancer Hospital & Research Institute, Chengdu, China
| | - Lucia Clara Orlandini
- 1 Department of Radiation Oncology, Sichuan Cancer Hospital & Research Institute, Chengdu, China
| |
Collapse
|
7
|
Katayama S, Haefner MF, Mohr A, Schubert K, Oetzel D, Debus J, Sterzing F. Accelerated tomotherapy delivery with TomoEdge technique. J Appl Clin Med Phys 2015; 16:4964. [PMID: 26103170 PMCID: PMC5690089 DOI: 10.1120/jacmp.v16i2.4964] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2014] [Revised: 11/28/2014] [Accepted: 10/28/2014] [Indexed: 11/30/2022] Open
Abstract
TomoEDGE is an advanced delivery form of tomotherapy which uses a dynamic secondary collimator. This plan comparison study describes the new features, their clinical applicability, and their effect on plan quality and treatment speed. For the first 45 patients worldwide that were scheduled for a treatment with TomoEdge, at least two plans were created: one with the previous “standard”mode with static jaws and 2.5 cm field width (Reg 2.5) and one with TomoEdge technique and 5 cm field width (Edge 5). If, after analysis in terms of beam on time, integral dose, dose conformity, and organ at risk sparing the treating physician decided that the Edge 5 plan was not suitable for clinical treatment, a plan with TomoEdge and 2.5 cm field width was created (Edge 2.5) and used for the treatment. Among the 45 cases, 30 were suitable for Edge 5 treatment, including treatments of the head and neck, rectal cancer, anal cancer, malignancies of the chest, breast cancer, and palliative treatments. In these cases, the use of a 5 cm field width reduced beam on time by more than 30% without compromising plan quality. The 5 cm beam could not be clinically applied to treatments of the pelvic lymph nodes for prostate cancer and to head and neck irradiations with extensive involvement of the skull, as dose to critical organs at risk such as bladder (average dose 28 Gy vs. 29 Gy, Reg 2.5 vs. Edge 5), small bowel (29% vs. 31%, Reg 2.5 vs. Edge 5) and brain (average dose partial brain 19 Gy vs. 21 Gy, Reg 2.5 vs. Edge 5) increased to a clinically relevant, yet not statistically significant, amount. TomoEdge is an advantageous extension of the tomotherapy technique that can speed up treatments and thus increase patient comfort and safety in the majority of clinical settings. PACS numbers: 87.55.de, 87.55ne
Collapse
Affiliation(s)
- Sonja Katayama
- Department of Radiation Oncology, University Hospital Heidelberg, Germany.
| | | | | | | | | | | | | |
Collapse
|
8
|
Zwicker F, Swartman B, Roeder F, Sterzing F, Hauswald H, Thieke C, Weber KJ, Huber PE, Schubert K, Debus J, Herfarth K. In vivo measurement of dose distribution in patients' lymphocytes: helical tomotherapy versus step-and-shoot IMRT in prostate cancer. JOURNAL OF RADIATION RESEARCH 2015; 56:239-247. [PMID: 25361548 PMCID: PMC4380044 DOI: 10.1093/jrr/rru096] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/07/2014] [Revised: 09/07/2014] [Accepted: 09/13/2014] [Indexed: 06/04/2023]
Abstract
In radiotherapy, in vivo measurement of dose distribution within patients' lymphocytes can be performed by detecting gamma-H2AX foci in lymphocyte nuclei. This method can help in determining the whole-body dose. Options for risk estimations for toxicities in normal tissue and for the incidence of secondary malignancy are still under debate. In this investigation, helical tomotherapy (TOMO) is compared with step-and-shoot IMRT (SSIMRT) of the prostate gland by measuring the dose distribution within patients' lymphocytes. In this prospective study, blood was taken from 20 patients before and 10 min after their first irradiation fraction for each technique. The isolated leukocytes were fixed 2 h after radiation. DNA double-stranded breaks in lymphocyte nuclei were stained immunocytochemically using anti-gamma-H2AX antibodies. Gamma-H2AX foci distribution in lymphocytes was determined for each patient. Using a calibration line, dose distributions in patients' lymphocytes were determined by studying the gamma-H2AX foci distribution, and these data were used to generate a cumulative dose-lymphocyte histogram (DLH). Measured in vivo (DLH), significantly fewer lymphocytes indicated low-dose exposure (<40% of the applied dose) during TOMO compared with SSIMRT. The dose exposure range, between 45 and 100%, was equal with both radiation techniques. The mean number of gamma-H2AX foci per lymphocyte was significantly lower in the TOMO group compared with the SSIMRT group. In radiotherapy of the prostate gland, TOMO generates a smaller fraction of patients' lymphocytes with low-dose exposure relative to the whole body compared with SSIMRT. Differences in the constructional buildup of the different linear accelerator systems, e.g. the flattening filter, may be the cause thereof. The influence of these methods on the incidence of secondary malignancy should be investigated in further studies.
Collapse
Affiliation(s)
- Felix Zwicker
- Department of Radiation Oncology, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Benedict Swartman
- Department of Radiation Oncology, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany
| | - Falk Roeder
- Department of Radiation Oncology, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Florian Sterzing
- Department of Radiation Oncology, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Henrik Hauswald
- Department of Radiation Oncology, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany
| | - Christian Thieke
- Department of Radiation Oncology, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Klaus-Josef Weber
- Department of Radiation Oncology, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany
| | - Peter E Huber
- Department of Radiation Oncology, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Kai Schubert
- Department of Radiation Oncology, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany
| | - Jürgen Debus
- Department of Radiation Oncology, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Klaus Herfarth
- Department of Radiation Oncology, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany
| |
Collapse
|
9
|
Rong Y, Chen Y, Shang L, Zuo L, Lu W, Chen Q. Helical tomotherapy with dynamic running-start-stop delivery compared to conventional tomotherapy delivery. Med Phys 2014; 41:051709. [PMID: 24784375 DOI: 10.1118/1.4870987] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Despite superior target dose uniformity, helical tomotherapy(®) (HT) may involve a trade-off between longitudinal dose conformity and beam-on time (BOT), due to the limitation of only three available jaw sizes with the conventional HT (1.0, 2.5, and 5.0 cm). The recently introduced dynamic running-start-stop (RSS) delivery allows smaller jaw opening at the superior and inferior ends of the target when a sharp penumbra is needed. This study compared the dosimetric performance of RSS delivery with the fixed jaw HT delivery. METHODS Twenty patient cases were selected and deidentified prior to treatment planning, including 16 common clinical cases (brain, head and neck (HN), lung, and prostate) and four special cases of whole brain with hippocampus avoidance (WBHA) that require a high degree of dose modulation. HT plans were generated for common clinical cases using the fixed 2.5 cm jaw width (HT2.5) and WBHA cases using 1.0 cm (HT1.0). The jaw widths for RSS were preset with a larger size (RSS5.0 vs HT2.5 and RSS2.5 vs HT1.0). Both delivery techniques were planned based on identical contours, prescriptions, and planning objectives. Dose indices for targets and critical organs were compared using dose-volume histograms, BOT, and monitor units. RESULTS The average BOT was reduced from 4.8 min with HT2.5 to 2.5 min with RSS5.0. Target dose homogeneity with RSS5.0 was shown comparable to HT2.5 for common clinical sites. Superior normal tissue sparing was observed in RSS5.0 for optic nerves and optic chiasm in brain and HN cases. RSS5.0 demonstrated improved dose sparing for cord and esophagus in lung cases, as well as penile bulb in prostate cases. The mean body dose was comparable for both techniques. For the WBHA cases, the target homogeneity was significantly degraded in RSS2.5 without distinct dose sparing for hippocampus, compared to HT1.0. CONCLUSIONS Compared to the fixed jaw HT delivery, RSS combined with a larger jaw width provides faster treatment delivery and improved cranial-caudal target dose conformity. The target coverage achieved by RSS with a large jaw width is comparable to the fixed jaw HT delivery for common cancer sites, but may deteriorate for cases where complex geometry is present in the middle part of the target.
Collapse
Affiliation(s)
- Yi Rong
- Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Columbus, Ohio 43210
| | - Yu Chen
- 21st Century Oncology, Madison, Wisconsin 53719
| | - Lu Shang
- Guangxi Polytechnic of Construction and Technology, Nanning, China
| | - Li Zuo
- Radiologic Sciences and Respiratory Therapy Division, School of Health and Rehabilitation Sciences, The Ohio State University College of Medicine, Columbus, Ohio 43210
| | - Weiguo Lu
- 21st Century Oncology, Madison, Wisconsin 53719
| | - Quan Chen
- Department of Radiation Oncology, University of Virginia, Charlottesville, Virginia 22904
| |
Collapse
|
10
|
Manabe Y, Shibamoto Y, Sugie C, Hayashi A, Murai T, Yanagi T. Helical and Static-port Tomotherapy Using the Newly-developed Dynamic Jaws Technology for Lung Cancer. Technol Cancer Res Treat 2014; 14:583-91. [PMID: 24945375 PMCID: PMC4639908 DOI: 10.7785/tcrtexpress.2013.600280] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2014] [Accepted: 06/05/2014] [Indexed: 11/19/2022] Open
Abstract
With the newly developed dynamic jaws technology, radiation dose for the cranio-caudal edges of a target can be lowered in the treatment with tomotherapy. We compared dynamic-jaw- and fixed-jaw-mode plans for lung cancer. In 35 patients, four plans using the 2.5-cm dynamic-, 2.5-cm fixed-, 5.0-cm dynamic-, and 5.0-cm fixed-jaw modes were generated. For 10 patients with upper lobe stage I lung cancer, the helical tomotherapy mode was used. Fifty-six Gy in 8 fractions was prescribed as a minimum coverage dose for 95% of the target (D95%). For 25 patients with locally advanced lung cancer, plans using four static ports (TomoDirect® mode) were made. Sixty Gy in 30 daily fractions for the primary tumor and swollen lymph nodes and 51 Gy in 30 fractions for prophylactic lymph node areas were prescribed as median doses. The mean conformity index of the planning target volume were similar among the four plans. The mean V5 Gy of the lung for 2.5-cm dynamic-, 2.5-cm fixed-, 5.0-cm dynamic-, and 5.0-cm fixed-jaw mode plans were 18.5%, 21.8%, 20.1%, and 29.4%, respectively (p < 0.0001), for patients with stage I lung cancer, and 37.3%, 38.7%, 40.4%, and 44.0%, respectively (p < 0.0001), for patients with locally advanced lung cancer. The mean V5 Gy of the whole body was 1,826, 2,143, 1,983, and 2,939 ml, respectively (p < 0.0001), for patients with stage I lung cancer and 4,849, 5,197, 5,220, and 6,154 ml, respectively (p < 0.0001), for patients with locally advanced lung cancer. Treatment time was reduced by 21-39% in 5.0-cm dynamic-jaw plans compared to 2.5-cm plans. Regarding dose distribution, 2.5-cm dynamic-jaw plans were the best, and 5.0-cm dynamic-jaw plans were comparable to 2.5-cm fixed-jaw plans with shorter treatment times. The dynamic-jaw mode should be used instead of the conventional fixed-jaw mode in tomotherapy for lung cancer.
Collapse
Affiliation(s)
- Yoshihiko Manabe
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya 467-8601, Japan
| | - Yuta Shibamoto
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya 467-8601, Japan
| | - Chikao Sugie
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya 467-8601, Japan
| | - Akihiro Hayashi
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya 467-8601, Japan
| | - Taro Murai
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya 467-8601, Japan
| | - Takeshi Yanagi
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya 467-8601, Japan
| |
Collapse
|
11
|
Sugie C, Manabe Y, Hayashi A, Murai T, Takaoka T, Hattori Y, Iwata H, Takenaka R, Shibamoto Y. Efficacy of the Dynamic Jaw Mode in Helical Tomotherapy With Static Ports for Breast Cancer. Technol Cancer Res Treat 2014; 14:459-65. [PMID: 25398681 PMCID: PMC4535315 DOI: 10.1177/1533034614558746] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2014] [Accepted: 10/06/2014] [Indexed: 11/30/2022] Open
Abstract
The recently developed dynamic jaw technology of tomotherapy can reduce craniocaudal dose spread without much prolonging the treatment time. This study aimed to investigate the efficacy of the dynamic jaw mode for tomotherapy of breast cancer. Static tomotherapy plans of the whole breast and supraclavicular regional lymph nodes, and plans for the whole breast only were generated in 25 patients with left-sided breast cancer. Plans with a field width of 2.5 or 5 cm with the dynamic or fixed jaw modes were made for each patient. The prescribed dose was 50 Gy in 25 fractions. In whole breast and supraclavicular nodal radiotherapy, dose distributions and homogeneity of the planning target volume (PTV) with the dynamic jaw mode were slightly inferior to those with the fixed jaw mode with a 5-cm field width (P < .05). However, lung low-dose volumes and mean doses of the larynx, thyroid, skin, and all the healthy tissues combined were smaller with the dynamic jaw mode than with the fixed jaw mode with a 5-cm field width (P < .001). In whole breast radiotherapy, mean doses of the skin and healthy tissues were lower with the dynamic jaw mode than with the fixed jaw mode with a 5-cm field width (P < .001) without significant differences in PTV dose distributions, homogeneity, and conformity. The dynamic jaw mode provided better sparing of organs at risks with minimal disturbance of dose–volume indices of PTV. Considering the treatment time, the 5-cm-field dynamic jaw mode is more efficient than the 2.5-cm fixed jaw mode.
Collapse
Affiliation(s)
- Chikao Sugie
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| | - Yoshihiko Manabe
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| | - Akihiro Hayashi
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan Department of Radiology, Okazaki City Hospital, Okazaki, Japan
| | - Taro Murai
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| | - Taiki Takaoka
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| | - Yukiko Hattori
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan Department of Radiation Oncology, Nagoya Proton Therapy Center, Nagoya, Japan
| | - Hiromitsu Iwata
- Department of Radiation Oncology, Nagoya Proton Therapy Center, Nagoya, Japan
| | - Ran Takenaka
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan Department of Radiology, Narita Memorial Hospital, Toyohashi, Japan
| | - Yuta Shibamoto
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| |
Collapse
|
12
|
Hauswald H, Habl G, Krug D, Kehle D, Combs SE, Bermejo JL, Debus J, Sterzing F. Whole brain helical Tomotherapy with integrated boost for brain metastases in patients with malignant melanoma-a randomized trial. Radiat Oncol 2013; 8:234. [PMID: 24112545 PMCID: PMC3816313 DOI: 10.1186/1748-717x-8-234] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2013] [Accepted: 10/07/2013] [Indexed: 12/19/2022] Open
Abstract
BACKGROUND Patients with malignant melanoma may develop brain metastases during the course of the disease, requiring radiotherapeutic treatment. In patients with 1-3 brain metastases, radiosurgery has been established as a treatment option besides surgery. For patients with 4 or more brain metastases, whole brain radiotherapy is considered the standard treatment. In certain patients with brain metastases, radiation treatment using whole brain helical Tomotherapy with integrated boost and hippocampal-sparing may improve prognosis of these patients. METHODS/DESIGN The present prospective, randomized two-armed trial aims to exploratory investigate the treatment response to conventional whole brain radiotherapy applying 30 Gy in 10 fractions versus whole brain helical Tomotherapy applying 30 Gy in 10 fractions with an integrated boost of 50 Gy to the brain metastases as well as hippocampal-sparing in patients with brain metastases from malignant melanoma. The main inclusion criteria include magnetic resonance imaging confirmed brain metastases from a histopathologically confirmed malignant melanoma in patients with a minimum age of 18 years. The main exclusion criteria include a previous radiotherapy of the brain and not having recovered from acute high-grade toxicities of prior therapies. The primary endpoint is treatment-related toxicity. Secondary endpoints include imaging response, local and loco-regional progression-free survival, overall survival and quality of life. TRIAL REGISTRATION http://www.drks.de Trial ID: DRKS00005127.
Collapse
Affiliation(s)
- Henrik Hauswald
- Department of Radiation Oncology, University Hospital of Heidelberg, INF 400, 69120, Heidelberg, Germany.
| | | | | | | | | | | | | | | |
Collapse
|