Nair D, Martinek MR, Colley J, Sundaram S, Hariharan R, Morales G, Sommer P, Healy S, Siddiqui U, Williams C, Sarver A, Lo M. Paroxysmal atrial fibrillation ablation with a novel flexible tip radiofrequency catheter incorporating contact force sensing: acute results of the TactiFlex AF IDE trial. Eur Heart J 2022. [DOI: 10.1093/eurheartj/ehac544.584] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Abstract
Background
Catheter ablation is an established therapy for paroxysmal atrial fibrillation (PAF). The TactiFlex™ Ablation Catheter, Sensor-Enabled™ (TactiFlex SE) is a next-generation radiofrequency ablation catheter incorporating highly accurate fiber optics-based contact force sensing technology with a flexible, laser-cut tip.
Purpose
To demonstrate that ablation with TactiFlex SE is safe and effective for the treatment of drug refractory, symptomatic PAF.
Methods
The TactiFlex AF IDE is a prospective, non-randomized, multi-center clinical study which enrolled 355 subjects worldwide. Enrollment in the main study began on June 26, 2020 and completed on June 18, 2021. Subjects underwent de novo Pulmonary Vein Isolation (PVI) and, if indicated, a Cavotricuspid Isthmus ablation (CTI line) for CTI-dependent atrial flutter.
Results
Subjects were divided into two as treated subgroups: High Standard Power (HSP, n=189), defined as subjects with 100% of left atrial lesions ablated at ≥40 W, and Low Standard Power (LSP, n=119), defined as subjects with at least one left atrial lesion ablated at <40W. First pass success, defined as isolation of all pulmonary veins (PVs) confirmed after a minimum 20 min waiting period was achieved in 93.5% (175/186) and 84.5% (98/116) of HSP and LSP subjects, respectively (p=0.0104). Significant decreases in the HSP versus LSP procedures were also seen in total procedure time (112.0 min [89.0, 139.5] and 149.0 [115.0, 182.0], respectively [p<0.001]), total RF time for PV ablation (14.0 min [11.0, 19.0] and 29.0 [19.0, 41.0], respectively [p<0.0001]), total fluoroscopy time (4.0 min [0.0, 11.0] and 8.0 [3.0, 17.0], respectively [p<0.0001]) and irrigation fluid volume (378.0 mL [310.0, 466.0] and 636.0 [476.0, 829.0], respectively [p<0.0001]) (values given as Median [Q1, Q3]), see Figure 1. Both HSP and LSP subjects had a low rate of repeat procedures (1.6% [3/182] and 4.3% [5/115], respectively [p=0.2684]) and primary safety endpoint events (4.8% [9/189] and 4.2% [5/119], respectively [p=0.8182]) through 90 days post-index procedure.
Conclusion
The acute data on the TactiFlex SE catheter demonstrates safe and effective treatment of PAF using either a HSP or LSP ablation strategy. Ablation procedures performed using a HSP strategy were shorter and required less irrigation fluid and fluoroscopy. It is anticipated these results will be reflected in the 12-month safety and effectiveness primary endpoints.
Funding Acknowledgement
Type of funding sources: Private company. Main funding source(s): Abbott
Collapse
Affiliation(s)
- D Nair
- St. Bernards Medical Center , Jonesboro , United States of America
| | - M R Martinek
- A. o. Krankenhaus her Elisabethinen Linz , Linz , Austria
| | - J Colley
- Jackson Heart Clinic , Jackson , United States of America
| | - S Sundaram
- South Denver Cardiology Associates PC , Littleton , United States of America
| | - R Hariharan
- Memorial Hermann Hospital , Houston , United States of America
| | - G Morales
- Affinity Cardiovascular Specialists, LLC , Birmingham , United States of America
| | - P Sommer
- Heart and Diabetes Center NRW , Bad Oeynhausen , Germany
| | - S Healy
- Monash Medical Centre , Melbourne , Australia
| | - U Siddiqui
- Advent Health Orlando , Orlando , United States of America
| | - C Williams
- Abbott , Saint Paul , United States of America
| | - A Sarver
- Abbott , Saint Paul , United States of America
| | - M Lo
- Arkansas Heart Hospital , Little Rock , United States of America
| |
Collapse
|
2
|
Nair D, Martinek M, Colley J, Sundaram S, Sharma S, Morales G, Sommer P, Healy S, Siddiqui U, Williams C, Sarver A, Lo M. Acute results of a novel flexible tip radiofrequency catheter incorporating contact force sensing. Europace 2022. [DOI: 10.1093/europace/euac053.077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Abstract
Funding Acknowledgements
Type of funding sources: Private company. Main funding source(s): Abbott
Background
Catheter ablation is an established therapy for paroxysmal atrial fibrillation (PAF). The TactiFlex Ablation Catheter, Sensor-Enabled (TactiFlex SE) is a next-generation radiofrequency ablation catheter incorporating highly accurate fiber optics-based contact force sensing technology with a flexible, laser-cut tip. This is the first report of results from the TactiFlex IDE clinical study.
Purpose
To demonstrate that ablation with TactiFlex SE is safe and effective for the treatment of drug refractory, symptomatic PAF.
Methods
The TactiFlex IDE (NCT04356040) is a prospective, non-randomized, multi-center clinical study which enrolled 305 subjects worldwide in the main study. Enrollment in the main study began on June 26, 2020 and completed on June 8, 2021. Subjects underwent de novo Pulmonary Vein Isolation (PVI) and, if indicated, a Cavotricuspid Isthmus ablation (CTI line) for CTI-dependent atrial flutter.
Results
Acute procedural success was achieved in 98.6% (274/278) of the main study cohort who underwent an ablation procedure using the TactiFlex SE. First pass success, defined as isolation of all pulmonary veins (PVs) confirmed after a minimum 20 min waiting period was achieved in 89.6% (249/278) of subjects. This was a significant improvement versus the TactiSense IDE trial (TactiCath Ablation Catheter, Sensor-Enabled). Significant decreases were also seen in total procedure time (123 min [101.0, 163.5]), total PV ablation time (55.5 min [35.0, 81.0]), total fluoroscopy time (6.0 min [0.0, 13.0]) and irrigation fluid volume (450.0 mL [346.0, 636.0]) (values given as Median [Q1, Q3]), see FIGURE. All subjects have completed at least 90 days of follow-up. Only 2.6% (7/271) of subjects required a repeat procedure during the 90-day blanking period. The primary safety and effectiveness endpoints will be evaluated at 12-months. At 90 days, 4.3% (12/281) subjects had experienced a primary safety endpoint event.
Conclusions
The acute data from the TactiFlex IDE clinical study demonstrate safety and effectiveness of the TactiFlex SE catheter in the treatment of PAF. Ablation procedures performed using the next-generation TactiFlex SE catheter were shorter and had improved acute clinical effectiveness outcomes versus the TactiSense IDE. It is anticipated these results will also be reflected in the 12-month safety and effectiveness endpoints.
Collapse
Affiliation(s)
- D Nair
- St. Bernards Medical Center, Jonesboro, United States of America
| | - M Martinek
- A. o. Krankenhaus her Elisabethinen Linz, Linz, Austria
| | - J Colley
- Jackson Heart Clinic, Jackson, United States of America
| | - S Sundaram
- South Denver Cardiology Associates PC, Denver, United States of America
| | - S Sharma
- Memorial Hermann Hospital, Houston, United States of America
| | - G Morales
- Affinity Cardiovascular Specialists, LLC, Birmingham, United States of America
| | - P Sommer
- Heart and Diabetes Center NRW, Bad Oeynhausen, Germany
| | - S Healy
- Monash Medical Center, Clayton, Australia
| | - U Siddiqui
- Advent Health Orlando, Orlando, United States of America
| | - C Williams
- Abbott, Saint Paul, United States of America
| | - A Sarver
- Abbott, Saint Paul, United States of America
| | - M Lo
- Arkansas Heart Hospital, Little Rock, United States of America
| |
Collapse
|
3
|
Sommer P, Spitzer S, Brachmann J, Janssen G, Lenz C, Luik A, Sarver A, Szili-Torok T. Final results from the EU focal impulse and rotor modulation (E-FIRM) registry. Europace 2021. [DOI: 10.1093/europace/euab116.089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Abstract
Funding Acknowledgements
Type of funding sources: Private company. Main funding source(s): Abbott
Background
The exact pathophysiology of how pulmonary vein (PV) triggers initiate or maintain episodes of atrial fibrillation (AF) has been elusive. Catheter ablation at relatively circumscribed areas of rapidly spinning rotors or very rapid focal impulse formation can significantly affect AF. Targeted ablation of these sources using Focal Impulse and Rotor Modulation (FIRM™) shows promise.
Purpose
To assess the safety and effectiveness of FIRM-guided procedures for the treatment of any type of symptomatic atrial fibrillation (AF).
Methods
Two hundred and ninety-nine subjects were enrolled in the E-FIRM Registry at 9 clinical sites in Germany and the Netherlands. Subjects were eligible if they had reported incidence of at least 2 documented episodes of symptomatic AF during the preceding 3 months and had failed at least Class I or III anti-arrhythmia drug. Data was collected at enrollment/baseline, procedure, and at 3-, 6-, and 12-month follow-up visits.
Results
A majority (59.5%, 178/299) had a history of previous ablation, 81.1% (133/164) in the left side, with an average of 1.5 ± 0.8 [range 0, 5] prior ablations. The primary safety endpoint was defined as freedom from procedure related Serious Adverse Events (SAEs) through 7-days and at 12-months. At 7-days, freedom from procedure related SAEs was 94.8% (257/271). At 12-months, freedom from procedure related SAEs was 84.4% (184/218). There were no deaths. Acute effectiveness success, defined as the elimination of all identified rotors, occurred in 64.0% (165/258) of treated patients. All patients for which data was reported had at least 1 rotor identified. The most common regions to find rotors were the lateral wall of the right atrium, the anterior/septal wall of the left atrium, and the posterior inferior region of the left atrium. 75.2% (194/258) of patients had at least one rotor identified in the right atrium, and 84.1% (217/258) of patients had at least one rotor identified in the left atrium. Success was defined as two sequential endpoints: single procedure freedom from AF recurrence at 3-months and single procedure freedom from AF recurrence. At 12-months, success was achieved in 46.4% (13/28) Paroxysmal, 42.9% (87/203) Persistent, and 0% (0/9) Long Standing AF subjects. Conclusions: Since acute success was reported as being achieved in only ∼2/3 of the treated subjects, it is possible that the full potential benefit of the FIRM-guided ablation was hidden in this evaluation of the full cohort. Considering the previous ablation and disease history of subjects, a single-procedure success rate at 12-months over 40% was considered a positive result. Based on these results, FIRM-guided RF ablation in conjunction with conventional RF ablation practices is both a safe and effective treatment strategy for patients with symptomatic AF.
Collapse
Affiliation(s)
- P Sommer
- Heart and Diabetes Center NRW, Bad Oeynhausen, Germany
| | - S Spitzer
- Praxis Klinik-Dresden, Dresden, Germany
| | | | - G Janssen
- Kardiologische Gemeinschaftspraxis am Park Sanssouci, Potsdam, Germany
| | - C Lenz
- UKB Berlin, Berlin, Germany
| | - A Luik
- Stadtisches Klinikum Karlsruhe, Karlsruhe, Germany
| | - A Sarver
- Abbott Laboratories, Plymouth, United States of America
| | - T Szili-Torok
- Erasmus University Medical Centre, Rotterdam, Netherlands (The)
| |
Collapse
|
4
|
Lin D, Glover B, Colley J, Thibault B, Steinberg C, Jewell C, Bernard M, Siddiqui U, Li J, Sarver A, Hsu J, Cooper D. Stability and performance of the EnSite Precision cardiac mapping system for electrophysiology mapping and ablation procedures: results from the EnSite Precision observational study. Eur Heart J 2020. [DOI: 10.1093/ehjci/ehaa946.0610] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Abstract
Background
The EnSite Precision™ Cardiac Mapping System is a catheter navigation and mapping system capable of displaying the three-dimensional (3D) position of conventional and sensor enabled electrophysiology catheters, as well as displaying cardiac electrical activity as waveform traces and dynamic 3-D maps of cardiac chambers.
Objective
The EnSite Precision™ Observational Study was designed to quantify and characterize the use of the EnSite Precision™ Cardiac Mapping System for mapping and ablation of cardiac arrhythmias in a real-world environment and to evaluate procedural and subsequent clinical outcomes.
Methods
1065 patients were enrolled at 38 centers in the U.S. and Canada between 2017–2018. Eligible subjects were adults undergoing a cardiac electrophysiology mapping and radiofrequency ablation procedures using the EnSite Precision™ System.
Results
Of 989 patients who completed the protocol, a geometry was created in 936 (94.7%). Most initial maps were created using Automap (n=545, 67.0%) or a combination of Automap and manually mapping (n=151, 18.6%). Median time to create an initial map was 9.0 min (IQR 5.0–15.0), with a median number of used mapping points per minute of 92.7 (IQR 30.0–192.0). During ablation, AutoMark was used in 817 (82.6%) of procedures. The most frequent metrics for lesion color were Impedance Drop or Impedance Drop Percent (45.5% combined), time (23.9%) and average force (14.2%). At Canadian sites where LSI was an option, it was used as the color metric in 87 (45.8%) of cases (10.6% overall). The EnSite System was stable throughout 79.7% (n=788 of 989) of procedures. Factors affecting stability were respiratory change (n=88 of 989, 8.9%), patient movement (n=73, 7.4%), CS Positional Reference dislodgement (n=32, 3.2%), and cardioversion (n=19, 1.9%). Conscious sedation was used in 189 (19.1%) of patients. Acute success was reached based on the pre-defined endpoints for the procedure in 97.4% (n=963) of cases.
Conclusion
In a real-world study analysis, the EnSite Precision™ mapping system was associated with a high prevalence of acute procedural success, low mapping times, and high system stability.
Funding Acknowledgement
Type of funding source: None
Collapse
Affiliation(s)
- D Lin
- Hospital of the University of Pennsylvania, Philadelphia, United States of America
| | - B Glover
- Kingston General Hospital and University of Toronto, Toronto, Canada
| | - J Colley
- Jackson Heart Clinic, Jackson, United States of America
| | - B Thibault
- Institut de Cardiologie, Montreal, Canada
| | | | - C Jewell
- Oklahoma Heart Hospital, Oklahoma City, United States of America
| | - M Bernard
- Ochsner Medical Center, New Orleans, United States of America
| | - U Siddiqui
- Florida Electrophysiology Associates, Orlando, United States of America
| | - J Li
- Abbott Laboratroies, Plymouth, MN, United States of America
| | - A Sarver
- Abbott Laboratroies, Plymouth, MN, United States of America
| | - J Hsu
- University of California, San Diego, San Diego, United States of America
| | - D Cooper
- Washington University School of Medicine, St Louis, United States of America
| |
Collapse
|
5
|
Tilz R, Lenz CL, Sommer PS, Sawan N, Meyer-Saraei R, Shpun S, Sarver A, Heeger C, Hindricks G, Vogler J, Eitel C. P2846Focal impulse and rotor modulation ablation versus pulmonary vein isolation for the treatment of paroxysmal atrial fibrillation (FIRMAP AF study). Eur Heart J 2019. [DOI: 10.1093/eurheartj/ehz748.1156] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Abstract
Background
Based on the assumption of trigger elimination, pulmonary vein isolation (PVI) currently presents the gold standard of atrial fibrillation (AF) ablation. Recently, rapidly spinning rotors or focal impulse formation has been raised as a crucial sustaining mechanism of AF. Ablation of these rotors may potentially obviate the need for trigger elimination with PVI.
Purpose
This study sought to compare the safety and effectiveness of Focal Impulse and Rotor Modulation (FIRM) guided catheter ablation only with the gold standard of pulmonary vein isolation (PVI) in patients with paroxysmal AF.
Methods
This was a post-market, prospective, single-blinded, randomized, multi-center trial. Patients were enrolled at three centers and equally (1:1) randomized between those undergoing conventional RF ablation with PVI (PVI group) vs. those treated with FIRM-guided RF ablation without PVI (FIRM group). Data was collected at enrollment, procedure, and at 7-day, 3-month, 6-month, and 12-month follow-up visits. The study was closed early by the sponsor. At the time of study closure, any pending follow-up visits were waived.
Results
From February 2016 until February 2018, a total of 51 (out of a planned 170) patients (mean age 63±10.6 years, 57% male) were enrolled and randomized. Four patients withdrew from the study prior to treatment, resulting in 23 patients allocated to the FIRM group and 24 in the PVI group. Only 13 patients in the FIRM group and 11 patients in the PVI group completed the 12-month follow-up. Statistical analysis was not completed given the small number of patients.
Single-procedure effectiveness (freedom from AF/atrial tachycardia recurrence after blanking period) was 52.9% (9/17) in the FIRM group and 85.7% (12/14) in the PVI group at 6 months; and 31.3% (5/16) in the FIRM group and 80% (8/10) in the PVI group at 12 months. Repeat procedures were performed in 45.8% (11/24) patients in the FIRM group and 7.4% (2/27) in the PVI group.
The acute safety endpoint [freedom from procedure-related serious adverse events (SAE)] was achieved in 87% (20/23) of FIRM group patients and 100% (24/24) of PVI group patients. Procedure related SAEs occurred in three patients in the FIRM group: 1 femoral artery aneurysm and 2 injection site hematomas. No additional procedure-related SAEs were reported >7 days post-procedure.
Conclusions
These partial study effectiveness results reinforce the importance of PVI in paroxysmal atrial fibrillation patients and suggest that FIRM-guided ablation alone (without PVI) is not an effective strategy for treatment of paroxysmal AF in most patients. Further study is needed to understand the effectiveness of adding FIRM-guided ablation as an adjunct to PVI in this patient group.
Acknowledgement/Funding
Abbot
Collapse
Affiliation(s)
- R Tilz
- University Heart Center, Luebeck, Germany
| | - C L Lenz
- UKB Berlin, Cardiology, Berlin, Germany
| | - P S Sommer
- Heart Center of Leipzig, Electrophysiology, Leipzig, Germany
| | - N Sawan
- University Heart Center, Luebeck, Germany
| | | | - S Shpun
- Abbot, Plymouth, United States of America
| | - A Sarver
- Abbot, Plymouth, United States of America
| | - C Heeger
- University Heart Center, Luebeck, Germany
| | - G Hindricks
- Heart Center of Leipzig, Electrophysiology, Leipzig, Germany
| | - J Vogler
- University Heart Center, Luebeck, Germany
| | - C Eitel
- University Heart Center, Luebeck, Germany
| |
Collapse
|
6
|
Becker M, Ibrahim Y, Byron S, Sarver A, Silverstein K, Lee A, Yee D. IGF-Induced Gene Profiles Are Dependent on IRS Expression and Convey Prognostic Value in Human Breast Cancer. Cancer Res 2009. [DOI: 10.1158/0008-5472.sabcs-09-3031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Abstract
The insulin-like growth factor (IGF) pathway mediates aberrant function during the initiation and progression of primary tumors and secondary metastases in cancer. As a result, a host of tyrosine kinase inhibitors and monoclonal antibodies directed against the type 1 IGF receptor (IGF-1R) have entered clinical trials with early positive results. However, no predictive biomarkers have yet emerged from these initial studies. We propose that expanding IGF biomarkers beyond IGF-1R alone may identify the most appropriate candidates for anti-IGF therapy. Previous work has shown that the insulin receptor substrate (IRS) proteins serve as the functional link between IGF-I-induced IGF-1R phosphorylation and downstream signaling linked to cellular behavior. Our work has demonstrated that IRS isoforms differentially mediate IGF-I action, whereby IRS-1 drives proliferation and IRS-2 triggers motility. Here we employed the T47D-YA (IRS null) breast cancer cell line and T47D-YA/IRS clones stably transfected with IRS-1 or IRS-2. In response to acute (4h) and chronic (24h) IGF-I stimulation, global gene expression patterns were assessed by Affymetrix U133 Plus 2.0 microarray analysis. Analysis revealed that IGF-1R activation alone was insufficient to affect gene expression as no genes were regulated by IGF-I in T47D-YA cells. Conversely, ligand stimulation of IRS-1 and IRS-2 clones induced or repressed hundreds of transcripts in both overlapping and distinct fashions. Direct comparison of IRS-1 to IRS-2 clones revealed a number of early (4h) IRS-2 genes linked to metastasis and late (24h) IRS-1 proliferative genes. Interestingly, a 10-fold upregulation in the transforming growth factor beta 2 (TGFβ2) gene by IGF-I in IRS-2 cells suggested a link between the IRS-derived gene signatures and the TGFβ pathway known to regulate breast cancer metastasis. We then compared our arrays with published IGF-I (MCF-7) and TGFβ-derived (MCF10A, MDA-231, HaCaT, HPL1) microarrays to find a list of commonly regulated genes and performed cluster analysis to reveal consistent patterns of gene expression (Creighton el al 2008 & Padua et al 2008). We found 75 genes that were regulated in common between these signatures. To explore the clinical relevance of the signatures we developed, we examined the NKI-295 dataset used to establish the 70-gene profile of prognosis and found 71 genes regulated in common between all four datasets (van de Vijver et al 2002). Strikingly, we discovered that patient survival was heavily influenced by the degree to which tumor expression correlated to the conserved signatures. A high degree of correlation resulted in the poorest disease free survival and an inverse correlation resulted in an improved disease free survival. Our data suggest that IGF stimulation of breast cancer cells results in distinct profiles of gene expression that are dependent on IRS adaptor protein expression. In addition, some of the “IRS-regulated” genes are shared in common with other gene signatures of poor prognosis. With the use of anti-IGF therapies in breast cancer, attention should focus on the use of these profiles as prognostic and predictive biomarkers.
Citation Information: Cancer Res 2009;69(24 Suppl):Abstract nr 3031.
Collapse
Affiliation(s)
- M. Becker
- 1Masonic Cancer Center, University of Minnesota, MN,
| | - Y. Ibrahim
- 1Masonic Cancer Center, University of Minnesota, MN,
| | - S. Byron
- 2Translational Genomics Research Institute, AZ,
| | - A. Sarver
- 1Masonic Cancer Center, University of Minnesota, MN,
| | | | - A. Lee
- 3Lester and Sue Smith Breast Center, Baylor College of Medicine, TX,
| | - D. Yee
- 1Masonic Cancer Center, University of Minnesota, MN,
| |
Collapse
|
7
|
Sarver A, Scheffler NK, Shetlar MD, Gibson BW. Analysis of peptides and proteins containing nitrotyrosine by matrix-assisted laser desorption/ionization mass spectrometry. J Am Soc Mass Spectrom 2001; 12:439-448. [PMID: 11322190 DOI: 10.1016/s1044-0305(01)00213-6] [Citation(s) in RCA: 121] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Oxidative damage to proteins can occur under physiological conditions through the action of reactive oxygen species, including those containing nitrogen such as peroxynitrite (ONO2-). Peroxynitrite has been shown in vitro to target tyrosine residues in proteins through free radical addition to produce 3-nitrotyrosine. In this work, we show that mass spectral patterns associated with 3-nitrotyrosine containing peptides allow identification of peptides containing this modification. Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry was used to characterize a synthetic peptide AAFGY(m-NO2)AR and several peptides containing 3-nitrotyrosine derived from bovine serum albumin treated with tetranitromethane. A unique series of ions were found for these peptides in addition to the mass shift of +45 Da corresponding to the addition of the nitro group. Specifically, two additional ions were observed at roughly equal abundance that correspond to the loss of one and two oxygens, and at lower abundances, two ions are seen that suggest the formation of hydroxylamine and amine derivatives. These latter four components appear to originate by laser-induced photochemical decomposition. MALDI-MS analysis of the synthetic peptide containing 3-nitrotyrosine revealed this same pattern. Post-source decay (PSD) MALDI-time-of-flight (TOF) and collisional activation using a prototype MALDI quadrupole TOF yielded extensive fragmentation that allowed site-specific identification of 3-nitrotyrosine. Conversion of peptides containing 3-nitrotyrosine to 3-aminotyrosine with Na2S2O4 yielded a single molecular ion by MALDI with an abundant sidechain loss under PSD conditions. These observations suggest that MALDI can provide a selective method for the analysis and characterization of 3-nitrotyrosine-containing peptides.
Collapse
Affiliation(s)
- A Sarver
- Department of Pharmaceutical Chemistry, University of California, San Francisco 94143-0446, USA
| | | | | | | |
Collapse
|