1
|
Loukas VS, Karanasiou GS, Pleouras D, Katsouras CC, Tachos NS, Sakellarios AI, Semertzioglou A, Michalis LK, Fotiadis DI. Investigation of crimping effects on the stent deployment through in silico modeling. Annu Int Conf IEEE Eng Med Biol Soc 2022; 2022:621-624. [PMID: 36085907 DOI: 10.1109/embc48229.2022.9871622] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Atherosclerosis is one of the most mortal diseases that affects the arterial vessels, due to accumulation of plaque, altering the hemodynamic environment of the artery by preventing the sufficient delivery of blood to other organs. Stents are expandable tubular wires, used as a treatment option. In silico studies have been extensively exploited towards examining the performance of such devices by employing Finite Element Modeling. This study models the crimping stage during stent implantation to examine the effect of inclusion of pre-stress state of the stent. The results show that modeling of the crimping stress state of the stent prior to the deployment results in under-expansion of the stent, due to the indirect inclusion of strain-induced hardening effects. As a result, it is evident that the compressive stent stress configuration is important to be considered in the computational modeling approaches of stent deployment.
Collapse
|
2
|
Sakellarios AI, Siogkas P, Kigka V, Tsompou P, Pleouras D, Kyriakidis S, Karanasiou G, Pelosi G, Nikopoulos S, Naka KK, Rocchiccioli S, Michalis LK, Fotiadis DI. Error Propagation in the Simulation of Atherosclerotic Plaque Growth and the Prediction of Atherosclerotic Disease Progression. Diagnostics (Basel) 2021; 11:diagnostics11122306. [PMID: 34943545 PMCID: PMC8699876 DOI: 10.3390/diagnostics11122306] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2021] [Revised: 11/23/2021] [Accepted: 12/06/2021] [Indexed: 11/16/2022] Open
Abstract
Assessments of coronary artery disease can be achieved using non-invasive computed tomography coronary angiography (CTCA). CTCA can be further used for the 3D reconstruction of the coronary arteries and the development of computational models. However, image acquisition and arterial reconstruction introduce an error which can be propagated, affecting the computational results and the accuracy of diagnostic and prognostic models. In this work, we investigate the effect of an imaging error, propagated to a diagnostic index calculated using computational modelling of blood flow and then to prognostic models based on plaque growth modelling or binary logistic predictive modelling. The analysis was performed utilizing data from 20 patients collected at two time points with interscan period of six years. The collected data includes clinical and risk factors, biological and biohumoral data, and CTCA imaging. The results demonstrated that the error propagated and may have significantly affected some of the final outcomes. The calculated propagated error seemed to be minor for shear stress, but was major for some variables of the plaque growth model. In parallel, in the current analysis SmartFFR was not considerably affected, with the limitation of only one case located into the gray zone.
Collapse
Affiliation(s)
- Antonis I. Sakellarios
- Department of Biomedical Research, Institute of Molecular Biology and Biotechnology—FORTH, University Campus of Ioannina, 45110 Ioannina, Greece; (P.S.); (V.K.); (P.T.); (S.K.); (G.K.); (D.I.F.)
- Unit of Medical Technology and Intelligent Information Systems, Department of Materials Science and Engineering, University of Ioannina, 45110 Ioannina, Greece;
- Correspondence: ; Tel.: +30-265-100-7837
| | - Panagiotis Siogkas
- Department of Biomedical Research, Institute of Molecular Biology and Biotechnology—FORTH, University Campus of Ioannina, 45110 Ioannina, Greece; (P.S.); (V.K.); (P.T.); (S.K.); (G.K.); (D.I.F.)
- Unit of Medical Technology and Intelligent Information Systems, Department of Materials Science and Engineering, University of Ioannina, 45110 Ioannina, Greece;
| | - Vassiliki Kigka
- Department of Biomedical Research, Institute of Molecular Biology and Biotechnology—FORTH, University Campus of Ioannina, 45110 Ioannina, Greece; (P.S.); (V.K.); (P.T.); (S.K.); (G.K.); (D.I.F.)
- Unit of Medical Technology and Intelligent Information Systems, Department of Materials Science and Engineering, University of Ioannina, 45110 Ioannina, Greece;
| | - Panagiota Tsompou
- Department of Biomedical Research, Institute of Molecular Biology and Biotechnology—FORTH, University Campus of Ioannina, 45110 Ioannina, Greece; (P.S.); (V.K.); (P.T.); (S.K.); (G.K.); (D.I.F.)
- Unit of Medical Technology and Intelligent Information Systems, Department of Materials Science and Engineering, University of Ioannina, 45110 Ioannina, Greece;
| | - Dimitrios Pleouras
- Unit of Medical Technology and Intelligent Information Systems, Department of Materials Science and Engineering, University of Ioannina, 45110 Ioannina, Greece;
| | - Savvas Kyriakidis
- Department of Biomedical Research, Institute of Molecular Biology and Biotechnology—FORTH, University Campus of Ioannina, 45110 Ioannina, Greece; (P.S.); (V.K.); (P.T.); (S.K.); (G.K.); (D.I.F.)
| | - Georgia Karanasiou
- Department of Biomedical Research, Institute of Molecular Biology and Biotechnology—FORTH, University Campus of Ioannina, 45110 Ioannina, Greece; (P.S.); (V.K.); (P.T.); (S.K.); (G.K.); (D.I.F.)
- Unit of Medical Technology and Intelligent Information Systems, Department of Materials Science and Engineering, University of Ioannina, 45110 Ioannina, Greece;
| | - Gualtiero Pelosi
- Institute of Clinical Physiology, National Research Council, 56124 Pisa, Italy; (G.P.); (S.R.)
| | - Sotirios Nikopoulos
- Department of Cardiology, Medical School, University of Ioannina, 45110 Ioannina, Greece; (S.N.); (K.K.N.); (L.K.M.)
| | - Katerina K. Naka
- Department of Cardiology, Medical School, University of Ioannina, 45110 Ioannina, Greece; (S.N.); (K.K.N.); (L.K.M.)
| | - Silvia Rocchiccioli
- Institute of Clinical Physiology, National Research Council, 56124 Pisa, Italy; (G.P.); (S.R.)
| | - Lampros K. Michalis
- Department of Cardiology, Medical School, University of Ioannina, 45110 Ioannina, Greece; (S.N.); (K.K.N.); (L.K.M.)
| | - Dimitrios I. Fotiadis
- Department of Biomedical Research, Institute of Molecular Biology and Biotechnology—FORTH, University Campus of Ioannina, 45110 Ioannina, Greece; (P.S.); (V.K.); (P.T.); (S.K.); (G.K.); (D.I.F.)
- Unit of Medical Technology and Intelligent Information Systems, Department of Materials Science and Engineering, University of Ioannina, 45110 Ioannina, Greece;
| |
Collapse
|
3
|
Loukas VS, Karanasiou GS, Pleouras D, Kyriakidis S, Sakellarios AI, Semertzioglou A, Michalis LK, Fotiadis DI. Investigation of Drug Eluting Stents performance in human atherosclerotic artery through in silico modeling. Annu Int Conf IEEE Eng Med Biol Soc 2021; 2021:5433-5436. [PMID: 34892355 DOI: 10.1109/embc46164.2021.9629895] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Atherosclerosis is a chronic inflammatory disease associated with heart attack and stroke. It causes the growth of atherosclerotic plaques inside the arterial vessels, which in turn results to the reduction of the blood flow to the different organs. Drug-Eluting Stents (DES) are mesh-like wires, carrying pharmaceutical coating, designed to dilate and support the arterial vessel, restore blood flow and through the controlled local drug delivery inhibit neo-intimal thickening. In silico modeling is an efficient method of accurately predicting and assessing the performance of the stenting procedure. The present in silico study investigates the performance of two different stents (Bare Metal Stent, Drug-Eluting Stent) in a patient-specific coronary artery and assesses the effect of stent coating, considering that the same procedural approach is followed by the interventional cardiologist. The results demonstrate that even if small differences are obtained in the two models, the incorporation of the stent coatings (in DES) does not significantly affect the outcomes of the stent deployment, the stresses and strains in the scaffold and the arterial tissue. Nevertheless, it is suggested that regarding the DES expansion, higher pressure should be applied at the inner surface of the stent.
Collapse
|
4
|
Pleouras D, Sakellarios A, Rigas G, Karanasiou GS, Tsompou P, Karanasiou G, Kigka V, Kyriakidis S, Pezoulas V, Gois G, Tachos N, Ramos A, Pelosi G, Rocchiccioli S, Michalis L, Fotiadis DI. A Novel Approach to Generate a Virtual Population of Human Coronary Arteries for In Silico Clinical Trials of Stent Design. IEEE Open J Eng Med Biol 2021; 2:201-209. [PMID: 35402969 PMCID: PMC8901009 DOI: 10.1109/ojemb.2021.3082328] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Revised: 05/06/2021] [Accepted: 05/17/2021] [Indexed: 11/15/2022] Open
Abstract
Goal: To develop a cardiovascular virtual population using statistical modeling and computational biomechanics. Methods: A clinical data augmentation algorithm is implemented to efficiently generate virtual clinical data using a real clinical dataset. An atherosclerotic plaque growth model is employed to 3D reconstructed coronary arterial segments to generate virtual coronary arterial geometries (geometrical data). Last, the combination of the virtual clinical and geometrical data is achieved using a methodology that allows for the generation of a realistic virtual population which can be used in in silico clinical trials. Results: The results show good agreement between real and virtual clinical data presenting a mean gof 0.1 ± 0.08. 400 virtual coronary arteries were generated, while the final virtual population includes 10,000 patients. Conclusions: The virtual arterial geometries are efficiently matched to the generated clinical data, both increasing and complementing the variability of the virtual population.
Collapse
Affiliation(s)
| | - Antonis Sakellarios
- Department of Biomedical ResearchFORTH-IMBB GR 45110 Ioannina Greece
- Unit of Medical Technology and Intelligent Information Systems, Department of Materials Science and EngineeringUniversity of Ioannina GR 45110 Greece
| | - George Rigas
- Unit of Medical Technology and Intelligent Information Systems, Department of Materials Science and EngineeringUniversity of Ioannina GR 45110 Greece
| | | | - Panagiota Tsompou
- Unit of Medical Technology and Intelligent Information Systems, Department of Materials Science and EngineeringUniversity of Ioannina GR 45110 Greece
| | - Gianna Karanasiou
- Department of Biomedical ResearchFORTH-IMBB GR 45110 Ioannina Greece
| | - Vassiliki Kigka
- Unit of Medical Technology and Intelligent Information Systems, Department of Materials Science and EngineeringUniversity of Ioannina GR 45110 Greece
| | - Savvas Kyriakidis
- Department of Biomedical ResearchFORTH-IMBB GR 45110 Ioannina Greece
| | - Vasileios Pezoulas
- Unit of Medical Technology and Intelligent Information Systems, Department of Materials Science and EngineeringUniversity of Ioannina GR 45110 Greece
| | - George Gois
- Department of Biomedical ResearchFORTH-IMBB GR 45110 Ioannina Greece
| | - Nikolaos Tachos
- Department of Biomedical ResearchFORTH-IMBB GR 45110 Ioannina Greece
| | - Aidonis Ramos
- Department of Cardiology, Medical SchoolUniversity of Ioannina Ioannina GR 45110 Greece
| | - Gualtiero Pelosi
- Institute of Clinical PhysiologyNational Research Council 56124 Pisa Italy
| | | | - Lampros Michalis
- Department of Cardiology, Medical SchoolUniversity of Ioannina Ioannina GR 45110 Greece
| | - Dimitrios I Fotiadis
- Department of Biomedical ResearchFORTH-IMBB GR 45110 Ioannina Greece
- Unit of Medical Technology and Intelligent Information Systems, Department of Materials Science and EngineeringUniversity of Ioannina GR 45110 Greece
| |
Collapse
|
5
|
Pleouras D, Rocchiccioli S, Pelosi G, Michalis LK, Fotiadis DI, Sakellarios AI, Kyriakidis S, Kigka V, Siogkas P, Tsompou P, Tachos N, Georga E, Andrikos I. A computational multi-level atherosclerotic plaque growth model for coronary arteries. Annu Int Conf IEEE Eng Med Biol Soc 2020; 2019:5010-5013. [PMID: 31946985 DOI: 10.1109/embc.2019.8857329] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
In this work, we present a novel computational approach for the prediction of atherosclerotic plaque growth. In particular, patient-specific coronary computed tomography angiography (CCTA) data were collected from 60 patients at two time points. Additionally, blood samples were collected for biochemical analysis. The CCTA data were used for 3D reconstruction of the coronary arteries, which were then used for computational modeling of plaque growth. The model of plaque growth is based on a multi-level approach: i) the blood flow is modeled in the lumen and the arterial wall, ii) the low and high density lipoprotein and monocytes transport is included, and iii) the major atherosclerotic processes are modeled including the foam cells formation, the proliferation of smooth muscle cells and the formation of atherosclerotic plaque. Validation of the model was performed using the follow-up CCTA. The results show a correlation of the simulated follow-up arterial wall area to be correlated with the corresponding realistic follow-up with r2=0.49, P<; 0.0001.
Collapse
|